Please add breadcrumbs in author

About Fabric Overview for LAN Operational Mode Setups, Release 12.1.3

Tech Article
 
Last updated: April 8, 2024
PDF
Is this helpful? Feedback

New and Changed Information

The following table provides an overview of the significant changes up to this current release. The table does not provide an exhaustive list of all changes or of the new features up to this release.

Release Version Feature Description

NDFC release 12.1.3

Reorganized content

Content within this document was originally provided in the Cisco NDFC-Fabric Controller Configuration Guide or the Cisco NDFC-SAN Controller Configuration Guide. Beginning with release 12.1.3, this content is now provided solely in this document and is no longer provided in those documents.

Fabric Overview

The Actions drop-down list at the Fabric level allows you to perform the following:

Actions Description

Edit Fabric

  • To edit a fabric, choose Actions > Edit Fabric.

  • The Edit fabric window appears, do necessary changes and click Save.

Add Switches

Refer to Add Switches: LAN for more information.

Recalculate Config

Refer to the section "Recalculating and Deploying Configurations" in the Campus VXLAN EVPN article for more information.

Preview Config

Refer to the section "Previewing Switches" in the Add Switches: LAN for more information.

Deploy Config

  • To deploy configuration changes, choose Actions > Deploy Config.

  • A progress window appears and confirmation message is displayed.

More

Deployment Enable

  • From Fabrics Overview, choose Actions on main tab, choose More > Deployment Enable.

  • A confirmation window appears, click OK.

Deployment Disable

  • From Fabrics Overview, choose Actions on main tab, choose More > Deployment Disable.

  • A confirmation window appears, click OK.

Backup Fabric

Refer to the "Backup Fabric" section in Backup and Restore: LAN for more information.

Restore Fabric

Refer to the "Restore Fabric" section in Backup and Restore: LAN for more information.

VXLAN OAM

Refer to Configuring VXLAN OAM for more information.

note.svg

This feature appears in the Actions drop-down list only for VXLAN Fabric, eBGP VXLAN Fabric, External, and Lan Classic fabric technologies, which support VXLAN OAM.


Configure End Point Locator

The Endpoint Locator (EPL) feature allows real-time tracking of endpoints within a data center. For more information, see Endpoint Locator.

Fabric Overview contains tabs that allows you view and perform all the operations on the fabric.

Overview

The Overview tab displays the following information as cards.

  • Fabric Information

  • Fabrics

    Displayed if there are child fabrics. For example: Multi-Site Fabrics

  • Event Analytics

  • Switches Configuration

  • Switches

    • Switch Health

    • Switch Configuration

    • Switch Roles

    • Switch Hardware Version

  • VXLAN

    Displayed only for VXLAN Fabrics

    • Routing Loopback

    • VTEP Loopback

    • Multisite Loopback

    • NVE Int Status

    • Networks/VRFs Definition

    • Extended Networks/VRFs

  • Hosts

    This tab is displayed only if you’ve configured IPFM fabric.

  • Flows

    This tab is displayed only if you’ve configured IPFM fabric.

  • Reports

Hosts Card

The Hosts card displays the following details:

  • Pie chart - Each slice has a unique color and displays a host role and count, for example, Sender, Receiver, and ARP. Click a host type, for example, Sender, to hide or unhide the slice, for the selected IPFM fabric.

    To view more information, choose Fabric Overview > Hosts > Discovered Hosts.

  • Faults - If faults exist, displays the number of faults including policer drops. To view more information, click Faults which opens the Hosts > Discovered Hosts tab.

For more information about hosts, see Hosts.

Flows Card

The Flows card displays the following details:

  • Pie chart - Each slice has a unique color and displays a multicast flow class and count, for example, Active, Inactive, Sender Only, and Receiver Only. Click a flow class, for example, Active, to hide or unhide the slice.

    To view more information, choose Fabric Overview > Flows > Flow Status.

  • Groups - Displays the number of multicast flow groups. This information is also displayed on the IPFM fabric topology.

For more information about flows, see Flows.

Switches

You can manage switch operations in this tab. Each row represents a switch in the fabric, and displays switch details, including its serial number.

Some of the actions that you can perform from this tab are also available when you right-click a switch in the fabric topology window. However, the Switches tab enables you to provision configurations on multiple switches, like deploying policies, simultaneously.

note.svg

For all non-nexus device only MD5 protocol option is supported for SNMPv3 authentication.


The Switches tab has following information of every switch you discover in the fabric:

  • Switch: Specifies the switch name.

  • IP Address: Specifies the IP address of the switch.

  • Role: Specifies the role of the switch.

  • Serial Number: Specifies the serial number of the switch.

  • Mode: Specifies the current mode of the switch.

  • Config Status: Specifies the configuration status. Status will be either In-Sync or Out-of-sync.

  • Oper Status: Specifies the operation health status of the switch.

  • Discovery Status: Specifies the discovery status of the switch. After the discovery of the device, the discovery status changes to Ok in green.

  • Model: Specifies the switch model.

  • vPC Role: Specifies the vPC role of the switch.

  • vPC Peer: Specifies the vPC peer of the switch.

  • Software Version: Specifies the software version of the switch.

  • Up Time: Specifies the number of days and time since the switch is online.

The Switches tab has the following operations on the Action drop-down list:

  • Add switches: Click this icon to discover existing or new switches to the fabric.

    This option is also available in the LAN > Switches page. Choose Actions > Add switches discover and add switches to the fabric.

    Refer the following sections for more information:

    • "Adding Switches" section in BGP Fabric : Provides information on adding switches to easy fabrics.

    • "Discovering New Switches" section in External Connectivity Network: Provides information on adding Cisco Nexus switches to external fabrics.

    • "Adding Non-Nexus Devices to External Fabrics" section in External Connectivity Network: Provides information on adding non-Nexus switches to external fabrics.

  • Preview: You can preview the pending configurations and the side-by-side comparison of running configurations and expected configurations.

  • Deploy: Deploy switch configurations. You can deploy configurations for multiple devices using the Deploy button.

    note.svg

    This option grays out if the fabric is in freeze mode, that is, if you have disabled deployments on the fabric.
    In a VXLAN Multi-site fabric, you can deploy configurations only on the Border Gateway, Border Gateway Spine, Border Gateway Super Spine, or External Fabric switches.


  • Discovery: You can perform the following operations.

    • Update Credentials: Updates device credentials such as authentication protocol, username, and password.

    • Rediscover: Initiates the switch discovery process by Nexus Dashboard Fabric Controller afresh.

    • Change Discovery IP: Changes the discovery IP address for the switches.

    • Update VRF: Enables auto discovery of the VRFs associated with the interface of the switch with a discovery IP address, when importing a switch.

  • Set Role: Assigns roles for one or more devices of the same device type. The device types are:

    • NX-OS

    • IOS XE

    • IOS XR

    • Other

      Ensure that you have moved switches from maintenance mode to active mode or operational mode before setting roles.

      The following are the device roles supported for non-Nexus devices:

    • Spine

    • Leaf

    • Edge Router (Use this role for VRF-Lite).

    • Core Router

    • Super Spine

    • ToR

      You can change the switch role from an existing role to a supported role if there are no overlays on the switches. Click Recalculate and Deploy to generate the updated configuration. The following changes are allowed for a switch role:

      Table 1. Supported Switch Role Changes

      Leaf to Border

      Border to Leaf

      Leaf to Border Gateway

      Border Gateway to Leaf

      Border to Border Gateway

      Border Gateway to Border

      Spine to Border Spine

      Border Spine to Spine

      Spine to Border Gateway Spine

      Border Gateway Spine to Spine

      Border Spine to Border Gateway Spine

      Border Gateway Spine to Border Spine

      You cannot change the switch role from any leaf role to any spine role and from any spine role to any leaf role. In case the switch role is not changed according to the allowed changes mentioned above, an error message is displayed after you deploy.

      Switch[<serial-number>]: Role change from <switch-role> to <switch-role> is not permitted.

      You can change the switch role to the role that was set earlier, or set a new role, and configure the fabric.

      If you have not created any policy template instances before performing Recalculate and Deploy, and there are no overlays, you can change the role of a switch to any other required role.

      If you change the switch role of a vPC switch that is part of a vPC pair, the following error appears when you perform Recalculate and Deploy. To prevent this scenario, change the switch roles of both the switches in the vPC pair to the same role.

    The switch role should be the same for VPC pairing. peer1 <serial-number>: [<switch-role>], peer2
  • vPC Pairing: Choose a switch and click vPC Pairing to create, edit, or unpair a vPC pair. Use this option only when you choose a Cisco Nexus switch. For more information on how to create a vPC pair in external fabrics, see Creating a vPC Setup in the External Fabric.

    note.svg

    NDFC 12 does not allow you to create vPC pairing on Spine, Border Spine, Border Gateway Spine, Super Spine, Border Super Spine, and Border Gateway Super Spine roles.


  • ToR/Access Pairing: Enables ToR to Leaf pairing for the switches.

  • vPC Overview: Enables you to configure a vPC pair for the selected switch.

  • More: Further operations are provided under More.

    • Change Mode: You can change the mode of a switch from Normal to Managed and vice versa.

      You can choose to save the settings and deploy immediately or schedule it for later.

    • Provision RMA: Allows you to replace a physical switch in a fabric when using Cisco Nexus Dashboard Fabric Controller Easy Fabric mode.

    • Change Serial Number: Allows you to change switch serial number if the switches are pre-provisioned.

      While pre-provisioning devices, you can provide dummy values for the Serial number of the switch. After configuring network for preprovisioned devices in the form of policies, or links, or interfaces, or VRFs, or networks, the dummy serial number can be changed with the required appropriate serial number. Before changing the serial number of the switches, choose Actions > Recalculate and deploy to save the latest data on switch.

      note.svg

      Change of serial number is allowed only for Nexus 9000 Series switches.


    • Copy Run Start: Performs an on-demand copy running-configuration to startup-configuration operation for one or more switches.

      note.svg

      This option will be grayed out if the fabric is in freeze mode, that is, if you have disabled deployments on the fabric.


    • Reload: Reloads the selected switch.

      note.svg

      This option is grayed out if the fabric is in freeze mode, that is, if you have disabled deployments on the fabric.


    • Restore Switch: The information you restore on a switch is extracted from the fabric backups. This does not restore any fabric intents and other configurations applied using the fabric settings. Only intents on the switch are restored. Therefore, after you restore a switch, it might go out-of-sync because the fabric intents are not restored. Perform a fabric restore to restore the intents as well. You can restore only one switch at a time. You cannot restore a switch if the fabric where it is discovered is part of an VXLAN Multi-site fabric.

    • Show Commands: Executes Show commands on the selected Switch. Select the Commands from the drop-down list. Enter appropriate values in the Variables fields and click Execute. The right column executes the show command and displays the output.

    • Exec Commands: When you first log in, the Cisco NX-OS software places you in the EXEC mode. The commands available in the EXEC mode include the show commands that display the device status and configuration information, the clear commands, and other commands that perform actions that you do not save in the device configuration.

    • Delete switches: Removes the selected switch from the fabric.

      This option will be grayed out if the fabric is in freeze mode, that is, if you have disabled deployments on the fabric.

Guidelines and Limitations for changing discovery IP Address

From Cisco Nexus Dashboard Fabric Controller Release 12.0.1a, you can change the Discovery IP address of a device that is existing in a fabric.

Guidelines and Limitations

The following are the guidelines and limitations for changing discovery IP address.

  • Changing discovery IP address is supported for NX-OS switches and devices that are discovered over their management interface.

  • Changing discovery IP address is supported for templates such as:

    • Data Center VXLAN EVPN

    • BGP Fabric

    • External

    • Classic LAN

    • LAN Monitor

  • Changing discovery IP address is supported in both managed and monitored modes.

  • Only users with the network-admin role can change the discovery IP address on Cisco Fabric Controller UI.

  • The discovery IP address must not be used on other devices, and it must be reachable when the change is done.

  • While changing the discovery IP address for a device in a managed fabric, switches are placed in migration mode.

  • When you change the IP address of a switch that is linked to vPC Peer, corresponding changes such as vPC peer, domain configuration will be updated accordingly.

  • Fabric configuration restores the original IP address, it reports out of sync post restore and the configuration intent for the device must be updated manually to get the in-sync status.

  • Fabric controllers restore that had the original device discovery IP reports the switch as Unreachable post restore. The discovery IP address change procedure must be repeated after the restore.

  • Device Alarms associated with the original discovery IP address will be purged after the change of IP address.

Changing Discovery IP Address

Before you begin:

You must make the management IP address and route related changes on the device and ensure that the reachability of the device from Nexus Dashboard Fabric Controller.

To change the discovery IP address from the Cisco Nexus Dashboard Fabric Controller Web UI, perform the following steps:

  1. Choose LAN > Fabrics.

  2. Click on fabric names to view the required switch.

    The Fabric summary slide-in pane appears.

  3. Click Launch icon to view Fabric Overview window.

  4. On the Switches tab, click Refresh icon adjacent to the Action button on the main window.

    Switch with a changed IP address will be in Unreachable state in Discovery Status column.

  5. Click the check box next to the Switch column and select the switch.

    note.svg

    You can change the IP address for individual switch and not for multiple switches.


  6. Choose Actions > Change Discovery IP on the switches tab area.

    The Change Discovery IP window appears.

    Similarly, you can navigate from LAN > Switches tab. Choose a required switch, click Actions > Discovery > Change Discovery IP.

  7. Enter the appropriate IP address in the New IP Address text field and click OK.

    1. The new IP address must be reachable from Nexus Dashboard Fabric Controller to update successfully.

    2. Repeat the above procedures for the devices where the discovery IP address must be changed before proceeding with further steps.

    3. If the fabric is in managed mode, the device mode will be updated to migration mode.

  8. From the fabric Actions drop-down list, click Recalculate Config to initiate the process of updating Nexus Dashboard Fabric Controller configuration intent for the devices. Similarly, you can recalculate configuration on topology window. Choose Topology, tab right-click on the switch, click Recalculate Config.

    The Nexus Dashboard Fabric Controller configuration intent for the device management related configuration will be updated and the device mode status for the switch is changed to normal mode. The switch configuration status is displayed as In-Sync.

    note.svg

    The PM records associated with the old switch IP address will be purged and new record collections take an hour to initiate after the changes.


You can add links between border switches of different fabrics (inter-fabric links) or between switches in the same fabric (intra-fabric links). You can only create an inter-fabric connection (IFC) for a switch that is managed by Nexus Dashboard Fabric Controller.

There are scenarios where you might want to define links between switches before connecting them physically. The links could be inter-fabric or intra-fabric links. Doing so, you can express and represent your intent to add links. The links with intent are displayed in a different color till they are actually converted to functional links. Once you physically connect the links, they are displayed as connected.

Management links might show up in the fabric topology as red colored links. To remove such links, right-click the link and click Delete Link.

The Border Spine and Border Gateway Spine roles are added to switch roles for border switches.

You can create links between existing and pre-provisioned devices as well by selecting the pre-provisioned device as the destination device.

Starting from Cisco NDFC Release 12.1.2e, parameters MTU, SPEED, Source Interface Description, Destination Interface Description, Source Interface Freeform Config, and Destination Interface Freeform Config are added to the existing int_pre_provision_intra_fabric_link template. These parameters are preserved on subsequent Recalculate & Deploy after the device has completed bootstrap and POAP.

The following table describes the fields that appear on Links tab.

Field Description

Fabric Name

Specifies the name of the Fabric.

Name

Specifies the name of the link.The list of previously created links is displayed. The list contains intra-fabric links, which are between switches within a fabric, and inter-fabric links, which are between border switches in this fabric and switches in other fabrics.

Policy

Specifies the link policy.

Info

Provides more information about the link.

Admin State

Displays the administrative state of the link.

Oper State

Displays the operational state of the link.

The following table describes the action items, in the Actions menu drop-down list, that appear on Fabric Overview > Links > Links.

Action Item Description

Create

Allows you to create the following links:

Edit

Allows you to edit the selected fabric.

Delete

Allows you to delete the selected fabric.

Import

You can import a CSV file containing details of links to add new links to the fabric. The CSV file should have the following details of links: link template, source fabric, destination fabric, source device, destination device, source switch name, destination switch name, source interface, destination interface, and nvPairs.

note.svg

You cannot update existing links.
The Import Links icon is disabled for external fabric.


Export

Select Actions > Export to export the links in a CSV file.

The following details of links are exported: link template, source fabric, destination fabric, source device, destination device, source switch name, destination switch name, source interface, destination interface, and nvPairs. The nvPairs field consists JSON object.

Click the Links tab. You can see a list of links. The list is empty when you are yet to create a link.

To create Intra-Fabric links, perform the following steps:

  1. From the Actions drop-down list, select Create.

    The Link Management - Create Link page appears.

  2. From the Link Type drop-down box, choose Intra-Fabric since you are creating an IFC. The screen changes correspondingly.

    The fields are:

    Link Type - Choose Intra-Fabric to create a link between two switches in a fabric.

    Link Sub-Type - This field populates Fabric indicating that this is a link within the fabric.

    Link Template: You can choose any of the following link templates.

    • int_intra_fabric_num_link: If the link is between two ethernet interfaces assigned with IP addresses, choose int_intra_fabric_num_link.

    • int_intra_fabric_unnum_link: If the link is between two IP unnumbered interfaces, choose int_intra_fabric_unnum_link.

    • int_intra_vpc_peer_keep_alive_link: If the link is a vPC peer keep-alive link, choose int_intra_vpc_peer_keep_alive_link.

    • int_pre_provision_intra_fabric_link: If the link is between two pre-provisioned devices, choose int_pre_provision_intra_fabric_link. After you click Save & Deploy, an IP address is picked from the underlay subnet IP pool.

      Correspondingly, the Link Profile section fields is updated.

      Source Fabric - The fabric name populates this field since the source fabric is known.

      Destination Fabric - Choose the destination fabric. For an intra-fabric link, source and destination fabrics are the same.

      Source Device and Source Interface - Choose the source device and interface.

      Destination Device and Destination Interface - Choose the destination device and interface.

      note.svg

      Select the pre-provisioned device as the destination device if you are creating a link between an existing device and a pre-provisioned device.


      General tab in the Link Profile section

      Interface VRF - Name of a non-default VRF for this interface.

      Source IP and Destination IP - Specify the source and destination IP addresses of the source and destination interfaces, respectively.

      note.svg

      The Source IP and Destination IP fields do not appear if you choose int_pre_provision_intra_fabric_link template.


      Interface Admin State - Check or uncheck the check box to enable or disable the admin sate of the interface.

      MTU - Specify the maximum transmission unit (MTU) through the two interfaces.

      Source Interface Description and Destination Interface Description - Describe the links for later use. For example, if the link is between a leaf switch and a route reflector device, you can enter the information in these fields (Link from leaf switch to RR 1 and Link from RR 1 to leaf switch). This description will converted into a config, but will not be pushed into the switch. After Save & Deploy, it will reflect in the running configuration.

      Disable BFD Echo on Source Interface and Disable BFD Echo on Destination Interface - Select the check box to disable BFD echo packets on source and destination interface.

      Note that the BFD echo fields are applicable only when you have enabled BFD in the fabric settings.

      Source Interface Freeform CLIs and Destination Interface Freeform CLIs: Enter the freeform configurations specific to the source and destination interfaces. You should add the configurations as displayed in the running configuration of the switch, without indentation. For more information, refer Enabling Freeform Configurations on Fabric Switches.

  3. Click Save at the bottom right part of the screen.

    You can see that the IFC is created and displayed in the list of links.

  4. On the Fabric Overview Actions drop-down list, select Recalculate Config.

    The Deploy Configuration screen comes up.

    It displays the configuration status on the switches. You can also view the pending configurations by clicking the respective link in the Pending Config column. It lists the pending configurations on the switch. The Side-by-side Comparison tab displays the running configuration and expected configuration side-by-side.

    Close the Pending Config screen.

  5. From Fabric Overview Actions drop-down list, select Deploy Config.

    The pending configurations are deployed.

    After ensuring that the progress is 100% in all the rows, click Close at the bottom part of the screen. The Links screen comes up again. In the fabric topology, you can see that the link between the two devices is displayed.

Click the Links tab. You can see a list of links. The list is empty when you are yet to create a link.

note.svg

In external fabrics, inter-fabric links support BGW, Border Leaf/Spine, and edge router switches. To create Inter-Fabric links, perform the following steps:


  1. From the Actions drop-down list, select Create.

    The Link Management - Create Link page appears.

  2. From the Link Type drop-down box, choose Inter-Fabric since you are creating an IFC. The screen changes correspondingly.

    The fields for inter-fabric link creation are as follows:

    Link Type - Choose Inter-Fabric to create an inter-fabric connection between two fabrics, over their border switches.

    Link Sub-Type - This field populates the IFC type. From the drop-down list, choose VRF_LITE, MULTISITE_UNDERLAY, or MULTISITE_OVERLAY.

    The Multi-Site options are explained in the Multi-Site use case.

    For information about VXLAN MPLS interconnection, see MPLS SR and LDP Handoff.

    For information about routed fabric interconnection, see Creating Inter-Fabric Links Between a Routed Fabric and an External Fabric section in Configuring a Fabric with eBGP Underlay chapter.

    Link Template - The link template is populated.

    The templates are autopopulated with corresponding prepackaged default templates that are based on your selection.

    note.svg

    You can add, edit, or delete user-defined templates. See Templates for more details.


    Source Fabric - This field is prepopulated with the source fabric name.

    Destination Fabric - Choose the destination fabric from this drop-down box.

    Source Device and Source Interface - Choose the source device and Ethernet interface that connects to the destination device.

    Destination Device and Destination Interface - Choose the destination device and Ethernet interface that connects to the source device.

    Based on the selection of the source device and source interface, the destination information is autopopulated based on Cisco Discovery Protocol information, if available. There is an extra validation that is performed to ensure that the destination external device is indeed part of the destination fabric.

