Viewing Server Properties

This chapter includes the following sections:

Viewing Server Properties

Procedure
     Command or ActionPurpose
    Step 1Server # scope chassis  

    Enters chassis command mode.

     
    Step 2Server /chassis # scope server {1 | 2}  

    Enters server command mode of server 1 or 2.

     
    Step 3Server /chassis /server # show detail  

    Displays server properties.

     

    This example displays server properties:

    Server# scope chassis 
    Server /chassis #scope server 1 
    Server /chassis /Server #show 
    Server ID Power Serial Number Product Name  PID              UUID                                 
    --------- ----- ------------- ------------- ---------------- ------------------------------------ 
    2         on    FCH183978RD   UCS C3260     UCSC-C3X60-SVRNB 207BD0D4-C589-40C1-A73E-EF6E7F773198 
    
    Server /chassis /Server #show detail
    Server ID 1:
        Power: off
        Serial Number: FCH1848794D
        Product Name: UCS C3260
        PID: UCSC-C3X60-SVRNB
        UUID: 60974271-A514-484C-BAE3-A5EE4FD16E06
     Server /chassis /Server #  
    

    Viewing CMC Properties

    Procedure
       Command or ActionPurpose
      Step 1server # scope chassis  

      Enters chassis command mode.

       
      Step 2server /chassis # scope cmc 1|2  

      Enters CMC on the chosen SIOC controller command mode.

       
      Step 3server /chassis/cmc # show detail  

      Displays the CMC details for the chosen SIOC controller.

       

      This example shows how to view the CMC details:

      server # scope chassis
      server /chassis # scope cmc 1
      server /chassis/cmc # show detail
      CMC Firmware update initialized.
      Please check the status using "show detail"
      Server /chassis/cmc # show detail
      Firmware Image Information:
          ID: 1
          Name: CMC1
          Serial Number: FCH19117MTU
          Update Stage: NONE
          Update Progress: 100
          Current FW Version: 2.0(10.97)
          FW Image 1 Version: 2.0(10.97)
          FW Image 1 State: RUNNING ACTIVATED
          FW Image 2 Version: 2.0(10.87)
          FW Image 2 State: BACKUP INACTIVATED
          Reset Reason: not-applicable (This provides the reason for the last Cisco IMC reboot.)
      server /chassis/cmc # 

      Viewing Server CPU Details

      Procedure
         Command or ActionPurpose
        Step 1Server # scope chassis  

        Enters chassis command mode.

         
        Step 2Server /chassis # scope server {1 | 2}  

        Enters server command mode of server 1 or 2.

         
        Step 3Server /chassis /server # show cpu  

        Displays CPU details for the server.

         
        Step 4Server# show cpu-pid   Displays the CPU product IDs .  

        This example displays the CPU details for the server:

        Server# scope chassis 
        Server /chassis #scope server 1 
        Server /chassis /Server #show cpu
        Name         Cores    Version                                            
        ------------ -------- -------------------------------------------------- 
        CPU1         6        Intel(R) Xeon(R) CPU E5-2620 v2 @ 2.10GHz          
        CPU2         6        Intel(R) Xeon(R) CPU E5-2620 v2 @ 2.10GHz  
        
        Server /chassis /Server #show cpu-pid
        Socket Product ID           Model                                    
        ------ -------------------- ---------------------------------------- 
        CPU1   UCS-CPU-E52620B      Intel(R) Xeon(R) CPU E5-2620 v2 @ 2.1... 
        CPU2   UCS-CPU-E52620B      Intel(R) Xeon(R) CPU E5-2620 v2 @ 2.1... 
        
         Server /chassis /Server #  
        

        Viewing Memory Properties

        Procedure
           Command or ActionPurpose
          Step 1Server # scope chassis  

          Enters chassis command mode.

           
          Step 2Server /chassis # scope server {1 | 2}  

          Enters server command mode of server 1 or 2.

           
          Step 3Server /chassis /server # show dimm  

          Displays DIMM details for the server.

           
          Step 4Server# show dimm-pid   Displays the DIMM product IDs.  
          Step 5Server# show dimm-summary   Displays the DIMM summary information .  

          This example displays the DIMM details for the server.:

          Server# scope chassis 
          Server /chassis #scope server 1 
          Server /chassis /Server #show dimm
          Name                 Capacity        Channel Speed (MHz) Channel Type    
          -------------------- --------------- ------------------- --------------- 
          DIMM_A1              16384 MB        1866                DDR3            
          DIMM_A2              16384 MB        1866                DDR3            
          DIMM_B1              16384 MB        1866                DDR3            
          DIMM_B2              16384 MB        1866                DDR3            
          DIMM_C1              16384 MB        1866                DDR3            
          DIMM_C2              16384 MB        1866                DDR3            
          DIMM_D1              16384 MB        1866                DDR3            
          DIMM_D2              16384 MB        1866                DDR3            
          DIMM_E1              16384 MB        1866                DDR3            
          DIMM_E2              16384 MB        1866                DDR3            
          DIMM_F1              16384 MB        1866                DDR3            
          DIMM_F2              16384 MB        1866                DDR3            
          DIMM_G1              16384 MB        1866                DDR3            
          DIMM_G2              16384 MB        1866                DDR3            
          DIMM_H1              16384 MB        1866                DDR3            
          DIMM_H2              16384 MB        1866                DDR3  
          
