- Preface
- Overview
- Managing the Server
- Viewing Server Properties
- Viewing Server Sensors
- Managing Remote Presence
- Managing User Accounts
- Configuring Network-Related Settings
- Managing Network Adapters
- Configuring Communication Services
- Managing Certificates
- Configuring Platform Event Filters
- CIMC Firmware Management
- Viewing Logs
- Server Utilities
- Index
Viewing Server Properties
This chapter includes the following sections:
- Viewing CPU Properties
- Viewing Memory Properties
- Viewing Power Supply Properties
- Viewing Storage Properties
- Viewing PCI Adapter Properties
Viewing CPU Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters chassis command mode. |
| Step 2 | Server /chassis # show cpu [detail] | Displays CPU properties. |
This example displays CPU properties:
Server# scope chassis Server /chassis # show cpu Name Cores Version ------------ -------- -------------------------------------------------- CPU1 4 Intel(R) Xeon(R) CPU E5520 @ 2.27GHz CPU2 4 Intel(R) Xeon(R) CPU E5520 @ 2.27GHz Server /chassis #
Viewing Memory Properties
The server must be powered on, or the properties will not display.
This example displays memory properties:
Server# scope chassis Server /chassis # show dimm Name Capacity Channel Speed (MHz) Channel Type -------------------- --------------- ------------------- --------------- DIMM_A1 2048 MB 1067 Other DIMM_A2 2048 MB 1067 Other DIMM_B1 2048 MB 1067 Other DIMM_B2 2048 MB 1067 Other DIMM_C1 Not Installed Unknown Other DIMM_C2 Not Installed Unknown Other DIMM_D1 2048 MB 1067 Other DIMM_D2 2048 MB 1067 Other DIMM_E1 2048 MB 1067 Other DIMM_E2 2048 MB 1067 Other DIMM_F1 Not Installed Unknown Other DIMM_F2 Not Installed Unknown Other Server /chassis #
This example displays detailed information about memory properties:
Server# scope chassis
Server /chassis # show dimm detail
Name DIMM_A1:
Capacity: 2048 MB
Channel Speed (MHz): 1067
Channel Type: Other
Memory Type Detail: Synchronous
Bank Locator: NODE 0 CHANNEL 0 DIMM 0
Visibility: Yes
Operability: Operable
Manufacturer: 0x802C
Part Number: 18JSF25672PY-1G1D1
Serial Number: 0xDA415F3F
Asset Tag: Unknown
Data Width: 64 bits
Name DIMM_A2:
Capacity: 2048 MB
--More--
Server /chassis #
This example displays DIMM summary information:
Server# scope chassis
Server /chassis # show dimm-summary
DIMM Summary:
Memory Speed: 1067 MHz
Total Memory: 16384 MB
Effective Memory: 16384 MB
Redundant Memory: 0 MB
Failed Memory: 0 MB
Ignored Memory: 0 MB
Number of Ignored Dimms: 0
Number of Failed Dimms: 0
Memory RAS possible: Memory configuration can support mirroring
Memory Configuration: Maximum Performance
Server /chassis #
Viewing Power Supply Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters chassis command mode. |
| Step 2 | Server /chassis # show psu [detail] | Displays power supply properties. |
This example displays power supply properties:
Server# scope chassis Server /chassis # show psu Name In. Power (Watts) Out. Power (Watts) Firmware Status ---------- -------------------- -------------------- -------- ---------- PSU1 74 650 R0E Present PSU2 83 650 R0E Present Server /chassis #
Viewing Storage Properties
Viewing Storage Adapter Properties
The server must be powered on, or the properties will not display.
This example displays storage properties:
Server# scope chassis
Server /chassis # show storageadapter
PCI Slot Product Name Serial Number Firmware Package Build
-------- ---------------------------------- -------------- -------------------------
SAS LSI MegaRAID SAS 9260-8i SV93404392 12.12.0-0038
Product ID Battery Status Cache Memory Size
---- -------------- -------------- --------------
LSI Logic fully charged 0 MB
Server /chassis #
This example displays battery backup unit information for the storage card named SAS:
Server# scope chassis Server /chassis # scope storageadapter SAS Server /chassis/storageadapter # show bbu Controller Battery Type Battery Present Voltage Current Charge Charging State ---------- ------------ --------------- ---------- ---------- ------ -------------- SAS iBBU true 4.051 V 0.000 A 100% fully charged Server /chassis/storageadapter #
Viewing the Flexible Flash Controller Properties
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # show flexflash detail | (Optional) Displays the available Cisco Flexible Flash controllers. |
| Step 3 | Server /chassis # scope flexflash index | Enters the Cisco Flexible Flash controller command mode for the specified controller. At this time, the only permissible index value is FlexFlash-0. |
| Step 4 | Server /chassis/flexflash # show operational-profile detail | Displays the operational profile properties. |
This example displays the properties of the flash controller:
Server# scope chassis Server /chassis # show flexflash Controller Product Name Firmware Version Internal State Vendor ------------ ---------------- ----------------- --------------- -------- FlexFlash-0 Cisco FlexFlash 1.2 build 247 Connected Cypress Server /chassis # scope flexflash FlexFlash-0 Server /chassis # show operational-profile Primary Member Slot I/O Error Threshold Host Accessible VDs -------------------- -------------------- -------------------- slot1 100 SCU Drivers Server /chassis/flexflash #
Viewing Physical Drive Properties
