SAN Ports and Port Channels

Port Modes

The port mode determines whether a unified port on the fabric interconnect is configured to carry Ethernet or Fibre Channel traffic. You configure the port mode in Cisco UCS Manager. However, the fabric interconnect does not automatically discover the port mode.

Changing the port mode deletes the existing port configuration and replaces it with a new logical port. Any objects associated with that port configuration, such as VLANs and VSANS, are also removed. There is no restriction on the number of times you can change the port mode for a unified port.

Port Types

The port type defines the type of traffic carried over a unified port connection.

By default, unified ports changed to Ethernet port mode are set to the Ethernet uplink port type. Unified ports changed to Fibre Channel port mode are set to the Fibre Channel uplink port type. You cannot unconfigure Fibre Channel ports.

Changing the port type does not require a reboot.

Ethernet Port Mode

When you set the port mode to Ethernet, you can configure the following port types:

  • Server ports

  • Ethernet uplink ports

  • Ethernet port channel members

  • FCoE ports

  • Appliance ports

  • Appliance port channel members

  • SPAN destination ports

  • SPAN source ports


    Note


    For SPAN source ports, configure one of the port types and then configure the port as SPAN source.


Fibre Channel Port Mode

When you set the port mode to Fibre Channel, you can configure the following port types:

  • Fibre Channel uplink ports

  • Fibre Channel port channel members

  • Fibre Channel storage ports

  • SPAN source ports


    Note


    For SPAN source ports, configure one of the port types and then configure the port as SPAN source.


Server Ports

Configuring Server Ports

All of the port types listed are configurable on both the fixed module and expansion module, including the server ports.

This task describes only one method of configuring ports. You can also configure ports from a right-click menu, or in the LAN Uplinks Manager.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name > Fixed Module > Ethernet Ports.

Step 3

Click a port under the Ethernet Ports node.

Step 4

In the Work pane, click the General tab.

Step 5

In the Actions area, click Reconfigure.

Step 6

From the drop-down list, choose Configure as Server Port.


Reconfiguring a Port on a Fabric Interconnect

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to reconfigure.

Step 4

Click the port or ports that you want to reconfigure.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Reconfigure.

Step 7

From the drop-down list, choose which way you want the port reconfigured.


Example: Reconfiguring an Uplink Ethernet Port as a Server Port

  1. Expand the Ethernet Ports node and select the port you want to reconfigure.

  2. Follow steps 5 and 6 above.

  3. From the drop-down list choose Configure as Server Port.

Enabling or Disabling a Port on a Fabric Interconnect

After you enable or disable a port on a fabric interconnect, wait for at least 1 minute before you re-acknowledge the chassis. If you re-acknowledge the chassis too soon, the pinning of server traffic from the chassis might not get updated with the changes to the port that you enabled or disabled.

You can enable or disable a port only when it is configured. If the port is unconfigured, the enable and disable options are not active.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to enable or disable.

Step 4

Under the Ethernet Ports node, select a port.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Enable Port or Disable Port.

Step 7

If a confirmation dialog box displays, click Yes.

Step 8

Click OK.


Unconfiguring a Port on a Fabric Interconnect

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to unconfigure.

Step 4

Under the Ethernet Ports node, select a port.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Unconfigure.

Step 7

If a confirmation dialog box displays, click Yes.

Step 8

Click OK.


Appliance Ports

Appliance ports are only used to connect fabric interconnects to directly attached NFS storage.

Note


When you create a new appliance VLAN, its IEEE VLAN ID is not added to the LAN Cloud. Therefore, appliance ports that are configured with the new VLAN remain down, by default, due to a pinning failure. To bring up these appliance ports, you have to configure a VLAN in the LAN Cloud with the same IEEE VLAN ID.


Cisco UCS Manager supports up to four appliance ports per fabric interconnect.

Configuring an Appliance Port

You can configure Appliance ports on either the fixed module or an expansion module.

This task describes only one method of configuring appliance ports. You can also configure appliance ports from the General tab for the port.


Note


If you configure an appliance port when the uplink port is down, Cisco UCS Manager may display an error message stating that the appliance port has failed. This message is controlled by the Action on Uplink Fail option in the associated Network Control Policy.


Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to configure.

Step 4

Under the Ethernet Ports node, select a port.

