Viewing Server Sensors
This chapter includes the following sections:
- Viewing the Fault Summary
- Viewing Power Supply Sensors
- Viewing Fan Sensors
- Viewing Temperature Sensors
- Viewing Voltage Sensors
- Viewing Current Sensors
- Viewing Storage Sensors
Viewing the Fault Summary
This example displays a summary of faults from discrete sensors:
Server# scope fault Server /fault # show discrete-alarm Name Reading Sensor Status ------------ -------------------- ------------------------------------ PSU2_STATUS absent Critical Server /fault #
Viewing Power Supply Sensors
This example displays power supply sensor statistics:
Server# scope sensor
Server /sensor # show psu
Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure
-------------------- -------------------- ---------- ---------- --------------- --------------- --------------- ---------------
PSU1_STATUS Normal present
PSU2_STATUS Normal present
Server /sensor # show psu-redundancy
Name Reading Sensor Status
-------------------- ---------- --------------------
PSU_REDUNDANCY full Normal
Server /sensor #
Viewing Fan Sensors
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope sensor | Enters sensor command mode. |
| Step 2 | Server /sensor # show fan [detail] | Displays fan sensor statistics for the server. |
This example displays fan sensor statistics:
Server# scope sensor Server /sensor # show fan Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure -------------------- -------------- ---------- ---------- --------------- --------------- --------------- --------------- W793_FAN2_TACH1 Normal 2400 RPM N/A N/A 800 N/A W793_FAN2_TACH2 Normal 2400 RPM N/A N/A 800 N/A W793_FAN3_TACH1 Normal 2300 RPM N/A N/A 800 N/A W793_FAN3_TACH2 Normal 2300 RPM N/A N/A 800 N/A W793_FAN4_TACH1 Normal 2400 RPM N/A N/A 800 N/A W793_FAN4_TACH2 Normal 1600 RPM N/A N/A 800 N/A Server /sensor #
Viewing Temperature Sensors
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope sensor | Enters sensor command mode. |
| Step 2 | Server /sensor # show temperature [detail] | Displays temperature sensor statistics for the server. |
This example displays temperature sensor statistics:
Server# scope sensor Server /sensor # show temperature Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ IOH_TEMP_SENS Normal 32.0 C N/A 80.0 N/A 85.0 P2_TEMP_SENS Normal 31.0 C N/A 80.0 N/A 81.0 P1_TEMP_SENS Normal 34.0 C N/A 80.0 N/A 81.0 DDR3_P2_D1_TMP Normal 20.0 C N/A 90.0 N/A 95.0 DDR3_P1_A1_TMP Normal 21.0 C N/A 90.0 N/A 95.0 FP_AMBIENT_TEMP Normal 28.0 C N/A 40.0 N/A 45.0 Server /sensor #
Viewing Voltage Sensors
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope sensor | Enters sensor command mode. |
| Step 2 | Server /sensor # show voltage [detail] | Displays voltage sensor statistics for the server. |
This example displays voltage sensor statistics:
Server# scope sensor Server /sensor # show voltage Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ P3V_BAT_SCALED Normal 3.022 V N/A N/A 2.798 3.088 P12V_SCALED Normal 12.154 V N/A N/A 11.623 12.331 P5V_SCALED Normal 5.036 V N/A N/A 4.844 5.157 P3V3_SCALED Normal 3.318 V N/A N/A 3.191 3.381 P5V_STBY_SCALED Normal 5.109 V N/A N/A 4.844 5.157 PV_VCCP_CPU1 Normal 0.950 V N/A N/A 0.725 1.391 PV_VCCP_CPU2 Normal 0.891 V N/A N/A 0.725 1.391 P1V5_DDR3_CPU1 Normal 1.499 V N/A N/A 1.450 1.548 P1V5_DDR3_CPU2 Normal 1.499 V N/A N/A 1.450 1.548 P1V1_IOH Normal 1.087 V N/A N/A 1.068 1.136 P1V8_AUX Normal 1.773 V N/A N/A 1.744 1.852 Server /sensor #
Viewing Current Sensors
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope sensor | Enters sensor command mode. |
| Step 2 | Server /sensor # show current [detail] | Displays current sensor statistics for the server. |
This example displays current sensor statistics:
Server# scope sensor Server /sensor # show current Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ VR_P2_IMON Normal 16.00 AMP N/A 147.20 N/A 164.80 VR_P1_IMON Normal 27.20 AMP N/A 147.20 N/A 164.80 Server /sensor #
Viewing Storage Sensors
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters chassis command mode. |
| Step 2 | Server /chassis # show hdd [detail] | Displays storage sensor information. |
| Name | Description |
|---|---|
| Name column |
The name of the storage device. |
| Status column |
The status of the device. This can be: |
This example displays storage sensor information:
Server# scope chassis Server /chassis # show hdd Name Status -------------------- -------------------- HDD_01_STATUS present HDD_02_STATUS present HDD_03_STATUS present HDD_04_STATUS present Server /chassis #