Bias-Free Language

The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.

Book Contents
    null
Find Matches in This Book
Log in to Save Content
Available Languages

Results

Updated:
January 8, 2018

Chapter: NX-OSv 9000

  • About NX-OSv 9000
  • NX-OSv 9000 Guidelines and Limitations
  • Benefits of Virtualization Using the NX-OSv 9000
  • NX-OSv 9000 Software Functionality
  • NX-OSv 9000 Resource Requirements
  • VMware ESXi Support Information
  • KVM-QEMU Support Information
  • VirtualBox Support Information
  • VMware Fusion Support Information
  • NX-OSv 9000 Installation/Deployment
  • NX-OSv 9000 Software Upgrade and Downgrade
  • NX-OSv 9000 Configuration
  • NX-OSv 9000 Deployment
    • Provisioning the NX-OSv 9000 in the ESXi Hypervisor
    • NX-OSv 9000 Deployment on KVM/QEMU Hypervisor
      • KVM/QEMU Environment Networking
        • Choosing a Networking Transport Type
        • Networking CLI Commands
        • Socket Transport
          • Tap and Bridge Transport
          • Connecting Two VMs
        • Simulating a Large Number of Network Interfaces on KVM/QEMU
        • NX-OSv 9000 Management Connectivity External to the KVM Hypervisor Server
    • Deploying NX-OSv 9000 on VirtualBox
      • Creating a VM in a VirtualBox Environment Using VMDK
        • Setup Serial Console on VirtualBox Environment
        • Set Up SSH Passwordless Connection to VM
      • Deploying NX-OSv 9000 on VirtualBox with Vagrant Using a Pre-Packaged Box
        • Vagrant Configuration Examples
      • Deleting the VM
  • Network Topology Examples

NX-OSv 9000

This chapter contains the following sections:

  • About NX-OSv 9000
  • NX-OSv 9000 Guidelines and Limitations
  • Benefits of Virtualization Using the NX-OSv 9000
  • NX-OSv 9000 Software Functionality
  • NX-OSv 9000 Resource Requirements
  • VMware ESXi Support Information
  • KVM-QEMU Support Information
  • VirtualBox Support Information
  • VMware Fusion Support Information
  • NX-OSv 9000 Installation/Deployment
  • NX-OSv 9000 Software Upgrade and Downgrade
  • NX-OSv 9000 Configuration
  • NX-OSv 9000 Deployment
  • Network Topology Examples

About NX-OSv 9000

The NX-OSv 9000 is a virtual platform that is designed to simulate the control plane aspects of a network element running Cisco Nexus 9000 software. The NX-OSv 9000 shares the same software image running on Cisco Nexus 9000 hardware platform although no specific hardware emulation is implemented. When the software runs as a virtual machine, line card (LC) ASIC provisioning or any interaction from the control plane to hardware ASIC is handled by the NX-OSv 9000 software data plane.

The NX-OSv 9000 for the Cisco Nexus 9000 Series provides a useful tool to enable the devops model and rapidly test changes to the infrastructure or to infrastructure automation tools. This enables customers to validate configuration changes on a simulated network prior to applying them on a production network. Some users have also expressed interest in using the simulation system for feature test ,verification, and automation tooling development and test simulation prior to deployment. NX-OSv 9000 can be used as a programmability vehicle to validate software defined networks (SDNs) and Network Function Virtualization (NFV) based solutions.

NX-OSv 9000 Guidelines and Limitations

NX-OSv 9000 has the following guidelines and limitations:

  • After initial setup of the NX-OSv 9000, you must configure the booting image in your system. Otherwise, the NX-OSv 9000 drops to the loader> prompt after reload/shut down.

    switch# configure terminal
    switch(config)#  boot nxos n9000-dk9.7.0.3.I2.0.454.bin
    switch(config)#  copy running-config startup-config
    
    
  • The NX-OSv 9000 uses vNICs that are entered from the KVM/QEMU command line or from the GUI on ESXi for networking either externally or internally within a hypervisor server. The first NIC is always used as the NX-OSv 9000 management interface. The subsequence NICs are used as data ports as e1/1, e1/2, ... e1/9. Ten NICs are allowed with nine NICs for data ports.


    Note


    Beginning with Cisco NX-OS Release 7.0(3)I5(2), a maximum of 64 data ports (e1/1, e1/2, ... e1/64) are supported.


    Connect only the first NIC for the NX-OSv 9000 VM as the management interface to your LAN physical switch or vSwitch (VM Network) connecting directly to a physical switch. Do not connect any data port vNIC to any physical switch that conflicts with your server management connectivity.

  • NX-OSv 9000 only supports the ESXi standard vSwitch when VMs are interconnected within a hypervisor or an external physical switch.

  • The vSwitch mapping to data port interface is required to have Promiscuous Mode as the Accept mode in order to pass traffic between VMs.

  • Multicast snooping should be disabled on net-devices configured as bridges on Linux-host machines. These net-devices are used to connect VMs in the NX-OSv 9000 setup.

  • The NX-OSv 9000 operates as a bridge that generates BPDU packets on its Ethernet interfaces as it participates in Spanning Tree Protocol (STP). It also forwards broadcast, unknown unicast, and multicast traffic as expected by classic bridging logic. Do not connect the NX-OSv 9000 data plane interfaces to the upstream network in a manner that would create bridging loops or interfere with upstream STP operation.
  • Beginning with Cisco NX-OS Release 7.0(3)I6(1), NX-OSv 9000 is supported in the Virtual Internet Routing Lab (VIRL) and the Cisco Modeling Lab (CML) environment running as a VM.

  • Beginning with Cisco NX-OS Release 7.0(3)I6(1), VXLAN BGP EVPN is supported on NX-OSv 9000.

Benefits of Virtualization Using the NX-OSv 9000

This virtual platform provides these virtualization benefits in a cloud environment and you are not limited to the type of hardware as well as other resources.

Benefits

Description

Hardware Independence

This virtual platform provides these virtualization benefits in a cloud environment and users is not limited to hardware as well as other resources.

Note   

The minimum RAM/memory requirement for an NX-OSv 9000 based VM is 4GB

Resource Sharing

The resources used by NX-OSv 9000 are managed by the hypervisor, and can be shared among VMs. The amount of hardware resources that VM sever allocates to a specific VM, can be reallocated to another VM on the server.

Flexibility in Deployment

You can easily move a VM from one server to another, Thus, you can move the NX-OSv 9000 from a server in one physical location to a server in another physical location without moving any hardware resources.

Dynamic Networking

Users can change network connectivity and configuration in a matter of mins without any physical cabling.