    General tab in the Link Profile section.

    Local BGP AS# - In this field, the AS number of the source fabric is autopopulated.

    IP_MASK - Fill up this field with the IP address of the source interface that connects to the destination device.

    NEIGHBOR_IP - Fill up this field with the IP address of the destination interface.

    NEIGHBOR_ASN - In this field, the AS number of the destination device is autopopulated.

  3. Click Save at the bottom-right part of the screen.

    You can see that the IFC is created and displayed in the list of links.

  4. On the Fabric Overview Actions drop-down list, select Recalculate Config.

    The Deploy Configuration screen comes up.

    It displays the configuration status on the switches. You can also view the pending configurations by clicking the respective link in the Pending Config column. It lists the pending configurations on the switch. The Side-by-side Comparison tab displays the running configuration and expected configuration side by side.

    Close the Pending Config screen.

  5. From the Fabric Overview Actions drop-down list, select Deploy Config.

    The pending configurations are deployed.

    After ensuring that the progress is 100% in all the rows, click Close at the bottom part of the screen. The Links screen comes up again. In the fabric topology, you can see that the link between the two devices is displayed.

    If the two fabrics are member fabric of an MSD, then you can see the link in the MSD topology too.

What to do next:

If the two fabrics are member fabric of an MSD, then you can see the link in the MSD topology too.

When you enable the VRF Lite function using the ToExternalOnly method or Multisite function over MSD fabric, IFCs are automatically created between the (VXLAN fabric) border/BGW device and connected (external fabric) Edge router or Core device. When you remove the ER/core/border/BGW device, the corresponding IFCs (link PTIs) to/from that switch are deleted on Nexus Dashboard Fabric Controller. Next, Nexus Dashboard Fabric Controller removes the corresponding IFC configurations, if any, from the remaining devices on the next Save & Deploy operation. Also, if you want to remove a device that has an IFCs and overlay extensions over those IFCs, you should undeploy all overlay extensions corresponding to those IFCs for switch delete to be possible.

To undeploy VRF extensions, select the VXLAN fabric and the extended VRFs, and undeploy the VRFs in the VRF deployment screen.

To delete the IFCs, delete the IFCs from the Links tab.

Ensure that the fabric switch names are unique. If you deploy VRF extensions on switches with the same name, it leads to erroneous configuration.

The new fabric is created, the fabric switches are discovered in Nexus Dashboard Fabric Controller, the underlay networks that are provisioned on those switches, and the configurations between Nexus Dashboard Fabric Controller and the switches are synced. The remaining tasks are:

Protocol View

This tab displays the protocols for the links in the selected Fabric.

The following table describes the fields that appear on Protocol View tab.

Field Description

Fabric Name

Specifies the name of the fabric.

Name

Specifies the name of the link.

Is Present

Specifies if the link is present.

Link Type

Specifies the type of link.

Link State

Specifies the state of link.

UpTime

Specifies the time duration from when the link was up.

Policies

Cisco Nexus Dashboard Fabric Controller manages configuration of devices using Policies. Nexus Dashboard Fabric Controller policies are way of grouping all the required CLIs and variables to achieve certain configuration on the devices. These policies can be defined either using CLI commands or Python scripts. Nexus Dashboard Fabric Controller generates the configuration for a device based on the policies attached to the device.

With Release 12.1.3, Nexus Dashboard Fabric Controller provides the ability to create policy groups which can be applied to multiple switches. Policy groups let you create policies that define specific switch parameters that are common to switches and apply them to multiple switches in a fabric.

To access the Policies page:

  1. On the Cisco Nexus Dashboard Fabric Controller UI, choose LAN > Fabrics and double-click on a fabric.

    The Fabric Overview page opens.

  2. Go to the Policies tab

    The following table describes the fields that appear on the Fabric Overview > Policies page.

Field

Description

Template

Specifies the name of the policy template.

Description

Specifies the description, if available.

note.svg

From Cisco NDFC Release 12.1.1e, change of serial number for the switch is allowed, both old and new serial numbers can be viewed in this column.


Content Type

Specifies for the template content type. The supported content types are TEMPLATE_CLI, PYTHON and PYTHON_CLI.

Switch

Specifies the name of the switch the policy has been applied to.

If you are configuring a policy group, this field provides a link that specifies the number of switches that are linked to the policy. Click the link to open the policy group details dialog box with details such as the number of switches that are linked to the policy, the IP address, the fabric name, serial number, and mark deleted state.

Entity Name

Specifies the switch or the interface name to which the policy has been applied to.

Entity Type

Specifies if the entity is a switch or an interface.

Source

Specifies the source.

Priority

Specifies the priority.

During an Edit Membership operation to remove one or more switches from an existing policy group which uses Template_CLI content type, the Priority column displays the value Mixed indicating that the policy group has mixed priorities and mark deleted states.

Whereas, when you edit switch_freeform policies of Content Type PYTHON (where multiple CLI policy templates are combined with a common source), after an edit operation the system removes occurrence of the switch from the source policy and displays the source and the child policies as different entries. The Mark Deleted value for these switches in a child policy indicates the value true and the Priority indicates a negative value.

For a policy group, click on the link to view the group policy details of all the associated switches.

Editable

Specifies a Boolean value to indicate if the policy is editable.

Mark Deleted

Specifies a Boolean value to indicate if the policy is marked to be deleted. The column displays true indicating that the policy is marked for deletion. All the configurations for a policy with the Mark Deleted value true will be negated. The Generated Config for the policy displays the configuration to be removed from the switch.

For a policy group, click on the link to view the group policy details of all the associated switches.

Policy ID

Specifies the policy ID.

The policy ID for a policy group begins with the term POLICY-GROUP. While searching for a policy group, you can filter the policy ID using this term.

IP Address

Specifies the IP address of the switch.

If you are configuring a policy group, this field provides a link that specifies the IP addresses for the number of switches that are linked to the policy. Click on the link to view the group policy details of all the associated switches.

Serial Number

Specifies the serial number of the switch.

If you are configuring a policy group, this field provides a link that specifies the serial numbers for the switches that are linked to the policy. Click on the link to view the group policy details of all the associated switches.

The following table describes the action items, in the Actions menu drop-down list, that appear on LAN > Policies.

Action Item

Description

Add Policy

Allows you to create the following types of policies:

Edit Policy

To modify the policy, choose a policy from the table and choose Edit Policy.

note.svg

The policies in italics cannot be edited. The value under the Editable and Mark Deleted columns for these policies will indicate false.


You cannot perform Edit Policy for policies whose Mark Deleted value is set to true.

The switch freeform child policies of Mark Deleted policies appears in the Policies dialog box. You can edit only Python switch_freeform policies. You cannot edit Template_CLI switch_freeform_config policies.

Edit Membership

Lets you edit the membership configuration for a policy group. You can add or remove switches from a policy group using this option.

If you remove switches from a policy group, the Switch column in the policy details table still displays the original number of switches in the policy. However the Mark Deleted column in the details view dialog box displays true.

You cannot immediately edit a policy after an edit membership operation. The system displays an error message indicating to deploy the pending membership configuration changes to the switch before proceeding with any other configuration changes.

If you choose to not deploy the membership configuration changes and would like to edit the policy, ensure you perform Preview and proceed with the edit policy operation. Preview operation removes any pending configuration changes from the system.

You cannot perform Edit Membership for policies whose Mark Deleted value is set to true.

Delete Policy

To delete policies, choose the policies from the table and choose Delete Policy.

The following are the points to consider while deleting group policies:

  • For TEMPLATE_CLI policies, removing a policy group removes all the child policies from the switch.

  • For Python policies which has a source and multiple child policies, removing a policy group removes the source policy template instance (PTI) from the switch and displays only the child policies. The system shows the Generated Config as negative for both the child policies. You cannot delete the child polices without deploying the configuration. The child policies are deleted automatically after deploying all the pending configuration.

note.svg

A warning appears when you delete policies whose Mark Deleted values are set to true.


Deleting a TEMPLATE_CLI policy removes the policy directly from the switch and sets the Mark Deleted value to true. When you delete policies whose Mark Deleted values are set to true, these entries are only removed from the NDFC database; the configs are not deployed to the switch. These policies do not have any intent and hence you need not deploy the config to the switch.

Generated Config

To view the delta of configuration changes made by every user, select policies from the table and choose Generated Config.

Push Config

To apply the policy configuration to the device, select policies from the table and choose Push Config.

This option will be grayed out if the fabric is in freeze mode, that is, if you have disabled deployments on the fabric.

A warning appears if you apply configuration for a Python policy.

You cannot perform a Push Config for policies whose Mark Deleted value is set to true.

Adding a Policy

To add a policy, perform the following steps:

  1. Choose LAN > Fabrics. Double-click on the required fabric.

    The Fabric Overview window appears.

  2. On the Policies tab for a fabric, choose Actions > Add Policy.

    The Create Policy page appears.

  3. Select the required switch and click Next.

    You must deploy the switch in pending state.

  4. Click Choose Template and choose the appropriate policy template and click Select.

    From Cisco NDFC Release 12.1.2e, new templates ipv4_prefix_list and ipv6_prefix_list are added to the template list.

    From Cisco NDFC Release 12.1.2e, you can enable or disable PTP high-correction notification when the system encounters a high-correction event. Whenever the correction value exceeds the configured value then that correction is called a high-correction. By default, a high-correction notification is disabled. Enable it manually to generate the notification. Perform the following steps to enable the high-correction notification:

    1. Check the Enable PTP Telemetry check box to enable telemetry for PTP.

    2. Check the Is Large-Scale Fabric? check box to generate the high-correction notification.

      If there are more than 35 devices in a fabric, PTP events will be used if the switch version is 9.3(5) or higher, or else PTP correction data will be pushed periodically.

    3. Enter the wait time between two successive notifications in the PTP High-Correction Interval field.

      The duration value is in seconds.

    4. Set correction range threshold value (ns) in the PTP Correction Range field.

      The default is 100000 (100us).

  5. Enter the priority value for the policy in the Priority field.

    The applicable values are from 1 to 1000. The default value is 500. A lower number in the Priority field indicates that there is a higher priority for the generated configuration and POAP startup-configuration. For example, features are 50, route-maps are 100, and vpc-domain is 200.

  6. Depending on the policy template that you have selected, enter all the necessary field values to create a policy and click Save.

  7. If you have selected the ipv4_prefix_list or ipv6_prefix_list, perform the following steps to include the prefix-list entries:

    1. Enter the required name in the Prefix List Name field.

    2. On the Prefix-list Entries card, click ActionsAdd.

      The Add Item window appears.

    3. Configure the mandatory fields on the Add Item dialog box and click Save.

    4. Repeat the step to add the required number of prefix-list entries.

      note.svg

      The value in the Sequence Number must be higher than the previous prefix-list entry. If not, an error message is displayed.


    5. Select the appropriate prefix-list entry and click Actions > Insert Above to insert a new prefix-list entry.

      note.svg

      The value in the Sequence Number must be lower than the below prefix-list entry. If not, an error message is displayed.


Creating a Policy Group

Policy groups provides a method of configuring and managing switches collectively. This feature enables you to create group polices for switches that share common configurations. You can create a policy group and add multiple switches to the policy at the time of creating the policy group or later. Similarly, Policy groups also let you edit or delete policies for multiple switches simultaneously.

To create a policy, perform the following steps:

  1. Choose LAN > Fabrics and double-click on the required fabric.

    The Fabric Overview window appears.

  2. On the Policies tab for a fabric, choose Actions > Add Policy.

    The Create Policy page appears.

  3. To create a policy group, select the required switches to which you need to apply the policy and click Next.

    Ensure you select switches that are part of the same fabric.

  4. Enter the priority value for the policy in the Priority field.

    The applicable values are from 1 to 1000. The default value is 500. A lower number in the Priority field indicates that there is a higher priority for the generated configuration and POAP startup-configuration. For example, the priority for vPC related policies are as follows: base_feature_vpc is 100, vpc-domain_mgmt is 150, for policies for interfaces on vPC (int_vpc_peer_link_po) is 202.

  5. Use the toggle switch to enable or disable the Group option, as required.

    If you have selected multiple switches, the Group toggle switch is enabled by default. If you select one switch initially and choose to add additional switches later, you can select the Group toggle switch to create a policy group and add additional switches later.

    Not all templates provide support for creating policy groups. If you select a template that does not support policy group, the system generates an error message. Ensure you uncheck the Group toggle switch and create regular policies for templates that do not support policy group.

  6. Click Choose Template and choose the appropriate policy template and click Select.

    The available policy templates are TEMPLATE_CLI, PYTHON and PYTHON_CLI.

    Note that nested Python policies are not supported. Additionally, when configuring policy groups, make sure you do not add policies that can be applied only on a single switch. Select policies that can be applied on multiple switches.

  7. Depending on the policy template that you have selected, enter all the necessary field values to create a policy and click Save.

    The new policy group appears in the Fabric Overview > Policies page.

  8. To deploy the configuration to the switches, select the new policy that you have created and choose Actions > Push Config. Alternatively, to deploy the configuration, navigate to the Fabric Overview page, choose Actions > Deploy on the Switches tab.

    Note that Push Config option does not go through configuration compliance check. It should be used only when you want to deploy commands which are ignored during configuration compliance checks.

Advertising PIP on vPC

Choose required fabric on LAN Fabric window and Navigate to Edit Fabric > VPC, check the vPC advertise-pip check box to enable the Advertise PIP feature on all vPCs in a fabric. Choose the vpc_advertise_pip_jython policy to enable Advertise PIP feature on specific vPCs in a fabric.

Note the following guidelines:

  • If advertise-pip is not globally enabled or vPC peer is not using fabric peering, only then the vpc_advertise_pip_jython policy can be created on specific peers.

  • The policy vpc_advertise_pip_jython can be applied only when switches are part of vPC pairing.

  • Ensure that you configure vpc advertise-pip command during maintenance window as it involves BGP next-hop rewrite. Enabling this feature EVPN type 5 uses Switch Primary IP as next-hop while EVPN type 2 continue to use Secondary IP.

  • Disabling advertise pip for a fabric doesn’t affect this policy.

  • Unpairing of switches deletes this policy.

  • You can manually delete this policy from the peer switch where it was created.

To advertise PIP on vPC:

  1. Choose LAN > Fabrics. Double-click on the required fabric.

    The Fabric Overview window appears.

  2. On the Fabric Overview window, choose Policies > Add Policy and then select a switch with vPC.

  3. Click Actions > Add and choose the switch from the Switch List drop-down list. Choose vpc_advertise_pip_jython policy template and enter the mandatory parameters data.

    note.svg

    You can add this policy on one vPC peer, and it will create respective commands for vpc advertise on both peers.


  4. Click Save, and then deploy this policy.

Custom Maintenance Mode Profile Policy

When you place a switch in maintenance mode using NDFC, only a fixed set of BGP and OSPF isolate CLIs are configured in the maintenance mode profile. You can create a custom_maintenance_mode_profile PTI with customized configurations for maintenance mode and normal mode profile, deploy the PTI to the switch, and then move the switch to maintenance mode.

Creating and Deploying Custom Maintenance Mode Profile Policy

To create and deploy a custom maintenance mode profile policy from Web UI > Switches, perform the following procedure.

  1. Select the desired switch and launch Switch Overview.

  2. On the Policies tab, select Actions > Add Policy to add a new policy.

  3. On the Create Policy screen, click Choose Template.

  4. Select custom_maintenance_mode_profile from the Select Policy Template list.

  5. Fill in the Maintenance mode profile contents with the desired configuration CLIs.

    Example:

    configure maintenance profile maintenance-mode
    ip pim isolate

    Fill in the Normal mode profile contents with the desired configuration CLIs.

    Example:

    configure maintenance profile normal-mode
    no ip pim isolate
    configure terminal
  6. Click Save.

  7. From Switch Overview, click Actions > Preview.

  8. Click on Pending Config lines to view the Pending Config and Side-by-Side Comparison.

  9. Click Close.

  10. From Switch Overview, click Actions > Deploy. Click Deploy All to deploy the new policy configuration on the switch.

    Click Close after the deployment is complete.

  11. Select the policy and select Actions > More > Change Mode.

  12. In the Mode drop-down list, choose Maintenance.

  13. Click Save and Deploy Now to move the switch to maintenance mode.

Deleting Custom Maintenance Mode Profile Policy

The switch has to be moved to active/operational or normal mode before deleting the custom maintenance mode profile policy. To delete a custom maintenance mode profile policy from Web UI > Switches, perform the following procedure.

  1. Select the desired switch and launch Switch Overview.

  2. From Switch Overview > Actions > More > Change Mode.

  3. In the Mode drop-down list, choose Normal.

  4. Click Save and Deploy Now to move the switch to normal mode.

  5. After the switch has been moved to normal mode, select the custom_maintenance_mode_profile policy that has to be deleted.

  6. Choose Actions > Edit Policy.

  7. Choose Actions > Delete Policy and click Confirm to mark the Policy for deletion.

    The Mark Deleted column shows true indicating that the policy is marked for deletion.

  8. Again, choose Actions > Delete Policy and click Confirm to delete the Policy.

  9. From Switch Overview, click Actions > Deploy. Click Deploy All to delete the policy configuration on the switch.

    Click Close after the deployment is complete.

Event Analytics

Event Analytics includes the following topics:

Alarms

This tab displays the alarms that are generated for various categories. This tab displays information such as ID (optional), Severity, Failure Source, Name, Category, Acknowledged, Creation Time, Last Updated (optional), Policy, and Message. You can specify the Refresh Interval in this tab. You can select one or more alarms and then acknowledge or unacknowledge their status using the Change Status drop-down list. In addition, you can select one or more alarms and then click the Delete button to delete them.

Events

This tab displays the events that are generated for the switches. This tab displays information such as Ack, Acknowledged user, Group, Switch, Severity, Facility, Type, Count, Last Seen, and Description. You can select one or more events and then acknowledge or unacknowledge their status using the Change Status drop-down list. In addition, you can select one or more alarms and then click the Delete button to delete them. If you want to delete all events, click the Delete All button.

The following table describes the fields that appear on Operations > Event Analytics > Events.

Field Description

Group

Specifies the Fabric

Switch

Specifies the hostname of the switch

Severity

Specifies the severity of the event

Facility

Specifies the process that creates the events.The event facility includes two categories: NDFC and syslog facility. Nexus Dashboard Fabric Controller facility represents events generated by Nexus Dashboard Fabric Controller internal services and SNMP traps generated by switches. Syslog facility represents the machine process that created the syslog messages.

Type

Specifies how the switch/fabric are managed

Count

Specifies the number of times the event has occurred

Creation Time

Specifies the time when the event was created

Last Seen

Specifies the time when the event was run last

Description

Specifies the description provided for the event

Ack

Specifies if the event is acknowledged or not

The following table describes the action items, in the Actions menu drop-down list, that appear on Operations > Event Analytics > Events.

Action Item Description

Acknowledge

Select one or more events from the table and choose Acknowledge icon to acknowledge the event information for the fabric.After you acknowledge the event for a fabric, the acknowledge icon is displayed in the Ack column next to the Group.

Unacknowledge

Select one or more events from the table and choose Unacknowledge icon to acknowledge the event information for the fabric.

Delete

Select an event and choose *Delete*to delete the event.

Add Suppressor

Select an event and choose Add Suppressor to add a rule to the event. You can provide name to the rule. Using the Scope options, you can add this rule to all the Fabrics, or particular elements or all elements.

Event Setup

Allows you to setup new event. For more information, see the section "Setting Up Events" in Event Analytics: LAN.

Accounting

You can view the accounting information on Cisco Nexus Dashboard Fabric Controller Web UI.

The following table describes the fields that appear on Operations > Event Analytics > Accounting.

Field Description

Source

Specifies the source

User Name

Specifies the user name.

Time

Specifies the time when the event was created

Description

Displays the description.

Group

Specifies the name of the group.

The following table describes the action items, in the Actions menu drop-down list, that appear on Operations > Event Analytics > Accounting.

Action Item Description

Delete

Select a row and choose Delete to delete accounting information from the list.

Recent Tasks

UI Path: LAN > Fabric > Fabric Overview > Event Analytics > Recent Tasks

On Recent Tasks tab you can view the changes made for the event analytics.

note.svg

When the device is rebooted, the recent task details will be erased.


The following table describes the fields that appear on the Recent Tasks tab.

Field Description

Fabric

Specifies the name of the fabric.

Task Name

Specifies the name of operation done on fabric recently.

Task Description

Specifies the description of task done on fabric.

Duration

Specifies the time duration of the task.

Completed/Progress

Specifies the progress details, whether the task is completed 100% or still in progress.

VRFs

UI Navigation

The following options are applicable only for switch fabrics, easy fabrics, and MSD fabrics.

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > VRFs.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > VRFs.

note.svg

Overlay-mode CLI is available only for Easy and eBGP Vxlan Fabrics. To create overlay VRFs, create VRFs for the fabric and deploy them on the fabric switches. Before attaching or deploying the VRFs, set the overlay mode. For more information on how to choose the overlay mode, refer to Overlay Mode.


You can view the VRF details in the VRFs horizontal tab and VRF attachment details in the VRF Attachments horizontal tab.

This section contains the following:

VRFs

UI Navigation

The following options are applicable only for switch fabrics, easy fabrics, and MSD fabrics.

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > VRFs > VRFs.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > VRFs > VRFs.

Use this tab to create, edit, delete, import, and export VRFs. You can create networks only after creating VRFs except when you use Layer 2 to create networks.

Table 2. VRF Table Fields and Description
Field Description

VRF Name

Specifies the name of the VRF.

VRF Status

Specifies whether the status of the VRF deployment as NA, out-of-sync, pending, deployed, and so on.

VRF ID

Specifies the ID of the VRF.

Click the table header to sort the entries in alphabetical order of that parameter.

The following table describes the action items, in the Actions drop-down list, that appears on the VRFs horizontal tab of the VRFs tab in the Fabric Overview window.

