Supported Profiles
This chapter describes the SMI-S profiles supported by the Cisco UCS Servers. Complete documentation for the SMI-S profiles can be found at the following URL:
http://www.snia.org/tech_activities/standards/curr_standards/smi
This chapter contains the following topics:
•Host Hardware RAID Controller Profile
•Alarm Profile
•Block Services Profile
•Diagnostics Profile
•Disk Drive Lite Profile
•Disk Sparing Profile
•Erasure Profile
•Extent Composition Profile
•Import Profile
•Indications Profile
•Job Control Profile
•Physical Package Profile
•Storage Enclosure Profile
•Direct Attached Port Profile
•Generic Initiator Port Profile
•Software Inventory Profile
•Software Update Profile
•Storelib Tunneling
Host Hardware RAID Controller Profile
Cisco UCS supports the SMI-S 1.2 Host Hardware RAID Controller Profile as a top-level profile.
This profile supports the following classes:
|
|
CCIM_MegaRAIDHBA |
CIM_ComputerSystem |
A single instance of the CCIM_MegaRAIDHBA class is instantiated for each MegaRAID device discovered by the Cisco UCS system. This class represents the top-level system context for the RAID Controller deployment. All associated logical devices are associated to this instance by the SystemDevice association. |
CCIM_PortController |
CIM_PortController |
A single instance of CCIM_PortController is instantiated for each MegaRAID controller under management by the Cisco UCS system. |
CCIM_EventLog |
CIM_MessageLog |
A single instance of CCIM_EventLog is instantiated for each MegaRAID controller under management by the Cisco UCS system. The EventLog provides access to the underlying log of AENs maintained by the MegaRAID controller. |
CCIM_ConfigLog |
CIM_MessageLog |
A single instance of CCIM_ConfigLog is instantiated for each MegaRAID controller under management by the Cisco UCS system. The ConfigLog contains a single record that represents the current configuration of the MegaRAID controller. |
Alarm Profile
Cisco UCS supports the DMTF Alarm Profile as an extension to the SMI-S 1.2 Host Hardware RAID Controller Profile.
MegaRAID devices have an onboard audible alarm that is supported according to the DMTF Alarm Device Profile version 1.0.0a.
This profile supports the following classes:
|
|
CCIM_AlarmDevice |
CIM_AlarmDevice |
An AlarmDevice is a type of Device that emits audible or indications related to a problem situation. A single instance of CCIM_AlarmDevice is instantiated for each MegaRAIDHBA controller under management by the Cisco UCS system. Instances of this class are only to be created if the alarm hardware is present. |
CCIM_AlarmDeviceCapabilities |
CIM_AlarmDeviceCapabilities |
Instances of this class are generated only if there is an instance of CCIM_AlarmDevice (the alarm hardware is present). |
Block Services Profile
Cisco UCS supports the SMI-S 1.2 Block Services Package in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Block Services functionality encompasses the basic volume management actions and state representation for storage volumes and storage pools.
This profile supports the following classes:
|
|
CCIM_StorageConfigurationCapabilities |
CIM_StorageConfigurationCapabilities |
A single instance of CCIM_StorageConfigurationCapabilities is enumerated for the Pool and Volume StorageConfigurationService. |
CCIM_StorageVolume |
CIM_StorageVolume |
An instance of CCIM_StorageVolume is enumerated for each Logical Disk that is present in MR_LD_LIST structure for each managed RAID controller. |
CCIM_DiskPartition |
CIM_DiskPartition |
The CIM management interface for Cisco UCS is expected to make available information on how logical disks are mapped to operating system partitions. This is not part of the SNIA SMI-S HHRC specification and is added as an LSI extension. |
CCIM_StorageConfigurationService |
CIM_StorageConfigurationService |
An instance of CCIM_StorageConfigurationService is enumerated for each RAID controller. |
CCIM_StoragePool |
CIM_StoragePool |
An instance of CCIM_StoragePool is enumerated for each Array (set of drives) configured on the MegaRAID device. Additionally, an instance of CCIM_StoragePool is enumerated for each virtual StoragePool (arrays configured in the Cisco UCS system, but from which no StorageVolumes have been allocated) that has been configured. The capacity values for StoragePools are calculated based on the RAID level associated with the StoragePool. |
