OSMINE Layout Rules

In this appendix, “OPT-BST” refers to the OPT-BST, OPT-BST-E, OPT-BST-L cards, and to the OPT-AMP-L and OPT-AMP-17-C cards when they are provisioned in OPT-LINE (optical booster) mode. “OPT-PRE” refers to the OPT-PRE card and to the OPT-AMP-L and OPT-AMP-17-C cards provisioned in OPT-PRE (preamplifier) mode.

OSMINE Layout Rules for Software Release 9.2.1

The following table lists the OSMINE layout rules for various configurations and their card placements for Software Release 9.2.1.

Note


15454-40-DMX-C and 15454-40-MUX-C is EOL. For an update on End-of-Life and End-of-Sale PIDs, see EOL and EOS PIDs.


Table 1. OSMINE Layout Rules for Software Release 9.2.1

Configuration

Card Placement

Condition

Hub node 32 channel (100GHz)

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —32 MUX-OS

lot 5 and 6 —32 DMX-O

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 and 13 —32 DMX-O

Slot 14 and 15 —32 MUX-O

Slot 16 —Pre

Slot 17 —Booster (A)

Node containing the following:

  • pre and booster units.

  • 32-channel MUX-O and 32-channel DMX-O units.

OADM node

Slot 1 —Booster

Slot 2 —Pre

Slot 3 —AD-xC

Slot 4 —AD-xC

Slot 5 —AD-xC

Slot 6 —MS-ISC

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —MS-ISC

Slot 13 —AD-xC

Slot 14 —AD-xC

Slot 15 —AD-xC

Slot 16 —Pre

Slot 17 —Booster (A)

Nodes:

  • containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

Line Amplifier mode

Slot 1 —Booster

Slot 2 —Pre

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —BLANK

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —BLANK

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —Pre

Slot 17 —Booster (A)

Nodes:

  • containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

Line Site with OPT-RAMP-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —BLANK or TXP

Slot 5 —BLANK or TXP

Slot 6 —BLANK or TXP

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —BLANK or TXP

Slot 13 —BLANK or TXP

Slot 14 —BLANK or TXP

Slot 15 —Booster

Slot 16 and 17 —OPT-RAMP-C

Nodes:

  • containing pre units.

  • not containing booster units.

OSC Regenerator site

Slot 1 —OSC-CSM

Slot 2 —BLANK

Slot 3 —BLANKSlot 4 —BLANK

Slot 5 —BLANK

Slot 6 —BLANK

Slot 7 —TCC2P

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2P

Slot 12 —BLANK

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —OSC-CSM

Nodes not containing pre and booster units

32 channel ROADM/Hub node

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —32-WSS

Slot 5 —32-DMX

Slot 6 —MS-ISC

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —MS-ISC

Slot 13 —32-DMX

Slot 14 and 15 —32-WSS

Slot 16 —Pre

Slot 17 —Booster

Nodes containing pre and booster units.

40 channel ROADM/Hub node

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WSS

Slot 5 —40-DMX

Slot 6 —MS-ISC

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —MS-ISC

Slot 13 —40-DMX

Slot 14 and 15 —40-WSS

Slot 16 —Pre

Slot 17 —Booster

Nodes containing pre and booster units.

40 channel HUB/ROADM with OPT-RAMP-C

NC shelf

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —Pre

Slot 5 —BLANK or TXP

Slot 6 —MS-ISC-100T

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC-100T

Slot 13 —40-DMX

Slot 14 and 15 —40-WSS

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

  • OPT-RAMP-C or OPT-RAMP-CE on both sides.

  • OPT-RAMP-CE can replace OPT-RAMP-C cards.

Subtended Opt shelf

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —Pre

Slot 5 —BLANK or TXP

Slot 6 —BLANK or TXP

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —BLANK or TXP

Slot 13 —40-DMX

Slot 14 and 15 —40-WSS

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

40 channel HUB/ROADM with OPT-RAMP-C

NC shelf

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —Pre

Slot 5 —BLANK or TXP

Slot 6 —MS-ISC-100T

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC-100T

Slot 13 —40-DMX

Slot 14 and 15 —40-WSS

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

  • OPT-RAMP-C or OPT-RAMP-CE on one side only.

