System Specifications

Environmental Specifications

Environment

Specification

Temperature

Ambient operating temperature

32 to 104°F (0 to 40°C)

Ambient nonoperating

–40 to 158°F (–40 to 70°C)

Relative humidity

Nonoperating

5 to 95%

Operating

5 to 90%

Altitude

Operating

0 to 13,123 feet (0 to 4,000 meters)

Switch Dimensions

Switch

Width

Depth

Height

Cisco Nexus 9336PQ

17.5 inches (44.5 cm)

22.5 inches (57.1 cm)

3.5 inches (8.9 cm) (2 RU)

Switch and Module Weights and Quantities

Component

Weight per Unit

Quantity

Cisco Nexus 9336PQ Chassis (N9K-C9336PQ)

24.3 lb (11.0 kg)

1

Fan Module

– Port-side exhaust (blue) (N9K-C9300-FAN3-B)

– Port-side intake (burgundy) (N9K-C9300-FAN3)

2.4 lb (1.1 kg)

2.4 lb (1.1 kg)

2

Power Supply module

– 1200-W AC port-side exhaust (blue) (N9K-PAC-1200W-B)

– 1200-W AC port-side intake (burgundy) (N9K-PAC-1200W)

– 1200-W HVAC/HVDC dual-direction (white) (N9K-PUV-1200W)

– 930-W DC port-side exhaust (gray) (UCS-PSU-6332-DC)

– 930-W DC port-side intake (green) (UCSC-PSU-930WDC)

2.64 lb (1.2 kg)

2.64 lb (1.2 kg)

2.42 lb (1.1 kg)

2.42 lb (1.1 kg)

2.42 lb (1.1 kg)

2 (1 for operations and 1 for redundancy)

Switch Power Input Requirements

This table lists the typical amount of power that the switch consumes. It also lists the maximum amount of power that you must provision for the switch and power supply for peak conditions.


Note


Some power supplies have capabilities that are greater than the maximum power requirements for a switch. To determine the power consumption characteristics for the switch, use the typical and maximum requirements that are listed here.


Switch Typical Power Consumption (AC or DC) Maximum Power Consumption (AC or DC) Heat Dissipation Requirement

Cisco Nexus 9336PQ

400 W

660 W

2252.013 BTUs per hour

Power Cable Specifications

These sections show the power cables that you can order and use with this switch.

3-kW AC Power Cable Specifications

Locale Power Cord Part Number Cord Set Rating Power Cord Illustration

Argentina

CAB-9K16A-ARG

16 A, 250 VAC

Brazil

CAB-9K16A-BRZ

16 A, 250 VAC

Korea

CAB-9K16A-KOR

16 A, 250 VAC

South Africa

CAB-9K16A-SA

16 A, 250 VAC

TBD

Australia and New Zealand

CAB-AC-16A-AUS

16 A, 250 VAC

Peoples Republic of China

CAB-AC-16A-CH

16 A, 250 VAC

Continental Europe

CAB-AC-2500W-EU

16 A, 250 VAC

India

CAB-C19-C20-IND

16 A, 250 VAC

India

PWR-CORD10-IND

16 A, 250 VAC

International

CAB-AC-2500W-INT

16 A, 250 VAC

Israel

CAB-AC-2500W-ISRL

16 A, 250 VAC

Japan and North America (nonlocking) 200-240 VAC operation

CAB-AC-2500W-US1

16 A, 250 VAC

Japan and North America (locking) 200-240 VAC operation

CAB-AC-C6K-TWLK

16 A, 250 VAC

Power distribution unit (PDU)

CAB-C19-CBN

16 A, 250 VAC

Switzerland

CAB-ACS-16

16 A, 250 VAC

Taiwan

CAB-AC-C19-TW

16 A, 250 VAC (IEC 60320 C19 to EL 218)

US

CAB-AC-STRT-C19US

16 A, 250 VAC (straight blade NEMA 6-20 plug)

All except Argentina, Brazil, and Japan

NO-PWR-CORD

No power cord is included with order.

N.A.

3-kW Universal AC/DC and 3-kW Dual Input Universal AC/DC Power Cable Specifications

Locale

Power Cord Part Number

Cord Set Rating

Power Cord Illustration

Australia and New Zealand

CAB-AC-16A-SG-AZ

16 A, 250 VAC (AU20LS3/Saf-D-Grid)

CAB-AC-16A-SG-EU

16A, 250 VAC

Israel

CAB-AC-16A-SG-IS

16 A, 250 VAC

International/UK

CAB-AC-16A-SG-IN

16 A, 250 VAC

Italy

CAB-AC-16A-SG-IT

16 A, 250 VAC

South Africa

CAB-AC-16A-SG-SA

16 A, 250 VAC

Switzerland

CAB-AC-16A-SG-SW

16 A, 250 VAC

North America

CAB-AC-20A-SG-C20

250 VAC 20 A

North America

CAB-AC-20A-SG-US

16 A, 250 VAC

North America (non locking) 200-240 VAC operation

CAB-AC-20A-SG-US2

250 VAC 20 A

North America

CAB-AC-20A-SG-US3

250 VAC 20 A

North America 277 VAC operation

CAB-AC-20A-SG-US4

277 VAC 20 A

International, Saf-D-Grid/Saf-D-Grid

CAB-HV-25A-SG-IN1

400 VAC 20 A

International, Ring Terminal source plug, Ring Terminal/Saf-D-Grid

CAB-HV-25A-SG-IN2

20A, 300 VAC/500 VDC

North America

CAB-HV-25A-SG-US1

277 VAC/ 240 VDC/ 380 VDC 25 A

North America

CAB-HV-25A-SG-US2

277 VAC/ 240 VDC/ 380 VDC 25 A

All except Argentina, Brazil, and Japan

NO-PWR-CORD

No power cord included with order

N.A.

3-kW DC Power Supply Power Cord Specifications

Each 3-kW DC power supply requires four customer-supplied power cables (two negative cables and two positive cables). We recommend using six gauge cables. Cisco supplies 6-gauge lugs for connections to the power supply. You supply the connectors that are required to connect the cables to the DC power source.