Embedded Event Manager Configuration Guide, Cisco IOS XE Release 3SE (Catalyst 3850 Switches)
|
||||||||||||||||||||||
EEM 3.2 Utility Tcl Command Extensions
![]() |
|||||||||||||||||||||||
|
Contents EEM Utility Tcl Command ExtensionsLast Updated: December 29, 2012
The following conventions are used for the syntax documented on the Tcl command extension pages: [type ?]
priority low|normal|high
appl_readReads Embedded Event Manager (EEM) application volatile data. This Tcl command extension provides support for reading EEM application volatile data. EEM application volatile data can be published by a Cisco software process that uses the EEM application publish API. EEM application volatile data cannot be published by an EEM policy.
Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 7) FH_ENOSUCHKEY (could not find key) This error means that the application event detector info key or other ID was not found. (_cerr_sub_err = 9) FH_EMEMORY (insufficient memory for request) This error means that an internal EEM request for memory failed. appl_reqinfoRetrieves previously saved information from the Embedded Event Manager (EEM). This Tcl command extension provides support for retrieving information from EEM that has been previously saved with a unique key, which must be specified in order to retrieve the information. Note that retrieving the information deletes it from EEM. It must be resaved if it is to be retrieved again. Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 7) FH_ENOSUCHKEY (could not find key) This error means that the application event detector info key or other ID was not found. appl_setinfoSaves information in the Embedded Event Manager (EEM). This Tcl command extension provides support for saving information in the Embedded Event Manager that can be retrieved later by the same policy or by another policy. A unique key must be specified. This key allows the information to be retrieved later. Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 8) FH_EDUPLICATEKEY (duplicate appl info key) This error means that the application event detector info key or other ID was a duplicate. (_cerr_sub_err = 9) FH_EMEMORY (insufficient memory for request) This error means that an internal EEM request for memory failed. (_cerr_sub_err = 34) FH_EMAXLEN (maximum length exceeded) This error means that the object length or number exceeded the maximum. (_cerr_sub_err = 43) FH_EBADLENGTH (bad API length) This error means that the API message length was invalid. counter_modifyArgumentsSet _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 11) FH_ENOSUCHESID (unknown event specification ID) This error means that the event specification ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null) This error means that an internal EEM event detector pointer was null when it should have contained a value. (_cerr_sub_err = 30) FH_ECTBADOPER (bad counter threshold operator) This error means that the counter event detector set or modify operator was invalid. descriptionSample UsageThe description statement is entered by the author of the policy. It can appear before or after any event registration statement in Tcl. The policy can have only one description.
The following example shows how a brief description is provided for the event_register_syslog policy:
::cisco::eem::description "This Tcl command looks for the word count in syslog messages."
::cisco::eem::event_register_syslog tag 1 ...
::cisco::eem::event_register_snmp_object tag 2 ...
::cisco::eem::trigger
::cisco::eem::correlate event 1 and event 2
::cisco::eem::attribute tag 1 occurs 1
::cisco::eem::attribute tag 2 occurs 1
fts_get_stampregister_counterRegisters a counter and returns a counter event ID. This Tcl command extension is used by a counter publisher to perform this registration before using the event ID to manipulate the counter. Result Stringevent_id %d event_spec_id %d Where event_id is the counter event ID for the specified counter; it can be used to manipulate the counter by the unregister_counter or counter_modify Tcl command extensions. The event_spec_id argument is the event specification ID for the specified counter. Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 4) FH_EINITONCE (Init() is not yet done, or done twice.) This error means that the request to register the specific event was made before the EEM event detector had completed its initialization. (_cerr_sub_err = 6) FH_EBADEVENTTYPE (unknown EEM event type) This error means that the event type specified in the internal event specification was invalid. (_cerr_sub_err = 9) FH_EMEMORY (insufficient memory for request) This error means that an internal EEM request for memory failed. (_cerr_sub_err = 10) FH_ECORRUPT (internal EEM API context is corrupt) This error means that the internal EEM API context structure is corrupt. (_cerr_sub_err = 11) FH_ENOSUCHESID (unknown event specification ID) This error means that the event specification ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 12) FH_ENOSUCHEID (unknown event ID) This error means that the event ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 16) FH_EBADFMPPTR (bad ptr to fh_p data structure) This error means that the context pointer that is used with each EEM API call is incorrect. (_cerr_sub_err = 17) FH_EBADADDRESS (bad API control block address) This error means that a control block address that was passed in the EEM API was incorrect. (_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null) This error means that an internal EEM event detector pointer was null when it should have contained a value. (_cerr_sub_err = 25) FH_ESUBSEXCEED (number of subscribers exceeded) This error means that the number of timer or counter subscribers exceeded the maximum. (_cerr_sub_err = 26) FH_ESUBSIDXINV (invalid subscriber index) This error means that the subscriber index was invalid. (_cerr_sub_err = 54) FH_EFDUNAVAIL (connection to event detector unavailable) This error means that the event detector was unavailable. (_cerr_sub_err = 56) FH_EFDCONNERR (event detector connection error) This error means that the EEM event detector that handles this request is not available. register_timerRegisters a timer and returns a timer event ID. This Tcl command extension is used by a timer publisher to perform this registration before using the event ID to manipulate the timer if it does not use the event_register_timer command extension to register as a publisher and subscriber. Result Stringevent_id %u Where event_id is the timer event ID for the specified timer (can be used to manipulate the timer by the timer_arm or timer_cancel command extensions). Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 4) FH_EINITONCE (Init() is not yet done, or done twice.) This error means that the request to register the specific event was made before the EEM event detector had completed its initialization. (_cerr_sub_err = 6) FH_EBADEVENTTYPE (unknown EEM event type) This error means that the event type specified in the internal event specification was invalid. (_cerr_sub_err = 9) FH_EMEMORY (insufficient memory for request) This error means that an internal EEM request for memory failed. (_cerr_sub_err = 10) FH_ECORRUPT (internal EEM API context is corrupt) This error means that the internal EEM API context structure is corrupt. (_cerr_sub_err = 11) FH_ENOSUCHESID (unknown event specification ID) This error means that the event specification ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 16) FH_EBADFMPPTR (bad ptr to fh_p data structure) This error means that the context pointer that is used with each EEM API call is incorrect. (_cerr_sub_err = 17) FH_EBADADDRESS (bad API control block address) This error means that a control block address that was passed in the EEM API was incorrect. (_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null) This error means that an internal EEM event detector pointer was null when it should have contained a value. (_cerr_sub_err = 25) FH_ESUBSEXCEED (number of subscribers exceeded) This error means that the number of timer or counter subscribers exceeded the maximum. (_cerr_sub_err = 26) FH_ESUBSIDXINV (invalid subscriber index) This error means that the subscriber index was invalid. (_cerr_sub_err = 54) FH_EFDUNAVAIL (connection to event detector unavailable) This error means that the event detector was unavailable. (_cerr_sub_err = 56) FH_EFDCONNERR (event detector connection error) This error means that the EEM event detector that handles this request is not available. timer_armArguments
Result Stringsec_remain %ld msec_remain %ld Where sec_remain and msec_remain are the remaining time before the next expiration of the timer.
Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 6) FH_EBADEVENTTYPE (unknown EEM event type) This error means that the event type specified in the internal event specification was invalid. (_cerr_sub_err = 9) FH_EMEMORY (insufficient memory for request) This error means that an internal EEM request for memory failed. (_cerr_sub_err = 11) FH_ENOSUCHESID (unknown event specification ID) This error means that the event specification ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 12) FH_ENOSUCHEID (unknown event ID) This error means that the event ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null) This error means that an internal EEM event detector pointer was null when it should have contained a value. (_cerr_sub_err = 27) FH_ETMDELAYZR (zero delay time) This error means that the time specified to arm a timer was zero. (_cerr_sub_err = 42) FH_ENOTREGISTERED (request for event spec that is unregistered) This error means that the event was not registered. (_cerr_sub_err = 54) FH_EFDUNAVAIL (connection to event detector unavailable) This error means that the event detector was unavailable. (_cerr_sub_err = 56) FH_EFDCONNERR (event detector connection error) This error means that the EEM event detector that handles this request is not available. timer_cancelResult Stringsec_remain %ld msec_remain %ld Where sec_remain and msec_remain are the remaining time before the next expiration of the timer.
Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 6) FH_EBADEVENTTYPE (unknown EEM event type) This error means that the event type specified in the internal event specification was invalid. (_cerr_sub_err = 7) FH_ENOSUCHKEY (could not find key) This error means that the application event detector info key or other ID was not found. (_cerr_sub_err = 11) FH_ENOSUCHESID (unknown event specification ID) This error means that the event specification ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 12) FH_ENOSUCHEID (unknown event ID) This error means that the event ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null) This error means that an internal EEM event detector pointer was null when it should have contained a value. (_cerr_sub_err = 54) FH_EFDUNAVAIL (connection to event detector unavailable) This error means that the event detector was unavailable. (_cerr_sub_err = 56) FH_EFDCONNERR (event detector connection error) This error means that the EEM event detector that handles this request is not available. unregister_counterUnregisters a counter. This Tcl command extension is used by a counter publisher to unregister a counter that was previously registered with the register_counter Tcl command extension. Arguments
Set _cerrnoYes (_cerr_sub_err = 2) FH_ESYSERR (generic/unknown error from OS/system) This error means that the operating system reported an error. The POSIX errno value that is reported with the error should be used to determine the cause of the operating system error. (_cerr_sub_err = 9) FH_EMEMORY (insufficient memory for request) This error means that an internal EEM request for memory failed. (_cerr_sub_err = 11) FH_ENOSUCHESID (unknown event specification ID) This error means that the event specification ID could not be matched when the event was being registered or that an event detector internal event structure is corrupt. (_cerr_sub_err = 22) FH_ENULLPTR (event detector internal error - ptr is null) This error means that an internal EEM event detector pointer was null when it should have contained a value. (_cerr_sub_err = 26) FH_ESUBSIDXINV (invalid subscriber index) This error means that the subscriber index was invalid. (_cerr_sub_err = 54) FH_EFDUNAVAIL (connection to event detector unavailable) This error means that the event detector was unavailable. (_cerr_sub_err = 56) FH_EFDCONNERR (event detector connection error) This error means that the EEM event detector that handles this request is not available. © 2012 Cisco Systems, Inc. All rights reserved.
|
||||||||||||||||||||||
|
|