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # scope storageadapter slot | Enters command mode for an installed storage card. |
| Step 3 | Server /chassis/storageadapter # show physical-drive [drive-number] [detail] | Displays physical drive information for the storage card. |
| Step 4 | Server /chassis/storageadapter # show physical-drive-count [detail] | Displays the number of physical drives on the storage card. |
| Step 5 | Server /chassis/storageadapter # scope physical-drive drive-number | Enters command mode for the specified physical drive. |
| Step 6 | Server /chassis/storageadapter/physical-drive # show general [detail] | Displays general information about the specified physical drive. |
| Step 7 | Server /chassis/storageadapter/physical-drive # show inquiry-data [detail] | Displays inquiry data about the specified physical drive. |
| Step 8 | Server /chassis/storageadapter/physical-drive # show status [detail] | Displays status information about the specified physical drive. |
This example displays general information about physical drive number 1 on the storage card named SAS:
Server# scope chassis
Server /chassis # scope storageadapter SAS
Server /chassis/storageadapter # scope physical-drive 1
Server /chassis/storageadapter/physical-drive # show general
Slot Number 1:
Controller: SAS
Enclosure Device ID: 27
Device ID: 34
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Link Speed: 6.0 Gb/s
Interface Type: SAS
Media Type: HDD
Block Size: 512
Block Count: 585937500
Raw Size: 286102 MB
Non Coerced Size: 285590 MB
Coerced Size: 285568 MB
SAS Address 0: 500000e112693fa2
SAS Address 1:
Connected Port 0:
Connected Port 1:
Connected Port 2:
Connected Port 3:
Connected Port 4:
Connected Port 5:
Connected Port 6:
Connected Port 7:
Power State: powersave
Server /chassis/storageadapter/physical-drive #
This example displays inquiry data about physical drive number 1 on the storage card named SAS:
Server# scope chassis
Server /chassis # scope storageadapter SAS
Server /chassis/storageadapter # scope physical-drive 1
Server /chassis/storageadapter/physical-drive # show inquiry-data
Slot Number 1:
Controller: SAS
Product ID: MBD2300RC
Drive Firmware: 5701
Drive Serial Number: D010P9A0016D
Server /chassis/storageadapter/physical-drive #
This example displays status information about physical drive number 1 on the storage card named SAS:
Server# scope chassis
Server /chassis # scope storageadapter SAS
Server /chassis/storageadapter # scope physical-drive 1
Server /chassis/storageadapter/physical-drive # show inquiry-data
Slot Number 1:
Controller: SAS
State: online
Online: true
Fault: false
Server /chassis/storageadapter/physical-drive #
Viewing Virtual Drive Properties
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # scope storageadapter slot | Enters command mode for an installed storage card. |
| Step 3 | Server /chassis/storageadapter # show virtual-drive [drive-number] [detail] | Displays virtual drive information for the storage card. |
| Step 4 | Server /chassis/storageadapter # show virtual-drive-count [detail] | Displays the number of virtual drives configured on the storage card. |
| Step 5 | Server /chassis/storageadapter # scope virtual-drive drive-number | Enters command mode for the specified virtual drive. |
| Step 6 | Server /chassis/storageadapter/virtual-drive # show physical-drive [detail] | Displays physical drive information about the specified virtual drive. |
This example displays information about virtual drives on the storage card named SAS:
Server# scope chassis Server /chassis # scope storageadapter SAS Server /chassis/storageadapter # show virtual-drive Virtual Drive Status Name Size RAID Level -------------- --------------- ------------------------ ---------- ---------- 0 Optimal SLES1SP1beta5 30720 MB RAID 0 1 Optimal RHEL5.5 30720 MB RAID 0 2 Optimal W2K8R2_DC 30720 MB RAID 0 3 Optimal VD_3 30720 MB RAID 0 4 Optimal ESX4.0u2 30720 MB RAID 0 5 Optimal VMs 285568 MB RAID 0 6 Optimal RHEL6-35GB 35840 MB RAID 0 7 Optimal OS_Ins_Test_DR 158720 MB RAID 0 8 Optimal 285568 MB RAID 1 Server /chassis/storageadapter #
This example displays physical drive information about virtual drive number 1 on the storage card named SAS:
Server# scope chassis Server /chassis # scope storageadapter SAS Server /chassis/storageadapter # scope virtual-drive 1 Server /chassis/storageadapter/virtual-drive # show physical-drive Span Physical Drive Status Starting Block Number Of Blocks ----- -------------- ---------- -------------- ---------------- 0 12 online 62914560 62914560 Server /chassis/storageadapter/virtual-drive #
Viewing PCI Adapter Properties
The server must be powered on, or the properties will not display.
| Command or Action | Purpose | |
|---|---|---|
| Step 1 | Server# scope chassis | Enters the chassis command mode. |
| Step 2 | Server /chassis # show pci-adapter [detail] | Displays PCI adapter properties. |
This example displays PCI adapter properties:
Server# scope chassis Server /chassis # show pci-adapter Name Slot Vendor ID Device ID Product Name ---------------- ----- ------------ ------------ ------------------------- PCIe Adapter1 1 0x1137 0x0042 Cisco UCS P81E Virtual... PCIe Adapter2 5 0x1077 0x2432 Qlogic QLE2462 4Gb dua... Server /chassis #