switch# show interface fc1/1 transceiver details
fc1/1 sfp is present
Name is CISCO-ACCELINK
Manufacturer's part number is RTXM520-571-C99
Hardware revision is 1.0
Serial number is ACW27150L32
Nominal bit rate is 57800 Mb/s
Link length supported for 50/125um OM3 fiber is 70 m
FC Transmitter type is short wave laser w/o OFC (SN)
FC Transmitter supports short distance link length
Transmission medium is multimode laser with 50 um aperture (M5)
Supported speeds are - Min speed: 16000 Mb/s, Max speed: 64000 Mb/s
Cisco extended id is none (0x0)
Cisco vendor id is (0x1f)
Cisco part number is 10-3538-01
Cisco pid is DS-SFP-FC64G-SW
Cisco version id is V01
Firmware version is 1.1
No tx fault, no rx loss, in sync state, diagnostic monitoring type is 0x68
SFP Diagnostics Information:
----------------------------------------------------------------------------
Alarms Warnings
High Low High Low
----------------------------------------------------------------------------
Temperature 46.80 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.28 V 3.63 V 2.97 V 3.46 V 3.13 V
Current 7.30 mA 12.00 mA 3.00 mA 11.20 mA 3.60 mA
Tx Power -0.16 dBm 7.00 dBm -10.50 dBm 4.00 dBm -7.50 dBm
Rx Power 0.58 dBm 5.00 dBm -10.00 dBm 4.00 dBm -7.00 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning
switch#
switch# install transceiver bootflash:nxos-transceiver-firmware.mds.9.4.1a.bin module 3-7,12
Locking current install transceiver session
2024 Jan 15 04:10:38 Starting transceiver firmware upgrade image file /bootflash/nxos-transceiver-firmware.mds.9.4.1.bin
2024 Jan 15 04:10:38 Extracting transceiver firmware(s) from package
357+1 records in
357+1 records out
234649 bytes (235 kB) copied, 0.00379426 s, 61.8 MB/s
Version (CISCO-ACCELINK) : 1.1
Version (CISCO-FINISAR) : 1.1
Upgrading transceivers on module(s): [3, 6, 7, 12]
Collecting interface configuration and transceiver information, please wait.
Transceivers will be upgraded according to following table:
Interface Transceiver Type Running Version New Version Upg Required Reload Required
--------- ---------------- --------------- ----------- ------------ ------------
fc6/18 CISCO-ACCELINK 1.0 1.1 yes yes
fc7/3 CISCO-ACCELINK 1.0 1.1 yes yes
--------------------------------------------------------------------------------------------
Transceiver firmware upgrade is a disruptive operation and all interfaces, including those interfaces that do not need upgrading in the respective line card(s), will be shutdown during the process. This will take approximately 00 hrs 08 mins to complete.
Any module with transceivers upgraded will be reloaded after the upgrade is finished.
--------------------------------------------------------------------------------------------
Do you want to proceed (y/n)?[n]: y
Proceeding with upgrade. Do not attempt any operations on the line card(s) where transceiver modules are undergoing upgrade.
Upgrading transceiver firmware on interface fc6/18.
Firmware upgrade of transceiver on interface fc6/18 is successful.
Upgrading transceiver firmware on interface fc7/3.
Firmware upgrade of transceiver on interface fc7/3 is successful.
Bringing up the interfaces after the upgrade.
Transceiver firmware upgrade status is as follows:
Interface Transceiver Type Old Version Current Version Result
--------- ---------------- ----------- --------------- ----------------
fc6/18 CISCO-ACCELINK 1.0 1.1 Success
fc7/3 CISCO-ACCELINK 1.0 1.1 Success
Reloading module(s) [6, 7] to complete the upgrade process. Please check the module status using `show module` command.
2024 Jan 15 04:21:55 Transceiver firmware upgrade completed
switch#
switch# install transceiver nxos-transceiver-firmware.mds.9.4.1a.bin
Locking current install transceiver session
2024 Jan 15 02:27:10 Starting transceiver firmware upgrade image file /bootflash/nxos-transceiver-firmware.mds.9.4.1.bin
2024 Jan 15 02:27:10 Extracting transceiver firmware(s) from package
357+1 records in
357+1 records out
234660 bytes (235 kB) copied, 0.00289415 s, 81.1 MB/s
Version (CISCO-ACCELINK) : 1.1
Version (CISCO-FINISAR) : 1.1
Upgrading transceivers on module(s): [1, 8, 18]
Collecting interface configuration and transceiver information, please wait.