CCIM_GeneratedStorageSetting |
CIM_StorageSetting |
This instance represents the quality of service that can be created from the StoragePool. The client can modify the instance before calling StorageConfigurationService.CreateOrModifyElementFromStoragePool. The client is responsible for deleting the instance if it is not used to create a volume. |
CCIM_StorageVolumeSetting |
CIM_StorageVolumeSetting |
An instance of CCIM_StorageVolumeSetting is instantiated for StorageVolume. Each instance of CCIM_StorageVolumeSetting contains the settings that apply to the associated StorageVolume. Most of the setting data is common for volumes of a particular RAID level. |
CCIM_EnabledLogicalElementCapabilities |
CIM_EnabledLogicalElementCapabilities |
An instance of CCIM_EnabledLogicalElementCapabilities is instantiated for the Storage Configuration Service, and Pool and Volume. |
CCIM_ParentStoragePoolCapabilities |
CIM_StorageCapabilities |
A single instance of CCIM_StoragePoolCapabilities is enumerated for Primordial StoragePool. |
CCIM_StoragePoolCapabilities |
CIM_StorageCapabilities |
An instance of CCIM_StoragePoolCapabilities is enumerated for each created StoragePool. The values for the capabilities are set for each individual Pool, but many of the hard-coded values are set based on the RAID level of the StoragePool. |
CCIM_ParentStoragePool |
CIM_StoragePool |
A single instance of CCIM_ParentStoragePool is enumerated for each MegaRAID controller. This instance represents the usable storage (both allocated and unallocated) attached to the controller. This pool does not include the space on spare drives or the space on drives that are not in the optimal state. In SMI-S, this pool of storage is referred to as the "Primordial" pool. |
CCIM_PottedStorageSetting |
CIM_StorageSetting |
The Primordial StroragePool has an instance of CCIM_PottedStorageSetting for each supported RAID level. The ElementName is used to identify the RAID level. These instances cannot be modified or deleted by the client. |
Diagnostics Profile
Cisco UCS supports the DMTF Diagnostics Profile for the execution of basic tests of the MegaRAID device.
The DMTF Diagnostics Profile exposes the diagnostic capabilities of a device by the CIM model. The MegaRAID firmware exports a single diagnostic command, known as the self-check test. The self-check is intended as an all-in-one type of test, verifying that various components and interfaces are functioning. This test is made available through the MegaRAID CIM provider by an implementation of the diagnostics profile.
This profile supports the following classes:
|
|
CCIM_DiagnosticResultsLog |
CIM_MessageLog |
A single instance of CCIM_DiagnosticResultsLog is created each time a Diagnostics test is executed. |
CCIM_SelfCheckTest |
CIM_DiagnosticsTest |
An instance of CCIM_SelfCheckTest is enumerated for each RAID controller. |
CCIM_HelpService |
CIM_HelpService |
— |
CCIM_SelfCheckIdentity |
CIM_SoftwareIdentity |
An instance of CCIM_SelfCheckIdentity is enumerated for each MegaRAID controller discovered by the Cisco UCS system. |
CCIM_SelfCheckCapabilities |
CIM_DiagnosticServiceCapabilities |
A single instance of CCIM_SelfCheckCapabilities is enumerated for the SelfCheckTest diagnostics instance. |
CCIM_SelfCheckSettings |
CIM_DiagnosticSettings |
An instance of CCIM_SelfCheckSettings is enumerated for each RAID controller. |
(none) |
CIM_SbmaSupportServiceProvider |
Executes a support method. |
Disk Drive Lite Profile
Cisco UCS supports the SMI-S 1.2 Disk Drive Lite in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile. The Disk Drive Lite modeling functionality encompasses the physical and logical aspects of the management of disk drives attached to a RAID device.
In CIM, disk drives are modeled for their logical and physical aspects. Logical aspects of a drive include attributes such as the range of storage blocks contained on the drive. Physical aspects include attributes such as the manufacturer of the device. The Disk Drive Lite profile supplies the linkage between these two views of the disk drives attached to a RAID device.