  • OPT-RAMP-CE can replace OPT-RAMP-C.

Subtended shelf

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WSS

Slot 5 —40-DMX

Slot 6 —BLANK or TXP

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —BLANK or TXP

Slot 13 —BLANK or TXP

Slot 14 —BLANK or TXP

Slot 15 —BLANK or TXP

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

40 channel HUB with 40-MUX-C

Slot 1 —Booster

Slot 2 —Pre

Slot 3 —40-DMX-C

Slot 4 —40-MUX-C

Slot 5 —BLANK or TXPs

Slot 6 —MS-ISC

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —MS-ISC

Slot 13 —BLANK or TXPs

Slot 14 —40-MUX-C

Slot 15 —40-DMX-C

Slot 16 —Pre

Slot 17 —Booster

Nodes containing pre and booster units.

32 channel Terminal Site (Half of Hub node)

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —32-WSS

Slot 5 —32-DMX

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

Nodes containing pre and booster units.

40 channel Terminal Site (Half of Hub node)

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WSS

Slot 5 —40-DMX

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

Nodes containing pre and booster units.

40 channel Terminal Site with OPT-RAMP-C

NC shelf

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —Pre

Slot 5 —BLANK or TXP

Slot 6 —MS-ISC-100T

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC-100T

Slot 13 —40-DMX

Slot 14 and 15 —40-WSS

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

Nodes containing pre and booster units.

40 channel Terminal Site with 40-MUX-C (Half Hub)

Slot 1 —Booster

Slot 2 —Pre

Slot 3 —40-DMX-C

Slot 4 —40-MUX-C

Slot 5 —BLANK or TXPs

Slot 6 —MS-ISC

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2P

Slot 12 —MS-ISC

Slot 13 —BLANK or TXPs

Slot 14 —BLANK or TXPs

Slot 15 —BLANK or TXPs

Slot 16 —BLANK or TXPs

Slot 17 —BLANK or TXPs

Nodes containing pre and booster units.

32 channel Gain Equalizer

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —32-WSS

Slot 5 —BLANK or TXPs

Slot 6 —BLANK or TXPs

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —BLANK or TXPs

Slot 13 —BLANK or TXPs

Slot 14 and 15 —32-WSS

Slot 16 —Pre

Slot 17 —Booster

Nodes containing pre and booster units.

40 channel Gain Equalizer with OPT-RAMP-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 and 5 —40-WSS-C

Slot 6 —BLANK

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —BLANK

Slot 13 and 14 —40-WSS-C

Slot 15 —Booster

Slot 16 and 17 —OPT-RAMP-C

Nodes:

  • not containing pre units.

  • containing booster units.

40 channel n-degree ROADM—Optical shelf

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WXC-C

Slot 5 —40-MUX-C

Slot 6 —40-DMX-C

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —40-DMX-C

Slot 13 —40-MUX-C

Slot 14 and 15 —40-WXC-C

Slot 16 —Pre

Slot 17 —Booster

Nodes containing pre and booster units.

40 channel 4-degree ROADM

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WXC-C

Slot 5 —40-MUX-C

Slot 6 —40-DMX-C

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —40-DMX-C

Slot 13 —40-MUX-C

Slot 14 and 15 —40-WXC-C

Slot 16 —Pre

Slot 17 —Booster

  • Maximum 30 shelves.

  • Nodes containing pre and booster units.

40 channel 8-degree ROADM (Maximum 30 shelves)

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WXC-C

Slot 5 —40-MUX-C

Slot 6 —40-DMX-C

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —40-DMX-C

Slot 13 —40-MUX-C

Slot 14 and 15 —40-WXC-C

Slot 16 —Pre

Slot 17 —Booster

Nodes containing pre and booster units.

n degree ROADM with OPT-RAMP-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —Pre

Slot 5 —BLANK or TXP

Slot 6 —MS-ISC-100T

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC-100T

Slot 13 —40-DMX-C

Slot 14 —40-MUX-C

Slot 15 and 16 —40-WXC-C

Slot 17 —BLANK or TXP

  • MS-ISC-100T is optional.

