F Show Commands

show fabric-binding database

show fabric-binding database [ { active [ vsan <i0> ] | vsan1 <i1> } ]

Syntax Description

show

Show running system information

fabric-binding

Show Fabric Binding

database

Show Fabric Binding Configured database

active

(Optional) Activated Fabric Bindings

vsan

(Optional) VSAN id

i0

(Optional) VSAN range

vsan1

(Optional) VSAN id

i1

(Optional) VSAN range

Command Mode

  • /exec

show fabric-binding efmd statistics

show fabric-binding efmd statistics [ vsan <i0> ]

Syntax Description

show

Show running system information

fabric-binding

Show Fabric Binding

efmd

Exchange Fabric Membership Data

statistics

EFMD protocol statistics

vsan

(Optional) VSAN id

i0

(Optional) VSAN range

Command Mode

  • /exec

show fabric-binding fip

show fabric-binding fip

Syntax Description

show

Show running system information

fabric-binding

Fabric Binding configuration

fip

Display the enabled FIP

Command Mode

  • /exec

show fabric-binding statistics

show fabric-binding statistics [ vsan <i0> ]

Syntax Description

show

Show running system information

fabric-binding

Show Fabric Binding

statistics

Statistics of Fabric Binding

vsan

(Optional) VSAN Id

i0

(Optional) VSAN range

Command Mode

  • /exec

show fabric-binding status

show fabric-binding status [ vsan <i0> ]

Syntax Description

show

Show running system information

fabric-binding

Show Fabric Binding

status

Fabric binding Status

vsan

(Optional) VSAN Id

i0

(Optional) VSAN range

Command Mode

  • /exec

show fabric-binding violations

show fabric-binding violations [ last <i0> ]

Syntax Description

show

Show running system information

fabric-binding

Show Fabric Binding

violations

Violations of Fabric Binding policies

last

(Optional) Latest n violations

i0

(Optional) Violation number

Command Mode

  • /exec

show fabric database dci

show fabric database dci [ { vrf { <vrf-name> | <vrf-known-name> } [ peer-id <peer-ip-address> ] [ detail ] } ] [ __readonly__ [ TABLE_database_dci <vrf_name> <state> <flags> <profile> <instance> ] [ TABLE_database_dci_detail <packet_arrival_time> <sent_to_database_manager_at> <received_parameters_from_database_manager_at> <sent_apply_to_configuration_manager_at> <completed_executing_all_commands_at> <sent_un_apply_to_configuration_manager_at> <completed_unapplying_all_commands_at> ] ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Fabric Database

dci

DCI Profile Database

vrf

(Optional) Display per-VRF information

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

peer-id

(Optional) management ip address of peer

peer-ip-address

(Optional) IP address in CIDR format

detail

(Optional) Show detailed information

__readonly__

(Optional) Read Only

TABLE_database_dci

(Optional) table show fabric database dci

vrf_name

(Optional)

state

(Optional)

flags

(Optional)

profile

(Optional)

instance

(Optional)

TABLE_database_dci_detail

(Optional) detail for table show fabric database dci

packet_arrival_time

(Optional) Profile request time

sent_to_database_manager_at

(Optional) Profile request sent to DCNM

received_parameters_from_database_manager_at

(Optional) Profile downloaded from DCNM

sent_apply_to_configuration_manager_at

(Optional) Profile sent to PPM to apply

completed_executing_all_commands_at

(Optional) Profile applied by PPM

sent_un_apply_to_configuration_manager_at

(Optional) Profile un-apply sent to PPM

completed_unapplying_all_commands_at

(Optional) Profile un-applied by PPM

Command Mode

  • /exec

show fabric database host

show fabric database host [ detail ] [ { vni <vni-id> } | { dot1q <vlan-id> } ] [ __readonly__ [ TABLE_database_host [ <trigger_source> ] [ <client_type> ] [ <got_trigger_at> ] [ <number_of_client_hosts> ] [ <number_of_associated_interfaces> ] [ <profile_be_un_applied_in_seconds> ] [ <new_vdp_requests_be_accepted_in_seconds> ] [ <recovered_profile_be_checked_for_validity_in_seconds> ] [ <mac_aging_checked_in_seconds> ] [ <sent_to_database_manager_at> ] [ <received_parameters_from_database_manager_at> ] [ <displaying_parameters_for_profile> ] [ <displaying_parameters_for_instance> ] [ <no_parameters_for_the_profile> ] [ <displaying_re_written_parameters_for_vpc_role> ] [ TABLE_parameter [ <parameter_index> ] [ <parameter> ] ] [ TABLE_static_profile <profile> <instance> <no_parameters_for_the_profile> ] [ TABLE_migrated_profile <profile> <instance_index> <previous_profile> <previous_instance_index> ] [ TABLE_rollback_profile <profile> <instance_index> ] [ <got_vlan_allocated_from_vlan_manager_at> ] [ <sent_apply_to_configuration_manager_at> ] [ <completed_executing_all_commands_at> ] [ <sent_to_vpc_peer_at> ] [ <completed_executing_all_commands_on_vpc_peer_at> ] [ <sent_un_apply_to_configuration_manager_at> ] [ <completed_unapplying_all_commands_at> ] ] [ TABLE_database_host_vni { [ <vni_id> ] [ <vlan_id> ] [ <state> <flag> <profile_name> <instance_name> ] [ <packet_arrival_time> <request_profile_time> <got_profile_time> <sent_to_PPM_time> <profile_apply_time> <del_to_PPM_time> ] [ { TABLE_database_host_detail <interface> <encap> <flags> <state> [ <vsi_id> ] [ <client> ] [ <host> ] } ] } ] [ TABLE_database_host_vlan { [ <vlan_id> ] [ <vni_id> ] [ <state> <flag> <profile_name> <instance_name> ] [ <packet_arrival_time> <request_profile_time> <got_profile_time> <sent_to_PPM_time> <profile_apply_time> <del_to_PPM_time> ] [ { TABLE_database_host_detail <interface> <encap> <flags> <state> [ <vsi_id> ] } ] } ] [ TABLE_extranet_vrf_entries { <vrf> <l3_vni> <state> <profile> <instance> } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Fabric Database

host

Host to profile mapping

detail

(Optional) Show hosts and interfaces

vni

(Optional) Virtual Network Identifier

vni-id

(Optional)

dot1q

(Optional) Dot1Q Encapsulation

vlan-id

(Optional)

__readonly__

(Optional) Read Only

TABLE_database_host

(Optional) table show fabric database host {dot1q | vni}

trigger_source

(Optional) TODO

client_type

(Optional) TODO

got_trigger_at

(Optional) TODO

number_of_client_hosts

(Optional) TODO

number_of_associated_interfaces

(Optional) TODO

profile_be_un_applied_in_seconds

(Optional) TODO

new_vdp_requests_be_accepted_in_seconds

(Optional) TODO

recovered_profile_be_checked_for_validity_in_seconds

(Optional) TODO

mac_aging_checked_in_seconds

(Optional) TODO

sent_to_database_manager_at

(Optional) TODO

received_parameters_from_database_manager_at

(Optional) TODO

displaying_parameters_for_profile

(Optional) TODO

displaying_parameters_for_instance

(Optional) TODO

no_parameters_for_the_profile

(Optional) TODO

displaying_re_written_parameters_for_vpc_role

(Optional) TODO

TABLE_parameter

(Optional) table show the parameters

parameter_index

(Optional) TODO

parameter

(Optional) TODO

TABLE_static_profile

(Optional) show static profile

profile

(Optional) TODO

instance

(Optional) TODO

no_parameters_for_the_profile

(Optional) TODO

TABLE_migrated_profile

(Optional) show migrated profile

profile

(Optional) TODO

instance_index

(Optional) TODO

previous_profile

(Optional) TODO

previous_instance_index

(Optional) TODO

TABLE_rollback_profile

(Optional) show rollback profile

profile

(Optional) TODO

instance_index

(Optional) TODO

got_vlan_allocated_from_vlan_manager_at

(Optional) TODO

sent_apply_to_configuration_manager_at

(Optional) TODO

completed_executing_all_commands_at

(Optional) TODO

sent_to_vpc_peer_at

(Optional) TODO

completed_executing_all_commands_on_vpc_peer_at

(Optional) TODO

sent_un_apply_to_configuration_manager_at

(Optional) TODO

completed_unapplying_all_commands_at

(Optional) TODO

TABLE_database_host_vni

(Optional) table show fabric database host vni based

vni_id

(Optional) TODO Add comment

vlan_id

(Optional) TODO Add comment

state

(Optional) TODO Add comment

flag

(Optional) TODO

profile_name

(Optional) TODO

instance_name

(Optional) TODO

packet_arrival_time

(Optional) TODO

request_profile_time

(Optional) TODO

got_profile_time

(Optional) TODO

sent_to_PPM_time

(Optional) TODO

profile_apply_time

(Optional) TODO

del_to_PPM_time

(Optional) TODO

TABLE_database_host_detail

(Optional) table show fabric database host detail

interface

(Optional) TODO

encap

(Optional) TODO

flags

(Optional) TODO

state

(Optional) TODO

vsi_id

(Optional) TODO

client

(Optional) TODO

host

(Optional) TODO

TABLE_database_host_vlan

(Optional) table show fabric database host vlan based

vlan_id

(Optional) TODO Add comment

vni_id

(Optional) TODO Add comment

state

(Optional) TODO Add comment

flag

(Optional) TODO

profile_name

(Optional) TODO

instance_name

(Optional) TODO

packet_arrival_time

(Optional) TODO

request_profile_time

(Optional) TODO

got_profile_time

(Optional) TODO

sent_to_PPM_time

(Optional) TODO

profile_apply_time

(Optional) TODO

del_to_PPM_time

(Optional) TODO

TABLE_database_host_detail

(Optional) table show fabric database host detail

interface

(Optional) TODO

encap

(Optional) TODO

flags

(Optional) TODO

state

(Optional) TODO

vsi_id

(Optional) TODO

TABLE_extranet_vrf_entries

(Optional) table extranet VRF entries

vrf

(Optional) TODO

l3_vni

(Optional) TODO

state

(Optional) TODO

profile

(Optional) TODO

instance

(Optional) TODO

Command Mode

  • /exec

show fabric database host statistics

show fabric database host statistics [ __readonly__ [ TABLE_database_host_statistics { [ <data_snoop_triggers> ] [ <data_snoop_deletes> ] [ <data_snoop_responses> ] [ <vdp_association_requests> ] [ <vdp_deassociation_requests> ] [ <vdp_association_responses> ] [ <vdp_error_responses> ] [ <unsupported_interfaces> ] [ <no_profile_map_errors> ] [ <outstanding_delete_retry_add> ] [ <duplicate_add_existing_host> ] [ <hmm_api_error_cannot_add_host> ] [ <existing_profile_new_host> ] [ <profile_apply_from_vpc_peer> ] [ <profile_un_apply_from_vpc_peer> ] [ <host_apply_from_vpc_peer> ] [ <host_un_apply_from_vpc_peer> ] [ <early_delete_cancel_add> ] [ <dhcp_requests> ] [ <dhcp_responses> ] [ <dhcp_error_responses> ] [ <adbm_requests> ] [ <adbm_responses> ] [ <adbm_error_responses> ] [ <adbm_error_requests> ] [ <adbm_db_notifications> ] [ <vnseg_no_bridge_domain> ] [ <vnseg_encap_responses> ] [ <vnseg_vni_responses> ] [ <vnseg_unknown_responses> ] [ <vnseg_bd_down_notif> ] [ <bd_mgr_requests> ] [ <bd_mgr_success_responses> ] [ <bd_mgr_failure_responses> ] [ <bd_mgr_unreserve> ] [ <bd_mgr_inconsistencies> ] [ <no_mac_on_bd_notif> ] [ <refresh_failures> ] [ <profile_apply_received> ] [ <profile_vpc_queued> ] [ <profile_local_apply_queued> ] [ <profile_local_unapply_queued> ] [ <profile_apply_sent> ] [ <profile_apply_responses> ] [ <profile_apply_success> ] [ <profile_unapply_success> ] [ <profile_apply_failure> ] [ <profile_commands> ] [ <profile_error_incomplete_configs> ] [ <profile_api_error> ] [ <profile_unapply_sent> ] [ <profile_top_queue_adds> ] [ <profile_high_queue_adds> ] [ <profile_low_queue_adds> ] [ <profile_unapply_failure> ] [ <outstanding_vlan_requests> ] [ <outstanding_adbm_requests> ] [ <outstanding_profile_applies> ] [ <outstanding_vpc_profile_applies> ] [ <node_recon_pending> ] [ <node_recon_attempts> ] [ <node_recon_failures> ] } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Fabric Database

host

Auto-configured Hosts

statistics

Statistics - Mostly shows non-zero values

__readonly__

(Optional) Read Only

TABLE_database_host_statistics

(Optional) table show fabric database host statistics

data_snoop_triggers

(Optional) TODO

data_snoop_deletes

(Optional) TODO

data_snoop_responses

(Optional) TODO

vdp_association_requests

(Optional) TODO

vdp_deassociation_requests

(Optional) TODO

vdp_association_responses

(Optional) TODO

vdp_error_responses

(Optional) TODO

unsupported_interfaces

(Optional) TODO

no_profile_map_errors

(Optional) TODO

outstanding_delete_retry_add

(Optional) TODO

duplicate_add_existing_host

(Optional) TODO

hmm_api_error_cannot_add_host

(Optional) TODO

existing_profile_new_host

(Optional) TODO

profile_apply_from_vpc_peer

(Optional) TODO

profile_un_apply_from_vpc_peer

(Optional) TODO

host_apply_from_vpc_peer

(Optional) TODO

host_un_apply_from_vpc_peer

(Optional) TODO

early_delete_cancel_add

(Optional) TODO

dhcp_requests

(Optional) TODO

dhcp_responses

(Optional) TODO

dhcp_error_responses

(Optional) TODO

adbm_requests

(Optional) TODO

adbm_responses

(Optional) TODO

adbm_error_responses

(Optional) TODO

adbm_error_requests

(Optional) TODO

adbm_db_notifications

(Optional) TODO

vnseg_no_bridge_domain

(Optional) TODO

vnseg_encap_responses

(Optional) TODO

vnseg_vni_responses

(Optional) TODO

vnseg_unknown_responses

(Optional) TODO

vnseg_bd_down_notif

(Optional) TODO

bd_mgr_requests

(Optional) TODO

bd_mgr_success_responses

(Optional) TODO

bd_mgr_failure_responses

(Optional) TODO

bd_mgr_unreserve

(Optional) TODO

bd_mgr_inconsistencies

(Optional) TODO

no_mac_on_bd_notif

(Optional) TODO

refresh_failures

(Optional) TODO

profile_apply_received

(Optional) TODO

profile_vpc_queued

(Optional) TODO

profile_local_apply_queued

(Optional) TODO

profile_local_unapply_queued

(Optional) TODO

profile_apply_sent

(Optional) TODO

profile_apply_responses

(Optional) TODO

profile_apply_success

(Optional) TODO

profile_unapply_success

(Optional) TODO

profile_apply_failure

(Optional) TODO

profile_commands

(Optional) TODO

profile_error_incomplete_configs

(Optional) TODO

profile_api_error

(Optional) TODO

profile_unapply_sent

(Optional) TODO

profile_top_queue_adds

(Optional) TODO

profile_high_queue_adds

(Optional) TODO

profile_low_queue_adds

(Optional) TODO

profile_unapply_failure

(Optional) TODO

outstanding_vlan_requests

(Optional) TODO

outstanding_adbm_requests

(Optional) TODO

outstanding_profile_applies

(Optional) TODO

outstanding_vpc_profile_applies

(Optional) TODO

node_recon_pending

(Optional) TODO

node_recon_attempts

(Optional) TODO

node_recon_failures

(Optional) TODO

Command Mode

  • /exec

show fabric database host summary

show fabric database host summary [ __readonly__ [ TABLE_database_host_summary { <number_of_instances_applied> <number_of_client_hosts> <recovery_timeout_minute> <cleanup_timeout_minute> <client_add_suppression_timeout_minute> <mac_aging_timeout_minute> <autoid_support> } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Fabric Database

host

Auto-configured Hosts

summary

Summary

__readonly__

(Optional) Read Only

TABLE_database_host_summary

(Optional) table show fabric database host summary

number_of_instances_applied

(Optional) TODO

number_of_client_hosts

(Optional) TODO

recovery_timeout_minute

(Optional) TODO

cleanup_timeout_minute

(Optional) TODO

client_add_suppression_timeout_minute

(Optional) TODO

mac_aging_timeout_minute

(Optional) TODO

autoid_support

(Optional) List of supported auto-generate ids

Command Mode

  • /exec

show fabric database profile-map

show fabric database profile-map { global | [ <id> | interface <interface-id> ] } [ __readonly__ [ TABLE_database_profile_map { <map> <proto> <vni> <dot1q> <flags> <profile_name> } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Fabric Database

profile-map

Profile Map

global

Global profile (apply to all interfaces)

id

(Optional) Profile Map ID

interface

(Optional) Specified interface to display

interface-id

(Optional) Name of interface

__readonly__

(Optional) Read Only

TABLE_database_profile_map

(Optional) table show fabric database profile-map

map

(Optional) TODO

proto

(Optional) TODO

vni

(Optional) TODO

dot1q

(Optional) TODO

flags

(Optional) TODO

profile_name

(Optional) TODO

Command Mode

  • /exec

show fabric database static-host

show fabric database static-host [ __readonly__ { TABLE_database_static_host <host_key> <interface> <state> <retry_delay> <retry_attempts> } ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Fabric Database

static-host

Configured Static Hosts

__readonly__

(Optional) Read Only

TABLE_database_static_host

(Optional) table show fabric database static-host

host_key

(Optional) static-host key

interface

(Optional) interface name

state

(Optional) static-host state

retry_delay

(Optional) seconds until next retry

retry_attempts

(Optional) cumulative retry attempts

Command Mode

  • /exec

show fabric database statistics

show fabric database statistics [ type { network | profile | cabling | partition | bl-dci | host } ] [ __readonly__ { TABLE_types <dbtype> <requests> <dispatched> <not_dispatched> <re_dispatched> } [ { TABLE_dbs <is_active> <type> <prot> <serverdb> [ <reqs> <ok> <nores> <err> <tmout> <pend> ] } ] { LastPollTime <poll_time> } { LastUpdateTime <update_time> } [ { TABLE_updates <update_type> <update_status> } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

database

Show Fabric Database

statistics

Show database statistics

type

(Optional) Enter database type

network

(Optional) Network Database

profile

(Optional) Port or Switch Profile Database

cabling

(Optional) Cable Management Database

partition

(Optional) Partition Database

bl-dci

(Optional) Border Leaf - DCI

host

(Optional) Host

__readonly__

(Optional)

TABLE_types

(Optional) totals by type

dbtype

(Optional) type of database

requests

(Optional) number of requests

dispatched

(Optional) number dispatched

not_dispatched

(Optional) number not dispatched

re_dispatched

(Optional) number re-dispatched

TABLE_dbs

(Optional) per-database stats

is_active

(Optional) active/inactive

type

(Optional) database type

prot

(Optional) database protocol

serverdb

(Optional) server database

reqs

(Optional) requests

ok

(Optional) OK

nores

(Optional) nores

err

(Optional) err

tmout

(Optional) tmout

pend

(Optional) pend

LastPollTime

(Optional) last poll time

poll_time

(Optional) poll time

LastUpdateTime

(Optional) last update time for db status change

update_time

(Optional) update time

TABLE_updates

(Optional) totals ty type

update_type

(Optional) db type

update_status

(Optional) db status

Command Mode

  • /exec

show fabric forwarding host-db

show fabric forwarding host-db [ { vrf { <vrf-name> | <vrf-known-name> | all } } ] [ __readonly__ [ TABLE_forwarding_host_db_vrf { <vrf> <vrf_id> <vrf_state> <vrf_reason> <vni_id> <refcount> <conversational_learning> [ TABLE_limit_type <limit_type> <enable> <threshold> <action> ] [ TABLE_ipv4 <address_family> <vrf> <table_id> <table_state> <refcount> <local_hosts> <remote_hosts> <aggregates> [ TABLE_aggregate_list <aggregate_subnet_prefix_list> <aggregate_subnet_prefix_state> ] ] [ TABLE_ipv6 <address_family> <vrf> <table_id> <table_state> <refcount> <local_hosts> <remote_hosts> <aggregates> [ TABLE_aggregate_list <aggregate_subnet_prefix_list> <aggregate_subnet_prefix_state> ] ] } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

forwarding

Fabric Forwarding Protocol: Host Mobility Manager (HMM)

host-db

Host Database info

vrf

(Optional) Display per-VRF information

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display information for all VRFs

__readonly__

(Optional) Read Only

TABLE_forwarding_host_db_vrf

(Optional) table show fabric forwarding host-db vrf

vrf

(Optional) TODO

vrf_id

(Optional) TODO

vrf_state

(Optional) TODO

vrf_reason

(Optional) TODO

vni_id

(Optional) TODO

refcount

(Optional) TODO

conversational_learning

(Optional) TODO

TABLE_limit_type

(Optional) table for limit type

limit_type

(Optional) TODO

enable

(Optional) TODO

threshold

(Optional) TODO

action

(Optional) TODO

TABLE_ipv4

(Optional) Information for address family IPv4

address_family

(Optional) TODO

vrf

(Optional) TODO

table_id

(Optional) TODO

table_state

(Optional) TODO

refcount

(Optional) TODO

local_hosts

(Optional) TODO

remote_hosts

(Optional) TODO

aggregates

(Optional) TODO

TABLE_aggregate_list

(Optional) table for aggregate subnet prefix list

aggregate_subnet_prefix_list

(Optional) TODO

TABLE_ipv6

(Optional) Information for address family IPv6

address_family

(Optional) TODO

vrf

(Optional) TODO

table_id

(Optional) TODO

table_state

(Optional) TODO

refcount

(Optional) TODO

local_hosts

(Optional) TODO

remote_hosts

(Optional) TODO

aggregates

(Optional) TODO

TABLE_aggregate_list

(Optional) table for aggregate subnet prefix list

aggregate_subnet_prefix_list

(Optional) TODO

aggregate_subnet_prefix_state

(Optional) TODO

Command Mode

  • /exec

show fabric forwarding ip local

show fabric forwarding ip { local-host-db [ { vrf { <vrf-name> | <vrf-known-name> | all } } ] [ <ip-prefix> ] } [ __readonly__ [ TABLE_forwarding_ip_local_host_db_vrf { <hmm_host> <vrf> <status_in> { TABLE_hosts <host> <mac_address> <svi> <flags_0x> <physical_interface> <status> } } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

forwarding

Fabric Forwarding Protocol: Host Mobility Manager (HMM)

ip

Display IP information

local-host-db

HMM Local Host Database

vrf

(Optional) Display per-VRF information

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display information for all VRFs

ip-prefix

(Optional) IP prefix in CIDR format

__readonly__

(Optional) Read Only

TABLE_forwarding_ip_local_host_db_vrf

(Optional) table show fabric forwarding ip local-host-db vrf

hmm_host

(Optional) TODO

vrf

(Optional) TODO

status_in

(Optional) TODO

TABLE_hosts

(Optional) table show information for each hosts

host

(Optional) TODO

mac_address

(Optional) TODO

svi

(Optional) TODO

flags_0x

(Optional) TODO

physical_interface

(Optional) TODO

status

(Optional) *-valid, x-deleted, a-aged out, c-cleaned

Command Mode

  • /exec

show fabric forwarding ipv6 local

show fabric forwarding ipv6 { local-host-db [ { vrf { <vrf-name> | <vrf-known-name> | all } } ] [ <ipv6-prefix> ] } [ __readonly__ [ TABLE_forwarding_ipv6_local_host_db_vrf { <hmm_host> <vrf> <status_in> { TABLE_hosts <host> <mac_address> <svi> <flags_0x> <physical_interface> <status> } } ] ]

Syntax Description

show

Show running system information

fabric

Fabric

forwarding

Fabric Forwarding Protocol: Host Mobility Manager (HMM)

ipv6

Display IPv6 information

local-host-db

HMM Local Host Database

vrf

(Optional) Display per-VRF information

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display information for all VRFs

__readonly__

(Optional) Read Only

TABLE_forwarding_ipv6_local_host_db_vrf

(Optional) table show fabric forwarding ipv6 local-host-db vrf

hmm_host

(Optional) TODO

vrf

(Optional) TODO

status_in

(Optional) TODO

TABLE_hosts

(Optional) table show information for each hosts

host

(Optional) TODO

mac_address

(Optional) TODO

svi

(Optional) TODO

flags_0x

(Optional) TODO

physical_interface

(Optional) TODO

status

(Optional) *-valid, x-deleted, a-aged out, c-cleaned

Command Mode

  • /exec

show fabric multicast globals

show fabric multicast globals [ __readonly__ [ <pruning> ] [ <switch_role> ] [ <fabric_control_seg> ] [ <peer_fabric_ctrl_addr> ] [ <advertise_vpc_rpf_routes> ] [ <created_vni_list> ] [ <fwd_encap> ] [ <mrib_sync_delay> ] [ <bgp_eor_rcvd> ] [ <bgp_eor_rcvd_ts> ] [ <cli_done_rcvd> ] [ <cli_done_rcvd_ts> ] [ <local_nlri_req> ] [ <dist_dr> ] [ <dist_pending> ] [ <spt_only> ] [ <pim_trm_bl> ] [ <pim6_trm_bl> ] [ <l2_trm_evpn> ] ]

Syntax Description

show

Show running system information

fabric

Fabric

multicast

Multicast information

globals

show the global settings

__readonly__

(Optional)

pruning

(Optional)

switch_role

(Optional)

fabric_control_seg

(Optional)

peer_fabric_ctrl_addr

(Optional)

advertise_vpc_rpf_routes

(Optional)

created_vni_list

(Optional)

fwd_encap

(Optional)

mrib_sync_delay

(Optional)

bgp_eor_rcvd

(Optional)

bgp_eor_rcvd_ts

(Optional)

cli_done_rcvd

(Optional)

cli_done_rcvd_ts

(Optional)

local_nlri_req

(Optional)

dist_dr

(Optional)

dist_pending

(Optional)

spt_only

(Optional)

pim_trm_bl

(Optional)

pim6_trm_bl

(Optional)

l2_trm_evpn

(Optional)

Command Mode

  • /exec

show fabric multicast ipv4 l2 vni

show fabric multicast { ipv4 | ipv6 } { l2-mroute } vni { <vni-id> | all } [ __readonly__ TABLE_vni <vnid> [ TABLE_mroute <mroute_desc> [ TABLE_fabric <fabric_node_addr> ] ] ]

Syntax Description

show

Show running system information

fabric

Fabric

multicast

Multicast information

ipv4

Display IP information

ipv6

Display IPv6 information

l2-mroute

display l2-mroute status

vni

Virtual Network Identifier

vni-id

VNI number

all

Display all L2 VNI NGMVPN is aware of

__readonly__

(Optional)

TABLE_vni

(Optional)

vnid

(Optional)

TABLE_mroute

(Optional)

mroute_desc

(Optional)

TABLE_fabric

(Optional)

fabric_node_addr

(Optional)