          Server /chassis /Server #show dimm-pid
          Name              Product ID           Vendor ID  Capacity  Speed  
          ----------------- -------------------- ---------- --------- ------ 
          DIMM_A1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_A2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_B1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_B2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_C1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_C2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_D1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_D2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_E1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_E2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_F1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_F2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_G1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_G2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_H1           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          DIMM_H2           UCS-MR-1X162RZ-A     0xCE00     16384 MB  1866   
          
          Server /chassis /Server #show dimm-summary
          DIMM Summary:
              Memory Speed: 1600 MHz
              Total Memory: 262144 MB
              Effective Memory: 262144 MB
              Redundant Memory: 0 MB
              Failed Memory: 0 MB
              Ignored Memory: 0 MB
              Number of Ignored Dimms: 0
              Number of Failed Dimms: 0
              Memory RAS possible: Independent Mirroring Lockstep
              Memory Configuration: Independent
          
          
           Server /chassis /Server #  
          

          Viewing PCI Adapter Properties for a Server

          Procedure
             Command or ActionPurpose
            Step 1Server # scope chassis  

            Enters chassis command mode.

             
            Step 2Server /chassis # scope server {1 | 2}  

            Enters server command mode of server 1 or 2.

             
            Step 3Server /chassis /server # show pci-adapter  

            Displays PCI adapter details for the server.

             
            Step 4Server# show pciadapter-pid   Displays the PCI adapter product IDs.  

            This example displays the PCI adapter details for the server.:

            Server# scope chassis 
            Server /chassis #scope server 1 
            Server /chassis /Server #show pci-adapter
            Slot       Vendor ID  Device ID  SubVendor ID  SubDevice ID  Firmware Version Product Name              
            ---------- ---------- ---------- ------------- ------------- ------------- ------------------------- 
            1          0x1137     0x0042     0x1137        0x0157        4.0(300.71)   UCSC-C3260-SIOC           
            M          0x1000     0x005d     0x1137        0x012d        24.7.3-0006   Cisco RAID controller ... 
            
            Server /chassis /Server #show pciadapter-pid
            Slot   Product ID           Vendor ID  Device ID   SubVendor ID  SubDevice ID  
            ------ -------------------- ---------- ----------- ------------- ------------- 
            1      UNKNOWN              0x1137     0x0042      0x1137        0x0157        
            M      UCSC-C3X60-RAID      0x1000     0x005d      0x1137        0x012d    
             
             Server /chassis /Server #  
            

            Viewing HDD Details for a Server

            Procedure
               Command or ActionPurpose
              Step 1Server # scope chassis  

              Enters chassis command mode.

               
              Step 2Server /chassis # scope server {1 | 2}  

              Enters server command mode of server 1 or 2.

               
              Step 3Server /chassis /server # show hdd-pid  

              Displays HDD details for the server.

               

              This example displays the HDD details for the server:

              Server# scope chassis 
              Server /chassis #scope server 1 
              Server /chassis /Server #show hdd-pid
              Disk Controller  Product ID           Vendor     Model        
              ---- ----------- -------------------- ---------- ------------ 
              1    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              2    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              3    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              4    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              5    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              6    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              7    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              8    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              9    SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              10   SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              11   SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              12   SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              13   SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400   
              14   SLOT-MEZZ   UCS-HD4T7KS3-E       TOSHIBA    MG03SCA400  
              
               Server /chassis /Server#  
              

              Viewing Storage Adapter Properties for a Server

              Procedure
                 Command or ActionPurpose
                Step 1Server # scope chassis  

                Enters chassis command mode.

                 
                Step 2Server /chassis # scope server {1 | 2}  

                Enters server command mode of server 1 or 2.

                 
                Step 3Server /chassis /server # show storageadapter  

                Displays storage adapter details for the server.

                 

                This example displays the storage adapter details for the server.:

                Server# scope chassis 
                Server /chassis #scope server 1 
                Server /chassis /Server #show storageadapter
                PCI Slot     Health         Controller Status ROC Temperature Product Name                            
                ------------ -------------- ----------------- --------------- ----------------------------------    
                SLOT-MEZZ    Good           Optimal           48 degrees C    RAID controller for UCS C3X60 S...   
                          
                Serial Number   Firmware Package Build  Product ID  D Battery Status  Cache Memory Size
                --------------  ----------------------  ----------  ----------------  ----------------- 
                FCH184972F5      24.7.3-0006            LSI Logic   Optimal            3534 MB
                
                Boot Drive  Boot Drive is PD 
                ----------  -----------------
                 0           false
                 Server /chassis /Server #  
                

                Viewing TPM Properties

                Procedure
                   Command or ActionPurpose
                  Step 1Server # scope chassis  

                  Enters chassis command mode.

                   
                  Step 2Server /chassis # scope server {1 | 2}  

                  Enters server command mode of server 1 or 2.

                   
                  Step 3Server /chassis/server # show tpm-inventory  

                  Displays TPM properties for the server.

                   

                  This example displays the TPM properties for the server:

                  Server# scope chassis 
                  Server /chassis #scope server 1 
                  Server /chassis /Server #show tpm-inventory
                  Version     Presence     Enabled-Status     Active-Status     Ownership Revision             
                  ----------- ------------ ------------------ ----------------- --------- ------------  
                  NA          empty        unknown            unknown           unknown   NA   
                  
                  Model            Vendor               Serial   
                  ---------------- -------------------- ----------------
                  
                   Server chassis /Server#