UCS Server BIOS Tokens

Server BIOS Tokens in Release 4.1(3h)

The platforms supported in this release 4.1(3h) are:

  • B200 M5

  • B480 M5

  • C220 M5

  • C240 M5

  • C240 SD M5

  • C480 M5

  • S3260 M5

  • C125 M5

  • C480 M5 ML

The following table lists the newly added BIOS token names, including the defaults and values for each supported M5 platform in this release. The BIOS tokens listed in the Server BIOS Tokens in Release 4.1(1a) , Server BIOS Tokens in Release 4.1(2), Server BIOS Tokens in Release 4.1(3a), and Server BIOS Tokens in Release 4.1(3e) table are also supported in this release.

Name

Default Value

M5 Server Supported Values

Platform

Dependencies

SHA-1 PCR Bank

Enabled

Enabled, Disabled

All M5 Servers

SHA-256 PCR Bank

Enabled

Enabled, Disabled

All M5 Servers

Server BIOS Tokens in Release 4.1(3e)

The platforms supported in this release 4.1(3e) are:

  • B200 M5

  • B480 M5

  • C220 M5

  • C240 M5

  • C240 SD M5

  • C480 M5

  • S3260 M5

  • C125 M5

  • C480 M5 ML

The following table lists the newly added BIOS token names, including the defaults and values for each supported M5 platform in this release. The BIOS tokens listed in the Server BIOS Tokens in Release 4.1(1a) , Server BIOS Tokens in Release 4.1(2), and Server BIOS Tokens in Release 4.1(3a) table are also supported in this release.

Name

Default Value

M5 Server Supported Values

Platform

Dependencies

Burst and Postponed Refresh

Disabled

Enabled, Disabled

All M5 Servers

Server BIOS Tokens in Release 4.1(3a)

The platforms supported in this release 4.1(3a) are:

  • B200 M5

  • B480 M5

  • C220 M5

  • C240 M5

  • C240 SD M5

  • C480 M5

  • S3260 M5

  • C125 M5

  • C480 M5 ML

The following table lists the newly added BIOS token names, including the defaults and values for each supported M5 platform in this release. The BIOS tokens listed in the Server BIOS Tokens in Release 4.1(1a) and Server BIOS Tokens in Release 4.1(2) table are also supported in this release.

Name

Default Value

M5 Server Supported Values

Platform

Dependencies

Memory Thermal Throttling Mode

Closed Loop Thermal Throttling (CLTT) with Platform Environment Control Interface (PECI)

Closed Loop Thermal Throttling (CLTT) with Platform Environment Control Interface (PECI), Disabled

All M5 Servers

Note

 

This token is not supported on C125 M5 servers.

Advanced Memory Test

Disabled

Enabled, Disabled

All M5 Servers

Note

 

This token is not supported on C125 M5 servers.

Transparent Secure Memory Encryption (TSME)

Auto

Enabled, Disabled, Auto

C125 M5 servers

Secure Encrypted Virtualization (SEV)

Auto

253 ASIDs, 509 ASIDs, Auto

C125 M5 servers

DRAM SW Thermal Throttling

Disabled

Enabled, Disabled

C125 M5 servers

Memory Refresh Rate

1x Refresh

1x Refresh, 2x Refresh

All M5 Servers

Panic and High Watermark

Low

High, Low

All M5 Servers

PCIe PLL SSC

Disabled

Auto, Disabled, ZeroPointFive

All M5 Servers

Configurable TDP Level

Normal

Normal, Level 1, Level 2

All M5 Servers

Uncore Frequency Scaling

Enabled

Enabled, Disabled

All M5 Servers

UPI Link Frequency Select

Auto

Auto, 9.6GT/s, 10.4GT/s

All M5 Servers

External SSC Enable

Disabled for blade and Cisco UCS S3260 M5 Storage servers

Enabled for rack servers (except for Cisco UCS S3260 M5 Storage servers)

