Alarm Categories
Cisco Optical Network Controller classifies alarms under these categories:
-
SYSTEM
-
EQUIPMENT
-
MAINTENANCE
-
CONC_SYSTEM
-
TRANSPORT
-
PROTECTION
-
TIMING
-
SECURITY
-
OPTICAL
You may see the following alarm categories:
-
UNKNOWN: When Cisco Optical Network Controller receives an alarm from Cisco Optical Site Manager that is not in the following list.
-
NA: This category is displayed when Cisco Optical Network Controller has an internal issue and cannot get the category info.
| Condition Name | Description | Condition Type | Alarm Category |
|---|---|---|---|
|
ACT-SOFT-VERIF-FAIL |
Active Volume Software Signature Verification Failed |
Alarm |
EQUIPMENT |
|
ADD-OPWR-HDEG |
Port Add Power Degrade High |
Alarm |
OPTICAL |
|
ADD-OPWR-HFAIL |
Port Add Power Fail High |
Alarm |
OPTICAL |
|
ADD-OPWR-LDEG |
Port Add Power Degrade Low |
Alarm |
OPTICAL |
|
ADD-OPWR-LFAIL |
Port Add Power Fail Low |
Alarm |
OPTICAL |
|
ADMIN-CONFIG-INCONSISTENCY |
Admin Configuration is in inconsistent state |
Alarm |
SECURITY |
|
ADMIN-DISABLE |
Disable Inactive User |
Event |
SECURITY |
|
ADMIN-DISABLE-CLR |
Disable Inactive Clear |
Event |
SECURITY |
|
ADMIN-LOCKOUT |
Admin Lockout of User |
Event |
SECURITY |
|
ADMIN-LOCKOUT-CLR |
Admin Lockout Clear |
Event |
SECURITY |
|
ADMIN-LOGOUT |
Admin Logout of User |
Event |
SECURITY |
|
ADMIN-SUSPEND |
Suspend User |
Event |
SECURITY |
|
ADMIN-SUSPEND-CLR |
Suspend User Clear |
Event |
SECURITY |
|
AIS |
Alarm Indication Signal |
Alarm |
TRANSPORT |
|
AIS-L |
Alarm Indication Signal Line |
Alarm |
TRANSPORT |
|
ALC-IN-PROGRESS |
Automatic-link-calibration procedure is running |
Alarm |
OPTICAL |
|
ALC-PROC-FAILED |
Automatic-link-calibration procedure failed |
Alarm |
OPTICAL |
|
ALS |
Automatic Laser Shutdown |
Alarm |
OPTICAL |
|
ALS-DISABLED |
Auto Laser Shutdown Disabled |
Alarm |
OPTICAL |
|
AMPLI-INIT |
Optical Amplifier Initialization |
Alarm |
OPTICAL |
|
AMPLI-OSRI |
Amplifier Optical Safety Remote Interlock |
Alarm |
OPTICAL |
|
APC-BLOCKED |
APC blocked |
Alarm |
OPTICAL |
|
APC-BLOCKED-RX |
APC blocked in RX direction |
Alarm |
OPTICAL |
|
APC-BLOCKED-TX |
APC blocked in TX direction |
Alarm |
OPTICAL |
|
APC-CORR-SKIPPED |
Automatic Power Control Correction Skipped |
Alarm |
OPTICAL |
|
APC-DISABLED |
Automatic Power Control Disabled |
Alarm |
OPTICAL |
|
APC-DISABLED |
Automatic Power Control Disabled |
Alarm |
OPTICAL |
|
APC-END |
Manual Requested Automatic Power Control run Completed |
Alarm |
OPTICAL |
|
APC-HW-FAIL |
APC Hardware Failure |
Alarm |
OPTICAL |
|
APC-OUT-OF-RANGE |
APC Cannot Set Value Due To Range Limits |
Alarm |
OPTICAL |
|
APC-TARGET-PSD-NOT-MET-RX |
APC Target PSD not met in RX direction |
Alarm |
OPTICAL |
|
APC-TARGET-PSD-NOT-MET-TX |
APC Target PSD not met in TX direction |
Alarm |
OPTICAL |
|
APC-WRONG-GAIN |
APC Wrong Gain Set Point |
Alarm |
OPTICAL |
|
APS-NO-RESPONSE |
APS Signal Mismatch |
Alarm |
PROTECTION |
|
APS-PROV-MISM |
APS Protection Type Mismatch |
Alarm |
TRANSPORT |
|
AS-CMD |
Alarms Suppressed By User Command |
Alarm |
MAINTENANCE |
|
AS-MT |
Alarms Suppressed For Maintenance |
Alarm |
MAINTENANCE |
|
ASE-LOADING-DISABLED |
ASE Loading is disabled |
Alarm |
OPTICAL |
|
AUD-ARCHIVE-FAIL |
Archival of Audit Log Failed |
Event |
SYSTEM |
|
AUD-LOG-LOSS |
Audit Log 100 Percent Full - Oldest records will be lost |
Alarm |
SYSTEM |
|
AUD-LOG-LOW |
Audit Log 80 Percent Full |
Alarm |
SYSTEM |
|
AUTH-EC |
Payload Authetication Error Count |
Alarm |
TRANSPORT |
|
AUTO-AMPLI-DISABLED |
Auto Ampli Control Disabled |
Alarm |
OPTICAL |
|
AUTO-AMPLI-MISMATCH |
Auto Ampli Control Mismatch |
Alarm |
OPTICAL |
|
AUTO-AMPLI-RUNNINNG |
Auto Ampli Control Running |
Alarm |
OPTICAL |
|
AUTORESET |
Automatic System Reset |
Alarm |
EQUIPMENT |
|
AUTOWDMANS |
Automatic WDM ANS Finished |
Event |
OPTICAL |
|
AVST-FAILURE |
AVST Failure |
Alarm |
EQUIPMENT |
|
AWG-DEG |
AWG Temperature Degrade |
Alarm |
EQUIPMENT |
|
AWG-FAIL |
AWG Temperature Failure |
Alarm |
EQUIPMENT |
|
AWG-OVERTEMP |
AWG Over-Temperature |
Alarm |
EQUIPMENT |
|
AWG-WARM-UP |
AWG Warm Up |
Alarm |
EQUIPMENT |
|
B-AUTH-EC |
Backward Auth Error Count |
Alarm |
TRANSPORT |
|
BAD-DB-DETECTED |
Bad Database Detected And Database Load Failed |
Alarm |
SYSTEM |
|
BAND-PARTNER-NODE-UNPAIRED |
Node is unpaired from band partner node |
Alarm |
SYSTEM |
|
BAT-FAIL |
Battery Failure |
Alarm |
EQUIPMENT |
|
BDI |
Backward Defect Indication |
Alarm |
TRANSPORT |
|
BERT-ENBL |
BERT Enabled |
Alarm |
TRANSPORT |
|
BERT-SYNC-FAIL |
BERT Synchronization Status Failed |
Alarm |
TIMING |
|
BIOS-IMAGE-CORRUPTION |
BIOS image corruption |
Alarm |
EQUIPMENT |
|
BKUPMEMP |
Primary Non-Volatile Backup Memory Failure |
Alarm |
EQUIPMENT |
|
BP-FPGA-IMAGE-CORRUPTION |
BP FPGA Image Corruption |
Alarm |
EQUIPMENT |
|
BP-FPGA-PCIE-ERROR |
BP FPGA PCIE Error |
Alarm |
EQUIPMENT |
|
BP-FPGA-XR-EP-FPGA-PCIE-ERROR |
BP FPGA XR EP FPGA PCIe Error |
Alarm |
EQUIPMENT |
|
BP-LPBKFACILITY |
Back-panel Facility Loopback |
Alarm |
MAINTENANCE |
|
BP-LPBKTERMINAL |
Back-panel Terminal Loopback |
Alarm |
MAINTENANCE |
|
CANNOT-BE-EQUALIZED |
Incoming signal cannot be equalized |
Alarm |
OPTICAL |
|
CARD-IS-SHUTDOWN |
Card failed to come up after multiple recovery attempts |
Alarm |
EQUIPMENT |
|
CARD-UNREACHABLE |
RemoteCard Not Reachable For Key Exchange. Retrying ... |
Alarm |
EQUIPMENT |
|
CARLOSS |
Carrier Loss On The LAN |
Alarm |
OPTICAL |
|
CASETEMP-DEG |
Case Temperature Degrade |
Alarm |
EQUIPMENT |
|
CD |
Chromatic Dispersion |
Alarm |
OPTICAL |
|
CHAN-PWR-THRESHOLD-CHECK |
Channel Power would fall below threshold value |
Alarm |
OPTICAL |
|
CHANNEL-NOISE-LOADED |
Channel is Loaded with Noise |
Alarm |
OPTICAL |
|
CHANNEL-READY |
Channel Presence is Detected and Ready |
Alarm |
OPTICAL |
|
CLDRESTART |
Cold Restart |
Alarm |
EQUIPMENT |
|
COMM-FAIL |
Plug-in Module Communication Failure |
Alarm |
EQUIPMENT |
|
COMMIT-REPLACE-FAILED |
Configuration commit replace failed |
Alarm |
SYSTEM |
|
COMP-CARD-MISSING |
Companion Card Missing |
Alarm |
EQUIPMENT |
|
CONFIG-INCONSISTENCY |
Configuration is in inconsistent state |
Alarm |
SYSTEM |
|
CONTBUS-A-18 |
Controller Card A To DCC A Processor Communication Failure |
Alarm |
EQUIPMENT |
|
CONTBUS-B-18 |
Controller Card B To DCC B Processor Communication Failure |
Alarm |
EQUIPMENT |
|
CONTBUS-CLK-A |
Clock Bus Failure - Shelf Controller A |
Alarm |
EQUIPMENT |
|
CONTBUS-CLK-B |
Clock Bus Failure - Shelf Controller B |
Alarm |
EQUIPMENT |
|
CONTBUS-DISABLED |
Slot Commmunication Disabled |
Alarm |
EQUIPMENT |
|
CONTBUS-IO-A |
Peer To Peer Slot Communication Failure |
Alarm |
EQUIPMENT |
|
CONTBUS-IO-B |
Peer To Peer Slot Communication Failure |
Alarm |
EQUIPMENT |
|
COOL-MISM |
Cooling Profile Mismatch |
Alarm |
EQUIPMENT |
|
CP-UNVER-CLEARED |
Control Plane Unverified Cleared Alarms Present |
Alarm |
SYSTEM |
|
CPP-INCAPABLE |
Card/Ports Unable To Provide Protection |
Alarm |
EQUIPMENT |
|
CPU-FPGA-PCIE-ERROR |
CPU FPGA PCIe Error |
Alarm |
EQUIPMENT |
|
CRYPTO-HW-FAILURE |
Cryptographic self-test failuret |
Alarm |
SECURITY |
|
CRYPTO-INDEX-MISMATCH |
Crypto Index Mismatch |
Alarm |
SECURITY |
|
CRYPTO-KEY-EXPIRED |
Crypto key expired |
Alarm |
SECURITY |
|
DATAFLT |
Software Fault - Data Integrity Fault |
Alarm |