If you want to reconfigure a server port, uplink Ethernet port, or FCoE storage port, expand the appropriate node.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Reconfigure.

Step 7

From the drop-down list, click Configure as Appliance Port.

Step 8

If a confirmation dialog box displays, click Yes.

Step 9

In the Configure as Appliance Port dialog box, complete the required fields.

Step 10

In the VLANs area, do the following:

  1. In the Port Mode field, click one of the following radio buttons to select the mode you want to use for the port channel:

    • Trunk—Cisco UCS Manager GUI displays the VLANs Table that lets you choose the VLANs you want to use.

    • Access—Cisco UCS Manager GUI displays the Select VLAN drop-down list that allows you to choose a VLAN to associate with this port or port channel.

    With either mode, you can click the Create VLAN link to create a new VLAN.

    Note

     

    If traffic for the appliance port needs to traverse the uplink ports, you must also define each VLAN used by this port in the LAN cloud. For example, you need the traffic to traverse the uplink ports if the storage is also used by other servers, or if you want to ensure that traffic fails over to the secondary fabric interconnect if the storage controller for the primary fabric interconnect fails.

  2. If you clicked the Trunk radio button, complete the required fields in the VLANs table.

  3. If you clicked the Access radio button, choose a VLAN from the Select VLAN drop-down list.

Step 11

(Optional) If you want to add an endpoint, check the Ethernet Target Endpoint check box and specify the name and MAC address.

Step 12

Click OK.


Modifying the Properties of an Appliance Port

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the appliance port that you want to modify.

Step 4

Expand Ethernet Ports.

Step 5

Click the appliance port for which you want to modify the properties.

Step 6

In the Work pane, click the General tab.

Step 7

In the Actions area, click Show Interface.

You may need to expand the pane or use the scroll bars in the Properties dialog box to see all the fields.

Step 8

In the Properties dialog box, modify the values as needed.

Step 9

Click OK.


FCoE and Fibre Channel Storage Ports

Configuring an Ethernet Port as an FCoE Storage Port

You can configure FCoE storage ports on either the fixed module or an expansion module.

This task describes only one method of configuring FCoE storage ports. You can also configure FCoE storage ports from the General tab for the port.

Before you begin

The Fibre Channel switching mode must be set to Switching for these ports to be valid. The storage ports cannot function in end-host mode.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Depending upon the location of the ports you want to configure, expand one of the following:

  • Fixed Module

  • Expansion Module

Step 4

Click one or more of the ports under the Ethernet Ports node.

If you want to reconfigure an uplink Ethernet port, server port, or appliance port, expand the appropriate node.

Step 5

Right-click the selected port or ports and choose Configure as FCoE Storage Port.

On Cisco UCS 6454 Fabric Interconnects, ports 49-54 cannot be configured as FCoE storage ports.

On Cisco UCS 64108 Fabric Interconnects, ports 97-108 cannot be configured as FCoE storage ports.

Step 6

If a confirmation dialog box displays, click Yes.

Step 7

Click OK.


Configuring a Fibre Channel Storage Port

This task describes only one method of configuring FC storage ports. You can also configure FC storage ports from the General tab for the port.

Before you begin

The Fibre Channel switching mode must be set to Switching for these ports to be valid. The storage ports cannot function in end-host mode.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the Expansion Module node.

Step 4

Click one or more of the ports under the FC Ports node.

Step 5

Right-click the selected port or ports and choose Configure as FC Storage Port.

Step 6

If a confirmation dialog box displays, click Yes.

Step 7

Click OK.


Restoring an Uplink Fibre Channel Port

This task describes only one method of restoring an FC storage port to function as an uplink FC port. You can also reconfigure FC storage ports from the General tab for the port.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the Expansion Module node.

Step 4

Click one or more of the ports under the FC Ports node.

Step 5

Right-click the selected port or ports and choose Configure as Uplink Port.

Step 6

If a confirmation dialog box displays, click Yes.

Step 7

Click OK.


FC Links Rebalancing

The FC uplinks balance automatically when FC Port Channels are utilized. To create FC Port Channels, refer to Creating a Fibre Channel Port Channel.

For the FC uplinks that are not members of the Port Channels (Individual ISLs), load balancing is done according to the FC uplinks balancing algorithm. For a vHBA of a host or service profile to choose an available FC uplink, when FC uplink trunking is disabled, the uplink and vHBA must belong to the same VSAN

For each vHBA, the algorithm searches for an FC uplink in the following order:
  1. Least used FC uplink based on the number of vHBAs currently bound to the uplink.

