Using the Cisco UCS Manager Adapter

This chapter includes the following sections:

Discovering the Resources Manually

From the Cisco UCS Management Pack, Release 2.0(3), you can manually discover the objects and select the resource kinds or the resources to be discovered and for which metrics must be collected.


Note


The following limitations occurs while collecting the metrics manually:

  • Metrics for port channels, such as the UCS FI Eth port channel, UCS FI FC port channel, and UCS FI FCoE port channel are collected when UCS FIs are selected for collection

  • Metrics for UCS service profiles are collected when UCS servers are selected for collection

  • Inventory is established when the immediate parent of an object is selected for collection


Before you begin

Select the Auto Discover New Resource value as False. For instructions on how to configure an adapter instance of the UCS Manager adapter, see Creating and Editing Cisco UCS Manager Adapter Instances.

Procedure


Step 1

Access the Operations Manager web UI.

Step 2

For the release version vROps 8.6 and later, navigate to Environment > Inventory.

Note

 
  • For the release version vROps 8.18 and later, navigate to Operations > Configuration > Inventory Management > Manual Discovery.

  • For the release version vROps 8.5 and earlier, navigate to Administration > Inventory.

Step 3

From Inventory, expand Adapter Instances > UCS Manager Adapter.

Step 4

From the list, select the adapter instance for which resources must be discovered.

Step 5

Click the Discover Objects icon.

Discover Objects page appears.

Step 6

Review and complete the following:

Name

Descriptions

Collector

Lists the available collector or the collector groups.

Adapter Type

Lists the available adapter types.

Adapter Instance

Lists the available adapter instances.

Discovery Info

Select UCSM Resource Discovery.

Only New Objects

Whether to discover new objects or discover and list all the objects.

Step 7

Click Ok.


Data Collection

During each collection cycle the adapter retrieves metric values, events and relationships from the UCS domain.

The UCS Manager adapter collects the following statistics from the UCS domains.

ResourceKind Name: UCS Domain

Metric Supported:

Metric-Key

Description

Availability

Availability of UCS Domain

Property Supported:

Property

Description

UCS Manager Version

Version of UCS Manager

ResourceKind Name: UCS Chassis

Metric Supported:

Metric-Key

Description

Operational State

Operational State of Chassis

Input Power(Watts)

Input Power in watts

Output Power(Watts)

Output Power in watts

Fan Module | Exhaust Temperature (Celsius)

Exhaust Temperature of fan module in celsius

Fan Module | Fan | Speed (RPM)

Speed of Fan in RPM

PSU | Input Voltage (Volts)

Input Voltage in volts

PSU | Internal Temperature (Celsius)

Internal Temperature in celsius

PSU | Output Current (Amps)

Output Current in amps

PSU | Output Power (Watts)

Output Power in watts

PSU | Output Voltage (Volts)

Output Voltage in volts

Properties Supported:

Property

Description

Serial

Serial of the UCS chassis

Model

Model of UCS chassis

PSU | Serial

Serial of the PSU

PSU | Model

Model of the PSU

PSU | Firmware Version

Firmware version of the PSU

Fan Module | Serial

Serial of the Fan Module

Fan Module | Model

Model of the Fan Module

Fan Module | Fan | Serial

Serial of the Fan

Fan Module | Fan | Model

Model of the Fan

Storage Enclosure | Serial

Serial of the Storage Enclosure

Storage Enclosure | Model

Model of the Storage Enclosure

Storage Enclosure | Vendor

Vendor of the Storage Enclosure

Storage Enclosure | Local Disk | Serial

Serial of the Local Disk

Storage Enclosure | Local Disk | Model

Model of the Local Disk

Storage Enclosure | Local Disk | Firmware Version

Firmware Version of the Local Disk

Storage Enclosure | Local Disk | Servers Associated

Servers associated with the Local Disk

Storage Enclosure | Local Disk | Vendor

Vendor of the Local Disk

User Label

User Label of Chassis

ResourceKind Name: UCS Server

Metric Supported:

