Cisco Desktop Virtualization Solutions with VMware Horizon View

VMware Virtual SAN with Cisco Unified Computing System Reference Architecture

  • Viewing Options

  • PDF (1.9 MB)
  • Feedback

August 2014

Contents

Introduction.................................................................................................................................................................................. 2

VMware Virtual SAN.............................................................................................................................................................. 3

Cisco Unified Computing System...................................................................................................................................... 5

VMware Virtual SAN with Cisco UCS Architecture........................................................................................................... 7

Cisco UCS Configuration..................................................................................................................................................... 8

VMware Virtual SAN Configuration.................................................................................................................................. 12

VMware Virtual SAN Availability and Manageability....................................................................................................... 14

Benchmarking VMware Virtual SAN on Cisco UCS....................................................................................................... 26

Cisco UCS with VMware Virtual SAN Ready Nodes....................................................................................................... 35

Conclusion................................................................................................................................................................................. 35

Appendix A: IO Meter Custom Configuration Files.......................................................................................................... 36

Appendix B: VMware Virtual SAN Requirements............................................................................................................ 46

Appendix C: Ruby vSphere Console and VMware VSAN Observer........................................................................... 47

Appendix D: Cisco Part Numbers....................................................................................................................................... 48

Resources................................................................................................................................................................................. 49

Acknowledgements................................................................................................................................................................ 49


Introduction

Virtualization helps alleviate the pressure on IT departments by allowing organizations to do more with less through higher asset utilization, rapid deployment of applications, and the capability to scale existing deployments with greater efficiency and speed.

Virtualization improves the efficiency and optimization of data center assets, and it provides significant advantages including:

   Consolidation: Server virtualization enables IT to provision and deploy multiple virtual machines rapidly from fewer physical servers. This capability helps reduce or eliminate underutilized server and storage hardware, software, and infrastructure.

   Operation agility: Virtualization supports dynamic IT environments that both respond to problems and anticipate increased demands with features such as automated virtual machine reconfiguration, flexible resource control, and automated migration.

   Business continuity: Virtualization provides business continuity and IT disaster recovery capabilities using geographically dispersed clustering, remote management, and features such as live backup to reduce potential data loss.

 

Virtualization also provides effective solutions that improve system manageability, reduce energy consumption, and increase the capacity of data center facilities, thereby lowering the total cost of ownership (TCO).

When storage workloads are virtualized, they function differently than storage workloads in the physical world:

   With virtual workloads, the relationship between applications and storage is N:1, rather than 1:1 as in a physical environment.

   Virtual workloads are more mobile than physical workloads, with capabilities such as VMware Storage vMotion providing the flexibility to move workloads within the data center as required.

   The I/O operations per second (IOPS) requirements for virtualized applications are more random than the requirements for applications hosted in a physical world, which are more sequential.

 

In addition, emerging application trends for cloud computing and mobility initiatives are scale-out in nature and requires the underlying storage solution to be built with specific constructs such as performance or scalability in mind.

These features, plus the emergence of flash-memory storage solutions, including all flash-memory arrays, hybrid flash memory, and server-side flash memory, have created opportunities for new storage architectures, providing customers with a great deal of choice.

VMware vSphere, residing as the first piece of software code between the underlying infrastructure and the virtualized applications, has the inherent knowledge of the application requirements from the underlying storage systems and a global view of the infrastructure resources available, allowing it to meet these requirements. This environment provides a unique opportunity for a hypervisor-converged storage solution such as VMware Virtual SAN.


Building VMware Virtual SAN as a hypervisor-converged solution on industry-leading data center infrastructure founded on the Cisco Unified Computing System (Cisco UCS®) and VMware vSphere platforms allows customers to continue to benefit the extensive history of collaboration and joint innovation in the virtualized data center between Cisco and VMware. This differentiated solution is designed to deliver a scalable virtual and physical architecture, providing superior manageability, security, performance, and cost savings.

This document provides a reference architecture for VMware Virtual SAN on Cisco UCS, including configuration details for building the joint solution, benchmark measurements, and manageability and availability aspects for operating a VMware Virtual SAN on Cisco UCS environment.

VMware Virtual SAN

VMware Virtual SAN is a hypervisor-converged storage solution that is fully integrated with VMware vSphere. VMware Virtual SAN combines storage and computing for virtual machines into a single device, with storage provided within the hypervisor, instead of using a storage virtual machine running alongside other virtual machines. VMware Virtual SAN aggregates locally attached disks in a VMware vSphere cluster to create a storage solution, also called a shared datastore, which can be rapidly provisioned from VMware vCenter during virtual machine provisioning operations.

VMware Virtual SAN is an object-based storage system that is designed to provide virtual machine–centric storage services and capabilities through a storage-based policy management (SPBM) platform. SPBM and virtual machine storage policies are solutions designed to simplify virtual machine storage placement decisions for VMware vSphere administrators.

VMware Virtual SAN is fully integrated with core VMware vSphere enterprise features such as VMware vSphere vMotion, High Availability (HA), and Distributed Resource Scheduler (DRS). Its goal is to provide both high availability and scale-out storage functions. It can also be considered in the context of quality of service (QoS) because virtual machine storage policies can be created to define the levels of performance and availability required on a per-virtual machine basis.

As shown in Figure 1, VMware Virtual SAN shared datastore is constructed with a minimum of three VMware ESXi hosts, each containing at least one disk group with at least one solid-state drive (SSD) and one magnetic drive, and up to seven magnetic drives per disk group and up to five disk groups per host. The VMware virtual machine files are stored on the magnetic drive, and the SSD handles read caching and write buffering. The disk group on each host is joined to a single network partition group, shared and controlled by the hosts.

Figure 1.      VMware Virtual SAN Cluster

 

The size and capacity of the VMware Virtual SAN shared datastore are dictated by the number of magnetic disks per disk group in a VMware vSphere host and by the number of VMware vSphere hosts in the cluster. VMware Virtual SAN is a scale-out solution in which more capacity and performance are obtained by adding more disks to a disk group, adding more disk groups to a host, and adding more hosts to the cluster.

With VMware Virtual SAN, SPBM plays a major role in the way in which administrators can use virtual machine storage policies to specify a set of required storage capabilities for a virtual machine, or more specifically, a set of requirements for the application running in the virtual machine.

The following VMware Virtual SAN datastore capabilities are surfaced up to vCenterVMware vCenter Server:

   Number of Failures to Tolerate

   Number of Disk Stripes per Object

   Flash Read Cache Reservation

   Object Space Reservation

   Force Provisioning

 

For more information about the capabilities and features of VMware Virtual SAN, please refer to [1].