Enabled, Disabled

All M5 Servers

CR QoS

Disabled

Recipe 1, Recipe 2, Recipe 3, Disabled

All M5 Servers

NVM Performance Setting

BW Optimized

BW Optimized, Latency Optimized, Balanced Profile

All M5 Servers

CR FastGo Config

Auto

Default, Option 1, Option 2, Option 3, Option 4, Option 5, Auto

All M5 Servers

Snoopy mode for 2LM

Disabled

Enabled, Disabled

All M5 Servers

Snoopy mode for AD

Disabled

Enabled, Disabled

All M5 Servers

Server BIOS Tokens in Release 4.1(2)

Cisco UCS Manager, Release 4.1(2) introduces the Cisco UCS C240 SD M5 Server to the list of supported platforms. The platforms supported in this release are:

  • B200 M5

  • B480 M5

  • C220 M5

  • C240 M5

  • C240 SD M5

  • C480 M5

  • S3260 M5

  • C125 M5

  • C480 M5 ML

The following table lists the newly added BIOS token names, including the defaults and values for each supported M5 platform in this release. The BIOS tokens listed in the Server BIOS Tokens in Release 4.1(1a) table are also supported in this release.

Name

Default Value

M5 Server Supported Values

Platform

Dependencies

Memory Refresh Rate

2x Refresh

1x Refresh, 2x Refresh

All M5 Servers

Panic and High Watermark

Low

High, Low

All M5 Servers

PCIe PLL SSC

Disabled

Auto, Disabled, ZeroPointFive

All M5 Servers

Configurable TDP Level

Normal

Normal, Level 1, Level 2

All M5 Servers

Uncore Frequency Scaling

Enabled

Enabled, Disabled

All M5 Servers

UPI Link Frequency Select

Auto

Auto, 9.6GT/s, 10.4GT/s

All M5 Servers

External SSC Enable

Disabled for blade and Cisco UCS S3260 M5 Storage servers

Enabled for rack servers (except for Cisco UCS S3260 M5 Storage servers)

Enabled, Disabled

All M5 Servers

CR QoS

Disabled

Recipe 1, Recipe 2, Recipe 3, Disabled

All M5 Servers

NVM Performance Setting

BW Optimized

BW Optimized, Latency Optimized, Balanced Profile

All M5 Servers

CR FastGo Config

Auto

Default, Option 1, Option 2, Option 3, Option 4, Option 5, Auto

All M5 Servers

Snoopy mode for 2LM

Disabled

Enabled, Disabled

All M5 Servers

Snoopy mode for AD

Disabled

Enabled, Disabled

All M5 Servers

Server BIOS Tokens in Release 4.1(1a)

The UCS M5 platforms supported in this release are:

  • B200 M5

  • B480 M5

  • C220 M5

  • C240 M5

  • C480 M5

  • S3260 M5

  • C125 M5

  • C480 M5 ML

The following table lists the BIOS token names, including the defaults and values for each supported M5 platform in this release.

Name

Default Value

M5 Server Supported Values

Platform

Dependencies

Legacy USB Support

Enabled

Disabled , Enabled, Auto

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

FRB-2 Timer

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

OS Boot Watchdog Timer Policy

Power Off

Power Off, Reset

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Applicable only when OS Boot Watchdog Timer is Enabled.

OS Boot Watchdog Timer Timeout

10 minutes

5 minutes, 10 minutes, 15 minutes, 20 minutes

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Applicable only when OS Boot Watchdog Timer is Enabled.

OS Boot Watchdog Timer

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Flow Control

None

None, RTS-CTS

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Applicable only when Console Redirection is COM 0.

Baud Rate

115.2k

9.6k, 19.2k, 38.4k, 57.6k, 115.2k

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Applicable only when Console Redirection is COM 0.

Terminal Type

VT100

PC-ANSI, VT100, VT100-PLUS, VT-UTF8

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Applicable only when Console Redirection is COM 0.

Console Redirection

Disabled

COM 0, COM 1, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Number of Retries

13

Infinite, 5, 13

B200 M5

B480 M5

C480 M5

Applicable only when Boot Option Retry is Enabled.

Cool Down Time (sec)

90

15, 45, 90

B200 M5

B480 M5

C480 M5

Applicable only when Boot Option Retry is Enabled.