NX-OSv 9000 Software Functionality

NX-OS 7.0(3)I6(1) Release and Earlier Releases

Beginning Cisco NX-OS 7.0(3)I5(1), NX-OSv 9000 supports emulation and implementation on a subset of hardware dependent features. Enablement of such features in the forwarding plane allows users to simulate a more realistic deployment scenario such as an NX-OS hardware platform.

The following are restrictions and host environment differences for NX-OSv 9000:
  • Interface throughputs are currently rate-limited to prevent any production usage. The interface rate-limit is set as 4M per device.

  • For the Oracle VM VirtualBox hypervisor, the SATA block device must be used due to the image size increase from the 7.0(3)I5(1) branch which impacts the legacy bios IDE controller size limit. SATA block devices also significantly improve disk performance, especially for initial boot up time. The IDE controller can be used in the VMware ESXi and the KVM/QEMU hypervisor, but it is significantly slower than the SATA controller.

  • A SATA block device can also be used in KVM/QEMU hyerpvisor, but it requires QEMU 2.2.0 or later version. Similar to the Oracle VM VirtualBox hypervisor, a performance improvement can be obtained in the KVM/QEMU environment.

Supported Features

The following table displays specific Layer 2 and Layer 3 software feature support based on branch/lineup.

Table 1 Supported Layer 2 and Layer 3 Features (Software)

Technology

Branch/Lineup

Nexus Feature Name

Support Statement

Cisco NX-OS 7.0(3)I5(1), 7.0(3)I5(2), and 7.0(3)I6(1) Releases

OS Infra

Bash Shell

Supported

Guest Shell

Supported

SSH

Supported

RPM Installation

Supported

POAP

Supported for the management interface in Cisco NX-OS Release 7.0(3)I5(1) and for all interfaces in Cisco NX-OS Release 7.0(3)I5(2) and Cisco NX-OS Release 7.0(3)I6(1)

Programmability

NXAPI

Supported

Puppet Integration (Native)

Supported

Puppet Integration (Guest Shell)

Supported

Chef Integration (Native)

Supported

Chef Integration (Guest Shell)

Supported

L3 Features

CDP

Supported

LLDP

Supported

BGP v4

Supported (No BFD, EVPN)

Note   

VXLAN EVPN is supported in Release7.0(3)I6(1) and later.

BGP v6

Supported (No BFD, EVPN)

OSPFv2

Supported (No BFD, EVPN)

OSPFv3

Supported (No BFD, EVPN)

EIGRP

Supported

RIP

Supported

L2 Features

L2 Switching Unicast

Supported

L2 Switching Broadcast

Supported

L2 Switching Multicast

Supported as Broadcast (not explicit Mcast) , No PIM or Mcast Group support

MAC learning

Supported

Static/Router MAC

Supported

Switchport

Supported

1. 802.1q Trunk

Supported

2. 802.1q Access

Supported

STP

Supported

L3 SVI

Supported

Subinterfaces

Supported

VXLAN

Supported (Flood and Learn); BGP EVPN without ARP suppression in Cisco NX-OS Release 7.0(3)I6(1) and later.

vPC

Not supported in Cisco NX-OS Release 7.0(3)I5(1), but supported in Cisco NX-OS Release 7.0(3)I5(2) and Cisco NX-OS Release 7.0(3)I6(1)

Port channel

Supported


Note


The NX-OSv 9000 features in this table have been verified to operate only with the Cisco devices mentioned in this document.


If a networking or system feature is not identified as a supported feature in this document, it should be considered as unsupported despite that it may seem to work correctly. Unsupported features did not have any level of regression testing on NX-OSv 9000.

Table 2 NX-OS Features Not Supported (Not Tested)

NX-OS Features

Limitations

QoS

Not supported on NX-OSv 9000.

BFD

Not supported on NX-OSv 9000.

ACL

Not supported on NX-OSv 9000.

Policy maps

Not supported on NX-OSv 9000.

ARP Suppression

Not supported on NX-OSv 9000.

SPAN

Not supported on NX-OSv 9000.

IGMP Snooping

Not supported on NX-OSv 9000.

AMT

Not supported on NX-OSv 9000.

LISP

Not supported on NX-OSv 9000.

OTV

Not supported on NX-OSv 9000.

The following list (not comprehensive) contains known system limitations.

Table 3 NX-OS System Limitations

System Capabilities

Limitations

MAC Address

NX-OSv 9000 does not integrate the L2FM module and L2FDWR data plane. It maintains its own MAC Table. Therefore the behavior of the MAC address related CLIs will be different from the physical platform.

Statistics

NX-OSv 9000 re-uses a software data plane that was created for L2FDWR. With this data plane, NX-OSv 9000 will not be able to account for and display traffic related statistics (such as interface statistics).

Consistency Checker

The consistency checker has a hardware dependency and hence is not supported on NX-OSv 9000. All ‘show’ and ‘exec’ commands will result with appropriate error/warnings.

Network Throughput

Low data plane performance. Additional rate limiter is in place to limit the total amount of traffic received by NX-OSv 9000 to 4M.

TOR-ISSU

TOR-ISSU is not supported.

Link Status

NX-OSv 9000 virtual interfaces serve as the ‘Ethernet Ports’. The link status of these links within the NX-OS is dependent on the Hypervisor’s capability.

Link-down

Connectivity between the two ends of the interface link is simulated, hence it is important that you shut the interface in both the ends, followed by no shut at both the ends of the interface link.

NX-OSv 9000 Feature UI/CLI Difference From Hardware Platform

Feature enablement in the NX-OSv 9000 virtual platform is the same as Cisco Nexus 9000 hardware platform.

For example, the following features can be enabled:

  • feature telnet

  • feature bash-shell

  • feature ospf

  • feature bgp

  • feature interface-vlan

  • feature nv overlay

However, not all commands are available for NX-OSv 9000, such as hardware data plane specific commands. Some of these commands exist in the command parse chain, but these commands might not display correct output information. It is not possible for the virtual platform to verify all commands on NX-OSv 9000 that exist for the Cisco Nexus 9000 hardware platform.

A few commands are critical for NX-OSv 9000 to display Layer 2/Layer 3 information, but are not provided for the NX-OSv 9000 platform. The following displays substitute commands:

NX-OS Hardware Platform Commands

Substitute for NX-OSv 9000

show mac address-table

show system internal l2fwder mac

clear mac address-table

clear mac address-table datapath static|dynamic

NX-OSv 9000 Resource Requirements

The NX-OSv 9000 uses the Cisco Nexus 9000 Series hardware software image. It requires the minimum resources as shown in the following list. These resources are generally not oversubscribed on any server.

