Table Of Contents
Technical Specifications
Switch Specifications
Power Specifications for the Cisco MDS 9250i Switch
General Power Supply Specifications
AC Power Consumption
Connection Guidelines for AC-Powered Systems
SFP+ Transceiver Specifications
Cisco Fibre Channel SFP+ Transceivers
General Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
Environmental and Power Requirements for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.
General Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
Environmental and Power Requirements for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP+ Transceivers
Technical Specifications
This appendix provides technical specifications and includes the following sections:
•Switch Specifications
•Power Specifications for the Cisco MDS 9250i Switch
•SFP+ Transceiver Specifications
Note Specifications for cables and connectors are provided in "Cable and Port Specifications."
Switch Specifications
The Cisco MDS 9250i switch supports hot-swappable fan modules that provide 200 linear feet per minute (LFM) per minute of airflow with 300 W of power dissipation.
Table B-1 lists the environmental specifications for the Cisco MDS 9250i switch.
Table B-1 Environmental Specifications for the Cisco MDS 9250i switch
Description
|
Specification
|
Temperature, certified for operation
|
32 to 104°F (0 to 40°C)
|
Temperature, ambient nonoperating and storage
|
-40 to 158°F (-40 to 70°C)
|
Humidity (RH), ambient (noncondensing) operating
|
10 to 90%
|
Humidity (RH), ambient (noncondensing) nonoperating and storage
|
5 to 95%
|
Altitude, certified for operation
|
-197 to 6500 ft (-60 to 2000 m)
|
Altitude, designed and tested for operation
|
-200 to 10000 ft (-60 to 3000 m)
|
Table B-2 lists the physical specifications for the Cisco MDS 9250i switch.
Table B-2 Physical Specifications for the Cisco MDS 9250i switch
Description
|
Specification
|
Dimensions (HxWxD)
|
3.84 x 17.22 x 21.4 in. (9.75 x 43.74 x 54.36 cm); 2RU
|
Weight
|
22.4 lb (10.2 kg)
Chassis configured with three power supply modules and two fan modules
|
Front-to-back airflow
|
278 LFM
|
Power Specifications for the Cisco MDS 9250i Switch
This section includes the following topics:
•General Power Supply Specifications
•Power Supply Requirements and Heat Dissipation Specifications, page B-3
•AC Power Consumption
•Connection Guidelines for AC-Powered Systems
General Power Supply Specifications
Table B-3 lists the specifications for the Cisco MDS 9250i switch AC input power supply.
Table B-3 Cisco MDS 9250i switch AC Input Power Supply Specifications
AC Input Power Supply
|
Specification
|
AC input voltage
|
Minimum = 85 VAC
Nominal = 100 to 240 VAC
Maximum = 264 VAC
|
AC input current rating (maximum)
|
4.7 A at 85 VAC 3.6 A at 110 VAC 1.8 A at 220 VAC
|
AC input frequency
|
Minimum = 47 Hz
Nominal = 50 to 60 Hz
Maximum = 63 Hz
|
Power supply output capacity
|
300 W
|
Power supply output voltage
|
12 V +/- 6% up to 25 A
|
Output holdup time
|
20ms when input > 100 VAC
|
AC Power Consumption
Table B-5 shows the typical AC power consumption for the Cisco MDS 9250i Multiservice switch.
Table B-4 Typical AC Power Consumption for the Cisco MDS 9250i Multiservice Switch
|
AC Volt (V)
|
AC Power (W)
|
Typical Value 1
|
220
|
319
|
110
|
333
|
Worst Value 2
|
220
|
406
|
11
|
425
|
Connection Guidelines for AC-Powered Systems
For connecting the Cisco MDS 9250i switch switch AC power supplies to the site power source, follow these basic guidelines:
•Each power supply should have its own dedicated branch circuit.
•For international, circuits should be sized according to local and national codes.
The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment.
SFP+ Transceiver Specifications
The Cisco MDS 9250i switch is compatible with SFP+ transceivers and cables that have LC connectors. The wavelength of each transceiver must match the transceiver on the other end of the cable, and the cable must not exceed the stipulated cable length for reliable communications.