Boot Option Retry

Disabled

Enabled, Disabled

B200 M5

B480 M5

C480 M5

Trusted Platform Module (TPM)

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Intel Virtualization Technology

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Intel VT for directed IO

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Intel Trusted Execution Technology Support

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Can be Enabled only when Trusted Platform Module (TPM) is Enabled.

Enabling Intel Trusted Execution Technology Support auto enables Intel VT for directed IO andIntel Virtualization Technology.

Local 2X Apic

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Enabling Local X2 Apic auto enables Intel VT for directed IO.

Intel VTD Coherency Support

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Intel VTD ATS support

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

UEFI Boot Mode

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

NUMA Optimized

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Select Memory RAS configuration

ADDDC Sparing

Mirror Mode 1LM, Partial Mirror mode 1LM, Maximum Performance, ADDDC Sparing

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Select PPR Type

Hard PPR

Hard PPR, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Memory Mapped IO Above 4GB

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Hardware Prefetcher

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Adjacent Cache Line Prefetcher

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

DCU Streamer Prefetch

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

DCU IP Prefetcher

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Processor C1E

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Processor C6 Report

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Execute Disable Bit

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Intel Turbo Boost Tech

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

P STATE Coordination

HW ALL

HW ALL, SW ALL, SW ANY

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Boot Performance Mode

Max Performance

Max Performance, Max Efficient, Set by Intel NM

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Enhanced Intel SpeedStep Tech

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Disabling Enhanced Intel SpeedStep Tech auto disables Intel Turbo Boost Tech.

Intel HyperThreading Tech

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

CPU Performance

Custom

Enterprise, HPC, High Throughput, Custom

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

If set as Enterprise then:

  • Hardware Prefetcher is Enabled

  • Adjacent Cache Line Prefetcher is Enabled

  • DCU Streamer Prefetch is Enabled

  • DCU IP Prefetcher is Enabled

If set as High Throughput then:
  • Hardware Prefetcher is Disabled

  • Adjacent Cache Line Prefetcher is Disabled

  • DCU Streamer Prefetch is Disabled

  • DCU IP Prefetcher is Enabled

If set as HPC then:
  • Hardware Prefetcher is Enabled

  • Adjacent Cache Line Prefetcher is Enabled

  • DCU Streamer Prefetch is Enabled

  • DCU IP Prefetcher is Enabled

CDN Control

Enabled

Enabled, Disabled

B480 M5B200 M5, , C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

By default, CDN Control is Disabled in the UCSM Manager. (It is Enabled by default in Standalone mode.)

Processor CMCI

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Adaptive Memory Training

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C480 M5 ML

OptionROM Launch Optimization

Enabled

Enabled, Disabled

All M5 Servers

BIOS Techlog Level

Minimum

Maximum, Normal, Minimum

All M5 Servers

All Onboard LOM

Enabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

If set as Disabled, then LOM Port 0 OptionROM and LOM Port 1 OptionROM are Disabled.

If set as Enabled, then LOM Port 0 OptionROM and LOM Port 1 OptionROM are Enabled.

VMD Enable

Disabled

Enabled, Disabled

C220 M5, C240 M5, B200 M5, B480 M5

PCIe RAS Support

Enabled

Enabled, Disabled

All M5 Servers

ACS Control SLOT-11

Enabled

Enabled, Disabled

C480 M5

ACS Control SLOT-12

Enabled

Enabled, Disabled

C480 M5

ACS Control SLOT-13

Enabled

Enabled, Disabled

C480 M5

ACS Control SLOT-14

Enabled

Enabled, Disabled

C480 M5

ACS Control GPU-1

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-2

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-3

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-4

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-5

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-6

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-7

Disabled

Enabled, Disabled

C480 M5

ACS Control GPU-8

Disabled

Enabled, Disabled

C480 M5

LOM Port 1 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5

C480 M5

LOM Port 2 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5

C480 M5

SBNVMe1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SBNVMe2 OptionROM

Enabled

Disabled, Enabled

S3260 M5

IOEMezz1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

IOENVMe1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

IOENVMe2 OptionROM

Enabled

Disabled, Enabled

S3260 M5

IOESlot1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

IOESlot2 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SBMezz1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SBMezz2 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SIOC1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SIOC2 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SIOCNvme1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SIOCNvme2 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SBLom1 OptionROM