  • 8G memory

  • Minimum 4G. We recommend a 8G VM configuration for complex topology and enabling features.

  • 1-4 vCPUs

  • 4G hard disk

  • 1 serial port

  • 1 network interface card (NIC)

Server Software Requirements

The NX-OSv 9000 can run on Cisco Unified Computing System (UCS) servers or servers from leading vendors that support VMware ESXi 5.1 (Post Build 1065491/ ESXi 5.5) or the combination of Ubuntu Linux 14.04LTS or later version and KVM-QEMU 2.0.

if you only need a standalone NX-OSv 9000 node, the NX-OSv 9000 can also be deployed on a laptop or and Apple Mac Pro with a virtual box hypervisor as long as your laptop meets basic resource requirements.

VMware ESXi Support Information

The virtual machine (VM) runs on the VMware vSphere Hypervisor. You can use the same VMware vSphere hypervisor to run serial VMs. Use the VMware vSphere Client GUI to create and manager VMs.

The VMware vSphere Client is an application for creating, configuring, and managing VMs on the VMware vCenter Server. The NX-OSv 9000 can boot from a virtual disk located on the data store. You can perform basic administration tasks such as starting and stopping the NX-OSv 9000, using the VMware vSphere Client.

VMWare vCenter Server manages the vSphere environment and provides unified management of all the hosts and VMs in the data center from a single console.

For more information about how Cisco and VMware work together, see http:/​/​www.vmware.com/​cisco.

For more information about VMware features and operations, see the https:/​/​www.vmware.com/​support/​pubs/​.

KVM-QEMU Support Information

The kernel-based Virtual Machine (KVM) is an open-source, full-virtualization solution for Linux on x86 hardware, containing virtualization extensions. It consists of a loadable kernel module, kvm.ko, that provides the core virtualization infrastructure and a processor-specific module, ivm-intel.ko or kvm-amd.ko

Quick Emulator (QEMU) is a free and open-source software product that performs hardware virtualization. You can run QEMU on the Cisco UCS server with KVM installed. The recommended version of QEMU for the NX-OSv 9000 reference platform is version 2.2.0 or later.

VirtualBox Support Information

VirtualBox is a powerful x86 and AMD64/Intel 64 virtualization product for enterprise as well as for the home user. It is free software available as Open Source Software under the terms of the GNU General Public License (GPL) version 2 and you can obtain more information and download from https:/​/​www.virtualbox.org/​ web site.

VMware Fusion Support Information

VMware Fusion is also a powerful virtualization product for enterprise as well as PC user.

NX-OSv 9000 Installation/Deployment

NX-OSv 9000 currently does not support virtio block disk. To optimize performance, specific virtual artifact formats are recommended to be used in particular hypervisor.

Hypervisor

Virtual Artifact Format

EXSi

Virtual Machine Disk Image (vmdk), Open Virtualization Appliance (ova)

KVM/Qemu

QEMU Copy On Write (qcow2),Open Virtualization Appliance (ova)

Virtual Box

Virtual Machine Disk Image (vmdk), or packaged box

VMware Fusion

Open Virtualization Appliance (ova)

NX-OSv 9000 Software Upgrade and Downgrade

The software upgrade and downgrade of NX-OSv 9000 does not follow normal hardware platform procedures. A common upgrade method for NX-OSv 9000 is to tftp or scp a new image into the bootflash, then boot the new image from the loader> prompt or set the boot image in "config t; boot nxos bootflash:new_image.bin". A similar approach is used for downgrade.


Note


This approach requires sufficient bootflash disk space to hold another image. As such, the nxos.7.0.3.I2.2a image is not upgradable to a new release. In this case, you can create a new VM based on the nxosv-final.7.0.3.I2.2d release; and then upgrade to a new release.


NX-OSv 9000 Configuration

Beginning with Cisco NX-OS Release 7.0(3)I5(2), Cisco NX-OSv 9000 supports the Cisco Virtual Appliance Configuration (CVAC). This out-of-band configuration mechanism is similar to the POAP autoconfiguration, but instead of downloading the configuration across the network as POAP does, CVAC receives the configuration injected into the Cisco NX-OSv 9000 environment on a CD-ROM. The configuration is detected and applied at startup time.

CVAC can be used for a bootstrap configuration (supplying just enough configuration to bring the switch into a reachable state suitable for subsequent configuration using Telnet, RESTful APIs, or other standard mechanisms) or a full configuration (taking the entire configuration of another router and replicating it into a newly launched platform VM). The configuration should be in a plain-text file called nxos_config.txt. You can package the configuration file onto the CD-ROM using the following command:

mkisofs -output nxosconfig.iso -l --relaxed-filenames --iso-level 2 <file(s) to add>

If the system does not detect a CVAC configuration, the POAP process begins, and the POAP interface prompts you for the initial installation. See PowerOn Auto Provisioning for a newly installed switch.

The Cisco NX-OSv 9000 supports the same control plane features and configuration that are supported on the Cisco Nexus 9000 Series hardware platforms. The configuration commands for the control plane features follow the same syntax as the Cisco Nexus 9000 Series switches.

NX-OSv 9000 Deployment

  • Provisioning the NX-OSv 9000 in the ESXi Hypervisor
  • NX-OSv 9000 Deployment on KVM/QEMU Hypervisor
  • Deploying NX-OSv 9000 on VirtualBox

Provisioning the NX-OSv 9000 in the ESXi Hypervisor

Before You Begin

You must have already installed your ESXi hypervisor.


    Step 1   Log into the VMware vSphere Client.

    Step 2   Select your server's IP address and click the Create a new virtual machine link.
    Step 3   In the Configuration screen, click the Custom button and click Next.
    Step 4   In the Name and Location screen, enter your virtual machine's name and click Next.
    Step 5   In the Storage screen, select the datastore and click Next.
    Step 6   In the Virtual Machine Version screen, choose the Virtual Machine Version button and click Next.
    Step 7   In the Guest Operating System screen, choose Other (64-bit), Version, and click Next.
    Step 8   In the CPUs screen, choose Number of cores per virtual socket value and click Next.
    Step 9   In the Memory screen, enter the memory size and click Next.
    Note   

    The minimum size is 4 GB, but the preferable size is 8 GB.

    Step 10   In the Network screen, select the number of NICs you want to connect.
    Note   

    The first NIC must be the management interface. Do not connect all dataports to the management interface.

