Table Of Contents
A - B - C - D - E - F - H - I - J - L - M - N - O - P - R - S - T - U - V - W -
Index
A
activity command 5-4
alarms, power supply unit fan 6-1
Australia
E1 digital trunk requirements 1-10
LAN cable requirements 1-13
T1 digital trunk requirements 1-7
B
breakout boxes
mounting for T1PRI or E1 system 2-7
using two at one time 2-7
C
cables
crossover for RJ-48 connectors, requirement 1-4
custom, requirements for E1 and T1 PRI 1-10
DB9 serial, requirement 1-4
E1 or T1 PRI, connecting
with one MP-MA-16-PRI 2-19
with one MP-MA-16-PRI and one MP-MA-4-PRI 2-26
with one MP-MA-4-PRI 2-23
with two MP-MA-16-PRIs 2-27
with two MP-MA-4-PRIs 2-25
E1 telephony, shipped 2-2
IP LAN, shipped 2-2
IP telephony, connecting 2-28
LAN, connecting to Cisco Unified MeetingPlace 8100 series 2-11
LAN requirements 1-13
modem, connecting 2-36
power, connecting to Cisco Unified MeetingPlace 8100 series 2-11
SCSI, connecting to Cisco Unified MeetingPlace 8112 2-11
T1 CAS, connecting for Cisco Unified MeetingPlace 8112 2-13
T1 CAS telephony, shipped 2-2
T1 digital trunk requirements 1-6
T1 PRI telephony, shipped 2-2
telephony, connecting for E1/IP or T1 PRI/IP system 2-32
telephony, connecting for T1 CAS/IP system 2-35
Canada
LAN cable requirements 1-13
modem requirements 1-11
power requirements 1-6
T1 digital trunk requirements 1-7
wiring requirements for customer-supplied RJ-48 connectors 1-9
Cisco Unified MeetingPlace 8100 series
connecting LAN cable 2-11
connecting power cable 2-11
mounting, about 2-3
power requirements 1-5
Cisco Unified MeetingPlace 8106
environmental requirements 1-4
mounting in 19-inch EIA equipment rack 2-5
mounting in 19-inch frame-relay rack 2-3
Cisco Unified MeetingPlace 8112
connecting SCSI cable 2-11
connecting T1 CAS telephony cables 2-13
environmental requirements 1-5
mounting in 19- or 23-inch EIA equipment rack 2-6
mounting in 19- or 23-inch frame-relay rack 2-4
commands
activity 5-4
configdiskcap 6-3
down 4-2
hwconfig 6-2
net 7-1
ping 5-7, 7-1
restart 7-2
restart disable 4-2
restart enable 4-3
spanstat 5-3
update 4-2
update status 4-3
update trace 4-3
COM port, laptop parameters 3-2
conferencing
testing in nonrecorded meetings with ad hoc recording 5-6
testing in recorded meetings 5-6
configdiskcap command 6-3
configuring
HyperTerminal 3-3
laptop 3-2
connecting
E1 or T1 PRI telephony cables
with one MP-MA-16-PRI 2-19
with one MP-MA-16-PRI and one MP-MA-4-PRI 2-26
with one MP-MA-4-PRI 2-23
with two MP-MA-16-PRIs 2-27
with two MP-MA-4-PRIs 2-25
IP telephony cables 2-28
LAN cable to Cisco Unified MeetingPlace 8100 series 2-11
laptop to Cisco Unified MeetingPlace 3-1
modem 2-36
power cable to Cisco Unified MeetingPlace 8100 series 2-11
SCSI cable to Cisco Unified MeetingPlace 8112 2-11
T1 CAS telephony cables for Cisco Unified MeetingPlace 8112 2-13
telephony cables for E1/IP or T1 PRI/IP system 2-32
telephony cables for T1 CAS/IP system 2-35
contents of shipped boxes 2-1
crossover cable for RJ-48 connectors, requirement 1-4
custom cables, requirements for E1 and T1 PRI 1-10
D
DB9 serial cable, requirement 1-4
dial-up networking, setting up 3-4
disk capacity, monitoring 6-3
down command 4-2
E
E1
about telephony configurations for 2-15
connecting telephony cables
with one MP-MA-16-PRI 2-19
with one MP-MA-16-PRI and one MP-MA-4-PRI 2-26
with one MP-MA-4-PRI 2-23
with two MP-MA-16-PRIs 2-27
with two MP-MA-4-PRIs 2-25
mixed with IP configuration, about 2-31
mounting breakout box 2-7
testing
inbound calls by using circular hunting 5-3