Metric-Key

Description

Operational Power

Operational Power of the server

Operational State

Operational State of the server

Blade Server | Server Motherboard | Memory Array | Memory Unit | DDR Array Temperature (Celsius)

DDR array temperature in celsius

Blade Server | Server Motherboard | Power | Consumed Power (Watts)

Consumed power in watts

Blade Server | Server Motherboard | Power | Input Current (Amps)

Input current in amps

Blade Server | Server Motherboard | Power | Input Voltage (Volts)

Input voltage in volts

Blade Server | Server Motherboard | Processor Unit | CPU Temperature (Celsius)

CPU temperature in celsius

Blade Server | Server Motherboard | Processor Unit | Input Current (Amps)

Input Current in amps

Blade Server | Server Motherboard | Temperature-Stats | Front Temperature (Celsius)

Front temperature in celsius

Blade Server | Server Motherboard | Temperature-Stats | Rear Temperature (Celsius)

Back temperature in celsius

Rack Unit | Server Motherboard | Memory Array | Memory Unit | DDR Array Temperature (Celsius)

DDR array temperature in celsius

Rack Unit | Server Motherboard | Power-Stats | Consumed Power (Watts)

Consumed power in watts

Rack Unit | Server Motherboard | Power-Stats | Input Current (Amps)

Input current in amps

Rack Unit | Server Motherboard | Power-Stats | Input Voltage (Volts)

Input voltage in volts

Rack Unit | Server Motherboard | Processor Unit | CPU Temperature (Celsius)

CPU temperature in celsius

Rack Unit | Server Motherboard | Processor Unit | Input Current (Amps)

Input Current in amps

Rack Unit | Server Motherboard | Temp-Stats | Front Temperature (Celsius)

Front temperature in celsius

Rack Unit | Server Motherboard | Temp-Stats | Rear Temperature (Celsius)

Back temperature in celsius

Rack Unit | Fan Module | Fan | Speed (RPM)

Speed of Fan in RPM

Rack Unit | Fan Module | Exhaust Temperature (Celsius)

Exhaust temperature in celsius

Rack Unit | PSU | Input Voltage (Volts)

Input Voltage in volts

Rack Unit | PSU | Internal Temperature (Celsius)

Internal Temperature in celsius

Rack Unit | PSU | Output Current (Amps)

Output Current in amps

Rack Unit | PSU | Output Power (Watts)

Output Power in watts

Rack Unit | PSU | Output Voltage (Volts)

Output Voltage in volts

Properties Supported:

Property

Description

Serial

Serial of the UCS Server

Current Operational Power

Operational Power of the Server

Model

Model of the Server

BIOS Version

BIOS Version of the Server

Board Controller Version

Board Controller Version of the Server

CIMC Controller Version

CIMC Controller Version of the Server

Blade Server | Adaptor Unit | Firmware Version

Firmware Version of the Server Adaptor

Blade Server | Adaptor Unit | Model

Model of the Server Adaptor

Blade Server | Adaptor Unit | Serial

Serial of the Server Adaptor

Blade Server | Mother Board| Storage Controller | Firmware Version

Firmware Version of the Storage Controller

Blade Server | Mother Board| Storage Controller | Model

Model of the Storage Controller

Blade Server | Mother Board| Storage Controller | Serial

Serial of the Storage Controller

Blade Server | Mother Board| Storage Controller | Vendor

Vendor of the Storage Controller

Blade Server | Mother Board| Storage Controller | Local Disk | Firmware Version

Firmware Version of the Local Disk

Blade Server | Mother Board| Storage Controller | Local Disk | Model

Model of the Local Disk

Blade Server | Mother Board| Storage Controller | Local Disk | Serial

Serial of the Local Disk

Blade Server | Mother Board| Storage Controller | Local Disk | Vendor

Vendor of the Local Disk

Rack Unit | Adaptor Unit | Firmware Version

Firmware Version of the Server Adaptor

Rack Unit | Adaptor Unit | Model

Model of the Server Adaptor

Rack Unit | Adaptor Unit | Serial

Serial of the Server Adaptor

Rack Unit | Mother Board | Storage Controller | Firmware Version

Firmware Version of the Storage Controller

Rack Unit | Mother Board | Storage Controller | Model

Model of the Storage Controller

Rack Unit | Mother Board | Storage Controller | Serial

Serial of the Storage Controller

Rack Unit | Mother Board | Storage Controller | Vendor

Vendor of the Storage Controller

Rack Unit | Mother Board | Storage Controller | Local Disk | Firmware Version

Firmware Version of the Local Disk

Rack Unit | Mother Board | Storage Controller | Local Disk | Model

Model of the Local Disk

Rack Unit | Mother Board | Storage Controller | Local Disk | Serial

Serial of the Local Disk

Rack Unit | Mother Board | Storage Controller | Local Disk | Vendor

Vendor of the Local Disk

Rack Unit | Fan Module | Model

Model of the Fan Module

Rack Unit | Fan Module | Serial

Serial of the Fan Module

Rack Unit | Fan Module | Fan | Model

Model of the Fan

Rack Unit | Fan Module | Fan | Serial

Serial of the Fan

Rack Unit | PSU | Firmware Version

Firmware Version of the PSU

Rack Unit | PSU | Model

Model of the PSU

Rack Unit | PSU | Serial

Serial of the PSU

UUID

Unique Identifier of the Server

Blade Server | Storage Enclosure | Serial

Serial of the Storage Enclosure

Blade Server | Storage Enclosure | Model

Model of the Storage Enclosure

Blade Server | Storage Enclosure | Vendor

Vendor of the Storage Enclosure

Blade Server | Storage Enclosure | Local Disk | Serial

Serial of the Local Disk

Blade Server | Storage Enclosure | Local Disk | Model

Model of the Local Disk

Blade Server | Storage Enclosure | Local Disk | Firmware Version

Firmware Version of the Local Disk

Blade Server | Storage Enclosure | Local Disk | Vendor

Vendor of the Local Disk

User Label

User Label of Chassis

Server Name

Name of the server

ResourceKind Name: UCS Fabric Interconnect

Metrics Supported:

Metric Key

Description

Operational State

Operational State of FI

Load-Average

CPU Load (Average) of Fabric Interconnect

Memory Available-Average

Memory Available (Average) of Fabric Interconnect in MB

Memory Cached- Average

Memory Cached (Average) of Fabric Interconnect in MB

Fan Module | Fan | Speed (RPM)

Speed of Fan in RPM

Fan Module | Exhaust Temperature (Celsius)

Exhaust temperature of Fan in celsius

PSU | Current (Amps)

Output Current in amps

PSU | Power (Watts)

Output Power in watts

PSU | Voltage (Volts)

Output Voltage in volts

Properties Supported:

Property

Description

Serial

Serial of the UCS FI

Model

Model of the UCS FI

Kernel Version

Kernel Version of the UCS FI

Firmware Version

Firmware Version of the UCS FI

PSU | Serial

Serial of the PSU

PSU | Model

Model of the PSU

PSU | Firmware Version

Firmware Version of the PSU

Fan Module | Serial

Serial of the Fan Module

Fan Module | Model

Model of the Fan Module

Fan Module | Fan | Serial

Serial of the Fan

Fan Module | Fan | Model

Model of the Fan

ResourceKind Name: UCS Service Profile

Metric Supported:

Metric Key

Description

Association State

Association State of Service profile

vNIC | Error Counter | Rx-Error-Delta (packets/sec)

Delta of Error Packets received per second

vNIC | Error Counter | Tx-Error-Delta (packets/sec)

Delta of Error Packets transmitted per second

vNIC | Error Counter | Rx-Error-Total (packets)

Total Error Packets Received

vNIC | Error Counter | Tx-Error-Total (packets)

