Switch Specifications
Description |
Specification |
---|---|
Temperature, ambient operating |
32 to 104°F (0 to 40°C) |
Temperature, ambient nonoperating and storage |
-40 to 158°F (-40 to 70°C) |
Humidity (RH), ambient (noncondensing) operating |
10 to 90% |
Humidity (RH), ambient (noncondensing) nonoperating and storage |
5 to 95% |
Altitude, operating |
-197 to 6500 ft (-60 to 2000 m) |
Noise levels |
60 dB |
Description |
Specification |
---|---|
Cisco MDS 9396S Switch Dimensions |
Width = 17.16 inch (43.59 cm) Height = 1.72 inch (4.37 cm) Depth = 16.34 inch (41.50 cm) |
Rack Unit (RU) |
Chassis requires 2 RU (1.75 in. or 4.45 cm) |
Weight |
19.84 lb (9 kg) (with two fan modules and two power supplies installed) |
Power Supply |
1200 W with 180-264 VAC input; 800 W with 90-180 VAC input Part Number: DS-CAC-1200W-E Power cord: Notched C13 socket connector connecting to C14 plug on power supply 100 to 240V AC (10% range) 50 to 60 Hz (nominal) |
Airflow |
Port side exhausted. 110 linear feet per minute (LFM) through the system and a maximum of 255 LMDM. Cisco recommends that you maintain a minimum air space of 2.5 in. (6.4 cm) between walls and chassis air vents and a minimum horizontal separation of 6 in. (15.2 cm) between two chassis to prevent overheating. |