SYSTEM |
|
DBBACKUP-FAIL |
Database Backup Failed |
Event |
SYSTEM |
|
DBBACKUP-IN-PROGRESS |
Database Backup In Progress |
Alarm |
SYSTEM |
|
DBOSYNC |
Standby Database Out of Sync |
Alarm |
SYSTEM |
|
DBREST-IN-PROGRESS |
Database Restore In Progress |
Alarm |
SYSTEM |
|
DBRESTORE-FAIL |
Database Restore Failed |
Event |
SYSTEM |
|
DCU-LOSS-FAIL |
DCU Loss Failure |
Alarm |
OPTICAL |
|
DEG-SER |
FEC Degraded Symbol Error Rate |
Event |
TRANSPORT |
|
DEGREE-MISMATCH |
Degree Mismatch |
Alarm |
SYSTEM |
|
DGD |
Differential Group Delay |
Alarm |
OPTICAL |
|
DISK-SPACE-FULL |
No Space Left On Device |
Alarm |
SYSTEM |
|
DISK-SPACE-LOW |
Low Disk Space Remaining On Device |
Alarm |
SYSTEM |
|
DR-UNAVAILABLE |
Disaster recovery boot is currently unavailable due to a missing or corrupted chassis SSD. If an install transaction is in progress, this cannot be cleared until the transaction is completed |
Alarm |
SYSTEM |
|
DSP-COMM-FAIL |
DSP Communication Failure |
Alarm |
EQUIPMENT |
|
DSP-FAIL |
DSP Failure |
Alarm |
EQUIPMENT |
|
DUP-IPADDR |
IP Address A1ready In Use Within The Same DCC Area |
Alarm |
SYSTEM |
|
DUP-NODENAME |
Node name already in use within the same DCC Area |
Alarm |
SYSTEM |
|
DUP-SHELF-ID |
Duplicated Shelf Identifier |
Alarm |
SYSTEM |
|
EHIBATVG |
Extreme High Volt |
Alarm |
EQUIPMENT |
|
ELWBATVG |
Extreme Low Volt |
Alarm |
EQUIPMENT |
|
EMB-AMPLIFIER-SATURATED |
Embedded amplifier saturated alarm |
Alarm |
OPTICAL |
|
ENC-CERT-EXP |
MIC cert is expired switch to LSC |
Alarm |
TRANSPORT |
|
EOC |
SDCC Termination Failure |
Alarm |
TRANSPORT |
|
EOC-E |
Ethernet OSC Termination Failure |
Alarm |
TRANSPORT |
|
EOC-L |
Line DCC Termination Failure |
Alarm |
TRANSPORT |
|
EPROM-SUDI-SN-MISMATCH |
Card Serial Number and Certificate Serial Number Mismatch |
Alarm |
EQUIPMENT |
|
EQPT |
Equipment Failure |
Alarm |
EQUIPMENT |
|
EQPT-DEGRADE |
Equipment Degrade |
Alarm |
EQUIPMENT |
|
EQPT-DIAG |
Diagnostic Failure |
Alarm |
EQUIPMENT |
|
EQPT-FAIL |
Board Failure |
Alarm |
EQUIPMENT |
|
EQPT-FPGA-IMAGE-AVAILABLE |
Different FPGA Image Available |
Alarm |
EQUIPMENT |
|
EQPT-MISS |
Replaceable Equipment/Unit is Missing |
Alarm |
EQUIPMENT |
|
ETH-LINKLOSS |
Rear Panel Ethernet Link Removed |
Alarm |
EQUIPMENT |
|
EVAL-LIC |
Evaluation License Is In Use |
Alarm |
SYSTEM |
|
EXPECTED-POWER-FAIL |
Channel Power Reading Exceeds the Expected Power Tolerance Limits |
Alarm |
OPTICAL |
|
EXT |
Failure Detected External To The NE |
Alarm |
SYSTEM |
|
FAILTOSW |
Failure To Switch To Protection |
Alarm |
PROTECTION |
|
FAN |
Fan Failure |
Alarm |
EQUIPMENT |
|
FAN-OUT-OF-TOLERANCE |
Fan Out of tolerance |
Alarm |
EQUIPMENT |
|
FAN-POWER-ERROR |
FAN tray Power Error |
Alarm |
EQUIPMENT |
|
FAN-SENSOR-FAILED |
Sensor in failed state |
Alarm |
EQUIPMENT |
|
FANDEGRADE |
Partial Fan Failure |
Alarm |
EQUIPMENT |
|
FC-DE-NES |
Fibre Channel Distance Extension Function Not Established |
Alarm |
TRANSPORT |
|
FC-NO-CREDITS |
Fibre Channel Distance Extension Credit Starvation |
Alarm |
TRANSPORT |
|
FDI |
Forward Defect Indication |
Alarm |
OPTICAL |
|
FEC-MISM |
FEC Mismatched |
Alarm |
TRANSPORT |
|
FEED-MISMATCH |
Feed Not Available/Improper Connection |
Alarm |
EQUIPMENT |
|
FIBERTEMP-DEG |
Fiber Temperature Degrade |
Alarm |
EQUIPMENT |
|
FIRMWARE-DOWNLOAD |
Firmware Download In Progress |
Event |
EQUIPMENT |
|
FIRMWARE-UPG |
Firmware Upgrade In Progress |
Alarm |
EQUIPMENT |
|
FIRMWARE-UPG-COMPLETE |
Firmware Upgrade Completed |
Event |
EQUIPMENT |
|
FIRMWARE-UPG-FAIL |
Firmware Upgrade Failed |
Alarm |
EQUIPMENT |
|
FLASH0-ERROR |
CPU Flash 0 Error |
Alarm |
EQUIPMENT |
|
FLASH1-ERROR |
CPU Flash 1 Error |
Alarm |
EQUIPMENT |
|
FLEXO-GIDM |
FlexO Group Identification Mismatch |
Alarm |
TRANSPORT |
|
FLEXO-LOF |
FlexO Loss of Frame |
Alarm |
TRANSPORT |
|
FLEXO-LOM |
FlexO Loss of MultiFrame |
Alarm |
TRANSPORT |
|
FLEXO-MM |
FlexO Map Mismatch |
Alarm |
TRANSPORT |
|
FLEXO-RDI |
FlexO Remote Defect Indicator |
Alarm |
TRANSPORT |
|
FOIC-GIDM |
FOIC Group ID mismatch defect |
Alarm |
TRANSPORT |
|
FOIC-LDI-LD |
FOIC Link Degrade indicator - Local Degrade |
Alarm |
TRANSPORT |
|
FOIC-LDI-RD |
FOIC Link Degrade indicator- Remote Degrade |
Alarm |
TRANSPORT |
|
FOIC-LOF-LOM |
FOIC Loss of Frame loss of Multiframe |
Alarm |
TRANSPORT |
|
FOIC-LOL |
FOIC Loss of Lock Detect |
Alarm |
TRANSPORT |
|
FOIC-LOM |
FOIC Loss of Multiframe Indication |
Alarm |
TRANSPORT |
|
FOIC-PMM |
FOIC Phy Map mismatch Alarm |
Alarm |
TRANSPORT |
|
FOIC-RPF |
FOIC Remote Phy Fault Detect |
Alarm |
TRANSPORT |
|
FOIC-TIM |
FOIC Trail Trace Identifier Mismatch |
Alarm |
TRANSPORT |
|
FORCED-REQ |
Forced Switch Request |
Alarm |
PROTECTION |
|
FPD-UPG-REQUIRED |
Firmware upgrade required |
Alarm |
EQUIPMENT |
|
FPGA-ERROR |
BP FPGA Error |
Alarm |
EQUIPMENT |
|
FPGA-SEU-UNCORR |
BP FPGA SEU Uncorrected Error |
Alarm |
EQUIPMENT |
|
FPGA-UPGRADE-FAILED |
FPGA Upgrade fail |
Alarm |
EQUIPMENT |
|
FRCDSWTOINT |
Forced Switch To Internal Clock |
Alarm |
TIMING |
|
FRCDSWTOPRI |
Forced Switch To Primary Reference |
Alarm |
TIMING |
|
FRCDSWTOSEC |
Forced Switch To Second Reference |
Alarm |
TIMING |
|
FRCDSWTOTHIRD |
Forced Switch To Third Reference |
Alarm |
TIMING |
|
FRNGSYNC |
Free Running Synchronization Mode |
Alarm |
TIMING |
|
FTA-MISMATCH |
FanTray Mismatch |
Alarm |
EQUIPMENT |
|
GAIN-HDEG |
Optical Amplifier Gain Degrade High |
Alarm |
OPTICAL |
|
GAIN-HFAIL |
Optical Amplifier Gain Failure High |
Alarm |
OPTICAL |
|
GAIN-LDEG |
Optical Amplifier Gain Degrade Low |
Alarm |
OPTICAL |
|
GAIN-LFAIL |
Optical Amplifier Gain Failure Low |
Alarm |
OPTICAL |
|
GAIN-NEAR-LIMIT |
Amplifier Gain is near its limit |
Alarm |
OPTICAL |
|
GCC-EOC |
GCC Termination Failure |
Alarm |
TRANSPORT |
|
GE-OOSYNC |
GigaBit Ethernet Out of Sync |
Alarm |
TRANSPORT |
|
GFP-CSF |
GFP Client Signal Fail Detected |
Alarm |
TRANSPORT |
|
GFP-CSF-SIGLOSS |
GFP Client Signal Fail Detected Due To Sigloss |
Alarm |
TRANSPORT |
|
GFP-CSF-SYNCLOSS |
GFP Client Signal Fail Detected Due To Syncloss |
Alarm |
TRANSPORT |
|
GFP-DE-MISMATCH |
GFP Fibre Channel Distance Extension Mismatch |
Alarm |
TRANSPORT |
|
GFP-EX-MISMATCH |
GFP Extension Header Mismatch |
Alarm |
TRANSPORT |
|
GFP-LFD |
GFP Loss of Frame Delineation |
Alarm |
TRANSPORT |
|
GFP-NO-BUFFERS |
GFP Fibre Channel Distance Extension Buffer Starvation |
Alarm |
TRANSPORT |
|
GFP-UP-MISMATCH |
GFP User Payload Mismatch |
Alarm |
TRANSPORT |
|
HELLO |
OSPF Hello Fail |
Alarm |
SYSTEM |
|
HI-BER |
High Bit Error Rate |
Alarm |
TRANSPORT |
|
HI-CCVOLT |
Composite Clock High Line Voltage |
Alarm |
TIMING |
|
HI-LASERBIAS |
Equipment High Laser Bias |
Alarm |
EQUIPMENT |
|
HI-LASERTEMP |
Equipment High Laser Temp |
Alarm |
EQUIPMENT |
|
HI-RX-BR-PWR |
Input High BR Power |
Alarm |
OPTICAL |
|
HI-RXPOWER |
Facility High Rx power |
Alarm |
OPTICAL |
|
HI-SER |
High Symbol Error Rate |
Event |
TRANSPORT |
|
HI-TX-BR-PWR |
Otput High BR Power |
Alarm |
OPTICAL |
|
HI-TXPOWER |
Equipment High Tx power |
Alarm |
EQUIPMENT |
|
HIBATVG |
High Volt |
Alarm |
EQUIPMENT |
|
HIGH-VOLTAGE |
high voltage alarm |
Alarm |
EQUIPMENT |
|
HITEMP |
High Temperature |
Alarm |
EQUIPMENT |
|
HITEMP |
High Temperature |
Alarm |
EQUIPMENT |
|
HLDOVRSYNC |
Holdover Synchronization Mode |
Alarm |
TIMING |
|