Total Error Packets transmitted

vNIC | Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

vNIC | Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

vNIC | Rx Counter | Rx-Total (bytes)

Total Bytes received

vNIC | Rx Counter | Rx-Total (packets)

Total Packets received

vNIC | Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

vNIC | Tx Counter | Tx-Total (Bps)

Total Bytes transmitted per second

vNIC | Tx Counter | Tx-Total (packets/sec)

Total Error Packets transmitted per second

vNIC | Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

vHBA | Error Counter | Rx-Error-Delta (packets/Sec)

Delta of Error Packets received per second

vHBA | Error Counter | Tx-Error-Delta (packets/Sec)

Delta of Error Packets transmitted per second

vHBA | Error Counter | Rx-Error-Total (packets)

Total Error Packets Received

vHBA | Error Counter | Tx-Error-Total (packets)

Total Error Packets transmitted

vHBA | Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

vHBA | Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

vHBA | Rx Counter | Rx-Total (bytes)

Total Bytes received

vHBA | Rx Counter | Rx-Total (packets)

Total Packets received

vHBA | Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

vHBA | Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

vHBA | Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

vHBA | Tx Counter | Tx-Total (packets)

Total Packets transmitted

iSCSI vNIC | Error Counters | Rx-Error-Delta (packets/Sec)

Delta of Error Packets received per second

iSCSI vNIC | Error Counters | Tx-Error-Delta (packets/Sec)

Delta of Error Packets transmitted per second

iSCSI vNIC | Error Counters | Rx-Error-Total (packets)

Total Error Packets Received

iSCSI vNIC | Error Counters | Tx-Error-Total (packets)

Total Error Packets transmitted

iSCSI vNIC | Rx Counters | Rx-Delta (Bps)

Delta of Bytes received per second

iSCSI vNIC | Rx Counters | Rx-Delta (packets/sec)

Delta of Packets received per second

iSCSI vNIC | Rx Counters | Rx-Total (bytes)

Total Bytes received

iSCSI vNIC | Rx Counters | Rx-Total (packets)

Total Packets received

iSCSI vNIC | Tx Counters | Tx-Delta (Bps)

Delta of Bytes transmitted per second

iSCSI vNIC | Tx Counters | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

iSCSI vNIC | Tx Counters | Tx-Total (bytes)

Total Bytes transmitted

iSCSI vNIC | Tx Counters | Tx-Total (packets)

Total Packets transmitted

ResourceKind Name: UCS IO Module

Metric Supported:

Metric-Key

Description

Operational State

Operational state of the IO Module

Backplane Port | Error Counter | Align-Delta(packets/sec)

Align Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Deferred-Tx-Delta(packets/sec)

Deferred Tx Delta of Error Packets transmitted per second

Backplane Port | Error Counter | FCS-Delta(packets/sec)

FCS Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Int-Mac-Rx-Delta(packets/sec)

Int Mac Rx Delta of Error Packets received per second

Backplane Port | Error Counter | Int-Mac-Tx-Delta(packets/sec)

Int Mac Tx Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Out Discard-Delta(packets/sec)

Out Discard Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Rx Error-Delta(packets/sec)

Delta of Error Packets received per second

Backplane Port | Error Counter | Rx Error-Total(packets)

Total Error Packets received

Backplane Port | Error Counter | Tx Error-Delta(packets/sec)

Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Tx Error-Total(packets)

Total Error Packets transmitted

Backplane Port | Error Counter | Under-Sized-Delta(packets/sec)

Under Sized Delta of Error Packets transmitted per second

Backplane Port | Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

Backplane Port | Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

Backplane Port | Rx Counter | Rx-Total (bytes)

Total Bytes received

Backplane Port | Rx Counter | Rx-Total (packets)

Total Packets received

Backplane Port | Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Backplane Port | Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Backplane Port | Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

Backplane Port | Tx Counter | Tx-Total (packets)

Total Packets transmitted

Properties Supported:

Property

Description

Serial

Serial of the UCS IOM

Model

Model of the IOM

Firmware Version

Firmware Version of the IOM

ResourceKind Name: UCS Fabric Extender

Metric Supported:

Metric-Key

Description

Operational State

Operational State of Fabric Extender

PSU | Current (Amps)

Output Current in amps

PSU | Power (Watts)

Output Power in watts

PSU | Voltage (Volts)

Output Voltage in volts

Fan | Speed (RPM)

Output Fan speed in RPM

Properties Supported:

Property

Description

Serial

Serial of the UCS Fabric Extender

Model

Model of the UCS Fabric Extender

Firmware Version

Firmware Version of the UCS Fabric Extender

PSU | Serial

Serial of the PSU

PSU | Model

Model of the PSU

PSU | Firmware Version

Firmware Version of the PSU

Fan | Serial

Serial of the fan

Fan | Model

Model of the fan

ResourceKind Name: UCS FI Server Port , UCS FI Uplink Port , UCS FI FcoE Storage Port, UCS FI FcoE Uplink Port and UCS FI Appliance Port

Metric Supported:

Metric-Key

Description

Operational State

Operational State of FI Ports

Error Counter | Align-Delta (packets/sec)

Align Delta of Error Packets transmitted per second

Error Counter | Deferred-Tx-Delta (packets/sec)

Deferred Tx Delta of Error Packets transmitted per second

Error Counter | FCS-Delta (packets/sec)

FCS Delta of Error Packets transmitted per second

Error Counter | Int-Mac-Rx-Delta (packets/sec)

Int Mac Rx Delta of Error Packets received per second

Error Counter | Int-Mac-Tx-Delta (packets/sec)

Int Mac Tx Delta of Error Packets transmitted per second

Error Counter | Out Discard-Delta (packets/sec)

Out Discard Delta of Error Packets transmitted per second

Error Counter | Rx Error-Delta (packets/sec)

Delta of Error Packets received per second

Error Counter | Rx Error-Total (packets)

Total Error Packets received

Error Counter | Tx Error-Delta (packets/sec)

Delta of Error Packets transmitted per second

Error Counter | Tx Error-Total (packets)

Total Error packets transmitted

Error Counter | Under-Sized-Delta (packets/sec)

Under Sized Delta of Error Packets transmitted per second

Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

Rx Counter | Rx-Total (bytes)

Total Bytes received

Rx Counter | Rx-Total (packets)

Total Packets received

Rx Counter | Rx-Utilization (%)

Inbound Traffic Bandwidth Utilization

Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

Tx Counter | Tx-Total (packets)

Total Packets transmitted

Tx Counter | Tx-Utilization (%)

Outbound Traffic Bandwidth Utilization

Property Supported:

Property

Description

Operational Speed (bps)

Operating Speed of the port

ResourceKind Name: UCS FI FCoE Port Channel

Metric Supported:

Metric-Key

Description

Operational State

Operational State of FI FCoE Port Channel

Error Counter | Rx Error-Delta (packets/sec)

Delta of Error Packets received per second

Error Counter | Rx Error-Total (packets)

Total Error Packets received

Error Counter | Tx Error-Delta (packets/sec)

Delta of Error Packets transmitted per second

Error Counter | Tx Error-Total (packets)

Total Error Packets transmitted

Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

Rx Counter | Rx-Total (bytes)

Total Bytes received

Rx Counter | Rx-Total (packets)

Total Packets received

Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

Tx Counter | Tx-Total (packets)

Total Packets transmitted

ResourceKind Name: UCS FI FC Port Channel

Metric Supported:

Metric-Key

Description

Operational State

Operational State of FI FC Port Channel

Error Counter | Rx Error-Delta (packets/sec)

Delta of Error Packets received per second

Error Counter | Rx Error-Total (packets)

Total Error Packets received

Error Counter | Tx Error-Delta (packets/sec)

Delta of Error Packets transmitted per second

Error Counter | Tx Error-Total (packets)

