Table Of Contents
Power Management and Environmental Monitoring
Understanding How Power Management Works
Enabling or Disabling Power Redundancy
Using the CLI to Power Modules Off and On
Using the CLI to View System Power Status
Using the CLI to Power Cycle Modules
Determining System Power Requirements
Understanding How Environmental Monitoring Works
Using CLI Commands to Monitor System Environmental Status
Understanding LED Environmental Indications
Power Management and Environmental Monitoring
This chapter describes the power management and environmental monitoring features in the Catalyst 6500 series switches.
Note
For complete syntax and usage information for the commands used in this chapter, refer to the Catalyst 6500 Series Switch Cisco IOS Command Reference publication.
This chapter consists of these sections:
•
Understanding How Power Management Works
•
Understanding How Environmental Monitoring Works
Understanding How Power Management Works
These sections describe power management in the Catalyst 6500 series switches:
•
Enabling or Disabling Power Redundancy
•
Using the CLI to Power Modules Off and On
•
Using the CLI to View System Power Status
•
Using the CLI to Power Cycle Modules
•
Determining System Power Requirements
Note
In systems with redundant power supplies, both power supplies must be of the same wattage. The Catalyst 6500 series switches allow you to mix AC-input and DC-input power supplies in the same chassis. For detailed information on supported power supply configurations, refer to the Catalyst 6500 Series Switch Installation Guide.
The modules have different power requirements, and certain configurations require more power than a single power supply can provide. Although the power management feature allows you to power all installed modules with two power supplies, redundancy is not supported in this configuration. Redundant and nonredundant power configurations are discussed in the following sections.
To determine the power requirements for your system, see the "Determining System Power Requirements" section.
Enabling or Disabling Power Redundancy
From global configuration mode, enter the power redundancy-mode combined | redundant commands to disable or enable redundancy (redundancy is enabled by default). You can change the configuration of the power supplies to redundant or nonredundant at any time.
Specifying the combined keyword disables redundancy. In a nonredundant configuration, the power available to the system is the combined power capability of both power supplies. The system powers up as many modules as the combined capacity allows. However, if one supply should fail and there is not enough power for all previously powered up modules, the system powers down those modules for which there is not enough power.
Specifying the redundant keyword enables redundancy. In a redundant configuration, the total power drawn from both supplies is at no time greater than the capability of one supply. If one supply malfunctions, the other supply can take over the entire system load. When you install and turn on two power supplies, each concurrently provides approximately half of the required power to the system. Load sharing and redundancy are enabled automatically; no software configuration is required.
Enter the show power command to view the current state of modules and the total power available for modules (see the "Using the CLI to View System Power Status" section).
Table 38-1 describes how the system responds to changes in the power supply configuration.
Table 38-1 Effects of Power Supply Configuration Changes
Configuration Change
|
Effect
|
Redundant to nonredundant
|
• System log and syslog messages are generated.
• System power is increased to the combined power capability of both supplies.
• Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
|
Nonredundant to redundant (both supplies must be of equal wattage)
|
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in the show power oper state field.
|
Equal wattage power supply is inserted with redundancy enabled
|
• System log and syslog messages are generated.
• System power equals the power capability of one supply.
• No change in module status since power capability is unchanged.
|
Equal wattage power supply is inserted with redundancy disabled
|
• System log and syslog messages are generated.
• System power is increased to the combined power capability of both supplies.
• Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
|
Higher or lower wattage power supply is inserted with redundancy enabled
|
• System log and syslog messages are generated.
• The system does not allow you to operate a power supply of different wattage even if the wattage is higher than the installed supply. The inserted supply shuts down.
|
Higher or lower wattage power supply is inserted with redundancy disabled
|
• System log and syslog messages are generated.
• System power is increased to the combined power capability of both supplies.
• Modules marked power-deny in the show power oper state field are brought up if there is sufficient power.
|
Power supply is removed with redundancy enabled
|
• System log and syslog messages are generated.
• No change in module status since power capability is unchanged.
|
Power supply is removed with redundancy disabled
|
• System log and syslog messages are generated.
• System power is decreased to the power capability of one supply.
• If there is not enough power for all previously powered-up modules, some modules are powered down and marked as power-deny in the show power oper state field.
|
System is booted with power supplies of different wattage installed and redundancy enabled
|
• System log and syslog messages are generated.
• The system does not allow you to have power supplies of different wattage installed in a redundant configuration. The lower wattage supply shuts down.
|
System is booted with power supplies of equal or different wattage installed and redundancy disabled
|
• System log and syslog messages are generated.
