8-port 1GE (SFP) Fully subscribed
-
16-port 1GE (CSFP) Oversubscribed
-
18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
|
-
If the IM is in slot 0 in 8-port 1GE Fully subscribed mode or in 16-port/18-port 1GE Oversubscribed mode or 8-port 1GE + 1-port
1GE Fully subscribed mode, the IM in Slot 12 can only be in 8-port 1GE (SFP) Fully subscribed mode or in 16-port/18-port 1GE
(CSFP) Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode, 1-port 10GE Fully subscribed mode.
-
If Slot 0 is in 8-port 1G Fully subscribed mode or 16-port/18-port 1GE, or 16-port/18-port 1G Over subscribed or 1-port 10G
Fully subscribed mode or 8-port 1G + 1-port 1G Fully subscribed mode.
-
If Slot 0 is in 8-port 1G Fully subscribed mode or 16-port/18-port 1GE Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully
subscribed mode, then IMA8Z or IMA2F cannot be in slot 12.
-
IF IMA8CS1Z-M is in slot 0, then NCS4200 1T8S-10CS (10G_CEM) in slot 12 is not supported.
-
IF IMA8CS1Z-M is in slot 0 then NCS4200-1T8S-10CS (5G_CEM) in slot 12 is supported.
|
1
|
-
8-port 1GE (SFP) Fully subscribed
-
16-port 1GE (CSFP) Oversubscribed
-
18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
|
-
If Slot 1 is in 8-port 1G Fully subscribed or 16-port/18-port 1GE Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed
mode, the IMA8Z or IMA2F or IMA2Z cannot be in slot 11.
-
If the IM is in slot 1, then NCS4200-1T8S-10CS (10G_CEM) in slot 11 is not supported.
-
If the IM is in slot 1, then NCS4200-1T8S-10CS (5G_CEM) in slot 11 is supported.
|
2
|
-
8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed
-
16-port 1GE (CSFP) + 1-port 10GE (SFP+) Oversubscribed
-
16-port/18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10G Fully subscribed
-
8-port 1GE Fully subscribed
|
-
If Slot 2 is in 8-port 1G + 1-port 10G Fully subscribed mode, or 16-port 1G + 1-port 10G Over subscribed mode, then no IM
can be present in slot 12.
-
If Slot 2 is in 8-port 1G + 1-port 10G Fully subscribed mode, or 16-port 1G + 1-port 10G Over subscribed mode, then IMA8Z
or IMA2F cannot be in slot 4.
-
If the IM in slot 2, then NCS4200-1T8S-10CS (10G_CEM) in slot 12 is not supported.
-
If the IM is in slot 2, then NCS4200-1T8S-10CS (5G_CEM) in slot 12 is not supported.
-
If the IM is in slot 2 then NCS4200-48T1E1-CE in slot 12 is not supported.
-
If the IM is in slot 2 then NCS4200-48T3E3-CE in slot 12 is not supported.
|
3
|
All modes are supported.
|
-
If IMA8Z or IMA2F is in slot 3, then the IM is not supported on slots 5, 9, 13, and 15.
-
If Slot 3 has IMA8Z or IMA2F, then no IM can be present in slots 5, 9, 13, and 15.
|
4
|
All modes are supported.
|
-
If IMA8Z or IMA2F is in slot 4, then the IM is not supported in slots 2, 6, 10, and 14.
-
If Slot 4 has IMA8Z or IMA2F, then no IM can be present in slots 2, 6, 10, and 14.
|
5
|
-
8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed
-
16-port 1GE (CSFP) + 1-port 10GE (SFP+) Oversubscribed
-
16-port 1GE (CSFP) Oversubscribed
-
18-port 1GE (CSFP) Over subscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10GE Fully subscribed
-
8-port 1GE Fully subscribed
|
-
If the IM is in slot 5 in 8-port 1GE + 1-port 10GE Fully subscribed mode or in 16-port 1GE + 1-port 10GE Oversubscribed mode,
the the IM in slot 11 can only be in 8-port 1GE Fully subscribed mode or in 16-port/18-port 1GE (CSFP) Oversubscribed mode
or 8-port 1GE + 1-port 1GE Fully subscribed mode, or 1-port 10 GE Fully subscribed mode.