Cisco SFP+ transceivers provide the uplink interfaces, laser transmit (TX) and laser receive (RX), and support 850 to 1610 nm nominal wavelengths, depending upon the transceiver.
Use only Cisco SFP+ transceivers on the Cisco MDS 9250i switches. Each Cisco SFP+ transceiver is encoded with model information that enables the switch to verify that the SFP+ transceiver meets the requirements for the switch.
This section provides the following topics:
•Cisco Fibre Channel SFP+ Transceivers
Cisco Fibre Channel SFP+ Transceivers
Table B-5 lists the Cisco 1- Gbps, 8-Gbps, 10-Gbps, and 16-Gbps SFP+ Fibre Channel transceivers.
Table B-5 Cisco 8-Gbps and 16-Gbps SFP+ Fibre Channel Transceivers
Transceiver Module Product Number
|
Description
|
Type
|
DS-SFP-FC16G-SW
|
4/8/16-Gbps Fibre Channel SW, SFP+, LC
|
Short wavelength
|
DS-SFP-FC16G-SW
|
4/8/16-Gbps Fibre Channel LW, SFP+, LC
|
Long wavelength
|
DS-SFP-FC8G-SW
|
2/4/8-Gbps Fibre Channel SW, SFP+, LC
|
Short wavelength
|
DS-SFP-FC8G-LW
|
2/4/8-Gbps Fibre Channel LW, SFP+, LC
|
Long wavelength
|
General Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
Table B-6 provides the general specifications for Cisco 16-Gbps Fibre Channel SFP+ transceivers.
Table B-6 General Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Wavelength (nanometer)
|
Fiber Type
|
Core Size (micon)
|
Baud Rate
(GBd)
|
Cable Distance
(meter)
|
DS-SFP-FC16G-SW
|
850
|
MMF
|
62.5
|
14025
|
150 m
|
DS-SFP-FC16G-LW
|
1310
|
SMF
|
G.652
|
14025
|
6.2 miles (10 km)
|
Environmental and Power Requirements for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
Table B-7 provides the power specification for the Cisco 16-Gbps Fibre Channel SFP+ transceivers.
Table B-7 Power Requirements Specification for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Average Transmit Power (dBm)
|
Average Receive Power (dBm)
|
Fiber Loss Budget (dBm)
|
Maximum
|
Minimum
|
Maximum
|
Minimum
|
|
|
|
DS-SFP-FC16G-SW
|
-1.3
|
-9 (4 Gbps) -8.2 (8 Gbps) -7.8 (16 Gbps)
|
0
|
-
|
12
|
12
|
12
|
DS-SFP-FC16G-LW
|
1.3
|
-9 (4 Gbps) -8.2 (8 Gbps) -7.8 (16 Gbps)
|
0
|
-
|
12
|
12
|
12
|
Table B-8 provides the environment specification for the Cisco 16-Gbps Fibre Channel SFP+ transceivers.
Table B-8 Environmental Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Operating
|
Storage
|
Maximum
|
Minimum
|
Maximum
|
Minimum
|
DS-SFP-FC16G-SW
|
40°C
|
0°C
|
85°C
|
-40°C
|
DS-SFP-FC16G-LW
|
40°C
|
0°C
|
85°C
|
-40°C
|
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.
General Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
Table B-9 provides the general specifications for Cisco 10-Gbps Fibre Channel SFP+ transceivers.
Table B-9 General Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Wavelength (nanometer)
|
Fiber Type
|
Core Size (micon)
|
Baud Rate
(GBd)
|
Cable Distance
(meter)
|
DS-SFP-FC10G-SW
|
850
|
MMF
|
62.5 (OM1)
|
10.518
|
33m (104 ft)
|
|
50 (OM3)
|
10.518
|
82m (269 ft)
|
50 (OM3)
|
10.518
|
300m (984 ft)
|
DS-SFP-FC10G-LW
|
1310
|
SMF
|
9.0
|
10.518
|
10 km (6.2 miles)
|
Environmental and Power Requirements for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
Table B-10 provides the power specification for the Cisco 10-Gbps Fibre Channel SFP+ transceivers.