I-HITEMP |
Industrial High Temperature |
Alarm |
EQUIPMENT |
|
IDLE |
Idle Signal Condition |
Alarm |
TRANSPORT |
|
IMPROPRMVL |
Improper Removal |
Alarm |
EQUIPMENT |
|
IMPROPRMVL-FS |
Improper removal of Fiber Shuffle |
Alarm |
EQUIPMENT |
|
INSTALL-IN-PROGRESS |
SW Installation In Progress |
Alarm |
SYSTEM |
|
INTRUSION |
Security: Invalid Login Username - See Audit Trail |
Event |
SECURITY |
|
INTRUSION-PSWD |
Security Intrusion Attempt Detected - See Audit Log |
Alarm |
SECURITY |
|
INTRUSION-USERID |
Security Intrusion Attempt Detected - See Audit Log |
Event |
SECURITY |
|
INVALID-CARD-SLOT |
Invalid Card Slot |
Alarm |
EQUIPMENT |
|
INVALID-SENSOR-READ-ERR |
Invalid sensor read error |
Alarm |
EQUIPMENT |
|
INVALID-SYSDB |
Invalid System DB |
Alarm |
SYSTEM |
|
INVMACADR |
Invalid MAC Address |
Alarm |
SYSTEM |
|
IPC-LASER-FAIL |
Ipc Laser failure |
Alarm |
MAINTENANCE |
|
IPC-LOOPBACK-MISS |
Patchcords Verification Loopback Missing |
Alarm |
MAINTENANCE |
|
IPC-VERIFICATION-DEGRADE |
Patchcords Verification Degrade |
Alarm |
MAINTENANCE |
|
IPC-VERIFICATION-EXCESSIVE-LOSS |
Measured Patchcord Loss above the Threshold |
Alarm |
MAINTENANCE |
|
IPC-VERIFICATION-FAIL |
Patchcords Verification Failure |
Alarm |
MAINTENANCE |
|
IPC-VERIFICATION-RUNNING |
Patchcords Verification Running |
Alarm |
MAINTENANCE |
|
KEY-EX-FAIL |
Primary Key Exchange Failed |
Alarm |
TRANSPORT |
|
KEY-WRITE-FAIL |
Key Program On FPGA Failed |
Alarm |
TRANSPORT |
|
LAN-POL-REV |
Lan Connection Polarity Reversed |
Alarm |
EQUIPMENT |
|
LASER-APR |
Laser Auto Power Reduction |
Alarm |
OPTICAL |
|
LASERBIAS-DEG |
Laser Bias Degrade |
Alarm |
EQUIPMENT |
|
LASERBIAS-FAIL |
Laser Bias Failure |
Alarm |
EQUIPMENT |
|
LASEREOL |
Laser Approaching End of Life |
Alarm |
EQUIPMENT |
|
LASERTEMP-DEG |
Laser Temperature Degrade |
Alarm |
EQUIPMENT |
|
LC-BOOT-TIMEOUT |
LC Boot Timeout |
Alarm |
EQUIPMENT |
|
LC-CPU-IMAGE-CORRUPTION |
LC CPU Image Corruption |
Alarm |
EQUIPMENT |
|
LC-DP-IMAGE-CORRUPTION |
LC Data Plane Image Corruption |
Alarm |
EQUIPMENT |
|
LC-FPD-DEV-FAILURE |
CPU_MOD_FW is corrupt, system booted with golden copy |
Alarm |
EQUIPMENT |
|
LC-OFFLINE-ERROR |
LC Offline Error |
Alarm |
EQUIPMENT |
|
LCMODE-CONFIG-CHANGED |
LCMODE changed, delete the datapath config and reload line card |
Alarm |
SYSTEM |
|
LCMODE-CONFIG-INVALID |
LC Mode Configuration Invalid |
Alarm |
SYSTEM |
|
LCMODE-NOT-CONFIG |
LC Mode Configuration Not Applied |
Alarm |
SYSTEM |
|
LIC-COMM-FAIL |
Communications Failure With Cisco Licensing Cloud |
Alarm |
SYSTEM |
|
LIC-EXPIRED |
License Expired |
Alarm |
SYSTEM |
|
LIC-EXPIRING-SHORTLY |
License Will Expire Within 24 Hours |
Alarm |
SYSTEM |
|
LIC-EXPIRING-SOON |
License Will Expire At Any Time After 1 Day But Before 14 Days |
Alarm |
SYSTEM |
|
LIC-MISSING |
License Is Missing |
Alarm |
SYSTEM |
|
LIC-OUT-OF-COMPL |
One Or More Entitlements Are Out Of Compliance |
Alarm |
SYSTEM |
|
LIC-SIA-OF-COMPL-UPGRADE-BLOCKED |
SW Upgrade will be blocked as SIA Grace Period has expired |
Alarm |
SYSTEM |
|
LIC-SIA-OUT-OF-COMPL-GP-REM |
SW Upgrade is still allowed as SIA Grace Period is remaining |
Alarm |
SYSTEM |
|
LIC-UPGRADE-OF-COMPL-UPGRADE-BLOCKED |
SW Upgrade will be blocked as Upgrade License Grace Period has expired |
Alarm |
SYSTEM |
|
LIC-UPGRADE-OUT-OF-COMPL-GP-REM |
SW Upgrade is still allowed as Upgrade License Grace Period is remaining |
Alarm |
SYSTEM |
|
LINK-BROKEN |
Ha link Broken |
Alarm |
SYSTEM |
|
LO-LASERBIAS |
Equipment Low Laser Bias |
Alarm |
EQUIPMENT |
|
LO-LASERTEMP |
Equipment Low Laser Temp |
Alarm |
EQUIPMENT |
|
LO-RXPOWER |
Facility Low Rx power |
Alarm |
OPTICAL |
|
LO-TXPOWER |
Equipment Low Tx power |
Alarm |
EQUIPMENT |
|
LOA |
Loss of Alignment |
Alarm |
TRANSPORT |
|
LOCAL-CERT-CHAIN-VERIFICATION-FAILED |
Local cert chain verification failed |
Alarm |
SECURITY |
|
LOCAL-CERT-EXPIRED |
Local certificate expired |
Alarm |
SECURITY |
|
LOCAL-CERT-EXPIRING-WITHIN-30-DAYS |
Local cert expiring within 30 days |
Alarm |
SECURITY |
|
LOCAL-CERT-ISSUED-FOR-FUTURE-DATE |
Local cert issued for future date |
Alarm |
SECURITY |
|
LOCAL-DEG-SER |
Local FEC Degraded Symbol Error Rate |
Event |
TRANSPORT |
|
LOCAL-FAULT |
Local Fault |
Alarm |
TRANSPORT |
|
LOCAL-SUDI-CERT-VERIFICATION-FAILED |
Local sudi cert verification failed |
Alarm |
SECURITY |
|
LOCKOUT-REQ |
Lockout Switch Request |
Alarm |
PROTECTION |
|
LOF |
Loss Of Frame |
Alarm |
TRANSPORT |
|
LOF |
Loss Of Frame |
Alarm |
TRANSPORT |
|
LOGIN-FAIL-LOCKOUT |
Security: Invalid Login - Locked Out - See Audit Log |
Event |
SECURITY |
|
LOGIN-FAIL-ONALRDY |
Security: Invalid Login - Already Logged On - See Audit Log |
Event |
SECURITY |
|
LOGIN-FAILURE-PSWD |
Security: Invalid Login - Password - See Audit Log |
Event |
SECURITY |
|
LOGIN-FAILURE-USER |
Security: Invalid Login - Username - See Audit Log |
Event |
SECURITY |
|
LOGIN-MISSING-GROUP |
Missing Authorization Group Information |
Event |
SYSTEM |
|
LOGOUT-IDLE-USER |
Automatic Logout of IdleUser |
Event |
SECURITY |
|
LOM |
Loss of Multi-Frame |
Alarm |
TRANSPORT |
|
LOS |
Loss Of Signal |
Alarm |
OPTICAL |
|
LOS |
Loss Of Signal |
Alarm |
OPTICAL |
|
LOS-D |
Loss Of DFB Signal |
Alarm |
OPTICAL |
|
LOS-O |
Incoming Overhead Signal Absent |
Alarm |
OPTICAL |
|
LOS-P |
Incoming Payload Signal Absent |
Alarm |
OPTICAL |
|
LOS-RAMAN |
Loss Of Raman Signal |
Alarm |
OPTICAL |
|
LOW-VOLTAGE |
low voltage alarm |
Alarm |
EQUIPMENT |
|
LPBKFACILITY |
Facility Loopback |
Alarm |
MAINTENANCE |
|
LPBKTERMINAL |
Terminal Loopback |
Alarm |
MAINTENANCE |
|
LSC-NOT-PRESENT-MIC-IN-USE |
LSC not present using MIC |
Alarm |
EQUIPMENT |
|
LWBATVG |
Low Volt |
Alarm |
EQUIPMENT |
|
MAN-LASER-RESTART |
Manual Laser Restart |
Alarm |
OPTICAL |
|
MAN-REQ |
Manual Switch Request |
Alarm |
PROTECTION |
|
MANRESET |
Manual System Reset |
Alarm |
MAINTENANCE |
|
MANSWTOINT |
Manual Switch To Internal Clock |
Alarm |
TIMING |
|
MANSWTOPRI |
Manual Switch To Primary Reference |
Alarm |
TIMING |
|
MANSWTOSEC |
Manual Switch To Second Reference |
Alarm |
TIMING |
|
MANSWTOTHIRD |
Manual Switch To Third Reference |
Alarm |
TIMING |
|
MASTERKEY-SUCCESS |
MasterKey Exchange Success |
Event |
SECURITY |
|
MAX-AUTH-LIST |
Reached Max Authentication List |
Alarm |
TRANSPORT |
|
MB-SSD-ATA-ERRORS |
Motherboard SSD ATA Errors |
Alarm |
EQUIPMENT |
|
MEA |
Mismatch Of Equipment And Attributes |
Alarm |
EQUIPMENT |
|
MEA |
Mismatch Of Equipment And Attributes |
Alarm |
EQUIPMENT |
|
MEM-GONE |
Free Memory On Card Near Zero |
Alarm |
EQUIPMENT |
|
MEM-LOW |
Free Memory On Card Very Low |
Alarm |
EQUIPMENT |
|
MFGMEM |
Manufacturing Data Memory (EEPROM) Failure |
Alarm |
EQUIPMENT |
|
MS-AIS |
AIS - Multiplex Section - Alarm Indication Signal |
Alarm |
TRANSPORT |
|
MS-DEG |
Multiplex Section - Signal Degraded |
Alarm |
TRANSPORT |
|
MS-EOC |
Multiplex Section DCC Termination Failure |
Alarm |
TRANSPORT |
|
MS-EXC |
Multiplex Section - Excessive Errors |
Alarm |
TRANSPORT |
|
MS-RDI |
RDI - Multiplex Section - Remote Defect/Alarm Indication |
Alarm |
TRANSPORT |
|
NE-CONFIG-INCONSISTENT |
Device has the Config Blocked due to an Inconsistency |
Event |
SYSTEM |
|
NE-DISCONNECTED |
Connection To Managed NE Lost |
Alarm |
SYSTEM |
|
NE-EVENT-DISCONNECTED |
Event Channel To Managed NE Lost |