This profile supports the following classes:
|
|
CCIM_DiskExtent |
CIM_StorageExtent |
An instance of CCIM_DiskExtent is enumerated for each drive (CCIM_DiskDrive). This extent represents the blocks on the drive. Each CCIM_DiskExtent instance is associated to a primordial StoragePool. This association is maintained even if the drive is allocated to a concrete StoragePool. |
CCIM_PhysicalDrive |
CIM_PhysicalPackage |
An instance of CCIM_PhysicalDrive is enumerated for each drive (CCIM_DiskDrive). This instance represents the physical element aspects of the drive. |
CCIM_DriveFirmwareIdentity |
CIM_SoftwareIdentity |
An instance of CCIM_DriveFirmwareIdentity is instantiated for each physical drive associated to a MegaRAID controller. |
CCIM_DiskDrive |
CIM_DiskDrive |
An instance of CCIM_DiskDrive is instantiated for each physical drive associated to a MegaRAID controller. |
Disk Sparing Profile
Cisco UCS supports the SMI-S 1.2 Disk Sparing in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The MegaRAID controller provides automated failover of failed drives. A single set of global spares is utilized to facilitate the failover operation for all assigned drives in the system. Global spares are associated to the global redundacy set. A singleton StorageRedundancySet, aggregating all drives except unassigned spare drives, exists to represent the global sparing domain.
Spares can also be assigned as local to a particular underlying array. Each underlying array is represented as additional StorageRedundancySets. All drives (except assigned spares) are represented as a single StorageRedundancySet. The drives assigned as global spares are related to this set by the CCIM_IsSpare association. All assigned drives (drives assigned to storage pools) are also associated to a StorageRedundancySet that is based on the underlying array containing the drives. The drives assigned as local spares for the underlying array are related to these sets by the CCIM_IsSpare association.
This profile supports the following classes:
|
|
CCIM_SpareConfigurationCapabilities |
CIM_SNIA_SpareConfigurationCapabilites |
A single instance of the CCIM_SpareConfigurationCapabilities class is instantiated for each MegaRAID device. This instance provides information about the capabilities of the service interface for the management of drive sparing. |
CCIM_FailoverStorageExtentsCollection |
CIM_SNIA_FailoverStorageExtentsCollection |
A single instance of the CCIM_FailoverStorageExtentsCollection class is instantiated for each MegaRAID device. This instance collects the failed drives on the device. |
CCIM_SpareConfigurationService |
CIM_SNIA_SpareConfigurationService |
A single instance of the CCIM_SpareConfigurationService class is instantiated for each MegaRAID device. This instance provides the service interface for the management of drive sparing. |
CCIM_StorageRedundancySet |
CIM_StorageRedundancySet |
An instance of the CCIM_StorageRedundancySet class is instantiated for each MegaRAID device to represent the global redundancy set. This instance represents the set of drives available on the device. Drives that are participating in storage (drives that are used to create StorageVolumes) are associated to the Redundancy Set by the memberOfCollection association. Drives that are non-integrated global hot spares are related to the global redundancy set by the IsSpare association. |
Erasure Profile
Cisco UCS supports the SMI-S 1.2 Erasure Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Erasure Profile provides a service interface to initiate erasure actions on storage elements including Storage Volumes and Disk Drives.
This profile supports the following classes:
|
|
CCIM_ErasureSetting |
CIM_ErasureSetting |
An instance of CCIM_ErasureSetting is instantiated for each erasable storage extent (volumes and disks). |
CCIM_ErasureCapabilities |
CIM_ErasureCapabilities |
A single instance of CCIM_ErasureCapabilities is enumerated for the Disk Drive and Volume ErasureService. |
CCIM_ErasureService |
CIM_ErasureService |
A single instance; erases the contents of a storage element by using one of the supported erasure methods. |
Extent Composition Profile
Cisco UCS supports the SMI-S 1.2 Extent Composition Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Extent Composition profile extends the information provided by the Block Services profile to include information about how Volumes are allocated from Storage Pools.
This profile supports the following classes:
|
|
CCIM_StoragePoolCompositeExtent |
CIM_CompositeExtent |
An instance of CCIM_StoragePoolCompositeExtent is enumerated for each underlying span (MegaRAID array) that provides space to an allocated StorageVolume. |
CCIM_FreeExtent |
CIM_StorageExtent |
StorageExtent describes the capabilities and management of the various media that exist to store data and allow data retrieval, and which are not assigned or free. |
CCIM_ComponentExtent |
CIM_StorageExtent |
An instance of CCIM_ComponentExtent is enumerated for each drive allocated to a concrete (non-primordial) StoragePool. |
Import Profile
A MegaRAID controller has the ability to import and clear configurations created by other controllers. The ability to import these "foreign" configurations is crucial to the end-user use case where a MegaRAID card must be replaced. The replacement card imports the existing configurations as foreign configurations.