Total Error packets transmitted

Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

Rx Counter | Rx-Total (bytes)

Total Bytes received

Rx Counter | Rx-Total (packets)

Total Packets received

Rx Counter | Rx-Utilization (%)

Inbound Traffic Bandwidth Utilization

Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

Tx Counter | Tx-Total (packets)

Total Packets transmitted

Tx Counter | Tx-Utilization (%)

Outbound Traffic Bandwidth Utilization

Property Supported:

Property

Description

Operational Speed (bps)

Operating Speed of the UCS FI FC Port Channel

ResourceKind Name: UCS FI Eth Port Channel

Metric Supported:

Metric-Key

Description

Operational State

Operational State of FI Eth Port Channel

Error Counter | Align-Delta (packets/sec)

Align Delta of Error Packets transmitted per second

Error Counter | Deferred-Tx-Delta (packets/sec)

Deferred Tx Delta of Error Packets transmitted per second

Error Counter | FCS-Delta (packets/sec)

FCS Delta of Error Packets transmitted per second

Error Counter | Int-Mac-Rx-Delta (packets/sec)

Int Mac Rx Delta of Error Packets received per second

Error Counter | Int-Mac-Tx-Delta (packets/sec)

Int Mac Tx Delta of Error Packets transmitted per second

Error Counter | Out Discard-Delta (packets/sec)

Out Discard Delta of Error Packets transmitted per second

Error Counter | Rx Error-Delta (packets/sec)

Delta of Error Packets received per second

Error Counter | Rx Error-Total (packets)

Total Error Packets received

Error Counter | Tx Error-Delta (packets/sec)

Delta of Error Packets transmitted per second

Error Counter | Tx Error-Total (packets)

Total Error packets transmitted

Error Counter | Under-Sized-Delta (packets/sec)

Under Sized Delta of Error Packets transmitted per second

Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

Rx Counter | Rx-Total (bytes)

Total Bytes received

Rx Counter | Rx-Total (packets)

Total Packets received

Rx Counter | Rx-Utilization (%)

Inbound Traffic Bandwidth Utilization

Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

Tx Counter | Tx-Total (packets)

Total Packets transmitted

Tx Counter | Tx-Utilization (%)

Outbound Traffic Bandwidth Utilization

Property Supported:

Property

Description

Operational Speed (bps)

Operating Speed of the UCS FI Eth Port Channel

ResourceKind Name: UCS FI FC Port

Metric Supported:

Metric-Key

Description

Operational State

Operational State of FI FC Port

Error Counter | Rx-Error-Delta (packets/Sec)

Delta of Error Packets received per second

Error Counter | Tx-Error-Delta (packets/Sec)

Delta of Error Packets transmitted per second

Error Counter | Rx-Error-Total (packets)

Total Error Packets Received

Error Counter | Tx-Error-Total (packets)

Total Error Packets transmitted

Rx Counter | Rx-Delta (Bps)

Delta of Bytes received per second

Rx Counter | Rx-Delta (packets/sec)

Delta of Packets received per second

Rx Counter | Rx-Total (bytes)

Total Bytes received

Rx Counter | Rx-Total (packets)

Total Packets received

Rx Counter | Rx-Utilization (%)

Inbound Traffic Bandwidth Utilization

Tx Counter | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Tx Counter | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Tx Counter | Tx-Total (bytes)

Total Bytes transmitted

Tx Counter | Tx-Total (packets)

Total Packets transmitted

Tx Counter | Tx-Utilization (%)

Outbound Traffic Bandwidth Utilization

Property Supported:

Property

Description

Operational Speed (bps)

Operating Speed of the UCS FI FC port

ResourceKind Name: UCS FI IO Module

Metric Supported:

Metric-Key

Description

Operational State

Operational state of the UCS FI IO Module

Backplane Port | Error Counter | Align-Delta(packets/sec)

Align Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Deferred-Tx-Delta(packets/sec)