    Step 11   In the SCSI Controller screen, choose your SCSI controller, and click Next.
    Step 12   In the Select a disk screen, choose the Use an existing virtual disk button, and click Next.
    Step 13   In the Select Existing Disk screen:
    1. Browse to the location of the n9000v-dk9-final.7.0.3.I2.1.vmdk file and click OK.
    2. Click Next.
    Step 14   In the Advanced Options screen, confirm that the Virtual Device Node is IDE (0:0), and click Next.
    Step 15   In the Ready to Complete screen, chose the Edit the virtual machine settings before completion check box, and click Continue.
    Step 16   In the Virtual Machine Properites screen, click the Add button to add a Serial Port, confirm that the Virtual Device Node is IDE (0:0), and click Next.
    Step 17   In the Device Type screen, choose Serial Port and click Next.
    Step 18   In the Serial Port Type screen, choose the Connect via Network button, and click Next.
    Step 19   In the Network Serial Port Settings screen:
    1. In the Network Backing frame, choose the Server button.
    2. Enter telnet and the server IP address in the Port URI field, and click Next.
    Step 20   In the Ready to Complete screen, click Finish.
    Step 21   In the Getting Started tab, click the Edit virtual machine settings link.
    Step 22   In the vSphere Client, select the name of the virtual machine and click the Options tab.
    Step 23   In the Virtual Machine Properties screen, choose Boot Options in the Setting column.
    Step 24   In the Firmware panel, choose the EFI button and click OK.
    Step 25   Power on the virtual machine.

    NX-OSv 9000 Deployment on KVM/QEMU Hypervisor

    The NX-OSv 9000 can be brought up in the KVM/QEMU hypervisor. The following table lists the parameters that are supported for the NX-OSv 9000 deployment on KVM/QEMU.

    Parameter

    Example

    Description

    /path_to/qemu

    /usr/bin/qemu-system-x86_64

    Path to QEMU executable. (The QEMU software can be downloaded from http:/​/​wiki.qemu.org/​download for different versions.)

    -nographic

    -nographic

    Recommended, as the NX-OSv 9000 does not support VGA.

    -bios file

    -bios bios.bin

    Required. The NX-OSv 9000 uses EFI boot and requires a compatible BIOS image to operate.

    We recommend using the latest OVMF BIOS file with the SATA controller for better performance in terms of disk operation. QEMU 2.6 is recommended with the SATA controller. For more information, see http:/​/​www.linux-kvm.org/​page/​OVMF.

    -smp

    -smp 4

    The NX-OSv 9000 supports one to four vCPUs, but two to four are recommended.

    -m memory

    -m 8096

    Minimum memory is required.

    -serial telnet:host:port,server,nowait

    -serial telnet:localhost:8888,server,nowait

    or

    -serial telnet:server_ip:8888,server,nowait

    Requires at least one.

    -net ... -net ...

    or

    -netdev ... -device ...

    -net socket,vlan=x,name=nl_s0,listen=localhost:12000

    -net nic, vlan=x,model=e1000,macaddr=aaaa.bbbb.cccc

    -netdev socket,listen=localhost:12000,id=eth_s_f

    -device e1000,addr=s.f,netdev=eth_s_f,

    mac=aaaa.bbbb.cccc,multifunction=on,romfile=

    or

    -netdev tap,ifname=tap_s_f,script=no,

    downscript=no,id=eth_s_f

    -device e1000,addr=s.f,netdev=eth_s_f,

    mac=aaaa.bbbb.ccc,multifunction=on,romfile=

    The net/net or netdev/device pairs are for networking a virtual network interface card (vNIC).

    The _s_f represents the PCI slot number and function number. QEMU 2.0 or above has the capability to plug in at least 20 PCI slots and four functions, which accommodates about 80 vNICs in total. The slot range is from 3 to 19, and the function number range is from 0 to 3.

    The mac= option passes the MAC address of each vNIC MAC address to the VM interfaces. The first -netdev is automatically mapped to the mgmt0 interface on the VM. The second -netdev is mapped to the e1/1 interface and so on up to the sixty-fifth on e1/64. Make sure these MAC addresses are unique for each network device.

    -enable-kvm

    -enable-kvm

    This flag is required for the NX-OSv 9000.

    -drive ... -device ... (for the SATA controller)

    -device ahci,id=ahci0,bus=pci.0

    -drive file=img.qcow2,if=none,id=drive-sata-disk0,format=qcow2

    -device ide-drive,bus=ahci0.0,drive=drive-sata-disk0,id=drive-sata-disk0

    Format to use the SATA controller. We recommend using the SATA controller with QEMU 2.6.0 because this controller offers better performance than the IDE controller. However, you can use the IDE controller if you have an early QEMU version that does not support the SATA controller.

    -drive ... -device .... (for the IDE controller)

    -drive file=img.qcow2,if=none,id=drive-ide0-0-0,format=qcow2

    -device ide-hd,bus=ide.0,unit=1,drive=drive-ide0-0-0,id=ide0-0-0

    Format to use the IDE controller.

    -drive ... media=cdrom

    -drive file=cfg.iso,media=cdrom

    CD-ROM disk containing a switch configuration file that will be applied after the NX-OSv 9000 comes up.

    1. Name a text file (nxos_config.txt).

    2. Use Linux commands to make cfg.iso, mkisofs -o cfg.iso -l --iso-level 2 nxos_config.txt.

    KVM/QEMU Environment Networking

    • Choosing a Networking Transport Type
    • Networking CLI Commands
    • Socket Transport
    • Simulating a Large Number of Network Interfaces on KVM/QEMU
    • NX-OSv 9000 Management Connectivity External to the KVM Hypervisor Server
    Choosing a Networking Transport Type

    QEMU/KVM supports several different VM network transport types:

    • Socket transport

    • Tap and bridge transport

    • User transport

    Each type has advantages and disadvantages. Depending on your host access and the devices or networks to which you wish to connect your VM, some transports may be more convenient than others.

    Table 4 Transport Type Advantages and Disadvantages

    Transport Type

    Advantages

    Disadvantages

    Socket

    • Does not require sudo/root access to set up

    • Decent performance

    • Only point-to-point connectivity is possible (no LAN capability)

    • Must bring up VMs in order ("listen" socket before "connect")

    • Can lose connectivity if VMs are stopped and restarted

    • Can connect only to other VMs, not to a host or lab network

    Tap and bridge

    • Can connect multiple VMs to a single LAN

    • Can connect VMs to a host or to other devices on your lab network

    • Can run tcpdump (or Wireshark) to capture traffic on tap interfaces

    • Generally the best performance

    • Requires sudo/root access to create taps and bridges

    • Misconfiguration can render the host unreachable, requiring a reboot of the host

    User

    • Does not require sudo/root access to set up

    • Can connect VMs to a host

    • Very slow performance

    • Some protocols (for example, ICMP and ping) are not supported

    • Cannot connect to a lab network or to other VMs, only to a host

    General guidelines:

    • If you have root access to create taps and bridges, tap and bridge transport is the most flexible and powerful transport type, but it requires caution during setup.