This feature adds support for importing foreign configurations. There is no official profile that supports importing storage; what follows is an LSI vendor extension.
This profile supports the following classes:
|
|
CCIM_ImportableStorageService |
CIM_Service |
A service class defining extrinsic methods that acts upon CCIM_DriveExtents (members of a CCIM_ForeignExtentsCollection) and CCIM_ImportableConfigurations. |
CCIM_ForeignExtentsCollection |
CIM_SystemSpecificCollection |
This class is used to aggregate all foreign drives. This includes associations to both drives that are importable and those that are not. |
CCIM_ImportableStorageCapabilities |
CIM_Capabilities |
This capabilities class defines the operations available to users of the ImportableStorageService. |
Indications Profile
Cisco UCS supports the SMI-S 1.2 Indications Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Cisco UCS system emits two distinct classes of indications. Device events (AENs) are dispatched to registered clients as instances of the CIM_AlertIndication class. The Cisco UCS system also emits lifecycle indications (subclasses of CIM_InstIndication) to meet the requirements of the supported component profiles. See the individual profile sections for the identity of the lifecycle indications associated with each component profile.
This profile supports the following classes:
|
|
CCIM_AlertIndication |
CIM_AlertIndication |
A CIM_AlertIndication is emitted by the Cisco UCS system for each device event generated by a MegaRAID controller. |
CCIM_LSIESG_PortController_Created |
CIM_AlertIndication |
CCIM_LSIESG_PortController_Deleted |
CIM_AlertIndication |
CCIM_LSIESG_PortController_Modified |
CIM_AlertIndication |
CCIM_LSIESG_DiskDrive_Created |
CIM_AlertIndication |
CCIM_LSIESG_DiskDrive_Deleted |
CIM_AlertIndication |
CCIM_LSIESG_DiskDrive_Modified |
CIM_AlertIndication |
CCIM_LSIESG_StorageVolume_Created |
CIM_AlertIndication |
CCIM_LSIESG_StorageVolume_Deleted |
CIM_AlertIndication |
CCIM_LSIESG_StorageVolume_Modified |
CIM_AlertIndication |
CCIM_LSIESG_StoragePool_Created |
CIM_AlertIndication |
CCIM_LSIESG_StoragePool_Deleted |
CIM_AlertIndication |
CCIM_LSIESG_StoragePool_Modified |
CIM_AlertIndication |
Job Control Profile
Cisco UCS supports the SMI-S 1.2 Job Control Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Job Control Profile provides a representation of executing and completed background jobs that have been instigated on the MegaRAID device by an interaction with the Cisco UCS system.
This profile supports the following classes:
|
|
CCIM_LdInitializeJob |
CIM_ConcreteJob |
An instance of CCIM_LdInitializeJob is instantiated for each request to initialize a volume. |
CCIM_ForegroundInitializationJob |
CIM_ConcreteJob |
An instance of CCIM_ ForegroundInitializationJob is created when foreground initialization is started. |
CCIM_LdReConstructionJob |
CIM_ConcreteJob |
An instance of CCIM_LdReConstructionJob is instantiated for each request to perform a reconstruction operation on a volume. |
CCIM_BadBlockScanJob |
CIM_ConcreteJob |
An instance of CCIM_BadBlockScanJon This job is created when check consistency is fired on a volume. |
CCIM_CheckConsistencyJob |
CIM_ConcreteJob |
An instance of CCIM_ CheckConsistencyJob created when check consistency is fired on a volume. |
CCIM_PdRebuildJob |
CIM_ConcreteJob |
An instance of CCIM_ PdRebuildJob is created when rebuild operation is started on a physical disk. |
CCIM_SelfCheckJobProvider |
|
An instance of CCIM_SelfCheckJob is created each time the SelfCheckTest is executed. |
Physical Package Profile
Cisco UCS supports the SMI-S Physical Package Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The scope for the application of the Physical Package Profile to the MegaRAID product is limited to the RAID controller itself, and it does not include the physical deployment of the MegaRAID card within the server chassis. In addition, the scope of this profile does not extend to the physical aspects of the attached enclosures. Physical Package aspects of the attached enclosures are modeled as part of the Storage Enclosure Profile.
