Viewing
Sensors
This chapter includes the following sections:
- Viewing Power Supply Sensors
- Viewing Fan Sensors
- Viewing Temperature Sensors
- Viewing Voltage Sensors
- Viewing Current Sensors
- Viewing Storage Sensors
- Setting Dynamic Front Panel Temperature Threshold
Viewing Power Supply Sensors
| Command or Action | Purpose |
|---|
This example displays power supply sensor statistics:
Server# scope sensor
Server /sensor # show psu
Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure
------------ -------------- -------- ------ ------------ ------------ ------------- -------------
SU1_PIN Normal 102 Watts N/A 882 N/A 1098
PSU2_PIN Normal 96 Watts N/A 882 N/A 1098
PSU3_PIN Normal 102 Watts N/A 882 N/A 1098
PSU4_PIN Normal 96 Watts N/A 882 N/A 1098
PSU1_POUT Normal 78 Watts N/A 798 N/A 996
PSU2_POUT Normal 78 Watts N/A 798 N/A 996
PSU3_POUT Normal 84 Watts N/A 798 N/A 996
PSU4_POUT Normal 84 Watts N/A 798 N/A 996
POWER_USAGE Normal 406 Watts N/A N/A N/A 2674
PSU1_DC_OK Normal good
PSU2_DC_OK Normal good
PSU3_DC_OK Normal good
PSU4_DC_OK Normal good
PSU1_AC_OK Normal good
PSU2_AC_OK Normal good
PSU3_AC_OK Normal good
PSU4_AC_OK Normal good
PSU1_STATUS Normal present
PSU2_STATUS Normal present
PSU3_STATUS Normal present
PSU4_STATUS Normal present
Server /sensor # show psu-redundancy
Name Reading Sensor Status
-------------------- --------------- --------------------
PS_RDNDNT_MODE full Normal
Server /sensor #
Viewing Fan Sensors
| Command or Action | Purpose |
|---|
This example displays fan sensor statistics:
Server# scope sensor Server /sensor # show fan Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure --------------- ------------- ---------- ------ ------------- ------------ ------------- ------------ PSU1_FAN_SPEED Normal 5160 RPM 1118 N/A 946 N/A PSU2_FAN_SPEED Normal 6106 RPM 1118 N/A 946 N/A PSU3_FAN_SPEED Normal 5762 RPM 1118 N/A 946 N/A PSU4_FAN_SPEED Normal 4988 RPM 1118 N/A 946 N/A FAN1_SPEED Normal 6600 RPM 2040 N/A 1800 N/A FAN2_SPEED Normal 6660 RPM 2040 N/A 1800 N/A FAN3_SPEED Normal 6600 RPM 2040 N/A 1800 N/A FAN4_SPEED Normal 6660 RPM 2040 N/A 1800 N/A FAN5_SPEED Normal 6660 RPM 2040 N/A 1800 N/A FAN6_SPEED Normal 6660 RPM 2040 N/A 1800 N/A FAN7_SPEED Normal 6660 RPM 2040 N/A 1800 N/A FAN8_SPEED Normal 6660 RPM 2040 N/A 1800 N/A Server /sensor #
Viewing Temperature Sensors
| Command or Action | Purpose |
|---|
This example displays temperature sensor statistics:
Server# scope sensor Server /sensor # show temperature Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ IOH_TEMP_SENS Normal 32.0 C N/A 80.0 N/A 85.0 P2_TEMP_SENS Normal 31.0 C N/A 80.0 N/A 81.0 P1_TEMP_SENS Normal 34.0 C N/A 80.0 N/A 81.0 DDR3_P2_D1_TMP Normal 20.0 C N/A 90.0 N/A 95.0 DDR3_P1_A1_TMP Normal 21.0 C N/A 90.0 N/A 95.0 FP_AMBIENT_TEMP Normal 28.0 C N/A 40.0 N/A 45.0 Server /sensor #
Viewing Voltage Sensors
| Command or Action | Purpose |
|---|
This example displays voltage sensor statistics:
Server# scope sensor Server /sensor # show voltage Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ P3V_BAT_SCALED Normal 3.022 V N/A N/A 2.798 3.088 P12V_SCALED Normal 12.154 V N/A N/A 11.623 12.331 P5V_SCALED Normal 5.036 V N/A N/A 4.844 5.157 P3V3_SCALED Normal 3.318 V N/A N/A 3.191 3.381 P5V_STBY_SCALED Normal 5.109 V N/A N/A 4.844 5.157 PV_VCCP_CPU1 Normal 0.950 V N/A N/A 0.725 1.391 PV_VCCP_CPU2 Normal 0.891 V N/A N/A 0.725 1.391 P1V5_DDR3_CPU1 Normal 1.499 V N/A N/A 1.450 1.548 P1V5_DDR3_CPU2 Normal 1.499 V N/A N/A 1.450 1.548 P1V1_IOH Normal 1.087 V N/A N/A 1.068 1.136 P1V8_AUX Normal 1.773 V N/A N/A 1.744 1.852 Server /sensor #
Viewing Current Sensors
| Command or Action | Purpose |
|---|
This example displays current sensor statistics:
Server# scope sensor Server /sensor # show current Name Sensor Status Reading Units Min. Warning Max. Warning Min. Failure Max. Failure ------------------------- -------------- ---------- ---------- ------------ ------------ ------------ ------------ VR_P2_IMON Normal 16.00 AMP N/A 147.20 N/A 164.80 VR_P1_IMON Normal 27.20 AMP N/A 147.20 N/A 164.80 Server /sensor #
Viewing Storage Sensors
| Command or Action | Purpose |
|---|
Name column
The name
of the storage device.
Status column
A brief
description of the storage device status.
LED Status column
The
current LED color, if any.
To make
the physical LED on the storage device blink, select
Turn On from the drop-down list. To let the storage
device control whether the LED blinks, select
Turn Off.
This
information is only available for some C-Series servers.
Name
Description
Note
This example displays storage sensor information:
Server# scope chassis Server /chassis # show hdd Name Status -------------------- -------------------- HDD_01_STATUS present HDD_02_STATUS present HDD_03_STATUS present HDD_04_STATUS present Server /chassis #
Setting Dynamic Front Panel Temperature Threshold
Log in as a user with admin privileges.
This example shows how to set the dynamic front panel temperature threshold:
Server # scope sensor
Valid value for "fp-critical-temp" is from 8 to 50
Server /sensor # set fp-critical-temp 44
Server /sensor *# commit
Server /sensor # show temperature
Name Sensor Status Reading Units Critical Min Critical Max Non-Recoverable Min Non-Recoverable Max
------------------- ------------- ------- ------ ------------ ------------ -------------------- -------------------
VIC_SLOT1_TEMP Normal 58.0 C N/A 90.0 N/A 95.0
TEMP_SENS_FRONT Normal 27.0 C N/A 40.0 N/A 50.0
DDR4_P1_A1_TMP Normal 29.0 C N/A 85.0 N/A 90.0
DDR4_P2_G1_TMP Normal 28.0 C N/A 85.0 N/A 90.0
P1_TEMP_SENS Normal 39.5 C N/A 103.0 N/A 113.0
P2_TEMP_SENS Normal 39.5 C N/A 103.0 N/A 113.0
PSU1_TEMP Normal 27.0 C N/A 65.0 N/A 70.0
PSU2_TEMP Normal 26.0 C N/A 65.0 N/A 70.0
PCH_TEMP_SENS Normal 36.0 C N/A 85.0 N/A 90.0
RISER2_INLET_TMP Normal 37.0 C N/A 70.0 N/A 80.0
RISER1_INLET_TMP Normal 36.0 C N/A 70.0 N/A 80.0