  • NC shelf.

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —Pre

Slot 5 —BLANK or TXP

Slot 6 —BLANK or TXP

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —BLANK or TXP

Slot 13 —40-DMX-C

Slot 14 —40-MUX-C

Slot 15 and 16 —40-WXC-C

Slot 17 —BLANK or TXP

  • MS-ISC-100T is optional.

  • Subtended ROADM shelf with OPT-RAMP-C or OPT-RAMP-CE.

Slot 1 —BLANK or TXP

Slot 2 —BLANK or TXP

Slot 3 —BLANK or TXP

Slot 4 —BLANK or TXP

Slot 5 —BLANK or TXP

Slot 6 —BLANK or TXP

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —BLANK or TXP

Slot 13 —BLANK or TXP

Slot 14 —BLANK or TXP

Slot 15 —BLANK or TXP

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

  • Subtended TXP shelf.

  • Nodes not containing pre and booster units.

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —40-WXC-C

Slot 5 —40-MUX-C

Slot 6 —40-DMX-C

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —40-MUX-C

Slot 13 —40-DMX-C

Slot 14 and 15 —40-WXC-C

Slot 16 —Pre

Slot 17 —Booster

  • Subtended ROADM shelf without OPT-RAMP-C or OPT-RAMP-CE.

  • Nodes containing pre and booster units.

PSM channel Protection

TXP shelf (Sample 1)

Slot 1 —PSM

Slot 2 —TXP

Slot 3 —PSM

Slot 4 —TXP

Slot 5 —PSM

Slot 6 —TXP

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —PSM

Slot 13 —TXP

Slot 14 —PSM

Slot 15 —TXP

Slot 16 —PSM

Slot 17 —TXP

  • TXP can be one slot or two slot.

  • Focus on 10-DME, 10-DMEX, 4x2.5 MUXP, and 40G.

TXP shelf (Sample 2)

Slot 1 —PSM

Slot 2 and 3 —TXP

Slot 4 —PSM

Slot 5 and 6 —TXP

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —PSM

Slot 13 —TXP

Slot 14 —PSM

Slot 15 —TXP

Slot 16 —PSM

Slot 17 —TXP

40 channel ROADM/ HUB—40-SMR1-C

Sh1 - Option 1

Slot 1 —Booster

Slot 2 —40-SMR1-C

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —40-SMR1-C

Slot 17 —Booster

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

Sh1 - Option 2

Slot 1 —40-SMR1-C

Slot 2 —BLANK

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —40-SMR1-C

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel ROADM/HUB—40- SMR1-C

Slot 1 —40-SMR2-C

Slot 2 —BLANK

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —40-SMR2-C

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel ROADM/HUB with OPT-RAMP-C – 40-SMR1-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —40-SMR1-C

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —40-SMR1-C

Slot 15 —Booster

Slot 16 and 17 —OPT-RAMP-C

Nodes:

  • not containing pre units.

  • containing booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel Terminal Site—40-SMR1-C

Shelf 1 - Option A

Slot 1 —Booster

Slot 2 —40-SMR1-C

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

Nodes:

  • not containing pre units.

  • containing booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

Shelf 1 - Option B

Slot 1 —40-SMR1-C

Slot 2 —BLANK

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel Terminal Site—40-SMR2-C

Shelf 1 - Option C

Slot 1 —40-SMR2-C

Slot 2 —BLANK

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel Terminal Site with OPT-RAMP-C – 40-SMR1-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —40-SMR1-C

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

Nodes:

  • not containing pre units.

  • containing booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel 4-degree ROADM—40-SMR 1-C

Slot 1 —40-SMR2-C

Slot 2 —40-SMR2-C

Slot 3 —OSC-CSM

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —OSC-CSM

Slot 16 —40-SMR2-C

Slot 17 —40-SMR2-C

  • This 4-degree node may also be configured with the 4-degrees spanning two, three, or four shelves.

