Technical Specifications


This appendix lists the Cisco XR 12410 router specifications.

Router Specifications

The Cisco XR 12410 router specifications are presented in four tables:

Table A-1, "Physical Specifications"

Table A-2, "AC Electrical Specifications"

Table A-3, "DC Electrical Specifications"

Table A-4, "Environmental Specifications"

Table A-1 Physical Specifications

Description
Value

Chassis height

37.5 in. (95.2 cm)

Chassis width

17.25 in. (43.8 cm)
19.0 in. (48.3 cm) including chassis rack-mount flanges and front door width

Chassis depth

22.0 in. (55.9 cm)
26.5 in (67.3 cm) including cable management system and front cover

Weight

chassis only

chassis: fully configured using all card slots and 2 AC input power supplies

125 lb (56.7 kg)

287 lb (130.2 kg)


Table A-2 AC Electrical Specifications

Description
Value

Total AC Input Power

3000 VA (volt-amps) per AC power supply
(2 AC power supplies per system)

Rated input voltage1

200-240 VAC nominal (range: 180 to 264 VAC)
220-240 VAC (UK)

Rated input line frequency1

50/60 Hz nominal (range: 47 to 63 Hz)
50/60 Hz UK

Input current rating1

15 A maximum @ 200 VAC
13 A maximum @220 to 240 VRMS (UK)

Source AC service requirement1

20 A North America; 16 A international; 13 A UK

Heat dissipation
(total maximum)

2800 W@9,544 BTU/hour

Redundancy

2 AC power supply modules required for 2N redundancy

1 For each AC power supply module.



Caution To ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.

Table A-3 DC Electrical Specifications

Description
Value

Total DC Input Power

2800 W per DC power entry module

Rated input voltage1

-48 VDC nominal in North America
-60 VDC nominal in the European Community
(range: -40.5 to -72 VDC (-75 VDC FOR 5mS))

Input current rating1

40 A maximum (2x)

Source DC service requirement1

Sufficient to supply the rated input current. Local codes apply.

Redundancy

2 DC power entry modules required for 2N redundancy

1 For each DC power entry module.



Caution To ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.

Table A-4 Environmental Specifications

Description
Value

Temperature

Operating: 32° to 104°F (0° to 40°C)

Nonoperating: -4° to 149°F (-20° to 65°C)

Humidity

Operating: 10 to 85% noncondensing

Nonoperating: 5 to 95% noncondensing

Altitude

Operating: 0 to 10,000 ft (0 to 3,000 m)

Nonoperating: 0 to 15,000 ft (0 to 4,570 m)

Heat dissipation

9,554 BTU/hr maximum

Acoustic noise

70 dBa maximum

Shock

Operating (halfsine): 21 in/sec (0.53 m/sec)

Nonoperating (trapezoidal pulse): 20 G1 , 52 in/sec (1.32 m/sec)

Vibration

Operating: 0.35 Grms2 from 3 to 500 Hz

Nonoperating: 1.0 Grms from3 to 500 Hz

1 G is a value of acceleration, where 1G equals 32.17 ft/sec2 (9.81 m/sec2).

2 Grms is the root mean square value of acceleration.