    • If you do not have root access and want to interconnect VMs, socket transport is the fallback option.

    • If you do not have root access and want to connect the VM to the host, user transport will work but has limitations.

    • If you have no need for network connectivity, you do not need a transport at all (see Networking CLI Commands).

    Networking CLI Commands

    You have two ways to add NICs using the QEMU CLI. One (-net/-net) is simpler but officially deprecated. The other (-netdev/-device) is the current recommendation but is slightly more complex. In both cases, two QEMU commands are required per NIC. One defines the NIC's appearance to the NX-OSv 9000 (primarily its MAC address), and the other defines the underlying transport mechanism.

    Task

    Old CLI

    New CLI

    Create NIC

    -net nic,model=model,vlan=number,macaddr=macaddr

    Note   

    Typical values for model when using the old CLI are virtio or e1000.

    -device model,netdev=string,macaddr=macaddr

    Note   

    Typical values for model when using the new CLI are virtio-net-pci or e1000.

    Define network transport for NIC

    -net transport,options,vlan=number

    -netdev transport,options,id=string

    If your VM does not require connectivity to other hosts or VMs, you can omit the -net transport... or -netdev transport... commands entirely. As a result, NICs are visible to the guest and configurable for testing but do not pass packets.

    With the old CLI, the vlan=number parameter is used to link the two commands together. (Both commands for a NIC should use the same number.) With the new CLI, the netdev=string and id=string parameters serve this purpose. (The string values must match.)

    Socket Transport

    Point-to-point connections between VMs can use TCP sockets as the transport mechanism. One VM will open a listen socket, and the other VM will connect to this socket.

    Task

    Old CLI

    New CLI

    First VM

    -net socket,listen=host1:port,...

    -netdev socket,listen=host1:port,...

    Second VM

    -net socket,connect=host1:port,...

    -netdev socket,connect=host1:port,...

    In socket transport, the listen VM must be started before the connect VM; otherwise, the connection between VMs will not be successfully established. Similarly, if the listen VM is terminated and relaunched, you might need to terminate and relaunch the connect VM, which can be challenging in complex topologies.


    Note


    In QEMU versions prior to 1.4, you cannot use -netdev socket as it will fail with the following error: Property 'model.netdev' can't find value 'netdev'. If you are using QEMU 1.0 or 1.2.x, you must use -net for socket transports.


    • Tap and Bridge Transport
    • Connecting Two VMs
    Tap and Bridge Transport

    The host can provide tap interfaces connected to a virtual bridge in order to provide LAN connectivity between multiple VMs. Each VM NIC uses an individual tap interface as its designated transport, and the host connects the taps to a shared bridge as needed.

    The bringup-script and teardown-script parameters are pointers to scripts used to dynamically create and tear down the tap interfaces. If you are using previously created tap interfaces, set these parameters to "no" to indicate that no such script is needed.

    You can use the tcpdump command to capture traffic on tap interfaces, which can be very useful for troubleshooting.

    Connecting Two VMs

    You can connect VMs to each other by adding the appropriate tap interfaces for each VM to a logical Ethernet bridge.

    Before You Begin

    You need sudo access to run the commands in this procedure.

       Command or ActionPurpose
      Step 1openvpn --mktun --dev


      Example:
      sudo openvpn --mktun --dev mytap0
      sudo openvpn --mktun --dev mytap1
      sudo ifconfig mytap0 up
      sudo ifconfig mytap1 up
       

      Creates two tap interfaces.

       
      Step 2brctl addbr bridge-name


      Example:
      $ sudo brctl addbr mybridge0
       

      Creates a bridge.

       
      Step 3brctl addif bridge-name tap-name


      Example:
      $ sudo brctl addif mybridge0 mytap0
      $ sudo brctl addif mybridge0 mytap1
       

      Adds tap interfaces to the bridge.

       
      Step 4ifconfig bridgename up


      Example:
      $ sudo ifconfig mybridge0 up
       

      Ensures that the bridge is up and running to bridge the traffic.

       
      Step 5brctl show


      Example:
      bridge name  bridge id           STP enabled   interfaces
      mybridge0    8000.1217b6e4a8f3   no            mytap0 mytap1
      $
      
       

      Verifies the bridge setup.

       
      Step 6qemu-system-x86_64


      Example:
      $ qemu-system-x86_64 ... -net tap,ifname=mytap0,script=no,downscript=no & 
      $ qemu-system-x86_64 ... -net tap,ifname=mytap1,script=no,downscript=no &
      

      or

      $ qemu-system-x86_64 ... -netdev tap,id=mytap0,ifname=mytap0,script=no,downscript=no \  -device e1000,netdev=mytap0,mac=00:10:20:30:40:50 &
      $ qemu-system-x86_64 ... -netdev tap,id=mytap1,ifname=mytap1,script=no,downscript=no \  -device e1000,netdev=mytap1,mac=00:11:22:33:44:55 &
      
       

      Starts VMs using tap transport.

       
      Simulating a Large Number of Network Interfaces on KVM/QEMU

      You can increase the number of network interfaces for a guest VM by specifying the PCI address in the -device option.

      In the following example, users should have 1+2 network interfaces in the NX-OSv 9000 guest. The first vNIC maps to the NX-OSv 9000 management interface. The second and third vNICs map to the NX-OSv 9000 e1/1 and e1/2 data ports, respectively.


      Note


      Make sure that you download the latest BIOS image as well as QEMU 2.2 or a later version when you use the following examples.