  • 40-SMR1-C and OSC-CSM are supported only for management supervisory channel capability.

40 channel Gain Equalizer— 40-SMR1-C

Option A

Slot 1 —Booster

Slot 2 —40-SMR1-C

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —40-SMR1-C

Slot 17 —Booster

Nodes:

  • not containing pre.

  • containing booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

Option B

Slot 1 —40-SMR1-C

Slot 2 —BLANK

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —40-SMR1-C

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

Option C

Slot 1 —40-SMR2-C

Slot 2 —BLANK

Slot 3 —BLANK

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —40-SMR2-C

Nodes:

  • not containing pre and booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel Gain Equalizer with OPT-RAMP-C – 40-SMR1-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —Booster

Slot 4 —40-SMR1-C

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —40-SMR1-C

Slot 15 —Booster

Slot 16 and 17 —OPT-RAMP-C

Nodes:

  • not containing pre units.

  • containing booster units.

  • not containing 32-channel MUX-O and 32-channel DMX-O units.

40 channel n-degree ROADM — omnidirectional colored side

Slot 1 —40-MUX-C

Slot 2 —40-DMX-C

Slot 3 —Pre

Slot 4 —Pre

Slot 5 and 6 —40-WXC-C

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —Any Other Side

Slot 11 —TCC2

Slot 12 —Any Other Side

Slot 13 —Any Other Side

Slot 14 —Any Other Side

Slot 15 —Any Other Side

Slot 16 —Any Other Side

Slot 17 —Any Other Side

Any other side can equip another omnidirectional side:

  • Slot 12 and 13: 40-WXC-C

  • Slot 14: Pre

  • Slot 15: Pre

  • slot 16: DMX

  • slot 17: MUX

40 channel colorless terminal site configuration

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —80-WXC-C

Slot 5 and 6 —80-WXC-C

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2P

Slot 12 and 13 —80-WXC-C

Slot 14 and 15 —80-WXC-C

Slot 16 —BLANK

Slot 17 —BLANK

Slot 16 can equip 40-DMX and slot 17 can equip 40-MUX to replace passive Odd (MD-40-ODD). They are connected to L1 MUX/DMX (port EAD 1).

WXC Role:

  • Slot 3: L1 MUX

  • Slot 5: L1 DMX

  • Slot 12: L2 MUX

  • Slot 14: L2 DMX

40 channel n-degree ROADM—WXC - colorless side

Slot 1 —Booster

Slot 2 —Pre

Slot 3 and 4 —80-WXC-C

Slot 5 and 6 —80-WXC-C

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2P

Slot 12 and 13 —40-WXC-C

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

  • 80 WXC is connected to the Add/Drop port of the 40-WXC-C card as a colorless MUX and DMX.

  • Add and drops ports from the 80-WXC-C can be OCH or OMS.

40 channel n-degree ROADM-colorless and omnidirectional side

Slot 1 and 2 —80-WXC-C

Slot 3 and 4 —80-WXC-C

Slot 5 —Pre

Slot 6 —Pre

Slot 7 —TCC2P

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2P

Slot 12 and 13 —40-WXC-C

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —BLANK

Slot 17 —BLANK

  • Passive MD can be subtended to L1 MUX/DMX.

  • 80 WXC are connected to the pre amplifiers as colorless omnidirectional MUX and DMX.

  • Add and drop ports from the 80-WXC-C can be OCH or OMS.

WXC Role:

  • Slot 1: MUX

  • Slot 3: DMX

Additional cards:

  • Slot 14: MUX to extend add ports > 9.

  • Slot 16: DMX to extend drop ports > 9.