-
If Slot 5 is in 8-port 1G + 1-port 10G Fully subscribed, or 16-port 1G + 1-port 10G Over subscribed mode, then IMA8Z or IMA2F
cannot be in slot 3.
-
If the IM is in slot 5, then NCS4200-1T8S-10CS (10G_CEM) in slot 11 is not supported.
-
If the IM is in slot 5, then NCS4200-1T8S-10CS (5G_CEM) in slot 11 is supported.
|
6
|
-
8-port 1GE (SFP) Fully subscribed mode
-
16-port 1GE (CSFP) Oversubscribed
-
18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10 GE Fully subscribed
|
-
If Slot 6 is in 8-port 1GE fully subscribed, or 16-port 1GE Over subscribed, or 18-port 1GE Over subscribed or 8-port 1GE
+ 1-port 1GE fully subscribed or 1-port 10GE Fully subscribed mode, then IMA8Z or IMA2F cannot be in slot 4.
|
7
|
All modes are supported
|
—
|
8
|
All modes are supported
|
—
|
9
|
-
8-port 1GE (SFP) Fully subscribed
-
16-port/18-port 1GE (CSFP) Oversubscribed
-
16-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10 GE Fully subscribed
|
If Slot 9 is in 8-port 1GE fully subscribed, or 16-port 1GE Over subscribed mode, or 18-port 1GE Over subscribed mode or 8-port
1GE + 1-port 1GE fully subscribed or 1-port 10GE Fully subscribed mode, then IMA8Z or IMA2F cannot be in slot 3.
|
10
|
-
8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed
-
16-port 1GE (CSFP) + 1-port 10GE (SFP+) Oversubscribed
-
16-port/18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE+1-port 1GE Fully subscribed
-
1-port 10 GE Fully subscribed
-
8-port 1G Fully subscribed
|
-
If Slot 10 and 14 are in 8-port 1GE + 1-port 10GE Fully subscribed, or 16-port 1GE + 1-port 10GE Over subscribed mode, then
IMA8Z IMA2F cannot be in Slot 4.
-
If IM is in slot 10 then NCS4200-1T8S-10CS (10G_CEM) in slot 12 is not supported.
-
If IM is in slot 10, then NCS4200-1T8S-10CS (5G_CEM) in slot 12 is supported.
|
11
|
All modes are supported
|
-
IM can be in slot 11, only in 8-port 1GE (SFP) Fully subscribed mode, or in 16-port/18-port 1GE (CSFP) Oversubscribed mode
or 8-port 1GE + 1-port 1GE Fully subscribed mode, or 1-port 10 GE Fully subscribed mode if IPSEC is used (FLSASR907-IPSEC).
-
If the IM is slot 11, and in 8-port 1GE + 1 x 10GigE Fully subscribed mode, or in 16-port 1GE + 1-port 10GE Oversubscribed
mode, then the IM in Slots 5 and 15 can only be in 8-port 1GE (SFP) Fully subscribed mode, or in 16-port/18-port 1GE (CSFP)
Oversubscribed mode or 8-port 1GE +1-port 1GE Fully subscribed or 1-port 10GE Fully subscribed mode.
-
If the IM is in slot 11, and in 8-port 1GE Fully subscribed mode, or in 16-port 1GE Oversubscribed mode, or in 18-port 1GE
Oversubscribed mode or in 8-port 1GE + 1-port 1GE Fully subscribed or 1-port 10GE Fully subscribed, then the IM in Slot 15
can only be in 8-port 1GE (SFP) Fully subscribed mode, OR in 16-port/18-port 1GE (CSFP) Oversubscribed mode or 1-port 10GE
Fully subscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode.
-
IF IMA2Z is in slot 11, then the IM is in slot 15 only in 8-port 1GE (SFP) Fully subscribed mode, OR in 16-port/18-port 1GE
(CSFP) Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode or 1-port 10GE Fully subscribed mode, and no IM
can be present in slot 1.