      VM1

      qemu-system-x86_64 -smp 4 -enable-kvm -m 8192 -bios -nographic -serial telnet:localhost 12000,server,nowait \
      
         -netdevice  socket,listen=locahost:13000,id=eth_3_0 -device e1000,addr=3.0,netdevice=eth_3_0,mac=00:01:80:ff:00:00 \
      
         -netdevice  socket,listen=locahost:13001,id=eth_3_1 -device e1000,addr=3.1,netdevice=eth_3_1,mac=00:01:80:ff:00:01 \
      
         -netdevice  socket,listen=locahost:13002,id=eth_3_2 -device e1000,addr=3.2,netdevice=eth_3_2,mac=00:01:80:ff:00:02 \
      
         -device ahci,id=ahci0,bus=pci.0 -drive file=r1.nxosv-final.7.0.3.I5.1.qcow2,if=none,id=drive-sata-disk0,id=drive-sata-disk0,format=qcow2 \
      
         -device ide-drive,bus=ahci0.0,drive=drive-sata-disk0,id=drive-sata-disk0
      
      

      VM2

      qemu-system-x86_64 -smp 4 -enable-kvm -m 8192 -bios bios.bin -nographic -serial telnet:localhost 12100, server,nowait -netdevice
      
         -netdevice  socket,connect=locahost:13000,id=eth_3_0 -device e1000,addr=3.0,netdevice=eth_3_0,mac=00:01:80:ff:00:10 \
      
         -netdevice  socket,connect=locahost:13001,id=eth_3_1 -device e1000,addr=3.1,netdevice=eth_3_1,mac=00:01:80:ff:00:11 \
      
         -netdevice  socket,connect=locahost:13002,id=eth_3_2 -device e1000,addr=3.2,netdevice=eth_3_2,mac=00:01:80:ff:00:12 \
      
         -device ahci,id=ahci0,bus=pci.0 -drive file=r2.nxosv-final.7.0.3.I5.1.qcow2,if=none,id=drive-sata-disk0,id=drive-sata-disk0,format=qcow2 \
      
         -device ide-drive,bus=ahci0.0,drive=drive-sata-disk0,id=drive-sata-disk0
      
      NX-OSv 9000 Management Connectivity External to the KVM Hypervisor Server

      The general approach to having VM connectivity to outside the device is to pass a tap (in QEMU/KVM command invocation) that is connected to a physical interface on the server through a bridge. The first tap interface -netdev in QEMU/KVM command invocation is mapped to the management interface on VM, mgmt0. We recommend using the secondary physical port in the KVM server instead of the primary physical port, which services the connectivity to this device. Doing so will prevent connectivity issues from the server to any users.

      The following example shows how to connect the VM management interface using net device eth1 in the KVM hypervisor.

      Creating a management bridge that is attached to physical interface net device eth1 in the server:

      sudo brctl addbr mgmt_br0
      sudo brctl addif mgmt_br0 eth1
      sudo ifconfig eth1 0.0.0.0 up
      sudo ifconfig mgmt_br0 <ip> netmask 255.255.255.0 up
      sudo ifconfig eth1 up
      sudo route add default <gateway ip> mgmt_br0
      
      

      Creating a tap that is used for the -netdev parameter in the QEMU command invocation:

      sudo openvpn --mktun --dev tap_net1
      sudo brctl addif mgmt_br0 tap_net1
      sudo ifconfig tap_net1 up

      Deploying NX-OSv 9000 on VirtualBox

      NX-OSv 9000 deployment on VirtualBox uses one of two forms of distributed virtual artifacts: VMDK or Pre-packaged Box. The simplest method is to use Pre-packaged Box along with Vagrant software. However, the box is created for simple standalone VM deployment with very minimal configuration. This procedure is covered in Deploying NX-OSv 9000 on VirtualBox with Vagrant Using a Pre-Packaged Box.

      Some basic steps and concepts are shown here to create a virtual machine similar to other kinds of VM guests. These instructions are generally for Mac users, but slight differences are highlighted for Window users.

      • Creating a VM in a VirtualBox Environment Using VMDK
      • Deploying NX-OSv 9000 on VirtualBox with Vagrant Using a Pre-Packaged Box
      • Deleting the VM

      Creating a VM in a VirtualBox Environment Using VMDK

      Before You Begin
      Hardware
      • More than 12 GB of memory.

      • More than 4 cores of CPU.

      Software
      • Mac OS X

        • Install VirtualBox

        • Install Vagrant

        • Install socat for serial console:

          Homebrew:
            ruby -e "$(curl -fsSL https://raw.githubusercontent.com/Homebrew/install/master/install)"
          socat:
            brew install socat
          
          
      • Windows

        • Install VirtualBox

        • Install Vagrant

        • Install PuTTY for serial console. (For more information, see www.putty.org.)

        • Install Git to access tools, such as SSH. (For more information, see www.git-for-windows.github.io.)

         Command or ActionPurpose
        Step 1Copy VMDK to your local hard drive. Launch VirtualBox and click the New icon.
         
         
        Step 2Enter the Name as n9kv, select the Type as Linux, and select the Version as Other Linux (64-bit).
         
         
        Step 3Enter the Memory size (RAM) as 8192 MB.
         
         
        Step 4Select Use an existing virtual hard drive file. Click the folder icon (bottom right side) and select the VMDK created in step 1.
         
         
        Step 5Select your VM and click Settings.
         
         
        Step 6In the Attributes of Settings, highlight the IDE controller. Select Add SATA controller and add the VMDK file. Click OK to save the settings.
         
        Note   

        Adding the SATA controller enables VirtualBox to boot when the system image size exceeds 512 MB.

         
        Step 7Click the System icon.
        • On the Motherboard tab:

          • Check the Enable EFI checkbox.

          • Ensure the Modify Boot order so that hard disk is first.

        • On the Processor tab:

          • Ensure the Processor is 2.

        • On the Accelerator tab:

          • Ensure that VT-x/AMD-V is checked.

         
         
        Step 8Click the Audio icon. Uncheck the Enable Audio checkbox.
         
         
        Step 9Click the Network icon.
        • On the Adapter 1 tab:

          • Check the Enable Network Adapter checkbox.

          • Ensure the Port Forwarding configuration is:

            • Name = ssh

            • Host Port = 2222

            • Guest Port = 22

         
         
        Step 10Click the Ports icon.
        • On the Serial Ports tab/Port 1 tab:

          • Check the Enable Serial Port checkbox.

          • Ensure that Port Mode is Host Pipe.

          • Check Create Pipe (or uncheck Connect to existing pipe/socket).

          • Ensure Port/File Path is /tmp/test.

         
        Note   

        For Windows, on the Serial Ports tab/Port 1 tab:

        • Ensure Path/Address is \\.\pipe\COM1.
         
        Step 11Click the Ports icon.
        • On the USB tab:

          • Uncheck the Enable USB 2.0 (EHCI) controller checkbox.

         
         
        Step 12Click the Start button.
         

        Starts the VM.

        Note   

        Ensure that you have the proper serial console setup in your Mac or Windows environment. For more information, see Setup Serial Console on VirtualBox Environment.

         
        Setup Serial Console on VirtualBox Environment

        Mac OS X
        1. Use the 'socat' utility to connect to the serial port (console access) of the VM.