Alarm |
SYSTEM |
|
NE-NOT-AUTH-ACCESS |
Not Authorised Access To Managed NE |
Alarm |
SYSTEM |
|
NE-VER-NOT-SUPP |
Not Supported Version Of Managed NE |
Alarm |
SYSTEM |
|
NEIGHBOUR-MISSING |
Neighbour not found |
Alarm |
SYSTEM |
|
NO-SHARED-CIPHERS |
Different Ciphers Used by Client and Server |
Alarm |
TRANSPORT |
|
NO-VALID-USB-DB |
No Valid USB DB exists |
Alarm |
SYSTEM |
|
NODE-FACTORY-MODE |
Node in Factory Mode |
Alarm |
SYSTEM |
|
NODE-INCONSISTENCIES |
Owner and/or partner packages on at least one node do not match the active RP |
Alarm |
SYSTEM |
|
NODE-OBFL-ERROR |
Node OBFL Error |
Alarm |
EQUIPMENT |
|
NON-CISCO-PPM |
Non Cisco PPM Inserted |
Alarm |
EQUIPMENT |
|
NON-TRAF-AFFECT-SEC-UPG-REQUIRED |
Non Traffic Affecting Security Upgrade Required |
Alarm |
SECURITY |
|
NOS |
Not-Operational primitive Sequence |
Alarm |
TRANSPORT |
|
OCHNC-INC |
Optical Channel Incomplete |
Alarm |
TRANSPORT |
|
OCHNC-MT |
OCHNC Maintenance |
Alarm |
MAINTENANCE |
|
OCHTERM-INC |
Optical Termination Incomplete |
Alarm |
TRANSPORT |
|
ODUK-1-AIS-PM |
ODUk1 Alarm Indication Signal |
Alarm |
TRANSPORT |
|
ODUK-2-AIS-PM |
ODUk2 Alarm Indication Signal |
Alarm |
TRANSPORT |
|
ODUK-3-AIS-PM |
ODUk3 Alarm Indication Signal |
Alarm |
TRANSPORT |
|
ODUK-4-AIS-PM |
ODUk4 Alarm Indication Signal |
Alarm |
TRANSPORT |
|
ODUK-AIS-PM |
ODUk: PM Alarm Indication Signal |
Alarm |
TRANSPORT |
|
ODUK-AIS-TCM1 |
TCM1 Alarm Indication Signal |
Event |
TRANSPORT |
|
ODUK-AIS-TCM2 |
TCM2 Alarm Indication Signal |
Event |
TRANSPORT |
|
ODUK-AIS-TCM3 |
TCM3 Alarm Indication Signal |
Event |
TRANSPORT |
|
ODUK-AIS-TCM4 |
TCM4 Alarm Indication Signal |
Event |
TRANSPORT |
|
ODUK-AIS-TCM5 |
TCM5 Alarm Indication Signal |
Event |
TRANSPORT |
|
ODUK-AIS-TCM6 |
TCM6 Alarm Indication Signal |
Event |
TRANSPORT |
|
ODUK-BDI-PM |
ODUk: PM Backward Defect Indication |
Alarm |
TRANSPORT |
|
ODUK-BDI-TCM1 |
TCM1 Backward Defect Monitoring |
Event |
TRANSPORT |
|
ODUK-BDI-TCM2 |
TCM2 Backward Defect Monitoring |
Event |
TRANSPORT |
|
ODUK-BDI-TCM3 |
TCM3 Backward Defect Monitoring |
Event |
TRANSPORT |
|
ODUK-BDI-TCM4 |
TCM4 Backward Defect Monitoring |
Event |
TRANSPORT |
|
ODUK-BDI-TCM5 |
TCM5 Backward Defect Monitoring |
Event |
TRANSPORT |
|
ODUK-BDI-TCM6 |
TCM6 Backward Defect Monitoring |
Event |
TRANSPORT |
|
ODUK-BIAE |
Path Monitoring Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-BIAE-TCM1 |
TCM1 Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-BIAE-TCM2 |
TCM2 Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-BIAE-TCM3 |
TCM3 Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-BIAE-TCM4 |
TCM4 Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-BIAE-TCM5 |
TCM5 Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-BIAE-TCM6 |
TCM6 Backward Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE |
Path Monitoring Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE-TCM1 |
TCM1 Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE-TCM2 |
TCM2 Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE-TCM3 |
TCM3 Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE-TCM4 |
TCM4 Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE-TCM5 |
TCM5 Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-IAE-TCM6 |
TCM6 Incoming Alignment Error |
Event |
TRANSPORT |
|
ODUK-LCK-PM |
ODUk: Locked Defect - PM |
Alarm |
TRANSPORT |
|
ODUK-LCK-TCM1 |
TCM1 Locked |
Event |
TRANSPORT |
|
ODUK-LCK-TCM2 |
TCM2 Locked |
Event |
TRANSPORT |
|
ODUK-LCK-TCM3 |
TCM3 Locked |
Event |
TRANSPORT |
|
ODUK-LCK-TCM4 |
TCM4 Locked |
Event |
TRANSPORT |
|
ODUK-LCK-TCM5 |
TCM5 Locked |
Event |
TRANSPORT |
|
ODUK-LCK-TCM6 |
TCM6 Locked |
Event |
TRANSPORT |
|
ODUK-LTC-TCM1 |
TCM1 Loss of Tandem Connection |
Event |
TRANSPORT |
|
ODUK-LTC-TCM2 |
TCM2 Loss of Tandem Connection |
Event |
TRANSPORT |
|
ODUK-LTC-TCM3 |
TCM3 Loss of Tandem Connection |
Event |
TRANSPORT |
|
ODUK-LTC-TCM4 |
TCM4 Loss of Tandem Connection |
Event |
TRANSPORT |
|
ODUK-LTC-TCM5 |
TCM5 Loss of Tandem Connection |
Event |
TRANSPORT |
|
ODUK-LTC-TCM6 |
TCM6 Loss of Tandem Connection |
Event |
TRANSPORT |
|
ODUK-OCI-PM |
ODUk: Open Connection Indication |
Alarm |
TRANSPORT |
|
ODUK-OCI-TCM1 |
TCM1 Open Connection Indication |
Event |
TRANSPORT |
|
ODUK-OCI-TCM2 |
TCM2 Open Connection Indication |
Event |
TRANSPORT |
|
ODUK-OCI-TCM3 |
TCM3 Open Connection Indication |
Event |
TRANSPORT |
|
ODUK-OCI-TCM4 |
TCM4 Open Connection Indication |
Event |
TRANSPORT |
|
ODUK-OCI-TCM5 |
TCM5 Open Connection Indication |
Event |
TRANSPORT |
|
ODUK-OCI-TCM6 |
TCM6 Open Connection Indication |
Event |
TRANSPORT |
|
ODUK-SD-PM |
ODUk: Signal Degrade |
Alarm |
TRANSPORT |
|
ODUK-SD-TCM1 |
TCM1 Signal Degrade |
Event |
TRANSPORT |
|
ODUK-SD-TCM2 |
TCM2 Signal Degrade |
Event |
TRANSPORT |
|
ODUK-SD-TCM3 |
TCM3 Signal Degrade |
Event |
TRANSPORT |
|
ODUK-SD-TCM4 |
TCM4 Signal Degrade |
Event |
TRANSPORT |
|
ODUK-SD-TCM5 |
TCM5 Signal Degrade |
Event |
TRANSPORT |
|
ODUK-SD-TCM6 |
TCM6 Signal Degrade |
Event |
TRANSPORT |
|
ODUK-SF-PM |
ODUk: Signal Failure |
Alarm |
TRANSPORT |
|
ODUK-SF-TCM1 |
TCM1 Signal Failure |
Event |
TRANSPORT |
|
ODUK-SF-TCM2 |
TCM2 Signal Failure |
Event |
TRANSPORT |
|
ODUK-SF-TCM3 |
TCM3 Signal Failure |
Event |
TRANSPORT |
|
ODUK-SF-TCM4 |
TCM4 Signal Failure |
Event |
TRANSPORT |
|
ODUK-SF-TCM5 |
TCM5 Signal Failure |
Event |
TRANSPORT |
|
ODUK-SF-TCM6 |
TCM6 Signal Failure |
Event |
TRANSPORT |
|
ODUK-TIM-PM |
ODUk: Trail Trace Identifier Mismatch |
Alarm |
TRANSPORT |
|
ODUK-TIM-TCM1 |
TCM1 Trail Trace Identifier Mismatch |
Event |
TRANSPORT |
|
ODUK-TIM-TCM2 |
TCM2 Trail Trace Identifier Mismatch |
Event |
TRANSPORT |
|
ODUK-TIM-TCM3 |
TCM3 Trail Trace Identifier Mismatch |
Event |
TRANSPORT |
|
ODUK-TIM-TCM4 |
TCM4 Trail Trace Identifier Mismatch |
Event |
TRANSPORT |
|
ODUK-TIM-TCM5 |
TCM5 Trail Trace Identifier Mismatch |
Event |
TRANSPORT |
|
ODUK-TIM-TCM6 |
TCM6 Trail Trace Identifier Mismatch |
Event |
TRANSPORT |
|
ONE-OR-MORE-FAN-TRAY-ABSENT |
One or more Fan Trays missing |
Alarm |
EQUIPMENT |
|
ONE-OR-MORE-LC-MISSING |
One or more LCs missing, running fans at max speedOne or more LCs missing, running fans at max speed |
Alarm |
EQUIPMENT |
|
OPEN-SLOT |
Open Slot(s) |
Alarm |
EQUIPMENT |
|
OPT-MOD-ABSENT |
One or more Optical Modules missing |
Alarm |
EQUIPMENT |
|
OPU-CSF |
OPU Client Signal Fail |
Alarm |
TRANSPORT |
|
OPWR-HDEG |
Optical Power Degrade High |
Alarm |
OPTICAL |
|
OPWR-HFAIL |
Optical Power Failure High |
Alarm |
OPTICAL |
|
OPWR-LDEG |
Optical Power Degrade Low |
Alarm |
OPTICAL |
|
OPWR-LFAIL |
Optical Power Failure Low |
Alarm |
OPTICAL |
|
OSNR |
Optical Signal-to-Noise Ratio |
Alarm |
TRANSPORT |
|
OSRION |
Optical Safety Remote Interlock On |
Alarm |
OPTICAL |
|
OTDR-ABSOLUTE-A-EXCEEDED-RX |
Attenuation Exceeded Absolute Threshold - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ABSOLUTE-A-EXCEEDED-TX |
Attenuation Exceeded Absolute Threshold - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ABSOLUTE-R-EXCEEDED-RX |
Reflectance Exceeded Absolute Threshold - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ABSOLUTE-R-EXCEEDED-TX |
Reflectance Exceeded Absolute Threshold - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-BASELINE-A-EXCEEDED-RX |
