Table Of Contents
Technical Specifications
This appendix lists the Cisco 12010, Cisco 12410 and Cisco 12810 router specifications.
Router Specifications
The Cisco 12010, Cisco 12410, and Cisco 12810 series routers specifications are presented in four tables:
•
Table A-1, "Physical Specifications"
•
Table A-2, "AC Electrical Specifications"
•
Table A-3, "DC Electrical Specifications"
•
Table A-4, "Environmental Specifications"
Table A-2 AC Electrical Specifications
Description ValuePower
2791 VA (volt-amps) per AC power supply
(2 AC power supplies per system)—original series3000 VA (volt-amps) per AC power supply
(2 AC power supplies per system)—original seriesRated input voltage1
200-240 VAC nominal (range: 180 to 264 VAC)
220-240 VAC (UK)Rated input line frequency1
50/60 Hz nominal (range: 47 to 63 Hz)
50/60 Hz UKInput current rating1
15 A maximum @ 200 VAC
13 A maximum @220 to 240 VRMS (UK)Source AC service requirement1
20 A North America; 16 A international; 13 A UK
Heat dissipation
(total maximum)2800 W@9,544 BTU/hour
Redundancy
2 AC power supply modules required for 2N redundancy
1 For each AC power supply module.
CautionTo ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.
Table A-3 DC Electrical Specifications
Description ValuePower
2400 W per DC power entry module (original series)
2800 W per DC power entry module (enhanced series)Rated input voltage1
-48 VDC nominal in North America
-60 VDC nominal in the European Community
(range: -40.5 to -72 VDC (-75 VDC FOR 5mS))-40 VDC to -72 VDC steady-state input voltage
Input current rating1
60 A maximum (1x)—Original series
40 A maximum (2x)—Enhanced series
Source DC service requirement1
Sufficient to supply the rated input current. Local codes apply.
Redundancy
2 DC power entry modules required for 2N redundancy
1 For each DC power entry module.
CautionTo ensure that the chassis configuration complies with the required power budgets, use the on-line power calculator. Failure to properly verify the configuration may result in an unpredictable state if one of the power units fails. Contact your local sales representative for assistance.
Table A-4 Environmental Specifications
Description ValueTemperature
Operating: 32° to 104°F (0° to 40°C)
Nonoperating: -4° to 149°F (-20° to 65°C)
Humidity
Operating: 10 to 85% noncondensing
Nonoperating: 5 to 95% noncondensing
Altitude
Operating: 0 to 10,000 ft (0 to 3,000 m)
Nonoperating: 0 to 15,000 ft (0 to 4,570 m)
Heat dissipation
8,296 BTU/hr maximum (original series)
9,554 BTU/hr maximum (enhanced series)
Acoustic noise
70 dBa maximum
Shock
Operating (halfsine): 21 in/sec (0.53 m/sec)
Nonoperating (trapezoidal pulse): 20 G1 , 52 in/sec (1.32 m/sec)
Vibration
Operating: 0.35 Grms2 from 3 to 500 Hz
Nonoperating: 1.0 Grms from3 to 500 Hz
1 G is a value of acceleration, where 1G equals 32.17 ft/sec2 (9.81 m/sec2).
2 Grms is the root mean square value of acceleration.