Table B-10 Power Requirements Specification for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Average Transmit Power (dBm)
|
Average Receive Power (dBm)
|
Fiber Loss Budget (dBm)
|
Maximum
|
Minimum
|
Maximum
|
Minimum
|
|
DS-SFP-FC10G-SW
|
-1.3
|
-7.3
|
-1.0
|
-9.9
|
7.3
|
DS-SFP-FC10G-LW
|
0.5
|
-8.2
|
-1.0
|
-9.9
|
7.4
|
Table B-11 provides the environment specification for the Cisco 10-Gbps Fibre Channel SFP+ transceivers.
Table B-11 Environmental Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Operating
|
Storage
|
Maximum
|
Minimum
|
Maximum
|
Minimum
|
DS-SFP-FC10G-SW
|
40°C
|
0°C
|
85°C
|
-40°C
|
DS-SFP-FC10-LW
|
40°C
|
0°C
|
85°C
|
-40°C
|
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.
General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
Table B-12 provides the general specifications for Cisco Fibre Channel SFP+ transceivers.
Table B-12 General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Wavelength (nanometer)
|
Fiber Type
|
Core Size (micon)
|
Baud Rate
(GBd)
|
Cable Distance
(meter)
|
DS-SFP-FC8G-SW
|
850
|
MMF
|
62.5
|
8.5
|
150 m (492 ft)
|
DS-SFP-FC8G-LW
|
1310
|
SMF
|
9.0
|
8.5
|
6.2 miles (10 km)
|
Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
Table B-13 provides the power specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers.
Table B-13 Power Requirements Specification for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
SFP
|
Average Transmit Power (dBm)
|
Average Receive Power (dBm)
|
Fiber Loss Budget (dBm)
|
Maximum
|
Minimum
|
Maximum
|
Minimum
|
|
|
|
DS-SFP-FC8G-SW
|
-1.3
|
-10 (2 Gbps) -9 (4 Gbps) -8.2 (8 Gbps)
|
0
|
-
|
62.5 microns
|
50.0 microns [OM2]
|
50.0 microns [OM3]
|
|
|
|
|
|
2.10 (2 Gbps)
1.78 (4 Gbps)
1.58 (8 Gbps)
|
2.62 (2 Gbps)
2.06 (4 Gbps)
1.68 (8 Gbps)
|
3.31 (2 Gbps)
2.88 (4 Gbps)
2.04 (8 Gbps)
|
DS-SFP-FC8G-LW
|
-3 (2 Gbps)
-1 (4 Gbps)
+0.5 (8 Gbps)
|
-11.7 (2 Gbps)
-8.4 (4 Gbps)
-8.4 (8 Gbps)
|
-3 (2 Gbps)
-1 (4 Gbps)
+0.5 (8 Gbps)
|
-
|
7.8 (2 Gbps)
7.8 (4 Gbps)
6.4 (8 Gbps)
|
Table B-14 provides the environment specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers.
Table B-14 Environmental Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers
SFP+
|
Operating
|
Storage
|
Maximum
|
Minimum
|
Maximum
|
Minimum
|
DS-SFP-FC8G-SW
|
40°C
|
0°C
|
85°C
|
-40°C
|
DS-SFP-FC8G-LW
|
40°C
|
0°C
|
85°C
|
-40°C
|
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.
Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP+ Transceivers
Table B-15 provides the maximum environmental and electrical ratings for Cisco Fibre Channel SFP+ transceivers.
Table B-15 Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP+ Transceivers
|
Symbol
|
Min.
|
|
Unit
|
Notes
|
Storage temperature
|
TS
|
-40
|
85
|
°C
|
1
|
Case temperature
|
TC
|
0
|
70
|
°C
|
1, 2
|
Relative humidity
|
RH
|
5
|
95
|
%
|
1
|
For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.