inbound calls by using dialing sequence 5-4
outbound calls 5-4
with IP, connecting cables 2-32
E1 digital trunks
connection requirements 1-10
requirements 1-10
supported protocols 1-10
enabling server disk capacity monitoring 6-3
environmental requirements
Cisco Unified MeetingPlace 8106 1-4
Cisco Unified MeetingPlace 8112 1-5
European Union
E1 digital trunk requirements 1-10
modem requirements 1-12
power requirements 1-6
F
FCC registration 1-7
filter, replacing in power supply unit fan 6-1
H
hardware requirements 1-3
Hong Kong
LAN cable requirements 1-13
modem requirements 1-11
power requirements 1-6
T1 digital trunk requirements 1-7
wiring requirements for customer-supplied RJ-48 connectors 1-9
hwconfig command 6-2
HyperTerminal
logging session 3-3
setting up 3-3
I
India, wiring requirements for customer-supplied RJ-45 connectors 1-9
installation, about testing 5-2
installing modem 2-36
IP
LAN cable requirements 1-13
systems, about configurations for 2-28
telephony cables, connecting 2-28
J
Japan
LAN cable requirements 1-13
modem requirements 1-12
power requirements 1-6
T1 digital trunk requirements 1-7
L
LAN
cable requirements 1-13
port requirements 1-12
laptop
configuring 3-2
connecting to Cisco Unified MeetingPlace 3-1
logging HyperTerminal session 3-3
M
maintenance
enabling server disk capacity monitoring 6-3
replacing filter in power supply unit fan 6-1
mixed systems, about telephony configurations for 2-31
modem
installing and connecting 2-36
requirements 1-11
testing connection 3-4
monitoring, enabling server disk capacity 6-3
mounting
breakout box for T1PRI or E1 system 2-7
Cisco Unified MeetingPlace 8100 series, about 2-3
Cisco Unified MeetingPlace 8106 in 19-inch EIA equipment rack 2-5
Cisco Unified MeetingPlace 8106 in 19-inch frame-relay rack 2-3
Cisco Unified MeetingPlace 8112 in 19- or 23-inch EIA equipment rack 2-6
Cisco Unified MeetingPlace 8112 in 19- or 23-inch frame-relay rack 2-4
Multi Access Blades
configurations for E1 and T1 PRI systems, about 2-15
connecting E1 or T1 PRI telephony cables
with one MP-MA-16-PRI 2-19
with one MP-MA-16-PRI and one MP-MA-4-PRI 2-26
with one MP-MA-4-PRI 2-23
with two MP-MA-16-PRIs 2-27
with two MP-MA-4-PRIs 2-25
N
net command 7-1
network latency, testing 5-7
O
onsite upgrade, viewing for sample session without disk backup (reference) A-16
P
ping command 5-7, 7-1
ports, LAN requirements 1-12
powering up Audio Server system 5-1
power requirements for Cisco Unified MeetingPlace 8100 series 1-5
power supply unit, replacing fan filter 6-1
protocols
supported for E1 digital trunks 1-10
supported for T1digital trunks 1-7
R
racks
mounting
Cisco Unified MeetingPlace 8106 in 19-inch EIA equipment 2-5
Cisco Unified MeetingPlace 8106 in 19-inch frame-relay 2-3
Cisco Unified MeetingPlace 8112 in 19- or 23-inch EIA equipment 2-6
Cisco Unified MeetingPlace 8112 in 19- or 23-inch frame-relay 2-4
types supported 2-3
recordings
testing conferencing in meetings 5-6
testing conferencing in nonrecorded meetings with ad hoc recording 5-6
remote upgrade
session, viewing real-time status for (reference) A-3
session, viewing status for (reference) A-3
viewing for a sample session without disk backup (reference) A-1
replacing filter in power supply unit fan 6-1
requirements
cable, LAN 1-13
digital connection for E1 1-10
digital connection for T1 1-8
E1 digital trunks 1-10
environmental, Cisco Unified MeetingPlace 8106 1-4
environmental, Cisco Unified MeetingPlace 8112 1-5
hardware 1-3
LAN, for ports 1-12
modem 1-11
power for Cisco Unified MeetingPlace 8100 series 1-5