Table 3. VRFs Actions and Description

Action Item

Description

Create

Allows you to create a new VRF. For more information, see Creating VRF.

Edit

Allows you to edit the selected VRF.

To edit a VRF, select the check box next to the VRF that you want to edit and choose Edit. In the Edit VRF window, you can edit the parameters and click Save to retain the changes or click Cancel to discard the changes.

Import

Allows you to import VRF information for the fabric.

To import VRF information, choose Import. Browse the directory and select the .csv file that contains the VRF information. Click Open. The VRF information is imported and displayed in the VRFs tab of the Fabric Overview window.

Export

Allows you to export VRF information to a .csv file. The exported file contains information pertaining to each VRF, including the configuration details that you saved during the creation of VRFs.

To export VRF information, choose Export. Select a location on your local system directory to store the VRF information from Nexus Dashboard Fabric Controller and click Save. The VRF information file is exported to your local directory. The file name is appended with the date and time at which the file was exported.

note.svg

You can use the exported .csv file for reference or use it as a template for creating new VRFs.


Delete

Allows you to delete a selected VRF.

To delete a VRF, select the check box next to the VRF that you want to delete and choose Delete. You can select multiple VRF entries and delete them at the same instance. A warning message appears asking whether you want to delete the VRF(s). Click Confirm to delete or click Cancel to retain the VRF. A message appears that the selected VRFs are deleted successfully.

Creating VRF

UI Navigation

The following options are applicable only for switch fabrics, Easy fabrics, and MSD fabrics.

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > VRFs > VRFs.

  • Choose LAN > Fabrics. Double-click on the fabric to open Fabric Overview > VRFs > VRFs.

To create VRF from the Cisco Nexus Dashboard Fabric Controller Web UI, perform the following steps:

  1. On the VRFs tab, click Actions > Create.

    The Create VRF window appears.

  2. On Create VRF, enter the required details in the mandatory fields. The available fields vary based on the fabric type.

    The fields in this window are:

    VRF Name - Specifies a VRF name automatically or allows you to enter a name. The VRF name should not contain any white spaces or special characters except underscore (_), hyphen (-), and colon (:).

    For MSD Fabrics, the values for VRF or Network is same for the fabric.

    VRF ID - Specifies the ID for the VRF or allows you to enter an ID for the VRF.

    VLAN ID - Specifies the corresponding tenant VLAN ID for the network or allows you to enter an ID for the VLAN. If you want to propose a new VLAN for the network, click Propose VLAN.

    VRF Template - A default universal template is auto-populated. This is applicable for leaf switches only.

    VRF Extension Template - A default universal extension template is auto-populated. This allows you to extend this network to another fabric. The methods are VRF Lite, Multi Site, and so on. The template is applicable for border leaf switches and BGWs.

  3. The fields on the General tab are:

    VRF VLAN Name - Enter the VLAN name for the VRF.

    VRF Interface Description - Enter a description for the VRF interface.

    VRF Description - Enter a description for the VRF.

  4. Click the Advanced tab to optionally specify the advanced profile settings. The fields on this tab are auto-populated. The fields on the Advanced tab are:

    VRF Interface MTU - Specifies VRF interface MTU.

    Loopback Routing Tag - If a VLAN is associated with multiple subnets, then this tag is associated with the IP prefix of each subnet. Note that this routing tag is associated with overlay network creation also.

    Redistribute Direct Route Map - Specifies the redistribute direct route map name.

    Max BGP Paths - Specifies the maximum number of BGP paths. The valid value is between 1 and 64.

    Max iBGP Paths - Specifies the maximum number of iBGP paths. The valid value is between 1 and 64.

    Enable IPv6 link-local Option - Select the check box to enable the IPv6 link-local option under the VRF SVI. If this check box is unchecked, IPv6 forward is enabled.

    TRM Enable - Check the check box to enable TRM.

    If you enable TRM, and provide the RP address, you must enter the underlay multicast address in the Underlay Mcast Address.

    NO RP - Check the check box to disable RP fields. You must enable TRM to edit this check box.

    If you enable NO RP, then the RP External, RP address, RP loopback ID, and Overlay Mcast Groups are disabled.

    Is RP External - Check this check box if the RP is external to the fabric. If this check box is not checked, RP is distributed in every VTEP.

    RP Address - Specifies the IP address of the RP.

    RP Loopback ID - Specifies the loopback ID of the RP, if Is RP External is not enabled.

    Underlay Multicast Address - Specifies the multicast address associated with the VRF. The multicast address is used for transporting multicast traffic in the fabric underlay.

    note.svg

    The multicast address in the Default MDT Address for TRM VRFs field in the fabric settings screen is auto-populated in this field. You can override this field if a different multicast group address should be used for this VRF.


    Overlay Multicast Groups - Specifies the multicast group subnet for the specified RP. The value is the group range in ip pim rp-address command. If the field is empty, 224.0.0.0/24 is used as default.

    Enable TRM BGW MSite - Check the check box to enable TRM on Border Gateway Multisite.

    Advertise Host Routes - Check this check box to control advertisement of /32 and /128 routes to Edge routers.

    Advertise Default Route - Check this check box to control advertisement of default route internally.

    To allow inter-subnet communication between end hosts in different VXLAN fabrics, where the subnets are present in both fabrics, you must disable the Advertise Default Route feature (clear the Advertise Default Route check box) for the associated VRF. This will result in /32 routes for hosts in both fabrics. For example, Host1 (VNI 30000, VRF 50001) in Fabric1 can send traffic to Host2 (VNI 30001, VRF 50001) in Fabric2 only if the host route is present in both fabrics. When a subnet is present in one fabric only then the default route is sufficient for inter-subnet communication.

    Config Static 0/0 Route - Check this check box to control configuration of static default route.

    BGP Neighbor Password - Specifies the VRF Lite BGP neighbor password.

    BGP Password Key Encryption Type - From the drop-down list, select the encryption type.

    Enable Netflow - Allows you to enable netflow monitoring on the VRF-Lite sub-interface. Note that this is supported only if netflow is enabled on the fabric.

    Netflow Monitor - Specifies the monitor for the VRF-lite netflow configuration.

    To enable netflow on a VRF-Lite sub-interface, you must enable netflow at VRF level and VRF extension level. Check the Enable_IFC_Netflow check box in the VRF attachment while you edit an extension to enable netflow monitoring.

    For more information, refer to Netflow Support.

  5. The fields on the Route Target tab are:

    Disable RT Auto-Generate - Check the check box to disable RT Auto-Generate for IPv4, IPv6 VPN/EVPN/MVPN.

    Import - Specifies comma separated list of VPN Route Target to import.

    Export - Specifies comma separated list of VPN Route Target to export.

    Import EVPN - Specifies comma separated list of EVPN Route Target to import.

    Export EVPN - Specifies comma separated list of EVPN Route Target to export.

    Import MVPN - Specifies comma separated list of MVPN Route Target to import.

    Export EVPN - Specifies comma separated list of MVPN Route Target to export.

    note.svg

    By default, Import MVPN and Export MVPN fields are disabled, check the TRM Enable check box on Advanced tab to enable these fields.


  6. Click Create to create the VRF or click Cancel to discard the VRF.

    A message appears indicating that the VRF is created.

    The new VRF appears on the VRFs horizontal tab. The status is NA as the VRF is created but not yet deployed.

note.svg

If you did not associate a VLAN with a VRF when you created the VRF using these instructions, you will see NA displayed in the VRF Overview for the VRF, even if a VLAN was associated with the VRF through another process (for example, if you disabled the Enable L3VNI w/o VLAN setting).


Now that the VRF is created, you can create and deploy networks on the devices in the fabric.

VRF Attachments

UI Navigation

The following options are applicable only for switch fabrics, VXLAN EVPN fabrics, and VXLAN EVPN Multi-Site fabrics.

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-out pane. Click the Launch icon. Choose Fabric Overview > VRFs > VRF Attachments.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > VRFs > VRF Attachments.

Use this window to attach or detach attachments to or from a VRF, respectively. You can also import or export the attachments for a VRF.

Table 4. VRF Attachments Table Fields and Description

Field

Description

VRF Name

Specifies the name of the VRF.

VRF ID

Specifies the ID of the VRF.

VLAN ID

Specifies the VLAN ID.

Switch

Specifies the name of the switch.

Status

Specifies the status of VRF attachments, for example, pending, NA, deployed, out-of-sync, and so on.

Attachment

Specifies whether the VRF attachment is attached or detached.

Switch Role

Specifies the switch role. For example, for the fabric created using the Campus VXLAN EVPN fabric template, the switch role is specified as either leaf, spine, or border.

Fabric Name

Specifies the name of the fabric to which the VRF is attached or detached.

Loopback ID

Specifies the loopback ID.

Loopback IPV4 Address

Specifies the loopback IPv4 address.

Loopback IPV6 Address

Specifies the loopback IPv6 address.

note.svg

The IPv6 address is not supported for underlay.


Click the table header to sort the entries in alphabetical order of that parameter.

The following table describes the action items, in the Actions drop-down list, that appears on the VRF Attachments horizontal tab of the VRFs tab in the Fabric Overview window.

Table 5. VRF Attachments Actions and Description
Action Item Description

History

Allows you to view the deployment and policy change history of the selected VRF.

You can view the deployment history details of a VRF attachment such as hostname, VRF name, commands, status, status description, user, and completed time on the Deployment History tab.

You can view the policy change history details such as policy ID, template, description, PTI operation, generated configuration, entity name and type, created date, serial number, user, and source of the policy on the Policy Change History tab.

To view the history of a VRF attachment, check the check box next to the VRF name and select History. The History window appears. Click the Deployment History*or *Policy Change History tabs as required. You can also click the Detailed History link in the Commands column of the Deployment History tab to view the command execution details (comprising configuration, status, and CLI response) for the host.

Edit

Allows you to view or edit the VRF attachment parameters such as interfaces that you want to attach to the selected VRF.

To edit the VRF attachment information, check the check box next to the VRF name that you want to edit. Select Edit. In the Edit VRF Attachment*window, edit the required values, attach or detach the VRF attachment. Click the *Edit link to edit the CLI freeform config for the switch, and click Save to apply the changes or click Cancel to discard the changes. The edited VRF attachment is shown in the table on the VRF Attachments horizontal tab of the VRFs tab in the Fabric Overview window.

Preview

Allows you to preview the configuration of the VRF attachments for the selected VRF.

note.svg

This action is not allowed for attachments that are in deployed or NA status.


To preview the VRF, check the check box next to the VRF name and choose Preview from Actions drop-down list. The Preview Configuration window for the fabric appears.

You can preview the VRF attachment details such as the VRF name, fabric name, switch name, serial number, IP address, and role, VRF status, pending configuration, and progress of the configuration. Click the lines link in the Pending Config column to view the lines for which the configuration is pending. Click Close.

Deploy

Allows you to deploy the pending configuration of the VRF attachments, for example, interfaces, for the selected VRF.

note.svg

This action is not allowed for attachments that are in deployed or NA status.


To deploy a VRF, check the check box next to the VRF name and choose Deploy from Actions drop-down list. The Deploy Configuration window for the fabric appears.You can view the details such as the VRF name, fabric name, switch name, serial number, IP address, and role, VRF status, pending configuration, and progress of the configuration. Click the lines link in the Pending Config column to view the lines for which the configuration is pending. Click the Deploy button. The status and progress of the deployment is displayed in the VRF Status and Progress columns. After the deployment is completed successfully, close the window.

Import

Allows you to import information about VRF attachments for the selected fabric.

To import the VRF attachments information, choose Import. Browse the directory and select the .csv file that contains the VRF attachments information. Click Open and then click OK. The VRF information is imported and displayed in the VRF Attachments horizontal tab on the VRFs tab in the Fabric Overview window.

Export

Allows you to export the information about VRF attachments to a .csv file. The exported file contains information pertaining to each VRF, including the fabric it belongs to, whether the LAN is attached, the associated VLAN, serial number, interfaces, and freeform configuration details that you saved for VRF attachments.

To export VRF attachments information, choose the Export action. Select a location on your local system directory to store the VRF information and click Save. The VRF information file is exported to your local directory. The file name is appended with the date and time at which the file was exported.

Quick Attach

Allows you to immediately attach an attachment to the selected VRF. You can select multiple entries and attach them to a VRF at the same instance.

To quickly attach any attachment to a VRF, choose Quick Attach from Actions drop-down list. A message appears to inform that the attach action was successful.

Quick Detach

Allows you to detach the selected VRF immediately from an attachment, for example, a fabric. You can select multiple entries and detach them from an attachment at the same instance.

To attach any attachment to a VRF quickly, choose Quick Detach from Actions drop-down list. A message appears to inform that the detach action was successful.

Networks

UI Navigation

The following options are applicable only for switch fabrics, easy fabrics, and MSD fabrics:

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Networks.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Networks.

note.svg

Before creating networks, ensure that you have created a VRF for the fabric. However, if you have chosen Layer 2, you do not require a VRF. For more information about VRFs, see VRFs.


To create overlay networks, create networks for the fabric and deploy them on the fabric switches. Before deploying the networks, set the overlay mode. For more information on how to choose the overlay mode, refer to Overlay Mode.

For information about creating interface groups and attaching networks, see the section "Interface Groups" in Add Interfaces: LAN.

You can view the network details in the Networks horizontal tab and network attachment details in the Network Attachments horizontal tab.

Networks

The following table describes the action items, in the Actions drop-down list, that appear on the Networks page.

Table 6. Networks Actions and Description

Action Item

Description

Create

Allows you to create a new network for the fabric. For instructions about creating a new network, see Creating Network for Standalone Fabrics.

Edit

Allows you to view or edit the selected network parameters.

  1. To edit the network information, check the check box next to the network name that you want to edit and choose Edit.

  2. On the Edit Network page, edit the required values and click Submit to apply the changes or click Cancel to discard the host alias.

    The edited network is shown in the table in the Networks tab of the Fabric Overview page.

Multi-Attach

Allows you to attach multiple switches and interfaces to the network at the same time.

  1. To attach the selected switches and interfaces to the network, select the check box next to the network name that you want to attach and choose Multi-Attach.

  2. On the Multi-Attach of Networks page, check the check boxes for the switches that you want to attach to the network and click Next.

  3. In the Select Interfaces area, check the check boxes for the interfaces that you want to attach to the network and click Next.

    The Summary page displays with the Proceed to Full Switch Deploy (Recommended) option selected.

  4. Click Save.

    The Deploy Configuration page appears with the selected switch.

  5. Click Deploy All.

    The Deploy Configuration page appears with an updated status of SUCCESS, Status Description, and Progress indicator.

  6. Click Close.

    The attached network displays as DEPLOYED in the Network Status column in the Networks tab of the Fabric Overview page.

Multi-Detach

Allows you to detach multiple switches from the network at the same time.

  1. To detach the selected switches from the network, select the check box next to the network name that you want to detach and choose Multi-Detach.

  2. On the Multi-Detach of Networks page, check the check boxes for the switches that you want to detach from the network and click Next.

    The Summary page displays with the Proceed to Full Switch Deploy (Recommended) option selected.

  3. Click Save.

    The Deploy Configuration page appears with the selected switch.

  4. Click Deploy All.

    The Deploy Configuration page appears with an updated status of SUCCESS, Status Description, and Progress indicator.

  5. Click Close.

    The detached network displays as NA (not attached) in the Network Status column in the Networks tab of the Fabric Overview page.

Deploy

Allows you to deploy the pending configuration for associating the switches or interfaces to the network.

  1. To deploy a network, check the check box next to the network name that you want to deploy and choose Deploy.

    The Deploy Configuration page for the fabric appears. You can view the details such as the network name, fabric name, switch name, serial number, IP address, and role, network status, pending configuration, and progress of the configuration.

  2. Click the Lines link in the Pending Config column to view the lines of the pending configuration.

    The Pending Config dialog box appears.

  3. Click Cancel after you have viewed the pending configuration.

  4. On the Deploy Configuration page, click the Deploy button.

    The status and progress of the deployment displays in the Network Status and the Progress columns.

  5. After the deployment completes successfully, close the page.

Import

Allows you to import network information for the fabric.

  1. To import network information, choose Import.

    The Import Networks dialog box appears.

  2. Browse to the directory with the .csv file that contains the host IP address and corresponding unique network information.

  3. Click OK.

    The host aliases are imported and displayed in the Networks tab of the Fabric Overview page.

Export

Allows you to export network information to a .csv file. The exported file contains information pertaining to each network, including the fabric it belongs to, the associated VRF, the network templates used to create the network, and all other configuration details that you saved during network creation.

  1. To export network information, choose Export.

    The network information file is exported to your local directory. The file name is appended with the date and time at which the file was exported.

    note.svg

    The Networks tab displays network names based on the number of rows per page. You can view network names based on the options in the Rows per page drop-down list. When you use the Export option, NDFC exports the network names as displayed per page. If you have a large number of network names and you want to export all of your network names, you need to navigate to each page and export each page individually.


  2. Before importing the file, update new records in the .csv file.

  3. Ensure that the networkTemplateConfig field contains the JSON Object.

Delete

Allows you to delete the network. You can select multiple network entries and delete them at the same time.

  1. To delete a network for the fabric, check the check box next to the network name that you want to delete and choose Delete.

    A Warning dialog box appears.

  2. Click Confirm to delete the network.

Add to Interface Group

Allows you to add the network to an interface group. You can select multiple network entries and add them to an interface group at the same time.

  1. To add the selected networks to the interface group that you want, check the check box for the network name you want and click Add to Interface Group.

  2. On the Add to Interface Group page, click the networks link and verify whether the selected networks are present on the Selected Networks page and then click Cancel.

  3. Either choose an interface group from the drop-down list or click Create Interface Group.

  4. On the Create Interface Group page, provide the interface group name, select the interface type, and then click Create to save the changes or click Close to discard the changes.

  5. On the Add to Interface Group page, click Save to save the changes or click Close to close the page and discard the changes.

    The interface group displays in the Interface Group column in the Networks tab of the Fabric Overview page.

Remove from Interface Group

Allows you to remove the network from an interface group. You can select multiple network entries and remove them from an interface group at the same time.

  1. To remove the selected networks to the interface group, check the checkbox for the network name for which you want to remove the interface group.

  2. Choose Remove from Interface Group.

  3. On the Remove from Interface Group page, click the networks link and verify whether the selected networks are present on the Selected Networks page and then click Cancel.

  4. On the Remove from Interface Group page, click Remove to remove the networks from the interface group and close the page or click Close to discard the changes.

    The interface group no longer displays in the Interface Group column in the Networks tab of the Fabric Overview page.

Table 7. Networks Table Fields and Description

Field

Description

Network Name

Specifies the name of the network.

Network ID

Specifies the Layer 2 VNI of the network.

VRF Name

Specifies the name of the Virtual Routing and Forwarding (VRF).

IPv4 Gateway/Prefix

Specifies the IPv4 address with a subnet.

IPv6 Gateway/Prefix

Specifies the IPv6 address with a subnet.

Network Status

Displays the status of the network.

VLAN ID

Specifies the VLAN id.

Interface Group

Specifies the interface group.

Creating Network for Standalone Fabrics

Before you begin:

Before creating networks, ensure that you have created a VRF for the fabric. However, if you have chosen Layer 2 on the Create Network window, then you do not require a VRF. For more information, see VRFs.

To create a network from the Cisco Nexus Dashboard Fabric Controller Web UI, perform the following steps:

  1. On the Networks tab, click Actions > Create.

    The Create Network window appears.

  2. On Create Network, enter the required details in the mandatory fields. The available fields vary based on the fabric type.

    The fields in this window are:

    Network ID and Network Name - Specifies the Layer 2 VNI and the name of the network. The network name should not contain any white spaces or special characters, except underscore (_) and hyphen (-). The corresponding Layer 3 VNI (or VRF VNI) is generated along with VRF creation.

    Layer 2 Only - Specifies whether the network is Layer 2 only.

    VRF Name - Allows you to select the Virtual Routing and Forwarding (VRF) from the drop-down list.

    If you want to create a new VRF, click Create VRF. The VRF name should not contain any white spaces or special characters except underscore (_), hyphen (-), and colon (:).

    VLAN ID - Specifies the corresponding tenant VLAN ID for the network. If you want to propose a new VLAN for the network, click Propose VLAN.

    Network Template - A default universal template is auto-populated. This is only applicable for leaf switches.

    Network Extension Template - A default universal extension template is auto-populated. This allows you to extend this network to another fabric. The methods are VRF Lite, Multi Site, and so on. The template is applicable for border leaf switches and BGWs.

    Generate Multicast IP - Click to generate a new multicast group address and override the default value.

  3. The fields on the General Parameters tab are:

    note.svg

    If the network is a non Layer 2 network, then it is mandatory to provide the gateway IP address.


    IPv4 Gateway/NetMask: Specifies the IPv4 address with subnet.

    Specify the anycast gateway IP address for transporting the L3 traffic from a server belonging to MyNetwork_30000 and a server from another virtual network. The anycast gateway IP address is the same for MyNetwork_30000 on all switches of the fabric that have the presence of the network.

    note.svg

    If the same IP address is configured in the IPv4 Gateway and IPv4 Secondary GW1 or GW2 fields of the network template, Nexus Dashboard Fabric Controller does not show an error, and you will be able to save this configuration.
    However, after the network configuration is pushed to the switch, it would result in a failure as the configuration is not allowed by the switch.


    IPv6 Gateway/Prefix List - Specifies the IPv6 address with subnet.

    Vlan Name - Enter the VLAN name.

    Interface Description - Specifies the description for the interface. This interface is a switch virtual interface (SVI).

    MTU for L3 interface - Enter the MTU for Layer 3 interfaces range 68 - 9216.

    IPv4 Secondary GW1 - Enter the gateway IP address for the additional subnet.

    IPv4 Secondary GW2 - Enter the gateway IP address for the additional subnet.

    IPv4 Secondary GW3 - Enter the gateway IP address for the additional subnet.

