The Cisco 12016, Cisco 12416, and Cisco 12816 Router original series and enhanced series specifications are presented in four tables:
•
Table A-1, "Physical Specifications for Cisco 12000 Series Routers"
•
Table A-2, "AC Electrical Specifications"
•
Table A-3, "DC Electrical Specifications"
•
Table A-4, "Environmental Specifications"
Table A-2 AC Electrical Specifications
Description ValuePower
•
Standard subsystem (3 power supplies—original series)
•
Optional subsystem (4 power supplies—original series)
•
Standard subsystem (3 power supplies—enhanced series)
•
Optional subsystem (4 power supplies—enhanced series)
4000 W maximum (for 3 AC-input power supplies—N+1 redundancy)
4000 W maximum (for 4 AC-input power supplies—N+2 redundancy)
4800 W maximum (for 3 AC-input power supplies—N+1 redundancy)
4800 W maximum (for 4 AC-input power supplies—N+2 redundancy)
Rated input voltage1
200 to 240 VAC nominal (range: 180 to 264 VAC)
Rated input line frequency1
50 to 60 Hz nominal (range: 47 to 63 Hz)
Input current rating1
13 A maximum @ 200 to 240 VRMS
Source AC service requirement1
20 A North America; 16 A international
1 For each power supply module (three in the standard shelf; four in the optional shelf).
CautionTo ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.
Table A-3 DC Electrical Specifications
Description ValuePower
4800 W maximum
Rated input voltage1
-48 VDC nominal in North America
-60 VDC nominal in the European Community
(range: -40.5 to -72 VDC (-75 VDC FOR 5mS))-40 VDC to -72 VDC steady-state input voltage
Input current rating
60A maximum @ 40.5 VDC
Source DC service requirement
Sufficient to supply the rated input current. Local codes apply.
1 For each PEM.
1 To ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.
Table A-4 Environmental Specifications
Description ValueTemperature
Operating: 32° to 104°F (0° to 40°C)
Nonoperating: -4° to 149°F (-20° to 65°C)
Humidity
Operating: 10 to 90% noncondensing
Nonoperating: 5 to 95% noncondensing
Altitude
Operating: 0 to 10,000 ft (0 to 3,000 m)
Nonoperating: 0 to 15,000 ft (0 to 4,570 m)
Heat dissipation
11,602 BTU/hr maximum (original series)
16,378 BTU/hr maximum (enhanced series)
Acoustic noise
70 dBa maximum
Shock
Operating (halfsine): 21 in./sec (0.53 m/sec)
Nonoperating (trapezoidal pulse): 20G1 , 52 in./sec (1.32 m/sec)
Vibration
Operating: 0.35 Grms2 from 3 to 500 Hz
Nonoperating: 1.0 Grms from 3 to 500 Hz
1 G is a value of acceleration, where 1G equals 32.17 ft/sec2 (9.81 m/sec2).
2 Grms is the root mean square value of acceleration.
Compliance and Safety Information
The Cisco 12016, Cisco 2416 and Cisco 12816 routers are designed to meet the regulatory compliance and safety approval requirements. Refer to the Regulatory Compliance and Safety Information for the Cisco 12000 Series Router (Document Number 78-4347-xx) if you require additional compliance information (see "Cisco Technical Support & Documentation Website" section on page -xx for site information).