Legacy USB Support
|
Enabled
|
Disabled , Enabled, Auto
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
FRB-2 Timer
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
OS Boot Watchdog Timer Policy
|
Power Off
|
Power Off, Reset
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
Applicable only when OS Boot Watchdog Timer is Enabled.
|
OS Boot Watchdog Timer Timeout
|
10 minutes
|
5 minutes, 10 minutes, 15 minutes, 20 minutes
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
Applicable only when OS Boot Watchdog Timer is Enabled.
|
OS Boot Watchdog Timer
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
Flow Control
|
None
|
None, RTS-CTS
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
Applicable only when Console Redirection is COM 0.
|
Baud Rate
|
115.2k
|
9.6k, 19.2k, 38.4k, 57.6k, 115.2k
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
Applicable only when Console Redirection is COM 0.
|
Terminal Type
|
VT100
|
PC-ANSI, VT100, VT100-PLUS, VT-UTF8
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
Applicable only when Console Redirection is COM 0.
|
Console Redirection
|
Disabled
|
COM 0, COM 1, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
Number of Retries
|
13
|
Infinite, 5, 13
|
B200 M5
B480 M5
C480 M5
|
Applicable only when Boot Option Retry is Enabled.
|
Cool Down Time (sec)
|
90
|
15, 45, 90
|
B200 M5
B480 M5
C480 M5
|
Applicable only when Boot Option Retry is Enabled.
|
Boot Option Retry
|
Disabled
|
Enabled, Disabled
|
B200 M5
B480 M5
C480 M5
|
|
Trusted Platform Module (TPM)
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
Intel Virtualization Technology
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Intel VT for directed IO
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Intel Trusted Execution Technology Support
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
Can be Enabled only when Trusted Platform Module (TPM) is Enabled.
Enabling Intel Trusted Execution Technology Support auto enables Intel VT for directed IO andIntel Virtualization Technology.
|
Local 2X Apic
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
Enabling Local X2 Apic auto enables Intel VT for directed IO.
|
Intel VTD coherency support
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Intel VTD ATS support |
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
UEFI Boot Mode
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
NUMA optimized
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
SelectMemory RAS configuration
|
ADDDC Sparing
|
Mirror Mode 1LM, Mirroring, Maximum Performance, Lockstep, Sparing, ADDDC Sparing
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Memory mapped IO above 4GB
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Hardware Prefetcher
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Adjacent Cache Line Prefetcher
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
DCU Streamer Prefetch
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
DCU IP Prefetcher
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Processor C1E
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Processor C6 Report
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Execute Disable Bit
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Intel Turbo Boost Tech
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
EIST PSD Function
|
HW ALL
|
HW ALL, SW ALL, SW ANY
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Boot Performance Mode
|
Max Performance
|
Max Performance, Max Efficient, Set by Intel NM
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Enhanced Intel SpeedStep Tech
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
Disabling Enhanced Intel SpeedStep Tech auto disables Intel Turbo Boost Tech.
|
HyperThreading [ALL]
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
CPU Performance
|
Custom
|
Enterprise, HPC, High Throughput, Custom
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
If set as Enterprise then:
-
Hardware Prefetcher is Enabled
-
Adjacent Cache Line Prefetcher is Enabled
-
DCU Streamer Prefetch is Enabled
-
DCU IP Prefetcher is Enabled
If set as High Throughput then:
-
Hardware Prefetcher is Disabled
-
Adjacent Cache Line Prefetcher is Disabled
-
DCU Streamer Prefetch is Disabled
-
DCU IP Prefetcher is Enabled
If set as HPC then:
-
Hardware Prefetcher is Enabled
-
Adjacent Cache Line Prefetcher is Enabled
-
DCU Streamer Prefetch is Enabled
-
DCU IP Prefetcher is Enabled
|
CDN Control
|
Disabled
|
Enabled, Disabled
|
B480 M5B200 M5, , C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
By default, CDN Control is Disabled in the UCSM Manager. (It is Enabled by default in Standalone mode.)
|
Processor CMCI
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
All Onboard LOM Ports
|
Enabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
|
If set as Disabled, then LOM Port 0 OptionROM and LOM Port 1 OptionROM are Disabled.