Cisco Unified Computing System

Cisco UCS is the fastest growing next-generation data center computing solution that unifies computing, networking, management, virtualization, and storage access into a cohesive system. By converging data center silos into a single unified system, Cisco UCS increases business agility and improves business continuity, thereby lowering TCO and providing the following benefits:

   Less infrastructure and more intelligent servers: This unique architecture enables end-to-end server visibility, management, and control in both bare-metal and virtual environments and facilitates the move to cloud computing and IT-as-a-service (ITaaS) with fabric-based infrastructure.

   Consolidated resources with Cisco UCS servers: Cisco UCS servers allow dramatic reduction in the number of devices an organization must purchase, cable, configure, power, cool, and secure. Cisco UCS servers optimize virtualized environments across the entire system. Cisco servers can support traditional operating systems and application stacks in physical environments.

   Accelerated server deployment: The smart, programmable infrastructure of Cisco UCS simplifies and accelerates enterprise-class application and service deployment in bare-metal, virtualized, and cloud computing environments. With Cisco UCS unified model-based management, administrators can configure hundreds of servers as quickly as they can configure a single server.

   Simplified management: Cisco UCS offers simplified and open management with a large partner ecosystem using Cisco UCS Manager.

 

The unified management capabilities provided by Cisco UCS Manager, integrated into Cisco UCS, offer administrators flexibility and simplicity. Administrators can manage physical infrastructure similar to the way that they manage virtual infrastructure. Cisco UCS applies familiar, critical virtualization concepts such as templates, policies, and stateless computing to the physical infrastructure. The result is a model-based management system that simplifies and automates administration, accelerates deployment and scaling, and reduces the likelihood of configuration errors that can cause downtime and long troubleshooting efforts in physical network, computing, and storage infrastructure.

The system integrates a low-latency, lossless 10 Gigabit Ethernet unified network fabric with enterprise-class, x86-architecture servers. The system is an integrated, scalable, multichassis platform in which all resources participate in a unified management domain (Figure 2).

Figure 2.      Cisco Unified Computing System

 

The system helps reduce TCO by automating element-management tasks through the use of service profiles that enable just-in-time provisioning. Service profiles increase business agility by quickly aligning computing resources with rapidly changing business and workload requirements.

Cisco UCS C-Series Rack Servers

Cisco UCS C-Series Rack Servers are designed for both performance and expandability over a wide range of storage-intensive infrastructure workloads ranging from big data to collaboration.

Cisco UCS C-Series Rack Servers provide the following benefits:

   Form-factor-independent entry point into Cisco UCS

   Simplified and fast deployment of applications

   Extension of unified computing innovations and benefits to rack servers

   Increased customer choice with unique benefits in a familiar rack package

   Reduced TCO and increased business agility

 

Several Cisco UCS C-Series Rack Server models are available. Each model is optimized for particular types of deployments to address different workload challenges through a balance of processing, memory, I/O, and internal storage resources.

The Cisco UCS with VMware Virtual SAN solution architecture is built on Cisco UCS C240 M3 Rack Servers. The Cisco UCS C240 M3 is a high-density, enterprise-class, 2RU rack server designed for computing, I/O, storage, and memory-intensive standalone and virtualized applications. It offers these benefits:

   Suitable for nearly all storage-intensive, 2-socket applications

   Unique Cisco UCS Virtual Interface Card (VIC) 1225: 2 x 10 Gigabit Ethernet PCI Express (PCIe) cards that can support up to 256 PCIe virtual interfaces

   Exceptional building block and entry point for Cisco UCS

   Continual innovations from Cisco in server technology and at all levels of Cisco UCS

 

The Cisco UCS C240 M3 offers up to 768 GB of RAM, 24 drives, and four 1 Gigabit Ethernet LAN interfaces built into the motherboard to provide outstanding levels of internal memory and storage expandability along with exceptional performance.

The Cisco UCS C240 M3 supports:

   Up to two Intel® Xeon® processor E5-2600 or E5-2600 v2 CPUs

   Up to 768 GB of RAM with 24 DIMM slots

   12 Large Form-Factor (LFF) or 24 Small Form-Factor (SFF) SAS, SATA, or SSD drives for workloads demanding a large amount of internal storage

   5 PCIe Generation 3 (Gen 3) slots and four 1 Gigabit Ethernet LAN interfaces on the motherboard

   Trusted Platform Module (TPM) for authentication and tool-free access

 

VMware Virtual SAN with Cisco UCS Architecture

Figure 3 shows the VMware on Cisco UCS C240 M3 solution as built at the Cisco lab in San Jose, California.

Figure 3.      VMware Virtual SAN with Cisco UCS Environment Details

 

This detailed architecture for the Cisco UCS with VMware Virtual SAN solution consists of the components listed in Table 1.

Table 1.       Cisco UCS with VMware Virtual SAN Architecture

Component

Description

Cisco UCS

8 Cisco UCS C240 M3 Rack Servers (x86 servers), each with:

  2 Intel Xeon processor E5-2643 CPUs
  24 8-GB 1600-MHz DDR3 RDIMMs, PC3-12800, dual rank, 1.35V
  21 Seagate 1-TB SATA disks
  3 SAMSUNG 800-GB SAS SSDs
  1 LSI MegaRAID SAS 9271CV-8i controller
  1 Cisco UCS VIC 1225 CNA
  2 Cisco Flexible Flash (FlexFlash) cards

VMware software

  VMware vCenter 5.5 Update 1
  VMware ESXi 5.5 Update 1

Fabric interconnects

2 Cisco UCS 6248UP 48-Port Fabric Interconnects

 

Each host is configured with three disk groups, each composed of one 800-GB SSD and seven SATA disks. This configuration uses the maximum of 24 slots available on the Cisco UCS C240 M3 Rack Server. In this 8-node cluster, the 168 magnetic disks provide a total VMware Virtual SAN datastore capacity of 152.40 terabytes (TB), calculated as follows:

3 disk groups per host x 7 magnetic disks per disk group x 930 GB x 8 hosts = 152.57 TB of raw capacity
152.57 TB raw capacity – 1681 GB metadata overhead = 152.40 TB of usable raw capacity

In this architecture, the maximum number of disk groups per host is configured to showcase the maximum VMware Virtual SAN datastore capacity available on the Cisco UCS C240 M3 in an 8 node cluster. Customers should build the VMware Virtual SAN environment based on the VMware Virtual SAN Ready Nodes information as described in the section Cisco UCS and VMware Virtual SAN Ready Nodes.

For networking, Cisco Data Center Virtual Machine Fabric Extender (VM-FEX) on a VMware vSphere distributed switch is used with a dedicated VMkernel network interface card (NIC) used for VMware Virtual SAN control and data traffic. This dedicated VMkernel NIC is a VMware Virtual SAN requirement, and multicasting needs to be enabled for the VMware Virtual SAN Layer 2 network. In addition, two VMkernel ports are configured for management and VMware vMotion traffic.

Cisco UCS Configuration

In this configuration, VMware ESXi is booted from the on-board Cisco FlexFlash SD cards [2], as shown here.