40 channel–non DWDM

Standalone shelf

Slot 1 —Booster or TXP

Slot 2 —BLANK or Pre or Booster TXP

Slot 3 —BLANK or Pre or Booster TXP

Slot 4 —BLANK or Pre or Booster TXP

Slot 5 —BLANK or Pre or Booster TXP

Slot 6 —BLANK or Pre or Booster TXP

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —BLANK or Pre or Booster TXP

Slot 13 —BLANK or Pre or Booster TXPSlot 14 —BLANK or Pre or Booster TXP

Slot 15 —BLANK or Pre or Booster TXP

Slot 16 —BLANK or Pre or Booster TXP

Slot 17 —Booster or TXP

Standalone transponder shelves can be added.

40 channel n-degree ROADM – 40-SMR2-C – Two- colored omnidirectional side

Slot 1 —BLANK

Slot 2 —BLANK

Slot 3 —40-SMR2-C

Slot 4 —40-SMR2-C

Slot 5 —BLANK

Slot 6 —BLANK

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —BLANK

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —BLANK

Slot 16 —40-SMR2-C

Slot 17 —40-SMR2-C

  • 40-SMR2-C cards in slot 3 and 4 are connected to passive omnidirectional MUX/DMX.

  • Optical safety must be disabled on 40-SMR2-C in slot 3 and 4.

40 channel n-degree ROADM— 40-SMR2-C–Single- colorless omnidirectional side

Slot 1—BLANK

Slot 2 and 3 —80-WXC-C

Slot 4 and 5 —80-WXC-C

Slot 6 —40-SMR2-C

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —OSC-CSM

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —40-SMR2-C

Slot 16 —40-SMR2-C

Slot 17 —40-SMR2-C

  • Additional shelf with 80-WXC-C cards to extend Add and Drop ports > 9 (to equip L2 MUX and DMX).

  • 80 WXC are connected to the Line ports of the 40-SMR2 cards in slot 5 as colorless omnidirectional MUX and DMX.

  • Optical safety of the 40-SMR2 cards in Slot 5 must be disabled.

WXC Role:

  • Slot 2: L1 MUX

  • Slot 4: L1 DMX

40 channel 4-degree ROADM – 40-SMR2-C –colorless side

Slot 1 —40-SMR2-C

Slot 2 and 3 —80-WXC-C

Slot 4 and 5 —80-WXC-C

Slot 6 —BLANK

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —Any Other Side

Slot 11 —TCC2P

Slot 12 —Any Other Side

Slot 13 —Any Other Side

Slot 14 —Any Other Side

Slot 15 —Any Other Side

Slot 16 —Any Other Side

Slot 17 —Any Other Side

80 WXC are connected to the Add/Drop port of the 40-SMR2 card in slot 1 as colorless MUX and DMX.

WXC Role:

  • Slot 1: MUX

  • Slot 3: DMX

40 channel n-degree ROADM — 40-SMR2-C – two- colorless omnidirectional side chassis

Slot 1 —BLANK

Slot 2 and 3 —80-WXC-C

Slot 4 and 5 —80-WXC-C

Slot 6 —40-SMR2-C

Slot 7 —TCC2P

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2P

Slot 12 —40-SMR2-C

Slot 13 and 14 —80-WXC-C

Slot 15 and 16 —80-WXC-C

Slot 17 —BLANK

WXC Role:

  • Slot 2,15: L1 MUX

  • Slot 3,13: L1 DMX

40 channel ROADM/HUB with OPT-RAMP-C – 40-SMR2-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —40-SMR2-C

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —40-SMR2-C

Slot 16 and 17 —OPT-RAMP-C

  • MS-ISC may or may not be present.

  • Without 15216MD (MD-40-ODD), this layout becomes a gain equalizer.

40 channel 4-degree ROADM with OPT-RAMP-C – 40-SMR2-C

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —40-SMR2-C

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —MS-ISC

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —MS-ISC

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —40-SMR2-C

Slot 16 and 17 —OPT-RAMP-C

NC shelf.

Nodes not containing:

  • pre and booster units.

  • MUX/DMX units.