Transceivers will be upgraded according to following table:
Interface Transceiver Type Running Version New Version Upg Required Reload Required
--------- ---------------- --------------- ----------- ------------ ------------
fc1/1 CISCO-FINISAR 0.126 1.1 yes yes
fc1/15 CISCO-ACCELINK 0.188 1.1 yes yes
fc8/4 CISCO-ACCELINK 0.188 1.1 yes yes
fc18/31 CISCO-FINISAR 0.126 1.1 yes yes
--------------------------------------------------------------------------------------------
Transceiver firmware upgrade is a disruptive operation and all interfaces, including those interfaces that do not need upgrading in the respective line card(s), will be shutdown during the process. This will take approximately 00 hrs 15 mins to complete.
Any module with transceivers upgraded will be reloaded after the upgrade is finished.
--------------------------------------------------------------------------------------------
Do you want to proceed (y/n)?[n]: y
Proceeding with upgrade. Do not attempt any operations on the line card(s) where transceiver modules are undergoing upgrade.
Upgrading transceiver firmware on interface fc1/1.
Firmware upgrade of transceiver on interface fc1/1 is successful.
Upgrading transceiver firmware on interface fc1/15.
Firmware upgrade of transceiver on interface fc1/15 is successful.
Upgrading transceiver firmware on interface fc8/4.
Firmware upgrade of transceiver on interface fc8/4 is successful.
Upgrading transceiver firmware on interface fc18/31.
Firmware upgrade of transceiver on interface fc18/31 is successful.
Bringing up the interfaces after the upgrade.
Transceiver firmware upgrade status is as follows:
Interface Transceiver Type Old Version Current Version Result
--------- ---------------- ----------- --------------- ----------------
fc1/1 CISCO-FINISAR 0.126 1.1 Success
fc1/15 CISCO-ACCELINK 0.188 1.1 Success
fc8/4 CISCO-ACCELINK 0.188 1.1 Success
fc18/31 CISCO-FINISAR 0.126 1.1 Success
Reloading module(s) [1, 8, 18] to complete the upgrade process. Please check the module status using `show module` command.
2024 Jan 15 02:44:16 Transceiver firmware upgrade completed
switch#
ファブリック スイッチのトランシーバ ファームウェアの更新
switch# install transceiver bootflash:nxos-transceiver-firmware.mds.9.4.1a.bin
Locking current install transceiver session
2024 Jan 15 01:57:26 Starting transceiver firmware upgrade image file /bootflash/nxos-transceiver-firmware.mds.9.4.1a.bin
2024 Jan 15 01:57:26 Extracting transceiver firmware(s) from package
357+1 records in
357+1 records out
234649 bytes (235 kB, 229 KiB) copied, 0.00224521 s, 105 MB/s
Version (CISCO-ACCELINK) : 1.1
Version (CISCO-FINISAR) : 1.1
Upgrading transceivers on module(s): [1]
Collecting interface configuration and transceiver information, please wait.
Transceivers will be upgraded according to following table:
Interface Transceiver Type Running Version New Version Upg Required Reload Required
--------- ---------------- --------------- ----------- ------------ ------------
fc1/18 CISCO-ACCELINK 1.0 1.1 yes yes
fc1/19 CISCO-FINISAR 0.101 1.1 yes yes
--------------------------------------------------------------------------------------------
Transceiver firmware upgrade is a disruptive operation and all interfaces, including those interfaces that do not need upgrading in the switch, will be shutdown during the process. This will take approximately 00 hrs 04 mins to complete.
This switch will be reloaded after the upgrade is finished.
--------------------------------------------------------------------------------------------
Do you want to proceed (y/n)?[n]: y
Proceeding with upgrade. Do not attempt any operations on the switch where transceiver modules are undergoing upgrade.
Upgrading transceiver firmware on interface fc1/18.
Firmware upgrade of transceiver on interface fc1/18 is successful.
Upgrading transceiver firmware on interface fc1/19.
Firmware upgrade of transceiver on interface fc1/19 is successful.