Note:    In this lab, a single FlexFlash SD card was used; however, the recommended configuration is two Cisco FlexFlash SD cards in a RAID configuration to help ensure reliability through redundancy in a production environment.

 

The Cisco FlexFlash SD card configuration is performed through a local disk policy that is applied to the service profile, as shown here.

 

VMware Virtual SAN Storage Controller

VMware Virtual SAN supports storage controllers in two modes: pass-through mode and RAID0 mode. An important consideration when choosing a storage controller for VMware Virtual SAN is whether it supports pass-through mode, RAID0 mode, or both. For Cisco UCS, both types of controllers are supported, as listed in the VMware Virtual SAN Compatibility Guide [3].

As a best practice, use the LSI MegaRAID SAS 9271CV-8i controller (Cisco UCS-RAID-9271-AI). This controller achieves higher performance compared to other controllers because of its larger (1024) queue depth. Controllers with a queue depth of less than 256 are not supported with VMware Virtual SAN as discussed in the VMware knowledge base.


When VMware Virtual SAN is implemented with pass-through controllers, VMware Virtual SAN accesses the drives directly, and RAID configuration is not necessary. When VMware Virtual SAN is implemented with controllers that do not support pass-through mode, a virtual RAID 0 drive must be created for each physical HDD that VMware Virtual SAN will use. Follow these steps to configure virtual RAID 0 with the LSI 9271CV-81 controller:

1.     Download the LSI StorCLI software from the LSI website [4] and install it on the VMware ESXi server.

2.     Execute StorCLI commands from the VMware ESXi console or through SSH. Use this command to create virtual disks of type RAID 0 for each of the individual disks:

/storcli /c0 add vd type=RAID0 name=vd1 drives=<enclosure number>:1

3.     Configure VMware ESXi to mark SSDs because it cannot identify SSDs abstracted behind a RAID controller. Use the following command:

esxcli storage nmp satp rule add –-satp VMW_SATP_LOCAL –-device <devicename> --option="enable_local enable_ssd”

 

Service Profile Configuration

The main configurable parameters of a service profile are summarized in Table 2.

Table 2.       Service Profile Parameters

Parameter Type

Parameter

Description

Server hardware

 

UUID

Obtained from defined UUID pool

MAC addresses

Obtained from defined MAC address pool

Worldwide port name (WWPN) and worldwide node name (WWNN)

Obtained from defined WWPN and WWNN pools

Boot policy

Boot path and order

Disk policy

RAID configuration

Fabric

 

LAN

Virtual NICs  (vNICs), VLANs, and maximum transmission unit (MTU)

SAN

Virtual host bus adapters (vHBAs) and VSANs

Quality-of-service (QoS) policy

CoS for Ethernet uplink traffic

Operation

Firmware policy

Current and backup versions

BIOS policy

BIOS version and settings

Statistics policy

System data collection

Power-control policy

Blade server power allotment

 

For Cisco UCS service profiles for hosts in a VMware Virtual SAN cluster, you should configure the policies shown here. This configuration does not include all Cisco UCS service profile settings. The settings shown here are configurations that are specific to an implementation with VMware Virtual SAN.


BIOS Policy

The following screen shows the BIOS policy configured for the VMware Virtual SAN environment. It is aimed at achieving high performance.

 

The BIOS policy configuration includes:

   Processor

     Power technology = Custom

     Enhanced Intel Speedstep = Enabled

     Intel Turbo Boost = Enabled

     Processor power state C6 = Disabled

     Processor power state C1 enhanced = Disabled

     Energy performance = Performance

   Memory

     Low-voltage DDR mode = Performance mode

 

Boot Policy

The boot policy is created with a Secure Digital (SD) card as the preferred boot option after the local CD or DVD boot option.

vNIC Template

Two VMware Virtual SAN vNIC templates are configured: one each for Fabric A and Fabric B. Jumbo frames are enabled to improve throughput and CPU efficiency, and the MTU size is set to 9000.


The QoS policy is set with a priority level of Platinum to help ensure that the VMware Virtual SAN traffic receives the highest traffic classification levels. Within the QoS system class, the enabled options include:

   Class-of-service (CoS) value of 5

   Weight value of 10

   50 percent weight

   MTU value of 9000

   Multicast optimized

 

The network control policy is set to Cisco Discovery Protocol enabled.

The dynamic vNIC connection policy is applied with an adapter policy of VMware, as shown here.

 

VLANs

A dedicated VLAN is recomemnded for the VMware Virtual SAN VMkernel NIC, and multicast is requred within the Layer 2 domain. This setting is configured as part of the VLAN as a multicast policy with snooping enabled.

VMware Virtual SAN Configuration

VMware Virtual SAN is a VMware ESXi cluster-level feature that is configured using the VMware vSphere Web Client. The first step in enabling the VMware Virtual SAN feature is to select one of the two modes of disk group creation:

   Automatic: Enable VMware Virtual SAN to discover all the local disks on the hosts and automatically add the disks to the VMware Virtual SAN datastore.

   Manual: Manually select the disks to add to the VMware Virtual SAN shared datastore.

 


The creation of disk groups and the overall health of the disks can be verified in the Disk Management view for the cluster, shown here.

 

When virtual machines are provisioned on the VMware Virtual SAN datastore, the storage policies are applied through the Virtual Machine Creation Wizard, shown here.

 

These storage polices are tied to the storage requirements for each virtual machine.


The Virtual Machine Creation Wizard can be used to configure create new virtual machine storage policies by choosing Rules and Profiles and then VM Storage Policies. Virtual machine policies can be applied using the Manage VM Storage Policies tab by choosing Virtual Machine and then VM Storage Policies, as shown here.

 

These policies are used to provide different levels of availability and performance for virtual machines. You can and should use different policies for different types of virtual machines within the same cluster to meet application requirements.

Table 3 lists the virtual machine storage policy requirements in VMware Virtual SAN.

Table 3.       Virtual Machine Storage Policy Requirements

Policy

Definition

Default

Maximum

Number of disk stripes per object

Defines the number of magnetic disks across which each replica of a storage object is distributed

1

12

Flash-memory read-cache reservation

Defines the flash-memory capacity reserved as the read cache for the storage object

0%

100%

Number of failures to tolerate

Defines the number of host, disk, and network failures a storage object can tolerate; for n failures tolerated, n+1 copies of the object are created, and 2n+1 hosts of contributing storage are required

1

3 (in 8-host cluster)

Forced provisioning

Determines whether the object is provisioned, even if currently available resources do not meet the virtual machine storage policy requirements

Disabled

[Enabled]

Object-space reservation

Defines the percentage of the logical size of the storage object that needs to be reserved (thick provisioned) upon virtual machine provisioning (the remainder of the storage object is thin provisioned)

0%

100%

 

Default storage policies are recommended for Tier 2 and 3 workloads. After the VMware Virtual SAN policies and datastore are configured and the environment is operational, several availability and maintenance scenarios could arise. These VMware Virtual SAN availability and manageability details are described in the next section.