  2. If FC uplinks are equally balanced, then round robin is used.

This process continues for all the other vHBAs. The algorithm also considers other parameters such as pre-fip/fip adapters and number of flogis. You may not see the least-used component when there are less than six flogis.

After a port configuration or any other uplink state changes, if the traffic passing through the FC uplinks is no longer balanced, you can re-balance the traffic by resetting the vHBA(s) on each adapter and allow the load balancing algorithm to evaluate for the current state of the FC uplinks.

Converting FC Storage Port to FC Uplink Port

You can configure an FC Uplink port on either a fixed module or an expansion module.

This task describes only one method of configuring FC Uplink ports. You can also configure FC uplink ports from a right-click menu for the port.


Important


The fill pattern is greyed out and is automatically set to IDLE on Cisco UCS 6500 Series Fabric Interconnects and Cisco UCS 6400 Series Fabric Interconnect.


Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to configure.

Step 4

Under the FC Ports node, select any Storage port.

Step 5

In the Work pane, click the General tab.

Step 6

From the Actions area, select Configure as Uplink Port.

Step 7

If a confirmation dialog box displays, click Yes.

Step 8

The Cisco UCS Manager GUI displays a success message.

In the Actions area, Configure as Uplink Port becomes grayed out and Configure as FC Storage Port becomes active.


FCoE Uplink Ports

FCoE uplink ports are physical Ethernet interfaces between the fabric interconnects and the upstream Ethernet switch, used for carrying FCoE traffic. With this support the same physical Ethernet port can carry both Ethernet traffic and Fibre Channel traffic.

FCoE uplink ports connect to upstream Ethernet switches using the FCoE protocol for Fibre Channel traffic. This allows both the Fibre Channel traffic and Ethernet traffic to flow on the same physical Ethernet link.


Note


FCoE uplinks and unified uplinks enable the multi-hop FCoE feature, by extending the unified fabric up to the distribution layer switch.


You can configure the same Ethernet port as any of the following:

  • FCoE uplink port—As an FCoE uplink port for only Fibre Channel traffic.

  • Uplink port—As an Ethernet port for only Ethernet traffic.

  • Unified uplink port—As a unified uplink port to carry both Ethernet and Fibre Channel traffic.

Configuring FCoE Uplink Ports

You can configure an FCoE Uplink port on either a fixed module or an expansion module.

This task describes only one method of configuring FCoE Uplink ports. You can also configure FCoE uplink ports from a right-click menu or from the General tab for the port.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to configure.

Step 4

Under the Ethernet Ports node, select any Unconfigured port.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Reconfigure.

Step 7

From the drop down options, select Configure as FCoE Uplink Port.

Step 8

If a confirmation dialog box displays, click Yes.

Step 9

The Cisco UCS Manager GUI displays a success message.

In the Properties area, the Role changes to Fcoe Uplink.


Unified Storage Ports

Unified storage involves configuring the same physical port as both an Ethernet storage interface and an FCoE storage interface. You can configure any appliance port or FCoE storage port as a unified storage port. To configure a unified storage port, you must have the fabric interconnect in Fibre Channel switching mode.

In a unified storage port, you can enable or disable individual FCoE storage or appliance interfaces.

  • In an unified storage port, if you do not specify a non-default VLAN for the appliance port, the FCoE-storage-native-vlan will be assigned as the native VLAN on the unified storage port. If the appliance port has a non-default native VLAN specified as native VLAN, this will be assigned as the native VLAN for the unified storage port.

  • When you enable or disable the appliance interface, the corresponding physical port is enabled or disabled. So when you disable the appliance interface in unified storage, even if the FCoE storage is enabled, it goes down with the physical port.

  • When you enable or disable the FCoE storage interface, the corresponding VFC is enabled or disabled. So when the FCoE storage interface is disabled in a unified storage port, the appliance interface will continue to function normally.

Configuring an Appliance Port as a Unified Storage Port

You can configure a unified storage port either from an appliance port or from an FCoE storage port. You can also configure the unified storage port from an unconfigured port. If you start from an unconfigured port, you will assign either an appliance configuration or an FCoE storage configuration to the port, and then will add another configuration to enable it as a unified storage port.