Bringing up the interfaces after the upgrade.
Transceiver firmware upgrade status is as follows:
Interface Transceiver Type Old Version Current Version Result
--------- ---------------- ----------- --------------- ----------------
fc1/18 CISCO-ACCELINK 1.0 1.1 Success
fc1/19 CISCO-FINISAR 0.101 1.1 Success
Reloading this switch to complete the upgrade process
switch#
例:トランシーバ電源制御機能が有効になっている場合のトランシーバ ファームウェアのアップグレード。
switch# install transceiver bootflash:nxos-transceiver-firmware.mds.9.4.2.bin module 7
Locking current install transceiver session
2024 May 06 14:32:53 Starting transceiver firmware upgrade image file /bootflash/nxos-transceiver-firmware.mds.9.4.2.bin
2024 May 06 14:32:53 Extracting transceiver firmware(s) from package
613+1 records in
613+1 records out
402271 bytes (402 kB, 393 KiB) copied, 0.00298808 s, 135 MB/s
Version (CISCO-ACCELINK, DS-SFP-FC64G-SW) : 1.2
Version (CISCO-FINISAR, DS-SFP-FC64G-SW) : 1.1
Version (CISCO-INNOLIGHT, DS-SFP-FC64G-LW) : 0.24
Upgrading transceivers on module(s): [7]
Transceiver power-control is ON, which will be turned OFF to perform firmware upgrade.
Do you want to proceed (y/n)?[n]: y
Collecting interface configuration and transceiver information, please wait.
Transceivers will be upgraded according to following table:
Interface Transceiver Type Running Version New Version Upg Required Reload Required
--------- ---------------- --------------- ----------- ------------ ------------
fc7/1 CISCO-ACCELINK 1.1 1.2 yes yes
fc7/17 CISCO-INNOLIGHT 0.23 0.24 yes yes
--------------------------------------------------------------------------------------------
Transceiver firmware upgrade is a disruptive operation and all interfaces, including those interfaces that do not need
upgrading in the respective line card(s), will be shutdown during the process. This will take approximately 00 hrs 09
mins to complete.
Any module with transceivers upgraded will be reloaded after the upgrade is finished.
--------------------------------------------------------------------------------------------
Do you want to proceed (y/n)?[n]: y
Proceeding with upgrade. Do not attempt any operations on the line card(s) where transceiver modules are undergoing
upgrade.
Upgrading transceiver firmware on interface fc7/1.
Firmware upgrade of transceiver on interface fc7/1 is successful.
Upgrading transceiver firmware on interface fc7/17.
Firmware upgrade of transceiver on interface fc7/17 is successful.
Bringing up the interfaces after the upgrade.
Transceiver firmware upgrade status is as follows:
Interface Transceiver Type Old Version Current Version Result
--------- ---------------- ----------- --------------- ----------------
fc7/1 CISCO-ACCELINK 1.1 1.2 Success
fc7/17 CISCO-INNOLIGHT 0.23 0.24 Success
Reloading module(s) [7] to complete the upgrade process. Please check the module status using `show module` command.
switch# install transceiver bootflash:nxos-transceiver-firmware.mds.9.4.1a.bin
Already one active install transceiver session is in progress. Running parallel install transceiver session(s) are not allowed.
If you want to re-run install transceiver due to previously aborted session(if any), please run 'install transceiver clean' first to do clean up and try running install transceiver again.
switch#
switch# install transceiver clean
Warning: Running this command clears the lock on any ongoing upgrade. The original upgrade process is not stopped and a subsequent upgrade will then be allowed, making the upgrade process likely to fail and cause transceiver damage. It is advised to use the install transceiver clean command only after an upgrade fails or terminates.
If an upgrade is terminated, wait for a few minutes for any ongoing upgrade to complete before attempting again. The approximate time required to complete each transceiver install session is displayed in the banner text before any upgrade process starts.
--------------------------------------------------------------------------------------------
Transceiver firmware upgrade is a disruptive operation and all interfaces, including those interfaces that do not need upgrading in the respective line card(s), will be shutdown during the process. This will take approximately 00 hrs 15 mins to complete.
Any module with transceivers upgraded will be reloaded after the upgrade is finished.
--------------------------------------------------------------------------------------------