Cisco MDS 9250i Multiservice Fabric Switch Hardware Installation Guide
Technical Specifications

Table Of Contents

Technical Specifications

Switch Specifications

Power Specifications for the Cisco MDS 9250i Switch

General Power Supply Specifications

AC Power Consumption

Connection Guidelines for AC-Powered Systems

SFP+ Transceiver Specifications

Cisco Fibre Channel SFP+ Transceivers

General Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers

Environmental and Power Requirements for Cisco 16-Gbps Fibre Channel SFP+ Transceivers

For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

General Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers

Environmental and Power Requirements for Cisco 10-Gbps Fibre Channel SFP+ Transceivers

General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers

Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers

Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP+ Transceivers


Technical Specifications


This appendix provides technical specifications and includes the following sections:

Switch Specifications

Power Specifications for the Cisco MDS 9250i Switch

SFP+ Transceiver Specifications


Note Specifications for cables and connectors are provided in "Cable and Port Specifications."


Switch Specifications

The Cisco MDS 9250i switch supports hot-swappable fan modules that provide 200 linear feet per minute (LFM) per minute of airflow with 300 W of power dissipation.

Table B-1 lists the environmental specifications for the Cisco MDS 9250i switch.

Table B-1 Environmental Specifications for the Cisco MDS 9250i switch

Description
Specification

Temperature, certified for operation

32 to 104°F (0 to 40°C)

Temperature, ambient nonoperating and storage

-40 to 158°F (-40 to 70°C)

Humidity (RH), ambient (noncondensing) operating

10 to 90%

Humidity (RH), ambient (noncondensing) nonoperating and storage

5 to 95%

Altitude, certified for operation

-197 to 6500 ft (-60 to 2000 m)

Altitude, designed and tested for operation

-200 to 10000 ft (-60 to 3000 m)


Table B-2 lists the physical specifications for the Cisco MDS 9250i switch.

Table B-2 Physical Specifications for the Cisco MDS 9250i switch 

Description
Specification

Dimensions (HxWxD)

3.84 x 17.22 x 21.4 in. (9.75 x 43.74 x 54.36 cm); 2RU

Weight

22.4 lb (10.2 kg)

Chassis configured with three power supply modules and two fan modules

Front-to-back airflow

278 LFM


Power Specifications for the Cisco MDS 9250i Switch

This section includes the following topics:

General Power Supply Specifications

Power Supply Requirements and Heat Dissipation Specifications, page B-3

AC Power Consumption

Connection Guidelines for AC-Powered Systems

General Power Supply Specifications

Table B-3 lists the specifications for the Cisco MDS 9250i switch AC input power supply.

Table B-3 Cisco MDS 9250i switch AC Input Power Supply Specifications

AC Input Power Supply
Specification

AC input voltage

Minimum = 85 VAC

Nominal = 100 to 240 VAC

Maximum = 264 VAC

AC input current rating (maximum)

4.7 A at 85 VAC
3.6 A at 110 VAC
1.8 A at 220 VAC

AC input frequency

Minimum = 47 Hz

Nominal = 50 to 60 Hz

Maximum = 63 Hz

Power supply output capacity

300 W

Power supply output voltage

12 V +/- 6% up to 25 A

Output holdup time

20ms when input > 100 VAC


AC Power Consumption

Table B-5 shows the typical AC power consumption for the Cisco MDS 9250i Multiservice switch.

Table B-4 Typical AC Power Consumption for the Cisco MDS 9250i Multiservice Switch  

 
AC Volt (V)
AC Power (W)

Typical Value 1

220

319

110

333

Worst Value 2

220

406

11

425


1Typical Value is at 25 C ambient temperature, 0% voltage margin, fully-populated with SFPs, and 50% traffic load.

2Worst Value is at 55C ambient temperature , 5% voltage margin, fully-populated with SFPs, and 100% traffic load.

Connection Guidelines for AC-Powered Systems

For connecting the Cisco MDS 9250i switch switch AC power supplies to the site power source, follow these basic guidelines:

Each power supply should have its own dedicated branch circuit.