VMware Virtual SAN Availability and Manageability

VMware Virtual SAN is fully integrated with VMware vSphere advanced features, including as VMware vSphere vMotion, DRS, and High Availability, to provide the best level of availability for the virtualized environment.

For redundancy, VMware Virtual SAN uses the concept of distributed RAID, by which a VMware vSphere cluster can contend with the failure of a VMware vSphere host or a component within a host. For example, the cluster can contend with the failure of magnetic disks, flash-memory-based devices, and network interfaces while continuing to provide complete capabilities for all virtual machines.


In addition, availability is defined on a per–virtual machine basis through the use of virtual machine storage policies. Through the use of virtual machine storage policies along with VMware Virtual SAN distributed RAID architecture, virtual machines and copies of their contents are distributed across multiple VMware vSphere hosts in the cluster. In the event of a failure, a failed node does not necessarily need to migrate data to a surviving host in the cluster.

The VMware Virtual SAN data store is based on object-oriented storage. In this approach, a virtual machine on the VMware Virtual SAN is made up of these VMware Virtual SAN objects:

   The virtual machine home, or namespace, directory

   A swap object (if the virtual machine is powered on)

   Virtual disks or virtual machine disks (VMDKs)

   Delta disks created for snapshots (each delta disk is an object)

 

The virtual machine namespace directory holds all virtual machine files (.vmx files, log files, etc.), excluding VMDKs, delta disks, and swap files, all of which are maintained as separate objects.

This approach is important to understand because it determines the way that objects and components are built and distributed in VMware Virtual SAN. For instance, there are soft limitations, and exceeding those limitations can affect performance.

In addition, witnesses are deployed to arbitrate between the remaining copies of data should a failure occur within the VMware Virtual SAN cluster. The witness component helps ensure that no split-brain scenarios occur.

Witness deployment is not predicated on any failures-to-tolerate (FTT) or stripe-width policy settings. Rather, witness components are defined as primary, secondary, and tiebreaker and are deployed based on the rules defined:

   Primary witnesses: Primary witnesses require at least (2 x FTT) + 1 nodes in a cluster to tolerate the FTT number of node and disk failures. If the configuration does not have the required number of nodes after all the data components have been placed, the primary witnesses are placed on exclusive nodes until the configuration has (2 x FTT) + 1 nodes.

   Secondary witnesses: Secondary witnesses are created to help ensure that each node has equal voting power toward a quorum. This capability is important because each node failure needs to affect the quorum equally. Secondary witnesses are added to allow each node to receive an equal number of components, including the nodes that hold only primary witnesses. The total count of data components plus witnesses on each node is equalized in this step.

   Tiebreaker witnesses: After primary witnesses and secondary witnesses have been added, if the configuration has an even number of total components (data and witnesses), then one tiebreaker witness is added to make the total component count an odd number.

 

The following sections describe the VMware Virtual SAN datastore scenarios for providing for resiliency and availability while performing day-to-day operations.

Host Maintenance Mode

For planned operations, the VMware Virtual SAN provides three host maintenance mode options: Ensure Accessibility, Full Data Migration, and No Data Migration.

Ensure Accessibility

The Ensure Accessibility option is the default host maintenance mode option. With this option, VMware Virtual SAN helps ensure that all accessible virtual machines on the host remain accessible when the host is either powered off or removed from the cluster.

With this option, typically only partial data evacuation is required. Select Ensure Accessibility to remove the host from the cluster temporarily, such as to install upgrades and then to return the host to the same cluster. Do not use this option to permanently remove the host from the cluster.

 

Full Data Migration

When Full Data Migration is selected, the VMware Virtual SAN moves all its data to other hosts in the cluster. Then it maintains or fixes availability compliance for the affected components in the cluster. The Full Data Migration option results in the largest amount of data transfer, and this migration consumes the most time and resources.

Select this option only when the host needs to be migrated permanently. When evacuating data from the last host in the cluster, make sure that you migrate the virtual machines to another datastore and then put the host in maintenance mode.

Note:    The host cannot enter maintenance mode if a virtual machine object that has data on the host is not accessible and cannot be fully evacuated.

 

With VMware Virtual SAN, placing a host in maintenance mode with Full Data Migration causes the virtual machine objects to be transferred to a different host. This migration is in addition to any virtual machines that were proactively migrated by administrators, because the host may have disk objects of virtual machines that reside on other hosts.

This transfer can be verified by using the vsan.resync_dashboard 10.0.108.15 -r 0 Ruby vSphere Console (RVC) command, which shows the data being migrated as shown on the following screen.

For more information about RVC, refer to Appendix C.

 

No Data Migration

When No Data Migration is selected, VMware Virtual SAN does not evacuate any data from this host. If the host is powered off or removed from the cluster, some virtual machines may become inaccessible.

VMware Virtual SAN Failure Simulations

During ongoing operations of a VMware Virtual SAN environment, in some cases either an individual disk failure or a host failure may affect virtual machine availability based on the storage policies applied. This section simulates these failure scenarios to provide an understanding of how VMware Virtual SAN maintains storage data that is highly available under different conditions. This discussion provides guidance when applying different levels of policies.

Magnetic Disk Failure Simulation

In a VMware Virtual SAN environment, if the magnetic disk that stores a virtual machine object fails, VMware Virtual SAN waits 60 minutes as its default repair-delay time before it rebuilds the disk object. If the failure is transient and the failed magnetic disk recovers prior to the end of this wait time, rebuilding is not required. The VMware Virtual SAN simply mirrors the disk objects from the replica.

Note that you can modify the VMware Virtual SAN default 60-minute repair-delay time [5].

For this simulation, summarized in Table 4, object placements for a test virtual machine are configured with FTT = 1 and default storage policies. The magnetic disk residing on the host using IP address 10.0.108.15 is unplugged from the server. (See the Non-SSD Disk Name and Non-SSD Disk UUID values for 10.0.108.15 highlighted in the table.)

Table 4.       Magnetic Disk Failure Simulation: Repair-Relay Time Not Reached

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.15

LSI Disk (naa.600605b00729ea601ad06df020766fb3)

5263c975-e1a7-fac7-a979-b5bfc3dededd

Local LSI Disk (naa.600605b00729ea601ad06df820ef02e7)

526aabec-434b-ce73-b6dd-6482e1535b11

Witness

Active

10.0.108.13

Local LSI Disk (naa.600605b0073a8020ff00009e098b7f65)

52200aeb-e555-5bd8-2b46-d1921ca1e31b

Local LSI Disk (naa.600605b0073a8020ff000098092fb8d1)

52173f38-2a73-10e4-31b4-6be150a82cd9

* CS = Component State

 


This simulation demonstrates a single disk failure scenario that keeps the virtual machine active and accessible because the failure is tolerable, as per FTT = 1. For the virtual machine storage policy, the disk compliance status is Not Compliant because the disk cannot tolerate any additional faults, as shown in the following screen.