    IPv4 Secondary GW4 - Enter the gateway IP address for the additional subnet.

  4. Click the Advanced tab to optionally specify the advanced profile settings. The fields on the Advanced tab are:

    ARP Suppression - Select the check box to enable the ARP Suppression function.

    Ingress Replication - The check box is selected if the replication mode is Ingress replication.

    note.svg

    Ingress Replication is a read-only option in the Advanced tab. Changing the fabric setting updates the field.


    Multicast Group Address - The multicast IP address for the network is autopopulated.

    Multicast group address is a per fabric instance variable. The number of underlay multicast groups supported is 128. If all networks are deployed on all switches, you need not use a different multicast group per L2 VNI or a network. Therefore, multicast group for all networks in a fabric remains same.

    Starting from Cisco NDFC Release 12.1.2e, a maximum of 16 DHCP relay servers for overlay networks are supported. Perform the following steps to include the DHCP relay server information:

    1. On the DHCP Relay Server Information field, click Actions > Add.

      The ADD Item window appears.

    2. Enter the Server IP V4 Address and Server VRF details and click Save.

    3. Repeat the above steps to add the required number of DHCP relay server information.

      note.svg

      When you upgrade to NDFC Release 12.1.2e and newer, the existing DHCP server configurations in the network definitions using the shipping overlay templates will be automatically updated to the new structure without any configuration loss.


      DHCPv4 Server 3 - Enter the DHCP relay IP address of the next DHCP server.

      DHCPv4 Server3 VRF - Enter the DHCP server VRF ID.

      Loopback ID for DHCP Relay interface (Min:0, Max:1023) - Specifies the loopback ID for DHCP relay interface.

      Routing Tag - The routing tag is autopopulated. This tag is associated with each gateway IP address prefix.

      TRM enable - Check the check box to enable TRM.

      For more information, see Configuring Tenant Routed Multicast.

      L2 VNI Route-Target Both Enable - Check the check box to enable automatic importing and exporting of route targets for all L2 virtual networks.

      Enable Netflow - Enables netflow monitoring on the network. This is supported only if netflow is already enabled on fabric.

      Interface Vlan Netflow Monitor - Specifies the netflow monitor specified for Layer 3 record for the VLAN interface. This is applicable only if Is Layer 2 Record is not enabled in the Netflow Record for the fabric.

      Vlan Netflow Monitor - Specifies the monitor name defined in the fabric setting for Layer 3 Netflow Record.

      Enable L3 Gateway on Border - Check the check box to enable a Layer 3 gateway on the border switches.

  5. Click Create.

    A message appears indicating that the network is created.

    The new network appears on the Networks page that comes up.

    The Status is NA since the network is created but not yet deployed on the switches. Now that the network is created, you can create more networks if necessary and deploy the networks on the devices in the fabric.

Network Attachments

The following options are applicable only for switch fabrics, Easy fabrics, and MSD fabrics:

  • Choose LAN > Fabrics. Click on the fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Networks > Network Attachments.

  • Choose LAN > Fabrics. Double-click on the fabric to open Fabric Overview > Networks > Network Attachments.

Use this window to attach fabrics and interfaces to a network.

Table 8. Network Attachments Table Fields and Description

Field

Description

Network Name

Specifies the name of the network.

Network ID

Specifies the Layer 2 VNI of the network.

VLAN ID

Specifies the VLAN ID.

Switch

Specifies the name of the switch.

Ports

Specifies the ports for the interfaces.

Status

Specifies the status of the network attachments, for example, pending, NA, and so on.

Attachment

Specifies whether the network attachment is attached or detached.

Switch Role

Specifies the switch role. For example, for the fabric created using the Campus VXLAN EVPN fabric template, the switch role is specified as either leaf, spine, or border.

Fabric Name

Specifies the name of the fabric to which the network is attached or detached.

The following table describes the action items, in the Actions drop-down list, that appears in the Network Attachments horizontal tab on the Networks tab in the Fabric Overview window.

Table 9. Network Attachments Actions and Description

Action Item

Description

History

Allows you to view the deployment and policy change history of the selected network.

You can view the deployment history details of a network attachment such as hostname, network name, VRF name, commands, status, status description, user and completed time on the Deployment History tab.

You can view the policy change history details such as policy ID, template, description, PTI operation, generated configuration, entity name and type, created date, serial number, user, and source of the policy on the Policy Change History tab.

To view the history of a network attachment, select the check box next to the network name and choose the History action. The History window appears. Click the Deployment History or Policy Change History tabs as required. Click the Detailed History link in the Commands column of the Deployment History tab to view the command execution details (comprising configuration, status, and CLI response) for the host.

Edit

Allows you to view or edit the network attachment parameters such as interfaces that you want to attach to the selected network.

To edit the network attachment information, check the check box next to the network name that you want to edit and choose the Edit action. In the Edit Network Attachment window, edit the required values, attach or detach the network attachment, click the Edit link to edit the CLI freeform config for the switch, and click Save to apply the changes or click Cancel to discard the changes. The edited network attachment is shown in the table on the Network Attachments horizontal tab of the Networks tab in the Fabric Overview window.

Preview

Allows you to preview the configuration of the network attachments for the selected network.

note.svg

This action is not allowed for attachments that are in deployed or NA status.


To preview the network, check the check box next to the network name and choose Preview from Actions drop-down list. The Preview Configuration window for the fabric appears.

You can preview the network attachment details such as the network name, fabric name, switch name, serial number, IP address, and role, network status, pending configuration, and progress of the configuration. Click the lines link in the Pending Config column to view the lines for which the configuration is pending. Click Close.

Deploy

Allows you to deploy the pending configuration of the network attachments, for example, interfaces, for the selected network.

note.svg

This action is not allowed for attachments that are in deployed or NA status.


To deploy a network, check the check box next to the network name and choose Deploy from Actions drop-down list. The Deploy Configuration window for the fabric appears.

You can view the details such as the network name, fabric name, switch name, serial number, IP address, and role, network status, pending configuration, and progress of the configuration. Click the lines link in the Pending Config column to view the lines for which the configuration is pending. Click the Deploy button. The status and progress of the deployment is displayed in the Network Status and Progress columns. After the deployment is completed successfully, close the window.

Import

Allows you to import information about network attachments for the selected fabric.

To import the network attachments information, choose Import. Browse the directory and select the .csv file that contains the network attachments information. Click Open and then click OK. The network information is imported and displayed in the Network Attachments horizontal tab on the Networks tab in the Fabric Overview window.

Export

Allows you to export the information about network attachments to a .csv file. The exported file contains information pertaining to each network, including the fabric it belongs to, whether the LAN is attached, the associated VLAN, serial number, interfaces, and freeform configuration details that you saved for network attachments.

To export network attachments information, choose the Export action. Select a location on your local system directory to store the network information and click Save. The network information file is exported to your local directory. The file name is appended with the date and time at which the file was exported.

Quick Attach

Allows you to immediately attach an attachment to the selected network. You can select multiple entries and attach them to a network at the same instance.

note.svg

Interfaces cannot be attached to a network using this action.


To quickly attach any attachment to a network, choose Quick Attach from Actions drop-down list. A message appears to inform that the attach action was successful.

Quick Detach

Allows you to immediately detach the selected network from an attachment, for example, a fabric. You can select multiple entries and detach them from an attachment at the same instance.

To quickly detach any attachment to a network, choose Quick Detach from Actions drop-down list. A message appears to inform that the detach action was successful.

After quick detach, the switch status is not computed when there is no deploy. Post deploy, the configuration compliance calls at entity level (interface or overlay).

Private VLANs

Starting with Release 12.1.3, Cisco Nexus Dashboard Fabric Controller introduces support for Private VLAN (PVLAN) over VXLAN.

A Private Virtual Local Area Network (PVLAN) is a VLAN that isolates a Layer 2 port from the other ports in the same broadcast domain or subnet. PVLAN restricts Layer 2 traffic within a broadcast domain by segmenting the broadcast domain into multiple subdomains. A subdomain contains a PVLAN pair which includes a primary VLAN and one or more secondary VLANs. A PVLAN domain can have multiple PVLAN pairs, one for each subdomain. All VLAN pairs in a PVLAN domain share the same primary VLAN. A PVLAN domain can have only one primary VLAN.

Secondary VLANs provide Layer 2 isolation between ports within the same PVLAN. Although PVLANs provide host isolation at Layer 2, hosts can communicate with each other at Layer 3.

Guidelines and Limitations for Private VLANs over VXLAN

  • This feature is supported with Data Center VXLAN EVPN, BGP, VXLAN EVPN Multi-Site and External fabrics.

  • This feature is supported over physical interface, port-channel interface and virtual port channel (vPC) interfaces on the switches in a fabric.

  • This feature is supported on Layer 2 ToR interfaces.

  • This feature provides support for cli and config-profile overlay modes for VRF and network configuration.

  • This feature is supported only on VTEPs, and not supported on spine and super spine switches.

  • This feature is not supported on Brownfield deployments.

  • This feature is not supported on Interface groups on PVLAN interface.

Enabling PVLAN for a Fabric

  1. In Cisco Nexus Dashboard Fabric Controller, choose Lan > Fabrics.

  2. Choose Actions > Create Fabric and select the required template and click Select.

    To enable PVLAN on an existing fabric, select the fabric name and choose Actions > Edit Fabric.

  3. Go to the Advanced tab and check the Enable Private VLAN (PVLAN) checkbox.

    Ensure that you have checked the Enable EVPN VXLAN Overlay check box in the EVPN tab of the BGP fabric. You can enable the Enable Private VLAN (PVLAN) checkbox only if you have enabled VXLAN EVPN mode in your fabric.

  4. From the PVLAN Secondary Network Template list, select PVLAN template for the secondary network. The default is Pvlan_Secondary_Network.

  5. Click Save.

    A warning message appears prompting you to perform a Recalculate and Deploy.

  6. Click OK.

  7. Double-click the fabric to open the Fabric Overview window.

  8. Choose Actions > Recalculate and Deploy.

  9. Review the configurations after the Config Preview and click Deploy All.

    Performing a relcalculate and deploy enables feature private-vlan command on all the VTEPs and TORs.

    In an MSD fabric, if you add member fabrics that do not have PVLAN enabled, to an MSD with PVLAN enabled, the member fabrics inherit the feature automatically. However, if you haven’t enabled the PVLAN feature for the MSD, and try to add member fabrics with PVLAN enabled, the system generates an error.

note.svg

You cannot disable PVLAN feature in a fabric, if there are any PVLAN networks or PVLAN interface policies configured.


Configuring an Interface as a PVLAN Port

Before You Begin

Ensure that you have enabled PVLAN feature for the fabric.

Perform the following steps to configure a PVLAN port:

  1. In Cisco Nexus Dashboard Fabric Controller, choose Lan > Fabrics.

  2. Double-click the fabric name to open the Fabric Overview page.

  3. On the Interfaces tab, do one of the following:

    • For an Ethernet interface, select the required interface and choose Actions > Edit.

    • For a Port Channel or virtual Port Channel (vPC) interface, choose Actions > Create Interface.

  4. Under the Policy field, click the policy link to select the required PVLAN interface policy.

  5. In the Select Attached Policy Template dialog box, choose the required interface policy template and click Select.

    The following are the supported PVLAN interface policies:

    • int_pvlan_host: Specifies the interface template for creating a PVLAN port on an Ethernet interface.

    • int_port_channel_pvlan_host: Specifies the interface template for creating a PVLAN port-channel interface.

    • int_vpc_pvlan_host: Specifies the interface template for creating a vPC port for the PVLAN on a vPC pair.

      After attaching the PVLAN policy to an interface, the PVLAN tab appears.

  6. Configure all the necessary fields in the PVLAN tab.

    The fields in the PVLAN tab are described in the following table.

    Field Description

    PVLAN Mode

    Specifies the PVLAN port type. The following are the supported types:

    • promiscuous

    • trunk promiscuous

    • host

    • trunk secondary

    PVLAN Allowed Vlans

    Configures a list of allowed VLANs on a PVLAN trunk port.

    Native Vlan

    Configures a VLAN to transport the untagged packets on PVLAN trunk ports.

    If there is no native VLAN configured, all untagged packets are dropped.

    PVLAN Mapping

    Displays the mapping between the primary VLAN and the secondary VLANs. The fields in this area are enabled only if you select promiscuous or trunk promiscuous as the PVLAN mode.

    You can configure multiple VLAN pairs for the PVLAN. To add new primary-secondary VLAN pair, choose Actions > Add.

    PVLAN Association

    Configures the association between the primary VLAN and the associated secondary VLANs. The fields in this area are enabled only if you select host or trunk secondary as the PVLAN mode.

    You can configure multiple VLAN pairs for the PVLAN. To add a new primary-secondary VLAN pair, choose Actions > Add.

  7. When you have entered all the necessary information in the configuration fields, click Save.

    An error message appears if you have not enabled PVLAN for the fabric. See Enabling PVLAN for a Fabric for the steps to enable PVLAN for the fabric.

For external fabrics, Cisco Nexus Dashboard Fabric Controller provides support for PVLAN only at the interface level. Before configuring PVLAN interfaces, if feature private-vlan is not already enabled on the switch, ensure that you add a PVLAN policy for the switch using the feature-pvlan policy template. Perform a Recalculate and Deploy and then follow the steps mentioned in this section to create PVLAN interfaces.

Creating a Network for Primary and Secondary VLANs

  1. In Cisco Nexus Dashboard Fabric Controller, choose LAN > Fabrics.

  2. From the list of available fabrics, double-click the PVLAN-enabled fabric.

    The Fabric Overview page appears.

  3. Navigate to the Networks tab and choose Actions > Create.

    The Create Network window appears.

  4. Enter the required details in the following fields. Some of the fields are auto-populated with default values. You can make changes, as required.

    The fields in the Create Network window are:

    Field Description

    Network Type

    Click the Private (PVLAN) radio button.

    This radio button is available only if you have enabled private VLAN feature for the selected fabric.

    Private Network Type

    Specifies the VLAN type. Select one of the following options:

    • Primary - Select the option to configure your network as the primary VLAN. You can configure only one primary VLAN in a PVLAN.

    • Community - Select the option to configure a secondary VLAN to enable the hosts to communicate with each other as well as forward traffic to ports in the Primary VLAN.

    • Isolated - Select the option to configure an isolated secondary VLAN that enables the hosts to only forward traffic to the ports in the primary VLAN.

    Network Name

    Specifies the name of the network. The network name should not contain any white spaces or special characters except underscore (_) and hyphen (-).

    Layer 2 Only

    Enables you to create a Layer 2 only network.

    This field is applicable only for primary VLANs.

    Primary Network Name

    Choose the name of the primary network from the list of configured primary networks. This field is applicable only when you are configuring a secondary VLAN.

    VRF Name

    Allows you to select the VRF that you have created for the fabric.

    When no VRF is created, this field appears as blank. If you want to create a new VRF, click Create VRF. The VRF name should not contain any white spaces or special characters except underscore (_), hyphen (-), and colon (:).

    This field is applicable only for primary VLANs.

    Network ID

    Specifies the layer 2 Virtual Network Identifier (VNI) of the network.

    VLAN ID

    Specifies the corresponding tenant VLAN ID for the network. If you want to propose a new VLAN for the network, click Propose VLAN.

    Network Template

    Auto-populates the universal template for primary networks. For secondary networks, select the Pvlan_Secondary_Network template. This is only applicable for leaf switches.

    Network Extension Template

    Auto-populates the universal extension template for primary networks. For secondary networks, select the Pvlan_Secondary_Network template. This allows you to extend the network to another fabric. The VRF Lite extension is supported. The template is applicable for border leaf switches.

  5. When you have entered all the necessary information in the configuration fields, click Create.

    The table in the Networks tab displays all the newly created PVLAN networks.

What’s next: Once you have primary and secondary networks configured, you can attach the networks to the switches.

Attaching a Primary Network

After creating the primary and secondary networks, you can attach the networks to the switches and their PVLAN interfaces. You can attach a primary network either explicitly or implicitly.

  • Explicit Attach/Detach - Defines the method of manually attaching/detaching a network.

  • Implicit Attach/Detach - Defines the method in which a network is attached/detached automatically because one of the members in a PVLAN primary-secondary pair undergoes an explicit attachment/detachment.

This section is optional for VTEPs that only have PVLAN host or trunk secondary ports. If you want to perform an implicit attach for your primary network, you can skip the section and proceed to Attaching a Secondary Network.

Perform the following steps to attach a primary network explicitly.

  1. In Cisco Nexus Dashboard Fabric Controller, choose LAN > Fabrics.

  2. From the list of available fabrics, double-click the PVLAN-enabled fabric.

    The Fabric Overview page appears.

  3. Navigate to the Networks tab and double-click the primary network to open the Network Overview page.

  4. On the Network Attachments tab, select the required networks and choose Actions > Edit.

    The Edit Network Attachment page opens.

    The table under Available Interfaces for this device displays all the promiscuous ports and the promiscuous trunk ports available in the device. Note that for a primary PVLAN network, only the promiscuous ports and the promiscuous trunk ports are displayed.

    If you have ToR switches connected to the device, the pvlan interfaces on TOR switch will be displayed. If you select any TOR interface, the system adds PVLAN configuration to the TOR switch.

  5. Use the toggle button to enable Attach and then click Save.

  6. On the Networks tab, select the network and choose Actions > Deploy.

Attaching a Secondary Network

Perform the following steps to explicitly attach a secondary network.

  1. In Cisco Nexus Dashboard Fabric Controller, choose LAN > Fabrics.

  2. From the list of available fabrics, double-click the PVLAN-enabled fabric.

    The Fabric Overview page appears.

  3. Navigate to the Networks tab and double-click the secondary network to open the Network Overview page.

  4. On the Network Attachments tab, select the required networks and choose Actions > Edit.

    The Edit Network Attachment page opens.

    The table under Available Interfaces for this device displays all the ports of type host and trunk secondary. For a secondary PVLAN network, only the host ports and the trunk secondary ports are displayed. Both community and isolated PVLAN ports are labeled as PVLAN host ports. A PVLAN host port is either a community PVLAN port or an isolated PVLAN port depending on the type of secondary VLAN with which it is associated.

    If you have ToR switches connected to the device, the pvlan interfaces on TOR switch will be displayed. If you select any TOR interface, the system adds PVLAN configuration to the TOR switch.

    Note that you cannot attach an interface group to a secondary network.

  5. Use the toggle button to enable Attach, and then click Save.

    If you have not already performed an Attach for your primary network, the system automatically attaches the primary network along with the secondary network. You can view the network status for both the primary and the secondary networks in the Networks tab of the Fabric Overview window.

    When a secondary network is attached to a switch, it implicitly attaches to the other switches where its primary network is in explicit attach state, if the secondary network is not already attached.

  6. On the Networks tab, select the network and choose Actions > Deploy.

Explicit and Implicit Detach

The steps to detach a network are similar to the steps for attaching a network. The following points describes how implicit and explicit detach feature works.

  • When you detach a primary network in explicit state, the following occurs:

    • If there is no secondary network in explicit state on the switch, the primary network is detached along with all the associated secondary networks

    • If there is any secondary network in explicit state, the primary network does not detach but changes to implicit state

  • When you detach a secondary network explicitly, the primary network detaches automatically (implicitly) if the following conditions are met:

    • If the primary network is in implicit attached state

    • If the detached secondary is the only secondary network for this primary network on this switch

    • If no other switch in the fabric has this secondary in explicit attach state, this secondary network also gets detached from the other switches

History

The history tab displays information about the deployment and policy change history. Choose LAN > Fabrics. Double-click a fabric name to open the Fabric Overview window and then click the History tab.

Viewing Deployment History

Deployment HistoryDeployment history of the switches and networks that are involved in the selected service policy or route peering are displayed in the Deployment History tab. The deployment history captures the changes that are pushed or deployed from Nexus Dashboard Fabric Controller to switches. The deployment history captures the changes that are pushed or deployed from Nexus Dashboard Fabric Controller to switches.

The following table describes the fields that appear on this page.

Field

Description

Hostname (Serial Number)

Specifies the host name.

Entity Name

Specifies the entity name.

Entity Type

Specifies the entity type.

Source

Specifies the source.

Commands

Specifies the commands.

Status

Specifies the status of the host.

Status Description

Specifies the status description.

User

Specifies the user.

Time of Completion

Specifies the timestamp of the deployment.

note.svg

In certain scenarios after deploying configurations on a switch, the Status column displays the following error indicating a failure. However, the Config Status in LAN > Switches page displays In-Sync. The reason for a conflicting status is due to inter-node connectivity issue that causes the keep alives between the sim-agent and the sim-master to fail resulting in an agent expiry event. Whereas the sim-agent is alive and deploying the configuration on the switch. This does not require any further action.

Deployment Failed to execute job for this device with "Reason: dcnm-sim-agent-xx expired.

Viewing Policy Change History

Policy Change HistoryDifferent users can simultaneously change expected configuration of switches in the Nexus Dashboard Fabric Controller. You can view the history of policy changes in the Policy Change History tab.

The following table describes the fields that appear on this page.

Field

Description

Policy ID

Specifies the policy ID.

Template

Specifies the template that is used.

Description

Specifies the description.

PTI Operation

Specifies the Policy Template Instances (PTIs).

Generated Config

Specifies the configuration history. Click Detailed History to view the configuration history.

Entity Name

Specifies the entity name.

Entity Type

Specifies the entity type.

Created On

Specifies that date on which the policy was created.

Priority

Specifies the priority value.

Serial Number

Specifies the serial number.

Content Type

Specifies the content type.

User

Specifies the user.

Source

Specifies the source.

Resources

Resources Cisco Nexus Dashboard Fabric Controller allows you to manage the resources. The following table describes the fields that appear on this page.

Field

Description

Scope Type

Specifies the scope level at which the resources are managed. The scope types can be Fabric, Device, Device Interface, Device Pair, and Link.