          1. Install Homebrew and then use homebrew to install 'socat'.

            Homebrew:
              ruby -e "$(curl -fsSL https://raw.githubusercontent.com/Homebrew/install/master/install)"
            socat:
              brew install socat
            
          2. Run the socat command from an xterm.

            socat unix-connect:/tmp/test stdin
            
        2. Go through the NXOS boot process.

          1. Answer 'no' for the secure password.

          2. Set admin password to 'admin'.

        3. Configure the router.

          switch# conf t
          Enter configuration commands, one per line. End with CNTL/Z.
          switch(config)# interface mgmt0
          switch(config-if)# ip address 10.0.2.15/24  <--- NOTE: can use "ip address dhcp" here instead
          switch(config-if)# no shut
          switch(config-if)# end
          switch# conf t
          Enter configuration commands, one per line. End with CNTL/Z.
          switch(config)# username vagrant password vagrant role network-admin
          switch(config)# username vagrant shell bash
          switch(config)# boot nxos bootflash:nxos.7.0.3.I2.2d.bin  <--- Note: use correct image name from "dir" command output
          switch(config)# copy r s
          [########################################] 100%
          Copy complete.
          switch(config)#
          
        Windows
        1. Open PuTTY.

        2. Open "Basic options for your PuTTY session".

          1. Specify "\\.\pipe\COM1" for Serial line path.

          2. Select "Serial" for "Connection type".

          3. Select "9600" for "Speed".

        3. Go through the NXOS boot process.

          1. Answer 'no' for the secure password.

          2. Set admin password to 'admin'.

        4. Configure the router.

          switch# conf t
          Enter configuration commands, one per line. End with CNTL/Z.
          switch(config)# interface mgmt0
          switch(config-if)# ip address 10.0.2.15/24  <--- NOTE: can use "ip address dhcp" here instead
          switch(config-if)# no shut
          switch(config-if)# end
          switch# conf t
          Enter configuration commands, one per line. End with CNTL/Z.
          switch(config)# username vagrant password vagrant role network-admin
          switch(config)# username vagrant shell bash
          switch(config)# boot nxos bootflash:nxos.7.0.3.I2.2d.bin  <--- Note: use correct image name from "dir" command output
          switch(config)# copy r s
          [########################################] 100%
          Copy complete.
          switch(config)#
          
        Set Up SSH Passwordless Connection to VM

        Navigate to login screen and login as vagrant (password: vagrant). Place the vagrant insecure key into the 'authorized_keys' file.

        switch(config)# exit
        switch# exit
         
        User Access Verification
        switch login: vagrant
        Password:
        -bash-4.2$
        -bash-4.2$ pwd
        /var/home/vagrant
        -bash-4.2$ cd .ssh
        -bash-4.2$ pwd
        /var/home/vagrant/.ssh
        -bash-4.2$ echo 
        "ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAQEA6NF8iallvQVp22WDkTkyrtvp9eWW6A8YVr+kz4Tj
        GYe7gHzIw+niNltGEFHzD8+v1I2YJ6oXevct1YeS0o9HZyN1Q9qgCgzUFtdOKLv6IedplqoPkcmF0
        aYet2PkEDo3MlTBckFXPITAMzF8dJSIFo9D8HfdOV0IAdx4O7PtixWKn5y2hMNG0zQPyUecp4pzC
        6kivAIhyfHilFR61RGL+GPXQ2MWZWFYbAGjyiYJnAmCP3NOTd0jMZEnDkbUvxhMmBYSdETk1rRgm+
        R4LOzFUGaHqHDLKLX+FIPKcF96hrucXzcWyLbIbEgE98OHlnVYCzRdK8jlqm8tehUc9c9WhQ
        == vagrant insecure public key" > authorized_keys
        -bash-4.2$ cat authorized_keys
        ssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAQEA6NF8iallvQVp22WDkTkyrtvp9eWW6A8YVr+kz4TjG
        Ye7gHzIw+niNltGEFHzD8+v1I2YJ6oXevct1YeS0o9HZyN1Q9qgCgzUFtdOKLv6IedplqoPkcmF0a
        Yet2PkEDo3MlTBckFXPITAMzF8dJSIFo9D8HfdOV0IAdx4O7PtixWKn5y2hMNG0zQPyUecp4pzC6k
        ivAIhyfHilFR61RGL+GPXQ2MWZWFYbAGjyiYJnAmCP3NOTd0jMZEnDkbUvxhMmBYSdETk1rRgm+R4
        LOzFUGaHqHDLKLX+FIPKcF96hrucXzcWyLbIbEgE98OHlnVYCzRdK8jlqm8tehUc9c9WhQ
        == vagrant insecure public key
        -bash-4.2$
        

        Deploying NX-OSv 9000 on VirtualBox with Vagrant Using a Pre-Packaged Box


          Step 1   Open a terminal in your Mac or PC (GitBash) and make a directory (for example, box-test).
          Step 2   Download a released image to this directory (for example, nxosv-final.7.0.3.I2.2d.box).
          Step 3   Execute "vagrant init".
          Step 4   Execute "tar xvd nxosv-final.7.0.3.I2.2d.box nxosv_config.iso" to unpack the NX-OSv switch configuration file. (The nxosv_config.iso file packaged with this .box file is for demonstration purposes. You can customize your own configuration based on CVAC/bootstrap procedures to make your own .iso configuration file.)
          Step 5   Execute "vagrant box add box-test nxosv-final.7.0.3.I2.2d.box".
          Step 6   Modify the ./Vagrant file to customize all VM configurations. See Vagrant Configuration Examples.
          Step 7   Bring up the VM using the "vagrant up" command in the current directory.
          Step 8   Wait for a few minutes to let the bootup finish. Then proceed to the next step.
          Step 9   Execute "vagrant ssh" to access the NX-OSv bash shell and enter "vagrant" for the password. If "vagrant ssh" fails, go to step 12 (serial console window) to determine the reason for the failure.
          Step 10   Execute "su admin" to access the CLI and enter "admin" or the password.
          Step 11   Execute the boot image command: "config t; boot nxos bootflash:nxos.7.0.3.I2.2d.bin".
          Step 12   Save the configuration using "copy r s".
          Step 13   You can monitor the booting process from the serial console using "socat UNIX-CONNECT:/tmp/test STDIN" in another terminal. For Windows PC users, use putty to connect to the serial console through the "\\.\pipe\COM1" name pipe.
          Step 14   Shut down the VM using "vagrant halt -f".