 

Another way to check the disk object information is by using the RVC command vsan.disk_object_info. In this case, one of the disks is not found, as shown in the following screen.

 

After the repair-delay time is reached, VMware Virtual SAN rebuilds the disk objects from the replica and then uses a different disk, as shown in Table 5. (See the Non-SSD Disk Name and Non-SSD Disk UUID values for 10.0.108.15 highlighted in the table.)

Table 5.       Magnetic Disk Failure Simulation: Repair-Delay Time Expired

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.15

LSI Disk (naa.600605b00729ea601ad06df020766fb3)

5263c975-e1a7-fac7-a979-b5bfc3dededd

Local LSI Disk (naa.600605b00729ea601ad06e0721cb3825)

528c8b04-f6c7-cea9-770d-e1832e97e531

Witness

Active

10.0.108.13

Local LSI Disk (naa.600605b0073a8020ff00009e098b7f65)

52200aeb-e555-5bd8-2b46-d1921ca1e31b

Local LSI Disk (naa.600605b0073a8020ff000098092fb8d1)

52173f38-2a73-10e4-31b4-6be150a82cd9

 * CS = Component State

 


For the virtual machine storage policy, the rebuild provides a hard-disk compliance status of Compliant once again, as shown in the following screen.

 

By using the vsan.disk_object_info RCV command on the new disk, the virtual machine object constructs are found, as shown in the following screen.

 

SSD Failure Simulation

If am SSD in a VMware Virtual SAN disk group fails, the disk group becomes inaccessible, and the magnetic disks in the disk group do not contribute to the VMware Virtual SAN storage.

As in the magnetic disk failure simulation, when an SSD fails, the VMware Virtual SAN waits through a 60-minute default repair-delay time before it rebuilds the virtual machine objects from a different SSD: for instance, in the event of a nontransient failure.

The SSD failure simulation exhibits this behavior on a test virtual machine that is configured using the default storage policies and the disk placements shown in Table 6.

The SSD highlighted in Table 6 was unplugged from the server to simulate a hard failure. The SSD residing on the host using the IP address 10.0.108.13 is unplugged from the server. (See the SSD Disk Name and SSD Disk UUID values for 10.0.108.13 highlighted in the table.)


Table 6.       SSD Failure Simulation: Repair Delay Time Not Reached

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.13

Local LSI Disk (naa.600605b0073a8020ff0000a90a31aa58)

524296e8-95d1-49a1-983f-59d1fea4ae16

Local LSI Disk (naa.600605b0073a8020ff00009709213120)

52fa14cf-4917-1d6b-bb68-01bb8c919c6e

Witness

Active

10.0.108.14

Local LSI Disk (naa.600605b0072ca6e0ff00009809308c2e)

521c910e-badb-891c-fa3b-efcfba0009cd

Local LSI Disk (naa.600605b0072ca6e0ff00009b0961a896)

52d5a898-56a4-3430-734b-d9f5c1165d5e

* CS = Component State

 

For the virtual machine storage policy, the absent SSD makes the hard disk with components placed on the SSD not compliant with the FTT = 1 policy, as shown in the following screen. The virtual machine remains accessible while the hard disk is in the Not Compliant state because the data is served from the replica.

 

While the SSD is unplugged, the corresponding disk group on the host also becomes out of use, as shown in the following screen.

 


Another way to check the virtual machine object information is by using the vsan.vm_object_info RVC command. This command yields output about the layout of the disk objects associated with the virtual machine, as shown in the following screen.

 

After the repair-delay time is reached, if the SSD failure continues to exist, VMware Virtual SAN rebuilds the virtual machine layout using a different SSD, as shown in Table 7. (See the SSD Disk Name and SSD Disk UUID values for 10.0.108.13 highlighted in the table.)

Table 7.       Magnetic Disk Failure Simulation: Repair-Delay Time Expired

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.13

Local LSI Disk (naa.600605b0073a8020ff000095090d7333)

525e6181-3532-3bdb-7c78-9a6ea6929832

Local LSI Disk (naa.600605b0073a8020ff0000b00a9f5be9)

52584447-6e24-fcad-ee5b-f5597cbdec5a

Witness

Active

10.0.108.14

Local LSI Disk (naa.600605b0072ca6e0ff00009809308c2e)

521c910e-badb-891c-fa3b-efcfba0009cd

Local LSI Disk (naa.600605b0072ca6e0ff00009b0961a896)

52d5a898-56a4-3430-734b-d9f5c1165d5e

* CS = Component State

 


For the virtual machine storage policy, the rebuild provides a hard-disk compliance status of Compliant once again, as shown in the following screen.

 

Host Failure Simulation

When an unplanned host failure occurs, VMware vSphere advanced features, such as VMware High Availability, protect the virtual machines by moving them to a different host in a VMware Virtual SAN cluster.

However, with VMware Virtual SAN, the host may also have additional disk data for virtual machines residing on other hosts in the cluster. In this case, when a host failure occurs, VMware Virtual SAN rebuilds these disk objects on a different disk within a disk group on one of the other available hosts in the cluster. A virtual machine with a default fault-tolerance policy of 1 is still available for end users when a single host failure occurs because the replica serves the objects.

For this host failure simulation, a host with IP address 10.0.108.13 is powered off from Cisco UCS Manager, as shown in the following screen.

 

In addition, a test virtual machine with FTT = 1 is placed on host 10.0.108.12 with additional disk data residing on hosts 10.0.108.12 and 10.0.108.13, as shown in Table 8. (See the SSD Disk Name, SSD Disk UUID, Non-SSD Disk Name, and Non-SSD Disk UUID values for 10.0.108.13 highlighted in the table.)


Table 8.       Host Failure Simulation: TestVM Components

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.13

Local LSI Disk (naa.600605b0073a8020ff000095090d7333)

525e6181-3532-3bdb-7c78-9a6ea6929832

Local LSI Disk (naa.600605b0073a8020ff0000b00a9f5be9)

52584447-6e24-fcad-ee5b-f5597cbdec5a

Witness

Active

10.0.108.14

Local LSI Disk (naa.600605b0072ca6e0ff00009809308c2e)

521c910e-badb-891c-fa3b-efcfba0009cd

Local LSI Disk (naa.600605b0072ca6e0ff00009b0961a896)

52d5a898-56a4-3430-734b-d9f5c1165d5e

* CS = Component State

 

When 10.0.018.13 is powered off, the physical disk placement reports “Object not found” because the host is unavailable, as shown in the following screen.