Attenuation Exceeded Baseline Threshold - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-BASELINE-A-EXCEEDED-TX |
Attenuation Exceeded Baseline Threshold - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-BASELINE-R-EXCEEDED-RX |
Reflectance Exceeded Baseline Threshold - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-BASELINE-R-EXCEEDED-TX |
Reflectance Exceeded Baseline Threshold - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-FAST-FAR-END-IN-PROGRESS |
OTDR Fast Scan Is In Progress On Remote Side |
Alarm |
MAINTENANCE |
|
OTDR-FAST-SCAN-IN-PROGRESS-RX |
OTDR Fast Scan Is In Progress - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-FAST-SCAN-IN-PROGRESS-TX |
OTDR Fast Scan Is In Progress - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-FIBER-END-NOT-DETECTED-RX |
Fiber End Not Detected - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-FIBER-END-NOT-DETECTED-TX |
Fiber End Not Detected - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-HYBRID-FAR-END-IN-PROGRESS |
OTDR Hybrid Scan Is In Progress On Remote Side |
Alarm |
MAINTENANCE |
|
OTDR-HYBRID-SCAN-IN-PROGRESS-RX |
OTDR Hybrid Scan Is In Progress - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-HYBRID-SCAN-IN-PROGRESS-TX |
OTDR Hybrid Scan Is In Progress - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-LOSS-THR-EXCEEDED |
OTDR Loss Threshold Exceeded |
Alarm |
MAINTENANCE |
|
OTDR-ORL-THRESHOLD-EXCEEDED-RX |
ORL Exceeded Threshold - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ORL-THRESHOLD-EXCEEDED-TX |
ORL Exceeded Threshold - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ORL-TRAINING-FAILED-RX |
ORL Training Failed - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ORL-TRAINING-FAILED-TX |
ORL Training Failed - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ORL-TRAINING-IN-PROGRESS-RX |
ORL Training Is In Progress - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-ORL-TRAINING-IN-PROGRESS-TX |
ORL Training Is In Progress - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-OTDR-TRAINING-FAILED-RX |
OTDR Training Failed - RX Direction |
Alarm |
MAINTENANCE |
|
OTDR-OTDR-TRAINING-FAILED-TX |
OTDR Training Failed - TX Direction |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-FAILED |
OTDR Scan Failed |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-FAILED-RX |
OTDR Scan Failed RX |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-FAILED-TX |
OTDR Scan Failed TX |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-IN-PROGRESS |
OTDR Scan Is In Progress |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-IN-PROGRESS-RX |
OTDR Scan In Progress RX |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-IN-PROGRESS-TX |
OTDR Scan In Progress TX |
Alarm |
MAINTENANCE |
|
OTDR-SCAN-NOT-COMPLETED |
OTDR Scan Not Completed |
Alarm |
MAINTENANCE |
|
OTN-XP-DP-FPD-PKG-MISSING |
OTN XP Data Plane FPD Package Missing |
Alarm |
SYSTEM |
|
OTNSEC-LOCALLY-SECURED |
OTNSEC Locally Secured |
Alarm |
SECURITY |
|
OTUK-AIS |
OTUk: Alarm Indication Signal |
Alarm |
TRANSPORT |
|
OTUK-BDI |
OTUk: SM Backward Defect Indication |
Alarm |
TRANSPORT |
|
OTUK-BIAE |
OTUk: SM Backward Incoming Alignment Error |
Alarm |
TRANSPORT |
|
OTUK-IAE |
OTUk: Incoming Alignment Error |
Alarm |
TRANSPORT |
|
OTUK-LOF |
OTUk: Loss Of Frame |
Alarm |
TRANSPORT |
|
OTUK-LOM |
OTUK Loss Of MultiFrame |
Event |
TRANSPORT |
|
OTUK-SD |
OTUk: Signal Degrade |
Alarm |
TRANSPORT |
|
OTUK-SF |
OTUk: Signal Failure |
Alarm |
TRANSPORT |
|
OTUK-TIM |
OTUk: Trail Trace Identifier Mismatch |
Alarm |
TRANSPORT |
|
OVER-TEMP-UNIT-PROT |
Over Temperature Unit Protected |
Alarm |
EQUIPMENT |
|
PARAM-MISM |
Plug-in Module Range Settings Mismatch |
Alarm |
OPTICAL |
|
PARTIAL-TOPOLOGY |
APC Partial topology |
Alarm |
OPTICAL |
|
PATCH-ACTIVATION-FAILED |
Patch Activation Failed |
Alarm |
SYSTEM |
|
PATCH-DOWNLOAD-FAILED |
Patch Download Failed |
Alarm |
SYSTEM |
|
PCS-ERROR |
PCS Error/Invalid |
Alarm |
TRANSPORT |
|
PEER-CERT-VERIFICATION-FAILED |
Peer card certificate verification failed |
Alarm |
TRANSPORT |
|
PEER-CSF |
Peer Port Client Signal Fail Detected |
Alarm |
TRANSPORT |
|
PEX-SWITCH-ACCESS-FAILURE |
PEX Switch Access Failure |
Alarm |
EQUIPMENT |
|
PM-TCA |
Performance Monitor Threshold Crossing Alert |
Event |
TCA |
|
PMD-DEG |
PMD Degrade |
Alarm |
OPTICAL |
|
PMI |
Payload Missing Indication |
Alarm |
OPTICAL |
|
PORT-COMM-FAIL |
Module Communication Failure |
Alarm |
EQUIPMENT |
|
POWER-MODULE-FAN-OUT-OF-TOLERANCE |
Power Module: fan out of tolerance |
Alarm |
EQUIPMENT |
|
POWER-MODULE-FAN-OUT-OF-TOLERANCE-WARNING |
Power Module Warning: fan out of tolerance |
Alarm |
EQUIPMENT |
|
POWER-MODULE-OUTPUT-DISABLED |
Power Module Output Disable |
Alarm |
EQUIPMENT |
|
POWER-MODULE-REDUNDANCY-LOST |
Power Module Redundancy lost |
Alarm |
EQUIPMENT |
|
POWER-OFF |
Card In Power Off Status |
Alarm |
EQUIPMENT |
|
POWER-ON-TIMEOUT |
Card In Power On Timeout |
Alarm |
EQUIPMENT |
|
PPM-MISMATCH |
Incompatible pluggable inserted in the port |
Alarm |
EQUIPMENT |
|
PRBS-ENABLED |
PRBS Generation Enabled |
Alarm |
TRANSPORT |
|
PROT-CONFIG-MISMATCH |
Protection Card Configuration Mismatch |
Alarm |
PROTECTION |
|
PROT-SOFT-VERIF-FAIL |
Protect Volume Software Signature Verification Failed |
Alarm |
SECURITY |
|
PROTNA |
Protection Unit Not Available |
Alarm |
EQUIPMENT |
|
PROV-FAILED |
Provisioning Failed |
Alarm |
SYSTEM |
|
PROV-IN-PROG |
Provisioning In Progress |
Event |
TRANSPORT |
|
PROV-INCOMPATIBLE |
Incompatible Provision |
Alarm |
EQUIPMENT |
|
PROV-INPROGRESS |
Provisioning In Progress |
Alarm |
SYSTEM |
|
PROV-MISMATCH |
Provisioning Mismatch |
Alarm |
EQUIPMENT |
|
PROV-MISMATCH |
Provisioning Mismatch |
Alarm |
EQUIPMENT |
|
PSD-FAILED |
Failure in Power Spectrum Distribution |
Alarm |
OPTICAL |
|
PSWD-CHG-REQUIRED |
User Password Change Required |
Event |
SECURITY |
|
PTIM |
Payload Type Identifier Mismatch |
Alarm |
TRANSPORT |
|
PWR |
Power Failure at Connector |
Alarm |
EQUIPMENT |
|
PWR-CON-LMT |
Power Consumption Limit Has Crossed |
Alarm |
EQUIPMENT |
|
PWR-ERROR |
Power Module Error (PM_VIN_VOLT_OOR) |
Alarm |
EQUIPMENT |
|
PWR-EXCEEDS |
Power reservation exceeds configured power |
Alarm |
EQUIPMENT |
|
PWR-EXCEEDS-CAPACITY |
Power reservation exceeds configured power capacity |
Alarm |
EQUIPMENT |
|
PWR-FAIL-A |
Equipment power failure at connector A |
Alarm |
EQUIPMENT |
|
PWR-FAIL-B |
Equipment power failure at connector B |
Alarm |
EQUIPMENT |
|
PWR-FAIL-RET-A |
Equipment power failure at return connector A |
Alarm |
EQUIPMENT |
|
PWR-FAIL-RET-B |
Equipment power failure at return connector B |
Alarm |
EQUIPMENT |
|
PWR-GRP-REDUNDANCY-LOST |
Power Group Redundancy lost |
Alarm |
EQUIPMENT |
|
PWR-MISMATCH |
PEM PID mismatch in the chassis |
Alarm |
EQUIPMENT |
|
PWR-OUTPUT-DISABLED |
Power Module Output Disabled (PM_OUTPUT_DISABLED) |
Alarm |
EQUIPMENT |
|
PWR-PROT-ON |
Raman Power Protection On |
Alarm |
OPTICAL |
|
PWRRESTART |
Powerfail Restart |
Alarm |
EQUIPMENT |
|
RACK-OBFL-ERROR |
Obfl error |
Alarm |
EQUIPMENT |
|
RAMAN-AMPLI-OSRI |
Raman Amplifier Optical Safety Remote Interlock |
Alarm |
OPTICAL |
|
RAMAN-CALIBRATION-FAILED |
Raman Calibration Failed |
Alarm |
OPTICAL |
|
RAMAN-CALIBRATION-PENDING |
Raman Calibration Pending |
Alarm |
OPTICAL |
|
RAMAN-CALIBRATION-RUNNING |