Scope

Specifies the resource usage scope. Valid values are the switch serial numbers or fabric names. Resources with serial numbers are unique and can be used on the serial number of the switch only.

Device Name

Specifies the name of the device.

Device IP

Specifies the IP address of the device.

Allocated Resource

Specifies if the resources are managed with device, device interface, or fabric. Valid values are ID type, subnet, or IP addresses.

Allocated To

Specifies the entity name for which the resource is allocated.

Resource Type

Specifies the resource type. The valid values are TOP_DOWN_VRF_LAN, TOP_DOWN_NETWORK_VLAN, LOOPBACK_ID, VPC_ID, and so on.

Is Allocated?

Specifies if the resource is allocated or not. The value is set to True if the resource is permanently allocated to the given entity. The value is set to False if the resource is reserved for an entity and not permanently allocated.

Allocated On

Specifies the date and time of the resource allocation.

ID

Specifies the ID.

Allocating a Resource

To allocate a resource from the Cisco Nexus Dashboard Fabric Controller Web UI, perform the following steps:

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Resources tab.

  4. Click Actions > Allocate Resource to allocate the resource.

    The Allocate Resource window appears.

  5. Choose the pool type, pool name, and scope type from the drop-down lists accordingly.

    The options for pool type are ID_POOL, SUBNET_POOL, and IP_POOL. Based on the pool type you choose, the values in the Pool Name drop-down list changes.

  6. Enter the entity name in the Entity Name field.

    The embedded help gives example names for different scope types.

  7. Enter the ID, IP address, or the subnet in the Resource field based on what pool type you chose in Step 3.

  8. Click Save to allocate the resource.

Examples to Allocate Resources

Example 1: Assigning an IP to loopback 0 and loopback 1

#loopback 0 and 1
    L0_1: #BL-3
        pool_type: IP
        pool_name: LOOPBACK0_IP_POOL
        scope_type: Device Interface
        serial_number: BL-3(FDO2045073G)
        entity_name: FDO2045073G~loopback0
        resource : 10.7.0.1


    # L1_1: #BL-3
    #     pool_type: IP
    #     pool_name: LOOPBACK1_IP_POOL
    #     scope_type: Device Interface
    #     serial_number: BL-3(FDO2045073G)
    #     entity_name: FDO2045073G~loopback1
    #     resource : 10.8.0.3

Example 2: Assigning a Subnet

#Link subnet
    Link0_1:
        pool_type: SUBNET
        pool_name: SUBNET
        scope_type: Link
        serial_number: F3-LEAF(FDO21440AS4)
        entity_name: FDO21440AS4~Ethernet1/1~FDO21510YPL~Ethernet1/3
        resource : 10.9.0.0/30

Example 3: Assigning an IP to an Interface

    #Interface IP
    INT1_1: #BL-3
        pool_type: IP
        pool_name: 10.9.0.8/30
        scope_type: Device Interface
        serial_number: BL-3(FDO2045073G)
        entity_name: FDO2045073G~Ethernet1/17
        resource : 10.9.0.9

Example 4: Assigning an Anycast IP

    #ANY CAST IP
    ANYCAST_IP:
        pool_type: IP
        pool_name: ANYCAST_RP_IP_POOL
        scope_type: Fabric
        entity_name: ANYCAST_RP
        resource : 10.253.253.1

Example 5: Assigning a Loopback ID

    #LOOPBACK ID
    LID0_1: #BL-3
        pool_type: ID
        pool_name: LOOPBACK_ID
        scope_type: Device
        serial_number: BL-3(FDO2045073G)
        entity_name: loopback0
        resource : 0

Releasing a Resource

To release a resource from the Cisco Nexus Dashboard Fabric Controller Web UI, perform the following steps:

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Resources tab.

  4. Choose a resource that you want to delete.

    note.svg

    You can delete multiple resources at the same time by choosing multiple resources.


  5. Click Actions > Release Resource(s) to release the resource.

    A confirmation dialog box appears.

  6. Click Confirm to release the resource.

Hosts

note.svg

This tab is only available on IPFM fabric when you have deployed IPFM on Nexus Dashboard Fabric Controller.


  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts.

Information about hosts is also displayed as a card on the Overview tab in the Fabric Overview window. For more information about these cards, see Overview.

The Hosts tab includes the following tabs:

Discovered Hosts Summary

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Discovered Hosts Summary.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Discovered Hosts Summary.

You can view a summary of all the hosts that are populated through telemetry in this window.

Table 10. Discovered Hosts Summary Table Fields and Description

Field

Description

VRF

Specifies the VRF for the host.

Host

Specifies the IP address for the host.

Senders/Receivers

Specifies the number of times the host device plays its role as a sender or a receiver. Click the count to view where it was used.

Click the table header to sort the entries in alphabetical order of that parameter.

Discovered Hosts

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Discovered Hosts.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Discovered Hosts.

You can view all the hosts that are populated through telemetry on this screen. After the switches are discovered, all the switches in the fabric will push data to the Nexus Dashboard Fabric Controller server at regular intervals using telemetry. Cisco Nexus Dashboard Fabric Controller server displays the received Events and Flow statistics for each active flow.

Table 11. Discovered Hosts Table Fields and Description

Field

Description

VRF

Specifies the VRF for the host.

Host

Specifies the IP address for the host.

Role

Specifies the role of the host device. The role of the host can be one of the following:

  • Sender

  • External Sender

  • Dynamic Receiver

  • External Receiver

  • Static Receiver

Multicast Group

Specifies the multicast address of the flow in which the host participates.

Source

Specifies the source of the flow which the discovered host participates in.

Switch

Specifies the name of the switch.

Interface

Specifies the interface to which the host is connected to on the sender or receiver switch.

MAC Address

Specifies the MAC address of a physical host, if the switch has ARP entry for that host).

Host Discovered Time

Specifies the date and time at which the switch discovered the host.

Fault Reason

Specifies the failure reason for the flow that the discovered host has participates in.

Click the table header to sort the entries in alphabetical order of that parameter.

Host Policies

  • Choose LAN > Fabrics. Click on a fabric name to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Host Policies.

  • Choose LAN > Fabrics. Double-click on a fabric name to open Fabric Overview > Hosts > Host Policies.

You can add policies to the host devices. Navigate to Host Policies to configure the host policies.

note.svg

Switches must be deployed with default host policies. You can edit the default host policies to permit or deny. From the Deployment drop-down list, select Deploy Selected Policies to deploy the default policies to the switches. You can also deploy all the default policies to all the managed switches by selecting Deploy All Default Policies even without selecting any default policies.


By default, the sequence numbers for policies are auto-generated by Nexus Dashboard Fabric Controller and Multicast mask/prefix is taken as /32. If you want to enter the required values for the sequence number and the multicast mask/prefix in the appropriate fields, ensure that the Enable mask/prefix for the multicast range in Host Policy check box under Settings > Server Settings > IPFM tab is enabled. Then, you can enter the sequence number and the multicast mask/prefix in the appropriate fields available in the Create Host Policy and Edit Host Policy options available in the Actions drop-down list in the Host Policies window.

The default host policies must be deployed successfully to the switch before you deploy the custom host policies on that switch. Otherwise, the custom policies will fail to deploy. Ensure that you deploy all default policies successfully to all the switches before you create, edit, import, or deploy custom policies.

note.svg

When a user logs in to Nexus Dashboard Fabric Controller with a network operator role, all the buttons or options to create, delete, edit, import, export, or deploy policies are disabled. This user can only view policies, and deployment status or history.


Policies are automatically deployed to switches whenever they are created, edited, or imported. You can choose to undeploy or redeploy the policies, by selecting one or more check boxes next to the policies and choosing the appropriate actions in the Actions drop-down list. The policies will not be deployed correctly if the device is rebooting while the policy was deployed. In such case, the Failed message appears in the Deployment Status column in the Host Policies window.

note.svg

If you have created a custom or non-default VRF, although the host and flow policies are automatically created for the VRF, use the action options in this window to manually deploy the host policies to the switches in the fabric.


The following table describes the action items, in the Actions drop-down list, that appears in the Host Policies window.

Table 12. Host Policies Actions and Description

Action Item

Description

Create Host Policy

Allows you to create a new host policy. For instructions about creating a host policy, see Create Host Policy.

Edit Host Policy

Allows you to view or edit the selected host policy parameters.

To edit the host policy, select the check box next to the host policy that you want to delete and choose Edit Host Policy. In the Edit Host Policy*window, edit the required values and click *Save & Deploy to configure and deploy the policy or click Cancel to discard the host policy. The edited host policy is shown in the table in the Host Policies window.

note.svg

The changes made to host policy are applied immediately. If the policy is already applied to any device, the changes may impact the existing flows.


Delete Host Policy

Allows you to delete user-defined host policies.

note.svg

Undeploy policies from all the switches before deleting them from Nexus Dashboard Fabric Controller.
Default policy can be undeployed from the switches on which it is deployed. However, Custom policy can be deleted and undeployed.
When you undeploy the default policies, all default policies are reset to have default permission (Allow).


To delete a host policy, select the check box next to the host policy that you want to delete and choose Delete Host Policy. You can select multiple host policy entries and delete them at the same instance.

A delete host policy successful message appears at the bottom of the page.

Purge

Allows you to delete all custom policies without selecting any policy check box.NOTE:
* Undeploy policies from all switches before deleting them from Nexus Dashboard Fabric Controller.
* You can undeploy the default policy, but you cannot delete the default policy. You can delete and undeploy only the custom policies.

Import

Allows you to import host policies from a CSV file to Nexus Dashboard Fabric Controller.

note.svg

After import, all policies imported from a CSV file are applied to all managed switches automatically.


To import a host policies, choose Import. Browse the directory and select the .csv file that contains the host policy configuration information. The policy will not be imported if the format in the .csv file is incorrect. Click Open. The imported policies are automatically deployed to all the switches in the fabric.

Export

Allows you to export host policies from Nexus Dashboard Fabric Controller to a .csv file.

To export host policies, choose Export. Select a location on your local system directory to store the host policy details file. Click Save. The host policy file is exported to your local directory. The filename is appended with the date on which the file is exported. The format of the exported file is .csv.

Deploy Selected Policies

Select this option to deploy only the selected policies to the switch.

Deploy All Custom Policies

Select this option to deploy all the custom or user-defined policies to the switch in a single instance. If the policies are deployed when the switch is rebooting, the deployment fails and a failed status message appears.

Deploy All Default Policies

Select this option to deploy all default policies to the switch.

Undeploy Selected Policies

Select this option to undeploy the selected policies.Select one or more check boxes next to the policy name. Select this option from the drop-down list to undeploy the selected policies.

Undeploy All Custom Policies

Select this option to undeploy all the custom or user-defined policies in a single instance.

Undeploy All Default Policies

Select this option to undeploy the default policies.

Redo All Failed Policies

The deployment of policies may fail due to various reasons. Select this option to deploy or undeploy all failed policies.All the deployments that failed on switches previously will be deployed again to only those switches. All the undeployments that failed on switches previously will be undeployed again from only those switches.

Deployment History

Select one policy from the drop-down list. Select this option to view the deployment history of the selected policy in the Deployment History pane.

The policy name is shown in the Policy Name field. From the drop-down list, choose the switch on which this policy was deployed.

The Deployment History pane displays the following fields.

  • Policy Name - Specifies the selected policy name.

  • VRF - Specifies the VRF for the selected policy.

  • Switch Name - Specifies the name of the switch that the policy was deployed to.

  • Deployment Status - Displays the status of deployment. It shows if the deployment was a success, failed, or not deployed. Click on the deployment status, for example, Success, to see more details. For more information about the deployment status, see !!!Dita2Adoc_MissingReference:!!!.

  • Action - Specifies the action that is performed on the switch for that host policy. Create implies that the policy has been deployed on the switch. Delete implies that the policy has been undeployed from the switch.

  • Deployment Date/Time - Specifies the date and time at which the host policy was last updated. The format is Day MMM DD YYYY HH:MM:SS Timezone.

  • Failed Reason - Specifies why the policy was not successfully deployed.

Table 13. Host Policies Table Field and Description

Field

Description

VRF

Specifies the VRF for the host. The fields─Deployment, Undeployment, Status, and History─are based on VRF.

Policy Name

Specifies the policy name for the host, as defined by the user.

Receiver

Specifies the IP address of the receiving device.

Multicast IP/Mask

Specifies the multicast IP address for the host.

Sender

Specifies the IP Address of the transmitting device.

Host Role

Specifies the host device role. The host device role is either one of the following:

  • Sender

  • Receiver

  • Receiver-External

  • Receiver-Local

Operation

Specifies if the operation of the host policy. The policy has the following operations: * Permit * Deny

Sequence Number

Specifies the sequence number of the custom policy when the multicast range is selected.

Deployment Action

Specifies the action performed on the switch for that host policy.

  • Create - The policy is deployed on the switch.

  • Delete - The policy is undeployed from the switch.

Deployment Status

Specifies if the deployment is successful, failed, or the policy is not deployed.

Last Updated

Specifies the date and time at which the host policy was last updated. The format is Day MMM DD YYYY HH:MM:SS Timezone.

Deployment Status

The following table describes the fields that appear on the Deployment Status.

Table 14. Deployment Status Field and Description

Field

Description

Policy Name

Specifies the name of the host policy.

VRF

Specifies the name of the VRF.

Switch Name

Specifies the switch on which the VRF is deployed.

IP Address

Specifies the IP address of the switch.

Deployment Status

Displays the status of the deployment. It shows if the deployment was a Success or Failed along with the reason why the deployment failed.

Action

Specifies the action that is performed on the switch, for example, Create.

Deployment Date/Time

Displays the date and time when the deployment was initialized.

This section contains the following:

Create Host Policy

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Host Policies.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Host Policies.

The default host policies must be deployed successfully to the switch before you deploy the custom host policies on that switch. Otherwise, the custom policies will fail to deploy. Ensure that you deploy all default policies successfully to all the switches before you add custom policies.

To create a host policy from the Cisco Nexus Dashboard Fabric Controller, perform the following steps:

  1. In the Host Policies window, from the Actions drop-down list, choose Create Host Policy.

  2. In the Create Host Policy window, specify the parameters in the following fields.

    • VRF - Click the Select a VRF link to open the Select a VRF window. The default VRF is also listed in the window. Search and select a VRF for the host and click Save.

      note.svg

      Policy names can be repeated across VRFs, that is, they are unique only within a VRF.
      Across the VRF, host policies may be same or different.


    • Policy Name - Specifies a unique policy name for the host policy.

    • Host Role - Specifies the host as a multicast sender or receiver. Select one of the following:

      • Sender

      • Receiver-Local

      • Receiver-External

    • Sender Host Name - Specifies the sender host to which the policy is applied.

      note.svg

      Hosts that are discovered as remote senders can be used for creating sender host policies.


    • Sender IP - Specifies the IP address of the Sender host. Note that you can specify wildcard for this IP address by specifying the * (asterisk) symbol or 0.0.0.0 in this field.

    • Receiver Host Name - Specifies the receiver host to which the policy is applied. If a destination host is detected, you can choose the hostname from the drop-down list.

      note.svg

      Do not select hosts that are discovered as remote receivers to create receiver or sender host policies. However, hosts that are discovered as remote senders can be used for creating sender host policies.


    • Receiver IP - Specifies the IP address of the receiver host. This field is visible and is applicable only if the Host Role is set to Receiver-Local. Note that you can specify wildcard for this IP address by specifying the * (asterisk) symbol or 0.0.0.0 in this field.

      note.svg

      When Receiver IP in a receiver host policy is a wildcard (* or 0.0.0.0), Sender IP also has to be a wildcard (* or 0.0.0.0).


    • Multicast - Specifies the multicast IP Address for the host policy. Note that you can specify wildcard for this IP address by specifying the * (asterisk) symbol in this field. This will translate to 224.0.0.0/4. If you specify a wildcard IP address for Sender IP and Receiver IP fields, the Multicast Group is always required, that is, you cannot specify multicast as * or 0.0.0.0.

    • Permit/Deny - Click Permit if the policy must allow the traffic flow. Click Deny if the policy must not allow the traffic flow.

  3. Click Save & Deploy to configure and deploy the Policy. Click Cancel to discard the new policy. The deployment completed message appears at the bottom of the window. You can click Refresh to refresh the current deployment status in the window or click View Details to verify the deployment details.

Host Alias

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Host Alias.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Host Alias.

note.svg

This section is applicable for both the IPFM and Generic Multicast modes in Nexus Dashboard Fabric Controller.


Cisco Nexus Dashboard Fabric Controller allows you to create host aliases for sender and receiver hosts for IPFM fabrics. The active multicast traffic transmitting and receiving devices are termed as hosts. You can add a host-alias name to your sender and receiver hosts, to help you identify the hosts by a name. You can also import many Host Alias to Cisco Nexus Dashboard Fabric Controller with IPFM deployment.

The following table describes the action items, in the Actions drop-down list, that appears in the Host Alias window.

Table 15. Host Alias Actions and Description

Action Item

Description

Create Host Alias

Allows you to create a new host alias. For instructions about creating a new host alias, see Create Host Alias.

Edit Host Alias

Allows you to view or edit the selected host alias parameters.

To edit the host alias, select the check box next to the host alias that you want to delete and choose Edit Host Alias. In the Edit Host Alias window, edit the required values and click Submit to apply the changes or click Cancel to discard the host alias. The edited host alias is shown in the table in the Host Alias window.

Delete Host Alias

Allows you to delete the host alias.

To delete a host alias, select the check box next to the host alias that you want to delete and choose Delete Host Alias. You can select multiple host alias entries and delete them at the same instance.

Import

Allows you to import host aliases for devices in the fabric.

To import host aliases, choose Import. Browse the directory and select the .csv file that contains the host IP address and corresponding unique host name information. Click Open. The host aliases are imported and displayed in the *Host Alias*window.

Export

Allows you to export host aliases for devices in the fabric.

To export a host alias, choose Export. Select a location on your local system directory to store the host aliases configuration from Nexus Dashboard Fabric Controller and click Save. The host alias configuration file is exported to your local directory. The file name is appended with the date and time at which the file was exported. The format of the exported file is .csv.

Table 16. Host Alias Table Field and Description

Field

Description

VRF

Specifies the VRF for the host.

Host Alias

Specifies the host name that is configured to identify the host.

IP Address

Specifies the IP address of the host connecting to the switch, which you want to refer with an alias name.

Last Updated At

Specifies the date and time at which the host alias was last updated.

This section contains the following:

Create Host Alias

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Host Alias.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Host Alias.

Perform the following task to create new host aliases to devices in the fabric discovered by Cisco Nexus Dashboard Fabric Controller.

To create a host alias from the Cisco Nexus Dashboard Fabric Controller, perform the following steps:

  1. In the Host Alias window, from the Actions drop-down list, choose Create Host Alias.

  2. In the *Create Host Alias*window, enter the following:

    note.svg

    All the fields are mandatory.


    • VRF - Select the VRF from this drop-down list. The default value is default.

      note.svg

      Host and IP Address are unique per VRF, that is, same host name with the same IP Address can exist in multiple VRFs.


    • Host Name - Enter a fully qualified unified hostname for identification.

    • IP Address - Enter the IP address of the host that is part of a flow.

      note.svg

      You can also create host alias before a host sends any data to its directly connected sender or receiver leaf.


  3. Click Submit to apply the changes.

    Click Cancel to discard the host alias.

    The new host alias is shown in the table in the Host Alias window.

Applied Host Polices

UI Navigation

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Applied Host Policies.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Applied Host Policies.

You can view the policies that you have applied in the entire network on this tab.

The table displays default PIM policy, local receiver policy, and sender policy. IPFM does not display user-defined PIM Policies or Receiver External Policies.

Table 17. Applied Host Policies Table Fields and Description

Column Name

Description

VRF

Specifies the VRF for the host.

Policy Name/Sequence #

Specifies the name of the policy applied.

Host Role

Specifies the role of the host.The host device role is either one of the following:

  • PIM

  • Sender

  • Receiver

Switch

Specifies the name of the switch to which the policy is applied.

Interface

Specifies the interface to which the policy is applied.

Active

Specifies if the policy is active or not.

Time Stamp

Specifies the date and time at which the policy was created\deployed.The format is Day, MMM DD YYYY HH:MM:SS (Timezone).

Flows

note.svg

This tab is only available on IPFM fabric when you have deployed IPFM on Nexus Dashboard Fabric Controller.


  • Choose LAN > Fabrics. Click on a fabric to open the Fabric Summary slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts.

Information about flows is also displayed as a card on the Overview tab in the Fabric Overview window. For more information about these cards, see Overview.

The Flows tab comprises the following horizontal tabs:

Flow Status

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Flow Status.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Flow Status.

note.svg

This section is applicable for both the IPFM and Generic Multicast modes in Nexus Dashboard Fabric Controller. Cisco Nexus Dashboard Fabric Controller allows you to view the flow status pictorially and statistically.


In the generic multicast mode, switch reports the receiver interface IP address instead of the receiver endpoint IP address. This IP is displayed in the Flow Status and Topology windows as a host. In the Sender and Receiver fields, the IPs are suffixed with a blue dot and the word Remote to indicate that those IPs are remote hosts. Also, as there’s no policing of the traffic, switch reports only "allowed bytes/packets" and not "denied bytes/packets".

From Release 12.1.1e, NAT type "Egress" is renamed as ENAT, and NAT type "Ingress" is renamed as INAT. Cisco NDFC also displays the NAT direction in the Flow Status table.

  • MUNAT - indicates that the multicast traffic at the egress interface is converted into unicast traffic at receiver interface.

  • UMNAT - indicates that the received multicast traffic at the egress interface is converted into unicast traffic at the sender interface.

Click Unicast or Multicast link in the Receiver/Sender Interface column to view the IP route table at this interface.

note.svg

To view details for a given flow such as all pre/post multicast and source IP-Addresses, post group, post S/DST ports, pre/post NAT policy ID, starting and destination node details, as well as view the topology, click the active hyperlink in Flow Link State for a particular multicast IP. From Release 12.1.1e, a table shows further information about the NAT interface transition type.