Deferred Tx Delta of Error Packets transmitted per second

Backplane Port | Error Counter | FCS-Delta (packets/sec)

FCS Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Int-Mac-Rx-Delta(packets/sec)

Int Mac Rx Delta of Error Packets received per second

Backplane Port | Error Counter | Int-Mac-Tx-Delta(packets/sec)

Int Mac Tx Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Out Discard-Delta(packets/sec)

Out Discard Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Rx Error-Delta(packets/sec)

Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Rx Error-Total(packets)

Total Error Packets received

Backplane Port | Error Counter | Tx Error-Delta(packets/sec)

Delta of Error Packets transmitted per second

Backplane Port | Error Counter | Tx Error-Total(packets)

Total Error packets transmitted

Backplane Port | Error Counter | Under-Sized-Delta(packets/sec)

Under Sized Delta of Error Packets transmitted per second

Backplane Port | Rx Counters | Rx-Delta (Bps)

Delta of Bytes received per second

Backplane Port | Rx Counters | Rx-Delta (packets/sec)

Delta of Packets received per second

Backplane Port | Rx Counters | Rx-Total (bytes)

Total Bytes received

Backplane Port | Rx Counters | Rx-Total (packets)

Total Packets received

Backplane Port | Tx Counters | Tx-Delta (Bps)

Delta of Bytes transmitted per second

Backplane Port | Tx Counters | Tx-Delta (packets/sec)

Delta of Packets transmitted per second

Backplane Port | Tx Counters | Tx-Total (bytes)

Total Bytes transmitted

Backplane Port | Tx Counters | Tx-Total (packets)

Total Packets transmitted

Property Supported:

Property

Description

Serial

Serial of the UCS FI IO Module

Model

Model of the FI IO Module

Firmware Version

Firmware version of the FI IO Module

ResourceKind Name: UCS System IO Controller

Metric Supported:

Metric-Key

Description

Operational State

Operational State of the UCS SIOC

Temperature | Cmc Temperature (Celsius)

Cmc temperature in celsius

Temperature | Front Temperature (Celsius)

Front temperature in celsius

Temperature | Mid Temperature (Celsius)

Mid temperature in celsius

Temperature | Rear Temperature (Celsius)

Rear temperature in celsius

Temperature | Vic Temperature (Celsius)

Vic temperature in celsius

Shared Adapter | Operational State

Operational State of the Shared Adapter

Shared Adapter | Fabric Port | NI Error Counters | Too Short (errors)

Too Short errors in the fabric port

Shared Adapter | Fabric Port | NI Error Counters | Too Long (errors)

Too Long errors in the fabric port

Shared Adapter | Fabric Port | NI Error Counters | In Range (errors)

In Range errors in the fabric port

Shared Adapter | Fabric Port | NI Error Counters | Frame Tx (errors)

Fame Tx errors in the fabric port

Shared Adapter | Fabric Port | NI Error Counters | Crc (errors)

Crc errors in the fabric port

Property Supported:

Property

Description

Serial

Serial of the UCS SIOC

Model

Model of the UCS SIOC

Firmware Version

Firmware version of the UCS SIOC

Shared Adapter | Serial

Serial of the Shared Adapter

Shared Adapter | Model

Model of the Shared Adapter

Shared Adapter | Firmware Version

Firmware version of the Shared Adapter


Note


Port delta metrics are calculated based on Statistics Collection Interval specified in the Collection Policies.


UCS Manager Alerts in Operations Manager

The Operations Manager generates events based on the type of fault generated by the Cisco UCS Manager. The adapter generates system degradation events for each fault in Cisco UCS Manager. These events are used as symptoms to generate alerts in Operations Manager which can be viewed on the alerts widget on the UCSM Overview dashboard. The adapter supports all UCS Manager faults except the threshold faults, faults with info severity, FSM, or configuration type.

To view the details of an alert, double click an alert from the alerts list on the UCSM Overview dashboard. The alerts can also be viewed from the Alerts tab. You can view the details, such as the reason to generate alert, its impact on the UCS objects, and recommended actions to handle the alert.