Raman Calibration Running |
Alarm |
OPTICAL |
|
RAMAN-GAIN-NOT-REACHED |
Raman Gain Not Reached |
Alarm |
OPTICAL |
|
RAMAN-TURNUP-FAIL |
Raman Pumps Turnup Fail |
Alarm |
OPTICAL |
|
RDI-L |
Remote Defect Indication Line |
Alarm |
TRANSPORT |
|
REMOTE-CERT-FAIL |
RemoteCard Certificate Validation Failed |
Alarm |
TRANSPORT |
|
REMOTE-DEG-SER |
Remote FEC Degraded Symbol Error Rate |
Event |
TRANSPORT |
|
REMOTE-FAULT |
Remote Fault |
Alarm |
TRANSPORT |
|
REROUTE-IN-PROG |
Reroute In Progress |
Alarm |
PROTECTION |
|
RESOURCE-ALLOC-FAIL |
Resource Allocation Failed |
Alarm |
EQUIPMENT |
|
RESOURCES-GONE |
No More Resources Available |
Alarm |
EQUIPMENT |
|
RESOURCES-LOW |
Running Low On Resources |
Alarm |
SYSTEM |
|
RESTORE-IN-PROG |
Restoration in Progress |
Alarm |
PROTECTION |
|
REVERT-IN-PROG |
Revert In Progress |
Alarm |
PROTECTION |
|
RFI |
Remote Failure Indication |
Alarm |
OPTICAL |
|
RLS |
Raman Laser Shutdown |
Alarm |
OPTICAL |
|
RMON-ALARM |
RMON Threshold Crossing Alarm |
Event |
OPTICAL |
|
RMON-RESET |
RMON Histories And Alarms Reset Reboot |
Event |
OPTICAL |
|
ROLE-SWITCH-ACTIVE |
Role is Switched to active |
Event |
SYSTEM |
|
ROUTE-OVERFLOW |
OSPF Routing Table Overflow |
Alarm |
SYSTEM |
|
RS-EOC |
Regenerator Section - DCC Termination Failure |
Alarm |
TRANSPORT |
|
RS-TIM |
Regenerator Section Trace Identifier Mismatch |
Alarm |
TRANSPORT |
|
RUNNING-FANS-AT-MAX-SPEED |
FANs Running At Maximum Speed |
Alarm |
EQUIPMENT |
|
RX-BELOW-MIN-PSD |
Receive Channel Power Below Minimum Power Spectral Density |
Alarm |
OPTICAL |
|
SD |
Signal Degrade |
Alarm |
OPTICAL |
|
SD-L |
BER Threshold Exceeded For Signal Degrade Line |
Alarm |
TRANSPORT |
|
SENSOR-HIGH-0-6V-CPU-A |
0.6V-CPU-A sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-0-6V-CPU-B |
0.6V-CPU-B sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-05V-CPU |
1.05V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-0V |
1.0V sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-0V-PHY |
1.0V-PHY sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-2V |
1.2V sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-2V-CPU |
1.2V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-3V-CPU |
1.3V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-5V-CPU |
1.5V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-7V-CPU |
1.7V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-82V-CPU |
1.82V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-1-8V |
1.8V sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-2-5V |
2.5V sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-3-3V |
3.3V sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-3-3V-CPU |
3.3V-CPU sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-3-3V-STBY |
3.3V-STBY sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-5-0V-STBY |
5.0V-STBY sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-BP-48V |
BP-48V sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-CPU-TEMP |
CPU-TEMP sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-DDR-CH0-TEMP |
DDR-CH0-TEMP sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-DDR-CH1-TEMP |
DDR-CH1-TEMP sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-ETHERNET-SWITCH-TEMP |
ETHERNET-SWITCH-TEMP sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-HOTSPOT1 |
HOTSPOT1 sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-HOTSPOT2 |
HOTSPOT2 sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-INLET-AIR |
INLET-AIR sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-HIGH-OUTLET-AIR |
OUTLET-AIR sensor high |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-0-6V-CPU-A |
0.6V-CPU-A sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-0-6V-CPU-B |
0.6V-CPU-B sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-05V-CPU |
1.05V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-0V |
1.0V sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-0V-PHY |
1.0V-PHY sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-2V |
1.2V sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-2V-CPU |
1.2V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-3V-CPU |
1.3V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-5V-CPU |
1.5V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-7V-CPU |
1.7V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-82V-CPU |
1.82V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-1-8V |
1.8V sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-2-5V |
2.5V sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-3-3V |
3.3V sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-3-3V-CPU |
3.3V-CPU sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-3-3V-STBY |
3.3V-STBY sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-5-0V-STBY |
5.0V-STBY sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-BP-48V |
BP-48V sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-CPU-TEMP |
CPU-TEMP sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-DDR-CH0-TEMP |
DDR-CH0-TEMP sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-DDR-CH1-TEMP |
DDR-CH1-TEMP sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-ETHERNET-SWITCH-TEMP |
ETHERNET-SWITCH-TEMP sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-HOTSPOT1 |
HOTSPOT1 sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-HOTSPOT2 |
HOTSPOT2 sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-INLET-AIR |
INLET-AIR sensor low |
Alarm |
EQUIPMENT |
|
SENSOR-LOW-OUTLET-AIR |
OUTLET-AIR sensor low |
Alarm |
EQUIPMENT |
|
SESSION-TIME-LIMIT |
Session Time Limit Expired |
Event |
SECURITY |
|
SF |
Signal Failure |
Alarm |
OPTICAL |
|
SF-L |
BER Threshold Exceeded For Signal Failure Line |
Alarm |
OPTICAL |
|
SFTWDOWN |
Software Download In Progress |
Alarm |
SYSTEM |
|
SFTWDOWN-FAIL |
Software Download Failed |
Alarm |
SYSTEM |
|
SHELF-COMM-FAIL |
Shelf Communication Failure |
Alarm |
EQUIPMENT |
|
SIGLOSS |
Signal Loss on Data Interface |
Alarm |
OPTICAL |
|
SIGNAL-OSC-SPAN-LOSS-DIFF-OUT-OF-RANGE |
Difference in Rx OSC span loss and Rx signal span loss exceeded threshold |
Alarm |
OPTICAL |
|
SIP |
Startup In Progress |
Alarm |
TRANSPORT |
|
SNTP-HOST |
NTP/SNTP Host Failure |
Alarm |
SYSTEM |
|
SOFT-VERIF-FAIL |
Software Signature Verification Failed |
Alarm |
SYSTEM |
|
SPAN-LOSS-BASELINE-DEVIATION-OUT-OF-RANGE |
Rx span loss deviated from baselin |
Alarm |
OPTICAL |
|
SPAN-LOSS-OUT-OF-RANGE |
Span Loss Value Out Of Range |
Alarm |
OPTICAL |
|
SPAN-NOT-MEASURED |
Span Measurement Cannot Be Performed |
Alarm |
OPTICAL |
|
SPAN-TOO-SHORT |
OTS Span Too Short |
Alarm |
OPTICAL |
|
SPECTRUM-VIOLATED |
Spectrum is Violated |
Alarm |
OPTICAL |
|
SQUELCHED |
Equipment Squelched |
Alarm |
TRANSPORT |
|
SSD-ATA-ERRORS |
CPU SSD ATA Error |
Alarm |
EQUIPMENT |
|
SSD-HI-TEMP |
CPU SSD High Temperature |
Alarm |
EQUIPMENT |
|
SSM-DUS |
Do Not Use For Synchronization |
Alarm |
TIMING |
|
SSM-FAIL |
Failed To Receive Synchronization Status Message |
Alarm |
TIMING |
|
SSM-LNC |
G812L - Local Node Clock traceable |
Alarm |
TIMING |
|
SSM-OFF |
Synchronization Status Messages Are Disabled On This Interface |
Alarm |
TIMING |
|
SSM-PRC |
G811 - Primary Reference Clock traceable |
Alarm |
TIMING |
|
SSM-PRS |
Stratum 1 Primary Reference Source Traceable |
Alarm |
TIMING |
|
SSM-RES |
Reserved For Network Synchronization Use |