Enabled

Disabled, Enabled

S3260 M5

SBNVMe1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SBNVMe2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SIOCNVMe1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SIOCNVMe2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SIOC1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SIOC2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SBMezz1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

SBMezz2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

IOESlot1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

IOESlot2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

IOEMezz1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

IOENVMe1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

IOENVMe2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

S3260 M5

PCIe Slot 1 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5

C480 M5

PCIe Slot 2 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5

C480 M5

PCIe Slot 3 OptionROM

Enabled

Disabled, Enabled

C240 M5

C480 M5

PCIe Slot 4 OptionROM

Enabled

Disabled, Enabled

C240 M5

C480 M5

PCIe Slot 5 OptionROM

Enabled

Disabled, Enabled

C240 M5

C480 M5

PCIe Slot 6 OptionROM

Enabled

Disabled, Enabled

C240 M5

C480 M5

PCIe Slot 7 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 8 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 9 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 10 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 11 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 12 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 13 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot 14 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot MLOM OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5

PCIe Slot MRAID OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5

PCIe Slot RAID OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N1 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N2 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N3 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N4 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N5 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N6 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N7 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N8 OptionROM

Enabled

Disabled, Enabled

C220 M5, C240 M5, C480 M5

PCIe Slot N9 OptionROM

Enabled

Disabled, Enabled

C220 M5, C480 M5

PCIe Slot N10 OptionROM

Enabled

Disabled, Enabled

C220 M5, C480 M5

PCIe Slot N11 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N12 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N13 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N14 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N15 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N16 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N17 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N18 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N19 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N20 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N21 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N22 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N23 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot N24 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot Rear NVMe1 OptionROM

Enabled

Disabled, Enabled

C240 M5, C480 M5

PCIe Slot Rear NVMe2 OptionROM

Enabled

Disabled, Enabled

C240 M5, C480 M5

PCIe Slot Rear NVMe3 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot Rear NVMe4 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot Rear NVMe5 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot Rear NVMe6 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot Rear NVMe7 OptionROM

Enabled

Disabled, Enabled

C480 M5

PCIe Slot Rear NVMe8 OptionROM

Enabled

Disabled, Enabled

C480 M5

MRAID Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C220 M5, C240 M5

RAID Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

MLOM Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C220 M5, C240 M5

PCIe Slot 1 Link Speed

Auto

Disabled, Auto, GEN1 , GEN2, GEN3

C220 M5, C240 M5

C480 M5

C125 M5

PCIe Slot 2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C220 M5, C240 M5

C480 M5

C125 M5

PCIe Slot 3 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C240 M5

C480 M5

C125 M5

PCIe Slot 4 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C240 M5

C480 M5

C125 M5

PCIe Slot 5 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C240 M5

C480 M5

C125 M5

PCIe Slot 6 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C240 M5

C480 M5

C125 M5

PCIe Slot 7 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

C125 M5

PCIe Slot 8 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

C125 M5

PCIe Slot 9 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

C125 M5

PCIe Slot 10 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

C125 M5

PCIe Slot 11 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

C125 M5

PCIe Slot 12 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C480 M5

C125 M5

Front NVME1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C220 M5, C240 M5

Front NVME2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C220 M5, C240 M5

Rear NVME1 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C240 M5

Rear NVME2 Link Speed

Auto

Disabled, Auto, GEN1, GEN2, GEN3

C240 M5

Power On Password

Disabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

C125 M5

P-SATA mode

For S3260 M5: AHCI

For all other servers: LSI SW RAID

AHCI, LSI SW RAID, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Processor Prefetch Config

Auto

Enabled, Disabled,Auto

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

VGA Priority

OnBoard

OnBoard, OffBoard, OnBoard VGA Disabled

C220 M5, C240 M5

Core Multi Processing

All

All, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

USB Port Front

Enabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

USB Port Rear

Enabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

USB Port KVM

Enabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

USB Port VMedia

Enabled

Enabled, Disabled

C480 M5

USB Port Internal

Enabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

USB Port SD Card

Enabled

Enabled, Disabled

C220 M5, C240 M5

C480 M5

Workload Configuration

IO Sensitive

Balanced, IO Sensitive

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

IMC Interleave

Auto

1-way Interleave, 2-way Interleave, Auto

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Sub NUMA Clustering

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

KTI Prefetch

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

XPT Prefetch

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Energy Performance Tuning

OS

OS, BIOS

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

If set as OS then Energy Performance is Balanced Performance.

