Use the following commands to verify the alarm profile configuration:
-
show alarm profile—Displays the alarm profile configured for chassis.
-
show facility-alarm status—Displays the alarms status attached to a specific profile.
-
show controller/interface—shows the operational or attached alarm profile.
-
show logging—Displays the alarms reporting in syslog.
To display the alarm profile configured for chassis, use the show alarm profile command:
Router# show alarm profile
Alarm profile CHASSIS:
SONET/SDH:
Alarm Name Severity Syslog
Section Loss of Frame Failure CRITICAL Enabled
Line Alarm Indication Signal INFO Enabled
Line Remote Failure Indication INFO Enabled
Path Alarm Indication Signal INFO Enabled
Path Remote Failure Indication INFO Enabled
Path Loss of Pointer INFO Enabled
DS1:
Alarm Name Severity Syslog
Receiver has loss of signal CRITICAL Enabled
Receiver has loss of frame INFO Enabled
Receiver has remote alarm INFO Enabled
DS3:
Alarm Name Severity Syslog
Receiver has loss of signal MAJOR Enabled
DS1 Alarm Indication Signal MINOR Enabled
DS1 Loss Of Frame INFO Enabled
DS1 Remote Alarm Indication INFO Enabled
To display the alarm status attached to a specfic profile, use the show facility-alarm status command:
Router# show facility-alarm status | inc 0/4/1
SONET 0/4/1.OC48 Feb 01 2018 19:23:10 INFO Section Loss of Frame Failure [1]
To display the operational or attached alarm profile, use the show controllers command:
For show interface - alarm-profile
Router#sh interfaces gigabitEthernet 0/7/0
GigabitEthernet0/7/0 is down, line protocol is down
Alarm-profile: chassis_ains
Hardware is A900-IMA8CS1Z-M, address is 5006.ab62.3a36 (bia 5006.ab62.3a36)
MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full Duplex, 1000Mbps, link type is force-up, media type is SX
output flow-control is unsupported, input flow-control is on
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters never
Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 IP multicasts)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
Router# show interfaces GigabitEthernet 0/1/0
GigabitEthernet0/1/0 is up, line protocol is up
Sec-admin-state: in-service, Soak-time: NA,
soak-Time-left: NA, AINS-state: IS-NR
Hardware is A900-IMA8S1Z, address is f078.1685.3f12 (bia f078.1685.3f12)
MTU 1500 bytes, BW 1000000 Kbit/sec, DLY 10 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Keepalive set (10 sec)
Full Duplex, 1000Mbps, link type is auto, media type is SX
output flow-control is unsupported, input flow-control is on
ARP type: ARPA, ARP Timeout 04:00:00
Last input never, output never, output hang never
Last clearing of "show interface" counters 00:00:37
Input queue: 0/375/0/0 (size/max/drops/flushes); Total output drops: 0
Queueing strategy: fifo
Output queue: 0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
0 packets input, 0 bytes, 0 no buffer
Received 0 broadcasts (0 IP multicasts)
0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 packets output, 0 bytes, 0 underruns
0 output errors, 0 collisions, 0 interface resets
0 unknown protocol drops
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier, 0 pause output
0 output buffer failures, 0 output buffers swapped out
To display the alarm status configured for chassis, use the show facility-alarm status command:
Router# show facility-alarm status
System Totals Critical: 25 Major: 5 Minor: 0
Source Severity Syslog String Description [Index]
subslot 0/12 CRITICAL Active Card Removed OIR Alarm [0]
Power Supply Bay 3 CRITICAL PSU_MISSING Power Supply/FAN Module Missing [0]
module R1 MAJOR Unknown state [0]
SONET 0/4/1 CRITICAL SLOS Section Loss of Signal Failure [0]
SONET 0/4/1 CRITICAL SONET_LINK_DOWN Physical Port Link Down [59]
xcvr container 0/4/5 INFO XCVR_MISSING Transceiver Missing [0]
xcvr container 0/4/6 INFO XCVR_MISSING Transceiver Missing [0]
xcvr container 0/4/7 INFO XCVR_MISSING Transceiver Missing [0]
xcvr container 0/7/1 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/3 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/4 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/5 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/6 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/7 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/8 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/9 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/11 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/13 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/14 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/7/15 CRITICAL XCVR_MISSING_LINK_DOWN Transceiver Missing - Link Down [1]
xcvr container 0/8/18 INFO XCVR_MISSING Transceiver Missing [0]
xcvr container 0/8/19 INFO XCVR_MISSING Transceiver Missing [0]
xcvr container 0/14/2 INFO XCVR_MISSING Transceiver Missing [0]
xcvr container 0/14/4 INFO XCVR_MISSING Transceiver Missing [0]