Important


Make sure the fabric interconnect is in Fibre Channel switching mode.


Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Depending on the location of the ports you want to configure, expand one of the following:

  • Fixed Module

  • Expansion Module

Step 4

Under the Ethernet Ports node, select any the port that is already configured as an appliance port.

In the Work pane, under the General tab, in the Properties area, the Role will show as Appliance Storage.

Step 5

In the Actions area, click Reconfigure.

Step 6

From the pop-up menu, select Configure as FCoE Storage port.

Step 7

If a confirmation dialog box displays, click Yes.

Step 8

The Cisco UCS Manager GUI displays a success message. In the Properties area, the Role changes to Unified Storage.


Unconfiguring a Unified Storage Port

You can unconfigure and remove both configurations from the unified connect port. Or you can unconfigure either of them and retain the other on the port.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to unconfigure.

Step 4

Under the Ethernet Ports node, select the port that you want to unconfigure.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Unconfigure. You will see the following options:

  • Unconfigure FCoE Storage Port

  • Unconfigure Appliance Port

  • Unconfigure both

Step 7

Select one of the unconfigure options.

Step 8

If a confirmation dialog box displays, click Yes.

Step 9

The Cisco UCS Manager GUI displays a success message. In the Properties area, the Role changes to based on your unconfigure selection.


Unified Uplink Ports

When you configure an Ethernet uplink and an FCoE uplink on the same physical Ethernet port, it is called a unified uplink port. You can individually enable or disable either the FCoE or Ethernet interfaces independently.

  • Enabling or disabling the FCoE uplink results in the corresponding VFC being enabled or disabled.

  • Enabling or disabling an Ethernet uplink results in the corresponding physical port being enabled or disabled.

If you disable an Ethernet uplink, it disables the underlying physical port in a unified uplink. Therefore, even when the FCoE uplink is enabled, the FCoE uplink also goes down. But if you disable an FCoE uplink, only the VFC goes down. If the Ethernet uplink is enabled, it can still function properly in the unified uplink port.

Configuring Unified Uplink Ports

You can configure the unified uplink port from either of the following:

  • From an existing FCoE uplink port or Ethernet uplink port

  • From an unconfigured uplink port

You can configure the unified uplink port on either a fixed module or on an expansion module.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to configure.

Step 4

Under the Ethernet Ports node, select a port.

Step 5

In the Work pane, click the General tab.

Step 6

In the Properties area, make sure the Role shows as Fcoe Uplink.

Step 7

In the Actions area, click Reconfigure.

Step 8

From the drop-down options, select Configure as Uplink Port.

Step 9

If a confirmation dialog box displays, click Yes.

Step 10

The Cisco UCS Manager GUI displays a success message.

In the Properties area, the Role changes to Unified Uplink.


Unconfiguring Unified Uplink Port

You can unconfigure and remove both configurations from the unified uplink port. Or you can unconfigure either the FCoE configuration or Ethernet port configuration and retain the other on the port.

Procedure


Step 1

In the Navigation pane, click Equipment.

Step 2

Expand Equipment > Fabric Interconnects > Fabric_Interconnect_Name.

Step 3

Expand the node for the ports that you want to unconfigure.

Step 4

Under the Ethernet Ports node, select the port you want to unconfigure.

Step 5

In the Work pane, click the General tab.

Step 6

In the Actions area, click Unconfigure. Select one of the following options:

  • Unconfigure FCoE Uplink Port

  • Unconfigure Uplink Port

  • Unconfigure both

Step 7

If a confirmation dialog box displays, click Yes.

Step 8

The Cisco UCS Manager GUI displays a success message. In the Properties area, the Role changes based on your unconfigure selection.

Step 9

Click Save Changes.


Policy-Based Port Error Handling

If Cisco UCS Manager detects any errors on active network interface (NI) ports, and if the error-disable feature has been implemented, Cisco UCS Manager automatically disables the respective fabric interconnect port that is connected to the NI port that had errors. When a fabric interconnect port is error disabled, it is effectively shut down and no traffic is sent or received on that port.

The error-disable function serves two purposes:

  • It lets you know which fabric interconnect port is error-disabled and that the connected NI Port has errors.

  • It eliminates the possibility that this port can cause the failure of other ports other ports connected to the same Chassis/FEX. Such a failure can occur when the NI port has errors, which can ultimately cause serious network issues. The error-disable function helps prevent these situations.

