The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This appendix lists the Cisco XR 12410 router specifications.
The Cisco XR 12410 router specifications are presented in four tables:
•Table A-1, "Physical Specifications"
•Table A-2, "AC Electrical Specifications"
•Table A-3, "DC Electrical Specifications"
•Table A-4, "Environmental Specifications"
|
|
---|---|
Total AC Input Power |
3000 VA (volt-amps) per AC power supply |
Rated input voltage1 |
200-240 VAC nominal (range: 180 to 264 VAC) |
Rated input line frequency1 |
50/60 Hz nominal (range: 47 to 63 Hz) |
Input current rating1 |
15 A maximum @ 200 VAC |
Source AC service requirement1 |
20 A North America; 16 A international; 13 A UK |
Heat dissipation |
2800 W@9,544 BTU/hour |
Redundancy |
2 AC power supply modules required for 2N redundancy |
1 For each AC power supply module. |
|
|
---|---|
Total DC Input Power |
2800 W per DC power entry module |
Rated input voltage1 |
-48 VDC nominal in North America |
Input current rating1 |
40 A maximum (2x) |
Source DC service requirement1 |
Sufficient to supply the rated input current. Local codes apply. |
Redundancy |
2 DC power entry modules required for 2N redundancy |
1 For each DC power entry module. |
|
|
---|---|
Temperature |
Operating: 32° to 104°F (0° to 40°C) Nonoperating: -4° to 149°F (-20° to 65°C) |
Humidity |
Operating: 10 to 85% noncondensing Nonoperating: 5 to 95% noncondensing |
Altitude |
Operating: 0 to 10,000 ft (0 to 3,000 m) Nonoperating: 0 to 15,000 ft (0 to 4,570 m) |
Heat dissipation |
9,554 BTU/hr maximum |
Acoustic noise |
70 dBa maximum |
Shock |
Operating (halfsine): 21 in/sec (0.53 m/sec) Nonoperating (trapezoidal pulse): 20 G1 , 52 in/sec (1.32 m/sec) |
Vibration |
Operating: 0.35 Grms2 from 3 to 500 Hz Nonoperating: 1.0 Grms from3 to 500 Hz |