If set as Enabled, then LOM Port 0 OptionROM and LOM Port 1 OptionROM are Enabled.
|
VMD Enable
|
Disabled
|
Enabled, Disabled
|
C220 M5, C240 M5, B200 M5, B480 M5
|
|
ACS Control SLOT-11
|
Enabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control SLOT-12
|
Enabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control SLOT-13
|
Enabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control SLOT-14
|
Enabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-1
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-2
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-3
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-4
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-5
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-6
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-7
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
ACS Control GPU-8
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
LOM Port 0 OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5
C480 M5
|
|
LOM Port 1 OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5
C480 M5
|
|
SBNVMe1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SBNVMe2 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
IOEMezz1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
IOENVMe1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
IOENVMe2 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
IOESlot1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
IOESlot2 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SBMezz1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SBMezz2 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SIOC1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SIOC2 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SIOCNvme1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SIOCNvme2 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SBLom1 OptionROM
|
Enabled
|
Disabled, Enabled
|
S3260 M5
|
|
SBNVMe1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SBNVMe2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SIOCNVMe1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SIOCNVMe2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SIOC1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SIOC2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SBMezz1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
SBMezz2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
IOESlot1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
IOESlot2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
IOEMezz1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
IOENVMe1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
IOENVMe2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
S3260 M5
|
|
PCIe Slot 1 OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 2 OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 3 OptionROM
|
Enabled
|
Disabled, Enabled
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 4 OptionROM
|
Enabled
|
Disabled, Enabled
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 5 OptionROM
|
Enabled
|
Disabled, Enabled
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 6 OptionROM
|
Enabled
|
Disabled, Enabled
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 7 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
C125 M5
|
|
PCIe Slot 8 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
C125 M5
|
|
PCIe Slot 9 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
C125 M5
|
|
PCIe Slot 10 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
C125 M5
|
|
PCIe Slot 11 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
C125 M5
|
|
PCIe Slot 12 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
C125 M5
|
|
PCIe Slot MLOM OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5
|
|
PCIe Slot MRAID OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5
|
|
PCIe Slot RAID OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N1 OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N2 OptionROM
|
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N3 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N4 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N5 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N6 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N7 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N8 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C240 M5, C480 M5
|
|
PCIe Slot N9 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C480 M5
|
|
PCIe Slot N10 OptionROM |
Enabled
|
Disabled, Enabled
|
C220 M5, C480 M5
|
|
PCIe Slot N11 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N12 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N13 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N14 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N15 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N16 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N17 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N18 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N19 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N20 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N21 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N22 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N23 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot N24 OptionROM |
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot Rear NVMe1 OptionROM
|
Enabled
|
Disabled, Enabled
|
C240 M5, C480 M5
|
|
PCIe Slot Rear NVMe2 OptionROM
|
Enabled
|
Disabled, Enabled
|
C240 M5, C480 M5
|
|
PCIe Slot Rear NVMe3 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot Rear NVMe4 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot Rear NVMe5 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot Rear NVMe6 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot Rear NVMe7 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
PCIe Slot Rear NVMe8 OptionROM
|
Enabled
|
Disabled, Enabled
|
C480 M5
|
|
MRAID Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C220 M5, C240 M5
|
|
RAID Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
|
|
MLOM Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C220 M5, C240 M5
|
|
PCIe Slot 1 Link Speed
|
Auto
|
Disabled, Auto, GEN1 , GEN2, GEN3
|
C220 M5, C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C220 M5, C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 3 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 4 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 5 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 6 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C240 M5
C480 M5
C125 M5
|
|
PCIe Slot 7 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
C125 M5
|
|
PCIe Slot 8 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
C125 M5
|
|
PCIe Slot 9 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
C125 M5
|
|
PCIe Slot 10 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
C125 M5
|
|
PCIe Slot 11 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
C125 M5
|
|
PCIe Slot 12 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C480 M5
C125 M5
|
|
Front NVME1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C220 M5, C240 M5
|
|
Front NVME2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C220 M5, C240 M5
|
|
Rear NVME1 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C240 M5
|
|
Rear NVME2 Link Speed
|
Auto
|
Disabled, Auto, GEN1, GEN2, GEN3
|
C240 M5
|
|
Power On Password
|
Disabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
C125 M5
|
|
P-SATA mode
|
For S3260 M5: AHCI
For all other servers: LSI SW RAID
|
LSI SW RAID, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Processor Prefetch Config
|
Auto
|
Enabled, Disabled,Auto
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
VGA Priority
|
OnBoard
|
OnBoard, OffBoard, OnBoard VGA Disabled
|
C220 M5, C240 M5
|
|
Core Multi Processing
|
All
|
All, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
USB Port Front
|
Enabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
|
|
USB Port Rear
|
Enabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
|
|
USB Port KVM
|
Enabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
|
|
USB Port VMedia
|
Enabled
|
Enabled, Disabled
|
C480 M5
|
|
USB Port Internal
|
Enabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
|
|
USB Port SD Card
|
Enabled
|
Enabled, Disabled
|
C220 M5, C240 M5
C480 M5
|
|
Workload Configuration
|
IO Sensitive
|
Balanced, IO Sensitive
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
IMC Interleave
|
Auto
|
1-way Interleave, 2-way Interleave, Auto
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Sub NUMA Clustering
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
KTI Prefetch
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
XPT Prefetch
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Energy Performance Tuning
|
OS
|
OS, BIOS
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
If set as OS then Energy Performance is Balanced Performance.