          Vagrant Configuration Examples

          Mac Users

          # -*- mode: ruby -*-
          
          # vi: set ft=ruby :
          
           
          
          # All Vagrant configuration is done below. The "2" in Vagrant.configure
          
          # configures the configuration version (we support older styles for
          
          # backwards compatibility). Please don't change it unless you know what
          
          # you're doing.
          
          Vagrant.configure(2) do |config|
          
            # The most common configuration options are documented and commented below.
          
            # For a complete reference, please see the online documentation at
          
            # https:/​/​docs.vagrantup.com.
          
           
          
            # Every Vagrant development environment requires a box. You can search for
          
            # boxes at https:/​/​atlas.hashicorp.com/​search.
          
            # config.vm.base_mac = "0800276CEEAA"
          
            config.vm.define "n9kv1" do |n9kv1|
          
                  n9kv1.vm.box = "box-test"
          
                  n9kv1.ssh.insert_key = false
          
                  n9kv1.vm.boot_timeout = 180
          
                  n9kv1.vm.synced_folder '.', '/vagrant', disabled: true
          
                  n9kv1.vm.network "private_network", ip: "192.168.1.2", auto_config: false, virtualbox__intnet: "nxosv_network1"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network2"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network3"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network4"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network5"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network6"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network7"
          
                  n9kv1.vm.provider :virtualbox do |vb|
          
                          vb.customize ['modifyvm',:id,'--nicpromisc2','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc3','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc4','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc5','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc6','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc7','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc8','allow-all']
          
                          vb.customize "pre-boot", [
          
                                  "storageattach", :id,
          
          
          
                                  "--storagectl", "SATA",
          
                                  "--port", "1",
          
                                  "--device", "0",
          
                                  "--type", "dvddrive",
          
                                  "--medium", "./nxosv_config.iso",
          
                          ]
          
                  end
          
            end
          
          end
          
           

          Windows PC Users

          # -*- mode: ruby -*-
          
          # vi: set ft=ruby :
          
           
          
          # All Vagrant configuration is done below. The "2" in Vagrant.configure
          
          # configures the configuration version (we support older styles for
          
          # backwards compatibility). Please don't change it unless you know what
          
          # you're doing.
          
          Vagrant.configure(2) do |config|
          
            # The most common configuration options are documented and commented below.
          
            # For a complete reference, please see the online documentation at
          
            # https:/​/​docs.vagrantup.com.
          
           
          
            # Every Vagrant development environment requires a box. You can search for
          
            # boxes at https:/​/​atlas.hashicorp.com/​search.
          
            # config.vm.base_mac = "0800276CEEAA"
          
            config.vm.define "n9kv1" do |n9kv1|
          
                  n9kv1.vm.box = "box-test"
          
                  n9kv1.ssh.insert_key = false
          
                  n9kv1.vm.boot_timeout = 180
          
                  n9kv1.vm.synced_folder '.', '/vagrant', disabled: true
          
                  n9kv1.vm.network "private_network", ip: "192.168.1.2", auto_config: false, virtualbox__intnet: "nxosv_network1"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network2"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network3"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network4"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network5"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network6"
          
                  n9kv1.vm.network "private_network", auto_config: false, virtualbox__intnet: "nxosv_network7"
          
                  n9kv1.vm.provider :virtualbox do |vb|
          
                          vb.customize ['modifyvm',:id,'--uartmode1','server','\\\\.\pipe\COM1']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc2','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc3','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc4','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc5','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc6','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc7','allow-all']
          
                          vb.customize ['modifyvm',:id,'--nicpromisc8','allow-all']
          
                          vb.customize "pre-boot", [
          
                                  "storageattach", :id,
          
          
          
                                  "--storagectl", "SATA",
          
                                  "--port", "1",
          
                                  "--device", "0",
          
                                  "--type", "dvddrive",
          
                                  "--medium", "./nxosv_config.iso",
          
                          ]
          
                  end
          
            end
          
          end
          

          Deleting the VM


            Step 1   Shut down the VM.
            nxosv-user@fe-ucs-dt13:~/n9kv/box-test$ vagrant halt --force box-test ==> box-test:
            Forcing shutdown of VM... 
            nxosv-user@fe-ucs-dt13:~/n9kv/box-test$
            
            
            Step 2   Delete the VM from the system.
            nxosv-user@fe-ucs-dt13:~/n9kv/box-test$ vagrant destroy box-test
                box-test: Are you sure you want to destroy the 'box-test' VM? [y/N] y
            ==> box-test: Destroying VM and associated drives...
            nxosv-user@fe-ucs-dt13:~/n9kv/box-test$
            
            

            Network Topology Examples

            A key advantage of NX-OSv 9000 is that you can set up a quick networking topology without hardware or complicated cabling tasks to obtain a look and feel about a Cisco Nexus 9000 switch platform.

            For example, you can quickly set up a two node system with a server connecting to a NX-OSv 9000 virtual machine on laptop. A more complex system can also be setup with a large resource server to do a multiple node simulation. With the topology, you can do tooling and automation in a simulated network that could be applied in a real customer network environment. The following examples show how to interconnect VMs on a laptop or UCS servers.

            VirtualBox Topology on a Laptop





            An example diagram above is a typical configuration with NX-OSv 9000 and Ubuntu VM two node system. In this case, Both Ubuntu VM and NX-OSv 9000 would obtain IPs statically or dynamically visa DHCP protocol reachable from cloud. Similarly, both Ubuntu and NX-OSv 9000 can be managed through management network. Ubuntu VM can send/receive packets to NX-OSv 9000 through NX-OSv 9000 data ports, eth1/1, eth1/2, and eth1/3, or ... e1/9.

            Key to Setup:

            • Bridge or NAT to Laptop physical ethernet port for management connectivity

            • Internal Network for data ports between VMs, change "Promiscuous Mode" to "Allow All"









            Three Node Topology with Traffic Generator





            The nodes in the above diagram are instantiated using the hypervisor specific machine definitions. For networking, each data port interface pair needs to be connected to unique bridge/vSwitch. All the management ports of the NX-OSv 9000 (mgmt0) need to be connected to the management bridge and provided a unique IP address, which will enable access to these devices from an external network.

            Each data port interface pair that needs to be interconnected should be mapped to the same Bridge/vSwitch. Similar to VirtualBox topology, vSwitch/Bridge must have "Promiscuous Mode" set to "Accept" and "Vlan ID" to "All" for networking to work between NX-OSv 9000 nodes. Please read "Troubleshooting" section for hypervisor specific handling for data port communication.

            Five Nodes VXLAN Topology





            This topology can simulate basic vxlan functionality on NX-OSv 9000 platform. Similar bridge/vSwitch setup should be done as shown in other topology examples.