Configuring Error-Based Action

Procedure


Step 1

In the Navigation pane, click Admin.

Step 2

Expand Admin > All > Stats Management > fabric > Internal LAN > thr-policy-default > etherNiErrStats.

Step 3

Select a delta property.

Step 4

In the Work pane, click the General tab.

Step 5

To implement an error-disable state on a fabric interconnect port, check the Disable FI port when fault is raised check box.

Step 6

To enable auto recovery, in the Enable Auto Recovery field, select Enable.

Step 7

To specify the time after which the port can automatically be re-enabled, in the Time (in minutes) field, type the desired value.

Step 8

Click Save Changes.


Fibre Channel Port Channels

A Fibre Channel port channel allows you to group several physical Fibre Channel ports (link aggregation) to create one logical Fibre Channel link to provide fault-tolerance and high-speed connectivity. In Cisco UCS Manager, you create a port channel first and then add Fibre Channel ports to the port channel.


Note


Fibre Channel port channels are not compatible with non-Cisco technology.


You can create up to four Fibre Channel port channels in each Cisco UCS domain with Cisco UCS 6200, 6300, , and 6400 Series Fabric Interconnects. Each Fibre Channel port channel can include a maximum of 16 uplink Fibre Channel ports.

You can create up to two Fibre Channel port channels in each Cisco UCS domain with Cisco UCS 6324 fabric interconnects. Each Fibre Channel port channel can include a maximum of four uplink Fibre Channel ports.

For more information, see Port Breakout Functionality on respective fabric interconnects in Network Management Guide.

Ensure that the Fibre Channel port channel on the upstream NPIV switch is configured with its channel mode as active. If both the member port(s) and peer port(s) do not have the same channel mode configured, the port channel will not come up. When the channel mode is configured as active, the member ports initiate port channel protocol negotiation with the peer port(s) regardless of the channel group mode of the peer port. If the peer port, while configured in a channel group, does not support the port channel protocol, or responds with a nonnegotiable status, it defaults to the On mode behavior. The active port channel mode allows automatic recovery without explicitly enabling and disabling the port channel member ports at either end.

This example shows how to configure channel mode as active:

switch(config)# int po114
switch(config-if)# channel mode active

Creating a Fibre Channel Port Channel

Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

Expand SAN > SAN Cloud.

Step 3

Expand the node for the fabric where you want to create the port channel.

Step 4

Right-click the FC Port Channels node and choose Create Port Channel.

Step 5

In the Set Port Channel Name panel, specify the ID and name, then click Next.

Step 6

In the Add Ports panel, specify the port channel admin speed, and add ports to the port channel.

Port Channel Admin Speed 1 Gbps and 2 Gbps are not available for Cisco UCS 6400 Series Fabric Interconnect. Port Channel Admin Speed 16 Gbps and 32 Gbps are available only for Cisco UCS 6400 Series Fabric Interconnect.

Step 7

Click Finish.


Enabling a Fibre Channel Port Channel

Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

Expand SAN > SAN Cloud > Fabric > FC Port Channels.

Step 3

Click the port channel you want to enable.

Step 4

In the Work pane, click the General tab.

Step 5

In the Actions area, click Enable Port Channel.

Step 6

If a confirmation dialog box displays, click Yes.


Disabling a Fibre Channel Port Channel

Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

Expand SAN > SAN Cloud > Fabric > FC Port Channels.

Step 3

Click the port channel you want to disable.

Step 4

In the Work pane, click the General tab.

Step 5

In the Actions area, click Disable Port Channel.

Step 6

If a confirmation dialog box displays, click Yes.


Adding Ports to and Removing Ports from a Fibre Channel Port Channel

Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

Expand SAN > SAN Cloud > Fabric > FC Port Channels.

Step 3

Click the port channel to which you want to add or remove ports.

Step 4

In the Work pane, click the General tab.

Step 5

In the Actions area, click Add Ports.

Step 6

In the Add Ports dialog box, do one of the following:

  • To add ports, choose one or more ports in the Ports table, and then click the >> button to add the ports to the Ports in the port channel table.
  • To remove ports, choose one or more ports in the Ports in the port channel table, and then click the << button to remove the ports from the port channel and add them to the Ports table.

Step 7

Click OK.