From Cisco NDFC Release 12.1.2e, VXLAN EVPN Tenant Routed Multicast (TRM) flows can be visualized in the Flows tab. The flow visualization is for only monitoring existing TRM flows. Clicking on the active link displays the end-to-end flow topology.

In VXLAN TRM, Sources and Receivers associated with an overlay flow are in a customer aka tenant VRF. This tenant traffic is encapsulated in an underlay header which has Encap Source and Encap group (located in default VRF) on the sender VTEP side. The underlay encapsulated flow then reaches the receiver VTEP and is decapsulated here.

The flow topology in NDFC shows the overlay and underlay parts of the flow in different color coding. (purple for underlay and green for overlay).

The following table provides information about the separation between default and tenant VRF and their descriptions:

Table 18. Active Flow Field and Description

Field

Description

Type

Specifies the name of the VRF.

L3VNI

Specifies the tenant VNI.

Encap Source

Specifies the IP address of the encap source from the default VRF.

Encap Group

Specifies the IP address of the encap group from the default VRF.

Click on Telemetry Sync Status link above the table on the top-right corner. The Telemetry Sync Status screen displays the sync status and the IP address of the Telemetry collector for each switch, along with the timestamp at the last sync. To view the load on each Telemetry collector, use the Telemetry Collector == <IP Address of the collector> filter. You can balance the collector performance based on the flows it is currently handling.

Multicast NAT Visualization

Nexus Dashboard Fabric Controller follows the existing flow classification for multicast flows, that is, active, inactive, sender only, or receiver only. With ingress and egress NAT multiple, input and output addresses can be translated to same group. Nexus Dashboard Fabric Controller aggregates these flows per sender and receiver combination and provides visibility into NAT rules through topology. For more information about flow topology for active flows, see RTP/EDI Flow Monitor.

Multicast NAT is supported in the IPFM network, and it is not supported for regular or generic multicast.

You can use the NAT Search field to search for NAT flows. All pre/post multicast and source IP-Addresses are not visible in the Flow Status window. You can view these details for a given flow in a pop-up by clicking the active flow hyperlink. The NAT Search feature allows you to enter the IP address of either pre or post source/multicast group and filter relevant entries. Note that searched IP address may not be visible in main table on filtering as it may be part of pre or post entry that can be seen on corresponding pop-up window.

For NAT flow with NAT type containing Ingress, the source and group will be the post NAT source and post NAT group. For NAT type containing Egress, the source and group will be pre-NAT source and pre-NAT group. NAT rules are displayed on the Sender Only and Receiver Only tabs.

For a NAT flow, the topology graph path tracing shows the NAT badge on the switch which has ingress NAT and shows NAT label on the link to the receiver for egress NAT.

For NAT flow, there is an extra table shown below the topology graph panel to show all the relevant Ingress NAT or Egress NAT information. The NAT Flow information is also available on the Topology window. This information is available when you click the links in the Flow Link State column.

The VRF name is also shown in the slide-in pane for the host and the switch.

For example, sanjose-vrf:2.2.2.2 indicates that the VRF is sanjose-vrf and the host is 2.2.2.2.

The flows carry the VRF name as prefix. If the VRF is default, it will not be displayed.

The following table provides information about the NAT fields and their descriptions:

Table 19. NAT Field and Description

Field

Description

NAT

Specifies the NAT mode, that is, Ingress, Egress, or Ingress and Egress.

For the Ingress NAT type, the following information is displayed:

Ingress (S) - Specifies that ingress NAT is performed on the Sender Switch, also known as First Hop Router (FHR).

Ingress ( R) - Specifies that ingress NAT is performed on the Receiver Switch (also known as Last Hop Router (LHR).

Ingress (S, R) - Specifies that ingress NAT is performed on both the Sender and Receiver Switch.

Pre-Source

Specifies the source IP address before NAT.

Post-Source

Specifies the source IP address after NAT.

Pre-Group

Specifies the multicast group before NAT.

Post-Group

Specifies the multicast group after NAT.

Post S Port

Specifies the source port after NAT.

Post DST Port

Specifies the destination port after NAT.

The following table describes the fields that appear on the Active tab.

Table 20. Active Tab Fields and Descriptions

Field

Description

Common Fields for IPFM and Generic Multicast Modes

VRF

Specifies the name of the VRF for the flow.

Encap

Specifies the name of the encap for the TRM flow.

Multicast IP

Specifies the multicast IP address for the flow.

note.svg

You can click the wave link next to the Multicast IP address to view the pictorial representation of flow statistics.


Flow Alias

Specifies the name of the Flow Alias.

Flow Link State

Specifies the state of the flow link.

Click the active link to view the network diagram or topology of the Sender and Receiver.

The dotted line displays the direction of the flow of traffic. You can hover over the nodes to view information. The table on the right side shows information about the Sender and Receiver.

The flows in the network diagram or topology show the multicast IP as well as the VRF. If the VRF is default, then the VRF will not be shown along with the multicast IP.

Sender

Specifies the IP Address or the Host alias of the sender for the multicast group.

NAT

Specifies whether the flow is ingress, egress, or both ingress and egress.

Sender Switch

Specifies if the Sender switch is a leaf or spine.

Sender Interface

Specifies the interface to which the sender is connected to.

Receiver Switch

Specifies if the Receiver switch is a leaf or spine.

Receiver Interface

Specifies the interface to which the receiver is connected to.

Sender Start Time

Displays the time from when the sender joined.

Receiver Join Time

Specifies the time at which the receiver joined.

Fields Specific for IPFM Mode

Priority

Specifies the flow priority for flows.

Policed

Specifies whether a flow is policed or not policed.

Receiver

Specifies the IP Address or the Host alias of the receiver joining the group.

Bandwidth

Specifies the bandwidth that is allotted for the traffic.

QOS/DSCP

Specifies the Switch-defined QoS Policy.

Policy ID

Specifies the policy ID applied to the multicast IP.

Field Specific for Generic Multicast Mode

Receiver Interface IP

Specifies the IP address of the receiver interface joining the group.

The following table describes the fields that appear on the Inactive tab.

Table 21. Inactive Tab Fields and Descriptions

Field

Description

Common Fields for IPFM and Generic Multicast Modes

VRF

Specifies the name of the VRF for the flow.

Multicast IP

Specifies the multicast IP address for the flow.

note.svg

You can click the chart link next to the Multicast IP address to view the pictorial representation of flow statistics.


Flow Alias

Specifies the name of the Flow Alias.

NAT

Specifies whether the flow is ingress, egress, or both ingress and egress.

Sender

Specifies the IP Address or the Host alias of the sender for the multicast group.

Sender Start Time

Displays the time from when the sender joined.

Receiver Join Time

Specifies the time at which the receiver joined.

Fields Specific for IPFM Mode

Priority

Specifies the flow priority for flows.

Policed

Specifies whether a flow is policed or not policed.

Receiver

Specifies the IP Address or the Host alias of the receiver joining the group.

Bandwidth

Specifies the bandwidth that is allotted for the traffic.

QOS/DSCP

Specifies the Switch-defined QoS Policy.

Policy ID

Specifies the policy ID applied to the multicast IP.

Fault Reason

Specifies reason for the inactive flow.Cisco Nexus Dashboard Fabric Controller determines the inactive flow if both the sender and receiver mroute exists with any of the following combinations. * Receiver IIF is null * Receiver OIF is null * Sender IIF is null * Sender OIF is null

In this scenario, the switch will not have any fault reason. Therefore, there is no fault reason for such inactive flows.

Field Specific for Generic Multicast Mode

Receiver Interface IP

Specifies the IP address of the receiver interface joining the group.

The following table describes the fields that appear on the Sender Only tab.

Table 22. Sender Only Tab Field and Description

Field

Description

Common Fields for IPFM and Generic Multicast Modes

VRF

Specifies the name of the VRF for the flow.

Multicast IP

Specifies the multicast IP address for the flow.

Flow Alias

Specifies the name of the Flow Alias.

Flow Link State

Specifies the flow link state, if it’s allow or deny.

Click the senderonly link to view the network diagram or topology of the Sender and Receiver.

The dotted line displays the direction of the flow of traffic. You can hover over the nodes to view information. The table on the right side shows information about the Sender and Receiver.

The flows in the network diagram or topology show the multicast IP as well as the VRF. If the VRF is default, then the VRF will not be shown along with the multicast IP.

Sender

Specifies the name of the sender.

NAT

Specifies whether the flow is ingress, egress, or both ingress and egress.

Sender Switch

Specifies the IP address of the sender switch.

Sender Ingress Interface

Specifies the name of the sender ingress interface.

Sender Start Time

Displays the time from when the sender switch is transmitting information.

Fields Specific for IPFM Mode

Policed

Specifies whether a flow is policed or not policed.

Policy ID

Specifies the policy ID applied to the multicast IP.

Bandwidth

Specifies the bandwidth that is allotted for the traffic.

QOS/DSCP

Specifies the Switch-defined QoS Policy.

Priority

Specifies the flow priority for flows.

The following table describes the fields that appear on the Receiver Only tab.

Table 23. Receiver Only Tab Field and Description

Field

Description

Common Fields for IPFM and Generic Multicast Modes

VRF

Specifies the name of the VRF for the flow.

Multicast IP

Specifies the multicast IP address for the flow.

Flow Alias

Specifies the name of the Flow Alias.

Flow Link State

Specifies the flow link state, if it’s allow or deny.

Click the receiveronly link to view the network diagram or topology of the Sender and Receiver.

The dotted line displays the direction of the flow of traffic. You can hover over the nodes to view information. The table on the right side shows information about the Sender and Receiver.

The flows in the network diagram or topology show the multicast IP as well as the VRF. If the VRF is default, then the VRF will not be shown along with the multicast IP.

Source Specific Sender

Specifies the IP address of the multicast sender.

Receiver

Specifies the receiver ID. If the multicast receiver is remote, the Remote label can be seen next to its name.

NAT

Specifies whether the flow is ingress, egress, or both ingress and egress.

Receiver Switch

Specifies the IP address of the receiver switch.

Receiver Interface

Specifies the name of the destination switch interface.

Receiver Join Time

Specifies the time at which the receiver joined.

Fields Specific for IPFM Mode

Bandwidth

Specifies the bandwidth that is allotted for the traffic.

Policy ID

Specifies the policy ID applied to the multicast IP.

Priority

Specifies the flow priority for flows.

QOS/DSCP

Specifies the Switch-defined QoS Policy.

note.svg

If stats are enabled on switches, only then they can be seen in Nexus Dashboard Fabric Controller.


Click the Show drop-down list in the statistical representation area to display the statistical data in various formats.

Click the arrow to export the statistical data. You can export it in .csv or .pdf formats.

note.svg

Cisco Nexus Dashboard Fabric Controller holds the Flow statistics values in the Nexus Dashboard Fabric Controller server internal memory. Therefore, after a Nexus Dashboard Fabric Controller Restart or HA switch over, the Flow statistics won’t show previously collected values. However, you can see the Flow statistics that are collected after the server Restart or HA switch over.
If the new flow joins before the uplinks between the switches that are detected in Nexus Dashboard Fabric Controller, a message BW_UNAVAIL appears. This is resolved after the uplinks between the switches are detected by Nexus Dashboard Fabric Controller after discovery of the devices.


Flow Policies

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Flow Policies.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Flow Policies.

Use this window to configure the flow policies.

note.svg

When a user logs in to Nexus Dashboard Fabric Controller with a network operator role, all the buttons or options to add, delete, modify, import, export, or deploy policies are disabled. This user can only view policies, and deployment status or history.


The default policies are displayed on the Flow Policies tab. By default, the bandwidth of these policies is 0. You can configure the bandwidth such that any flow that matches the default flow policy will accordingly use the bandwidth and QOS/DSCP parameters. The policy is deployed to all the devices when you save the configuration.

note.svg

When you undeploy a default policy, it will be reset to default values, that is, Bandwidth:0gbps, DSCP:Best Effort, and Policer:Enabled.


Policies are automatically deployed to switches whenever they are created, edited, or imported. You can choose to undeploy or redeploy the policies, by choosing the appropriate actions in the Actions drop-down list. The policies will not be deployed correctly if the device is rebooting while the policy was deployed. In such case, the Failed message appears in the Deployment Status column.

The default flow policies must be deployed successfully to the switch before you deploy the custom flow policies on that switch. Otherwise, the custom policies will fail to deploy. Ensure that you deploy all default policies successfully to all the switches before you add, edit, import, or deploy custom policies.

note.svg

If you have created a custom or non-default VRF, although the host and flow policies are automatically created for the VRF, use the action options in this window to manually deploy the flow policies to the switches in the fabric.


The following table describes the fields that appear on this page.

Table 24. Flow Policies Table Field and Description

Field

Description

VRF

Specifies the name of the VRF for the flow policy.

Policy Name

Specifies the flow policy name.

Multicast IP Range

Specifies the multicast IP address for the traffic. Click view to view the details such as starting and ending IP addresses of the multicast range as well as the flow priority in the Multicast Range List box.

Bandwidth

Specifies the bandwidth that is allotted for the traffic.

QoS/DSCP

Specifies the Switch-defined QoS Policy.

Deployment Action

Specifies the action that is performed on the switch for that host policy.

  • Create - The policy is deployed on the switch.

  • Delete - The policy is undeployed from the switch.

Deployment Status

Specifies if the flow policy is deployed successfully, not deployed, or failed.

In Use

Specifies if the flow policy is in use or not.

Policer

Specifies whether the policer for a flow policy is enabled or disabled.

note.svg

In adding or editing a flow policy, the default policer state is Enabled.


Last Updated

Specifies the date and time at which the flow policy was last updated.

The format is Day MMM DD YYYY HH:MM:SS Timezone.

Click the table header to sort the entries in alphabetical order of that parameter.

The following table describes the action items, in the Actions drop-down list, that appears in the Flow Policies horizontal tab on the Flows tab in the Fabric Overview window.

note.svg

A new flow policy or an edited flow policy is effective only under the following circumstances:
- If the new flow matches the existing flow policy.
- If the flow expires and reforms, while the new policy is already created or edited, that matches with the flow policy.


Table 25. Flow Policies Actions and Description

Field

Description

Create Flow Policy

Allows you to create a new flow policy. For more information, see Creating a Flow Policy.

Edit Flow Policy

Allows you to view or edit the selected flow policy parameters.

note.svg

The default flow policies must be deployed successfully to the switch before you deploy the custom flow policies on that switch. Otherwise, the custom policies will fail to deploy. Ensure that you deploy all default policies successfully to all the switches before you edit custom policies.


To edit a flow policy for a VRF, select the check box next to the VRF and choose Edit Flow Policy action. In the Edit Flow Policy window, you can make the required changes and click Save & Deploy to deploy the changes or click Cancel to discard the changes.

The deployment completed message appears at the bottom of the window. You can click Refresh to refresh the current deployment status in the window or click View Details to verify the deployment details.

Delete Flow Policy

Allows you to delete the user-defined flow policy.

note.svg

* You cannot delete the default flow policies.
* Undeploy policies from all switches before deleting them from Nexus Dashboard Fabric Controller.
* You can select more than one flow policy to delete.


To delete a flow policy, select the check box next to that VRF and choose the Delete Flow Policy action. A warning message appears asking you to undeploy policies from the switches. Click Confirm to proceed with deletion and leave the policies on the switches or click Cancel to discard the delete operation.

Purge

Allows you to delete all the flow policies at a single instance.

note.svg

Undeploy policies from all switches before deleting them from Nexus Dashboard Fabric Controller.


To delete all flow policies, choose the Purge action. A warning message appears asking you to undeploy policies from all the switches. Click Confirm to proceed with deletion and leave the policies on the switches or click Cancel to discard the delete operation.

Import

Allows you to import flow policies from a csv file.

note.svg

The default flow policies must be deployed successfully to the switch before you deploy the custom flow policies on that switch. Otherwise, the custom policies will fail to deploy. Ensure that you deploy all default policies successfully to all the switches before you import custom policies.
After import, all policies imported from a csv file are applied to all managed switches automatically.


To import the flow policies, choose the Import action. Browse the directory and select the .csv file that contains the flow policy configuration information. The policy will not be imported if the format in the .csv file is incorrect. Click Open. The imported policies are automatically deployed to all the switches in the fabric.

Export

Allows you to export flow policies to a csv file.

To export the flow policies, choose the Export action. Select a location on your local system directory to store the flow policy details file. Click Save. The flow policy file is exported to your local directory. The file name is appended with the date on which the file is exported. The format of the exported file is .csv.

Deploy Selected Policies

Select this option to deploy only the selected policies to the devices. You can deploy other policies when required.

Select one or more check boxes next to the policy name. Select this option to deploy selected policies to the switch.

Deploy All Custom Policies

Select this option to deploy all the custom or user-defined policies at a single instance.

The policies are deployed even if the switch is rebooting. In such case, the deployment fails and a status message Failed appears in the Deployment Status column.

Deploy All Default Policies

Select this option to deploy all default policies to the switch.

Undeploy Selected Policies

Select this option to undeploy the selected policies.

To undeploy the selected policies, select one or more check boxes next to the VRFs. Select this option from the drop-down list to undeploy the selected policies.

Undeploy All Custom Policies

Select this option to undeploy all the custom or user-defined policies at a single instance.

Undeploy All Default Policies

Select this option to undeploy all the default policies at a single instance.

Redo All Failed Policies

The deployment or undeployment of policies may fail due to various reasons. Select this option to deploy all the failed policies.

All the deployments that failed on switches previously will be deployed again to only those switches. All the undeployments that failed on switches previously will be undeployed again from only those switches.

Deployment History

Select this option to view the deployment history of the selected policy for the switch in the Deployment History pane.

The Deployment History pane displays the following fields:

  • Policy Name - Specifies the selected policy name.

  • VRF - Specifies the VRF for the selected policy.

  • Switch Name - Specifies the name of the switch that the policy was deployed to.

  • Deployment Status - Displays the status of deployment. It shows if the deployment was a success, failed, or not deployed. Click on the deployment status, for example, Success, to see more details. For more information about the deployment status, see !!!Dita2Adoc_MissingReference:!!!.

  • Action - Specifies the action that is performed on the switch for that flow policy.

    • Create - Implies that the policy has been deployed on the switch.

    • Delete - Implies that the policy has been undeployed from the switch.

  • Deployment Date/Time - Specifies the date and time at which the host policy was last updated. The format is Day MMM DD YYYY HH:MM:SS Timezone .

  • Failed Reason - Species why the policy was not successfully deployed.

Deployment Status

The following table describes the fields that appear on the Deployment Status.

Table 26. Deployment Status Field and Description

Field

Description

Policy Name

Specifies the name of the flow policy.

VRF

Specifies the name of the VRF.

Switch Name

Specifies the switch on which the VRF is deployed.

IP Address

Specifies the IP address of the switch.

Deployment Status

Displays the status of the deployment. It shows if the deployment was a Success or Failed along with the reason why the deployment failed.

Action

Specifies the action that is performed on the switch, for example, Create.

Deployment Date/Time

Displays the date and time when the deployment was initialized.

This section contains the following:

Creating a Flow Policy

note.svg

The default host policies must be deployed successfully to the switch before you deploy the custom host policies on that switch. Otherwise, the custom policies will fail to deploy. Ensure that you deploy all the default policies successfully to all the switches before you add custom policies.


To create a flow policy from the Cisco Nexus Dashboard Fabric Controller Web UI, perform the following steps:

  1. Click Actions*and choose*Create Flow Policy.

    The Create Flow Policy window is displayed.

  2. In the Create Flow Policy window, specify the parameters in the following fields.

    • VRF - Click the Select a VRF link to open the Select a VRF window. The default VRF is also listed in the window. Search and select a VRF for the host and click Save.

      note.svg

      - Policy names can be repeated across VRFs, that is, they are unique only within a VRF.
      - Across the VRF, host policies may be same or different.
      - Sequence number for the host policies is per VRF.


    • Policy Name - Specify a unique policy name for the flow policy.

    • Bandwidth - Specifies the bandwidth that is allocated for the flow policy. Select of the radio buttons to choose Gbps, Mbps, or Kbps.

  3. From the QoS/DSCP drop-down list, choose an appropriate ENUM value.

  4. Click the Policer check box to enable or disable policer for a flow.

  5. In Multicast IP Range, enter the beginning IP and ending IP Address for the multicast range in the From and To fields. The valid range is between 224.0.0.0 and 239.255.255.255.

    From the Flow Priority drop-down list, choose the priority for the flow. You can choose either Default or Critical. The default value is Default.

    The flow priority is used during the following scenarios:

    • Error Recovery - Unicast Routing Information Base (URIB) reachability changes on flows, and a re-Reverse-path forwarding (RPF) is being performed. When a set of existing flows is retried, the recovery starts from the flows with Critical priority.

    • Flow Retry - When pending flows are retried, the Critical priority flows are retried first.

    Actions - Actions has a variety of icons to perform various actions. Click the tick mark icon if you have entered the correct details; if not, click the check mark icon to add the multicast range to the policy. Click the edit icon if you want to modify the details or click the bin icon to delete the row. Click the Plus (+) mark to add another row.

  6. Click Save & Deploy to deploy the new policy or click Cancel to discard the changes. The deployment completed message appears at the bottom of the window. You can click Refresh to refresh the current deployment status in the window or click View Details to verify the deployment details.

Flow Alias

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Flows > Flow Alias.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Flows > Flow Alias.

Use this tab to configure flow alias.

note.svg

This section is applicable for both the IPFM and Generic Multicast modes in Nexus Dashboard Fabric Controller.


Using the Flow Alias feature, you can specify names for multicast groups. The multicast IP addresses are difficult to remember, thus by assigning a name to the multicast IP address, you can search and add policies based on the name.

The following table describes the fields that appear in this window.