Slot 1 and 2 —OPT-RAMP-C

Slot 3 —40-SMR2-C

Slot 4 —BLANK

Slot 5 —BLANK

Slot 6 —BLANK

Slot 7 —TCC2

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2

Slot 12 —BLANK

Slot 13 —BLANK

Slot 14 —BLANK

Slot 15 —40-SMR2-C

Slot 16 and 17 —OPT-RAMP-C

Subtended shelf.

Nodes not containing:

  • pre and booster units.

  • MUX/DMX units.

40 channel n-degree ROADM — 40-SMR2-C – 2 Colored omnidirectional side with OPT-RAMP-C or OPT-RAMP-CE

Slot 1 —BLANK

Slot 2 —BLANK

Slot 3 —40-SMR2-C

Slot 4 —40-SMR2-C

Slot 5 —BLANK

Slot 6 —BLANK

Slot 7 —TCC2P

Slot 8 —OSCM

Slot 9 —AIC-I

Slot 10 —OSCM

Slot 11 —TCC2P

Slot 12 —40-SMR2-C

Slot 13 and 14 —OPT-RAMP-C

Slot 15 —40-SMR2-C

Slot 16 and 17 —OPT-RAMP-C

  • 40-SMR2-C in slot 3 and 4 are connected to passive omnidirectional MUX/DMX.

  • Optical safety must be disabled on 40-SMR2-C card in slot 3 and 4.

40 channel–Passive Mux/Demux terminal site

Slot 1 —Booster

Slot 2 —BLANK or Pre or TXP

Slot 3 —BLANK or TXP

Slot 4 —BLANK or TXP

Slot 5 —BLANK or TXP

Slot 6 —BLANK or TXP

Slot 7 —TCC2

Slot 8 —BLANK

Slot 9 —AIC-I

Slot 10 —BLANK

Slot 11 —TCC2

Slot 12 —BLANK or TXP

Slot 13 —BLANK or TXP

Slot 14 —BLANK or TXP

Slot 15 —BLANK or TXP

Slot 16 —BLANK or TXP

Slot 17 —BLANK or TXP

Standalone transponder shelves can be added.

OSMINE Layout Rules for Software Release 9.2.1 and 9.6.0.x

The following table lists the OSMINE layout rules for various configurations and their card placements for Software Release 9.2.1 and 9.6.0.x.

Note


15454-40-DMX-C and 15454-40-MUX-C is EOL. For an update on End-of-Life and End-of-Sale PIDs, see EOL and EOS PIDs.


Table 2. OSMINE Layout Rules for Software Release 9.2.1 and 9.6.0.x

Configuration

Card Placement

Condition

Line Site (M6)

With two amplifiers per side

Slot 8 —TNC

Slot 7 —Booster (B)

Slot 6 —Pre (B)

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —Pre (A)

Slot 2 —Booster (A)

Slot 1 —TNC

Two sides accommodated in one chassis are placed in the order shown.

With one amplifier per side

Slot 8 —TNC

Slot 7 —Amp-C (B)

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —Amp-C (A)

Slot 1 —TNC

Transponder shelf (M6)

Slot 8 —TSC

Slot 7 —TXP

Slot 6 —TXP

Slot 5 —TXP

Slot 4 —TXP

Slot 3 —TXP

Slot 2 —TXP

Slot 1 —TSC

TXP and MXP cards do not have any forcing based on direction or slot placement. Therefore, it follows the same rules as optimized configurations (non OSMINE configurations).

Slot 8 —TSC

Slot 6 and 7 —TXP

Slot 4 and 5 —TXP

Slot 3 and 2 —TXP

Slot 1 —TSC

40 channel ROADM/HUB — 40-SMR1-C - M6

40 channel ROADM/HUB – 40-SMR1-C – M6

Shelf 1—Option A

Slot 8 —TNC

Slot 7 —Booster (B)

Slot 6 —40-SMR1-C

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —40-SMR1-C

Slot 2 —Booster (A)

Slot 1 —TNC

Shelf 1—Option B

Slot 8 —TNC

Slot 7 —40-SMR1-C

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR1-C

Slot 1 —TNC

Shelf 1—Option C

Slot 8 —TNC

Slot 7 —Booster (B)

Slot 6 —40-SMR1-C

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR1-C

Slot 1 —TNC

Shelf 1—Option D

Slot 8 —TNC

Slot 7 —40-SMR2-C

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR2-C

Slot 1 —TNC

40-SMR1-C card configuration in a two-degree 40 channel ROADM/HUB with or without booster units.