If set as BIOS then, Energy Performance is Performance, Balanced Performance, Balanced Power, or Power.
|
Energy Performance
|
Balanced Performance
|
Performance, Balanced Performance, Balanced Power, Power
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Package C State Limit
|
C0 C1 State
|
No Limit, Auto, C0 C1 State, C2, C6 Non Retention, C6 Retention
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
LLC Prefetch
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
CPU Hardware Power Management
|
HWPM Native Mode
|
Disabled, HWPM Native Mode, HWPM OOB Mode, Native Mode with no Legacy
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
If set as HWPM OOB Mode then, ProcessorEppProfile is set as Performance, Balanced Performance, or Balanced Power, Power.
|
IPV6 PXE Support
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
Energy Efficient Turbo
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Autonomous Core C-state
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
ProcessorEppProfile
|
Balanced Performance
|
Performance, Balanced Performance, Balanced Power, Power
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Patrol Scrub
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
Intel Speed Select
|
Base
|
Base, Option 1, Option 2
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5
|
|
BME DMA Mitigation
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
CDN Support for LOMs
|
Disabled
|
Enabled, Disabled
|
C480 M5
|
|
DCPMM Firmware Downgrade
|
Disabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C125 M5
|
|
Core Performance Boost
|
Auto
|
Auto, Disabled
|
C125 M5
|
|
Global C-state Control
|
Auto
|
Auto, Enabled, Disabled
|
C125 M5
|
|
L1 Stream HW Prefetcher
|
Auto
|
Auto, Enabled, Disabled
|
C125 M5
|
|
L2 Stream HW Prefetcher
|
Auto
|
Auto, Enabled, Disabled
|
C125 M5
|
|
AMD Memory Interleaving
|
Auto
|
Auto, None,Channel, Die, Socket
|
C125 M5
|
|
AMD Memory Interleaving Size
|
Auto
|
Auto, 256 Bytes, 512 Bytes, 1 KB, 2 KB
|
C125 M5
|
|
Chipselect Interleaving
|
Auto
|
Auto, Disabled
|
C125 M5
|
|
Bank Group Swap
|
Auto
|
Auto, Enabled, Disabled
|
C125 M5
|
|
Determinism Slider
|
Auto
|
Auto, Power, Performance
|
C125 M5
|
|
IOMMU
|
Auto
|
Auto, Enabled, Disabled
|
C125 M5
|
|
Downcore control
|
Auto
|
Auto, TWO (1 + 1), TWO (2 + 0), THREE (3 + 0), FOUR (2 + 2), FOUR (4 + 0), SIX (3 + 3)
|
C125 M5
|
|
SMT Mode
|
Auto
|
Auto, Off
|
C125 M5
|
|
SVM Mode
|
Enabled
|
Enabled, Disabled
|
C125 M5
|
|
SMEE
|
Enabled
|
Enabled, Disabled
|
C125 M5
|
|
PCIe Slot GPU1 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU2 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU3 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU4 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU5 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU6 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU7 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
PCIe Slot GPU8 OptionROM
|
Enabled
|
Enabled, Disabled
|
C480 M5 ML
|
|
Slot 1 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 2 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 3 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 4 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 5 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 6 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 7 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 8 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 9 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 10 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 11 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 12 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 13 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Slot 14 state
|
Enabled
|
Enabled, Disabled, UEFI Only, Legacy Only
|
C480 M5 ML
|
|
Adaptive Memory Training
|
Enabled
|
Enabled, Disabled
|
B200 M5, B480 M5, C220 M5, C240 M5, C480 M5, S3260 M5, C480 M5 ML
|
|
OptionROM Launch Optimization
|
Enabled
|
Enabled, Disabled
|
All M5 Servers
|
|
BIOS Techlog Level
|
Minimum
|
Maximum, Normal, Minimum
|
All M5 Servers
|
|