-
If IMA8Z or IMA2Fis in slot 11, then the IM is in slots 5, 13 and 15 in 8-port 1GE Fully Subscribed, or in 16-port/18-port
1GE Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode or 1-port 10GE Fully subscribed mode, and no IM can
be present in slot 1.
-
If NCS4200-1T8S-10CS (10G_CEM) is in slot 11, then the IM in slots 5, 13 and 15 are in only 8-port 1GE Fully Subscribed, or
in 16/18-port 1GE Oversubscribed mode, and the IM in slot 1 not supported.
-
If NCS4200-1T8S-10CS (5G_CEM) is in slot 11, then the IM in slot 15 is in only 8-port 1GE Fully Subscribed, OR in 16/18-port
1GE Oversubscribed mode.
-
If NCS4200-48T1E1-CE is in slot 11, then the IM is in slot 15 is in only 8-port 1GE Fully Subscribed, or in 16/18-port 1GE
Oversubscribed mode.
-
If NCS4200-48T3E3-CE is in slot 11, then the IM is in slot 15 is in only 8-port 1GE Fully Subscribed, or in 16-port/18-port
1GE Oversubscribed mode.
|
12
|
All modes are supported
|
-
If the IM is in slot 12, and in 8-port 1GE + 1-port 10GE Fully subscribed mode, or in 16-port 1GE + 1-port 10GE Oversubscribed
mode, then no IM can be present in Slot 0, and the IM in Slot 2 can only be in 8-port 1GE (SFP) Fully subscribed mode, OR
in 16-port/18-port 1GE (CSFP) Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode or 1-port 10GE Fully subscribed
mode.
-
If the IM is in slot 12 and in 8-port 1GE Fully subscribed mode or in 16-port 1GE Oversubscribed mode, or in 18-port 1GE Oversubscribed
mode or 8-port 1GE + 1-port 1GE Fully subscribed mode or 1-port 10GE Fully subscribed mode, then the IM in Slot 2 can only
be in 8-port 1GE (SFP) Fully subscribed mode, OR in 16-port/18-port 1GE (CSFP) Oversubscribed mode or 8-port 1GE + 1-port
1GE Fully subscribed mode or 1-port 10GE Fully subscribed mode.
-
IF IMA2Z is in slot 12, then the IM is in slots 2 and 10 in 8-port 1GE (SFP) Fully subscribed mode, or in 16-port/18-port
1GE (CSFP) Oversubscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode or 1-port 10GE Fully subscribed mode.
-
If Slot 12 has IMA2Z, then slots 2 and 10 in 8-port 1GE Fully subscribed mode, or 16-port/18-port 1GE Over subscribed mode
or 1-port 10GE Fully subscribed mode or 8-port 1G + 1-port 1GE Fully subscribed mode.
-
If IMA8Z OR IMA2F is in slot 12, then the IM in slots 2, 10 and 14 in 8-port 1GE Fully Subscribed, or in 16-port/18-port 1GE
Oversubscribed mode and 1-port 10GE Fully subscribed mode or 8-port 1GE + 1-port 1GE Fully subscribed mode, and no IM can
be present from Slot 1 to Slot 0.
-
If NCS4200-1T8S-10CS (10G_CEM) is in slot 12, then the IM in slots 2, 10 and 14 are in only 8-port 1GE Fully Subscribed, OR
in 16-port/18-port 1GE Oversubscribed mode, and the IM in slot 0 not supported.
-
If NCS4200-1T8S-10CS (5G_CEM) is in slot 12, then the IM in slot 2 is in only 8-port 1GE Fully Subscribed, OR in 16-port/18-port
1GE Oversubscribed mode.
-
If NCS4200-48T1E1-CE is in slot 12, then the IM in slot 2 is in only 8-port 1GE Fully Subscribed, OR in 16-port/18-port 1GE
Oversubscribed mode.