 

Table 9.       Components Unavailable During Host Failure Simulation

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.13

Object not found

525e6181-3532-3bdb-7c78-9a6ea6929832

Object not found

52584447-6e24-fcad-ee5b-f5597cbdec5a

Witness

Active

10.0.108.14

Local LSI Disk (naa.600605b0072ca6e0ff00009809308c2e)

521c910e-badb-891c-fa3b-efcfba0009cd

Local LSI Disk (naa.600605b0072ca6e0ff00009b0961a896)

52d5a898-56a4-3430-734b-d9f5c1165d5e

* CS = Component State

 

In this case, the VMware Virtual SAN waits the default delay wait time and then rebuilds the components on to a different host from the cluster 10.0.108.15, as shown in Table 10. (See the SSD Disk Name, SSD Disk UUID, Non-SSD Disk Name, and Non-SSD Disk UUID values for 10.0.108.15 highlighted in the table.)


Table 10.     Components Rebuilt on Different Host

Type

CS*

Host

SSD Disk Name

SSD Disk UUID

Non-SSD Disk Name

Non-SSD Disk UUID

RAID1

Component

Active

10.0.108.12

Local LSI Disk (naa.600605b00730cf60ff00009a0953093c)

52426b0a-638f-3267-671b-a6227321ccbc

Local LSI Disk (naa.600605b00730cf60ff00009c09766fdf)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Component

Active

10.0.108.15

Local LSI Disk (naa.600605b00729ea601af1b56d2bac60cc)

52c75a2b-ed5d-98d1-d845-7350626b557

Local LSI Disk (naa.600605b00729ea601af1b56c2ba091c4)

52c2abc0-66dd-8aa5-542f-74ba3bbfe003

Witness

Active

10.0.108.14

Local LSI Disk (naa.600605b0072ca6e0ff00009809308c2e)

521c910e-badb-891c-fa3b-efcfba0009cd

Local LSI Disk (naa.600605b0072ca6e0ff00009b0961a896)

52d5a898-56a4-3430-734b-d9f5c1165d5e

* CS = Component State

 

VMware Virtual SAN Network Redundancy Verification

The VMware Virtual SAN VMkernel network is configured with redundant Cisco Data Center VM-FEX virtual networks connected to fabric interconnects A and B. These connections are configured as a PortChannel between the two uplinks, as shown in the following screen.

 

A physical NIC failure is simulated by disabling vmnic2, as shown in the following screen.

 

To verify that the VMware Virtual SAN traffic is not disrupted, disable the physical port from Cisco UCS Manager to display a continuous vmkping to the VMware Virtual SAN IP address on the dedicated network, as shown in the following screen.

Similar redundancy for the management network in a VMware Virtual SAN environment is also anticipated.

 

Benchmarking VMware Virtual SAN on Cisco UCS

VMware Virtual SAN is a scale-out storage solution that takes optimal advantage of the flash-tier using a read cache and a write buffer. All read and write I/O is sent through flash devices before it is destaged on the magnetic disks.

For read caching, VMware Virtual SAN distributes a directory of cached blocks between the VMware vSphere hosts in the cluster. The actual block that is read by the application running in the virtual machine may not be on the VMware vSphere host on which the virtual machine is running. This feature reduces the I/O read latency in the event of a cache hit.

Read caching enables a VMware vSphere host to determine whether a remote host has data cached that is not in a local cache. In this case, the VMware vSphere host can retrieve cached blocks from a remote host in the cluster over the VMware Virtual SAN network. If the block is not in the cache on any VMware Virtual SAN host, it is retrieved directly from the magnetic disks.

The write cache performs as a nonvolatile write buffer, which reduces the latency for write operations. Because all write operations go to SSD storage, VMware Virtual SAN helps ensure that a copy of the data exists elsewhere in the cluster. All virtual machines deployed to VMware Virtual SAN inherit the default availability policy settings. This feature helps ensure that at least one additional copy of the virtual machine data, including the write-cache contents, is always available.

After write operations have been initiated by the application running inside the guest operating system, they are sent in parallel to both the local write cache on the owning host and the write cache on the remote host. The write operation must be committed to SSD on both hosts before it is acknowledged.

In the event of a host failure, this approach helps ensure that a copy of the data exists on another flash device in the VMware Virtual SAN cluster, and that no data loss occurs. The virtual machine accesses the replicated copy of the data on another host in the cluster through the VMware Virtual SAN network.


In determining the performance and scalability of VMware Virtual SAN datastore, the following components play critical roles:

   VMware Virtual SAN storage policy configuration: The values specified for the storage policies have a direct impact on the resulting performance. For example, higher performance can be achieved with an FTT value of 0, although this setting does not provide redundancy for the virtual machines.

   Type of workload: IOPS capacity and overall performance achieved from the VMware Virtual SAN datastore varies based on the type of workload.

   Size of disk groups (scale up): Scaling up with VMware Virtual SAN is achieved by increasing the number of disks in a disk group or by increasing the number of disk groups per host.

   Size of VMware Virtual SAN cluster (scale out): Scaling out with VMware Virtual SAN is achieved by increasing the number of hosts in a VMware Virtual SAN cluster.

   Ratio of SSDs to magnetic disks: For VMware Virtual SAN, a 1:10 ratio of SSDs to magnetic disks is recommended, based on anticipated storage capacity use (not taking into account SPBM policies).

   Balanced cluster: Although VMware Virtual SAN supports the use of nodes within the cluster that do not contribute to storage, you should keep the cluster as balanced as possible. A balanced cluster provides better resiliency and performance than a highly unbalanced cluster with both contributing and noncontributing nodes.

   SSDs and magnetic disks: The sizes and specifications of the underlying SSDs and magnetic disks also have a direct impact on the overall performance of the VMware Virtual SAN datastore.

 

Benchmark Testing

Benchmarking tests for the Cisco UCS with VMware Virtual SAN solution were performed to provide guidance about the expected baseline capacity for this solution. The actual results may vary for specific workloads.

VMware Virtual SAN on the Cisco UCS C240 M3 achieved linear scalability while scaling up from a 4-node to an 8-node cluster for the following two types of IOPS benchmark tests:

   4K 100 percent Read, and with 80 percent randomness

   4K 70 percent Read with 30 percent Write, and with 80 percent randomness

 

For the benchmarking, average latency values of 20 milliseconds (ms) were considered to be the criteria for acceptable application response times in real-world scenarios. The maximum IOPS values obtained for a 4-node and an 8-node cluster demonstrate that a VMware Virtual SAN datastore scales in a linear fashion, as shown in Figures 4 and 5.