• System power equals the combined power capability of both supplies.
• The system powers up as many modules as the combined capacity allows.
|
Using the CLI to Power Modules Off and On
You can power down a module from the command-line interface (CLI) by entering the no power enable module slot command.
Note
When you enter the no power enable module slot command to power down a module, the module's configuration is not saved.
From global configuration mode, enter the power enable module slot command to turn the power on for a module that was previously powered down.
Using the CLI to View System Power Status
Enter the show power command to view the current power status of system components as follows:
system power redundancy mode = redundant
system power total = 1153.32 Watts (27.46 Amps @ 42V)
system power used = 397.74 Watts ( 9.47 Amps @ 42V)
system power available = 755.58 Watts (17.99 Amps @ 42V)
Power-Capacity PS-Fan Output Oper
PS Type Watts A @42V Status Status State
---- ------------------ ------- ------ ------ ------ -----
1 WS-CAC-2500W 1153.32 27.46 OK OK on
Pwr-Requested Pwr-Allocated Admin Oper
Slot Card-Type Watts A @42V Watts A @42V State State
---- ------------------ ------- ------ ------- ------ ----- -----
1 WS-X6K-SUP2-2GE 142.38 3.39 142.38 3.39 on on
5 WS-X6248-RJ-45 112.98 2.69 112.98 2.69 on on
Using the CLI to Power Cycle Modules
From global configuration mode, enter the power cycle module slot command to power cycle (reset) a module; the module powers off for 5 seconds and then powers on.
Determining System Power Requirements
System power requirements are dependent on the size of the power supply. You could have configuration limitations when using the 1000 W and 1300 W power supplies depending on the size of chassis and type of modules installed. For information about power consumption, refer to the Release Notes for the Catalyst 6000 Family Switches and Cisco 7600 Internet Router for Cisco IOS publication at this URL:
http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/relnotes/index.htm
Understanding How Environmental Monitoring Works
Environmental monitoring of chassis components provides early warning indications of possible component failure to ensure safe and reliable system operation and avoid network interruptions. This section describes the monitoring of these critical system components, enabling you to identify and rapidly correct hardware-related problems in your system.
Using CLI Commands to Monitor System Environmental Status
Enter the show environment [alarm | status | temperature] command to display system status information. The keywords display the following:
•
alarm—Displays environmental alarms
–
status—Displays alarm status
–
thresholds—Displays alarm thresholds
•
status—Displays field-replaceable unit (FRU) operational status and power and temperature information
•
temperature—Displays FRU temperature information
Understanding LED Environmental Indications
The LEDs can indicate two alarm types: major and minor. Major alarms indicate a critical problem that could lead to the system being shut down. Minor alarms are for informational purposes only, giving you notice of a problem that could turn critical if corrective action is not taken.
When the system has an alarm (major or minor), indicating an overtemperature condition, the alarm is not canceled or any action taken (such as module reset or shutdown) for 5 minutes. If the temperature falls 5°C (41°F) below the alarm threshold during this period, the alarm is canceled.
Table 38-2 lists the environmental indicators for the supervisor engine and switching modules.
Note
Refer to the Catalyst 6500 Series Switch Module Installation Guide for additional information on LEDs, including the supervisor engine SYSTEM LED.
Table 38-2 Environmental Monitoring for Supervisor Engine and Switching Modules
Component
|
Alarm Type
|
LED Indication
|
Action
|
Supervisor engine temperature sensor exceeds major threshold1
|
Major
|
STATUS2 LED red3
|
Syslog message and SNMP trap generated.
If redundancy, system switches to redundant supervisor engine and the active supervisor engine shuts down.
If there is no redundancy and the overtemperature condition is not corrected, the system shuts down after 5 minutes.
|
Supervisor engine temperature sensor exceeds minor threshold
|
Minor
|
STATUS LED orange
|
Syslog message and SNMP trap generated.
Monitor the condition.
|
Redundant supervisor engine temperature sensor exceeds major or minor threshold
|
Major
Minor
|
STATUS LED red
STATUS LED orange
|
Syslog message and SNMP trap generated.
If major alarm and the overtemperature condition is not corrected, the system shuts down after 5 minutes.
If minor alarm, monitor the condition.
|
Switching module temperature sensor exceeds major threshold
|
Major
|
STATUS LED red
|
Syslog message and SNMP trap generated.
Power down the module4 .
|
Switching module temperature sensor exceeds minor threshold
|
Minor
|
STATUS LED orange
|
Syslog message and SNMP trap generated.
Monitor the condition.
|