Note


Although the faults cleared from the UCS Manager move to the inactive state, but they are stored and displayed in the vRealize alert widget. However, you can customize the view to exclude inactive faults from the display.

With the alerts generated for UCS Manager faults, the following alert is also generated:

  • Server Power State Change alerts

Server Power State Change Alerts

A server power state change alert is generated when the power state of the UCS server changes from healthy to unhealthy state. For example, when the power state is changed from On to Off state, then an alert is generated. The UCS server is considered as healthy when the power state of the server is either On, Off, or OK. Any other power state is considered as unhealthy state.

Displaying Relationship Between Physical and Virtual Infrastructure

Operations Manager displays the relationship between the UCS server and the ESXi hosts managed by the vCenter.

If you create an adapter instance for the UCS domain containing the blade or rack servers running the ESXi hosts, it automatically correlates the service profiles associated with the blades to the ESXi hosts. Also, it establishes a parent-child relationship between the service profile and the ESXi hosts.

This provides a view of the complete virtual and physical infrastructure in the relationship widget. Also, enables you to analyze the impact of the UCS component health on the virtual infrastructure running on it.

Using the Cisco UCS Manager Adapter

Cisco UCS Management Pack Dashboards

Once you deploy the Cisco UCS Management Pack adapter, the following dashboards are displayed in the vRealize Operations Manager. From these dashboards, you can monitor all the resources discovered by the adapter.

  • UCSM Overview

  • UCS Health Tree

  • UCS Fabric Interconnect Traffic Statistics

  • UCS Power and Temperature Summary

  • UCS Server Motherboard Statistics


Note


For the release version vROps 8.6 and later, to view the dashboards, navigate to Visualize > Dashboards.


UCSM Overview

The UCSM Overview dashboard comprises the following widgets:

  • Registered UCS domain—Displays the list of UCS domains which are configured for monitoring

  • UCS Domain Relationship—Displays the resources which are monitored, parent-child relationship, and faults associated with the selected resource

  • UCS Alert—Displays the alerts related to all resources or each resource when selected

  • Top 10 Blades by Consumed Power (W)—Displays the list of top ten blades depending on its power consumption

  • Top 10 Chassis by Consumed Power (W)—Displays the list of top ten chassis depending on its power consumption

  • Heatmap—Displays all the UCS objects, colored by health and sized by risk

  • Environment Status—Displays collective state of the UCS object

UCS Health Tree

The UCS Health Tree dashboard comprises the following widgets:

  • Environment Overview—Displays the parent-child view of the selected resource

  • Object Relationship—Displays the hierarchical view of the selected resource

UCS Fabric Interconnect Traffic Statistics

The UCS Fabric Interconnect Traffic Statistics dashboard comprises the following widgets:

  • FI Port Relationship—Displays all FI ports and port channels in a hierarchical view

  • Metric Picker—Displays supported metrics for the selected FI port or port channel

  • Metric Graph—Displays information related to the selected metric in a graphical view

UCS Power and Temperature Summary

The UCS Power and Temperature Summary dashboard comprises the following widgets:

  • Health Chart—Displays information related to the UCS server, chassis, fabric extender, and fabric interconnect

  • Metric Picker—Displays supported metrics for the selected resource

  • Metric Graph—Displays information related to the selected metric in a graphical view

  • UCS Alerts—Displays the faults related to all resources or each resource when selected

  • Metric Sparklines—Displays the metric key data in sparkline view

UCS Server Motherboard Statistics

The UCS Server Motherboard Statistics dashboard comprises the following widgets:

  • Health Chart—Displays information related to the UCS server

  • Metric Picker—Displays supported metrics for the selected resource

  • Metric Graph—Displays information related to selected metric in a graphical view

  • UCS Alerts—Displays the faults related to all resources or each resource when selected

  • Metric Sparklines—Displays the metric key data in sparkline view