For international, circuits should be sized according to local and national codes.

The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment.

SFP+ Transceiver Specifications

The Cisco MDS 9250i switch is compatible with SFP+ transceivers and cables that have LC connectors. The wavelength of each transceiver must match the transceiver on the other end of the cable, and the cable must not exceed the stipulated cable length for reliable communications.

Cisco SFP+ transceivers provide the uplink interfaces, laser transmit (TX) and laser receive (RX), and support 850 to 1610 nm nominal wavelengths, depending upon the transceiver.

Use only Cisco SFP+ transceivers on the Cisco MDS 9250i switches. Each Cisco SFP+ transceiver is encoded with model information that enables the switch to verify that the SFP+ transceiver meets the requirements for the switch.

This section provides the following topics:

Cisco Fibre Channel SFP+ Transceivers

Cisco Fibre Channel SFP+ Transceivers

Table B-5 lists the Cisco 1- Gbps, 8-Gbps, 10-Gbps, and 16-Gbps SFP+ Fibre Channel transceivers.

Table B-5 Cisco 8-Gbps and 16-Gbps SFP+ Fibre Channel Transceivers  

Transceiver Module
Product Number
Description
Type

DS-SFP-FC16G-SW

4/8/16-Gbps Fibre Channel SW, SFP+, LC

Short wavelength

DS-SFP-FC16G-SW

4/8/16-Gbps Fibre Channel LW, SFP+, LC

Long wavelength

DS-SFP-FC8G-SW

2/4/8-Gbps Fibre Channel SW, SFP+, LC

Short wavelength

DS-SFP-FC8G-LW

2/4/8-Gbps Fibre Channel LW, SFP+, LC

Long wavelength


General Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers

Table B-6 provides the general specifications for Cisco 16-Gbps Fibre Channel SFP+ transceivers.

Table B-6 General Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers

SFP+
Wavelength
(nanometer)
Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)

DS-SFP-FC16G-SW

850

MMF

62.5

14025

150 m

DS-SFP-FC16G-LW

1310

SMF

G.652

14025

6.2 miles (10 km)


Environmental and Power Requirements for Cisco 16-Gbps Fibre Channel SFP+ Transceivers

Table B-7 provides the power specification for the Cisco 16-Gbps Fibre Channel SFP+ transceivers.

Table B-7 Power Requirements Specification for Cisco 16-Gbps Fibre Channel SFP+ Transceivers 

SFP+
Average Transmit
Power (dBm)
Average Receive
Power (dBm)
Fiber Loss Budget (dBm)
Maximum
Minimum
Maximum
Minimum
     

DS-SFP-FC16G-SW

-1.3

-9 (4 Gbps)
-8.2 (8 Gbps)
-7.8 (16 Gbps)

0

-

12

12

12

DS-SFP-FC16G-LW

1.3

-9 (4 Gbps)
-8.2 (8 Gbps)
-7.8 (16 Gbps)

0

-

12

12

12


Table B-8 provides the environment specification for the Cisco 16-Gbps Fibre Channel SFP+ transceivers.

Table B-8 Environmental Specifications for Cisco 16-Gbps Fibre Channel SFP+ Transceivers

SFP+
Operating
Storage
Maximum
Minimum
Maximum
Minimum

DS-SFP-FC16G-SW

40°C

0°C

85°C

-40°C

DS-SFP-FC16G-LW

40°C

0°C

85°C

-40°C


For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

General Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers

Table B-9 provides the general specifications for Cisco 10-Gbps Fibre Channel SFP+ transceivers.

Table B-9 General Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers

SFP+
Wavelength
(nanometer)
Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)

DS-SFP-FC10G-SW

850

MMF

62.5 (OM1)

10.518

33m (104 ft)

 

50 (OM3)

10.518

82m (269 ft)

50 (OM3)

10.518

300m (984 ft)

DS-SFP-FC10G-LW

1310

SMF

9.0

10.518

10 km (6.2 miles)


Environmental and Power Requirements for Cisco 10-Gbps Fibre Channel SFP+ Transceivers

Table B-10 provides the power specification for the Cisco 10-Gbps Fibre Channel SFP+ transceivers.