Table 27. Flow Alias Table Field and Description

Field

Description

VRF

Specifies the VRF for the flow alias.

Policy Name

Specifies the policy name.

Multicast IP Range

Specifies the multicast IP address for the traffic.

Description

Description added to the flow alias.

Last Updated

Specifies the date on which the flow alias was last updated.

The following table describes the action items, in the Actions drop-down list, that appears in the Flow Alias horizontal tab on the Flows tab of the Fabric Overview window.

Table 28. Flow Alias Actions and Description

Action Item

Description

Create Flow Alias

Allows you to create a new flow alias. For instructions about creating a new flow alias, see Creating Flow Alias.

Edit Flow Alias

Allows you to view or edit the selected flow alias parameters.

To edit the flow alias, select the check box next to the flow alias that you want to delete and choose Edit Flow Alias. In the Edit Flow Alias*window, edit the required values and click *Submit to apply the changes or click Cancel to discard the flow alias. The edited flow alias is shown in the table in the Flow Alias window.

Delete Flow Alias

Allows you to delete the flow alias.

To delete a flow alias, select the check box next to the flow alias that you want to delete and choose Delete Flow Alias. You can select multiple flow alias entries and delete them at the same instance.

Import

Allows you to import flow aliases for devices in the fabric.

To import flow aliases, choose Import. Browse the directory and select the .csv file that contains the flow IP address and corresponding unique flow name information. Click Open. The flow aliases are imported and displayed in the *Flow Alias*window.

Export

Allows you to export flow aliases for devices in the fabric.

To export a flow alias, choose Export. Select a location on your local system directory to store the flow aliases configuration from Nexus Dashboard Fabric Controller and click Save. The flow alias configuration file is exported to your local directory. The file name is appended with the date and time at which the file was exported. The format of the exported file is .csv.

This section contains the following:

Creating Flow Alias

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Flows > Flow Alias.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Flows > Flow Alias.

To create a flow alias from the Cisco Nexus Dashboard Fabric Controller, perform the following steps:

  1. In the Flow Alias window, from the Actions drop-down list, choose Create Flow Alias.

  2. In the Create Flow Alias window, enter the following:

    note.svg

    All the fields are mandatory.


    • VRF - Select the VRF from this drop-down list. The default value is default.

      note.svg

      Host and IP Address are unique per VRF, that is, same host name with the same IP Address can exist in multiple VRFs.


    • Flow Name - Enter a fully qualified unique flow name for identification of the flow alias.

    • Multicast IP Address - Enter the multicast IP address for the flow alias.

    • Description - Enter a description for the flow alias.

  3. Click Submit to apply the changes.

    Click Cancel to discard the flow alias.

    The new flow alias is shown in the table in the Flow Alias window.

Static Flow

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Hosts > Static Flow.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Hosts > Static Flow.

You configure a static receiver using the Static Flow window. Use the Select an Option field to select a switch before creating a static flow for it.

Table 29. Static Flow Actions and Description

Field

Description

Create Static Flow

Allows you to create a static flow. For more information, see Creating a Static Flow.

Delete Static Flow

Allows you to delete the static flow.Select a static flow that you need to delete and click the Delete Static Flow action to delete the selected static flow.

Table 30. Static Flow Table Field and Description

Field

Description

VRF

Specifies the VRF for a static flow.

Group

Specifies the group for a static flow.

Source

Specifies the source IP address for the static flow.

Interface Name

Specifies the interface name for the static flow. If it is not specified while creating the static flow, it is displayed as N/A.

Deployment Action

Specifies the action that is performed on the switch for the rule. Create implies that the static flow has been deployed on the switch. Delete implies that the static flow has been undeployed from the switch.

Deployment Status

Specifies if the static flow is deployed or not. If there is a deployment failure, hover over the information icon to view the failure reason.

Last Updated

Specifies the date and time at which the static flow was last updated.The format is Day MMM DD YYYY HH:MM:SS Timezone.

Creating a Static Flow

Before you begin:

Select a switch in the Static Flow tab of the Fabric Overview window before creating a static flow for it.

To create a static flow for the selected switch, perform the following steps:

  1. Click Actions*and choose*Create Static Flow.

    The Create Static Flow window is displayed.

  2. In the Create Static Flow window, specify the parameters in the following fields.

    Switch - Specifies the switch name. This field is read-only, and it is based on the switch selected in the Static Flow window.

    Group - Specifies the multicast group.

    Source - Specifies the source IP address.

    Interface Name - Specify the interface name for the static flow. This field is optional. If you do not specify an interface name, the host IP 0.0.0.0 is passed to the API and config is created using Null0 interface.

  3. Click Save & Deploy to save the static flow.

    Click Cancel to discard it.

Metrics

The Metrics tab displays the infrastructure health and status. You can view CPU utilization, Memory utilization, Traffic, Temperature, Interface, and Links details.

note.svg

Metrics tab is available only if you have enabled Performance Monitoring feature in Cisco Nexus Dashboard Fabric Controller.


Perform the following steps to navigate to the Metrics tab:

  1. In Cisco Nexus Dashboard Fabric Controller, choose LAN > Fabrics.

  2. Double-click the fabric name to open the Fabric Overview page.

  3. Click on the Metrics tab.

The following table describes the columns that appear on the CPU and Memory tab.

Fields Descriptions

Switch Name

Specifies the name of the switch.

IP Address

Specifies the switch IP address.

Low Value (%)

Specifies the lowest CPU/memory utilization value on the switch.

Avg. Value (%)

Specifies the average CPU/memory utilization value on the switch.

High Value (%)

Specifies the high CPU/memory utilization value on the switch.

Range (Preview)

Specifies the linear range preview.

Last Update Time

Specifies the last updated time on the switch.

Show last day

Click Show last day to view data for selected day, week, month, and year.

The following table describes the columns that appear on the Traffic tab.

note.svg

Inbound discards data is not available for Cisco Catalyst switches.


Fields Descriptions

Switch Name

Specifies the name of the switch.

Avg. Rx

Specifies the average Rx value.

Peak Rx

Specifies the peak Rx value.

Avg. Tx

Specifies the average Tx value.

Peak Tx

Specifies the peak Tx value.

Avg. Rx+Tx

Specifies the average of Rx and Tx value.

Avg. Errors

Specifies the average error value.

Peak Errors

Specifies the peak error value.

Avg. Discards

Specifies the average discard value.

Peak Discards

Specifies the peak discard value.

Last Update Time

Specifies the last updated time.

Show last day

Click Show last day to view data for selected day, week, month, and year.

The following table describes the columns that appears on Temperature tab.

note.svg

Temperature specifications for Cisco Catalyst switches are currently not available.


Fields Descriptions

Switch Name

Specifies the name of switch.

IP Address

Specifies the switch IP address.

Temperature Module

Specifies the module of temperature.

Low Value ©

Specifies the lowest temperature value.

Avg. Value ©

Specifies the average temperature value.

High Value ©

Specifies the high temperature value.

Show last day

Click Show last day to view data for selected day, week, month, and year.

The following table describes the columns that appears on Interface tab.

Fields Descriptions

Switch

Specifies the name of the switch.

Interface

Specifies the name of the interface

Description

Specifies the description of the interface.

Speed

Specifies the speed of the interface.

Status

Specifies the status of switch link.

Rx.

Avg.

Specifies the average Rx value.

Avg%

Specifies the average percentage of Rx value.

Peak

Specifies the peak Rx value.

Peak%

Specifies the peak percentage Rx value.

Tx.

Avg.

Specifies the average Tx value.

Avg%

Specifies the average percentage of Tx value.

Peak

Specifies the peak Tx value.

Peak%

Specifies the peak percentage Tx value.

Rx+Tx

Specifies the sum value of Rx and Tx.

Errors

In Avg.

Specifies the inbound average error value.

Out Avg.

Specifies the outbound peak error value.

In Peak

Specifies the inbound peak error value.

Out Peak

Specifies the outbound peak error value.

Discards

In Avg.

Specifies the average discard value.

Out Avg.

Specifies the peak discard value.

In Peak

Specifies the inbound peak discard value.

Out Peak

Specifies the outbound peak discard value.

Show last day

Click Show last day to view data for selected day, week, month, and year.

The following table describes the columns that appears on Link tab.

Fields Descriptions

Switch

Specifies the name of the switch.

Speed

Specifies the switch speed.

Status

Specifies the status of switch.

Rx.

Avg.

Specifies the average Rx value.

Avg%

Specifies the average percentage of Rx value.

Peak

Specifies the peak Rx value.

Peak%

Specifies the peak percentage Rx value.

Tx.

Avg.

Specifies the average Tx value.

Avg%

Specifies the average percentage of Tx value.

Peak

Specifies the peak Tx value.

Peak%

Specifies the peak percentage Tx value.

Rx+Tx

Specifies the sum value of Rx and Tx.

Errors

In Avg.

Specifies the inbound average error value.

Out Avg.

Specifies the outbound peak error value.

In Peak

Specifies the inbound peak error value.

Out Peak

Specifies the outbound peak error value.

Discards

In Avg.

Specifies the average discard value.

Out Avg.

Specifies the peak discard value.

In Peak

Specifies the inbound peak discard value.

Out Peak

Specifies the outbound peak discard value.

Show last day

Click Show last day to view data for selected day, week, month, and year.

Multicast NAT

Multicast NAT translation of UDP stream is supported on the Nexus Dashboard Fabric Controller IPFM mode. You can apply NAT for the incoming traffic (ingress), or on the egress link or interface. The scope of ingress NAT is entire switch, whereas egress NAT is for a specific interface. The same switch can have both ingress and egress NAT. However, it can’t be on the same flow for a given switch. Egress NAT has capability to replicate the same flow up to 40 times. To achieve this function, the service-reflect interface is defined on the switch. It serves for multiple or single egress port.

note.svg

Ingress and/or Egress NAT translation is supported only on the sender switch, also known as First Hop Router (FHR), and receiver switch, also known as Last Hop Router (LHR). It is not supported on intermediates nodes such as spine switches.


For more information about NAT, see Cisco Nexus 9000 Series NX-OS IP Fabric for Media Solution Guide.

Prerequisites

  • Set up loopback interface with PIM sparse mode. When flow is translated, post-translated source needs to be secondary IP address on this loopback to make sure RPF check won’t fail. This loopback is configured as service reflect interface for NAT purpose. You need to set up lookback per VRF.

    Here is an example to configure the loopback interface:

    interface loopback10
    ip router ospf 1 area 0
    ip pim sparse-mode
    ip address 192.168.1.1/32
    ip address 172.16.1.10/32 secondary
    
    ip service-reflect source-interface loopback10
  • TCAM memory carving must be completed.

    The command to configure the TCAM for Multicast NAT is as follows:

    hardware access-list tcam region mcast-nat _tcam-size_

    For information about switch models that support multicast NAT, see Configuring Multicast Service Reflection with NBM in Cisco Nexus 9000 Series NX-OS IP Fabric for Media Solution Guide.

NAT Modes

NAT ModesNAT Mode objects are created per switch and VRF. The switches are populated in the drop-down based on the scope. You should select the switch to list and operate on the corresponding NAT Mode objects.

Choose LAN > Fabrics. Double-click a fabric name and click Multicast NAT > NAT Modes to configure NAT modes.

The following table describes the fields that appear on the NAT Modes tab.

Field

Description

VRF

Specifies the VRF for the multicast NAT. VRF support is not applicable for eNAT, however, it is applicable for iNAT.

Group

Specifies the multicast address of the NAT mode.

Mode

Specifies the multicast NAT mode, that is, ingress or egress.

Deployment Action

Specifies the action that is performed on the switch for that mode. Create implies that the mode has been deployed on the switch. Delete implies that the mode has been undeployed from the switch.

Deployment Status

Specifies if the mode is deployed or not. If there’s deployment failure, hover over the information icon to view the failure reason.

Last Updated

Specifies the date and time at which the mode was last updated.

The format is Day MMM DD YYYY HH:MM:SS Timezone.

The following table describes the action items, in the Actions menu drop-down list, that appear on the NAT Modes tab.

Action Item

Description

Create NAT Mode

Choose Create NAT Mode to add a NAT mode.

Delete NAT Mode

Select a mode from the table and choose Delete NAT Mode to delete the mode.

Import

Allows you to import NAT modes from a CSV file to Nexus Dashboard Fabric Controller.

Export

Allows you to export NAT modes from Nexus Dashboard Fabric Controller to a CSV file.

Deploy Selected NAT Modes

Select modes from the table and choose Deploy Selected NAT Modes to deploy selected modes to the switch.

Deploy All NAT Modes

Choose Deploy All NAT Modes to deploy all modes to the switch.

Undeploy Selected NAT Modes

Select modes from the table and choose Undeploy Selected NAT Modes to undeploy selected modes from the switch.

Undeploy All NAT Modes

Choose Undeploy All NAT Modes to undeploy all modes from the switch.

Redo All Failed NAT Modes

Choose Redo All Failed NAT Modes to deploy all failed modes.

Deployment History

Select a mode from the table and choose Deployment History to view the deployment history of the selected mode.

Deployment History shows the following fields.

  • Switch Name─Specifies the name of the switch that the mode was deployed to.

  • VRF─Specifies the name of the VRF that mode was deployed to.

  • Group─Specifies the multicast group of the NAT mode.

  • Mode─Specifies the NAT mode, that is, ingress or egress.

  • Deployment Status─Displays the status of deployment. It shows if the deployment was Success or Failed.

  • Action─Specifies the action that is performed on the switch for that mode. Create implies that the mode has been deployed on the switch. Delete implies that the mode has been undeployed from the switch.

  • Deployment Date/Time─Specifies the date and time at which the mode was last updated. The format is Day MMM DD YYYY HH:MM:SS Timezone.

  • Failed Reason─Specifies why the mode wasn’t successfully deployed.

Adding a NAT Mode

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Multicast NAT tab.

  4. Click the NAT Modes tab.

  5. Click Actions > Create NAT Mode to add a NAT mode.

    The Add NAT Mode window appears.

  6. In the Add NAT Mode window, specify the following information:

    Mode: Select the multicast NAT mode, that is, Ingress or Egress.

    Selected Switch: Specifies the switch name. This field is read-only, and it’s based on the switch selected in the NAT Modes tab.

    VRF: Select the VRF to which the NAT mode should belong to.

    Group / Mask: Specify the multicast group with the mask. The same group can’t be ingress as well as egress NAT on a given switch. You need to identify whether particular group or mask would be ingress or egress.

  7. Click Save & Deploy to save the NAT mode and deploy it.

Deleting a NAT Mode

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Multicast NAT tab.

  4. Click the NAT Modes tab.

  5. Select the NAT mode that you need to delete and click Actions > Delete NAT Mode to delete a NAT mode.

    If the NAT mode isn’t deployed or failed, you can skip this step.

  6. Click Confirm to delete the selected NAT mode.

Recirc Mappings

NDFC allows you to map recirculation packets across ports for ingress or egress interfaces. From Release 12.1.1e, you can configure recirc mappings for the following translation types:

  • Multicast-to-Multicast

  • Multicast-to-Unicast

  • Unicast-to-Multicast

Choose LAN > Fabrics. Double-click a fabric name and click Multicast NAT > Recirc Mappings to configure recirc mappings.

The following table describes the fields that appear on the Recirc Mappings tab.

Field

Description

VRF

Specifies the VRF over which the recirc mapping is routed.

Egress Interfaces

Specifies the egress interfaces for the mapping.

Destination/Prefix

Specifies the IP address of the destination unicast interface

Map Interface

Specifies the map interface.

Egress interfaces and map interface have Many to One relationship. When there are more than one Egress Interfaces for a mapping, it is shown as a hyperlink. You can click on the hyperlink to see the complete list of interfaces.

Max Replications

Specifies the max replications for the map interface.

Deployment Action

Specifies the action that is performed on the switch for that egress interface mapping. Create implies that the egress interface mapping has been deployed on the switch. Delete implies that the egress interface mapping has been undeployed from the switch.

Deployment Status

Specifies if the egress interface mapping is deployed or not. If there’s deployment failure, hover over the information icon to view the failure reason.

Last Updated

Specifies the date and time at which the egress interface mapping was last updated.

The format is Day MMM DD YYYY HH:MM:SS Timezone.

The following table describes the action items, in the Actions menu drop-down list, that appear on the Recirc Mappings tab.

Action Item

Description

Create NAT Recirc Mapping

Choose Create NAT Recirc Mapping to add an Recirc mapping.

Edit NAT Recirc Mapping

Select a mode from the table and choose Edit NAT Recirc Mapping to edit an Recirc mapping.

Delete NAT Recirc Mapping

Select a mode from the table and choose Delete NAT Recirc Mapping to delete an Recirc mapping.

Import

Allows you to import NAT egress interface mappings from a CSV file to Nexus Dashboard Fabric Controller.

Export

Allows you to export NAT Recirc mappings from Nexus Dashboard Fabric Controller to a CSV file.

Deploy Selected NAT Recirc Mappings

Select modes from the table and choose Deploy Selected NAT Recirc Mappings to deploy selected Recirc mapping to the switch.

Deploy All NAT Recirc Mappings

Choose Deploy All NAT Recirc Mappings to deploy all Recirc mappings to the switch.

Undeploy Selected NAT Recirc Mappings

Select modes from the table and choose Undeploy Selected NAT Recirc Mappings to undeploy selected Recirc mappings from the switch.

Undeploy All NAT Recirc Mappings

Choose Undeploy All NAT Recirc Mappings to undeploy all Recirc mapping from the switch.

Redo All Failed NAT Recirc Mappings

Choose Redo All Failed NAT Recirc Mappings to deploy all failed Recirc mappings.

Deployment History

Select a Recirc Mapping from the table and choose Deployment History to view the deployment history of the selected Recirc mapping.

Deployment History shows the following fields.

  • Switch Name─Specifies the name of the switch that the mode was deployed to.

  • VRF─Specifies the VRF used to configure the selected recirc mapping.

  • Map Interface─Specifies the map interface for the Recirc mappings.

  • Max Replications─Specifies the maximum replications for the Recirc mappings.

  • Egress Interfaces*or*Destination/Prefix─Specifies the interface over which Recirc mapping is configured.

  • Deployment Status─Displays the status of deployment. It shows if the deployment was Success or Failed. If failed, the reason is displayed.

  • Action─Specifies the action that is performed on the switch for that Recirc mapping. Create implies that the mapping has been deployed on the switch. Delete implies that the mapping has been undeployed from the switch.

  • Deployment Date/Time─Specifies the date and time at which the mapping was last updated. The format is Day MMM DD YYYY HH:MM:SS Timezone.

Adding Recirc Mapping

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Multicast NAT > Recirc Mappings tab.

  4. From the Selected Switch drop-down list, select switch on which you want to create recirc mappings.

  5. Click Actions > Create Recirc Mapping to add a recirculation mapping for the selected switch.

    The Add Recirc Mappings window appears.

  6. In the Add Recirc Mappings window, Selected Switch field specifies the switch name.

    This field is read-only, and it’s based on the switch selected in the Recirc Mappings window.

  7. From the VRF drop-down list, select the vrf over which the recirc is routed.

  8. In the Translation Type, select one of the translation types:

    • Multicast-to-Multicast

    • Multicast-to-Unicast

    • Unicast-to-Multicast

  9. If you selected Multicast-to-Multicast transition type, in the Egress Interfaces area, select one of the following:

    • All - Choose All to select all the interfaces

    • Select one or more - You can select multiple Egress Interfaces by selecting the Select one or more option and click the Select option to choose the interfaces. The Select window shows the interfaces that are available, that is, the interfaces that are already defined in other mappings are filtered out. To select all the interfaces, you can select All. When All is selected, the option to select individual egress interfaces is disabled.

  10. Based on the transition type, do the following:

    • If you selected Multicast-to-Unicast transition type, enter the IP address of the destination unicast interface in the Destination/Prefix field.

    • If you selected Unicast-to-Multicast transition type, enter the IP address of the destination multicast interface in the Destination/Prefix field.

  11. From the Map Interface drop-down list, select an interface to start recirc mapping.

    An interface can either be an Egress Interface or a Map Interface and can’t be both. An error is displayed if you select a map interface that is already selected as an Egress Interface.

  12. In the Max Replications field, enter the maximum replications for the map interface. The range for this field is 1-40. The default value is 40.

  13. Click Save & Deploy to save the NAT mode and deploy it.

NAT Rules

NAT RulesNAT rules are identical for ingress and egress NAT except you need to also specify receiver OIF for egress NAT.

Choose LAN > Fabrics. Double-click a fabric name and click Multicast NAT > NAT Rules to configure NAT rules.

The following table describes the fields that appear on the NAT Rules tab.

Field

Description

VRF

Specifies the VRF for the multicast NAT.

Mode

Specifies the NAT mode, that is, ingress or egress.

Pre-Translation Group

Specifies the multicast group before NAT.

Post-Translation Group

Specifies the multicast group after NAT.

Group Mask

Specifies the group mask.

Pre-Translation Source

Specifies the source IP address before NAT.

Post-Translation Source

Specifies the source IP address after NAT.

Source Mask

Specifies the source mask.

Post-Translation Source Port

Specifies the source port after NAT. The range is 0-65535. The value 0 means that there’s no translation of UDP source port.

Post-Translation Destination Port

Specifies the destination port after NAT. The value 0 means that there’s no translation of UDP destination port.

Static Oif

Specifies the static outgoing interface to bind the Egress NAT rule to. This drop-down is populated with Egress Interfaces defined in the Egress Interface Mappings window. This field is disabled for Ingress mode.

Deployment Action

Specifies the action that is performed on the switch for the rule. Create implies that the rule has been deployed on the switch. Delete implies that the rule has been undeployed from the switch.

Deployment Status

Specifies if the rule is deployed or not. If there’s a deployment failure, hover over the information icon to view the failure reason.

Last Updated

Specifies the date and time at which the rule was last updated.

The format is Day MMM DD YYYY HH:MM:SS Timezone.