40 channel ROADM/HUB — 40-SMR2-C - M6

40 channel Terminal Site – 40-SMR2-C – M6

Shelf 1—Option A

Slot 8 —TNC

Slot 7 —BLANK

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —40-SMR1-C

Slot 2 —Booster (A)

Slot 1 —TNC

40-SMR2-C card configuration in a two-degree 40 channel ROADM/HUB with or without booster units.

Shelf 1—Option B

Slot 8 —TNC

Slot 7 —BLANK

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR1-C

Slot 1 —TNC

Shelf 1—Option C

Slot 8 —TNC

Slot 7 —BLANK

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR2-C

Slot 1 —TNC

40 channel ROADM/HUB — 40-SMR1-C - M6

40 channel Gain Equalizer – 40-SMR1-C (M6)

Option A

Slot 8 —TNC

Slot 7 —Booster (B)

Slot 6 —40-SMR1-C

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —40-SMR1-C

Slot 2 —Booster (A)

Slot 1 —TNC

40-SMR1-C card configuration in a two-degree 40 channel ROADM/HUB with or without booster units.

Option B

Slot 8 —TNC

Slot 7 —40-SMR1-C

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR1-C

Slot 1 —TNC

Option C

Slot 8 —TNC

Slot 7 —40-SMR2-C

Slot 6 —BLANK

Slot 5 —BLANK

Slot 4 —BLANK

Slot 3 —BLANK

Slot 2 —40-SMR2-C

Slot 1 —TNC

Omnidirectional side

40 channel n-degree ROADM–omnidirectional side

Slot 8 —TNCSlot 7 —40-DMX-CSlot 6 —40-MUX-CSlot 5 —PreSlot 4 —PreSlot 3 and 2 —40-WXC-CSlot 1 —TNC

XC card are placed first. All other cards are placed in the default order.

OSMINE Layout Rules for Software Release 9.6.0.x

The following table lists the OSMINE layout rules for various configurations and their card placements for Software Release 9.6.0.x.

Table 3. OSMINE Layout Rules for Software Release 9.6.0.x

Configuration

Card Placement

Condition

80 channel n degree R-OADM with Chianti

n-degree 80 channel ROADM – Optical shelf (M6)

Slot 8 —TNCSlot 7 —BLANKSlot 6 —BLANKSlot 5 and 4 —80-WXC-CSlot 3 —PreSlot 2 —BoosterSlot 1 —TNC

One side per shelf.

80 channel n degree R-OADM

80 channel 8-degree ROADM (Maximum 50 shelves)

Slot 8 —TNCSlot 7 —BLANKSlot 6 —BLANKSlot 5 and 4 —80-WXC-CSlot 3 —PreSlot 2 —BoosterSlot 1 —TNC

Optical shelves—M6 only.

Client shelves—M6 and M12.

80 or 40 channel if two sides can fit in the same shelf

Interconnecting 80- channel and 40- channel networks

40-WXC-C and 80-WXC-C Interconnecting Degrees (M6 shelf only)

80 channel 8-degree ROADM (Maximum 50 shelves)

Shelf M6

Slot 8 —TNC or TSCSlot 7 —BoosterSlot 6 and 5 —40-WXC-CSlot 4 and 3 —40-WXC-CSlot 2 —BoosterSlot 1 —TNC or TSC

Two sides are managed in the same shelf.

Shelf M6

Slot 8 —TNC or TSCSlot 7 —BoosterSlot 6 and 5 —80-WXC-CSlot 4 and 3 —80-WXC-CSlot 2 —BoosterSlot 1 —TNC or TSC

Slot 5,6, and 7—Optional two degree in the same shelf.