Command Mode

  • /exec

show fabric multicast statistics

show fabric multicast statistics [ __readonly__ [ <remote_nlri_msgs_rx> ] [ <remote_nlri_msgs_rx_fail> ] [ <local_nlri_msgs_tx> ] [ <local_nlri_msgs_tx_fail> ] [ <import_rt_msgs_tx> ] [ <import_rt_msgs_tx_fail> ] [ <m2rib_msgs_tx> ] [ <m2rib_msgs_tx_fail> ] [ <mrib_msgs_tx> ] [ <mrib_msgs_tx_fail> ] [ <m6rib_msgs_tx> ] [ <m6rib_msgs_tx_fail> ] [ <pim_msgs_tx> ] [ <pim_msgs_tx_fail> ] [ <pim_msgs_rx> ] [ <pim_all_remote_ssm_rp_req_rx> ] [ <pim6_msgs_tx> ] [ <pim6_msgs_tx_fail> ] [ <pim6_msgs_rx> ] [ <pim6_all_remote_ssm_rp_req_rx> ] [ <remote_nlri_ack_tx> ] [ <remote_nlri_ack_tx_fail> ] [ <all_local_nlri_req_rx> ] [ <local_nlri_ack_rx> ] [ <remote_route_req_tx> ] [ <remote_route_req_tx_fail> ] [ <pim6_all_local_ssm_rp_req_tx> ] [ <pim6_all_local_ssm_rp_req_tx_fail> ] [ <igmp_local_route_rx> ] [ <igmp_local_route_ack_rx> ] [ <igmp_msgs_tx> ] [ <igmp_msgs_tx_fail> ] [ <igmp_l2_vni_up_down_rx> ] [ <mts_q_high_warning_rx> ] [ <mts_q_full_warning_rx> ] ]

Syntax Description

show

Show running system information

fabric

Fabric

multicast

Multicast information

statistics

Show statistics

__readonly__

(Optional)

remote_nlri_msgs_rx

(Optional)

remote_nlri_msgs_rx_fail

(Optional)

local_nlri_msgs_tx

(Optional)

local_nlri_msgs_tx_fail

(Optional)

import_rt_msgs_tx

(Optional)

import_rt_msgs_tx_fail

(Optional)

m2rib_msgs_tx

(Optional)

m2rib_msgs_tx_fail

(Optional)

mrib_msgs_tx

(Optional)

mrib_msgs_tx_fail

(Optional)

m6rib_msgs_tx

(Optional)

m6rib_msgs_tx_fail

(Optional)

pim_msgs_tx

(Optional)

pim_msgs_tx_fail

(Optional)

pim_msgs_rx

(Optional)

pim_all_remote_ssm_rp_req_rx

(Optional)

pim6_msgs_tx

(Optional)

pim6_msgs_tx_fail

(Optional)

pim6_msgs_rx

(Optional)

pim6_all_remote_ssm_rp_req_rx

(Optional)

remote_nlri_ack_tx

(Optional)

remote_nlri_ack_tx_fail

(Optional)

all_local_nlri_req_rx

(Optional)

local_nlri_ack_rx

(Optional)

remote_route_req_tx

(Optional)

remote_route_req_tx_fail

(Optional)

pim6_all_local_ssm_rp_req_tx

(Optional)

pim6_all_local_ssm_rp_req_tx_fail

(Optional)

igmp_local_route_rx

(Optional)

igmp_local_route_ack_rx

(Optional)

igmp_msgs_tx

(Optional)

igmp_msgs_tx_fail

(Optional)

igmp_l2_vni_up_down_rx

(Optional)

mts_q_high_warning_rx

(Optional)

mts_q_full_warning_rx

(Optional)

Command Mode

  • /exec

show fabric multicast vrf

show fabric multicast vrf [ { <vrf-name> | <vrf-known-name> | all } ] [ __readonly__ TABLE_vrf <context_name> [ <context_id> ] [ <vprime_iod> ] [ <vnid> ] [ <l3trm> ] [ <iropt> ] ]

Syntax Description

show

Show running system information

fabric

Fabric

multicast

Multicast information

vrf

Display per-VRF information

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display all VRFs NGMVPN is aware of

__readonly__

(Optional)

TABLE_vrf

(Optional)

context_name

(Optional)

context_id

(Optional)

vprime_iod

(Optional)

vnid

(Optional)

l3trm

(Optional)

iropt

(Optional)

Command Mode

  • /exec

show fabric switch information

show fabric switch information [ vsan <i0> ]

Syntax Description

show

Show running system information

fabric

Show Fabric Information

switch

Show switch details.

information

Show switch model, version and other details

vsan

(Optional) VSAN id

i0

(Optional) VSAN range

Command Mode

  • /exec

show fc2 bind

show fc2 bind [ __readonly__ { TABLE_fc2bind <SOCKET> <FLAGS> <NLEVEL> <RULE> <SINDEX> <VSAN> <D_ID> <MASK> <TYPE> <SUBTYPE> <M_VALUES> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

bind

show fc2 socket bindings

__readonly__

(Optional) Read only

TABLE_fc2bind

(Optional) show fc2 bind

SOCKET

(Optional) socket

FLAGS

(Optional) flags

NLEVEL

(Optional) nlevel

RULE

(Optional) rule

SINDEX

(Optional) sidnex

VSAN

(Optional) vsan

D_ID

(Optional) d_id

MASK

(Optional) mask

TYPE

(Optional) type

SUBTYPE

(Optional) subtype

M_VALUES

(Optional) m_values

Command Mode

  • /exec

show fc2 classf

show fc2 classf [ __readonly__ { TABLE_fc2classf <HIX> <VSAN> <S_ID> <D_ID> <IFIDX> <R_A_TOV> <E_D_TOV> <F-SO> <RC> <RS> <CS> <EE> <2-SO> <RS> <3-SO> <RS> <EECNT> <TCCNT> <FCNT> <REFCNT> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

classf

show fc2 classf sessions

__readonly__

(Optional) Read only

TABLE_fc2classf

(Optional) show fc2 classf

HIX

(Optional) hix

VSAN

(Optional) vsan

S_ID

(Optional) sid

D_ID

(Optional) did

IFIDX

(Optional) ifidx

R_A_TOV

(Optional) r_a_tov

E_D_TOV

(Optional) e_d_tov

F-SO

(Optional) f-so

RC

(Optional) rc

RS

(Optional) rs

CS

(Optional) cs

EE

(Optional) ee

2-SO

(Optional) 2-so

RS

(Optional) rs

3-SO

(Optional) 3-so

RS

(Optional) rs

EECNT

(Optional) eecnt

TCCNT

(Optional) tccnt

FCNT

(Optional) fcnt

REFCNT

(Optional) refcnt

Command Mode

  • /exec

show fc2 exchange

show fc2 exchange [ __readonly__ { TABLE_ExchngInfo [ <ECB_INUSE> ] [ <ECB_DROPPED> ] [ <ECB_TOTAL> ] [ <ECB_MAX> ] } [ TABLE_fc2exchange <HIX> <VSAN> <X_ID> <OX_ID> <RX_ID> <O_ID> <R_ID> <ESTAT> <STATE> <SOCKET> <DIFINDEX> <CS> <TYPE> <SEQID> <TCNT> <RCNT> <LO> <HI> <SSTAT> <LOGIN> ] ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

exchange

show fc2 active exchanges

__readonly__

(Optional) Read only

TABLE_ExchngInfo

(Optional) ecb info

ECB_INUSE

(Optional) ecb in use

ECB_DROPPED

(Optional) ecb dropped

ECB_TOTAL

(Optional) ecb total

ECB_MAX

(Optional) ecb threshold

TABLE_fc2exchange

(Optional) show fc2 exchange

HIX

(Optional) hix

VSAN

(Optional) vsan

X_ID

(Optional) xid

OX_ID

(Optional) oxid

RX_ID

(Optional) rxid

O_ID

(Optional) o_id

R_ID

(Optional) r_id

ESTAT

(Optional) estat

STATE

(Optional) state

SOCKET

(Optional) socket

DIFINDEX

(Optional) dIFINDEX

CS

(Optional) cs

TYPE

(Optional) type

SEQID

(Optional) seqid

TCNT

(Optional) tcnt

RCNT

(Optional) rcnt

LO

(Optional) lo

HI

(Optional) hi

SSTAT

(Optional) sstat

LOGIN

(Optional) login

Command Mode

  • /exec

show fc2 exchresp

show fc2 exchresp [ __readonly__ { TABLE_fc2exchresp <HIX> <VSAN> <OX_ID> <S_ID> <CS> <SIFINDEX> <OX_ID2> <RX_ID2> <O_ID> <R_ID> <ESTAT> <STATE> <SOCKET> <TYPE> <SEQID> <TCNT> <RCNT> <LO> <HI> <SSTAT> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

exchresp

show fc2 active responder exchanges

__readonly__

(Optional) Read only

TABLE_fc2exchresp

(Optional) show fc2 exchresp

HIX

(Optional) hix

VSAN

(Optional) vsan

OX_ID

(Optional) oxid

S_ID

(Optional) sid

CS

(Optional) cs

SIFINDEX

(Optional) sifindex

OX_ID2

(Optional) oxid

RX_ID2

(Optional) rxid

O_ID

(Optional) oid

R_ID

(Optional) rid

ESTAT

(Optional) estat

STATE

(Optional) state

SOCKET

(Optional) socket

TYPE

(Optional) type

SEQID

(Optional) seqid

TCNT

(Optional) tcnt

RCNT

(Optional) rcnt

LO

(Optional) lo

HI

(Optional) hi

SSTAT

(Optional) sstat

Command Mode

  • /exec

show fc2 flogi

show fc2 flogi [ __readonly__ { TABLE_fc2flogi <HIX> <VSAN> <S_ID> <FLOGI> <IFINDEX> <TYPE> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

flogi

show fc2 flogi table

__readonly__

(Optional) Read only

TABLE_fc2flogi

(Optional) show fc2 flogi

HIX

(Optional) hix

VSAN

(Optional) vsan

S_ID

(Optional) sid

FLOGI

(Optional) flogi

IFINDEX

(Optional) ifindex

TYPE

(Optional) type

Command Mode

  • /exec

show fc2 nport

show fc2 nport [ __readonly__ { TABLE_fc2nport <REF> <VSAN> <D_ID> <MASK> <FL> <ST> <IFINDEX> <CF> <TC> <2-SO> <IC> <RC> <RS> <CS> <EE> <3-SO> <3-SO-IC> <3-SO-RC> <3-SO-RS> <3-SO-CS> <3-SO-EE> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

nport

show fc2 local nports

__readonly__

(Optional) Read only

TABLE_fc2nport

(Optional) show fc2 nport

REF

(Optional) ref

VSAN

(Optional) vsan

D_ID

(Optional) did

MASK

(Optional) mask

FL

(Optional) fl

ST

(Optional) st

IFINDEX

(Optional) ifindex

CF

(Optional) cf

TC

(Optional) tc

2-SO

(Optional) 2so

IC

(Optional) ic

RC

(Optional) rc

RS

(Optional) rs

CS

(Optional) cs

EE

(Optional) ee

3-SO

(Optional) 3so

3-SO-IC

(Optional) 3so-ic

3-SO-RC

(Optional) 3so-rc

3-SO-RS

(Optional) 3so-rs

3-SO-CS

(Optional) 3so-cs

3-SO-EE

(Optional) 3so-ee

Command Mode

  • /exec

show fc2 plogi

show fc2 plogi [ __readonly__ { TABLE_fc2plogi <HIX> <ADDRESS> <VSAN> <S_ID> <D_ID> <IF_INDEX> <FL> <STATE> <CF> <TC> <2-SO> <IC> <RC> <RS> <CS> <EE> <3-SO> <3SO_IC> <3SO_RC> <3SO_RS> <3SO_CS> <3SO_EE> <EECNT> <TCCNT> <2CNT> <3CNT> <REFCNT> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

plogi

show fc2 plogi sessions

__readonly__

(Optional) Read only

TABLE_fc2plogi

(Optional) show fc2 plogi

HIX

(Optional) hix

ADDRESS

(Optional) address

VSAN

(Optional) vsan

S_ID

(Optional) sid

D_ID

(Optional) did

IF_INDEX

(Optional) ifindex

FL

(Optional) fl

STATE

(Optional) state

CF

(Optional) cf

TC

(Optional) tc

2-SO

(Optional) 2so

IC

(Optional) ic

RC

(Optional) rc

RS

(Optional) rs

CS

(Optional) cs

EE

(Optional) ee

3-SO

(Optional) 3so

3SO_IC

(Optional) ic

3SO_RC

(Optional) rc

3SO_RS

(Optional) rs

3SO_CS

(Optional) cs

3SO_EE

(Optional) ee

EECNT

(Optional) eecnt

TCCNT

(Optional) TCCNT

2CNT

(Optional) 2cnt

3CNT

(Optional) 3cnt

REFCNT

(Optional) refcnt

Command Mode

  • /exec

show fc2 plogi_pwwn

show fc2 plogi_pwwn [ __readonly__ { TABLE_fc2plogi_pwwn <HIX> <ADDRESS> <VSAN> <S_ID> <D_ID> <IFINDEX> <FL> <STATE> <PWWN> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

plogi_pwwn

show fc2 plogi pwwn entries

__readonly__

(Optional) Read only

TABLE_fc2plogi_pwwn

(Optional) show fc2 plogi_pwwn

HIX

(Optional) hix

ADDRESS

(Optional) address

VSAN

(Optional) vsan

S_ID

(Optional) s_id

D_ID

(Optional) d_id

IFINDEX

(Optional) ifindex

FL

(Optional) fl

STATE

(Optional) state

PWWN

(Optional) pwwn

Command Mode

  • /exec

show fc2 port brief

show fc2 port brief [ __readonly__ { TABLE_fc2portbrief <BAD_FRAME_RX> } [ TABLE_FCSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] [ TABLE_LBSTAT <IX> <ST> <MOD> <EMUL> <TXLBPKTS> <TXLBDROP> <RXLBPKTS> <RXLBDROP> ] [ TABLE_VFCSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] [ TABLE_VFCPOSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] [ TABLE_VFCSLOTSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

port

show fc2 physical port table

brief

display only active port counters

__readonly__

(Optional) Read only

TABLE_fc2portbrief

(Optional) bad frames received

BAD_FRAME_RX

(Optional) fc2 bad frames rx

TABLE_FCSTAT

(Optional) FC Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

TABLE_LBSTAT

(Optional) LB Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXLBPKTS

(Optional) tx lb packets

TXLBDROP

(Optional) tx lb drops

RXLBPKTS

(Optional) rx lb packets

RXLBDROP

(Optional) rx lb drop

TABLE_VFCSTAT

(Optional) VFC Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

TABLE_VFCPOSTAT

(Optional) VFC po Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

TABLE_VFCSLOTSTAT

(Optional) VFC slot Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

Command Mode

  • /exec

show fc2 port drops

show fc2 port drops [ __readonly__ [ TABLE_FCSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] [ TABLE_LBSTAT <IX> <ST> <MOD> <EMUL> <TXLBPKTS> <TXLBDROP> <RXLBPKTS> <RXLBDROP> ] [ TABLE_VFCSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] [ TABLE_VFCPOSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] [ TABLE_VFCSLOTSTAT <IX> <ST> <MOD> <EMUL> <TXPKTS> <TXDROP> <TXERR> <RXPKTS> <RXDROP> ] ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

port

show fc2 physical port table

drops

display active port drop counters

__readonly__

(Optional) Read only

TABLE_FCSTAT

(Optional) FC Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

TABLE_LBSTAT

(Optional) LB Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXLBPKTS

(Optional) tx lb packets

TXLBDROP

(Optional) tx lb drops

RXLBPKTS

(Optional) rx lb packets

RXLBDROP

(Optional) rx lb drop

TABLE_VFCSTAT

(Optional) VFC Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

TABLE_VFCPOSTAT

(Optional) VFC po Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

TABLE_VFCSLOTSTAT

(Optional) VFC slot Stat table

IX

(Optional) index

ST

(Optional) status

MOD

(Optional) mode

EMUL

(Optional) TEemul

TXPKTS

(Optional) txpackets

TXDROP

(Optional) txdrops

TXERR

(Optional) txerrorcnt

RXPKTS

(Optional) rx packets

RXDROP

(Optional) rx drop

Command Mode

  • /exec

show fc2 port state

show fc2 port state [ __readonly__ [ TABLE_FCPORTSTATE [ <PORT_STRING> ] [ <PORT_NO> ] [ <UP_DOWN_CNTR> ] [ [ <UP_STRING> ] + [ <UP_TIME> ] + [ <UP_REFTIME> ] + [ <DOWN_STRING> ] + [ <DOWN_TIME> ] + [ <DOWN_REFTIME> ] + ] + ] [ TABLE_VFCPORTSTATE [ <PORT_STRING> ] [ <PORT_NO> ] [ <UP_DOWN_CNTR> ] [ [ <UP_STRING> ] + [ <UP_TIME> ] + [ <UP_REFTIME> ] + [ <DOWN_STRING> ] + [ <DOWN_TIME> ] + [ <DOWN_REFTIME> ] + ] + ] [ TABLE_VFCPOPORTSTATE [ <PORT_STRING> ] [ <PORT_NO> ] [ <UP_DOWN_CNTR> ] [ [ <UP_STRING> ] + [ <UP_TIME> ] + [ <UP_REFTIME> ] + [ <DOWN_STRING> ] + [ <DOWN_TIME> ] + [ <DOWN_REFTIME> ] + ] + ] [ TABLE_VFCPORTSLOTSTATE [ <PORT_STRING> ] [ <PORT_NO> ] [ <UP_DOWN_CNTR> ] [ [ <UP_STRING> ] + [ <UP_TIME> ] + [ <UP_REFTIME> ] + [ <DOWN_STRING> ] + [ <DOWN_TIME> ] + [ <DOWN_REFTIME> ] + ] + ] ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

port

show fc2 physical port table

state

display port state history

__readonly__

(Optional) Read only

TABLE_FCPORTSTATE

(Optional) fc port state change history

PORT_STRING

(Optional) port name

PORT_NO

(Optional) port number

UP_DOWN_CNTR

(Optional) up-down counter

UP_STRING

(Optional) up

UP_TIME

(Optional) up time

UP_REFTIME

(Optional) up from

DOWN_STRING

(Optional) down string

DOWN_TIME

(Optional) down time

DOWN_REFTIME

(Optional) down from

TABLE_VFCPORTSTATE

(Optional) vfc port state change history

PORT_STRING

(Optional) port name

PORT_NO

(Optional) port number

UP_DOWN_CNTR

(Optional) up-down counter

UP_STRING

(Optional) up

UP_TIME

(Optional) up time

UP_REFTIME

(Optional) up from

DOWN_STRING

(Optional) down string

DOWN_TIME

(Optional) down time

DOWN_REFTIME

(Optional) down from

TABLE_VFCPOPORTSTATE

(Optional) vfc po port state change history

PORT_STRING

(Optional) port name

PORT_NO

(Optional) port number

UP_DOWN_CNTR

(Optional) up-down counter

UP_STRING

(Optional) up

UP_TIME

(Optional) up time

UP_REFTIME

(Optional) up from

DOWN_STRING

(Optional) down string

DOWN_TIME

(Optional) down time

DOWN_REFTIME

(Optional) down from

TABLE_VFCPORTSLOTSTATE

(Optional) vfc port slot state change history

PORT_STRING

(Optional) port name

PORT_NO

(Optional) port number

UP_DOWN_CNTR

(Optional) up-down counter

UP_STRING

(Optional) up

UP_TIME

(Optional) up time

UP_REFTIME

(Optional) up from

DOWN_STRING

(Optional) down string

DOWN_TIME

(Optional) down time

DOWN_REFTIME

(Optional) down from

Command Mode

  • /exec

show fc2 socket

show fc2 socket [ __readonly__ { TABLE_fc2socket <SOCKET> <REFCNT> <PROTOCOL> <FLAGS> <PID> <RCVBUF> <RMEM_USED> <QLEN> <NOTSK> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

socket

show fc2 active sockets

__readonly__

(Optional) Read only

TABLE_fc2socket

(Optional) show fc2 socket

SOCKET

(Optional) socket

REFCNT

(Optional) refcnt

PROTOCOL

(Optional) protocol

FLAGS

(Optional) flags

PID

(Optional) pid

RCVBUF

(Optional) rcvbuf

RMEM_USED

(Optional) rmem_used

QLEN

(Optional) qlen

NOTSK

(Optional) not_sk

Command Mode

  • /exec

show fc2 sockexch

show fc2 sockexch [ __readonly__ { TABLE_fc2sockexch <SOCKET> <VSAN> <X_ID> <OX_ID> <RX_ID> <O_ID> <R_ID> <ESTAT> <STATE> <CS> <TYPE> <SK> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

sockexch

show fc2 active exchanges for each socket

__readonly__

(Optional) Read only

TABLE_fc2sockexch

(Optional) show fc2 sockexch

SOCKET

(Optional) socket

VSAN

(Optional) vsan

X_ID

(Optional) x_id

OX_ID

(Optional) oxid

RX_ID

(Optional) rxid

O_ID

(Optional) o_id

R_ID

(Optional) r_id

ESTAT

(Optional) estat

STATE

(Optional) state

CS

(Optional) cs

TYPE

(Optional) type

SK

(Optional) sk

Command Mode

  • /exec

show fc2 socknotify

show fc2 socknotify [ __readonly__ { TABLE_fc2socknotify <SOCKET> <ADDRESS> <REF> <VSAN> <D_ID> <MASK> <FL> <ST> <IFINDEX> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

socknotify

show fc2 local nport plogi/logo notifications per each socket

__readonly__

(Optional) Read only

TABLE_fc2socknotify

(Optional) show fc2 socknotify

SOCKET

(Optional) socket

ADDRESS

(Optional) address

REF

(Optional) ref

VSAN

(Optional) vsan

D_ID

(Optional) d_id

MASK

(Optional) mask

FL

(Optional) fl

ST

(Optional) st

IFINDEX

(Optional) ifindex

Command Mode

  • /exec

show fc2 socknport

show fc2 socknport [ __readonly__ { TABLE_fc2socknport <SOCKET> <ADDRESS> <REF> <VSAN> <D_ID> <MASK> <FL> <ST> <IFINDEX> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

socknport

show fc2 local nports per each socket

__readonly__

(Optional) Read only

TABLE_fc2socknport

(Optional) show fc2 socknport

SOCKET

(Optional) socket

ADDRESS

(Optional) address

REF

(Optional) ref

VSAN

(Optional) vsan

D_ID

(Optional) d_id

MASK

(Optional) mask

FL

(Optional) fl

ST

(Optional) st

IFINDEX

(Optional) ifindex

Command Mode

  • /exec

show fc2 vsan

show fc2 vsan [ __readonly__ { TABLE_fc2vsan <VSAN> <X_ID> <E_D_TOV> <R_A_TOV> <WWN> <IOP_MODE> } ]

Syntax Description

show

Show running system information

fc2

show fc2 tables and statistics

vsan

show fc2 vsan table

__readonly__

(Optional) Read only

TABLE_fc2vsan

(Optional) show fc2 vsan

VSAN

(Optional) vsan

X_ID

(Optional) xid

E_D_TOV

(Optional) e_d_tov

R_A_TOV

(Optional) r_a_tov

WWN

(Optional) wwn

IOP_MODE

(Optional) iop_mode

Command Mode

  • /exec

show fcalias

show fcalias [ [ name <s0> ] [ [ pending ] [ vsan <i0> ] ] ]

Syntax Description

show

Show running system information

fcalias

Fcalias show commands

name

(Optional) Show members of a specified fcalias

s0

(Optional) Enter the name of fcalias

pending

(Optional) Show members of a specified fcalias in session

vsan

(Optional) Show aliases belonging to the specified VSAN

i0

(Optional) VSAN id range

Command Mode

  • /exec

show fcdomain

show fcdomain

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

Command Mode

  • /exec

show fcdomain address-allocation

show fcdomain address-allocation [ { cache | vsan <i0> } ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

address-allocation

Show statistics for the fcid allocation

cache

(Optional) Show cache content for the fcid allocation

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain allowed

show fcdomain allowed [ vsan <i0> ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

allowed

Show list of allowed domain IDs

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain domain-list

show fcdomain domain-list [ vsan <i0> ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

domain-list

Show list of domain IDs granted by the principal sw

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain fcid persistent

show fcdomain fcid persistent [ { unused [ vsan <i0> ] | vsan1 <i1> } ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

fcid

Show persistent FCIDs (across reboot)

persistent

Show persistent FCIDs (across reboot)

unused

(Optional) Show unused persistent FCIDs (across reboot)

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

vsan1

(Optional) Specify the vsan id

i1

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain pending-diff

show fcdomain pending-diff [ vsan <i0> ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

pending-diff

Show the difference between running and pending configuration

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain pending

show fcdomain pending [ vsan <i0> ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

pending

Show the pending configuration

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain session-status

show fcdomain session-status [ vsan <i0> ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

session-status

Show the last action performed by fcdomain

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain statistics

show fcdomain statistics [ { interface <if0> [ vsan <i0> ] | vsan1 <i1> } ]

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

statistics

Show the statistics of fcdomain

interface

(Optional) Specify the fibre channel interface

if0

(Optional)

vsan

(Optional) Specify the vsan id

i0

(Optional) VSAN id

vsan1

(Optional) Specify the vsan id

i1

(Optional) VSAN id

Command Mode

  • /exec

show fcdomain status

show fcdomain status

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

status

Show all vsan-independent information in fcdomain

Command Mode

  • /exec

show fcdomain vsan

show fcdomain vsan <i0>

Syntax Description

show

Show running system information

fcdomain

Show fcdomain information

vsan

Specify the vsan id

i0

VSAN id

Command Mode

  • /exec

show fcdroplatency

show fcdroplatency [ { network | switch } ] [ __readonly__ [ <switch_latency> ] [ <global_network_latency> ] [ TABLE_vsan_network_latency { <vsan-no> <network-latency> } ] ]

Syntax Description

show

Show running system information

fcdroplatency

show switch or network latency

network

(Optional) network latency in milliseconds

switch

(Optional) switch latency in milliseconds

__readonly__

(Optional)

switch_latency

(Optional) Switch latency value

global_network_latency

(Optional) global network latency value

TABLE_vsan_network_latency

(Optional) VSAN specific network latency settings

vsan-no

(Optional) vsan number

network-latency

(Optional) VSAN specific network latency

Command Mode

  • /exec

show fcid-allocation area

show fcid-allocation area

Syntax Description

show

Show running system information

fcid-allocation

Show information about fcid-allocation list

area

Show information about fcid-allocation list

Command Mode

  • /exec

show fcid-allocation company-id-from-wwn

show fcid-allocation company-id-from-wwn <wwn0>

Syntax Description

show

Show running system information

fcid-allocation

Show information about fcid-allocation list

company-id-from-wwn

Company id (or OUI).

wwn0

Enter WWN to extract company_id/oui

Command Mode

  • /exec

show fcns database

show fcns database [ { detail [ vsan <i0> ] | domain <i1> [ { detail [ vsan1 <i2> ] | vsan2 <i3> } ] | fcid <fcid4> { detail2 vsan3 <i5> | vsan4 <i6> } | local [ { detail1 [ vsan5 <i7> ] | vsan6 <i8> } ] | npv [ { detail1 [ vsan7 <i9> ] | node_wwn <wwn10> [ vsan8 <i11> ] | vsan9 <i12> } ] | proxy-host { detail4 vsan10 <i13> | vsan11 <i14> } | vsan12 <i15> } ]

