Revised December 14, 2006
December 12, 2006
NOTICE:
THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE OR WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY. YOUR USE OF THE INFORMATION ON THE FIELD NOTICE OR MATERIALS LINKED FROM THE FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.
Products Affected
|
Product |
Comments |
|---|---|
|
C6000 - WS-SUP720 |
Version 5.2 or later are affected |
|
C6000 - WS-SUP720-3B |
Version 5.2 or later are affected |
|
C6000 - WS-SUP720-3B= |
Version 5.2 or later are affected |
|
C6000 - WS-SUP720-3BXL |
Version 5.2 or later are affected |
|
C6000 - WS-SUP720-3BXL= |
Version 5.2 or later are affected |
|
C6000 - WS-SUP720= |
Version 5.2 or later are affected |
|
C6503 - WS-C6503 |
|
|
C6506 - WS-C6506 |
|
|
C6509 - WS-C6509 |
|
|
C6509 - WS-C6509-NEB |
|
|
C6509 - WS-C6509-NEB-A |
|
|
C6513 - WS-C6513 |
|
|
7600 - CISCO7609 |
|
|
7600 - CISCO7603 |
|
|
7600 - CISCO7606 |
|
|
7600 - CISCO7613 |
|
|
7600 - WS-SUP720 |
Version 5.2 or later are affected |
|
7600 - WS-SUP720-3B |
Version 5.2 or later are affected |
|
7600 - WS-SUP720-3BXL |
Version 5.2 or later are affected |
|
7609 - OSR-7609-AC |
|
|
7609 - OSR-7609-DC |
|
|
12.2(18)SX - 12.2(18)SXE |
Versions up to 12.2(18)SXE6a are affected |
|
12.2(18)SX - 12.2(18)SXD |
Versions up to 12.2(18)SXD7a are affected |
|
12.2(18)SX - 12.2(18)SXF |
Versions up to 12.2(18)SXF6 are affected |
|
12.2(33SR - 12.2(33)SR |
Version up to 12.2(18)33SRA01 are affected |
Problem Description
The Supervisor Engine 720 may restart after a second Supervisor Engine 720 is inserted in the chassis. The Supervisor Engine crash occurs if the Ethernet Out Band Channel (EOBC) gets jammed during the online insertion process.
-
This problem occurs in 6500 non-E and 7600 series chassis running affected Cisco IOS software versions.
-
This problem occurs when the hardware version of both Supervisor Engines is 5.2 or later.
-
Initially, the problem may not occur. However, once the problem occurs, it may recur during all subsequent online insertions.
Note:
To identify the hardware version, refer to How to Identify Hardware Levels section.
Background
An EOBC jam is created by the online insertion (OIR) of standby Supervisor Engine 720 of hardware revision 5.2 when the active Supervisor Engine 720 is also of hardware revision 5.2, in a non-E chassis.
Note:
For affected IOS versions, refer to Cisco IOS Versions Affected section.
Problem Symptoms
Inserting a second Supervisor Engine 720 in a Non-E chassis may cause the active supervisor to crash with EOBC JAM error. The following error message will be displayed.
Error Message:
Router> 00:20:27: %SYS-SP-3-LOGGER_FLUSHING: System pausing to ensure console debugging output. 00:20:27: %EOBC-SP-2-EOBC_JAM: EOBC channel is jammed. Attempting to diagnose the source of the problem and recover if possible. 00:20:27: %OIR-SP-6-CONSOLE: Changing console ownership to switch processor
Workaround/Solution
Upgrade IOS software to the following IOS versions accordingly:
-
12.2(18)SXD07a or later versions.
-
12.2(18)SXE06a or later versions.
-
12.2(18)SXF06 or later versions.
-
12.2(33)SRA01 or later versions.
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.
|
DDTS |
Description |
|---|---|
|
CSCse73539 (registered customers only) |
c7600 - crash of active sup720 after inserting a second one |
Cisco IOS Versions Affected
All 12.2(18)SXD Cisco IOS Versions up to, but not including 12.2(18)SXD07a
All 12.2(18)SXE Cisco IOS Versions up to, but not including 12.2(18)SXE06a
All 12.2(18)SXF Cisco IOS Versions up to, but not including 12.2(18)SXF06
All 12.2(33)SR Cisco IOS Versions up to, but not including 12.2(33)SRA01
How To Identify Hardware Levels
You may query the hardware version of the Supervisor Engine 720 by using the show mod exec CLI command.
Example:
Router>sh mod Mod Ports Card Type Model Serial No. --- ----- -------------------------------------- ------------------ ----------- 6 2 Supervisor Engine 720 (Active) WS-SUP720-3B SAL1013H66F Mod MAC addresses Hw Fw Sw Status --- ---------------------------------- ------ ------------ ------------ ------- 6 0013.c43a.bcd8 to 0013.c43a.bcdb 5.2 8.4(2) 12.2(18)SXF4 Ok Mod Sub-Module Model Serial Hw Status ---- --------------------------- ------------------ ----------- ------- ------- 6 Policy Feature Card 3 WS-F6K-PFC3B SAL1013H2W2 2.3 Ok 6 MSFC3 Daughterboard WS-SUP720 SAL1013H67Z 2.5 Ok Mod Online Diag Status ---- ------------------- 6 Pass
Revision History
|
Revision |
Date |
Comment |
|---|---|---|
|
1.1 |
14-DEC-2006 |
Updated the Problem Description section to clarify that both Supervisor Engines must be HW rev. 5.2 or later for the problem to occur. |
|
1.0 |
12-DEC-2006 |
Initial Public Release |
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.