Alarm |
TIMING |
|
SSM-SDH-TN |
G812T - Transit Node Clock traceable |
Alarm |
TIMING |
|
SSM-SETS |
G813 - Synchronous Equipment Timing Source traceable |
Alarm |
TIMING |
|
SSM-SMC |
SONET Minimum Clock Traceable |
Alarm |
TIMING |
|
SSM-ST2 |
Stratum 2 Traceable |
Alarm |
TIMING |
|
SSM-ST3 |
Stratum 3 Traceable |
Alarm |
TIMING |
|
SSM-ST3E |
Stratum 3E Traceable |
Alarm |
TIMING |
|
SSM-ST4 |
Stratum 4 Traceable |
Alarm |
TIMING |
|
SSM-STU |
Synchronized - Traceability Unknown |
Alarm |
TIMING |
|
SSM-TNC |
Transit Node Clock Traceable |
Alarm |
TIMING |
|
SW-MISMATCH |
Software Mismatch |
Alarm |
SYSTEM |
|
SWTOPRI |
Switch To Primary Reference |
Alarm |
TIMING |
|
SWTOSEC |
Switch To Second Reference |
Alarm |
TIMING |
|
SWTOTHIRD |
Switch To Third Reference |
Alarm |
TIMING |
|
SYNC-FREQ |
Synchronization Reference Frequency Out Of Bounds |
Alarm |
TIMING |
|
SYNCCLK |
Synchronization Unit Failure |
Alarm |
TIMING |
|
SYNCLOSS |
Synchronization Loss on Data Interface |
Alarm |
TIMING |
|
SYNCPRI |
Primary Synchronization Reference Failure |
Alarm |
TIMING |
|
SYNCPRI |
Primary Synchronization Reference Failure |
Alarm |
TIMING |
|
SYNCSEC |
Secondary Synchronization Reference Failure |
Alarm |
TIMING |
|
SYNCTHIRD |
Third Synchronization Reference Failure |
Alarm |
TIMING |
|
SYSBOOT |
System Reboot |
Alarm |
SYSTEM |
|
TD-FAILED |
Tone Detection Failed |
Event |
MAINTENANCE |
|
TD-INPROGRESS |
Tone Detection In Progress |
Alarm |
MAINTENANCE |
|
TD-LASER-ON |
Tone Detection Laser is ON |
Event |
MAINTENANCE |
|
TD-SUCCESS |
Tone Detection Success |
Event |
MAINTENANCE |
|
TEMP-LIC |
Temporary License Is In Use |
Alarm |
SYSTEM |
|
TEMP-MISM |
Temperature Reading Mismatch Between SC Cards |
Alarm |
EQUIPMENT |
|
TEMPERATURE |
Temperature out of working range |
Alarm |
EQUIPMENT |
|
TG-INPROGRESS |
Tone Generation In Progress |
Alarm |
MAINTENANCE |
|
TIM-S |
Section Trace Identifier Mismatch |
Alarm |
TRANSPORT |
|
TRAF-AFFECT-RESET-REQUIRED |
Traffic Affecting Reset Required |
Alarm |
EQUIPMENT |
|
TRAF-AFFECT-SEC-UPG-REQUIRED |
Traffic Affecting Security Upgrade Required |
Alarm |
EQUIPMENT |
|
TRAIL-SIGNAL-FAIL |
Trail Signal Fail |
Alarm |
TRANSPORT |
|
TRUNK-ODU-AIS |
Trunk ODU Alarm Indication Signal |
Alarm |
TRANSPORT |
|
TRUNK-OPU-CSF |
Trunk OPU Client Signal Fail |
Alarm |
TRANSPORT |
|
TRUNK-PAYLOAD-MISM |
Trunk Payload Type Mismatch |
Alarm |
TRANSPORT |
|
TX-POWER-PROV-MISMATCH |
Provisioned Optics Transmit Power Not Supported |
Event |
TRANSPORT |
|
UNC-WORD |
FEC Uncorrected Word |
Alarm |
TRANSPORT |
|
UNIT-HIGH-TEMP |
Unit High Temperature |
Alarm |
EQUIPMENT |
|
UNQUAL-PPM |
Unqualified PPM Inserted |
Alarm |
EQUIPMENT |
|
UNTRUSTED-APPLICATION |
Trust Not Established With CSLU/CSSM |
Alarm |
SYSTEM |
|
USAGE-NOT-REPORTED |
Licenses Usage Is Not Reported |
Alarm |
SYSTEM |
|
USB-MOUNT-FAIL |
USB Mount Failure |
Alarm |
EQUIPMENT |
|
USB-OC-1 |
USB 1 Over Current |
Alarm |
EQUIPMENT |
|
USB-OC-2 |
USB 2 Over Current |
Alarm |
EQUIPMENT |
|
USB-PORTS-DOWN |
USB Ports in ECU are not functional |
Event |
EQUIPMENT |
|
USB-WRITE-FAIL |
USB Write Failure |
Alarm |
EQUIPMENT |
|
USBSYNC |
USB Sync in Progress |
Alarm |
EQUIPMENT |
|
USER-LOCKOUT |
User Locked Out |
Event |
SECURITY |
|
USER-LOGIN |
Login of User |
Event |
SECURITY |
|
USER-LOGOUT |
Logout of User |
Event |
SECURITY |
|
VOA-DISABLED |
VOA Control Loop Disable Due To Excessive Counter-Propagation Light |
Alarm |
OPTICAL |
|
VOA-HDEG |
Variable Optical Attenuator Degrade High |
Alarm |
OPTICAL |
|
VOA-HFAIL |
Variable Optical Attenuator Failure High |
Alarm |
OPTICAL |
|
VOA-LDEG |
Variable Optical Attenuator Degrade Low |
Alarm |
OPTICAL |
|
VOA-LFAIL |
Variable Optical Attenuator Failure Low |
Alarm |
OPTICAL |
|
VOLT-MISM |
Voltage Reading Mismatch Between SC Cards |
Alarm |
EQUIPMENT |
|
WKSWBK |
Switched Back To Working |
Event |
PROTECTION |
|
WKSWPR |
Switched To Protection |
Alarm |
PROTECTION |
|
WRK-PATH-RECOVERY-CHECK |
Checking For Work Path Recovery |
Alarm |
PROTECTION |
|
WRMRESTART |
Warm Restart |
Event |
SYSTEM |
|
WTR |
Wait To Restore |
Alarm |
PROTECTION |
|
WVL-MISMATCH |
Equipment Wavelength Mismatch |
Alarm |
OPTICAL |
|
WVL-UNLOCKED |
Wavelength Unlocked |
Alarm |
OPTICAL |
|
XGE-EEPROM-ERROR |
XGE EEPROM Error |
Alarm |
EQUIPMENT |
|
XGE-FLASH-ERROR |
XGE Flash Error |
Alarm |
EQUIPMENT |
|
T-BAD-SH |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBE-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBE-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBE-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBE-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBEL |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBER-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBER-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBER-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBER-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-BBES |
Threshold Crossing Alert |
Event |
TCA |
|
T-BIEC |
Threshold Crossing Alert |
Event |
TCA |
|
T-BIP |
Threshold Crossing Alert |
Event |
TCA |
|
T-BIT-EC |
Threshold Crossing Alert |
Event |
TCA |
|
T-BYTE-EC |
Threshold Crossing Alert |
Event |
TCA |
|
T-CDPM-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-CDPM-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-CDPM-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-CHROM-DISP |
Threshold Crossing Alert |
Event |
TCA |
|
T-CVL |
Threshold Crossing Alert |
Event |
TCA |
|
T-CVS |
Threshold Crossing Alert |
Event |
TCA |
|
T-DGD-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-DGD-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-EC-WORD |
Threshold Crossing Alert |
Event |
TCA |
|
T-ES-PCS |
Threshold Crossing Alert |
Event |
TCA |
|
T-ES-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-ES-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-ES-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-ES-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-ESL |
Threshold Crossing Alert |
Event |
TCA |
|
T-ESR-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-ESR-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-ESR-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-ESR-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-ESS |
Threshold Crossing Alert |
Event |
TCA |
|
T-FC-L |
Threshold Crossing Alert |
Event |
TCA |
|
T-FC-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-FC-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-FC-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-FC-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-FRM-ERR |
Threshold Crossing Alert |
Event |
TCA |
|
T-GAIN-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-GAIN-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-GAIN-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-LASER-BIAS-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-LASER-BIAS-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-LASER-TEMP-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-LASER-TEMP-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-LOW-FREQ-OFF-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-LOW-FREQ-OFF-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-LOW-FREQ-OFF-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-BBE |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-BBER |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-EB |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-ES |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-ESR |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-FC |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-LOSS |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-SES |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-SESR |