Syntax Description

show

Show running system information

fcns

show name server tables

database

show name server database

detail

(Optional) show all objects in each entry

vsan

(Optional) show local entries for the given vsan(s)

i0

(Optional) VSAN id range

domain

(Optional) show entries in a domain

i1

(Optional) domain-id

detail

(Optional) show all objects in each entry

vsan1

(Optional) show entries for a domain for the given vsan(s)

i2

(Optional) VSAN id range

vsan2

(Optional) show entries for a domain for the given vsan(s)

i3

(Optional) VSAN id range

fcid

(Optional) show entry for the given port

fcid4

(Optional) enter FCID

detail2

(Optional) show all objects in the entry

vsan3

(Optional) show port entry for the given vsan

i5

(Optional) VSAN id

vsan4

(Optional) show port entry for the given vsan

i6

(Optional) VSAN id

local

(Optional) show local entries

detail1

(Optional) show all objects in each entry

vsan5

(Optional) show local entries for the given vsan(s)

i7

(Optional) VSAN id range

vsan6

(Optional) show local entries for the given vsan(s)

i8

(Optional) VSAN id range

npv

(Optional) show n-port virtualization (npv) entries

detail1

(Optional) show all objects in each entry

vsan7

(Optional) show npv entries for the given vsan(s)

i9

(Optional) VSAN id range

node_wwn

(Optional) show end-devices logged in via an npv node

wwn10

(Optional) Node WWN of NPV

vsan8

(Optional) show npv entries for the given vsan(s)

i11

(Optional) VSAN id range

vsan9

(Optional) show npv entries for the given vsan(s)

i12

(Optional) VSAN id range

proxy-host

(Optional) show entry for the proxy-host

detail4

(Optional) show all objects in the entry

vsan10

(Optional) show port entry for the given vsan

i13

(Optional) VSAN id

vsan11

(Optional) show port entry for the given vsan

i14

(Optional) VSAN id

vsan12

(Optional) show entries for the given vsan(s)

i15

(Optional) VSAN id range

Command Mode

  • /exec

show fcns statistics

show fcns statistics [ { detail [ vsan <i0> ] | vsan1 <i1> } ]

Syntax Description

show

Show running system information

fcns

show name server tables

statistics

show name server statistics

detail

(Optional) show detailed statistics

vsan

(Optional) show detailed statistics for the vsan(s)

i0

(Optional) VSAN id range

vsan1

(Optional) show statistics for the vsan(s)

i1

(Optional) VSAN id range

Command Mode

  • /exec

show fcoe-npv issu-impact

show fcoe-npv issu-impact [ __readonly__ { <is_impact> } [ TABLE_interface <vfc_intf> <fc_id> ] ]

Syntax Description

show

Show running system informationrunning system information

fcoe-npv

feature fcoe-npv

issu-impact

Show feature fcoe-npv config issues if attempting to do non-disruptive ISSU

__readonly__

(Optional) Read Only

is_impact

(Optional) show issu impact

TABLE_interface

(Optional) show fcoe database

vfc_intf

(Optional) vfc port Interface index

fc_id

(Optional) vfc port FCID

Command Mode

  • /exec

show fcoe

show fcoe [ __readonly__ { TABLE_fcf <fcf_if_index> <fcf_mac> <fc_map> <fcf_priority> <fka_Advertisement> } [ TABLE_vfc <vfc_name> <vfcf_mac> ] ]

Syntax Description

show

Show running system information

fcoe

Show FCOE paramaters

__readonly__

(Optional) Read Only

TABLE_fcf

(Optional) fcf table

fcf_if_index

(Optional) fcf if index

fcf_mac

(Optional) fcf mac

fc_map

(Optional) fc map

fcf_priority

(Optional) fcf priority

fka_Advertisement

(Optional) fka Advertisement

TABLE_vfc

(Optional) vfc details table for sup

vfc_name

(Optional) vfc name

vfcf_mac

(Optional) vfcf mac

Command Mode

  • /exec

show fcoe database

show fcoe database [ __readonly__ { TABLE_interface <interface> [ <fcid> ] [ <port_name> ] <mac_address> } <flogi_count> [ TABLE_veport <interface> <mac_address> <vsan> ] ]

Syntax Description

show

Show running system information

fcoe

Show FCOE paramaters

database

Show FCOE database

__readonly__

(Optional) Read Only

interface

(Optional) Interface index

TABLE_interface

(Optional) show fcoe database

fcid

(Optional) fcid

port_name

(Optional) port name

mac_address

(Optional) mac address

interface

(Optional) ve port Interface index

TABLE_veport

(Optional) ve port details

mac_address

(Optional) ve port mac address

flogi_count

(Optional) flogi_count

vsan

(Optional) ve port VSAN trunking

Command Mode

  • /exec

show fcs database

show fcs database [ vsan <i0> ]

Syntax Description

show

Show running system information

database

Show local database of FCS

vsan

(Optional) Show local database for a VSAN

i0

(Optional) VSAN range

Command Mode

  • /exec

show fcs ie

show fcs ie [ { nwwn <wwn0> vsan <i1> | vsan1 <i2> } ]

Syntax Description

show

Show running system information

ie

Show Interconnect Element Objects Information

nwwn

(Optional) IE WWN

wwn0

(Optional) IE WWN

vsan

(Optional) VSAN id of IE

i1

(Optional) VSAN id

vsan1

(Optional) VSAN id of IE

i2

(Optional) VSAN range

Command Mode

  • /exec

show fcs platform

show fcs platform { name <s0> vsan <i0> | vsan1 <i1> }

Syntax Description

show

Show running system information

platform

Show Platform Objects Information

name

Platform Name

s0

Platform name string

vsan

VSAN id of the platform

i0

VSAN id

vsan1

VSAN id of the platform

i1

VSAN range

Command Mode

  • /exec

show fcs port

show fcs port { pwwn <wwn0> vsan <i1> | vsan1 <i2> }

Syntax Description

show

Show running system information

port

Show Port Objects Information

pwwn

Port WWN

wwn0

Port WWN

vsan

VSAN id of the port

i1

VSAN id

vsan1

VSAN id of the port

i2

VSAN range

Command Mode

  • /exec

show fcs statistics

show fcs statistics [ vsan <i0> ]

Syntax Description

show

Show running system information

statistics

Show statistics for FCS packets.

vsan

(Optional) Show statistics for a VSAN

i0

(Optional) VSAN range

Command Mode

  • /exec

show fcs vsan

show fcs vsan

Syntax Description

show

Show running system information

vsan

Show list of all the VSANs and plat-check-mode for each

Command Mode

  • /exec

show fctimer

show fctimer [ __readonly__ { <F_S_TOV> <D_S_TOV> <E_D_TOV> <R_A_TOV> } ]

Syntax Description

show

show running system information

fctimer

show Fibre Channel timers

__readonly__

(Optional) Read only

F_S_TOV

(Optional) F_S_TOV

D_S_TOV

(Optional) D_S_TOV

E_D_TOV

(Optional) E_D_TOV

R_A_TOV

(Optional) R_A_TOV

Command Mode

  • /exec

show fctimer D_S_TOV

show fctimer D_S_TOV [ vsan <i0> ] [ __readonly__ [ TABLE_D_S_TOV [ <vsan-no> ] <D_S_TOV> ] [ <non-exist-vsan> ] ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

D_S_TOV

D_S_TOV in milliseconds

vsan

(Optional) Specify VSAN id

i0

(Optional) VSAN id range

__readonly__

(Optional)

TABLE_D_S_TOV

(Optional) table D_S_TOV

vsan-no

(Optional) vsan number

D_S_TOV

(Optional) D_S_TOV

non-exist-vsan

(Optional) non configured vsans

Command Mode

  • /exec

show fctimer E_D_TOV

show fctimer E_D_TOV [ vsan <i0> ] [ __readonly__ [ TABLE_E_D_TOV [ <vsan-no> ] <E_D_TOV> ] [ <non-exist-vsan> ] ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

E_D_TOV

E_D_TOV in milliseconds

vsan

(Optional) Specify VSAN id

i0

(Optional) VSAN id range

__readonly__

(Optional)

TABLE_E_D_TOV

(Optional) table

vsan-no

(Optional) vsan number

E_D_TOV

(Optional) E_D_TOV

non-exist-vsan

(Optional) not exist vsans

Command Mode

  • /exec

show fctimer F_S_TOV

show fctimer F_S_TOV [ vsan <i0> ] [ __readonly__ [ TABLE_F_S_TOV [ <vsan-no> ] <F_S_TOV> ] [ <non-exist-vsan> ] ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

F_S_TOV

F_S_TOV in milliseconds

vsan

(Optional) Specify VSAN id

i0

(Optional) VSAN id range

__readonly__

(Optional)

TABLE_F_S_TOV

(Optional) table

vsan-no

(Optional) vsan number

F_S_TOV

(Optional) F_S_TOV

non-exist-vsan

(Optional) not exist vsans

Command Mode

  • /exec

show fctimer R_A_TOV

show fctimer R_A_TOV [ vsan <i0> ] [ __readonly__ [ TABLE_R_A_TOV [ <vsan-no> ] <R_A_TOV> ] [ <non-exist-vsan> ] ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

R_A_TOV

R_A_TOV in milliseconds

vsan

(Optional) Specify VSAN id

i0

(Optional) VSAN id range

__readonly__

(Optional)

TABLE_R_A_TOV

(Optional) table

vsan-no

(Optional) vsan number

R_A_TOV

(Optional) R_A_TOV

non-exist-vsan

(Optional) non exist vsans

Command Mode

  • /exec

show fctimer last action status

show fctimer last action status [ __readonly__ [ <vsan> ] <last_action_timestamp> <last_action> <last_action_result> <last_action_failure_reason> ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

last

Show the status of the last cfs commit/abort operation

action

Show the status of the last cfs commit/abort operation

status

Show the status of the last cfs commit/abort operation

__readonly__

(Optional) Readonly

vsan

(Optional) Vsan

last_action_timestamp

(Optional) Last action timestamp

last_action

(Optional) Last action

last_action_result

(Optional) Last action result

last_action_failure_reason

(Optional) Last action failure reason

Command Mode

  • /exec

show fctimer pending-diff

show fctimer pending-diff [ __readonly__ <status_fctimer> ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

pending-diff

Show the difference between pending database and running config

__readonly__

(Optional)

status_fctimer

(Optional) Show the difference between pending database and running config

Command Mode

  • /exec

show fctimer pending

show fctimer pending [ __readonly__ <status_fctimer> ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

pending

Show the status of pending fctimer commands

__readonly__

(Optional)

status_fctimer

(Optional) Show the status of pending fctimer commands

Command Mode

  • /exec

show fctimer session status

show fctimer session status [ __readonly__ [ <vsan> ] <last_action_timestamp> <last_action> <last_action_result> <last_action_failure_reason> ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

session

Show the state of fctimer cfs session

status

Show the status of the last cfs commit/abort operation

__readonly__

(Optional) Readonly

vsan

(Optional) Vsan

last_action_timestamp

(Optional) Last action timestamp

last_action

(Optional) Last action

last_action_result

(Optional) Last action result

last_action_failure_reason

(Optional) Last action failure reason

Command Mode

  • /exec

show fctimer status

show fctimer status [ __readonly__ <Distribution> ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

status

cfs distribution is enabled or disabled

__readonly__

(Optional) read only

Distribution

(Optional) distribution

Command Mode

  • /exec

show fctimer vsan

show fctimer vsan <i0> [ __readonly__ { TABLE_fctimer <vsan-no> <F_S_TOV> <D_S_TOV> <E_D_TOV> <R_A_TOV> } [ <non-exist-vsan> ] ]

Syntax Description

show

Show running system information

fctimer

show Fibre Channel timers

vsan

Specify VSAN id

i0

VSAN id range

__readonly__

(Optional) Read only

TABLE_fctimer

(Optional) table

vsan-no

(Optional) vsan number

F_S_TOV

(Optional) F_S_TOV

D_S_TOV

(Optional) D_S_TOV

E_D_TOV

(Optional) E_D_TOV

R_A_TOV

(Optional) R_A_TOV

non-exist-vsan

(Optional) non exist vsans

Command Mode

  • /exec

show fdmi database

show fdmi database

Syntax Description

show

Show running system information

fdmi

Show fdmi information

database

show fdmi database

Command Mode

  • /exec

show fdmi database detail

show fdmi database detail

Syntax Description

show

Show running system information

fdmi

Show fdmi information

database

show fdmi database

detail

show all objects in each entry

Command Mode

  • /exec

show fdmi database detail hba-id vsan

show fdmi database detail hba-id <wwn0> vsan <i1>

Syntax Description

show

Show running system information

fdmi

Show fdmi information

database

show fdmi database

detail

show all objects in each entry

hba-id

show entries for the given HBA id

wwn0

HBA id

vsan

show HBA id the given vsan

i1

VSAN id

Command Mode

  • /exec

show fdmi database detail vsan

show fdmi database detail vsan <i0>

Syntax Description

show

Show running system information

fdmi

Show fdmi information

database

show fdmi database

detail

show all objects in each entry

vsan

show entries for the given vsan(s)

i0

VSAN id range

Command Mode

  • /exec

show fdmi database vsan

show fdmi database vsan <i0>

Syntax Description

show

Show running system information

fdmi

Show fdmi information

database

show fdmi database

vsan

show entries for the given vsan(s)

i0

VSAN id range

Command Mode

  • /exec

show fdmi suppress-updates

show fdmi suppress-updates

Syntax Description

show

Show running system information

fdmi

Show fdmi information

suppress-updates

Show vsans on which updates are suppressed

Command Mode

  • /exec

show feature-set

show feature-set [ <name> ] [ <id> ] [ __readonly__ TABLE_cfcFeatureSetTable <cfcFeatureSetIndex> <cfcFeatureSetName> <cfcFeatureSetAction> <cfcFeatureSetLastAction> <cfcFeatureSetLastActionResult> <cfcFeatureSetLastFailureReason> <cfcFeatureSetOpStatus> <cfcFeatureSetOpStatusReason> ]

Syntax Description

show

Show running system information

feature-set

Show feature set status

name

(Optional) feature-set name

id

(Optional) feature-set id

__readonly__

(Optional)

TABLE_cfcFeatureSetTable

(Optional) feature-set table

cfcFeatureSetIndex

(Optional) feature-set table index

cfcFeatureSetName

(Optional) feature-set name

cfcFeatureSetAction

(Optional) action

cfcFeatureSetLastAction

(Optional) last action

cfcFeatureSetLastActionResult

(Optional) last action result

cfcFeatureSetLastFailureReason

(Optional) last failure reason

cfcFeatureSetOpStatus

(Optional) operation status

cfcFeatureSetOpStatusReason

(Optional) operation status

Command Mode

  • /exec

show feature-set services

show feature-set services <s0> [ __readonly__ [ { TABLE_services <service_name> } ] { <count> <feature_set> } ]

Syntax Description

show

Show running system information

feature-set

Show feature set status

services

Show services in feature set

__readonly__

(Optional)

TABLE_services

(Optional) all service names in feature set

service_name

(Optional) name of the service

count

(Optional) number of services in the feature set

feature_set

(Optional) feature set name

s0

Name of feature set

Command Mode

  • /exec

show feature

show feature [ __readonly__ [ { TABLE_cfcFeatureCtrlTable <cfcFeatureCtrlIndex2> <cfcFeatureCtrlInstanceNum2> <cfcFeatureCtrlName2> <cfcFeatureCtrlAction2> <cfcFeatureCtrlLastAction2> <cfcFeatureCtrlLastActionResult2> <cfcFeatureCtrlLastFailureReason2> <cfcFeatureCtrlOpStatus2> <cfcFeatureCtrlOpStatusReason2> <cfcFeatureCtrlTag2> } ] ]

Syntax Description

show

Show running system information

feature

Show feature status

__readonly__

(Optional)

TABLE_cfcFeatureCtrlTable

(Optional) feature table

cfcFeatureCtrlIndex2

(Optional) feature table index

cfcFeatureCtrlInstanceNum2

(Optional) instance number

cfcFeatureCtrlName2

(Optional) feature name

cfcFeatureCtrlAction2

(Optional) Action to be triggered for the feature

cfcFeatureCtrlLastAction2

(Optional) Last action triggered for the feature

cfcFeatureCtrlLastActionResult2

(Optional) The result of execution of the last action

cfcFeatureCtrlLastFailureReason2

(Optional) Failure Reason

cfcFeatureCtrlOpStatus2

(Optional) operation status

cfcFeatureCtrlOpStatusReason2

(Optional) Reason for current operation status

cfcFeatureCtrlTag2

(Optional) Name of the instance in string format in case of multinstance feature

Command Mode

  • /exec

show fex interface priority-flow-control

show fex { <fexnum> interface | interface [ <if_list> ] } priority-flow-control [ detail ] [ __readonly__ [ TABLE_pfc_interface <if_name_str> <admin> <oper> [ <oper_vl_bmap> ] [ <cos-list> ] <rx-stats> <tx-stats> [ <rx_ppp_cos_0> ] [ <rx_ppp_cos_1> ] [ <rx_ppp_cos_2> ] [ <rx_ppp_cos_3> ] [ <rx_ppp_cos_4> ] [ <rx_ppp_cos_5> ] [ <rx_ppp_cos_6> ] [ <rx_ppp_cos_7> ] [ <tx_ppp_cos_0> ] [ <tx_ppp_cos_1> ] [ <tx_ppp_cos_2> ] [ <tx_ppp_cos_3> ] [ <tx_ppp_cos_4> ] [ <tx_ppp_cos_5> ] [ <tx_ppp_cos_6> ] [ <tx_ppp_cos_7> ] ] ]

Syntax Description

show

commands to display

fex

Show FEX information

fexnum

FEX number

interface

Interface for displaying PFC information

if_list

(Optional) List of interfaces

priority-flow-control

Show interface PFC information

detail

(Optional) Show detailed per priority Tx/Rx PFC statistics

__readonly__

(Optional)

if_name_str

(Optional) interface name

TABLE_pfc_interface

(Optional) PFC information of an interface

admin

(Optional) PFC admin

oper

(Optional) PFC oper

oper_vl_bmap

(Optional) VL bitmap value

cos-list

(Optional) List of class-of-service values

Command Mode

  • /exec

show fhrp

show fhrp [ <intf> ] [ __readonly__ { TABLE_brief <intf_name> <intf_state> <ipv4_state> <ipv6_state> <hardware_status> <refcount> } ]

Syntax Description

fhrp

FHRP Show commands

show

Show running system information

intf

(Optional) Specify a single interface

__readonly__

(Optional)

TABLE_brief

(Optional) Show brief FHRP interface information

intf_name

(Optional) Interface name

intf_state

(Optional) Interface state

ipv4_state

(Optional) Interface IPv4 state

ipv6_state

(Optional) Interface IPv6 state

hardware_status

(Optional) Interface hardware status

refcount

(Optional) Interface refcount

Command Mode

  • /exec

show fhrp verbose

show fhrp [ <intf> ] verbose [ __readonly__ { TABLE_det <intf_name> <handle> <refcount> { TABLE_clients <client_id> <client_name> } <running> <expired> <v_retries> <v_time> <r_delay> <min_delay> <remaining_delay> <i_state> <ipv4_state> <ipv6_state> <h_state> <int_l2> } ]

Syntax Description

fhrp

FHRP Show commands

show

Show running system information

intf

(Optional) Specify a single interface

verbose

Display detailed information

__readonly__

(Optional)

TABLE_det

(Optional) Detailed FHRP interface information

intf_name

(Optional) Interface name

handle

(Optional) Interface handle

refcount

(Optional) Reference count

TABLE_clients

(Optional) FHRP clients present on interface

client_id

(Optional) FHRP client id

client_name

(Optional) FHRP client name

running

(Optional) Time verify up timer running

expired

(Optional) Verify up timer has expired

v_retries

(Optional) Verify retries

v_time

(Optional) Verify remaining time

r_delay

(Optional) Reload delay

min_delay

(Optional) Min delay

remaining_delay

(Optional) Remaining delay

i_state

(Optional) Interface state

ipv4_state

(Optional) Interface IPv4 state

ipv6_state

(Optional) Interface IPv6 state

h_state

(Optional) Interface hardware state

int_l2

(Optional) Interface is L2-only

Command Mode

  • /exec

show file

show file <uri0> [ cksum | md5sum | sha256sum | sha512sum ] [ __readonly__ { [ <file_content> ] + [ <file_content_cksum> ] [ <file_content_md5sum> ] [ <file_content_sha256sum> ] [ <file_content_sha512sum> ] } ]

Syntax Description

show

Show running system information

file

Displays content of files

uri0

Filename to be displayed

cksum

(Optional) Displays CRC checksum for a file

md5sum

(Optional) Displays MD5 checksum for a file

sha256sum

(Optional) Displays SHA256 checksum for a file

sha512sum

(Optional) Displays SHA512 checksum for a file

__readonly__

(Optional) Read only

file_content

(Optional) uri file content buffer string

file_content_cksum

(Optional) uri file content checksum

file_content_md5sum

(Optional) uri file content md5sum

file_content_sha256sum

(Optional) uri file content sha256sum

file_content_sha512sum

(Optional) uri file content sha512sum

Command Mode

  • /exec

show fips status

show fips status [ __readonly__ { operation_status <o_status> } { mode_state <m_state> } [ TABLE_sessions <lc_num> <lc_status> ] ]

Syntax Description

show

Show running system information

fips

Show if FIPS mode is enabled or disabled

status

Whether FIPS mode is enabled or disabled

__readonly__

(Optional)

operation_status

(Optional) run-time information about fips

o_status

(Optional) operational status of fips

mode_state

(Optional) mode state

m_state

(Optional) fips or non-fips state

TABLE_sessions

(Optional) all lc status

lc_num

(Optional) the lc number

lc_status

(Optional) the lc status

Command Mode

  • /exec

show flogi auto-area-list

show flogi auto-area-list

Syntax Description

show

Show running system information

flogi

Show information about FLOGI

auto-area-list

Show list of ouis that are allocated area.

Command Mode

  • /exec

show flogi database

show flogi database [ { details | [ fcid <fcid0> ] [ details ] | [ interface <if0> ] [ details ] | [ vsan <i1> ] [ details ] } ]

Syntax Description

show

Show running system information

flogi

Show information about FLOGI

database

Show information about FLOGI sessions

details

(Optional) details: shows fcid allocation details

fcid

(Optional) fcid: enter the fcid to be matched

fcid0

(Optional) Enter fcid

details

(Optional) details: shows fcid allocation details

interface

(Optional) interface id: enter the interface id of the port

if0

(Optional) Enter interface id

details

(Optional) details: shows fcid allocation details

vsan

(Optional) vsan id:Enter the vsan number

i1

(Optional) Enter vsan

details

(Optional) details: shows fcid allocation details

Command Mode

  • /exec

show flow cache

show flow cache [ ipv4 | ipv6 | ce ] [ __readonly__ TABLE_flow_cache <flow-type> <source-ip> <destination-ip> <bridge-domain-id> <source-port> <destination-port> <protocol> <ipv6-flowlabel> <byte-count> <packet-count> <tcp-flags> <tos> <if-id> <flow-start> <flow-end> <source-mac> <destination-mac> <ether-type> ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

cache

Show NetFlow Exporter Cache

ipv4

(Optional) Show ipv4 cache entries

ipv6

(Optional) Show ipv6 cache entries

ce

(Optional) Show ce cache entries

__readonly__

(Optional)

TABLE_flow_cache

(Optional) The XML flow cache table

flow-type

(Optional) Flow type - v4,v6 or MAC

source-ip

(Optional) Source IP

destination-ip

(Optional) Destination IP

bridge-domain-id

(Optional) Bridge Domain ID

source-port

(Optional) Source Port

destination-port

(Optional) Destination Port

protocol

(Optional) Protocol

ipv6-flowlabel

(Optional) Ipv6 flowlabel

byte-count

(Optional) Byte Count

packet-count

(Optional) Packet Count

tcp-flags

(Optional) TCP Flags

tos

(Optional) TOS

if-id

(Optional) IF ID

flow-start

(Optional) Flow Start Time

flow-end

(Optional) Flow End Time

source-mac

(Optional) Source MAC

destination-mac

(Optional) Destination MAC

ether-type

(Optional) Ether Type

Command Mode

  • /exec

show flow cache

show flow cache [ ipv4 | ipv6 | ce ] [ __readonly__ [ { TABLE_flow_cache <flow-cache-index> [ <flow-type> ] [ <source-ip> ] [ <destination-ip> ] [ <source-mac> ] [ <destination-mac> ] [ <bridge-domain-id> ] [ <ether-type> ] [ <source-port> ] [ <destination-port> ] [ <protocol> ] [ <ipv6-flowlabel> ] [ <byte-count> ] [ <packet-count> ] [ <tcp-flags> ] [ <tos> ] [ <if-id> ] [ <output-if-id> ] [ <flow-start> ] [ <flow-end> ] [ <profile> ] } ] ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

cache

Show NetFlow Exporter Cache

ipv4

(Optional) Show ipv4 cache entries

ipv6

(Optional) Show ipv6 cache entries

ce

(Optional) Show ce cache entries

__readonly__

(Optional)

TABLE_flow_cache

(Optional) The XML flow cache table

flow-cache-index

(Optional) Flow Index

flow-type

(Optional) Flow type - v4,v6 or MAC

source-ip

(Optional) Source IP

destination-ip

(Optional) Destination IP

source-mac

(Optional) Source MAC

destination-mac

(Optional) Destination MAC

bridge-domain-id

(Optional) Bridge Domain ID

ether-type

(Optional) Ether Type

source-port

(Optional) Source Port

destination-port

(Optional) Destination Port

protocol

(Optional) Protocol

ipv6-flowlabel

(Optional) Ipv6 flowlabel

byte-count

(Optional) Byte Count

packet-count

(Optional) Packet Count

tcp-flags

(Optional) TCP Flags

tos

(Optional) TOS

if-id

(Optional) IF ID

output-if-id

(Optional) OUTPUT IF ID

flow-start

(Optional) Flow Start Time

flow-end

(Optional) Flow End Time

profile

(Optional) Profile

Command Mode

  • /exec

show flow event

show flow event [ name ] [ { <eventname> } ] [ __readonly__ [ { TABLE_nfm_event <event> [ <description> ] <use_count> [ { TABLE_nfm_group <events> [ <buffer_drops> ] [ <fwd_drops> ] [ <acl_drops> ] [ <flow_count> ] [ <latency_threshold> ] [ <latency_unit> ] [ <latency_flow_count> ] [ <rcv_window_zero> ] [ <ip_df> ] [ <tos_value> ] [ <ttl_value> ] [ <max_burst_value> ] } ] } ] ]

Syntax Description

show

Show running system information

flow

Show Analytics information

event

Show Event Configuration

name

(Optional) Show the configuration for a specific Event

eventname

(Optional) Specify a event

__readonly__

(Optional)

TABLE_nfm_event

(Optional) Event Table

event

(Optional) Analytics event

description

(Optional) Description of Analytics event

use_count

(Optional) Use count of Analytics event

TABLE_nfm_group

(Optional)

events

(Optional) Drop or Latency type of events

buffer_drops

(Optional) Capture buffer-drops

fwd_drops

(Optional) Capture fwd-drops

acl_drops

(Optional) Capture acl-drops

flow_count

(Optional) Drop type flow count

latency_threshold

(Optional) Latency threshold value

latency_unit

(Optional) Unit for latency threshold measurement

latency_flow_count

(Optional) Latency type flow count

rcv_window_zero

(Optional) Capture Receive Window Zero events

ip_df

(Optional) Capture IpDf events

tos_value

(Optional) Type of Service value

ttl_value

(Optional) Time To Live value

max_burst_value

(Optional) Max Burst value

Command Mode

  • /exec

show flow exporter

show flow exporter [ name ] [ <exporter> ] [ __readonly__ { TABLE_flow_exporter <exporter> [ <description> ] [ <dest_intf> ] [ <dest> ] [ <vrf> ] [ <vrf_id> ] [ <vrf_resolved> ] [ <dest_udp> ] [ <events_dest_udp> ] [ <source_intf> ] [ <source_ip> ] [ <dscp> ] [ <exp_vers> ] [ <seqnum> ] [ <samp_table_to> ] [ <if_table_to> ] [ <stats_to> ] [ <temp_to> ] [ <rec_sent> ] [ <temp_sent> ] [ <pkts_sent> ] [ <bytes_sent> ] [ <dest_unreach> ] [ <buff_events> ] [ <pkts_drop_no_route> ] [ <pkts_drop_other> ] [ <pkts_drop_lc_rp> ] [ <pkts_drop_op_drops> ] [ <time_last_cleared> ] } ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

exporter

Show NetFlow Exporter Configuration and Statistics

name

(Optional) Show a specific Flow Exporter

exporter

(Optional) Specify an exporter

__readonly__

(Optional)