Figure 4.      IOPS Capacity for 4K 100 Percent Read 80 Percent Random Workload

 

Figure 5.      IOPS Capacity for 4K 70 Percent Read 30 Percent Write 80 Percent Random Workload

 

The benchmark testing was conducted using the I/O Analyzer tool [6], generating IO meter I/O loads to measure VMware Virtual SAN datastore performance. I/O Analyzer virtual machines were configured with the following specifications:

   4 x virtual CPUs (vCPUs) per I/O Analyzer

   8 x 8-GB VMDKs per I/O Analyzer to simulate parallel worker threads

   Custom configuration files (these configuration files are provided in Appendix A):

 

4K 100% Read, with 80% Random, and 4K 70% Read, with 30% Write, and with 80% Random100 Percent Read and 80 Percent Random

In this testing, the number of IO Analyzer virtual machines per host was gradually increased until the 20-ms latency values were reached, starting from a single I/O Analyzer virtual machine per host. For read I/O testing, 3 I/O Analyzers per host were used, for a total of 12 I/O Analyzers for 4-node testing and 24 I/O Analyzers for 8-node testing.

With default storage policies, VMware Virtual SAN provides redundancy (FTT = 1) through the use of replica images of the objects. For each VMDK on each I/O Analyzer, these objects are automatically placed on hosts in the cluster. For example, if IOWKR1 is on Host1, its individual VMDK objects are placed on any of the hosts within the cluster. Depending on the object placement, the IOPS on individual hosts will differ, as shown by the data. No manual effort was made to change this placement to reflect the real-world VMware Virtual SAN object placement scenario.

The 4-node and 8-node benchmarking that was used to obtain read IOPS values is shown in the following sections.

4-Node Read Benchmark Testing Results

Figures 6 through 8 show the results.

Figure 6.      4-Node Read IOPS Chart from I/O Analyzer Results

 

Figure 7.      4-Node Read I/O for Single-Host IOPS and Latency Graph from VSAN Observer

 

Figure 8.      4-Node 100 Percent Read 80 Percent Random I/O CPU Utilization Graph

 

8-Node Read Benchmark Testing Results

Figures 9 through 11 show the results.

Figure 9.      8-Node Read IOPS Chart from I/O Analyzer Results

 

Figure 10.    8-Node Read I/O for Single-Host IOPS and Latency Graph from VSAN Observer

 

Figure 11.    8-Node 100 Percent Read 80 Percent Random I/O CPU Utilization Graph

 

70 Percent Read, 30 Percent Write, and 80 Percent Random

For read-write I/O testing, a single I/O Analyzer per host was sufficient to achieve the IOPS values at
20-ms latencies.

The 4-node and 8-node benchmarking that was used to obtain Read-Write IOPS values is shown in the following sections.

4-Node Read-Write Benchmark Testing Results

Figures 12 through 14 show the results.

Figure 12.    4-Node Read-Write IOPS Chart from I/O Analyzer Results

 

Figure 13.    4-Node Read-Write I/O for Single-Host IOPS and Latency Graph from VSAN Observer

 

Figure 14.    4-Node 70 Percent Read 30 Percent Write 80 Percent Random I/O CPU Utilization Graph

 

8-Node Read-Write Benchmark Testing Results

Figures 15 through 17 show the results.

Figure 15.    8-Node Read-Write IOPS Chart from I/O Analyzer Results

 

Figure 16.    8-Node Read-Write I/O for Single-Host IOPS and Latency Graph from VSAN Observer

 

Figure 17.    8-Node 70 Percent Read 30 Percent Write 80 Percent I/O CPU Utilization Graph

 

Cisco UCS with VMware Virtual SAN Ready Nodes

The Cisco UCS with VMware Virtual SAN solution can be built using either of the following options:

   Build your own solution: Use the VMware Virtual SAN Compatibility Guide [3] to select the individual components that are required to build the solution.

   Choose a VMware Virtual SAN Ready Node: The VMware Virtual SAN Ready Node is a preconfigured single-node or multiple-node Cisco server hardware configuration that is based on the recommended configuration types for a VMware Virtual SAN solution.

 

Based on the Virtual SAN Ready System that is used, Cisco provides UCS Solution Accelerator Packs for VirtualVMware Virtual SAN. As an example, Table 11 shows the components in the Cisco UCS Starter Kit for VMware Virtual SAN (UCS-VSAN-IVB-28TBP).

Table 11.     Cisco UCS Starter Kit for VMware Virtual SAN (UCS-VSAN-IVB-28TBP)

Cisco UCS Starter Kit Components

Description

Cisco hardware configuration

2 x Cisco UCS 6248UP 48-Port Fabric Interconnects

4 x Cisco UCS C240 M3 Rack Servers:

  CPU: 2 x 2.60-GHz Intel Xeon processors E5-2650 v2
  Memory: 8 x 16 GB (128 GB total)
  Cisco UCS VIC 1225
  HDD: 7 x 1-TB SATA 7200-rpm SFF
  SSD: 1 x 800-GB SAS SSD
  LSI MegaRAID SAS 9271CV-8i controller

Node expansion

1 x Cisco UCS C240 M3 Rack Servers:

  CPU: 2 x 2.60-GHz Intel Xeon processors E5-2650 v2
  Memory: 8 x 16 GB (128 GB total)
  Cisco UCS VIC 1225

HDD: 7 x 1-TB SATA 7200-rpm SFF

Disk-group expansion

HDD:

  7 x 1-TB SATA 7200-rpm SFF

SSD:

  1 x 800-GB SAS SSD

 

Conclusion

Implementing VMware Virtual SAN on Cisco UCS allows customers to achieve great performance with a much simpler management experience, with Cisco UCS Manager centrally managing the infrastructure and VMware Virtual SAN integrated into VMware vSphere. Customers can continue to achieve the performance benefits of a Cisco UCS solution for applications hosted on their virtualized environments with VMware vSphere with VMware Virtual SAN as the hypervisor-converged storage solution.


Appendix A: IO Meter Custom Configuration Files

4k 70 Percent Read and 30 Percent Write, with 80 Percent Random

Version 2006.07.27
'TEST SETUP ====================================================================
'Test Description
          4k_70Read_80Rand_cust
'Run Time
'         hours  minutes   seconds
          0      1         0
'Ramp Up Time (s)
          0
'Default Disk Workers to Spawn
          NUMBER_OF_CPUS
'Default Network Workers to Spawn
          0
'Record Results
          ALL
'Worker Cycling
'         start  step   step type
          1      1      LINEAR
'Disk Cycling
'         start  step   step type
          1      1      LINEAR
'Queue Depth Cycling
'         start  end    step   step type
          1      32     2      EXPONENTIAL
'Test Type
          NORMAL
'END test setup
'ACCESS SPECIFICATIONS =========================================================
'Access specification name,default assignment
          4k; 70% Read; 80% Random, NONE
'size,% of size,% reads,% random,delay,burst,align,reply
          4096,100,70,80,0,1,4096,0
'END access specifications
'MANAGER LIST ==================================================================
'Manager ID, manager name
          1,IOA-manager
'Manager network address
          127.0.0.1
'Worker
          IOA-worker

'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdb
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdc
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdd
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sde
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1