Threshold Crossing Alert |
Event |
TCA |
|
T-MS-UAS |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPBR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPBR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPBR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPBRR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPBRR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPBRR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPT-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPT-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPT-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPWR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPWR-CL-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPWR-CL-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPWR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OPWR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OSC-PWR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OSC-PWR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OSC-PWR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-OSNR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-OSNR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-OSNR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-PCR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-PCR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-PCR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-PDL-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-PDL-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-PDL-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-PMD-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-PMD-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-PN-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-PN-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-POST-FEC-BER-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-POST-FEC-BER-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-PRE-FEC-BER-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-PRE-FEC-BER-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-PWR-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-PWR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-PWR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-Q-MARGIN-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-Q-MARGIN-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-Q-MARGIN_INST-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-Q-MARGIN_INST-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-Q-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-Q-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-RAMAN-BR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-RAMAN-BR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-RAMAN-BRR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-RAMAN-BRR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-BBE |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-BBER |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-EB |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-ES |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-ESR |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-OFS |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-SES |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-SESR |
Threshold Crossing Alert |
Event |
TCA |
|
T-RS-UAS |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-PWR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-PWR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-SIG-POW-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-SIG-POW-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-SIG-POW-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-TEMP-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-RX-TEMP-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-SEFS |
Threshold Crossing Alert |
Event |
TCA |
|
T-SES-PCS |
Threshold Crossing Alert |
Event |
TCA |
|
T-SES-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-SES-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-SES-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-SES-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-SESL |
Threshold Crossing Alert |
Event |
TCA |
|
T-SESR-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-SESR-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-SESR-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-SESR-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-SESS |
Threshold Crossing Alert |
Event |
TCA |
|
T-SIG-SPAN-LOSS-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-SIG-SPAN-LOSS-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-SOPMD-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-SOPMD-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-SOPMD-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-TILT-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-TILT-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-TOT-SPAN-LOSS-CL-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-TOT-SPAN-LOSS-CL-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-TOT-SPAN-LOSS-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-TOT-SPAN-LOSS-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-TX-PWR-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-TX-PWR-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-UAS-PCS |
Threshold Crossing Alert |
Event |
TCA |
|
T-UAS-PM |
Threshold Crossing Alert |
Event |
TCA |
|
T-UAS-SM |
Threshold Crossing Alert |
Event |
TCA |
|
T-UAS-TCM1 |
Threshold Crossing Alert |
Event |
TCA |
|
T-UAS-TCM2 |
Threshold Crossing Alert |
Event |
TCA |
|
T-UASL |
Threshold Crossing Alert |
Event |
TCA |
|
T-UASS |
Threshold Crossing Alert |
Event |
TCA |
|
T-UNC-WORDS |
Threshold Crossing Alert |
Event |
TCA |
|
T-VOA-AVG |
Threshold Crossing Alert |
Event |
TCA |
|
T-VOA-MAX |
Threshold Crossing Alert |
Event |
TCA |
|
T-VOA-MIN |
Threshold Crossing Alert |
Event |
TCA |
|
T-GFPSTATSROUNDTRIPLATENCYUSEC |
Threshold Crossing Alert |
Event |
TCA |
|
T-RXCONTROLFRAMES |
Threshold Crossing Alert |
Event |
TCA |
|
T-RXPAUSEFRAMES |
Threshold Crossing Alert |
Event |
TCA |
|
T-RXPKTSDROPPEDINTERNALCONGESTION |
Threshold Crossing Alert |
Event |
TCA |
|
T-RXUNKNOWNOPCODEFRAMES |
Threshold Crossing Alert |
Event |
TCA |
|
T-TXPAUSEFRAMES |
Threshold Crossing Alert |
Event |
TCA |
|
T-TXPKTSDROPPEDINTERNALCONGESTION |
Threshold Crossing Alert |
Event |
TCA |
|
NODE-DISCONNECT |
Controller system disconnected from node |
Alarm |
CONC_SYSTEM |
|
BACKUP-FAILURE |
Controller system Database Backup Creation is failed |
Alarm |
CONC_SYSTEM |
|
UPLOAD-FAILURE |
Controller system Database Backup File Upload to SFTP is failed |
Alarm |
CONC_SYSTEM |
|
NODE-BACKUP-FAILURE |
Node Database Backup creation failed |
Alarm |
CONC_SYSTEM |
Feedback