TABLE_flow_exporter

(Optional)

exporter

(Optional)

description

(Optional)

dest_intf

(Optional)

dest

(Optional)

vrf

(Optional)

vrf_id

(Optional)

vrf_resolved

(Optional)

dest_udp

(Optional)

events_dest_udp

(Optional)

source_intf

(Optional)

source_ip

(Optional)

dscp

(Optional)

seqnum

(Optional)

exp_vers

(Optional)

samp_table_to

(Optional)

if_table_to

(Optional)

stats_to

(Optional)

temp_to

(Optional)

rec_sent

(Optional)

temp_sent

(Optional)

pkts_sent

(Optional)

bytes_sent

(Optional)

dest_unreach

(Optional)

buff_events

(Optional)

pkts_drop_no_route

(Optional)

pkts_drop_other

(Optional)

pkts_drop_lc_rp

(Optional)

pkts_drop_op_drops

(Optional)

time_last_cleared

(Optional)

Command Mode

  • /exec

show flow filter

show flow filter [ __readonly__ [ { TABLE_flow_filter <name> <ipv4acl> <ipv6acl> } ] ]

Syntax Description

show

Show running system information

flow

Show Analytics information

filter

Show filter Configuration

__readonly__

(Optional)

TABLE_flow_filter

(Optional) flow filter data

name

(Optional) Filter Name

ipv4acl

(Optional) IPv4 ACL

ipv6acl

(Optional) IPv4 ACL

Command Mode

  • /exec

show flow interface

show flow { interface [ <intf> ] | vlan [ <vlan> ] } [ __readonly__ [ { TABLE_flow_interface [ <intf_name> ] [ <vlan_id> ] [ <filter> ] [ <v4in_mon_name> ] [ <v4in_direction> ] [ <v4in_profile_id> ] [ <v6in_mon_name> ] [ <v6in_direction> ] [ <v6in_profile_id> ] [ <l2in_mon_name> ] [ <l2in_direction> ] [ <l2in_profile_id> ] } ] ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

interface

Flow interface information

intf

(Optional) Interface

vlan

Flow vlan information

vlan

(Optional) Vlan number

__readonly__

(Optional)

TABLE_flow_interface

(Optional) flow interface data

intf_name

(Optional) Interface

vlan_id

(Optional) VLAN ID

filter

(Optional) Filter name

v4in_mon_name

(Optional) IPv4 Input monitor name

v4in_direction

(Optional) IPv4 Input direction

v4in_profile_id

(Optional) IPv4 Input profile id

v6in_mon_name

(Optional) IPv6 Input monitor name

v6in_direction

(Optional) IPv6 Input direction

v6in_profile_id

(Optional) IPv6 Input profile id

l2in_mon_name

(Optional) l2 Input monitor name

l2in_direction

(Optional) l2 Input direction

l2in_profile_id

(Optional) l2 Input profile id

Command Mode

  • /exec

show flow monitor

show flow monitor [ name ] [ <monitor> [ cache [ detailed ] ] ] [ __readonly__ [ { TABLE_flow_monitor <monitor> [ <description> ] <use_count> [ <record> ] [ <bucket_id> ] [ <exporter1> ] [ <exporter2> ] [ <src_addr> ] [ <dest_addr> ] [ <direction> ] [ <pkt_count> ] [ <byte_count> ] } ] ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

monitor

Show Monitor Configuration

name

(Optional) Show a specific Flow Monitor

monitor

(Optional) Specify a monitor

cache

(Optional) Flow monitor cache contents

detailed

(Optional) Show the entire cache contents

__readonly__

(Optional)

TABLE_flow_monitor

(Optional)

monitor

(Optional)

use_count

(Optional)

description

(Optional)

record

(Optional)

exporter1

(Optional)

exporter2

(Optional)

bucket_id

(Optional)

src_addr

(Optional)

dest_addr

(Optional)

direction

(Optional)

pkt_count

(Optional)

byte_count

(Optional)

Command Mode

  • /exec

show flow profile

show flow profile [ <profile> ] [ __readonly__ [ { TABLE_flow_profile <name> [ <desc> ] <number-of-users> <export-intvl> <source-port> <packet-id-shift> <burst-intvl-shift> <mtu> [ <guess-threshold-lo> ] [ <guess-threshold-hi> ] [ { TABLE_payload_bin <payload-bin-num> <payload-bin-lo> <payload-bin-hi> } ] [ { TABLE_tcpopthdr_bin <tcpopthdr-bin-num> <tcpopthdr-bin-lo> <tcpopthdr-bin-hi> } ] [ { TABLE_rcvwinsize_bin <rcvwinsize-bin-num> <rcvwinsize-bin-lo> <rcvwinsize-bin-hi> } ] } ] ]

Syntax Description

show

Show running system information

flow

Show Analytics information

profile

Show profile Configuration

profile

(Optional) Specify a profile

__readonly__

(Optional)

TABLE_flow_profile

(Optional) HW flow profile

name

(Optional) HW profile name

desc

(Optional) Description of HW profile

number-of-users

(Optional) No. of users

export-intvl

(Optional) Export Interval

source-port

(Optional) Source Port

packet-id-shift

(Optional) IP Packet ID Shift

burst-intvl-shift

(Optional) Burst Interval Shift

mtu

(Optional) MTU

guess-threshold-lo

(Optional) Sequence Number Guess Threshold Lo

guess-threshold-hi

(Optional) Sequence Number Guess Threshold Hi

TABLE_payload_bin

(Optional) Payload Bin

payload-bin-num

(Optional) Bin Number

payload-bin-lo

(Optional) Bin Lo

payload-bin-hi

(Optional) Bin Hi

TABLE_tcpopthdr_bin

(Optional) TCP Opt Hdr Bin

tcpopthdr-bin-num

(Optional) Bin Number

tcpopthdr-bin-lo

(Optional) Bin Lo

tcpopthdr-bin-hi

(Optional) Bin Hi

TABLE_rcvwinsize_bin

(Optional) Receive Windows Size Bin

rcvwinsize-bin-num

(Optional) Bin Number

rcvwinsize-bin-lo

(Optional) Bin Lo

rcvwinsize-bin-hi

(Optional) Bin Hi

Command Mode

  • /exec

show flow record

show flow record [ name ] [ { <record> } | { netflow-original } | { netflow { protocol-port | layer2-switched { input } | { ipv4 | ipv6 | l2 } { original-input } } } ] [ __readonly__ [ { TABLE_flow_record <record> [ <description> ] <use_count> <template> [ <match_ip_src> ] [ <match_ip_dst> ] [ <match_proto> ] [ <match_tos> ] [ <match_l4_src> ] [ <match_l4_dst> ] [ <match_ingress> ] [ <match_egress> ] [ <match_src_as_peer> ] [ <match_dst_as_peer> ] [ <match_ipv6_src> ] [ <match_ipv6_dst> ] [ <match_ipv6_flow> ] [ <match_ipv6_option> ] [ <match_ipv6_traffic> ] [ <match_l2_src> ] [ <match_l2_dst> ] [ <match_l2_src_vlan> ] [ <match_l2_dst_vlan> ] [ <match_l2_1q> ] [ <match_l2_cos> ] [ <match_l2_etype> ] [ <match_flow_dir_match> ] [ <match_ipv4v6_src> ] [ <match_ipv4v6_dst> ] [ <collect_src_as> ] [ <collect_dst_as> ] [ <collect_src_as_peer> ] [ <collect_dst_as_peer> ] [ <collect_fwd_status> ] [ <collect_ipv4_next_hop> ] [ <collect_ipv4_bgp_next> ] [ <collect_ipv6_next_hop> ] [ <collect_ipv6_bgp_next> ] [ <collect_tcp_flags> ] [ <collect_flow_dir> ] [ <collect_bytes> ] [ <collect_bytes_long> ] [ <collect_packets> ] [ <collect_packets_long> ] [ <collect_time_first> ] [ <collect_time_last> ] [ <collect_ingress_coll> ] [ <collect_egress_coll> ] [ <collect_sampler_id> ] [ <collect_ip_ver> ] [ <collect_packet_disp> ] } ] ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

record

Show Record Configuration

name

(Optional) Show the configuration for a specific Flow Record

record

(Optional) Specify a record

netflow-original

(Optional) Traditional IPv4 input NetFlow with origin ASs

netflow

(Optional) Traditional NetFlow collection schemes

ipv4

(Optional) IPv4 collection schemes

ipv6

(Optional) IPv6 collection schemes

l2

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

layer2-switched

(Optional) Layer2-Switched collection schemes

original-input

(Optional) Input NetFlow

input

(Optional) Input NetFlow

protocol-port

(Optional) Protocol and Ports aggregation scheme

__readonly__

(Optional)

TABLE_flow_record

(Optional) flow record data

record

(Optional)

description

(Optional)

use_count

(Optional)

template

(Optional)

match_ip_src

(Optional)

match_ip_dst

(Optional)

match_proto

(Optional)

match_tos

(Optional)

match_l4_src

(Optional)

match_l4_dst

(Optional)

match_ingress

(Optional)

match_egress

(Optional)

match_src_as_peer

(Optional)

match_dst_as_peer

(Optional)

match_ipv6_src

(Optional)

match_ipv6_dst

(Optional)

match_ipv6_flow

(Optional)

match_ipv6_option

(Optional)

match_ipv6_traffic

(Optional)

match_l2_src

(Optional)

match_l2_dst

(Optional)

match_l2_src_vlan

(Optional)

match_l2_dst_vlan

(Optional)

match_l2_1q

(Optional)

match_l2_cos

(Optional)

match_l2_etype

(Optional)

match_flow_dir_match

(Optional)

match_ipv4v6_src

(Optional)

match_ipv4v6_dst

(Optional)

collect_src_as

(Optional)

collect_dst_as

(Optional)

collect_src_as_peer

(Optional)

collect_dst_as_peer

(Optional)

collect_fwd_status

(Optional)

collect_ipv4_next_hop

(Optional)

collect_ipv4_bgp_next

(Optional)

collect_ipv6_next_hop

(Optional)

collect_ipv6_bgp_next

(Optional)

collect_tcp_flags

(Optional)

collect_flow_dir

(Optional)

collect_bytes

(Optional)

collect_bytes_long

(Optional)

collect_packets

(Optional)

collect_packets_long

(Optional)

collect_time_first

(Optional)

collect_time_last

(Optional)

collect_ingress_coll

(Optional)

collect_egress_coll

(Optional)

collect_sampler_id

(Optional)

collect_ip_ver

(Optional)

collect_packet_disp

(Optional)

Command Mode

  • /exec

show flow rtp

show flow rtp { errors { active | history } | details } [ ipv4 | ipv6 ] [ __readonly__ [ <flow-timeout> ] [ { TABLE_flow_rtp <flow-rtp-index> [ <flow-type> ] [ <source-ip> ] [ <destination-ip> ] [ <bridge-domain-id> ] [ <source-port> ] [ <destination-port> ] [ <protocol> ] [ <packet-count> ] [ <bytes-per-sec> ] [ <bits-per-sec> ] [ <start-time> ] [ <if-name> ] [ <vrf-name> ] [ { TABLE_flow_rtp_errors <loss-start> [ <loss-end> ] [ <packet-loss> ] } ] } ] ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

rtp

Real-time Transport Protocol

errors

Show NetFlow RTP flows error information

active

Show RTP flows with active losses

history

Show RTP flows with loss history

details

Show NetFlow RTP detailed information

ipv4

(Optional) Show ipv4 RTP entries

ipv6

(Optional) Show ipv6 RTP entries

__readonly__

(Optional)

TABLE_flow_rtp

(Optional) The XML flow rtp table

flow-timeout

(Optional) Flow Timeout

flow-rtp-index

(Optional) Flow RTP Index

flow-type

(Optional) Flow type - v4,v6

source-ip

(Optional) Source IP

destination-ip

(Optional) Destination IP

bridge-domain-id

(Optional) Bridge Domain ID

source-port

(Optional) Source Port

destination-port

(Optional) Destination Port

protocol

(Optional) Protocol

packet-count

(Optional) Packet Count

bytes-per-sec

(Optional) Bytes Per Second

bits-per-sec

(Optional) Bits Per Second

start-time

(Optional) Flow Start Time

if-name

(Optional) IF/Vlan

vrf-name

(Optional) VRF

TABLE_flow_rtp_errors

(Optional) The XML flow rtp errors table

loss-start

(Optional) Loss Start Time

loss-end

(Optional) Loss End Time

packet-loss

(Optional) Packet loss

Command Mode

  • /exec

show flow rtp timeout

show flow rtp timeout [ __readonly__ { <flush_cache_to> } ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

rtp

Real-time Transport Protocol

timeout

Show NetFlow RTP flow error monitoring timeout values

__readonly__

(Optional)

flush_cache_to

(Optional)

Command Mode

  • /exec

show flow system

show flow system [ __readonly__ <system_exporter_id> [ <switch_latency> ] [ { TABLE_flow_interface [ <intf_name> ] [ <exporter_id> ] [ <profile_name> ] [ <v4in_mon_name> ] [ <v4in_direction> ] [ <v6in_mon_name> ] [ <v6in_direction> ] [ <filter_name> ] [ <event_name> ] [ <ipv4_hit> ] [ <ipv4_create> ] [ <ipv6_hit> ] [ <ipv6_create> ] [ <ce_hit> ] [ <ce_create> ] [ <packets_seen> ] [ <skip_collect> ] [ <export_count> ] } ] ]

Syntax Description

show

Show running system information

flow

Show Analytics information

system

Show system Configuration

__readonly__

(Optional)

system_exporter_id

(Optional) System Exporter ID

switch_latency

(Optional) System Switch Latency Enabled

TABLE_flow_interface

(Optional) flow interface data

intf_name

(Optional) Interface

exporter_id

(Optional) Exporter ID

profile_name

(Optional) HW Profile Name

v4in_mon_name

(Optional) IPv4 Input monitor name

v4in_direction

(Optional) IPv4 Input direction

v6in_mon_name

(Optional) IPv6 Input monitor name

v6in_direction

(Optional) IPv6 Input direction

filter_name

(Optional) User Filter Name

event_name

(Optional) User Event name

ipv4_hit

(Optional) Number of packets that hit an Ipv4 hash entry

ipv4_create

(Optional) Number of packets that created a new Ipv4 hash entry

ipv6_hit

(Optional) Number of packets that hit an Ipv6 hash entry

ipv6_create

(Optional) Number of packets that created a new Ipv6 hash entry

ce_hit

(Optional) Number of packets that hit an ce hash entry

ce_create

(Optional) Number of packets that created a new ce hash entry

packets_seen

(Optional) Number of packets seen

skip_collect

(Optional) Number of packets that skipped the analytics collect

export_count

(Optional) Number of Analytics packets exported

Command Mode

  • /exec

show flow timeout

show flow timeout [ __readonly__ [ <active_to> ] [ <inactive_to> ] [ <fast_to> ] [ <th_pkts> ] [ <agg_age_to> ] <flush_cache_to> ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

timeout

Show NetFlow flow cache timeout values

__readonly__

(Optional)

active_to

(Optional)

inactive_to

(Optional)

fast_to

(Optional)

th_pkts

(Optional)

agg_age_to

(Optional)

flush_cache_to

(Optional)

Command Mode

  • /exec

show flow tracer

show flow tracer [ __readonly__ [ { TABLE_flow_tracer <flow-tracer-index> [ <source-ip> ] [ <destination-ip> ] [ <bridge-domain-id> ] [ <source-port> ] [ <destination-port> ] [ <protocol> ] [ <packet-count> ] [ <if-name> ] [ <fwd-drop> ] [ <rpf-fail> ] [ <policing-drop> ] [ <ids-drop> ] [ <policy-drop> ] [ <buffer-drop> ] } ] ]

Syntax Description

show

Show running system information

flow

Show NetFlow information

tracer

Show packet tracer information

__readonly__

(Optional)

TABLE_flow_tracer

(Optional)

flow-tracer-index

(Optional) Flow Index

source-ip

(Optional) Source IP

destination-ip

(Optional) Destination IP

bridge-domain-id

(Optional) Bridge Domain ID

source-port

(Optional) Source Port

destination-port

(Optional) Destination Port

protocol

(Optional) Protocol

packet-count

(Optional) Packet Count

if-name

(Optional) Ingress Interface

fwd-drop

(Optional) Fowarding Drops

rpf-fail

(Optional) RPF Port Sec Failures

policing-drop

(Optional) Policing Drops

ids-drop

(Optional) Ids Drops

policy-drop

(Optional) ACL Drops

buffer-drop

(Optional) Buffer Drops

Command Mode

  • /exec

show flow vrf

show flow vrf [ <vrf_name> ] [ __readonly__ [ { TABLE_flow_vrf [ <vrf_name> ] [ <v4in_mon_name> ] [ <v4in_direction> ] [ <v6in_mon_name> ] [ <v6in_direction> ] [ <filter_name> ] } ] ]

Syntax Description

show

Show running system information

flow

Show Analytics information

vrf

Show VRF Configuration

vrf_name

(Optional) Specify a vrf

__readonly__

(Optional)

TABLE_flow_vrf

(Optional) flow vrf data

vrf_name

(Optional) VRF name

v4in_mon_name

(Optional) IPv4 Input monitor name

v4in_direction

(Optional) IPv4 Input direction

v6in_mon_name

(Optional) IPv6 Input monitor name

v6in_direction

(Optional) IPv6 Input direction

filter_name

(Optional) User Filter Name

Command Mode

  • /exec

show forwarding

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } | table <table_id> ] [ ipv4 ] [ route | rnhdb ] [ recursive ] [ summary | [ [ detail | platform | partial | ipsg ] [ max-display-count <display_count> ] ] | [ <prefix> [ longer-prefixes ] [ detail | platform ] | <address> [ detail | platform ] |

Syntax Description

show

forwarding

display fib information

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

table

(Optional) display info per vpn-id

table_id

(Optional) table id in hex

ipv4

(Optional) ipv4

route

(Optional) display IP routing table

ipsg

(Optional) display IPv4 IPSG routes

rnhdb

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

recursive

(Optional) display routes with recursive next hops

partial

(Optional) display routes with partial ECMPs

summary

(Optional) display route counts

prefix

(Optional) display single exact match route

longer-prefixes

(Optional) display longer prefixes

address

(Optional) display single longest match route

detail

(Optional) show detailed information about the routes

platform

(Optional) one command to show pi and pd info together

max-display-count

(Optional) displays max # of routes

display_count

(Optional) count

Command Mode

  • /exec

show forwarding adjacency

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } ] [ ipv4 ] adjacency [ mpls ] [ lisp ] [ nve ] [ <aif> ] [ <anh> ] [ detail | stats | platform ] [ module <module> ] [ __readonly__ [ <adj-count> ] [ TABLE_adj { [ <fec> ] [ <nexthop> ] [ <intf> ] [ <rewinfo> ] [ <interface> ] [ <bgp_rnh> ] [ <bgp_orig_as> ] [ <bgp_peer_as> ] [ <pkts> ] [ <bytes> ] [ <exp> ] [ <src_addr> ] [ <dest_addr> ] [ <lisp_flags> ] [ <lisp_inst_id> ] [ <pltfm_key> ] [ <hh> ] [ <refcount> ] } ] [ TABLE_ip_adjacency { [ <nh> ] [ <rwinfo> ] [ <intf> ] [ <intf_idx> ] [ <hhandle> ] [ <refcnt> ] [ <flags> ] [ <holder> ] [ <pbr_cnt> ] [ <wccp_cnt> ] [ <rewrite-p> ] [ TABLE_index { [ <hw_adj> ] [ <cmn-idx> ] [ <lif> ] [ <buf-idx> ] } ] } ] ]

Syntax Description

show

forwarding

display fib information

ipv4

(Optional) ipv4

adjacency

display adjacency information

platform

(Optional) one command to show pi and pd info together

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

mpls

(Optional) mpls adjacency information

lisp

(Optional) LISP adjacency information

nve

(Optional) VxLAN tunnel adjacency information

aif

(Optional) adjacency output interface

anh

(Optional) adjacency next hop

detail

(Optional) detail

stats

(Optional) adjacency statistics

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

adj-count

(Optional) total adj count

TABLE_adj

(Optional) Table Adjacency

fec

(Optional) FEC info

nexthop

(Optional) next hop address

intf

(Optional) output interface

rewinfo

(Optional) rewrite information

interface

(Optional) output interface

bgp_rnh

(Optional) next hop address

bgp_orig_as

(Optional) bgp orig as

bgp_peer_as

(Optional) bgp peer as

exp

(Optional) exp mapping

pkts

(Optional) packet stats

bytes

(Optional) bytes stats

src_addr

(Optional) src address

dest_addr

(Optional) dest address

lisp_flags

(Optional) lisp flags

lisp_inst_id

(Optional) lisp instance id

pltfm_key

(Optional) platform key

hh

(Optional) Hardware Handle

refcount

(Optional) reference count

TABLE_ip_adjacency

(Optional) Table ip adjacency

nh

(Optional) next hop address

rwinfo

(Optional) rewrite information

intf

(Optional) output interface

intf_idx

(Optional) Interface index

hhandle

(Optional) Hw Handle

refcnt

(Optional) reference count

flags

(Optional) Adjacency flags

holder

(Optional) Holder bitmap

pbr_cnt

(Optional) PBR count

wccp_cnt

(Optional) WCCP count

rewrite-p

(Optional) Rewrite pointer

TABLE_index

(Optional) HW index table

hw_adj

(Optional) v4 adj hw index

cmn-idx

(Optional) CMN Index

lif

(Optional) LIF

buf-idx

(Optional) Buffer index

Command Mode

  • /exec

show forwarding consistency-fretta l2

show forwarding consistency-fretta l2 <module>

Syntax Description

show

Show running system information

forwarding

Forwarding information

consistency-fretta

consistency

l2

Verify l2 mac programming in the hardware

module

Enter module number

Command Mode

  • /exec

show forwarding distribution clients

show forwarding distribution clients [ __readonly__ <id><pid><name><shms><shme><shmn> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

fib distribution info

clients

unicast client information

__readonly__

(Optional)

Command Mode

  • /exec

show forwarding distribution evpn storm-control

show forwarding distribution evpn storm-control [ __readonly__ <header> [ TABLE_storm_control_level <type> <status> <level> ] [ TABLE_interface_bandwidth <interface> <type> <bandwidth> ] [ TABLE_total_bandwidth <type> <bandwidth> ] ]

Syntax Description

show

Show running system information

forwarding

forwarding information

distribution

fib distribution info

evpn

evpn distribution info

storm-control

storm-control information

__readonly__

(Optional)

header

(Optional) Header

TABLE_storm_control_level

(Optional) Table storm control level

type

(Optional) Traffic type

status

(Optional) Status

level

(Optional) Level

TABLE_interface_bandwidth

(Optional) Table interface bandwidth

interface

(Optional) Interface

type

(Optional) Type

bandwidth

(Optional) Bandwidth

TABLE_total_bandwidth

(Optional) Table total bandwidth

type

(Optional) Type

bandwidth

(Optional) Bandwidth

Command Mode

  • /exec

show forwarding distribution fib-state

show forwarding distribution fib-state [ __readonly__ <slot> <state><ttc><tprc><tv4ac><tv6ac> { TABLE_fib_state <tid><tafi><prc><pc><tname> } ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

fib distribution info

fib-state

unicast fib state info

__readonly__

(Optional)

slot

(Optional) slot number

TABLE_fib_state

(Optional) fib-state table

Command Mode

  • /exec

show forwarding distribution ip igmp snooping

show forwarding distribution ip igmp snooping [ vlan <vlan-id> [ group [ <grpaddr> | <mac-grpaddr> ] [ source <srcaddr> ] ] ] [ detail ] [ __readonly__ <refcount> <oiflist_id> <last_oiflist_id> <ftag-id> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

ip

IPV4 information

igmp

MFDM IGMP information

snooping

L2 mcast snooping related information

vlan

(Optional) Info specific to a vlan

vlan-id

(Optional) Vlan id value

group

(Optional) Group specific information

grpaddr

(Optional) Group address

mac-grpaddr

(Optional) Group MAC address

source

(Optional) (G,S) specific information

srcaddr

(Optional) Source address

detail

(Optional) Detailed display

__readonly__

(Optional)

refcount

(Optional) Reference Count

oiflist_id

(Optional) OIF list Identifier

last_oiflist_id

(Optional) Last OIF list Identifier

ftag-id

(Optional) ftag Id

Command Mode

  • /exec

show forwarding distribution ipv6 multicast route

show forwarding distribution ipv6 multicast route [ table <table_id> | vrf { <vrf-name> | all } ] [ [ group { <group> } [ source { <source> } ] ] | summary ] [ __readonly__ TABLE_vrf [ <vrf-name> ] [ <table-name> ] [ <table-id> ] [ <total-num-groups> ] [ TABLE_route_summary [ <vrf-name> ] [ <total-num-routes> ] [ <num-star-g-route> ] [ <num-sg-route> ] [ <num-star-g-prfx> ] [ <num-group-count> ] ] [ TABLE_one_route [ <source-addrs> ] [ <source-len> ] [ <group-addrs> ] [ <group-len> ] [ <df-ordinal> ] [ <rpf-intf> ] [ <flags> ] [ <upstream-addrs> ] [ <stats-pkts> ] [ <stats-bytes> ] [ <oif-count> ] [ <oiflist-index> ] [ TABLE_oif [ <oif-name> ] [ <mti-src-intf> ] [ <mti-grp-ip> ] [ <mti-src-ip> ] ] ] ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

display fib distribution information

ipv6

IPV6 related information

multicast

display IPv6 multicast information

route

display routing table

vrf

(Optional) display routes for a specific VRF

vrf-name

(Optional) VRF name

all

(Optional) Display information for all VRFs

table

(Optional) table

table_id

(Optional) table number

group

(Optional) Multicast IPv6 Group Address

source

(Optional) Multicast IPv6 Source Address

summary

(Optional) display route counts

__readonly__

(Optional)

TABLE_vrf

(Optional)

vrf-name

(Optional)

table-name

(Optional)

table-id

(Optional)

total-num-groups

(Optional)

TABLE_route_summary

(Optional)

total-num-routes

(Optional)

num-star-g-route

(Optional)

num-sg-route

(Optional)

num-star-g-prfx

(Optional)

num-group-count

(Optional)

TABLE_one_route

(Optional)

source-addrs

(Optional)

source-len

(Optional)

group-addrs

(Optional)

group-len

(Optional)

df-ordinal

(Optional)

rpf-intf

(Optional)

flags

(Optional)

stats-pkts

(Optional)

stats-bytes

(Optional)

oif-count

(Optional)

oiflist-index

(Optional)

TABLE_oif

(Optional)

oif-name

(Optional)

mti-src-intf

(Optional)

mti-grp-ip

(Optional)

mti-src-ip

(Optional)