Table B-10 Power Requirements Specification for Cisco 10-Gbps Fibre Channel SFP+ Transceivers 

SFP+
Average Transmit
Power (dBm)
Average Receive
Power (dBm)
Fiber Loss Budget (dBm)
Maximum
Minimum
Maximum
Minimum
 

DS-SFP-FC10G-SW

-1.3

-7.3

-1.0

-9.9

7.3

DS-SFP-FC10G-LW

0.5

-8.2

-1.0

-9.9

7.4


Table B-11 provides the environment specification for the Cisco 10-Gbps Fibre Channel SFP+ transceivers.

Table B-11 Environmental Specifications for Cisco 10-Gbps Fibre Channel SFP+ Transceivers

SFP+
Operating
Storage
Maximum
Minimum
Maximum
Minimum

DS-SFP-FC10G-SW

40°C

0°C

85°C

-40°C

DS-SFP-FC10-LW

40°C

0°C

85°C

-40°C


For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers

Table B-12 provides the general specifications for Cisco Fibre Channel SFP+ transceivers.

Table B-12 General Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers

SFP+
Wavelength
(nanometer)
Fiber Type
Core Size
(micon)
Baud Rate
(GBd)
Cable Distance
(meter)

DS-SFP-FC8G-SW

850

MMF

62.5

8.5

150 m (492 ft)

DS-SFP-FC8G-LW

1310

SMF

9.0

8.5

6.2 miles (10 km)


Environmental and Power Requirements for Cisco 8-Gbps Fibre Channel SFP+ Transceivers

Table B-13 provides the power specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers.

Table B-13 Power Requirements Specification for Cisco 8-Gbps Fibre Channel SFP+ Transceivers 

SFP
Average Transmit
Power (dBm)
Average Receive
Power (dBm)
Fiber Loss Budget (dBm)
Maximum
Minimum
Maximum
Minimum
     

DS-SFP-FC8G-SW

-1.3

-10 (2 Gbps)
-9 (4 Gbps)
-8.2 (8 Gbps)

0

-

62.5 microns

50.0 microns [OM2]

50.0 microns [OM3]

         

2.10 (2 Gbps)

1.78 (4 Gbps)

1.58 (8 Gbps)

2.62 (2 Gbps)

2.06 (4 Gbps)

1.68 (8 Gbps)

3.31 (2 Gbps)

2.88 (4 Gbps)

2.04 (8 Gbps)

DS-SFP-FC8G-LW

-3 (2 Gbps)

-1 (4 Gbps)

+0.5 (8 Gbps)

-11.7 (2 Gbps)

-8.4 (4 Gbps)

-8.4 (8 Gbps)

-3 (2 Gbps)

-1 (4 Gbps)

+0.5 (8 Gbps)

-

7.8 (2 Gbps)

7.8 (4 Gbps)

6.4 (8 Gbps)


Table B-14 provides the environment specification for the Cisco 8-Gbps Fibre Channel SFP+ transceivers.

Table B-14 Environmental Specifications for Cisco 8-Gbps Fibre Channel SFP+ Transceivers

SFP+
Operating
Storage
Maximum
Minimum
Maximum
Minimum

DS-SFP-FC8G-SW

40°C

0°C

85°C

-40°C

DS-SFP-FC8G-LW

40°C

0°C

85°C

-40°C


For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.

Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP+ Transceivers

Table B-15 provides the maximum environmental and electrical ratings for Cisco Fibre Channel SFP+ transceivers.

Table B-15 Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP+ Transceivers 

Parameter1
Symbol
Min.
Max.2
Unit
Notes

Storage temperature

TS

-40

85

°C

1

Case temperature

TC

0

70

°C

1, 2

Relative humidity

RH

5

95

%

1

1 Do not operate outside the recommended operating conditions. Device reliability may be affected and damage to the device may occur over an extended period of time.

2 Absolute maximum ratings are those values beyond which damage to the device may occur if these limits are exceeded for other than a short period of time.


For information about safety, regulatory, and standards compliance, refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family.