If set as BIOS then, Energy Performance is Performance, Balanced Performance, Balanced Power, or Power.

Energy Performance

Balanced Performance

Performance, Balanced Performance, Balanced Power, Power

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Package C State Limit

C0 C1 State

No Limit, Auto, C0 C1 State, C2, C6 Non Retention, C6 Retention

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

LLC Prefetch

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

CPU Hardware Power Management

HWPM Native Mode

Disabled, HWPM Native Mode, HWPM OOB Mode, Native Mode with no Legacy

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

If set as HWPM OOB Mode then, ProcessorEppProfile is set as Performance, Balanced Performance, or Balanced Power, Power.

IPV6 PXE Support

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Energy Efficient Turbo

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Autonomous Core C-state

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

ProcessorEppProfile

Balanced Performance

Performance, Balanced Performance, Balanced Power, Power

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Patrol Scrub

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

Intel Speed Select

Base

Base, Option 1, Option 2

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5

BME DMA Mitigation

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

CDN Support for LOMs

Disabled

Enabled, Disabled

C480 M5

DCPMM Firmware Downgrade

Disabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Core Performance Boost

Auto

Auto, Disabled

C125 M5

Global C-state Control

Auto

Auto, Enabled, Disabled

C125 M5

L1 Stream HW Prefetcher

Auto

Auto, Enabled, Disabled

C125 M5

L2 Stream HW Prefetcher

Auto

Auto, Enabled, Disabled

C125 M5

AMD Memory Interleaving

Auto

Auto, None,Channel, Die, Socket

C125 M5

AMD Memory Interleaving Size

Auto

Auto, 256 Bytes, 512 Bytes, 1 KB, 2 KB

C125 M5

Chipselect Interleaving

Auto

Auto, Disabled

C125 M5

Bank Group Swap

Auto

Auto, Enabled, Disabled

C125 M5

Determinism Slider

Auto

Auto, Power, Performance

C125 M5

IOMMU

Auto

Auto, Enabled, Disabled

C125 M5

Downcore control

Auto

Auto, TWO (1 + 1), TWO (2 + 0), THREE (3 + 0), FOUR (2 + 2), FOUR (4 + 0), SIX (3 + 3)

C125 M5

SMT Mode

Auto

Auto, Off

C125 M5

SVM Mode

Enabled

Enabled, Disabled

C125 M5

SMEE

Enabled

Enabled, Disabled

C125 M5

PCIe Slot GPU1 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU2 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU3 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU4 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU5 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU6 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU7 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

PCIe Slot GPU8 OptionROM

Enabled

Enabled, Disabled

C480 M5 ML

Slot 1 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 2 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 3 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 4 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 5 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 6 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 7 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 8 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 9 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 10 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 11 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 12 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 13 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Slot 14 state

Enabled

Enabled, Disabled, UEFI Only, Legacy Only

C480 M5 ML

Partial Memory Mirror Mode

Disabled

Percentage, Value in GB, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Partial Mirror percentage

0.00

0.00 - 50.00 with a step size of 0.01

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Partial Mirror1 Size in GB

0

0 - 65535 with a step size of 1

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Partial Mirror2 Size in GB

0

0 - 65535 with a step size of 1

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Partial Mirror3 Size in GB

0

0 - 65535 with a step size of 1

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Partial Mirror4 Size in GB

0

0 - 65535 with a step size of 1

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Memory Size Limit in GB

0

0 - 65535 with a step size of 1

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

Network Stack

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5

IPV4 PXE Support

Enabled

Enabled, Disabled

B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5