Command Mode

  • /exec

show forwarding distribution l2 multicast

show forwarding distribution l2 multicast [ ip-based | mac-based ] [ [ vni <vni-id> ] | [ vlan <vlan-id> [ { group { <grpaddr> | <v6grpaddr> } [ source { <srcaddr> | <v6srcaddr> } ] } | destination-mac <dmac> ] ] ] [ summary ] [ __readonly__ [ TABLE_sum [ <mode> ] [ <num_vlan> ] [ <num_starg> ] [ <num_sg> ] [ <num_aggstarg> ] [ TABLE_sum_info [ <ftag_id> ] [ <vlan_id> ] [ <routable_flag> ] [ <v6_routable_flag> ] [ <num_starg> ] [ <num_sg> ] [ <num_aggstarg> ] [ <total_route> ] ] ] [ TABLE_route [ <vlan> ] [ <grp_str> ] [ <v6grp_str> ] [ <src_str> ] [ <v6src_str> ] [ <grp_mac> ] [ <src_mac> ] [ TABLE_oif [ <oiflist_id> ] [ <refcount> ] [ <l3_usage> ] [ <plt_index> ] [ <num_oif> ] [ <oif_name> ] [ <flags> ] [ <dvif> ] ] ] ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

l2

L2 information

multicast

L2 multicast information

ip-based

(Optional) IPv4 based

mac-based

(Optional) MAC based

vlan

(Optional) Info specific to a vlan

vlan-id

(Optional) Vlan id value

vni

(Optional) Info specific to a vni

vni-id

(Optional) Vni id value

group

(Optional) Group specific information

grpaddr

(Optional) Group address

source

(Optional) (G,S) specific information

srcaddr

(Optional) Source address

destination-mac

(Optional) Destination MAC specific information

dmac

(Optional) Destination MAC address

summary

(Optional) display route counts

__readonly__

(Optional)

TABLE_sum

(Optional)

mode

(Optional) Mode

num_vlan

(Optional) Num of VLAN

num_starg

(Optional) Num of Starg routes

num_sg

(Optional) Num of SG routes

num_aggstarg

(Optional) Num of Aggregated Starg routes

TABLE_sum_info

(Optional)

vlan_id

(Optional) vlan id

ftag_id

(Optional) ftag id

routable_flag

(Optional) Routable flag

v6_routable_flag

(Optional) Routable flag

num_starg

(Optional) Num of starg routes

num_sg

(Optional) Num of sg routes

num_aggstarg

(Optional) Num of Aggregated Starg routes

total_route

(Optional) Total Routes

TABLE_route

(Optional)

vlan

(Optional) vlan

grp_str

(Optional) Group Address

v6grp_str

(Optional) v6 Group address

src_str

(Optional) Source Address

v6src_str

(Optional) v6 Group address

grp_mac

(Optional) Group Mac

src_mac

(Optional) Source Mac

TABLE_oif

(Optional)

oiflist_id

(Optional) oiflist index

refcount

(Optional) reference count

l3_usage

(Optional) l3 usage

plt_index

(Optional) platform index

num_oif

(Optional) Num of outging interface

oif_name

(Optional) Oif details

flags

(Optional)

dvif

(Optional)

Command Mode

  • /exec

show forwarding distribution lisp counters

show forwarding distribution lisp counters [ __readonly__ <count> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

fib distribution information

lisp

for lisp application

counters

counters

__readonly__

(Optional)

count

(Optional) count

Command Mode

  • /exec

show forwarding distribution lisp vrf enabled

show forwarding distribution lisp vrf enabled [ __readonly__ { TABLE_lisp_vrf_enabled <vrf> <lisp_enabled> <req_id> <operation> } ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

fib distribution information

lisp

for lisp application

vrf

vrf

enabled

enabled

__readonly__

(Optional)

TABLE_lisp_vrf_enabled

(Optional)

vrf

(Optional) vrf key

lisp_enabled

(Optional) lisp enabled status

req_id

(Optional) req id

operation

(Optional) operation

Command Mode

  • /exec

show forwarding distribution multicast

show forwarding distribution multicast [ messages ] [ __readonly__ <num_accepting_routes> <slot> <fibstate> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast FIB distribution information

messages

(Optional) Outstanding Message Information

__readonly__

(Optional)

num_accepting_routes

(Optional) Number of fibs accepting routes

slot

(Optional) Slot

fibstate

(Optional) IP Multicast FIB process state

Command Mode

  • /exec

show forwarding distribution multicast client-ack-db

show forwarding distribution multicast client-ack-db [ __readonly__ <xid> <num_recepients> <num_responses> ]

Syntax Description

show

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast

client-ack-db

Displays the client ack db

__readonly__

(Optional)

xid

(Optional) XID

num_recepients

(Optional) Number of recepients

num_responses

(Optional) Number of responses

Command Mode

  • /exec

show forwarding distribution multicast client

show forwarding distribution multicast client [ __readonly__ <num-clients> <client-name> <client-id> <shmem-name> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast information

client

Show multicast distribution client information

__readonly__

(Optional)

num-clients

(Optional) Number of Clients registered

client-name

(Optional) Client Name

client-id

(Optional) Client-id

shmem-name

(Optional) Shared Memory Segment Name

Command Mode

  • /exec

show forwarding distribution multicast download

show forwarding distribution multicast download [ __readonly__ [ TABLE_MFDM_DOWNLOAD_INFO <db_type> [ TABLE_MFDM_PENDING_INFO [ <table_id> ] ] ] ]

Syntax Description

show

forwarding

forwarding information

distribution

FIB distribution information

multicast

Multicast FIB distribution information

download

show download queues

__readonly__

(Optional)

TABLE_MFDM_DOWNLOAD_INFO

(Optional) MFDM download info

db_type

(Optional) Database type

TABLE_MFDM_PENDING_INFO

(Optional) Routes Pending info

table_id

(Optional) Table ID

Command Mode

  • /exec

show forwarding distribution multicast mfib

show forwarding distribution multicast { mfib-txlist [ vrf <vrf-name> ] | mfib-buffers } [ __readonly__ <no-free-buffers> <no-used-buffers> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast information

mfib-txlist

Show MFIB transmission-list information

vrf

(Optional) Specify VRF

vrf-name

(Optional) Specify VRF name

mfib-buffers

Show MFIB route buffer information

__readonly__

(Optional)

no-free-buffers

(Optional) Number of Free txlist MFIB buffers

no-used-buffers

(Optional) Number of Used txlist MFIB buffers

Command Mode

  • /exec

show forwarding distribution multicast outgoing-interface-list L2_PRIME

show forwarding distribution multicast outgoing-interface-list L2_PRIME [ __readonly__ <index> <dvif> <platform_index> <ref_count> <l2-oifs> <port_set> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast FIB distribution information

outgoing-interface-list

Outgoing interface list

L2_PRIME

Layer 2 oiflist

index

(Optional) Outgoing Interface List index

__readonly__

(Optional)

dvif

(Optional) Destination VIF

platform_index

(Optional) Platform index

ref_count

(Optional) Reference count

l2-oifs

(Optional) L2 oifs

port_set

(Optional) Port set

Command Mode

  • /exec

show forwarding distribution multicast resp-ack-timer-msgs

show forwarding distribution multicast resp-ack-timer-msgs

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast information

resp-ack-timer-msgs

show response ack timers for MFDM

Command Mode

  • /exec

show forwarding distribution multicast route

show forwarding distribution [ ip ] multicast route [ table <id> | vrf { <vrf_name> | <vrf-known-name> | all } ] [ [ group { <gaddr> [ <mask> ] | <gprefix> } [ source { <saddr> [ <smask> ] | <sprefix> } ] ] | summary ] [ __readonly__ TABLE_vrf [ <vrf-name> ] [ <table-name> ] [ <table-id> ] [ <table-wildcard> ] [ <total-num-groups> ] [ TABLE_route_summary [ <vrf-name> ] [ <total-num-routes> ] [ <num-star-g-route> ] [ <num-sg-route> ] [ <num-star-g-prfx> ] [ <num-group-count> ] ] [ TABLE_one_route [ <source-addrs> ] [ <source-len> ] [ <group-addrs> ] [ <group-len> ] [ <df-ordinal> ] [ <rpf-intf> ] [ <flags> ] [ <upstream-addrs> ] [ <stats-state> ] [ <stats-pkts> ] [ <stats-bytes> ] [ <oif-count> ] [ <oiflist-index> ] [ TABLE_oif [ <oif-name> ] [ <mti-src-intf> ] [ <mti-grp-ip> ] [ <mti-src-ip> ] [ <next-hop> ] ] ] ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

ip

(Optional) IPV4 information

multicast

Multicast information

route

Multicast route related information

vrf

(Optional) Specify VRF

vrf_name

(Optional) Specify VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display information for all VRFs

table

(Optional) Specify Multicast Routing Table

id

(Optional) Multicast Routing Table Identifier

group

(Optional) IPv4 Multicast Group specific

gaddr

(Optional) IPv4 Multicast Group Address

mask

(Optional) mask for group ip address

gprefix

(Optional) IPv4 Multicast Group Prefix

source

(Optional) IPv4 Multicast Source specific

saddr

(Optional) IPv4 Source Address

smask

(Optional) mask for group ip address

sprefix

(Optional) IPv4 Multicast Source Prefix

summary

(Optional) display route counts

__readonly__

(Optional)

TABLE_vrf

(Optional)

vrf-name

(Optional)

table-name

(Optional)

table-id

(Optional)

table-wildcard

(Optional)

total-num-groups

(Optional)

TABLE_route_summary

(Optional)

total-num-routes

(Optional)

num-star-g-route

(Optional)

num-sg-route

(Optional)

num-star-g-prfx

(Optional)

num-group-count

(Optional)

TABLE_one_route

(Optional)

source-addrs

(Optional)

source-len

(Optional)

group-addrs

(Optional)

group-len

(Optional)

df-ordinal

(Optional)

rpf-intf

(Optional)

upstream-addrs

(Optional)

flags

(Optional)

stats-state

(Optional)

stats-pkts

(Optional)

stats-bytes

(Optional)

oif-count

(Optional)

oiflist-index

(Optional)

TABLE_oif

(Optional)

oif-name

(Optional)

mti-src-intf

(Optional)

mti-grp-ip

(Optional)

mti-src-ip

(Optional)

next-hop

(Optional)

Command Mode

  • /exec

show forwarding distribution multicast route sr um-nat

show forwarding distribution multicast route sr um-nat [ __readonly__ TABLE_one_route <pre-translated-source-addrs><pre-translated-dest-addrs> <post-translated-source-addrs><post-translated-dest-addrs> <post-translated-source-udp-port><post-translated-dest-udp-port> <mti-src-intf><vrf-name> ]

Syntax Description

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast information

route

Multicast route related information

sr

sr related information

um-nat

UM NAT route translation information

__readonly__

(Optional)

TABLE_one_route

(Optional)

Command Mode

  • /exec

show forwarding distribution multicast sr hash-db

show forwarding distribution multicast sr hash-db

Syntax Description

show

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast

sr

Service reflect rules

hash-db

Hash database

Command Mode

  • /exec

show forwarding distribution multicast vxlan dsg-db

show forwarding distribution multicast vxlan dsg-db

Syntax Description

show

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast

vxlan

vxlan

dsg-db

delivery group/source db

Command Mode

  • /exec

show forwarding distribution multicast vxlan vlan-db

show forwarding distribution multicast vxlan vlan-db

Syntax Description

show

show

forwarding

Display Forwarding Information

distribution

FIB distribution information

multicast

Multicast

vxlan

vxlan

vlan-db

Vlan database

Command Mode

  • /exec

show forwarding distribution nve overlay-vlan

show forwarding distribution nve overlay-vlan [ __readonly__ TABLE_overlay_vlan_peer_id <Vlan> <SVP> <install> <Origin> <VFP-region> <peercount> <peer_id> + ]

Syntax Description

show

Show running system information

forwarding

forwarding information

distribution

fib distribution info

nve

nve distribution info

overlay-vlan

overlay-vlan adjacency info

__readonly__

(Optional)

TABLE_overlay_vlan_peer_id

(Optional) overlay vlan peer id table

Vlan

(Optional) VLAN

SVP

(Optional) SVP

install

(Optional) install

Origin

(Optional) Origin

VFP-region

(Optional) VFP-region

peercount

(Optional) Total count of Peers

peer_id

(Optional) Peer-ID

Command Mode

  • /exec

show forwarding distribution peer-id

show forwarding distribution peer-id [ vpls | otv ] [ __readonly__ <header> TABLE_peer_id <app> <vlan> <id> <peer_id> ]

Syntax Description

show

Show running system information

forwarding

forwarding information

distribution

fib distribution info

peer-id

HW Peer-id allocation info

vpls

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

otv

(Optional) OTV

__readonly__

(Optional)

header

(Optional) Header

TABLE_peer_id

(Optional) Peer ID table

app

(Optional) OTV/VPLS

vlan

(Optional) VLAN

id

(Optional) ID

peer_id

(Optional) Peer-ID

Command Mode

  • /exec

show forwarding distribution srv6 local-sid bd-mapping

show forwarding distribution srv6 local-sid bd-mapping [ __readonly__ { local_sid_bd_map <sid_bd_map> } [ { TABLE_local_sid <local_sid> <Table_id> <func_type> <bd> <locator> <function> <args> } ] ]

Syntax Description

show

Show running system information

forwarding

forwarding information

distribution

fib distribution info

srv6

Srv6 related

local-sid

Local SID

bd-mapping

Local Sid to BD mappings

__readonly__

(Optional)

local_sid_bd_map

(Optional) Local-sid to BD mapping

sid_bd_map

(Optional) Local-sid to BD mappingi number

TABLE_local_sid

(Optional) Table with local SID's

local_sid

(Optional) V6 prefix associated with local-sid

Table_id

(Optional) Table ID

func_type

(Optional) Function behavior type

bd

(Optional) Bridge domain

locator

(Optional) Locator V6 address

function

(Optional) function

args

(Optional) args

Command Mode

  • /exec

show forwarding distribution trace

show forwarding distribution trace

Syntax Description

show

forwarding

Display Forwarding Information

distribution

fib distribution info

trace

unicast trace information

Command Mode

  • /exec

show forwarding ecmp

show forwarding ecmp [ { [ vrf { <vrf-name> | <vrf-known-name> } ] lisp } ] [ platform ] [ module <module> ] [ partial ] [ __readonly__ [ <header> <ecmp_hash> <intf> <nh> <v6nh> <hw_index> <num_mpls> <holder> <refcount> <num_paths> <sw_ptr> <ecmp_partial> ] [ TABLE_ecmp { [ <hash> ] [ <num_paths> ] [ <hwindex> ] [ <ecmppartial> ] [ TABLE_index { [ <ecmp_idx> ] [ <cmn_idx> ] } ] [ <refcnt> ] [ <ecmp_holder> ] } [ TABLE_adjacency { [ <intf> ] [ <nh> ] [ <v6nh> ] [ <hw_adj_idx> ] [ <hw_cmn_idx> ] [ <lif> ] [ <hw_nve_adj_idx> ] [ <hw_nve_cmn_idx> ] [ <nve_lif> ] } ] [ <vobj_count> ] [ <vxlan_vobj_count> ] [ <vxlan> ] [ <vobj_list_header> ] [ <vobj-id> ] ] ]

Syntax Description

show

forwarding

Display fib information

ecmp

Show information about ECMPs

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

lisp

(Optional) Show information about LISP ECMPs

platform

(Optional) one command to show pi and pd info together

module

(Optional) slot

module

(Optional) slot number

partial

(Optional) Show partially installed ECMPs

__readonly__

(Optional)

header

(Optional) o/p header

ecmp_hash

(Optional) ecmp hash

intf

(Optional) interface

nh

(Optional) next hop

v6nh

(Optional) V6 next hop

hw_index

(Optional) Hw index

num_mpls

(Optional) No of MPLS ecmp

holder

(Optional) holder bitmap

refcount

(Optional) refcount

sw_ptr

(Optional) Software pointer

num_paths

(Optional) No of paths

ecmp_partial

(Optional) partial ecmp

TABLE_ecmp

(Optional) ecmp table

hash

(Optional) ecmp hash

num_paths

(Optional) No of paths

hwindex

(Optional) Hw index

ecmppartial

(Optional) partial ecmp

TABLE_index

(Optional) index table

ecmp_idx

(Optional) hw ecmp index

cmn_idx

(Optional) cmn index

refcnt

(Optional) refcount

ecmp_holder

(Optional) holder bitmap

TABLE_adjacency

(Optional) adjacency table

intf

(Optional) interface

nh

(Optional) next hop

v6nh

(Optional) v6 next hop

hw_adj_idx

(Optional) hw adj index

hw_cmn_idx

(Optional) hw cmn index

lif

(Optional) lif

hw_nve_adj_idx

(Optional) nve adj index

hw_nve_cmn_idx

(Optional) nve cmn index

nve_lif

(Optional) nve lif

vobj_count

(Optional) vobj count

vxlan_vobj_count

(Optional) vxlan vobj count

vxlan

(Optional) vxlan

vobj_list_header

(Optional) vobj list header

vobj-id

(Optional) vobj id

Command Mode

  • /exec

show forwarding ecmp recursive

show forwarding ecmp recursive [ platform ] [ srv6 ] [ max-display-count <display_count> ] [ module <module> ] [ partial ] [ __readonly__ [ TABLE_vobj { [ <header_vobj> ] [ <header_ecmp> ] } [ TABLE_vobj_idx { [ <hw_vobj_index> ] [ <cmn_index> ] } ] [ <num_pfxs> ] [ <ecmp_partial> ] [ <activepath_hdr> ] [ <ecmp_hw_prog_fail> ] [ TABLE_active { [ TABLE_activepath { [ <ap_nh> ] [ <ap_v6nh> ] [ <ap_rnh_len> ] [ <ap_nh_vpn_label> ] [ <ap_rnh_table_id> ] [ <ap_nh_weight> ] } ] } ] [ <backuppath_hdr> ] [ TABLE_backuppath { [ <bp_nh> ] [ <bp_v6nh> ] [ <bp_nh_vpn_label> ] [ <bp_rnh_table_id> ] [ <bp_nh_weight> ] } ] [ <cnh_hdr> ] [ TABLE_cnh { [ <nh> ] [ <v6nh> ] [ <intf> ] [ TABLE_cnh_adj { [ <hw_adj> ] [ <hw_cmn_index> ] [ <lif> ] } ] } ] [ <hw_inst_n> ] [ <ls_count_n> ] [ <hw_inst_o> ] [ <ls_count_o> ] [ <fec_type> ] [ <header_fec_ecmp> ] [ <hw_vobj_fec_idx> ] [ <cmn_idx> ] [ <vobj_hw_inst_n> ] [ <vobj_ls_count_n> ] [ <vobj_hw_inst_o> ] [ <vobj_ls_count_o> ] [ <vobj_refcount> ] [ <vobj_function> ] [ TABLE_vobj_ecmp { [ <ec_hash> ] [ <ec_num_paths> ] [ <ec_hwindex> ] [ <ec_ecmppartial> ] [ <ec_refcnt> ] [ <ec_ecmp_holder> ] } [ TABLE_adjacency_ec { [ <ec_intf> ] [ <ec_nh> ] [ <ec_v6nh> ] [ <ec_hw_adj_idx> ] [ <ec_hw_cmn_idx> ] [ <ec_lif> ] [ <ec_hw_nve_adj_idx> ] [ <ec_hw_nve_cmn_idx> ] [ <ec_nve_lif> ] } ] [ <ec_vobj_count> ] [ <ec_vxlan_vobj_count> ] [ <ec_vxlan> ] [ <ec_vobj_list_header> ] ] ] [ <header> <num_pfxs> <rnh_table_id> <nh> <rnh_len> <v6nh> <hw_instance> <nh_vpn_label> <nh_weight> <cnh_intf> <ecmp_partial> ] [ TABLE_ecmp { [ <hash> ] [ <num_paths> ] [ <hwindex> ] [ <ecmppartial> ] [ TABLE_index { [ <ecmp_idx> ] [ <cmn_idx> ] } ] [ <refcnt> ] [ <ecmp_holder> ] } [ TABLE_adjacency { [ <intf> ] [ <nh> ] [ <v6nh> ] [ <hw_adj_idx> ] [ <hw_cmn_idx> ] [ <lif> ] [ <hw_nve_adj_idx> ] [ <hw_nve_cmn_idx> ] [ <nve_lif> ] } ] [ <vobj_count> ] [ <vxlan_vobj_count> ] [ <vxlan> ] [ <vobj_list_header> ] [ TABLE_vobj_id { [ <vobj-id> ] } ] [ <vobj_function> ] ] ]

Syntax Description

show

forwarding

Display fib information

ecmp

Show information about ECMPs

recursive

Show information about recursive ECMPs

platform

(Optional) one command to show pi and pd info together

srv6

(Optional) Show information about SRV6 encap

module

(Optional) slot

partial

(Optional) Show partially installed ECMPs

module

(Optional) slot number

max-display-count

(Optional) displays max # of routes

display_count

(Optional) count

__readonly__

(Optional)

TABLE_vobj

(Optional) Table vobj

header_vobj

(Optional) vobj o/p header

header_ecmp

(Optional) ecmp o/p header

TABLE_vobj_idx

(Optional) Table vobj index

hw_vobj_index

(Optional) HW VOBJ Index

cmn_index

(Optional) cmn index

num_pfxs

(Optional) Number of prefixes using this virtual object

ecmp_partial

(Optional) partial ecmp

ecmp_hw_prog_fail

(Optional) Ecmp Hardware Program failure

activepath_hdr

(Optional) o/p header

TABLE_active

(Optional) table active

TABLE_activepath

(Optional) table active path

ap_nh

(Optional) Next hop info

ap_v6nh

(Optional) v6 Next hop info

ap_rnh_len

(Optional) Next hop mask length

ap_nh_vpn_label

(Optional) NH VPN label

ap_rnh_table_id

(Optional) The table id where the RNHs are present

ap_nh_weight

(Optional) weighted ecmp info

backuppath_hdr

(Optional) o/p header

TABLE_backuppath

(Optional) backup path table

bp_nh

(Optional) Next hop info

bp_v6nh

(Optional) v6 Next hop info

bp_nh_vpn_label

(Optional) NH VPN label

bp_rnh_table_id

(Optional) The table id where the RNHs are present

bp_nh_weight

(Optional) weighted ecmp info

cnh_hdr

(Optional) o/p header

TABLE_cnh

(Optional) cnh table

nh

(Optional) Next hop info

v6nh

(Optional) v6 Next hop info

intf

(Optional) cnh output interface

TABLE_cnh_adj

(Optional) Table cnh adjacency

hw_adj

(Optional) cnh hw adjacency

hw_cmn_index

(Optional) cnh hw cmn idx

lif

(Optional) lif

hw_inst_n

(Optional) Hardware instance info new

ls_count_n

(Optional) ls count new

hw_inst_o

(Optional) Hardware instance info old

ls_count_o

(Optional) ls count old

fec_type

(Optional) fec type

header_fec_ecmp

(Optional) o/p header

hw_vobj_fec_idx

(Optional) hw fec idx

cmn_idx

(Optional) cmn idx

vobj_hw_inst_n

(Optional) vobj hw instance

vobj_ls_count_n

(Optional) ls count new

vobj_hw_inst_o

(Optional) hw instnace info old

vobj_ls_count_o

(Optional) ls count old

vobj_refcount

(Optional) vobj refcount

vobj_function

(Optional) vobj function

TABLE_vobj_ecmp

(Optional) ecmp table

ec_hash

(Optional) ecmp hash

ec_num_paths

(Optional) No of paths

ec_hwindex

(Optional) Hw index

ec_ecmppartial

(Optional) partial ecmp

ec_refcnt

(Optional) refcount

ec_ecmp_holder

(Optional) holder bitmap

TABLE_adjacency_ec

(Optional) adjacency table

ec_intf

(Optional) interface

ec_nh

(Optional) next hop

ec_v6nh

(Optional) v6 next hop

ec_hw_adj_idx

(Optional) hw adj index

ec_hw_cmn_idx

(Optional) hw cmn index

ec_lif

(Optional) lif

ec_hw_nve_adj_idx

(Optional) nve adj index

ec_hw_nve_cmn_idx

(Optional) nve cmn index

ec_nve_lif

(Optional) nve lif

ec_vobj_count

(Optional) vobj count

ec_vxlan_vobj_count

(Optional) vxlan vobj count

ec_vxlan

(Optional) vxlan

ec_vobj_list_header

(Optional) vobj list header

vobj_function

(Optional) vobj function

header

(Optional) o/p header

num_pfxs

(Optional) Number of prefixes using this virtual object

rnh_table_id

(Optional) The table id where the RNHs are present

nh

(Optional) Next hop info

rnh_len

(Optional) Next hop mask length

v6nh

(Optional) V6 Next hop info

hw_instance

(Optional) Hardware instance info

nh_vpn_label

(Optional) NH VPN label

nh_weight

(Optional) weighted ecmp info

cnh_intf

(Optional) cnh output interface

ecmp_partial

(Optional) partial ecmp

TABLE_ecmp

(Optional) ecmp table

hash

(Optional) ecmp hash

num_paths

(Optional) No of paths

hwindex

(Optional) Hw index

ecmppartial

(Optional) partial ecmp

TABLE_index

(Optional) index table

ecmp_idx

(Optional) hw ecmp index

cmn_idx

(Optional) cmn index

refcnt

(Optional) refcount

ecmp_holder

(Optional) holder bitmap

TABLE_adjacency

(Optional) adjacency table

intf

(Optional) interface

nh

(Optional) next hop

v6nh

(Optional) v6 next hop

hw_adj_idx

(Optional) hw adj index

hw_cmn_idx

(Optional) hw cmn index

lif

(Optional) lif

hw_nve_adj_idx

(Optional) nve adj index

hw_nve_cmn_idx

(Optional) nve cmn index

nve_lif

(Optional) nve lif

vobj_count

(Optional) vobj count

vxlan_vobj_count

(Optional) vxlan vobj count

vxlan

(Optional) vxlan

vobj_list_header

(Optional) vobj list header

TABLE_vobj_id

(Optional) vobj_id table

vobj-id

(Optional) vobj id

Command Mode

  • /exec

show forwarding inconsistency

show forwarding [ ip | ipv4 ] [ unicast ] inconsistency [ suppress-transient ] [ vrf { <vrf-name> | all_vrfs } ] [ module { <module> | all_modules } ] [ __readonly__ [ <err_str> ] [ <cc_header> ] [ <table_id> ] [ <slot_id> ] [ <exec_time> ] [ <elapsed_time> ] [ <inconsis_adjs> ] [ TABLE_inconsistency_adjs { <id> <slot> [ <unit> ] <vrf> [ <ipaddr> ] [ <ipprefix> ] [ <interface> ] <reason> } ] [ <inconsis_routes> ] [ TABLE_inconsistency_routes { <id> <slot> [ <unit> ] <vrf> [ <ipaddr> ] [ <ipprefix> ] [ <interface> ] <reason> } ] [ <run_status> ] ]

Syntax Description

show

show

forwarding

Display Forwarding Information

ip

(Optional) ipv4

ipv4

(Optional) ipv4

unicast

(Optional) unicast

inconsistency

route inconsistency check

suppress-transient

(Optional) Supress Transient state

vrf

(Optional) check routes for a specific VRF

vrf-name

(Optional) VRF name

module

(Optional) check routes for a specific module

module

(Optional) module number

all_modules

(Optional) all module's

all_vrfs

(Optional) all vrf's

__readonly__

(Optional)

err_str

(Optional)

cc_header

(Optional)

table_id

(Optional)

slot_id

(Optional)

exec_time

(Optional)

elapsed_time

(Optional)

inconsis_adjs

(Optional)