-
If NCS4200-48T3E3-CE is in slot 12, then the IM in slot 2 is in only 8-port 1GE Fully Subscribed, or in 16-port/18-port 1GE
Oversubscribed mode.
|
13
|
-
8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed
-
16-port 1GE (CSFP) + 1-port 10GE (SFP+) Oversubscribed
-
16-port/18-port 1GE (CSFP Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10 GE Fully subscribed
-
8-port 1G Fully subscribed
|
-
If IPSEC is used (FLSASR907-IPSEC) then the IM can be in slot 13, only in 8-port 1GE (SFP) Fully subscribed mode, or in 16-port/18-port
1GE (CSFP) Oversubscribed mode. NCS4200-1T8S-10CS (10G_CEM) in slot 11 is not supported; but NCS4200-1T8S-10CS (5G_CEM) in slot 11 is supported.
-
If the IM in slot 13 is configured in 8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed mode, or in 16-port 1GE (CSFP)
+ 1-port 10GE (SFP+) Oversubscribed mode, or Fully Subscribed mode, then IPSEC cannot be configured.
If Slot 13 is in 8-port 1GE + 1-port 10GE Fully subscribed mode, or 16-port 1GE + 1-port 10GE Over subscribed mode, then IMA8Z
or IMA2F cannot be in slot 3.
-
If the IM is in slot 13, then NCS4200-1T8S-10CS (10G_CEM) in slot 11 is not supported.
-
If the IM is in slot 13, then NCS4200-1T8S-10CS (5G_CEM) in slot 11 is supported.
|
14
|
-
8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed
-
16-port 1GE (CSFP) + 1-port 10GE (SFP+) Oversubscribed
-
16-port/18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10 GE Fully subscribed
-
8-port 1GE Fully subscribed
|
-
IF 10G Y.1564/SADT is used, then the IM can be in slot 14 only in 8-port 1GE (SFP) Fully subscribed mode, or in 16-port/18-port
1GE (CSFP) Oversubscribed mode, or 8-port 1GE + 1-port 1GE Fully subscribed mode, or 1-port 10GE Fully subscribed mode. NCS4200-1T8S-10CS (10G_CEM) in slot 12 is not supported, but NCS4200-1T8S-10CS (5G_CEM) in slot 12 is supported.
-
If Slot 14 is in 8-port 1GE + 1-port 10GE Fully subscribed mode or 16-port 1GE + 1-port 10GE Over subscribed mode, then IMA8Z
or IMA2F cannot be in slot 4.
-
If the IM is in slot 14, then NCS4200-1T8S-10CS (10G_CEM) in slot 12 is not supported.
-
If the IM is in slot 14, then NCS4200-1T8S-10CS (5G_CEM) in slot 12 is supported.
|
15
|
-
8-port 1GE (SFP) + 1-port 10GE (SFP+) Fully subscribed
-
16-port 1GE (CSFP) + 1-port 10GE (SFP+) Oversubscribed
-
16-port/18-port 1GE (CSFP) Oversubscribed
-
8-port 1GE + 1-port 1GE Fully subscribed
-
1-port 10 GE Fully subscribed
-
8-port 1GE Fully subscribed
|
-
IF IMA8CS1Z-M is in slot 15 in 8-port 1GE + 1-port 10GE Fully subscribed mode, or in 16-port 1GE + 1-port 10GE Oversubscribed
mode, then the IM cannot be present in slot 11.
-
If Slot 15 is in 8-port 1GE + 1-port 10GE Fully subscribed mode, or 16-port 1GE + 1-port 10GE Over subscribed mode, then no
IM is supported on slot 11.
-
If Slot 15 is in 8-port 1GE + 1-port 10GE Fully subscribed, Or 16-port 1GE + 1-port 10GE Over subscribed mode, then IMA8Z
or IMA2F cannot be in slot 3.
-
If the IM is in slot 15, then NCS4200-1T8S-10CS (10G_CEM) in slot 11 is not supported.
-
If the IM is in slot 15, then NCS4200-1T8S-10CS (5G_CEM) in slot 11 is not supported.
-
If the IM is in slot 15, then NCS4200-48T1E1-CE in slot 11 is not supported.
-
If the IM is in slot 15, then NCS4200-48T3E3-CE in slot 11 is not supported.
|