'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdf
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdg
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdh
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          8388608,0
'End default target settings for worker
'Assigned access specs
          4k; 70% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdi
'Target type
          DISK
'End target
'End target assignments
'End worker
'End manager
'END manager list
Version 2006.07.27

4K 100 Percent Read, with 80 Percent Random

Version 2006.07.27
'TEST SETUP ====================================================================
'Test Description
          4k_100Read_100Rand_cust
'Run Time
'         hours  minutes   seconds
          0      1         0

'Ramp Up Time (s)
          0
'Default Disk Workers to Spawn
          NUMBER_OF_CPUS
'Default Network Workers to Spawn
          0
'Record Results
          ALL
'Worker Cycling
'         start  step   step type
          1  1      LINEAR
'Disk Cycling
'         start  step   step type
          1      1      LINEAR
'Queue Depth Cycling
'         start  end    step   step type
          1      32     2      EXPONENTIAL
'Test Type
          NORMAL
'END test setup
'ACCESS SPECIFICATIONS =========================================================
'Access specification name,default assignment
          4k; 100% Read; 80% Random, NONE
'size,% of size,% reads,% random,delay,burst,align,reply
          4096,100,100,80,0,1,4096,0
'END access specifications
'MANAGER LIST ==================================================================
'Manager ID, manager name
          1,IOA-manager
'Manager network address
          127.0.0.1
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdb
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdc
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdd

'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sde
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdf
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdg
'Target type
          DISK
'End target
'End target assignments
'End worker
'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdh
'Target type
          DISK
'End target
'End target assignments
'End worker

'Worker
          IOA-worker
'Worker type
          DISK
'Default target settings for worker
'Number of outstanding IOs,test connection rate,transactions per connection
          16,DISABLED,1
'Disk maximum size,starting sector
          0,0
'End default target settings for worker
'Assigned access specs
          4k; 100% Read; 80% Random
'End assigned access specs
'Target assignments
'Target
          sdi
'Target type
          DISK
'End target
'End target assignments
'End worker
'End manager
'END manager list
Version 2006.07.27

Appendix B: VMware Virtual SAN Requirements

Table 12 lists VMware Virtual SAN prerequisites, and Table 13 lists limitations and recommendations.

Table 12.     VMware Virtual SAN Prerequisites

Component

Description

VMware vCenter Server

Minimum Version 5.5 Update 1

VMware vSphere

Minimum Version 5.5

Hosts

Minimum 3 VMware ESXi hosts

Disk controller

Requires one of the following:

  SAS or SATA HBA
  RAID controller; must function in either pass-through (preferred) or RAID 0 mode

Hard disk drives

Minimum 1 SAS, NL-SAS, or SATA magnetic hard drive per host

Flash-memory-based devices

Minimum 1 SAS, SATA, or PCIe SSD per host

Network interface cards (NICs)

Minimum one 1- or 10-Gbps (recommended) network adapter per host

Virtual switch

VMware vSphere standard switch or distributed switch or Cisco Data Center VM-FEX

VMkernel network

Minimum one 1- or 10-Gbps (recommended) network adapter per host

 

Table 13.     VMware Virtual SAN Limitations and Recommendations

Limitations and Recommendations

Description

Limitations

  Maximum 32 hosts per VMware Virtual SAN cluster
  Maximum 5 disk groups per host
  Maximum 7 magnetic disks per disk group
  Maximum 1 SSD per disk group

Recommendations

  All cluster hosts share identical hardware configuration.
  All cluster hosts have the same number of disk groups.
  An SSD–to–magnetic disk capacity ratio of 1:10 of the anticipated consumed storage capacity is required before the FTT value is considered.
  Each cluster host has a single VMkernel NIC enabled for VMware Virtual SAN.

 


Appendix C: Ruby vSphere Console and VMware VSAN Observer

Ruby vSphere Console (RVC) [7] is a Linux console user interface for VMware ESXi and vCenter. RVC is installed on VMware vCenter as a requirement for using VSAN Observer commands.

VSAN Observer is a part of RVC, and it is recommended for more advanced, deeper visibility into a VMware Virtual SAN environment. For this solution, VSAN Observer was extensively used to monitor all performance results and maintenance and availability operations.

Table 14 lists the VSAN Observer commands that were used for this solution.

Table 14.     VSAN Observer Commands

VSAN Observer Command

Description

vsan.resync_dashboard 10.0.108.15 -r 0

Observe data migration while placing hosts in Full Migration maintenance mode.

vsan.disk_object_info

Verify disk object information.

vsan.vm_object_info

Verify virtual machine object information.

vsan.disks_info hosts/10.0.108.15

Obtain a list of disks on a specific host.

vsan.obj_status_report

Obtain health information about VMware Virtual SAN objects. This command is helpful in identifying orphaned objects.

vsan.reapply_vsan_vmknic_config

Re-enable VMware Virtual SAN on VMkernel ports while performing network configuration–related troubleshooting.

vsan.observer {cluster name} -r -o -g /tmp -i 30 -m 1

Enable and capture performance statistics used for benchmark testing.

See also [8].

 

For a more comprehensive list of VSAN Observer command, please refer to [9].


Appendix D: Cisco Part Numbers     

Table 15 provides Cisco part numbers for the components used in this solution.

Table 15.     Cisco Ordering Information

Component

Cisco Part Number

Cisco UCS C240 M3 server

UCSC-C240-M3S

8-GB DDR3 1600-MHz RDIMM PC3-12800, dual rank, 1.35V

UCS-MR-1X082RY-A

Seagate 1-TB SATA disk

A03-D1TBSATA

Cisco UCS VIC 1225 CNA

UCSC-PCIE-CSC-02

Cisco FlexFlash card

UCS-SD-16G

Cisco UCS 6248UP fabric interconnect

UCS-FI-6248UP

 


 

Resources

1.     What’s new in VMware Virtual SAN

2.     Cisco FlexFlash: Use and manage Cisco Flexible Flash internal SD card for Cisco UCS C-Series standalone rack servers

3.     VMware Virtual SAN compatibility guide

4.     LSI

5.     Changing the default repair-delay time for a host failure in VMware Virtual SAN

6.     IO Analyzer

7.     Ruby vSphere Console (RVC)

8.     Enabling or capturing performance statistics using VMware Virtual SAN Observer

9.     VMware Virtual SAN quick monitoring and troubleshooting reference guide

10.   Cisco UCS C240 M3 high-density rack server (SFF disk-drive model) specification sheet

11.   Working with VMware Virtual SAN

12.   VMware Virtual SAN Ready System recommended configurations

13.   Enabling or capturing statistics using VMware Virtual SAN Observer for VMware Virtual SAN Resources

 

Acknowledgements

The following individuals contributed to this paper:

Bhumik Patel, Partner Architect, VMware

John Kennedy, Technical Marketing Engineer, Cisco Systems

Wade Holmes, Senior Technical Marketing Architect, VMware

 