TABLE_inconsistency_adjs

(Optional)

id

(Optional)

slot

(Optional)

unit

(Optional)

vrf

(Optional)

ipaddr

(Optional)

ipprefix

(Optional)

interface

(Optional)

reason

(Optional)

inconsis_routes

(Optional)

TABLE_inconsistency_routes

(Optional)

id

(Optional)

slot

(Optional)

unit

(Optional)

vrf

(Optional)

ipaddr

(Optional)

ipprefix

(Optional)

interface

(Optional)

reason

(Optional)

run_status

(Optional)

Command Mode

  • /exec

show forwarding interfaces

show forwarding interfaces [ module <module> ] [ __readonly__ TABLE_intf_str <intf> <v4adjcnt> <v6adjcnt> <v4rpfmode> <v6rpfmode> <mac> ]

Syntax Description

show

forwarding

fib information

interfaces

show fib interface info

__readonly__

(Optional)

TABLE_intf_str

(Optional) show interface string

intf

(Optional) interface name

module

(Optional) slot

module

(Optional) slot number

v4adjcnt

(Optional) count of v4 adjacencies

v6adjcnt

(Optional) count of v6 adjacencies

mac

(Optional) mac address

v4rpfmode

(Optional) v4 uRPF mode

v6rpfmode

(Optional) v6 uRPF mode

Command Mode

  • /exec

show forwarding ipv6

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } | table <table_id> ] ipv6 [ route | rnhdb ] [ recursive ] [ detail | summary | platform | partial | <prefix> [ longer-prefixes ] [ detail | platform ] | <address> [ detail | platform ] | interface <interface> | next-hop <nh> | attached | unresolved | adjacency { <aif> <anh> | drop | glean | punt } ] [ max-display-count <display_count> ] [ module <module> | vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } ] + [ __readonly__ [ <prefix_count> ] [ TABLE_vrf { [ <vrfname> ] [ <tblname> ] [ <tableid> ] [ TABLE_prefix { [ <pfx> ] [ <num_paths> ] [ <vobj-id> ] [ TABLE_path { [ <nexthop> | <special> ] [ <intf> ] [ <route_updates> ] [ <route_inserts> ] [ <route_deletes> ] [ <route_count> ] [ <path_count> ] [ TABLE_mask { [ <mask_length> ] [ <routes_per_mask> ] } ] } ] [ <hw_handle> ] [ <flags> ] [ <holder> ] [ <nxt_obj_type> ] [ <hw_idx_v6adj> ] [ <cmn-idx> ] [ <lif> ] [ <buf-idx> ] } ] } ] [ <packet_cnt> ] [ <byte_cnt> ] ]

Syntax Description

show

forwarding

display fib information

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

table

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

table_id

(Optional) table id in hex

ipv6

ipv6

route

(Optional) display IP routing table

platform

(Optional) one command to show pi and pd info together

rnhdb

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

recursive

(Optional) display routes with recursive next hops

detail

(Optional) show detailed information about the routes

summary

(Optional) display route counts

partial

(Optional) display routes with partial ECMPs

longer-prefixes

(Optional) display longer prefixes

interface

(Optional) display routes with this output i/f only

interface

(Optional) output interface

next-hop

(Optional) display routes with this next-hop only

attached

(Optional) display directly connected routes

unresolved

(Optional) display unresolved routes

adjacency

(Optional) display adjacency information

aif

(Optional) adjacency output interface

drop

(Optional) display routes via drop adjacency

glean

(Optional) display routes via glean adjacency

punt

(Optional) display routes via punt adjacency

module

(Optional) slot

module

(Optional) slot number

max-display-count

(Optional) displays max # of routes

display_count

(Optional) count

__readonly__

(Optional)

TABLE_vrf

(Optional) vrf table

vrfname

(Optional) VRF name

tblname

(Optional) table name

tableid

(Optional) table id

prefix_count

(Optional) total number of prefix in VRF

TABLE_prefix

(Optional) all xml prefix entries

pfx

(Optional) ipv6 prefix

num_paths

(Optional) no of paths

vobj-id

(Optional) vobj-id

TABLE_path

(Optional) path table

nexthop

(Optional) next hop address

special

(Optional) special adjacencies

intf

(Optional) output interface

route_updates

(Optional) route update in VRF

route_inserts

(Optional) route insert in VRF

route_deletes

(Optional) route delete in VRF

route_count

(Optional) total number of routes in VRF

path_count

(Optional) total number of paths in VRF

TABLE_mask

(Optional) mask table

mask_length

(Optional) length of mask

routes_per_mask

(Optional) routes per mask

hw_handle

(Optional) hw handle

flags

(Optional) flags

holder

(Optional) holder

nxt_obj_type

(Optional) next obj type

hw_idx_v6adj

(Optional) v6 adj hw idx

cmn-idx

(Optional) cmn idx

lif

(Optional) lif

buf-idx

(Optional) Buffer index

packet_cnt

(Optional) Packet count

byte_cnt

(Optional) Byte count

Command Mode

  • /exec

show forwarding ipv6 adjacency

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } ] ipv6 adjacency [ mpls ] [ nve ] [ <aif> ] [ <anh> ] [ detail | stats | platform ] [ module <module> ] [ __readonly__ [ <adj-count> ] [ TABLE_adj { [ <fec> ] <nexthop> <rewinfo> [ <interface> ] [ <pkts> ] [ <bytes> ] [ <bgp_rnh> ] [ <bgp_orig_as> ] [ <bgp_peer_as> ] [ <hh> ] [ <refcount> ] } ] [ TABLE_v6_adj { [ <nh> ] [ <rwinfo> ] [ <intf> ] [ <intf_idx> ] [ <hh> ] [ <refcnt> ] [ <flags> ] [ <holder> ] [ <pbr_cnt> ] [ <wccp_cnt> ] [ TABLE_index { [ <hw_adj> ] [ <cmn-idx> ] [ <lif> ] } ] } ] ]

Syntax Description

show

forwarding

display fib information

ipv6

ipv6

adjacency

display adjacency information

platform

(Optional) one command to show pi and pd info together

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

mpls

(Optional) mpls adjacency information

nve

(Optional) nve adjacency information

aif

(Optional) adjacency output interface

detail

(Optional) detail

stats

(Optional) adjacency statistics

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

adj-count

(Optional) total adj count

TABLE_adj

(Optional) Table Adjacency

fec

(Optional) FEC info

nexthop

(Optional) next hop address

rewinfo

(Optional) rewrite information

interface

(Optional) output interface

pkts

(Optional) packet stats

bytes

(Optional) bytes stats

bgp_rnh

(Optional) next hop address

bgp_orig_as

(Optional) bgp orig as

bgp_peer_as

(Optional) bgp peer as

hh

(Optional) Hardware Handle

refcount

(Optional) reference count

TABLE_v6_adj

(Optional) Table Adjacency

nh

(Optional) next hop address

rwinfo

(Optional) rewrite information

intf

(Optional) output interface

intf_idx

(Optional) Interface index

hh

(Optional) Hardware Handle

refcnt

(Optional) reference count

flags

(Optional) Adjacency flags

holder

(Optional) Holder bitmap

pbr_cnt

(Optional) PBR count

wccp_cnt

(Optional) WCCP count

TABLE_index

(Optional) HW index table

hw_adj

(Optional) v4 adj hw index

cmn-idx

(Optional) CMN Index

lif

(Optional) LIF

Command Mode

  • /exec

show forwarding ipv6 inconsistency

show forwarding ipv6 [ unicast ] inconsistency [ suppress-transient ] [ vrf { <vrf-name> | all_vrfs } ] [ module { <module> | all_modules } ] [ __readonly__ [ <err_str> ] [ <cc_header> ] [ <table_id> ] [ <slot_id> ] [ <exec_time> ] [ <elapsed_time> ] [ <inconsis_adjs> ] [ TABLE_inconsistency_adjs { <idipv6> <slotipv6> [ <unitipv6> ] <vrfipv6> [ <ipv6addr> ] [ <ipv6prefix> ] [ <interfaceipv6> ] <reasonipv6> } ] [ <inconsis_routes> ] [ TABLE_inconsistency_routes { <idipv6> <slotipv6> [ <unitipv6> ] <vrfipv6> [ <ipv6addr> ] [ <ipv6prefix> ] [ <interfaceipv6> ] <reasonipv6> } ] [ <run_status> ] ]

Syntax Description

show

show

forwarding

Display Forwarding Information

ipv6

ipv6

unicast

(Optional) unicast

inconsistency

route inconsistency check

suppress-transient

(Optional) Supress Transient state

vrf

(Optional) check routes for a specific VRF

vrf-name

(Optional) VRF name

module

(Optional) check routes for a specific module

module

(Optional) module number

all_modules

(Optional) all module's

all_vrfs

(Optional) all vrf's

__readonly__

(Optional)

err_str

(Optional)

cc_header

(Optional)

table_id

(Optional)

slot_id

(Optional)

exec_time

(Optional)

elapsed_time

(Optional)

inconsis_adjs

(Optional)

TABLE_inconsistency_adjs

(Optional)

idipv6

(Optional)

slotipv6

(Optional)

unitipv6

(Optional)

vrfipv6

(Optional)

interfaceipv6

(Optional)

reasonipv6

(Optional)

inconsis_routes

(Optional)

TABLE_inconsistency_routes

(Optional)

idipv6

(Optional)

slotipv6

(Optional)

unitipv6

(Optional)

vrfipv6

(Optional)

interfaceipv6

(Optional)

reasonipv6

(Optional)

run_status

(Optional)

Command Mode

  • /exec

show forwarding ipv6 multicast route

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | all } | table <tab_id> ] ipv6 multicast route { [ group { <group> | <group_addr> } [ source { <source> | <source_addr> } ] | module <module> | vrf { <vrf-name> | all } ] + | summary [ module <module> | vrf { <vrf-name> | <vrf-known-name> | all } ] + } [ __readonly__ [ <table_type> ] [ <vrfname> ] [ <table_id> ] [ <num_routes> <num_starg_routes> <num_sg_routes> <num_gprefix_routes> ] [ <num_groups> ] [ <num_sources> ] [ <num_prefix_insert_fail> ] [ [ TABLE_MROUTE_INFO <address> [ <src_len> <grp_len> ] [ <df_ordinal> ] [ <rpfif> ] [ <rpf_ifindex> ] <flag> [ <flag_value> ] <route_pkts> <route_bytes> <oiflist_id> <oif_count> <oiflist_flag> [ TABLE_OIF_INFO <oifindex> [ <vlan> ] [ TABLE_MCAST_OIF_INTF_INFO [ <oifname> ] [ <dvif> ] ] [ <platform_id> ] [ <encap_id> ] [ <hw_index> ] ] ] ] ]

Syntax Description

show

forwarding

display fib information

ipv6

ipv6

multicast

IPV6 related Multicast information

route

Multicast route information

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display information for all VRFs

table

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

tab_id

(Optional) table number

group

(Optional) Multicast IPv6 Group Address

source

(Optional) Multicast IPv6 Source Address

summary

display route counts

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

table_type

(Optional) Table Type

vrfname

(Optional) VRF name

table_id

(Optional) Table ID

num_routes

(Optional) Number of routes

num_starg_routes

(Optional) Number of (*,G) routes

num_sg_routes

(Optional) Number of (S,G) routes

num_gprefix_routes

(Optional) Number of (*,G-prefix) routes

num_groups

(Optional) Number of group entries in the table

num_prefix_insert_fail

(Optional) Prefix insert fail count

num_sources

(Optional) Number of (S, G) entries for the group address

TABLE_MROUTE_INFO

(Optional) Mroute info

address

(Optional) Mcast address

src_len

(Optional) Source Address Mask

grp_len

(Optional) Group address Mask

df_ordinal

(Optional) DF ordinal

rpfif

(Optional) RPF interface

rpf_ifindex

(Optional) RPF Interface ifIndex

flag

(Optional) Route type flag

flag_value

(Optional) hex value of route flag

route_pkts

(Optional) Route packet count

route_bytes

(Optional) Route bytes

oiflist_id

(Optional) OIF list Identifier

oif_count

(Optional) Number of OIFs

oiflist_flag

(Optional) OIF List flag

TABLE_OIF_INFO

(Optional) OIF Info

oifindex

(Optional) OIF Interface ifIndex

vlan

(Optional) Vlan id

TABLE_MCAST_OIF_INTF_INFO

(Optional) OIF Interfaces

oifname

(Optional) OIF Interface name

dvif

(Optional) DVIF

platform_id

(Optional) Platform-index

encap_id

(Optional) Encap ID

hw_index

(Optional) Harware index

Command Mode

  • /exec

show forwarding kvfib cache on

show forwarding kvfib cache { on | off }

Syntax Description

show

forwarding

fib information

kvfib

kvfib

cache

cache

on

set variable

off

reset variable

Command Mode

  • /exec

show forwarding l2 multicast

show forwarding l2 multicast { [ { vlan <vlan-id> [ { group <grpaddr> source <srcaddr> } | { group <v6grpaddr> source <v6srcaddr> } | destination-mac <dstmac> ] } ] } [ vdc <vdc-id> ] [ module <num> ] [ __readonly__ [ TABLE_L2_MCAST_INFO <vlan_id> [ <group> ] [ <group_v6> ] [ <source> ] [ <source_v6> ] [ <dmac> ] <epoch> <resource_id> <dest_index> [ <hw_handle> ] [ <text> ] [ <value> ] ] ]

Syntax Description

show

Show running system information

forwarding

Forwarding information

l2

L2 related information

multicast

Multicast related information

vlan

(Optional) Information Specific to a Vlan

vlan-id

(Optional) Vlan id value

group

(Optional) (S,G) specific information

grpaddr

(Optional) Group address

source

(Optional) source specific information

srcaddr

(Optional) Source address

destination-mac

(Optional) Destination MAC address

dstmac

(Optional) Ethernet MAC address

vdc

(Optional) VDC

vdc-id

(Optional) VDC id

module

(Optional) Slot

num

(Optional) Slot number

__readonly__

(Optional)

TABLE_L2_MCAST_INFO

(Optional) L2 Multicast Info

vlan_id

(Optional) Vlan Identifier

group

(Optional) Multicast IPv4 Group Address

group_v6

(Optional) Multicast IPv6 Group Address

source

(Optional) Multicast IPv4 Source Address

source_v6

(Optional) Multicast IPv6 Source Address

dmac

(Optional) Destination MAC address

epoch

(Optional) Epoch number

resource_id

(Optional) Resource Identifier

dest_index

(Optional) Destination Index Identifier

hw_handle

(Optional) Hardware Handle

text

(Optional) String

value

(Optional) Value

Command Mode

  • /exec

show forwarding l2vpn label vpls

show forwarding l2vpn label [ <label_id> ] vpls [ module module ] [ __readonly__ <label_id> ]

Syntax Description

show

show

forwarding

forwarding

l2vpn

l2vpn forwarding

label

VC label

label_id

(Optional) VC label

vpls

VPLS

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

label_id

(Optional) Label ID

Command Mode

  • /exec

show forwarding l2vpn label xconnect

show forwarding l2vpn label [ <label_id> ] xconnect [ module module ] [ __readonly__ <label_id> ]

Syntax Description

show

show

forwarding

forwarding

l2vpn

l2vpn forwarding

label

VC label

label_id

(Optional) VC label

xconnect

xconnect or VPWS

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

label_id

(Optional) Label ID

Command Mode

  • /exec

show forwarding l2vpn vlan

show forwarding l2vpn vlan [ <vlan_id> ] [ module <module> ] [ __readonly__ <vlan> ]

Syntax Description

show

show

forwarding

forwarding

l2vpn

l2vpn forwarding

vlan

vlan

vlan_id

(Optional) vlan id

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

vlan

(Optional) vlan

Command Mode

  • /exec

show forwarding mpls

show forwarding mpls [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } [ label <label-id> | <prefix> | <v6prefix> ] | table <table_id> [ label <label-id> | <prefix> | <v6prefix> ] | label-space <label-space-id> | label <label-id> | <prefix> | <v6prefix> ] [ stats ] [ module <module> ] [ implicit ] [ platform ] [ __readonly__ [ { TABLE_mpls <label> [ { TABLE_table_id [ <out-table-id> ] [ <fec> ] [ <out-ip> ] [ <out-intf> ] [ <out-label> ] [ <out-op> ] [ <hh> ] [ <ref-count> ] [ <hw-index> ] } ] [ <in-pkts> ] [ <in-bytes> ] [ <swap-out-pkts> ] [ <swap-out-bytes> ] [ <tunnel-out-pkts> ] [ <tunnel-out-bytes> ] } ] ]

Syntax Description

show

show

forwarding

forwarding

mpls

mpls forwarding

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known vrf name

vrf-all

(Optional) Display information for all VRFs

table

(Optional) display info per vpn-id

table_id

(Optional) table number

label-space

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

label-space-id

(Optional) label space id

label

(Optional) mpls labels

label-id

(Optional) mpls label value

prefix

(Optional) Labels for single exact match route

module

(Optional) slot

module

(Optional) slot number

stats

(Optional) Label Statistics

implicit

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

platform

(Optional) Display platform information

__readonly__

(Optional)

TABLE_mpls

(Optional)

label

(Optional) mpls label value

TABLE_table_id

(Optional) Table table id

out-table-id

(Optional) Output table-id

fec

(Optional) Prefix/Tunnel ID

out-ip

(Optional) Output Next Hop

out-intf

(Optional) Output Interface

out-label

(Optional) Output Label

out-op

(Optional) Output Label op

hh

(Optional) Hardware Handle

ref-count

(Optional) Ref Count

hw-index

(Optional) HW index for adj

in-pkts

(Optional) Label Input Packet Stats

in-bytes

(Optional) Label Input Bytes Stats

swap-out-pkts

(Optional) Label Swap Output Packet Stats

swap-out-bytes

(Optional) Label Swap Output Bytes Stats

tunnel-out-pkts

(Optional) Label Tunnel Output Packet Stats

tunnel-out-bytes

(Optional) Label Tunnel Output Bytes Stats

Command Mode

  • /exec

show forwarding mpls drop-stats

show forwarding mpls drop-stats [ platform | label0-fwd-stats ] [ __readonly__ [ { TABLE_drop_stats <unit-number> <pkts> <bytes> } ] ]

Syntax Description

show

show

forwarding

forwarding

mpls

mpls forwarding

drop-stats

MPLS dropped packets

platform

(Optional) command to display stats per chip

label0-fwd-stats

(Optional) command to display stats for label0

__readonly__

(Optional)

TABLE_drop_stats

(Optional) Table for mpls drop stats

unit-number

(Optional) unit number

pkts

(Optional) Label Packet Stats

bytes

(Optional) Label Bytes Stats

Command Mode

  • /exec

show forwarding mpls ecmp

show forwarding mpls ecmp [ module <module> ] [ platform ] [ __readonly__ [ { TABLE_ecmp [ <type> ] [ <num_paths> ] [ <ip_paths> ] [ <mpls_paths> ] [ <ecmp_hash> ] [ <holder> ] [ <refcount> ] [ <hw_index> ] [ <fec> ] [ { TABLE_ecmp_paths [ <out-intf> ] [ <out-ip> ] [ <label-info> ] [ <refcount> ] [ <hh> ] [ <ecmp-type> ] } ] } ] ]

Syntax Description

show

show

forwarding

display fib information

mpls

mpls forwarding

ecmp

mpls ecmps

module

(Optional) slot

module

(Optional) slot number

platform

(Optional) show pd info

__readonly__

(Optional)

TABLE_ecmp

(Optional)

type

(Optional) ecmp type

num_paths

(Optional) No of paths

ip_paths

(Optional) No of ip paths

mpls_paths

(Optional) No of mpls paths

ecmp_hash

(Optional) ecmp hash

holder

(Optional) holder bitmap

refcount

(Optional) refcount

hw_index

(Optional) Hw index

fec

(Optional) FEC

TABLE_ecmp_paths

(Optional)

out-intf

(Optional) Output Interface

out-ip

(Optional) Output Next Hop

label-info

(Optional) label info

refcount

(Optional) refcount

hh

(Optional) Hardware Handle

ecmp-type

(Optional) type for per path in ecmp

Command Mode

  • /exec

show forwarding mpls eompls

show forwarding mpls eompls [ peers { <addr> | all } ] [ __readonly__ [ { TABLE_peer_ip <peer_ip> <peer_id> <vlan_bmp> <rx_pkts> <rx_bytes> } ] ]

Syntax Description

show

Show

forwarding

Forwarding information

mpls

mpls forwarding

eompls

eompls

peers

(Optional) nve peers

addr

(Optional) peer ipaddress

all

(Optional) Display peer info for all peers

__readonly__

(Optional)

TABLE_peer_ip

(Optional)

peer_ip

(Optional) peer address

peer_id

(Optional) peer id

vlan_bmp

(Optional) vlan bitmap

rx_pkts

(Optional) packet stats

rx_bytes

(Optional) bytes stats

Command Mode

  • /exec

show forwarding mpls eompls ir

show forwarding mpls eompls ir { [ vlan [ all | <vlan_id> ] ] | [ peer [ all | <peer_ip> ] ] } [ __readonly__ [ { TABLE_VLAN <vlan_id> <vni> <ifindex> <plt_space> <bitmap> <peer> + <marked> + } ] [ { TABLE_ONE_PEER <peer> <id> <repl_id> <oif> <path_intf> + <vcount> <vlan_id> + <plt_space> } ] ]

Syntax Description

show

Show running system information

forwarding

Forwarding information

mpls

mpls

eompls

eompls

ir

ir

vlan

(Optional) vlans all

all

(Optional) all

vlan_id

(Optional) vlan-id

peer

(Optional) peers-all

all

(Optional) all

peer_ip

(Optional) show detailed info for peer

__readonly__

(Optional)

TABLE_VLAN

(Optional) vlan peer ids table

vlan_id

(Optional) vlan id

vni

(Optional) vni

ifindex

(Optional) ifindex

plt_space

(Optional) platform space

bitmap

(Optional) peer bitmap

peer

(Optional) peer_address

marked

(Optional) marked

TABLE_ONE_PEER

(Optional) vlan peer ids table

peer

(Optional) vlan id

id

(Optional) vni

repl_id

(Optional) repli id

oif

(Optional) ifindex

path_intf

(Optional) pathintf name

vcount

(Optional) vlan count

vlan_id

(Optional) vlanid

plt_space

(Optional) platform space

Command Mode

  • /exec

show forwarding mpls option_b

show forwarding mpls option_b [ label <label> ] [ module <module> ] [ platform ] [ __readonly__ [ { TABLE_mpls_opt_b <label> [ <prefix> ] [ <v6prefix> ] [ <nxhop> ] [ <out-interface> ] [ <out-op> ] } ] ]

Syntax Description

show

show

forwarding

forwarding

mpls

mpls forwarding

option_b

Option B

label

(Optional) mpls labels

label

(Optional) mpls label value

module

(Optional) slot

module

(Optional) slot number

platform

(Optional) show pd info

__readonly__

(Optional)

TABLE_mpls_opt_b

(Optional)

label

(Optional) mpls label value

prefix

(Optional) Output Interface

nxhop

(Optional) Output Next Hop

out-interface

(Optional) Output Label op

out-op

(Optional) Output Label op

Command Mode

  • /exec

show forwarding mpls srte module

show forwarding mpls srte module [ <module> ] [ __readonly__ [ { TABLE_srte <table-id> [ { TABLE_binding_label <binding-label> <parent-table-id> <parent-vobj-id> [ { TABLE_prefix <prefix> <vrf> } ] } ] } ] ]

Syntax Description

show

Show

forwarding

Forwarding information

mpls

mpls forwaring

srte

SR Traffic Engineering

module

slot

module

(Optional) slot number

__readonly__

(Optional)

TABLE_srte

(Optional)

table-id

(Optional) table id

TABLE_binding_label

(Optional)

binding-label

(Optional) binding label

parent-table-id

(Optional) parent table id

parent-vobj-id

(Optional) parent vobj id

TABLE_prefix

(Optional)

prefix

(Optional) prefix

vrf

(Optional) vrf

Command Mode

  • /exec

show forwarding mpls summary

show forwarding mpls summary [ module <module> ] [ __readonly__ [ { TABLE_labels <space> <count> } <total_deagg_labels> <feature_evpn_status> ] ]

Syntax Description

show

show

forwarding

display fib information

mpls

mpls forwarding

summary

summary

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

TABLE_labels

(Optional)

space

(Optional) label space

count

(Optional) number of labels

total_deagg_labels

(Optional) total deagg labels

feature_evpn_status

(Optional) feature evpn status

Command Mode

  • /exec

show forwarding multicast-sr loopback interface

show forwarding multicast-sr loopback interface [ __readonly__ [ <port-num> ] ]

Syntax Description

show

forwarding

display fib information

multicast-sr

multicast service reflect information

interface

loopback interface

loopback

loopback interface

__readonly__

(Optional)

port-num

(Optional) Port number

Command Mode

  • /exec

show forwarding multicast-sr mac-trap-db

show forwarding multicast-sr mac-trap-db [ __readonly__ { [ TABLE_mac_trap_db <mac-addr> <mac-trap-id> <ref-cnt> ] <total-count> } ]

Syntax Description

show

Show running system information

forwarding

display platform fib information

multicast-sr

multicast service reflect information

mac-trap-db

display internal mac-trap db

__readonly__

(Optional)

TABLE_mac_trap_db

(Optional) display internal mac-trap db

mac-addr

(Optional) MAC address

mac-trap-id

(Optional) MAC trap ID

ref-cnt

(Optional) Reference Count

total-count

(Optional) total count

Command Mode

  • /exec

show forwarding multicast outgoing-interface-list

show forwarding multicast outgoing-interface-list { L2 | L3 | vxlan-encap | vxlan-ir-dci-encap | mvpn } [ platform ] [ module <module> ] [ <index> ] [ __readonly__ [ <refcount> ] [ <total_l2_oiflist> ] [ <total_l3_oiflist> ] [ <slot> ] [ TABLE_MCAST_OIF_INFO [ <oiflist_idx> ] [ <vlan> ] [ <num_oif> ] [ TABLE_MCAST_OIF_INTF_INFO [ <intf> ] [ <dvif> ] ] [ <encap_id> ] [ <hw_oiflist_idx> ] [ <mcidx> ] ] ]

Syntax Description

show

forwarding

Forwarding information

multicast

Multicast IPv4 information

outgoing-interface-list

show outgoing interface list info

L2

Layer 2 oiflist

L3

Layer 3 oiflist

vxlan-encap

vxlan-encap oiflist

vxlan-ir-dci-encap

vxlan-ir-dci-encap oiflist

mvpn

MVPN oiflist

platform

(Optional) Display PI/PD

module

(Optional) slot

module

(Optional) slot number

index

(Optional) Outgoing Interface List Index

__readonly__

(Optional)

refcount

(Optional) Reference count

total_l2_oiflist

(Optional) total l2 oiflist

total_l3_oiflist

(Optional) total l3 oiflist

slot

(Optional) slot number

TABLE_MCAST_OIF_INFO

(Optional) Mcast OIF Info

oiflist_idx

(Optional) Outgoing Interface List Index

vlan

(Optional) Vlan id

num_oif

(Optional) Number of outgoing interfaces

TABLE_MCAST_OIF_INTF_INFO

(Optional) OIF Interfaces

intf

(Optional) OIF name

dvif

(Optional) DVIF

encap_id

(Optional) encap_id

hw_oiflist_idx

(Optional) Hardware Outgoing Interface List Index

mcidx

(Optional) MC Index

Command Mode

  • /exec

show forwarding multicast pvlan replicated-routes

show forwarding multicast pvlan replicated-routes [ { group <group_addr> [ [ source <source_addr> [ vlan <vlan_id> ] ] | vlan <vlan_id> ] | vlan <vlan_id> } ] [ __readonly__ [ { TABLE_entry <sh_vlan> <sh_group> <sh_source> } ] ]