Modifying the Properties of a Fibre Channel Port Channel


Note


If you are connecting two Fibre Channel port channels, the admin speed for both port channels must match for the link to operate. If the admin speed for one or both of the Fibre Channel port channels is set to auto, Cisco UCS adjusts the admin speed automatically.


Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

Expand SAN > SAN Cloud > Fabric > FC Port Channels.

Step 3

Click the port channel that you want to modify.

Step 4

In the Work pane, click the General tab.

Step 5

In the Properties area, change the values in one or more of the following fields:

Name Description

Name field

The user-defined name given to the port channel. This name can be between 1 and 16 alphanumeric characters.

VSAN drop-down list

The VSAN associated with the port channel.

Port Channel Admin Speed drop-down list

The admin speed of the port channel. This can be:

  • 1 Gbps

    Note

     

    Not available for Cisco UCS 6400 Series Fabric Interconnect.

  • 2 Gbps

    Note

     

    Not available for Cisco UCS 6400 Series Fabric Interconnect.

  • 4 Gbps

  • 8 Gbps

  • 16 Gbps

    Note

     

    Available only for Cisco UCS 6400 Series Fabric Interconnect.

  • 32 Gpbs

    Note

     

    Available only for Cisco UCS 6400 Series Fabric Interconnect.

  • auto

    Note

     

    Not available for Cisco UCS 6400 Series Fabric Interconnect.

Step 6

Click Save Changes.


Deleting a Fibre Channel Port Channel

Procedure


Step 1

In the Navigation pane, click LAN.

Step 2

Expand SAN > SAN Cloud > Fabric > FC Port Channels.

Step 3

Right-click the port channel you want to delete and choose Delete.

Step 4

If a confirmation dialog box displays, click Yes.


FCoE Port Channels

An FCoE port channel allows you to group several physical FCoE ports to create one logical FCoE port channel. At a physical level, the FCoE port channel carries FCoE traffic over an Ethernet port channel. So an FCoE port channel with a set of members is essentially an Ethernet port channel with the same members. This Ethernet port channel is used as a physical transport for FCoE traffic.

For each FCoE port channel, Cisco UCS Manager creates a VFC internally and binds it to an Ethernet port channel. FCoE traffic received from the hosts is sent over the VFC the same way as the FCoE traffic is sent over Fibre Channel uplinks.

Creating an FCoE Port Channel

Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

Expand SAN > SAN Cloud.

Step 3

Expand the node for the fabric where you want to create the port channel.

Step 4

Right-click the FCoE Port Channels node and choose Create FCoE Port Channel.

Step 5

In the Set Port Channel Name panel of the Create FCoE Port Channel wizard, specify the ID and name, then click Next.

Step 6

In the Add Ports panel of the Create FCoE Port Channel wizard, specify the ports that you want to add.

Step 7

Click Finish.


Deleting an FCoE Port Channel

Procedure


Step 1

In the Navigation pane, click SAN.

Step 2

On the SAN tab, expand SAN > SAN Cloud > Fabric > FCoE Port Channels.

Step 3

Right-click the port channel you want to delete and choose Delete.

Step 4

If a confirmation dialog box displays, click Yes.


Unified Uplink Port Channel

When you create an Ethernet port channel and an FCoE port channel with the same ID, it is called a unified uplink port channel. When the unified port channel is created, a physical Ethernet port channel and a VFC are created on the fabric interconnect with the specified members. The physical Ethernet port channel is used to carry both Ethernet and FCoE traffic. The VFC binds FCoE traffic to the Ethernet port channel.

The following rules will apply to the member port sets of the unified uplink port channel:

  • The Ethernet port channel and FCoE port channel on the same ID, must have the same set of member ports.

  • When you add a member port channel to the Ethernet port channel, Cisco UCS Manager adds the same port channel to FCoE port channel as well. Similarly, adding a member to the FCoE port channel adds the member port to the Ethernet port channel.

  • When you delete a member port from one of the port channels, Cisco UCS Manager automatically deletes the member port from the other port channel.

If you disable an Ethernet uplink port channel, it disables the underlying physical port channel in a unified uplink port channel. Therefore, even when the FCoE uplink is enabled, the FCoE uplink port channel also goes down. If you disable an FCoE uplink port channel, only the VFC goes down. If the Ethernet uplink port channel is enabled, it can still function properly in the unified uplink port channel.