This profile supports the following classes:
|
|
CCIM_MegaRAIDProduct |
CIM_Product |
A single instance of the CCIM_MegaRAIDProduct class is instantiated for each MegaRAID controller discovered by the Cisco UCS system. |
CCIM_EnclosureProduct |
CIM_Product |
An instance of the CCIM_EnclosureProduct class is instantiated for each enclosure discovered by the Cisco UCS system. |
CCIM_DiskDriveProduct |
CIM_Product |
An instance of the CCIM_DiskDriveProduct class is instantiated for each disk drive discovered by the Cisco UCS system. |
CCIM_BatteryPackage |
CIM_PhysicalPackage |
A single instance of the CCIM_BatteryPackage class is instantiated for each MegaRAID controller managed by the Cisco UCS system. The instance exists only when the battery package is present on the MegaRAID Device. |
CCIM_PhysicalCard |
CIM_Card |
A single instance of CCIM_PhysicalCard is enumerated for each deployed MegaRAID card discovered by the Cisco UCS system. |
CCIM_BatteryCapabilities |
CIM_EnabledLogicalElementCapabilities |
A single instance of the CCIM_BatteryCapabilities class is instantiated for each MegaRAID controller managed by the Cisco UCS system. The instance exists even when the physical battery package is not present on the MegaRAID device. Instead of removing the instance from the model, the missing condition is modeled as a device state of the associated Battery. |
CCIM_Battery |
CIM_Battery |
A single instance of the CCIM_Battery class is instantiated for each MegaRAID controller managed by the Cisco UCS system. The instance exists even when the physical battery package is not present on the MegaRAID device. Instead of removing the instance from the model, the missing condition is modeled as a device state. |
CCIM_PhysicalAssetCapabilities |
CIM_PhysicalAssetCapabilities |
An instance of CCIM_PhysicalAssetCapabilities is enumerated for each deployed MegaRAID controller discovered by the Cisco UCS system. |
Storage Enclosure Profile
Cisco UCS supports SMI-S 1.2 Storage Enclosure Profile to represent the physical and logical aspects of storage enclosures.
The Storage Enclosure Profile models the fans, power supplies, and alarms that are present in storage enclosures attached to MegaRAID controllers. In addition, the profile supports a representation of the Enclosure Service Module as a subtype of the PortController class. Finally, the profile models the deployment of the physical drive devices in the enclosures, including the slot location for each drive.
This profile supports the following classes:
|
|
CCIM_DriveSlot |
CIM_Slot |
An instance of CCIM_DriveSlot is instantiated for each drive slot reported as contained in all discovered enclosures. |
CCIM_EnclosureChassis |
CIM_Chassis |
An instance of CCIM_EnclosureChassis is instantiated for each Enclosure discovered by MegaRAID controllers under management by the Cisco UCS system. |
CCIM_PhysicalFan |
CIM_PhysicalPackage |
An instance of CCIM_PhysicalFan is instantiated for each fan reported as present in all discovered enclosures. This class represents the physical package for the fan device. |
CCIM_PowerSupply |
CIM_PowerSupply |
An instance of CCIM_PowerSupply is instantiated for each power supply reported as present in all discovered enclosures. |
CCIM_EnclosureAlarm |
CIM_AlarmDevice |
An instance of CCIM_EnclosureAlrm is instantiated for each alarm reported as present in all discovered enclosures. |
CCIM_ESMController |
CIM_PortController |
An instance of CCIM_ESMController is instantiated for each ESM component reported as present in all discovered enclosures. |
CCIM_PowerSupplyPackage |
CIM_PhysicalPackage |
An instance of CCIM_PowerSupply is instantiated for each power supply reported as present in all discovered enclosures. |
CCIM_EnclosureFan |
CIM_Fan |
An instance of CCIM_Fan is instantiated for each fan reported as present in all discovered enclosures. |
CCIM_ESMComponent |
CIM_Card |
An instance of CCIM_ESMComponent is instantiated for each ESM component reported as present in all discovered enclosures. |
Direct Attached Port Profile
Cisco UCS supports the SMI-S 1.2 Direct Attached Port Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Direct Attached Port Profile models the interface between the MegaRAID controller and the host system.
This profile supports the following classes:
|
|
CCIM_DAPort |
CIM_DAPort |
A single instance of CCIM_DAPort is instantiated for each MegaRAID controller managed by the Cisco UCS system. |
CCIM_SCSIProtocolEndpoint |
CIM_SCSIProtocolEndpoint |
A single instance of CCIM_SCSIProtocolEndpoint is instantiated for each MegaRAID controller managed by the Cisco UCS system. |
CCIM_SCSIProtocolController |
CIM_SCSIProtocolController |
A single instance of CCIM_SCSIProtocolController is instantiated for each MegaRAID controller managed by the Cisco UCS system. |
CCIM_PCIDevice |
CIM_PCIDevice |
The CCIM_PCIDevice class supplies detailed information on the PCI controller. |
Generic Initiator Port Profile
Cisco UCS supports the SMI-S 1.2 Generic Initiator Port Profile in the manner specified by the SMI-S 1.2 Host Hardware RAID Controller Profile.