Syntax Description

show

forwarding

display fib information

multicast

Multicast IPv4 information

pvlan

PVLAN information

replicated-routes

Display replicated route database

group

(Optional) group address

group_addr

(Optional) group address

source

(Optional) source address

source_addr

(Optional) source address

vlan

(Optional) vlan id

vlan_id

(Optional) vlan id

__readonly__

(Optional)

TABLE_entry

(Optional)

sh_vlan

(Optional) vlan id

sh_group

(Optional) group address

sh_source

(Optional) source address

Command Mode

  • /exec

show forwarding multicast route

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | all } | table <table_id> ] [ ipv4 ] multicast route [ platform ] { [ group { <gaddr> [ <mask> ] | <gprefix> } [ source { <saddr> [ <smask> ] | <sprefix> } ] | module <module> | vrf { <vrf-name> | <vrf-known-name> | all } ] + | summary [ module <module> | vrf { <vrf-name> | <vrf-known-name> | all } ] + } [ __readonly__ [ <table_type> ] [ <vrfname> ] [ <table_id> ] [ <num_routes> <num_starg_routes> <num_sg_routes> <num_gprefix_routes> ] [ <num_groups> ] [ <num_sources> ] [ <num_prefix_insert_fail> ] [ [ TABLE_MROUTE_INFO <mcast_addr> [ <src_len> <grp_len> ] [ <df_ordinal> ] [ <rpfif> ] [ <rpf_ifindex> ] <flag> [ <flag_value> ] <route_pkts> <route_bytes> <oiflist_id> <oif_count> [ <refcount> ] <oiflist_flag> [ TABLE_OIF_INFO <oifindex> [ TABLE_MCAST_VLAN_INFO [ <vlan> ] [ TABLE_MCAST_OIF_INFO [ <oifname> ] [ <dvif> ] ] ] [ <platform_id> ] [ <encap_id> ] [ TABLE_MCAST_CORE_OIF_INFO [ <core_oifname> ] ] [ <hw_index> ] [ <oif_pkts> <oif_bytes> ] ] ] ] ]

Syntax Description

show

forwarding

Forwarding information

ipv4

(Optional) ipv4

multicast

Multicast IPv4 information

route

Mcast route information

platform

(Optional) Platform Details

table

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

table_id

(Optional) table number

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

all

(Optional) Display information for all VRFs

group

(Optional) Multicast IPv4 Group specific info

gaddr

(Optional) Multicast IPv4 Group Address

mask

(Optional) Multicast IPv4 Group Address mask

gprefix

(Optional) Multicast IPv4 Group Prefix

source

(Optional) Multicast IPv4 Source specific info

saddr

(Optional) Multicast IPv4 Source Address

smask

(Optional) Multicast IPv4 Source Address mask

sprefix

(Optional) Multicast IPv4 Source Prefix

summary

display route counts

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

table_type

(Optional) Table Type

vrfname

(Optional) VRF name

table_id

(Optional) Table ID

num_routes

(Optional) Number of routes

num_starg_routes

(Optional) Number of (*,G) routes

num_sg_routes

(Optional) Number of (S,G) routes

num_gprefix_routes

(Optional) Number of (*,G-prefix) routes

num_groups

(Optional) Number of group entries in the table

num_prefix_insert_fail

(Optional) Prefix insert fail count

num_sources

(Optional) Number of (S, G) entries for the group address

TABLE_MROUTE_INFO

(Optional) Mroute info

mcast_addr

(Optional) Mcast address

src_len

(Optional) Source Address Mask

grp_len

(Optional) Group address Mask

df_ordinal

(Optional) DF ordinal

rpfif

(Optional) RPF interface

rpf_ifindex

(Optional) RPF Interface ifIndex

flag

(Optional) Route type flag

flag_value

(Optional) hex value of route flag

route_pkts

(Optional) Route packet count

route_bytes

(Optional) Route bytes

oiflist_id

(Optional) OIF list Identifier

oif_count

(Optional) Number of OIFs

oiflist_flag

(Optional) OIF List flag

refcount

(Optional) OIF list Reference Count

TABLE_OIF_INFO

(Optional) OIF Info

oifindex

(Optional) OIF Interface ifIndex

TABLE_MCAST_VLAN_INFO

(Optional) Vlan Interfaces

vlan

(Optional) Vlan id

TABLE_MCAST_OIF_INFO

(Optional) OIF Interfaces

oifname

(Optional) OIF Interface name

dvif

(Optional) DVIF

TABLE_MCAST_CORE_OIF_INFO

(Optional) Core-facing OIF Interfaces

core_oifname

(Optional) Core-facing OIF Interface name

platform_id

(Optional) Platform-index

encap_id

(Optional) Encap ID

hw_index

(Optional) Harware index

oif_pkts

(Optional) OIF packets

oif_bytes

(Optional) OIF bytes

Command Mode

  • /exec

show forwarding nve l2 ingress-replication-peers

show forwarding nve l2 ingress-replication-peers [ ipv4 <peer_ip> | ipv6 <v6_peer_ip> ] + [ __readonly__ [ { TABLE_VLAN <vlan_id> <vni> <ifindex> <plt_space> <peer_bmp> <peer> + } { TABLE_PSS_VLAN <vlan_pss_id> <VNI> <vtep> <peercnt> <pss_peer_bmp> { <pss_peer> <marked> } + } ] + [ [ <peer> <id> <repl_id> <oif> <hash_algo> <path_intf> + <vcount> <vlan_id> + <resync_vcount> <resync_vlan_id> + [ <path> <hash> <flags> <nh> <intf> + ] ] [ <pss_peer> <pss_id> <pss_repl_id> <pss_oif> <pss_hash_algo> <pss_path_intf> + <pss_vcount> <vlan_pss_id> + [ <pss_path> <pss_hash> <pss_flags> <pss_nh> <pss_intf> + ] ] ] ]

Syntax Description

show

show

forwarding

display fib information

nve

nve related info

l2

L2 info

ingress-replication-peers

ingress replication peer info

ipv4

(Optional) ipv4 peer

peer_ip

(Optional) show detailed info of a peer

ipv6

(Optional) ipv6 peer

__readonly__

(Optional)

TABLE_VLAN

(Optional) vlan peer ids table

vlan_id

(Optional) vlan id

vni

(Optional) vni

ifindex

(Optional) ifindex

plt_space

(Optional) platform space

peer_bmp

(Optional) peer bitmap

peer

(Optional) peer_address

TABLE_PSS_VLAN

(Optional) vlan-peer in pss

vlan_pss_id

(Optional) pss_peer_id

VNI

(Optional) vni

vtep

(Optional) vtep

peercnt

(Optional) peer count

pss_peer_bmp

(Optional) PSS peer bitmap

pss_peer

(Optional) peer address

marked

(Optional) marked

peer

(Optional) peer

id

(Optional) id

repl_id

(Optional) repl_id

oif

(Optional) oif

path_intf

(Optional) path intf name

hash_algo

(Optional) hash algo used

vcount

(Optional) vlan count

vlan_id

(Optional) vlan id

resync_vcount

(Optional) resync vlan count

resync_vlan_id

(Optional) resync vlan id

path

(Optional) ecmp path

hash

(Optional) ecmp hash

flags

(Optional) ecmp flags

nh

(Optional) ecmp nh

intf

(Optional) ecmp interfaces

pss_peer

(Optional) peer

pss_id

(Optional) id

pss_repl_id

(Optional) repl_id

pss_oif

(Optional) oif

pss_path_intf

(Optional) path intf name

pss_hash_algo

(Optional) hash algo used

pss_vcount

(Optional) vlan count

vlan_pss_id

(Optional) vlan id

pss_path

(Optional) pss path

pss_hash

(Optional) pss hash

pss_flags

(Optional) pss flags

pss_nh

(Optional) pss nh

pss_intf

(Optional) pss intf

Command Mode

  • /exec

show forwarding nve l3 adjacency tunnel

show forwarding nve l3 adjacency tunnel [ <tunnel_id> | all ] [ bd <bd_id> | detail | module <module> | table <table_id> ] [ __readonly__ TABLE_nvel3adj <tunnel_id> <bd_id> <table_id> <VNI> <DownStream> <Drop> <Refcount> <Origin> <State> <Del> [ <sw_index> <hw_index0> <hw_index1> <hw_index2> ] ]

Syntax Description

show

forwarding

display fib information

nve

nve related info

l3

Layer 3

adjacency

Adjacency info

tunnel

VXLAN tunnel

tunnel_id

(Optional) tunnel_id

all

(Optional) show adjacency info for all peers

bd

(Optional) BD info

bd_id

(Optional) bd id

detail

(Optional) Show detailed information

module

(Optional) Slot/module

module

(Optional) Slot/module number

table

(Optional) Tenant table-id

table_id

(Optional) tenant table-id

__readonly__

(Optional)

TABLE_nvel3adj

(Optional)

tunnel_id

(Optional) tunnel_id

bd_id

(Optional) bd id

table_id

(Optional) tenant table-id

VNI

(Optional) vni

DownStream

(Optional) DownStream

Drop

(Optional) Drop

Refcount

(Optional) Refcount

Origin

(Optional) origin

State

(Optional) state

Del

(Optional) del

sw_index

(Optional)

hw_index0

(Optional)

hw_index1

(Optional)

hw_index2

(Optional)

Command Mode

  • /exec

show forwarding nve l3 adjacency v6-tunnel

show forwarding nve l3 adjacency v6-tunnel [ <peer-ip> | all ] [ bd <bd_id> | detail | module <num> | table <table_id> ] [ __readonly__ TABLE_nvel3adj <peer-ip> <bd_id> <table_id> <VNI> <Drop> <Refcount> <Origin> <State> <Del> <sw_index> <hw_index0> <hw_index1> <hw_index2> ]

Syntax Description

show

forwarding

display fib information

nve

nve related info

l3

Layer 3

adjacency

Adjacency info

v6-tunnel

VXLAN V6 tunnel

all

(Optional) Show adjacency for all peers

bd

(Optional) BD info

bd_id

(Optional) bd id

detail

(Optional) Show detailed information

module

(Optional) Slot/module

num

(Optional) Slot/module number

table

(Optional) Tenant table-id

table_id

(Optional) tenant table-id

__readonly__

(Optional)

TABLE_nvel3adj

(Optional)

bd_id

(Optional) bd id

table_id

(Optional) tenant table-id

VNI

(Optional) vni

Drop

(Optional) Drop

Refcount

(Optional) Refcount

Origin

(Optional) origin

State

(Optional) state

Del

(Optional) del

sw_index

(Optional)

hw_index0

(Optional)

hw_index1

(Optional)

hw_index2

(Optional)

Command Mode

  • /exec

show forwarding nve l3 ecmp

show forwarding nve l3 ecmp [ __readonly__ { TABLE_nvel3ecmp <hw_index> <ecmp_hash> <num_paths> <table_id> <flags> <adj_flags> <ref_count> { TABLE_tunnel_info [ <tunnel_id> | <tunnel_ip> ] <segment_id> } <hw_ecmp_index0> <hw_ecmp_index1> <hw_ecmp_index2> } ]

Syntax Description

show

forwarding

display fib information

nve

nve related info

l3

Layer 3

ecmp

nve ecmp info

__readonly__

(Optional)

TABLE_nvel3ecmp

(Optional) nve l3 ecmp table

hw_index

(Optional) hw_index address pointer

ecmp_hash

(Optional) ecmp hash

num_paths

(Optional) numer of members in ECMP

table_id

(Optional) table id

flags

(Optional) flags

adj_flags

(Optional) adj flags

ref_count

(Optional) num of references

TABLE_tunnel_info

(Optional)

tunnel_id

(Optional) tunnel id

tunnel_ip

(Optional) v6 tunnel ip

segment_id

(Optional) segment id

hw_ecmp_index0

(Optional) HW ECMP Index Unit 0

hw_ecmp_index1

(Optional) HW ECMP Index Unit 1

hw_ecmp_index2

(Optional) HW ECMP Index Unit 2

Command Mode

  • /exec

show forwarding nve l3 peers

show forwarding nve l3 peers [ peers <peer_id> | tunnel <tunnel_id> | detail | module <module> ] + [ __readonly__ { TABLE_l3peers <tunnel_id> <peer_id> <peer_address> <interface> <rmac> <origin> <state> <del> <count> } ]

Syntax Description

show

show

forwarding

display fib information

nve

nve related info

l3

Layer 3

peers

nve peers

peer_id

(Optional) nve peer-id

tunnel

(Optional) VXLAN tunnel

tunnel_id

(Optional) Unique identifier for the tunnel

detail

(Optional) Show detailed information

module

(Optional) Slot/module

module

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_l3peers

(Optional) all l3 nve peers

tunnel_id

(Optional) tunnel_id

peer_id

(Optional) peer_id

peer_address

(Optional) peer_address

interface

(Optional) interface

rmac

(Optional) rmac

origin

(Optional) origin

state

(Optional) state

del

(Optional) del

count

(Optional) count

Command Mode

  • /exec

show forwarding nve underlay-interfaces

show forwarding nve underlay-interfaces [ __readonly__ { <broadcast_status> <broadcast_level> <multicast_status> <multicast_level> <unicast_status> <unicast_level> <no_of_uplink_interfaces> } [ { TABLE_uplinks <ifindex> <peerid_bmp> <is_dci> [ <phy_if> ] } ] ]

Syntax Description

show

show

forwarding

display fib information

nve

NVE related info

underlay-interfaces

underlay interfaces info

__readonly__

(Optional)

broadcast_status

(Optional) status

broadcast_level

(Optional) broadcast level

multicast_status

(Optional) multicast status

multicast_level

(Optional) multicast level

unicast_status

(Optional) unitcast status

unicast_level

(Optional) unicast level

no_of_uplink_interfaces

(Optional) Number of uplink interfaces

TABLE_uplinks

(Optional)

ifindex

(Optional) uplink ifindex

phy_if

(Optional) uplink physical interface

peerid_bmp

(Optional) peerid bitmap

is_dci

(Optional) dci flag

Command Mode

  • /exec

show forwarding otv

show forwarding otv <intf> [ peer <peer-id> ] [ module <module> ] [ __readonly__ <vlan> <peer-id> <peer_vlan_count><tunnel_ifindex><tunnel_ifname> ]

Syntax Description

show

forwarding

fib information

otv

overlay-transport-virtualization

intf

overlay interface

peer

(Optional) overlay peer

peer-id

(Optional) overlay peer-id

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

vlan

(Optional) Vlan information

peer-id

(Optional) peer-id

Command Mode

  • /exec

show forwarding otv ipv6 multicast route

show forwarding otv ipv6 multicast route [ vlan <vlan_id> ] [ module <module> ] [ __readonly__ [ <table_type> ] [ <vlan-id> ] [ <replicator> ] [ <num_routes> ] [ <num_starg_routes> ] [ <num_sg_routes> ] [ <num_gprefix_routes> ] [ <num_prefix_insert_fail> ] [ <num_groups> ] [ <num_sources> ] [ { TABLE_otv_mroute [ <src_addr> ] [ <src_len> ] [ <grp_addr> ] [ <grp_len> ] [ <df_ordinal> ] [ <rpfif> ] [ <flag> ] [ <route_pkts> ] [ <route_bytes> ] [ <otv_route_pkts> ] [ <otv_route_bytes> ] [ { TABLE_OIF <oif_count> [ <oiflist_id> ] [ <index> ] [ <refcount> ] [ { TABLE_OIFLIST <oifindex> [ <oif_pkts> ] [ <oif_bytes> ] [ <src_addr> ] [ <src_len> ] [ <oifname> ] [ <vlanid> ] [ <grp_addr> ] [ <grp_len> ] [ <otv_src_addr> ] [ <otv_grp_addr> ] } ] } ] } ] ]

Syntax Description

show

show

forwarding

forwarding

otv

over-the-top virtualization

ipv6

ipv6

multicast

Multicast IPv6 information

route

Mcast route information

vlan

(Optional) vlan

vlan_id

(Optional) vlan id

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

table_type

(Optional) Table Type

vlan-id

(Optional) vlan id

replicator

(Optional) replicator name

num_routes

(Optional) Number of routes

num_starg_routes

(Optional) Number of (*,G) routes

num_sg_routes

(Optional) Number of (S,G) routes

num_gprefix_routes

(Optional) Number of (*,G-prefix) routes

num_prefix_insert_fail

(Optional) Prefix insert fail count

num_groups

(Optional) Number of group entries in the table

num_sources

(Optional) Number of (S, G) entries for the group address

TABLE_otv_mroute

(Optional)

src_addr

(Optional) Ipv6 address string

src_len

(Optional) Source Address Mask

grp_addr

(Optional) Ipv6 address string

grp_len

(Optional) Group address Mask

df_ordinal

(Optional) DF ordinal

rpfif

(Optional) RPF interface

flag

(Optional) Route type flag

route_pkts

(Optional) Route packet count

route_bytes

(Optional) Route bytes

otv_route_pkts

(Optional) OTV Route packet count

otv_route_bytes

(Optional) OTV Route bytes

TABLE_OIF

(Optional)

oif_count

(Optional) Number of OIFs

oiflist_id

(Optional) OIF list Identifier

index

(Optional) outgoing interface list index

refcount

(Optional) reference count

TABLE_OIFLIST

(Optional)

oifindex

(Optional) OIF Interface ifIndex

oif_pkts

(Optional) OIF packets

oif_bytes

(Optional) OIF bytes

src_addr

(Optional) Multicast IPv4 Source Address

src_len

(Optional) Source Address Mask

oifname

(Optional) OIF Interface name

vlanid

(Optional) vlan id of the route

grp_addr

(Optional) Multicast IPv4 Group Address

grp_len

(Optional) Group address Mask

otv_src_addr

(Optional) Multicast IPv4 Source Address

otv_grp_addr

(Optional) Multicast IPv4 Group Address

Command Mode

  • /exec

show forwarding otv multicast outgoing-interface-list

show forwarding otv multicast outgoing-interface-list [ __readonly__ { TABLE_OIF <index> [ <refcount> ] [ <intf> ] [ { TABLE_OIFLIST <oifindex> [ <src_addr> ] [ <src_len> ] [ <oifname> ] [ <vlanid> ] [ <grp_addr> ] [ <grp_len> ] } ] } ]

Syntax Description

show

forwarding

Forwarding information

otv

over-the-top virtualization

multicast

Multicast IPv4 information

outgoing-interface-list

show outgoing interface list info

__readonly__

(Optional)

TABLE_OIF

(Optional) outgoing interface list table

index

(Optional) outgoing interface list index

refcount

(Optional) reference count

intf

(Optional) interface name

TABLE_OIFLIST

(Optional) outgoing interface list table

oifindex

(Optional) OIF Interface ifIndex

src_addr

(Optional) Multicast IPv4 Source Address

src_len

(Optional) Source Address Mask

oifname

(Optional) OIF Interface name

vlanid

(Optional) vlan id of the route

grp_addr

(Optional) Multicast IPv4 Group Address

grp_len

(Optional) Group address Mask

Command Mode

  • /exec

show forwarding otv multicast route

show forwarding otv multicast route [ [ vlan <vlan-id> ] | [ softwarebd <software-bd> ] ] [ module <module> ] [ __readonly__ <replicator> ]

Syntax Description

show

show

forwarding

forwarding

otv

over-the-top virtualization

multicast

Multicast IPv4 information

route

Mcast route information

vlan

(Optional) vlan

vlan-id

(Optional) vlan id

softwarebd

(Optional) Software Bridge Domain

software-bd

(Optional) Software bd

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

replicator

(Optional) replicator name

Command Mode

  • /exec

show forwarding otv vlan

show forwarding otv vlan [ <vlan_id> ] [ module <module> ] [ __readonly__ <vlan> ]

Syntax Description

show

show

forwarding

forwarding

otv

otv

vlan

vlan

vlan_id

(Optional) vlan id

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

vlan

(Optional) vlan

Command Mode

  • /exec

show forwarding proactive-cc inconsistencies

show forwarding proactive-cc inconsistencies [ all ] [ __readonly__ [ <cc_status> ] [ TABLE_v4adj_hdr <incons_v4_adjs> [ TABLE_v4_adjs <id> <slot> <vrf> <ipaddr> <intf> <reason> <time> ] ] [ TABLE_v4route_hdr <incons_v4_routes> [ TABLE_v4_routes <id> <slot> <vrf> <ipprefix> <reason> <time> ] ] [ TABLE_v6adj_hdr <incons_v6_adjs> [ TABLE_v6_adjs <id> <slot> <vrf> <ipv6addr> <intf> <reason> <time> ] ] [ TABLE_v6route_hdr <incons_v6_routes> [ TABLE_v6_routes <id> <slot> <vrf> <ipv6prefix> <reason> <time> ] ] ]

Syntax Description

show

show

forwarding

Display Forwarding Information

proactive-cc

Proactive Consistency Checker

inconsistencies

Display latest CC run inconsistencies

all

(Optional) Display all previous CC run's inconsistencies

__readonly__

(Optional)

cc_status

(Optional) proactive cc status

TABLE_v4adj_hdr

(Optional) Table v4 adjacency header

incons_v4_adjs

(Optional) Inconsistent Adjacency header

TABLE_v4_adjs

(Optional) Table for v4 Adjacency

id

(Optional) Serial number

slot

(Optional) Slot number

vrf

(Optional) Vrf name

ipaddr

(Optional) Adjacency prefix

intf

(Optional) Interface

reason

(Optional) Inconsistency reason

time

(Optional) Timestamp

TABLE_v4route_hdr

(Optional) Table v4 route header

incons_v4_routes

(Optional) Inconsistent Route Header

TABLE_v4_routes

(Optional) Table for v4 routes

id

(Optional) Serial number

slot

(Optional) Slot number

vrf

(Optional) Vrf name

ipprefix

(Optional) Route Prefix

reason

(Optional) Inconsistency reason

time

(Optional) Timestamp

TABLE_v6adj_hdr

(Optional) Table v6 adjacency header

incons_v6_adjs

(Optional) Inconsistent v6 Adjacency header

TABLE_v6_adjs

(Optional) Table for v6 Adjacency

id

(Optional) Serial Number

slot

(Optional) Slot Number

vrf

(Optional) Vrf name

intf

(Optional) Interface

reason

(Optional) Inconsistency reason

time

(Optional) Timestamp

TABLE_v6route_hdr

(Optional) Table v6 Route header

incons_v6_routes

(Optional) Inconsistent route header

TABLE_v6_routes

(Optional) Table for v6 route

id

(Optional) Serial number

slot

(Optional) Slot number

vrf

(Optional) Vrf name

reason

(Optional) Inconsistency reason

time

(Optional) Timestamp

Command Mode

  • /exec

show forwarding security group-tag

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } | table <table_id> | vlan <vlan_id> ] [ ipv4 ] security group-tag [ <addr> ] [ module <module> | vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } ] + [ __readonly__ TABLE_sgt_vrf { <tid> <pfx-count> [ TABLE_sgt_prefix [ <ipa> ] [ <tag> ] [ <tv> ] ] } ]

Syntax Description

show

forwarding

display fib information

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

table

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

table_id

(Optional) table number

vlan

(Optional) vlan

vlan_id

(Optional) vlan number

ipv4

(Optional) ipv4

security

display IP security information

group-tag

ip_address->security_group_tag

addr

(Optional) specific ip address

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

TABLE_sgt_vrf

(Optional) vrf table

tid

(Optional) table identifier

pfx-count

(Optional) total prefix count in VRF

TABLE_sgt_prefix

(Optional) all xml prefix entries

ipa

(Optional) ip address

tag

(Optional) security group tag

tv

(Optional) sgt valid

Command Mode

  • /exec

show forwarding security mac

show forwarding [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } | table <table_id> ] [ ipv4 ] security mac [ <addr> ] [ module <module> | vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } ] + [ __readonly__ TABLE_sec_vrf { <tid> <pfx-count> [ TABLE_sec_prefix <ipa> <mac> <p> <m> <v> <intf> ] } ]

Syntax Description

show

forwarding

display fib information

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

table

THIS KEYWORD OR VARIABLE IS NOT SUPPORTED

table_id

(Optional) table number

ipv4

(Optional) ipv4

security

display IP security information

mac

ip_address->mac_address

addr

(Optional) specific ip address

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

TABLE_sec_vrf

(Optional) security vrf table

tid

(Optional) table identifier

pfx-count

(Optional) total prefix count in VRF

TABLE_sec_prefix

(Optional) all xml security prefix entries

ipa

(Optional) ip address

mac

(Optional) mac address

m

(Optional) 1 => ip->mac binding

v

(Optional) 1 => ip->vlan binding

p

(Optional) 1 => ip->port binding

intf

(Optional) ip->port interface

Command Mode

  • /exec

show forwarding srv6 adjacency decap

show forwarding srv6 adjacency decap [ table <table_id> ] [ module <num> ] [ __readonly__ { TABLE_adj_decap <locator> <function> <behavior> <tableid> <bd> <is_drop> } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

adjacency

SRV6 adjacency

decap

Decapsulation adjacency

table

(Optional) display info per vpn-id

table_id

(Optional) table number

bd

(Optional) Bridge domain

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_adj_decap

(Optional) all SRV6 decap adjacencies

locator

(Optional) Locator or binding sid

function

(Optional) Function

behavior

(Optional) Behavior

tableid

(Optional) tabled number

is_drop

(Optional) Indicates if adjacency is a drop

Command Mode

  • /exec

show forwarding srv6 adjacency encap

show forwarding srv6 adjacency encap [ table <table_id> ] [ module <num> ] [ __readonly__ { TABLE_adj_encap <loc_bsid> <source_ip> <function> <tableid> <is_drop> <bsid> } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

adjacency

SRV6 adjacency

encap

Encapsulation adjacency

table

(Optional) display info per vpn-id

table_id

(Optional) table number

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_adj_encap

(Optional) all SRV6 encap adjacencies

loc_bsid

(Optional) Locator or binding sid

source_ip

(Optional) Source IPV6 address

function

(Optional) Function

tableid

(Optional) tabled number

is_drop

(Optional) Indicates if adjacency is a drop

bsid

(Optional) binding sid

Command Mode

  • /exec

show forwarding srv6 bsid-peer

show forwarding srv6 bsid-peer [ <bsid_value> ] [ <endpoint> ] [ module <num> ] [ __readonly__ { TABLE_bsid_peer <bsid> <endpoint> <type> <table_id> <peer-id> } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

bsid-peer

Binding SID identifier

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_bsid_peer

(Optional) BSID peer table

bsid

(Optional) Bsid value

endpoint

(Optional) Endpoint

type

(Optional) BSID type

table_id

(Optional) Table ID

peer-id

(Optional) Peer ID

Command Mode

  • /exec

show forwarding srv6 bsid

show forwarding srv6 bsid [ <bsid_value> ] [ module <num> ] [ __readonly__ { TABLE_bsid <bsid> <type> <table_id> <num_sids> <sid_list> <list_count> } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

bsid

Binding SID

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_bsid

(Optional) BSID table

table_id

(Optional) Table ID

type

(Optional) BSID type

num_sids

(Optional) Number of SID's in list

bsid

(Optional) Bsid value

sid_list

(Optional) SID in list

list_count

(Optional) Number of dependent peer objects

Command Mode

  • /exec

show forwarding srv6 ecmp

show forwarding srv6 ecmp [ vrf { <vrf-name> | <vrf-known-name> | <vrf-all> } | [ table <table_id> ] ] [ module <num> ] [ __readonly__ { TABLE_ecmp <num_paths> <table_id> { TABLE_adj <loc_bsid> <source_ip> <function> } } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

ecmp

SRV6 ecmp

vrf

(Optional) display info per VRF

vrf-name

(Optional) VRF name

vrf-known-name

(Optional) Known VRF name

vrf-all

(Optional) Display information for all VRFs

table

(Optional) display info per vpn-id

table_id

(Optional) table number

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_ecmp

(Optional) ecmp table

num_paths

(Optional) No of paths

table_id

(Optional) table number

TABLE_adj

(Optional) Adjacency table

loc_bsid

(Optional) Locator or binding sid

source_ip

(Optional) Source IPV6 address

function

(Optional) Function

Command Mode

  • /exec

show forwarding srv6 local-sid

show forwarding srv6 local-sid [ <sid_value> ] [ detail ] [ module <num> ] [ __readonly__ { TABLE_local_sid <locator> <source_ip> <function> <behavior> <sid> } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

local-sid

local segment identifier

detail

(Optional) Details about SID

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_local_sid

(Optional) Local SID info

locator

(Optional) Locator

source_ip

(Optional) Source IPV6 address

function

(Optional) function

behavior

(Optional) Behavior

sid

(Optional) Segment identifier

Command Mode

  • /exec

show forwarding srv6 peers

show forwarding srv6 peers [ module <num> ] [ __readonly__ { TABLE_peers <peer_id> <locator> <source_ip> <vobj_count> } ]