The following table describes the action items, in the Actions menu drop-down list, that appear on the NAT Rules tab.

Action Item

Description

Create NAT Rule

Choose Create NAT Rule to add a NAT rule.

Delete NAT Rule

Select a mode from the table and choose Delete NAT Rule to delete the rule.

Import

Allows you to import NAT rules from a CSV file to Nexus Dashboard Fabric Controller.

Export

Allows you to export NAT rules from Nexus Dashboard Fabric Controller to a CSV file.

Deploy Selected NAT Rules

Select rules from the table and choose Deploy Selected NAT Rules to deploy selected rules to the switch.

Deploy All NAT Rules

Choose Deploy All NAT Rules to deploy all rules to the switch.

Undeploy Selected NAT Rules

Select rules from the table and choose Undeploy Selected NAT Rules to undeploy selected rules to the switch.

Undeploy All NAT Rules

Choose Undeploy All NAT Rules to undeploy all rules from the switch.

Redo All Failed NAT Rules

Choose Redo All Failed NAT Rules to deploy all failed rules.

Deployment History

Select a rule from the table and choose Deployment History to view the deployment history of the selected rule.

Deployment History shows the following fields.

  • Switch Name─Specifies the name of the switch that the rule was deployed to.

  • VRF-Specifies the VRF that the mapping belongs to.

  • Deployment Status─Displays the status of deployment. It shows if the deployment was Success or Failed.

  • Action─Specifies the action that is performed on the switch for that rule. Create implies that the rule has been deployed on the switch. Delete implies that the rule has been undeployed from the switch.

  • Deployment Date/Time─Specifies the date and time at which the rule was last updated. The format is Day MMM DD YYYY HH:MM:SS Timezone.

  • Failed Reason ─ Specifies why the rule wasn’t successfully deployed.

Adding NAT Rule

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Multicast NAT tab.

  4. Click the NAT Rules tab.

  5. Click Actions > Create NAT Rule to add a NAT rule.

    The Add NAT Rule window appears.

  6. In the Add NAT Rule window, specify the following information:

    Translation Type: Select one of the translation types:

    • Multicast-to-Multicast

    • Multicast-to-Unicast

    • Unicast-to-Multicast

      Mode: Select the NAT mode, that is, Ingress or Egress.

      This mode is not visible for Multicast-to-Unicast and Unicast-to-Multicast translation types.

      Selected Switch: Specifies the switch name. This field is read-only, and it’s based on the switch selected in the NAT Rules tab.

      VRF: Select the VRF for the NAT rule. By default, it’s the default VRF.

      Pre-Translation Group/Unicast IP: Specifies the multicast or unicast group before NAT.

      Post-Translation Group: Specifies the multicast or unicast group after NAT.

      Group Mask: Specifies the mask value for the NAT rule. By default, it’s 32.

      Pre-Translation Source: Specifies the source IP address before NAT.

      Post-Translation Source: Specifies the source IP address after NAT.

      note.svg

      The Post-Translation Source IP needs to be the secondary IP address on the loopback interface to make sure RPF check won’t fail. However, the switch maintains separate records for Pre- and Post- NAT records, and NDFC merges unicast-multicast pre-post entries as single flow.


      Source Mask: Specifies the source mask value for the NAT rule. By default, it’s 32.

      Post-Translation Source Port: Source Port is 0 by default. The value 0 means no translation.

      Post-Translation Destination Port: Destination Port is 0 by default. The value 0 means no translation.

    Static Oif: This field is not visible for Ingress mode. In Egress mode, this field displays Egress Interfaces defined in the Recirc Mappings screen. The field is empty if there are no mappings defined.

  7. Click Save & Deploy to save the NAT rule and deploy it.

Deleting NAT Rule

  1. Choose LAN > Fabrics.

  2. Double-click a fabric name.

    The Fabric Overview window appears.

  3. Click the Multicast NAT tab.

  4. Click the NAT Rules tab.

  5. Select the NAT mode that you need to delete and click Actions > Delete NAT Rule to delete a NAT rule.

    If the NAT rule isn’t deployed or failed, you can skip this step.

  6. Click Confirm to delete the selected NAT rule.

RTP/EDI Flow Monitor

note.svg

This tab is only available on IPFM fabric when you have deployed IPFM on Nexus Dashboard Fabric Controller.


  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > RTP/EDI Flow Monitor.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > RTP/EDI Flow Monitor.

note.svg

This section is applicable for both the IPFM and Generic Multicast modes in Nexus Dashboard Fabric Controller.


Cisco Nexus Dashboard Fabric Controller provides a view of all the active RTP and EDI streams. It also lists out active flows that have RTP and EDI drops and historical records for the same. For active IPFM flow, Nexus Dashboard Fabric Controller provides RTP and EDI topology to pinpoint the loss in network.

note.svg

You need to enable telemetry in the switches to view RTP/EDI Flow Monitor. For more information, refer your respective platform documentation.


The description of the fields in these tabs are:

Field

Description

VRF

Specifies the name of the VRF.

Switch

Specifies the name of the switch.

Interface

Specifies the interface from which the flows are detected.

Source IP

Specifies the source IP address of the flow.

Source Port

Specifies the source port of the flow.

Destination IP

Specifies the destination IP address of the flow.

Destination Port

Specifies the destination port of the flow.

Receiver IPs

Specifies the receiver IPs which are connected directly to the given switch.

Bit Rate

Specifies the bit rate of the flow, in bps, kbps, mbps, gbps, or tbp.

Packet Count

Specifies the number of packets in the flow.

Packet Loss

Specifies the number of lost packets.

Loss Start

Specifies the time at which the packet loss started.

Loss End

Specifies the time at which the packet loss stopped.

Start Time

Specifies the time at which the flow started.

Protocol

Specifies the protocol that is being used for the flow.

You can click the Telemetry Switch Sync Status link to check whether the switches are in sync. The Telemetry Sync Status window displays the status of the switches in the Sync Status field and the last time that the sync occurred in the Last Sync Time field.

The RTP/EDI Flow monitor window has the following tabs:

  • Active Flows

  • Packet Drop

  • Drop History

Active Flows

The Active Flows tab displays the current active flows. You can also view these flows by navigating to Flows > Flow Status. You can click a switch link to view the end-to-end flow topology.

Flow Topology

The flow topology is displayed for the active flows that are displayed in the Flow Status window. For more information about multicast NAT visualization, see Flow Status.

From Cisco NDFC Release 12.1.2e, the flow topology for the active flows is displayed in the Active Flows tab.

Click a switch link to display the end-to-end flow topology.

The flow topology displays the direction of the flows. The arrows in the icon indicate the direction of the flow from the sender to the receiver. The IP addresses suffixed with (S) and ® indicate the sender and receiver host respectively. If there are multiple receivers for a given flow, you can choose a receiver from the Select Receiver drop-down list.

The switches experiencing packet drops are circled in red.

Hover your cursor over a switch to display the following details:

  • Name

  • IP address

  • Model

  • Packet loss, if any

Click the file icon next to the links between the switches to view the interface counters errors for the interfaces connecting the two switches.

When you click the file icon, the show interface <interface name> counters errors command is run for the interface where the flow is participating between these switches, and the results are displayed in a pop-in.

Packet Drop

The Packet Drop tab shows the packet drops for active flows.

Drop History

When active RTP packet drop is not observed, records from the Packet Drop tab are moved to the Drop History tab. By default, the RTP drop history is maintained for 7 days. You can customize this setting by entering the required value in the IPFM history retention days field in Settings > Server Settings > IPFM and saving it.

note.svg

The Drop History tab displays only the last 100,000 records at the maximum.


Global Config

note.svg

This tab is only available on IPFM fabrics when you have deployed IPFM on Nexus Dashboard Fabric Controller. However, the IPFM fabric with generic multicast fabric technology is an exception (as the IPFM VRF created here is used for defining host/flow aliases for both IPFM and Generic Multicast Fabric).


  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Global Config.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Global Config.

Nexus Dashboard Fabric Controller allows two major operations.

  • Monitor the network.

  • Configure host and flow policies.

Nexus Dashboard Fabric Controller monitors the Flow Status, Discovered Host, Applied Host Policies, and other operations using Telemetry. For any operations triggered by the switch and received through telemetry (for example, Flow Established), Nexus Dashboard Fabric Controller periodically checks for new events and generate appropriate notification.

If pmn.deploy-on-import-reload.enabled server property is set to true during a switch reload, when Nexus Dashboard Fabric Controller receives switch coldStartSNMPtrap, it deploys Global Config, and Host and Flow policies that are showing 'Deployment Status=Successes' to the switch automatically. Deploy the switch telemetry and SNMP configuration can be deployed on demand by using Nexus Dashboard Fabric Controller packaged pmn_telemetry_snmp CLI template available in Templates.

Navigate to Global Config to set or modify Switch Global configuration and VRFs.

When you install Nexus Dashboard Fabric Controller with IPFM Deployment, you can deploy policies, the unicast bandwidth, Any Source Multicast (ASM) range, and VRFs using Global Config.

After you deploy the Nexus Dashboard Fabric Controller with IPFM, configure the bandwidth and ASM. The remaining percentage of the bandwidth is utilized by the multicast traffic. Nexus Dashboard Fabric Controller acts like a Master Controller, and deploy the bandwidth and ASM configurations to all the switches in the fabric.

As Cisco Nexus Dashboard Fabric Controller uses Telemetry to fetch data from the Fabric, the flow status and Kafka notifications may not reflect the current state in real time. It periodically checks new events and generates appropriate notification. For more information, refer to the Kafka Notifications for Cisco Nexus Dashboard Fabric Controller, Release 12.0.1a.

This section contains the following:

Switch Global Config

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Global Config > Switch Global Config.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Global Config > Switch Global Config.

Navigate to Switch Global Config to configure the global parameters.

note.svg

A user with the network operator role in Nexus Dashboard Fabric Controller cannot save, deploy, undeploy, add or delete ASM, or edit the unicast bandwidth reservation percentage.


After you configure the Unicast Bandwidth Reservation and ASM range, you can perform the following operations to deploy these configurations to the switches.

After deploying the global configurations, configure the WAN for each switch in your network.

Table 31. Switch Global Config Table Fields and Description

Field

Description

VRF

Specifies the name of the VRF. This VRF is used to associate IPFM Host/Flow policies as well as Host/Flow aliases for both IPFM and Generic Multicast fabrics.

Unicast Bandwidth Reservation %

Displays a numeric value that indicates the unicast bandwidth configuration percentage, and the status specifies if the bandwidth deployment was success, or failed or not deployed.

You can configure the server to allot a dedicated percentage of bandwidth to unicast traffic. The remaining percentage is automatically reserved for multicast traffic.

Click the numerical value link to view the details of the deployment history for the Unicast Bandwidth for the selected VRF and switch in the Deployment History pane. For more information, see !!!Dita2Adoc_MissingReference:!!!.

Click the Failed or Success link to view the details of the deployment status for the Unicast Bandwidth for the selected VRF and switch in the Deployment Status pane. For more information, see !!!Dita2Adoc_MissingReference:!!!.

Reserve Bandwidth to Receiver Only

Bandwidth reservation status specifies if the bandwidth deployment was success, or failed or not deployed.

The Enabled status indicates that the ASM traffic is pushed to the spine only if there is a receiver. This feature is applicable for switches with the Cisco NX-OS Release 9.3(5) and later.

Click the Enabled link to view the details of the deployment history for the Reserve Bandwidth for the selected VRF and switch in the Deployment History pane. For more information, see !!!Dita2Adoc_MissingReference:!!!.

Click the Failed link to view the details of the deployment status for the Reserve Bandwidth for the selected VRF and switch in the Deployment Status pane. For more information, see !!!Dita2Adoc_MissingReference:!!!.

ASM/MASK

Displays the number of Any Source Multicast (ASM) groups enabled for the selected VRF and the status indicates whether the ASM and Mask configuration was deployed successfully, or failed or not deployed.

The ASM is a PIM tree building mode that uses shared trees to discover new sources and receivers as well as source trees to form shortest paths from receivers to sources. ASM provides discovery of multicast sources.

The IP address and subnet mask in the ASM/MASK field define the multicast source.

The ASM range is configured by specifying the IP address and the subnet mask.

Click the numerical value link to view the details of the deployment history for the ASM/mask for the selected VRF and switch in the Deployment History pane. For more information, see !!!Dita2Adoc_MissingReference:!!!.

Click the Failed link to view the details of the deployment status for the ASM/mask for the selected VRF and switch in the Deployment Status pane. For more information, see !!!Dita2Adoc_MissingReference:!!!.

Click the table header to sort the entries in alphabetical order of that parameter.

The following table describes the action items, in the Actions drop-down list, that appears in the Switch Global Config window.

Table 32. Switch Global Config Actions and Description

Action Item

Description

Edit NBM VRF Config

Allows you to edit the NBM VRF configuration.To perform an edit, choose this option. The Edit NBM VRF Config window opens. Edit the required values and click Deploy.

Undeploy All

Undeploys ASM, unicast bandwidth, and reserved bandwidth configuration to all switches.

Undeploy Unicast BW

Undeploys only unicast bandwidth configuration.

Undeploy Reserve BW

Undeploys only the reserve bandwidth configuration.

Undeploy ASM/Mask

Undeploys only the ASM configuration.

Redo All Failed

Redeploys the selected failed configurations.

Deployment History

The following table describes the fields that appear on the Deployment History.

Table 33. Deployment History Field and Description

Field

Description

Type

Specifies whether the type is Unicast Bandwidth Reservation %, Reserve Bandwidth to Receiver Only, or ASM/MASK.

VRF

Specifies the name of the VRF.

Switch Name

Specifies the switch name in the fabric on which the configuration was deployed.

Deployment Status

Displays the status of deployment. It shows if the deployment was Success or Failed along with the reason why the deployment failed.

Action

Specifies the action that is performed on the switch, such as Create or Delete.

Deployment Date/Time

Displays the date and time when the deployment was initialized.

Deployment Status

The following table describes the fields that appear on the Deployment Status.

Table 34. Deployment Status Field and Description

Field

Description

Type

Specifies whether the type is Unicast Bandwidth Reservation %, Reserve Bandwidth to Receiver Only, or ASM/MASK.

VRF

Specifies the name of the VRF.

Switch Name

Specifies the switch name in the fabric on which the configuration was deployed.

IP Address

Specifies the IP address of the switch.

Deployment Status

Displays the status of deployment. It shows if the deployment was Success or Failed along with the reason why the VRF deployment failed.

Action

Specifies the action that is performed on the switch, for example, Create.

Deployment Date/Time

Displays the date and time when the deployment was initialized.

IPFM VRF

  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > Global Config > IPFM VRF.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > Global Config > IPFM VRF.

From Cisco NDFC Release 12.1.2e, IPFM VRF tab is included under the Fabric Overview window. Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > IPFM VRF.

Use the IPFM VRF window to create, edit, delete, and redeploy IPFM VRFs. You can view the deployment status and history of each VRF.

From Cisco NDFC Release 12.1.2e, you can configure and monitor both NBM active and passive VRFs. In NBM passive mode, NDFC will be involved only in the monitoring of IPFM fabric and not configuration except in setting up VRF mode as NBM passive. Perform the following steps to change the NBM mode:

  • Click Actions > Create VRF.

  • On the Create VRF window, enter the name of the VRF. Choose Active or Passive and click Save & Deploy.

note.svg

You cannot edit the existing VRF to change the NBM mode. You must delete and re-create VRF to change the NBM mode from active to passive or conversely.
If fabric is set to monitor mode, changing VRF is not applicable as this is fabric level configuration and not VRF configuration.


You are not allowed to create IPFM VRF when none of the switches are imported to NDFC. Import or add switch to the fabric to create IPFM VRF.

Discovery status is updated at regular interval by a background process. NBM configuration can be deployed even if the switch is in an unreachable state. After periodic discovery, the status of switches are updated appropriately.

Table 35. IPFM VRF Table Fields and Description

Field

Description

Name

Specifies the name of the VRF.

Mode

Specifies the type of mode (Active or Passive) of the VRF.

Deployment Status

Specifies whether the VRF deployment is successful, failed, or the VRF is not deployed. For default VRFs, the deployment status is displayed as Not Applicable. Click the Failed status to view more information about the Switch Global Config.

Deployment History

Specifies the deployment history of the VRF. For default VRFs, the deployment history is displayed as Not Applicable. Click View in Deployment History to view more information about the Deployment History.

Description

Specifies the description of the VRF.

Click the table header to sort the entries in alphabetical order of that parameter.

The following table describes the action items, in the Actions drop-down list that appears in the IPFM VRF horizontal tab on the Global Config tab in the Fabric Overview window.

Table 36. IPFM VRF Actions and Description

Action Item

Description

Create VRF

Allows you to create a new VRF.

To create a VRF, choose Create VRF from the Action drop-down list of the IPFM VRF horizontal tab on the Global Config tab in the Fabric Overview window. In the Create VRF window, enter the VRF name and description, choose Active or Passive mode and click Save & Deploy to retain the changes and deploy or click Cancel to discard the changes.

note.svg

When you create an active nondefault VRF, although the default host and flow policies are automatically created for that VRF, you must manually deploy the policies to the switches in the fabric. When VRF is set to passive, then flow policies are not created. For more information about deploying the policies manually, see Host Policies and Flow Policies.


Edit VRF

Allows you to edit a selected VRF.

To edit a VRF, select the check box next to the VRF that you want to edit and choose Edit VRF. In the Edit VRF*window, you can edit only the description and click *Save to retain the changes or click Cancel to discard the changes.

Delete VRF

Allows you to delete one or more VRFs, which deletes the data from the database and cancels the deployment on the switch.

To delete a VRF, select the check box next to the VRF that you want to delete and choose Delete VRF. You can select multiple VRF entries and delete them at the same instance.

Redeploy

Allows you to select and redeploy the VRFs with failed status.

To redeploy a VRF to the switch, select the check box next to the VRF that you want to deploy again and choose Redeploy. You can select multiple VRF entries and redeploy them at the same instance.

Deployment History

The following table describes the fields that appear in the Deployment History pane.

Table 37. Deployment History Field and Description

Field

Description

Type

Specifies the type of VRF.

VRF

Specifies the name of the VRF.

Switch Name

Specifies the switch on which the VRF is deployed.

Deployment Status

Displays the status of the deployment. It shows if the deployment was a Success, Failed along with the reason why the VRF deployment failed, or Not Applicable.

Action

Specifies the action that is performed on the switch, such as Create or Delete.

Deployment Date/Time

Displays the date and time when the deployment was initialized.

Deployment Status

The following table describes the fields that appear in the Deployment Status pane.

Table 38. Deployment Status Field and Description

Field

Description

Type

Specifies the type of VRF.

VRF

Specifies the name of the VRF.

Switch Name

Specifies the switch on which the VRF is deployed.

IP Address

Specifies the IP address of the switch.

Deployment Status

Displays the status of the deployment. It shows if the deployment was a Success or Failed along with the reason why the deployment failed.

Action

Specifies the action that is performed on the switch, for example, Create.

Deployment Date/Time

Displays the date and time when the deployment was initialized.

VRF (Generic Multicast)

note.svg

This tab is only available on IPFM fabric when you have deployed IPFM on Nexus Dashboard Fabric Controller and when the fabric technology is generic multicast.


  • Choose LAN > Fabrics. Click on a fabric to open the Fabric slide-in pane. Click the Launch icon. Choose Fabric Overview > VRF.

  • Choose LAN > Fabrics. Double-click on a fabric to open Fabric Overview > VRF.

Use the VRF window to create, edit, and delete VRFs.

Table 39. VRF Table Fields and Description

Field

Description

Name

Specifies the name of the VRF.

Deployment Status

For generic multicast VRFs, the deployment status is displayed as Not Applicable.

Deployment History

For generic multicast VRFs, the deployment status is displayed as Not Applicable.

Description

Specifies the description of the VRF.

Click the table header to sort the entries in alphabetical order of that parameter.

The following table describes the action items, in the Actions drop-down list, that appears in the VRF window.

Table 40. VRF Actions and Description

Action Item

Description

Create VRF

Allows you to create a new VRF.To create a VRF, choose Create VRF from the Action drop-down list on the VRF tab in the Fabric Overview window. In the Add VRF window, enter the VRF name and description, and click Save to retain the changes or click Cancel to discard the changes.

Edit VRF

Allows you to edit a selected VRF.To edit a VRF, select the check box next to the VRF that you want to edit and choose Edit VRF. In the Edit VRF window, you can edit only the description and click Save to retain the changes or click Cancel to discard the changes.

Delete VRF

Allows you to delete a selected VRF.To delete a VRF, select the check box next to the VRF that you want to delete and choose Delete VRF. You can select multiple VRF entries and delete them at the same instance.

Virtual Infrastructure

The following table describes the fields and description on the window.

Field

Description

VM Name

Specifies the name of the Kubernetes pod.

Compute Name

Displays the IP address of the Kubernetes pod.

Fabric Name

Specifies the phase (state) of the pod.

IP Address

Specifies the reason.

MAC Address

Specifies the applications of the pod.

Physical NIC

Specifies the namespace of the pod.

Port Channel

Specifies the node name of the pod.

Switch Interface

Specifies the switch interface connected to pod.

Switch Name

Specifies the name of the switch.

Switch IP

Specifies the IP address of the switch.

VLAN

Specifies the VLAN.

Locked

Specifies the whether the cluster is in locked state.

Power State

Specifies whether the openstack cluster power state.

Network State

Specifies whether the openstack cluster network state.

State

Specifies the state of openstack cluster.

THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.

The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS" WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.

IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

Any Internet Protocol (IP) addresses and phone numbers used in this document are not intended to be actual addresses and phone numbers. Any examples, command display output, network topology diagrams, and other figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental.

The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product.

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this URL: http://www.cisco.com/go/trademarks. Third-party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1110R)

© 2017-2024 Cisco Systems, Inc. All rights reserved.