Server Specifications

This chapter lists the physical, environmental, and power specifications for the server.

Physical Specifications

The following table lists the physical specifications for the server.

Table 1. Physical Specifications

Description

Specification

Height

1.7 in. (43.2 mm)

Width

16.9 in. (429.0 mm)

Depth (length)

Server only: 30 in. (762 mm)

Server with slide rail: 31.5 in (800.1 mm)

Weight

  • Maximum: 42.432 lb (19.25 kg)

  • Minimum: 22.32 lb (10.13 kg)

Environmental Specifications

The following table lists the environmental requirements and specifications for the server.

Table 2. Environmental Specifications

Description

Specification

Temperature, Operating

Dry bulb temperature of 10°C to 35°C (50°F to 95°F)

Derate the maximum temperature by 1°C (33.8°F) every 305 meters of altitude above 900 m

Temperature, Extended Operating

5°C to 40°C (41°F to 104°F) with no direct sunlight

Derate the maximum temperature by 1°C (33.8°F) every 305 meters of altitude above 900 m

Temperature, non-operating (when the server is stored or transported)

Dry bulb temperature of 40 °C to 65 °C (-40°F to 149 °F)

Humidity (RH), operating

10% to 90% and 28°C (82.4°F) maximum dew-point temperature, noncondensing environment

Minimum to be higher (more moisture) of -12 ˚C (10.4 ˚F) dew point or 8% relative humidity

Maximum to be 24 ˚C (75.2 ˚F) dew point or 90% relative humidity

Humidity (RH), non-operating

5% to 93% relative humidity, noncondensing, with a maximum wet bulb temperature of 28 °C across the 20 °C to 40 °C dry bulb range.

Altitude, operating

A maximum elevation of 3050 meters (10,006 feet)

Altitude, non-operating

An elevation of 0 to 12,000 meters (39,370 feet)

Maximum Operating Duration

Unlimited

Sound power level

Measure A-weighted per ISO7779 LwAd (Bels)

Operation at 73°F (23°C)

5.5

Sound pressure level

Measure A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

40

Power Specifications


Note


Do not mix power supply types or wattages in the server. Both power supplies must be identical.

The power specifications for the supported power supply options are listed in the following sections.

1050-W V2 DC Power Supply

This table lists the specifications for 1050-W V2 DC power supply.

Parameter

Specification

Input Connector

Molex 42820

Input Voltage Range (V rms)

-48

Maximum Allowable Input Voltage Range (V rms)

-40 to -72

Frequency Range (Hz)

NA

Maximum Allowable Frequency Range (Hz)

NA

Maximum Rated Output (W)

1050

Maximum Rated Standby Output (W)

36

Nominal Input Voltage (V rms)

-48

Nominal Input Current (A rms)

24

Maximum Input at Nominal Input Voltage (W)

1154

Maximum Input at Nominal Input Voltage (VA)

1154

Maximum Rated Efficiency (%)

Minimum rating required to achieve 80PLUS platinum certification.

91

Maximum Rated Power Factor

Minimum rating required to achieve 80PLUS platinum certification.

NA

Maximum Inrush Current (peak A)

15

Maximum Inrush Current (ms)

0.2

Maximum Ride-Through Time

This is the duration for which output voltage remains within regulation limits at 100% load, during input voltage dropout.

5

1050-W AC Power Supply

This table lists the specifications for each 1050-W AC power supply.

Parameter

Specification

Input Connector

IEC320 C14

Input Voltage Range (V rms)

100 to 240

Maximum Allowable Input Voltage Range (V rms)

90 to 264

Frequency Range (Hz)

50 to 60

Maximum Allowable Frequency Range (Hz)

47 to 63

Maximum Rated Output (W)

Limited to 800 W when operating at low-line input voltage, 100-127 V

1050

Maximum Rated Standby Output (W)

36

Nominal Input Voltage (V rms)

230

Nominal Input Current (A rms)

5.2

Maximum Input at Nominal Input Voltage (W)

1154

Maximum Input at Nominal Input Voltage (VA)

1190

Maximum Rated Efficiency (%)

Minimum rating required to achieve 80PLUS platinum certification.

90

Maximum Rated Power Factor

Minimum rating required to achieve 80PLUS platinum certification.

0.97

Maximum Inrush Current (peak A)

15

Maximum Inrush Current (ms)

0.2

Maximum Ride-Through Time

Time output voltage remains within regulation limits at 100% load, during input voltage dropout

12

Power Cord Specifications

Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the appliance. The shorter jumper power cords that are used in racks are available as an optional alternative to the standard power cords.


Note


Only the approved power cords or jumper power cords listed below are supported.


Table 3. Supported Power Cords

Description

Length (Feet)

Length (Meters)

CAB-48DC-40A-8AWG

DC power cord, -48 VDC, 40 A, 8 AWG

Three-socket mini-fit connector to three-wire

11.7

3.5

CAB-C13-C14-AC

AC power cord, 10 A; C13 to C14, recessed receptacle

9.8

3.0

CAB-250V-10A-AR

AC power cord, 250 V, 10 A

Argentina

8.2

2.5

CAB-C13-C14-2M-JP

AC Power Cord, C13 to C14

Japan PSE Mark

6.6

2.0

CAB-9K10A-EU

AC Power Cord, 250 V, 10 A, CEE 7/7 Plug

Europe

8.2

2.5

CAB-250V-10A-IS

AC Power Cord, SFS, 250 V, 10 A

Israel

8.2

2.5

CAB-250V-10A-CN

AC power cord, 250 V, 10 A

PR China

8.2

2.5

CAB-ACTW

AC power cord, 250 V, 10 A, C13 EL302

Taiwan

7.5

2.3

CAB-C13-CBN

AC cabinet jumper power cord, 250 V, 10 A,

C13 to C14

2.2

0.68

CAB-C13-C14-2M

AC cabinet jumper power cord, 250 V, 10 A,

C13 to C14

6.6

2.0

CAB-9K10A-AU

AC power cord, 250 V, 10 A, 3112 plug,

Australia

8.2

2.5

CAB-N5K6A-NA

AC power cord, 200/240 V, 6 A,

North America

8.2

2.5

CAB-250V-10A-ID

AC power Cord, 250 V, 10 A,

India

8.2

2.5

CAB-9K10A-SW

AC power cord, 250 V, 10 A, MP232 plug

Switzerland

8.2

2.5

CAB-250V-10A-BR

AC power Cord, 250 V, 10 A

Brazil

8.2

2.5

CAB-9K10A-UK

AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug

United Kingdom

8.2

2.5

CAB-9K12A-NA

AC power cord, 125 V, 13 A, NEMA 5-15 plug

North America

8.2

2.5

CAB-AC-L620-C13

AC power cord, NEMA L6-20 to C13 connectors

6.6

2.0

CAB-9K10A-IT

AC power cord, 250 V, 10 A, CEI 23-16/VII plug

Italy

8.2

2.5

CAB-C13-C14-3M-IN

AC power cord jumper, C13 to C14 connector

India

9.8

3.0

CAB-C13-C14-IN

AC power cord jumper, C13 to C14 connector

India

4.6

1.4

CAB-9K10A-KOR

Power Cord, 125 V AC, 13 A, KSC8305 plug

Korea

6

1.8

CAB-JPN-3PIN

90-125 V AC, 12 A, NEMA 5-15 plug

Japan

2.4

R2XX-DMYMPWRCORD

No power cord; PID option for ordering server with no power cord

NA

NA