Syntax Description

show

show

forwarding

display fib information

srv6

Segment routing V6

peers

SRV6 peer

module

(Optional) Slot/module

num

(Optional) Slot/module number

__readonly__

(Optional)

TABLE_peers

(Optional) all SRV6 peers

peer_id

(Optional) peer_id

locator

(Optional) Locator

source_ip

(Optional) Source IPV6 address

vobj_count

(Optional) Number of VOBJs dependent on this peer

Command Mode

  • /exec

show forwarding trace

show forwarding trace [ clear ] [ module <module> ] [ __readonly__ <op> ]

Syntax Description

show

forwarding

display fib information

trace

display trace buffer

clear

(Optional) clear the trace buffer

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

op

(Optional) output

Command Mode

  • /exec

show forwarding trace profile

show forwarding trace profile

Syntax Description

show

forwarding

display fib information

trace

display trace buffer

profile

show the collection profiling information

Command Mode

  • /exec

show forwarding trace profile funcstats

show forwarding trace profile funcstats [ enable | disable ] [ module <module> ] [ __readonly__ <op> ]

Syntax Description

show

forwarding

display fib information

trace

display trace buffer

profile

show the collection profiling information

funcstats

function statistics

enable

(Optional) enable function statistics

disable

(Optional) disable function statistics

module

(Optional) slot

module

(Optional) slot number

__readonly__

(Optional)

op

(Optional) output

Command Mode

  • /exec

show frequency synchronization clock-interface brief

show frequency synchronization clock-interface brief [ __readonly__ [ TABLE_fsync <clock_name> <source_class> <clock_node> <clock_id> <clock_state> <assigned_for_selection> <ssm_support> <ssm_enabled> <loop_back> <squelched> <input_disabled> <output_disabled> <ql_rcv_option> <ql_rcv> <ql_use_option> <ql_use> <priority> <ql_snt_option> <ql_snt> <selected_source_class> <selected_source_ifh> <selected_source_clock_node> <selected_source_clock_id> <selected_source_clock_name> ] <fsync-end> ]

Syntax Description

show

Show running system information

frequency

Frequency Synchronization Manager

synchronization

Frequency Synchronization Manager

clock-interface

Display clock-interface information

brief

Displays all interfaces

__readonly__

(Optional) Read Only

TABLE_fsync

(Optional) fsync_mgr table

source_class

(Optional) class of the source

clock_node

(Optional) clock's node id

clock_id

(Optional) clock's id

clock_name

(Optional) clock name

clock_state

(Optional) clock state

assigned_for_selection

(Optional) whether assigned as selection input

ssm_support

(Optional) ssm support - enabled or disabled

ssm_enabled

(Optional) ssm enabled - enabled or disabled

loop_back

(Optional) loopback enabled or disabled

squelched

(Optional) output is squelched or not

input_disabled

(Optional) input disabled or enabled

output_disabled

(Optional) output disabled or enabled

ql_rcv_option

(Optional) ql rcv option

ql_rcv

(Optional) ql rcv

ql_use_option

(Optional) ql use option

ql_use

(Optional) ql use

priority

(Optional) priority of synce port

ql_snt_option

(Optional) ql snt option

ql_snt

(Optional) ql snt

selected_source_class

(Optional) selected source class type

selected_source_ifh

(Optional) selected source ifh

selected_source_clock_node

(Optional) selected source clock node

selected_source_clock_id

(Optional) selected source clock id

selected_source_clock_name

(Optional) selected sourced clock name

fsync-end

(Optional) End of table

Command Mode

  • /exec

show frequency synchronization clock-interface detail

show frequency synchronization clock-interface detail [ __readonly__ [ TABLE_fsync <clock_name> <source_class> <clock_node> <clock_id> <clock_state> <clock_type> <pd_down_reason> <selection_input> <wtr_time> <ssm_state> <ssm_support> <input_disabled> <input_damping_state> <input_damping_time> <cfgd_in_ql_min_option> <cfgd_in_ql_min> <cfgd_in_ql_max_option> <cfgd_in_ql_max> <cfgd_in_ql_exact_option> <cfgd_in_ql_exact> <effective_in_ql_option> <effective_in_ql> <priority> <tod_priority> <supp_freq> <supp_time> <loop_back> <output_disabled> <selected_source_class> <selected_source_ifh> <selected_source_clock_node> <selected_source_clock_id> <selected_source_clock_name> <selected_source_ql_option> <selected_source_ql> <cfgd_out_ql_min_option> <cfgd_out_ql_min> <cfgd_out_ql_max_option> <cfgd_out_ql_max> <cfgd_out_ql_exact_option> <cfgd_out_ql_exact> <effective_out_ql_option> <effective_out_ql> <squelched> <num_next_seln_points> <next_selection_points> + <current_clock_end> ] <fsync-end> ]

Syntax Description

show

Show running system information

frequency

Frequency Synchronization Manager

synchronization

Frequency Synchronization Manager

clock-interface

Display clock-interface information

detail

details

__readonly__

(Optional) Read Only

TABLE_fsync

(Optional) fsync_mgr table

source_class

(Optional) class of the source

clock_node

(Optional) clock's node id

clock_id

(Optional) clock's id

clock_name

(Optional) clock name

clock_state

(Optional) clock state

clock_type

(Optional) clock's type

pd_down_reason

(Optional) clock pd down reason

selection_input

(Optional) whether assigned as selection input

wtr_time

(Optional) wait to restore timer value

ssm_state

(Optional) ssm state - enabled or disabled

ssm_support

(Optional) ssm supprt

input_disabled

(Optional) input disabled or enabled

input_damping_state

(Optional) input dampiung state

input_damping_time

(Optional) input damping time

cfgd_in_ql_min_option

(Optional) cfg in min ql option

cfgd_in_ql_min

(Optional) cfg in min ql option

cfgd_in_ql_max_option

(Optional) cfg in max ql option

cfgd_in_ql_max

(Optional) cfg in max ql option

cfgd_in_ql_exact_option

(Optional) cfg in exact ql option

cfgd_in_ql_exact

(Optional) cfg in exact ql option

effective_in_ql_option

(Optional) cfg in ql option

effective_in_ql

(Optional) cfg in ql option

priority

(Optional) priority

tod_priority

(Optional) time of day priority

supp_freq

(Optional) supporting freq sync or time sync

supp_time

(Optional) supporting time sync

loop_back

(Optional) loopback enabled or disabled

output_disabled

(Optional) output disabled or enabled

selected_source_class

(Optional) selected source class type

selected_source_ifh

(Optional) selected source ifh

selected_source_clock_node

(Optional) selected source clock node

selected_source_clock_id

(Optional) selected source clock id

selected_source_clock_name

(Optional) selected sourced clock name

selected_source_ql_option

(Optional) selected source ql option

selected_source_ql

(Optional) effective out ql option

cfgd_out_ql_min_option

(Optional) cfg out min ql option

cfgd_out_ql_min

(Optional) cfg out min ql option

cfgd_out_ql_max_option

(Optional) cfg out max ql option

cfgd_out_ql_max

(Optional) cfg out max ql option

cfgd_out_ql_exact_option

(Optional) cfg out exact ql option

cfgd_out_ql_exact

(Optional) cfg out exact ql option

effective_out_ql_option

(Optional) effective out ql option

effective_out_ql

(Optional) effective out ql option

squelched

(Optional) output is squelched or not

num_next_seln_points

(Optional) num of next seln points

next_selection_points

(Optional) next selection points

current_clock_end

(Optional) cuurent clock end

fsync-end

(Optional) End of table

Command Mode

  • /exec

show frequency synchronization configuration errors

show frequency synchronization configuration errors [ __readonly__ [ TABLE_fsync <fsync_src> <enable_err> <input_min_err> <input_exact_err> <input_max_err> <output_min_err> <output_exact_err> <output_max_err> <ext_ql_input_min_err> <ext_ql_input_exact_err> <ext_ql_input_max_err> <ext_ql_output_min_err> <ext_ql_output_exact_err> <ext_ql_output_max_err> <input_output_mismatch> <input_min_ql_option> <input_min_ql> <input_exact_ql_option> <input_exact_ql> <input_max_ql_option> <input_max_ql> <output_min_ql_option> <output_min_ql> <output_exact_ql_option> <output_exact_ql> <output_max_ql_option> <output_max_ql> <cmd_src_index> ] <fsync-end> ]

Syntax Description

show

Show running system information

frequency

Frequency Synchronization Manager

synchronization

Frequency Synchronization Manager

configuration

configuration

errors

errors

__readonly__

(Optional) Read Only

TABLE_fsync

(Optional) fsync_mgr table

fsync_src

(Optional) Interface Index

enable_err

(Optional) freq sync enable error

input_min_err

(Optional) Minimum input QL option config error

input_exact_err

(Optional) Exact input QL config error

input_max_err

(Optional) Maximum input QL option config error

output_min_err

(Optional) Minimum output QL option config error

output_exact_err

(Optional) Exact output QL option config error

output_max_err

(Optional) Maximum output QL option config error

ext_ql_input_min_err

(Optional) minimum input extended Ql config error

ext_ql_input_exact_err

(Optional) exact input extended Ql config error

ext_ql_input_max_err

(Optional) maximun input extended Ql config error

ext_ql_output_min_err

(Optional) min output extended ql config error

ext_ql_output_exact_err

(Optional) exact output extended ql config error

ext_ql_output_max_err

(Optional) max output extended ql config error

input_output_mismatch

(Optional) input/output mismatch error

input_min_ql_option

(Optional) input min ql option

input_min_ql

(Optional) configured min input ql

input_exact_ql_option

(Optional) input exact ql option

input_exact_ql

(Optional) configured exact input ql

input_max_ql_option

(Optional) input exact ql option

input_max_ql

(Optional) configured max input ql

output_min_ql_option

(Optional) output min ql option

output_min_ql

(Optional) configured min output ql

output_exact_ql_option

(Optional) output exact ql option

output_exact_ql

(Optional) configured exact output ql

output_max_ql_option

(Optional) output exact ql option

output_max_ql

(Optional) configured max output ql

cmd_src_index

(Optional) index for source array

fsync-end

(Optional) End of table

Command Mode

  • /exec

show frequency synchronization interface

show frequency synchronization interface <if0> [ __readonly__ <if_state> <selection_input> <wtr_time> <ssm_state> <esmc_peer_state> <esmc_peer_time_secs> <esmc_peer_time_nsecs> <last_ssm_time_secs> <last_ssm_time_nsecs> <peer_up_count> <peer_timeout_count> <esmc_infos_sent> <esmc_events_sent> <esmc_dnus_sent> <esmc_infos_rcvd> <esmc_events_rcvd> <esmc_dnus_rcvd> <esmc_malformed_rcvd> <esmc_rcvd_error> <input_damping_state> <input_damping_time> [ <last_rcvd_ql_option> ] [ <last_rcvd_ql> ] <cfgd_in_ql_min_option> <cfgd_in_ql_min> <cfgd_in_ql_max_option> <cfgd_in_ql_max> <cfgd_in_ql_exact_option> <cfgd_in_ql_exact> [ <effective_in_ql_option> ] [ <effective_in_ql> ] <priority> <tod_priority> [ <ql_data_rcvd_has_ext_data> ] [ <ql_data_rcvd_orig_clock_id> ] [ <ql_data_rcvd_synce_steps> ] [ <ql_data_rcvd_esynce_steps> ] [ <ql_data_rcvd_all_steps_synce> ] [ <ql_data_rcvd_chain_complete> ] <supp_freq> <supp_time> [ <selected_source_class> ] [ <selected_source_ifh> ] [ <selected_source_clock_node> ] [ <selected_source_clock_id> ] [ <selected_source_clock_name> ] [ <selected_source_ql_option> ] [ <selected_source_ql> ] <cfgd_out_ql_min_option> <cfgd_out_ql_min> <cfgd_out_ql_max_option> <cfgd_out_ql_max> <cfgd_out_ql_exact_option> <cfgd_out_ql_exact> [ <effective_out_ql_option> ] [ <effective_out_ql> ] [ <ql_data_to_send_has_ext_data> ] [ <ql_data_to_send_orig_clock_id> ] [ <ql_data_to_send_synce_steps> ] [ <ql_data_to_send_esynce_steps> ] [ <ql_data_to_send_all_steps_synce> ] [ <ql_data_to_send_chain_complete> ] <squelched> <num_next_seln_points> <next_selection_points> + ]

Syntax Description

show

Show running system information

frequency

Frequency Synchronization Manager

synchronization

Frequency Synchronization Manager

interface

Display interface information

if0

__readonly__

(Optional) Read Only

if_state

(Optional) interface state

selection_input

(Optional) whether assigned as selection input

wtr_time

(Optional) wait to restore timer value

ssm_state

(Optional) ssm state - enabled or disabled

esmc_peer_state

(Optional) esmc peer state

esmc_peer_time_secs

(Optional) peer up or down time recorded secs

esmc_peer_time_nsecs

(Optional) peer up or down time recorded nsecs

last_ssm_time_secs

(Optional) last ssm received time in secs

last_ssm_time_nsecs

(Optional) last ssm received time in nsecs

peer_up_count

(Optional) no of times peer went up

peer_timeout_count

(Optional) no of times peer timed out

esmc_infos_sent

(Optional) esmc infos sent

esmc_events_sent

(Optional) esmc events sent

esmc_dnus_sent

(Optional) esmc dnus sent

esmc_infos_rcvd

(Optional) esmc infos rcvd

esmc_events_rcvd

(Optional) esmc events rcvd

esmc_dnus_rcvd

(Optional) esmc dnus recvd

esmc_malformed_rcvd

(Optional) esmc malformed rcvd frames

esmc_rcvd_error

(Optional) esmc recv frame errors

input_damping_state

(Optional) input dampiung state

input_damping_time

(Optional) input damping time

last_rcvd_ql_option

(Optional) last ql rcv option

last_rcvd_ql

(Optional) last rcvd ql

cfgd_in_ql_min_option

(Optional) cfgd in ql min option

cfgd_in_ql_min

(Optional) cfg in ql min

cfgd_in_ql_max_option

(Optional) cfgd in ql mAX option

cfgd_in_ql_max

(Optional) cfgd in max ql

cfgd_in_ql_exact_option

(Optional) cfgd in ql exact option

cfgd_in_ql_exact

(Optional) cfgd in exact ql

effective_in_ql_option

(Optional) effe in ql option

effective_in_ql

(Optional) eff in ql

priority

(Optional) priority

tod_priority

(Optional) time of day priority

ql_data_rcvd_has_ext_data

(Optional) ql data rcvd extended data or not

ql_data_rcvd_synce_steps

(Optional) ql data rcvd synce steps

ql_data_rcvd_esynce_steps

(Optional) ql data rcvd extended synce steps

ql_data_rcvd_all_steps_synce

(Optional) ql data rcvd all steps synce or not

ql_data_rcvd_chain_complete

(Optional) ql data rcvd chain complete

supp_freq

(Optional) supporting freq sync or time sync

supp_time

(Optional) supporting time sync

selected_source_class

(Optional) selected source class type

selected_source_ifh

(Optional) selected source ifh

selected_source_clock_node

(Optional) selected source clock node

selected_source_clock_id

(Optional) selected source clock id

selected_source_clock_name

(Optional) selected sourced clock name

selected_source_ql_option

(Optional) selevted source ql option

selected_source_ql

(Optional) selected source ql

cfgd_out_ql_min_option

(Optional) cfgd out ql min option

cfgd_out_ql_min

(Optional) cfg out ql min

cfgd_out_ql_max_option

(Optional) cfgd out ql mAX option

cfgd_out_ql_max

(Optional) cfgd out max ql

cfgd_out_ql_exact_option

(Optional) cfgd out ql exact option

cfgd_out_ql_exact

(Optional) cfgd out exact ql

effective_out_ql_option

(Optional) eff out ql option

effective_out_ql

(Optional) effec out ql

ql_data_to_send_has_ext_data

(Optional) ql data to send extended data or not

ql_data_to_send_synce_steps

(Optional) ql data send synce steps

ql_data_to_send_esynce_steps

(Optional) ql data send extended synce steps

ql_data_to_send_all_steps_synce

(Optional) ql data send all steps synce or not

ql_data_to_send_chain_complete

(Optional) ql data send chain complete

squelched

(Optional) output is squelched or not

num_next_seln_points

(Optional) num of next seln points

next_selection_points

(Optional) next selection points

Command Mode

  • /exec

show frequency synchronization interface brief

show frequency synchronization interface brief [ __readonly__ [ TABLE_fsync <fsync_port> <if_state> <assigned_for_selection> <ssm_state> <esmc_peer_state> <squelched> [ <ql_rcv_option> ] [ <ql_rcv> ] [ <ql_use_option> ] [ <ql_use> ] <priority> [ <ql_snt_option> ] [ <ql_snt> ] [ <selected_source_class> ] [ <selected_source_ifh> ] [ <selected_source_clock_node> ] [ <selected_source_clock_id> ] [ <selected_source_clock_name> ] <port_end> ] <fsync-end> ]

Syntax Description

show

Show running system information

frequency

Frequency Synchronization Manager

synchronization

Frequency Synchronization Manager

interface

Display interface information

brief

Displays all interfaces

__readonly__

(Optional) Read Only

TABLE_fsync

(Optional) fsync_mgr table

fsync_port

(Optional) Interface Index

if_state

(Optional) interface state

assigned_for_selection

(Optional) whether assigned as selection input

ssm_state

(Optional) ssm state - enabled or disabled

esmc_peer_state

(Optional) esmc peer state

squelched

(Optional) output is squelched or not

ql_rcv_option

(Optional) ql rcv option

ql_rcv

(Optional) ql rcv

ql_use_option

(Optional) ql use option

ql_use

(Optional) ql use

priority

(Optional) priority of synce port

ql_snt_option

(Optional) ql snt option

ql_snt

(Optional) ql snt

selected_source_class

(Optional) selected source class type

selected_source_ifh

(Optional) selected source ifh

selected_source_clock_node

(Optional) selected source clock node

selected_source_clock_id

(Optional) selected source clock id

selected_source_clock_name

(Optional) selected sourced clock name

port_end

(Optional) end of current port

fsync-end

(Optional) End of table

Command Mode

  • /exec

show frequency synchronization selection

show frequency synchronization selection [ __readonly__ [ TABLE_sp <seln_pt> <num_inputs> <num_inputs_selected> <last_programmed_secs> <last_programmed_nsecs> <last_selection_secs> <last_selection_nsecs> [ <spa_selection_points> + ] [ <spa_selection_points_num> ] [ <node_selection_points> + ] [ <node_selection_points_num> ] [ <chassis_selection_points> + ] [ <chassis_selection_points_num> ] [ <router_selection_points> + ] [ <router_selection_points_num> ] <tod_sp> <local_line_output> <local_clock_output> <local_tod_output> <stream_table_start> [ TABLE_stream <output_id> <input> <last_sp> <ql> [ <tod_priority> ] <priority> <state> ] <stream-end> ] <sp-end> ]

Syntax Description

show

Show running system information

frequency

Frequency Synchronization Manager

synchronization

Frequency Synchronization Manager

selection

Display selection information

__readonly__

(Optional) Read Only

TABLE_sp

(Optional) fsync_mgr table

seln_pt

(Optional) selection points

num_inputs

(Optional) num of inputs

num_inputs_selected

(Optional) num of inputs

last_programmed_secs

(Optional) last programmed time:secs

last_programmed_nsecs

(Optional) last programmed time:nsecs

last_selection_secs

(Optional) last selection time:secs

last_selection_nsecs

(Optional) last selection time:nsecs

spa_selection_points

(Optional) SPA selection points

spa_selection_points_num

(Optional) Number of SPA selection points

node_selection_points

(Optional) Node selection points

node_selection_points_num

(Optional) Number of node selection points

chassis_selection_points

(Optional) chassis selection points

chassis_selection_points_num

(Optional) Number of chassis selection points

router_selection_points

(Optional) router selection points

router_selection_points_num

(Optional) Number of Router selection points

tod_sp

(Optional) Use Time of day selection point else freq sp

local_line_output

(Optional) used for local line output or not

local_clock_output

(Optional) used for local clock output or not

local_tod_output

(Optional) used for local time of day output or not

stream_table_start

(Optional) stream table start

TABLE_stream

(Optional) stream table

output_id

(Optional) output id of stream

input

(Optional) source input for the stream

last_sp

(Optional) last selection point string

ql

(Optional) QL of the selected source

tod_priority

(Optional) time of day priority

priority

(Optional) priority of source

state

(Optional) state of the stream

stream-end

(Optional) End of SP table

sp-end

(Optional) End of SP table

Command Mode

  • /exec

show fspf

show fspf

Syntax Description

show

Show running system information

Command Mode

  • /exec

show fspf database

show fspf database [ vsan <i0> [ [ domain <i1> ] [ detail ] ] ]

Syntax Description

show

Show running system information

database

Show FSPF link state database

vsan

(Optional) Enter VSAN

i0

(Optional) VSAN id

domain

(Optional) Show LSR of a domain

i1

(Optional) domain index

detail

(Optional) Gives detailed information on the LSR

Command Mode

  • /exec

show fspf interface

show fspf interface

Syntax Description

show

Show running system information

interface

Show FSPF related information about an interface

Command Mode

  • /exec

show fspf vsan

show fspf vsan <i0>

Syntax Description

show

Show running system information

vsan

Enter VSAN

i0

VSAN id

Command Mode

  • /exec

show fspf vsan interface

show fspf vsan <i0> interface [ <if0> ]

Syntax Description

show

Show running system information

vsan

Enter VSAN

i0

VSAN id

interface

Show FSPF related information about an interface

if0

(Optional) Show FSPF related information about an interface

Command Mode

  • /exec

show fte event

show fte event [ name ] [ { <eventname> } ] [ __readonly__ [ { TABLE_fte_event <event> [ <description> ] <use_count> [ { TABLE_fte_group <events> [ <buffer_drops> ] [ <fwd_drops> ] [ <acl_drops> ] [ <flow_count> ] [ <latency_threshold> ] [ <latency_unit> ] [ <latency_flow_count> ] } ] } ] ]

Syntax Description

show

Show running system information

fte

Show FTE information

event

Show Event Configuration

name

(Optional) Show the configuration for a specific FTE Event

eventname

(Optional) Specify a event

__readonly__

(Optional)

TABLE_fte_event

(Optional) Event Table

event

(Optional) Fte event

description

(Optional) Description of FTE event

use_count

(Optional) Use count of FTE event

TABLE_fte_group

(Optional)

events

(Optional) Drop or Latency type of events

buffer_drops

(Optional) Capture buffer-drops

fwd_drops

(Optional) Capture fwd-drops

acl_drops

(Optional) Capture acl-drops

flow_count

(Optional) Drop type flow count

latency_threshold

(Optional) Latency threshold value

latency_unit

(Optional) Unit for latency threshold measurement

latency_flow_count

(Optional) Latency type flow count

Command Mode

  • /exec

show fte exporter

show fte exporter [ name ] [ <exportername> ] [ __readonly__ <exporter> <description> <dest> <vrf> <vrf_id> <vrf_resolved> <dest_udp> <source_intf> <source_ip> <exporter-id> ]

Syntax Description

show

Show running system information

fte

Show FTE information

exporter

Show FTE Exporter Configuration

name

(Optional) Show a specific FTE Exporter

exportername

(Optional) Specify an exporter

__readonly__

(Optional)

exporter

(Optional)

description

(Optional)

dest

(Optional)

vrf

(Optional)

vrf_id

(Optional)

vrf_resolved

(Optional)

dest_udp

(Optional)

source_intf

(Optional)

source_ip

(Optional)

exporter-id

(Optional)

Command Mode

  • /exec

show fte monitor

show fte monitor [ name ] [ <monitorname> [ cache [ detailed ] ] ] [ __readonly__ <monitor> <use_count> <description> <record> <event> <exporter1> <exporter2> <bucket_id> <src_addr> <dest_addr> ]

Syntax Description

show

Show running system information

fte

Show FTE information

monitor

Show Monitor Configuration

name

(Optional) Show a specific FTE Monitor

monitorname

(Optional) Specify a monitor

cache

(Optional) Flow monitor cache contents

detailed

(Optional) Show the entire cache contents

__readonly__

(Optional)

monitor

(Optional)

use_count

(Optional)

description

(Optional)

record

(Optional)

event

(Optional)

exporter1

(Optional)

exporter2

(Optional)

bucket_id

(Optional)

src_addr

(Optional)

dest_addr

(Optional)

Command Mode

  • /exec

show fte record

show fte record [ name ] [ { <recordname> } | { fte-original } | { fte { protocol-port | layer2-switched { input } | { ipv4 | ipv6 | l2 } { original-input } } } ] [ __readonly__ [ { TABLE_fte_record <record> [ <description> ] <use_count> [ <match_ipv4_params> + ] [ <match_ipv6_params> + ] [ <match_datalink_params> + ] } ] ]

Syntax Description

show

Show running system information

fte

Show FTE information

record

Show Record Configuration

name

(Optional) Show the configuration for a specific FTE Record

recordname

(Optional) Specify a record

fte-original

(Optional) Traditional IPv4 input FTE with origin ASs

fte

(Optional) Traditional FTE collection schemes

ipv4

(Optional) IPv4 collection schemes

ipv6

(Optional) IPv6 collection schemes

l2

(Optional) L2 collection schemes

layer2-switched

(Optional) Layer2-Switched collection schemes

original-input

(Optional) Input FTE

input

(Optional) Input FTE

protocol-port

(Optional) Protocol and Ports aggregation scheme

__readonly__

(Optional)

TABLE_fte_record

(Optional) Record Table

record

(Optional) FTE Record

description

(Optional) Description for FTE description

use_count

(Optional) Use count for FTE record

match_ipv4_params

(Optional) Match IPv4 parameters under record

match_ipv6_params

(Optional) Match IPv6 parameters under record

match_datalink_params

(Optional) Match datalink parameters under record

Command Mode

  • /exec