The Generic Initiator Port Profile supports two methods for representing drive-side connectivity. Cisco UCS uses the Connectivity Collection method. Cisco UCS enumerates a CCIM_ConnectivityCollection for each SASPort configured on the MegaRAID controller. In Serial Attached SCSI (SAS), a Port is a set of Physical Interfaces that share the same SAS address. The initiator port on the controller and all target ports on drives that are connected to the controller's port are included in the CCIM_ConnectivityCollection.
This profile supports the following classes:
|
|
CCIM_InitiatorProtocolEndpoint |
CIM_SCSIProtocolEndpoint |
An instance of CCIM_InitiatorProtocolEndpoint is instantiated for each port configured in the deviceInterface structure. |
CCIM_ATAProtocolEndpoint |
CIM_ATAProtocolEndpoint |
An instance of CCIM_ATAProtocolEndpoint is instantiated for each port configured in the deviceInterface structure. |
CCIM_TargetProtocolEndpoint |
CIM_SCSIProtocolEndpoint |
An instance of CCIM_TargetProtocolEndpoint is instantiated for each connected port, on each Disk Drive configured in the MegaRAID firmware. A connection is indicated by a bit being set in the MR_PD_Address.connectedPortBitmap structure. |
CCIM_TargetATAProtocolEndpoint |
CIM_ATAProtocolEndpoint |
An instance of CCIM_TargetProtocolEndpoint is instantiated for each connected port, on each Disk Drive configured in the MegaRAID firmware. A connection is indicated by a bit being set in the MR_PD_Address.connectedPortBitmap structure. |
CCIM_SASSATAPort |
CIM_SASSATAPort |
An instance of CCIM_TargetProtocolEndpoint is instantiated for each connected port, on each Disk Drive configured in the MegaRAID firmware. A connection is indicated by a bit being set in the MR_PD_Address.connectedPortBitmap structure. |
CCIM_ConnectivityCollection |
CIM_ConnectivityCollection |
An instance of CCIM_ConnectivityCollection is instantiated for each port configured in the deviceInterface structure. |
Software Inventory Profile
The Software Inventory Profile provides a representation of the firmware deployed on the MegaRAID controller. In addition to the base firmware version, information about the Controller BIOS and the device driver software are also provided.
This profile supports the following classes:
|
|
CCIM_ControllerBIOSIdentity |
CIM_SoftwareIdentity |
An instance of CCIM_ControllerBIOSIdentity is enumerated for each MegaRAID controller discovered by Cisco UCS system. |
CCIM_FirmwarePackageIdentity |
CIM_SoftwareIdentity |
In the context of a single instance representing the "current" firmware package instance, that instance remains unchanged. The model given above identifies a second instance, an "available" instance that has different properties. |
CCIM_DriverIdentity |
CIM_SoftwareIdentity |
An instance of CCIM_DriverIdentity is enumerated for each MegaRAID controller discovered by Cisco UCS system. |
CCIM_ControllerFirmwareIdentity |
CIM_SoftwareIdentity |
An instance of CCIM_ControllerFirmwareIdentity is enumerated for each MegaRAID controller discovered by Cisco UCS system. |
Software Update Profile
The Software Update Profile provides an interface to upgrade the firmware deployed on the MegaRAID controller.
This profile supports the following classes:
|
|
CCIM_SoftwareInstallationServiceCapabilities |
CIM_SoftwareInstallationServiceCapabilities |
An instance of CCIM_SoftwareInstallationServiceCapabilities is enumerated for each RAID controller. |
CCIM_SoftwareInstallationService |
CIM_SoftwareInstallationService |
An instance of CCIM_SoftwareInstallationService is enumerated for each RAID controller. |
Storelib Tunneling
This profile supports the following classes:
|
|
(none) |
CIM_StoreLibCmd |
A single instance is generated for each controller. |
(none) |
CIM_StoreLibCommandService |
This class is used to invoke Storelib command directly from provider. |