T1 digital trunk 1-6
TCP/UDP 1-12
tools for installation 1-4
wiring, for customer-supplied RJ-45 connectors (U.K., Singapore, India) 1-9
wiring, for customer-supplied RJ-48 connectors (U.S., Canada, Hong Kong) 1-9
restart command 7-2
restart disable command 4-2
restart enable command 4-3
RJ-45 connectors, wiring requirements (U.K., Singapore, India) 1-9
RJ-48 connectors, wiring requirements (U.S., Canada, Hong Kong) 1-9
S
safety warnings 1-2
scheduling, testing 5-5
setting up
dial-up networking 3-4
HyperTerminal 3-3
Singapore, wiring requirements for customer-supplied RJ-45 connectors 1-9
software, upgrading Audio Server to Release 5.4 4-1
spanstat command 5-3
starting Audio Server system 5-1
system
powering up Audio Server 5-1
troubleshooting connection to Audio Server 7-1
T
T1 CAS
mixed with IP configuration, about 2-31
testing
inbound calls by using circular hunting 5-3
inbound calls by using dialing sequence 5-4
outbound calls 5-4
with IP, connecting cables 2-35
T1 digital trunks
connection requirements 1-8
requirements 1-6
supported protocols 1-7
T1 PRI
about telephony configurations for 2-15
connecting telephony cables
with one MP-MA-16-PRI 2-19
with one MP-MA-16-PRI and one MP-MA-4-PRI 2-26
with one MP-MA-4-PRI 2-23
with two MP-MA-16-PRIs 2-27
with two MP-MA-4-PRIs 2-25
mixed with IP configuration, about 2-31
mounting breakout box 2-7
testing
inbound calls by using circular hunting 5-3
inbound calls by using dialing sequence 5-4
outbound calls 5-4
with IP, connecting cables 2-32
TCP port requirements 1-12
telephony configurations
for E1 and T1PRI systems, about 2-15
for IP systems, about 2-28
for mixed systems, about 2-31
troubleshooting 7-2
telnet to Cisco Unified MeetingPlace system 3-3
terminal emulation software, configuring 3-2
testing
conferencing in nonrecorded meetings with ad hoc recording 5-6
conferencing in recorded meetings 5-6
inbound calls for T1 CAS, T1 PRI, E1 telephony by using circular hunting 5-3, 5-4
installation or upgrade, about 5-2
modem connection 3-4
network latency 5-7
outbound calls for T1 CAS, T1 PRI, E1 telephony 5-4
scheduling 5-5
troubleshooting telephony configuration 7-2
Web Conferencing 5-6
threshold values, monitoring disk capacity 6-3
tools required for installation 1-4
troubleshooting
connection to Audio Server system 7-1
telephony configuration 7-2
U
U.K., wiring requirements for customer-supplied RJ-45 connectors 1-9
U.S.
LAN cable requirements 1-13
modem requirements 1-11
power requirements 1-6
T1 digital trunk requirements 1-7
wiring requirements for customer-supplied RJ-48 connectors 1-9
UDP port requirements 1-12
update command 4-2
update status command 4-3
update trace command 4-3
upgrade
onsite, viewing for sample session without disk backup (reference) A-16
remote, viewing for a sample session without disk backup (reference) A-1
session, viewing real-time status for remote (reference) A-3
status, viewing for a remote upgrade session (reference) A-3
testing, about 5-2
upgrading Audio Server software to Release 5.4 4-1
V
viewing
onsite upgrade for sample session without disk backup (reference) A-16
real-time status for remote upgrade session (reference) A-3
remote upgrade for sample session without disk backup (reference) A-1
upgrade status for remote upgrade session (reference) A-3
W
warnings, safety 1-2
Web Conferencing, testing 5-6
wiring requirements
for customer-supplied RJ-45 connectors (U.K., Singapore, India) 1-9
for customer-supplied RJ-48 connectors (U.S., Canada, Hong Kong) 1-9