Viewing Server Properties

This chapter includes the following sections:

Viewing Server Properties

Procedure
     Command or ActionPurpose
    Step 1Server# show chassis [detail]  

    Displays server properties.

     

    This example displays server properties:

    Server# show chassis detail
    Chassis:
        Power: on
        Serial Number: QCI140205ZG
        Product Name: UCS C210 M2
        PID : R210-2121605W
        UUID: FFFFFFFF-FFFF-FFFF-FFFF-FFFFFFFFFFFF
        Locator LED: off 
    				Description: This shows the chassis details.
        
    Server#  
    

    This example displays server properties for C3160 servers:

    Server# show chassis detail
    Chassis:
        Power: on
        Serial Number: FCH1821JAVL
        Product Name: UCS C3160
        PID : UCSC-C3X60-SVRNB
        UUID: 84312F76-75F0-4BD1-9167-28B74EBB444C
        Locator LED: off
        Front Panel Locator LED: off
        Description: This shows the chassis details
    Server#  
    

    Viewing a Server Utilization

    You can view a server utilization only on some UCS C-Series servers.

    Procedure
       Command or ActionPurpose
      Step 1Server# scope chassis  

      Enters the chassis command mode.

       
      Step 2Server /chassis # show cups-utilization  

      Displays the server utilization value on all the available CPUs.

      Note   

      These utilization values are reported as a percentage of the total hardware bandwidth. These values may not match with the values being displayed by the host based resource monitoring software.

       

      This example shows how to view the server utilization value:

      Server# scope chassis
      Server /chassis # show cups-utilization 
      
      CPU Utilization (%)  Memory Utilization (%)  I/O Utilization (%)  Overall Utilization (%)
      -------------------- ----------------------- -------------------- ------------------------
      100                  69                      0                    86
      
      Server /chassis # 
      

      Viewing Cisco IMC Properties


      Note


      Cisco IMC gets the current date and time from the server BIOS. To change this information, reboot the server and press F2 when prompted to access the BIOS configuration menu. Then change the date or time using the options on the main BIOS configuration tab.


      Procedure
         Command or ActionPurpose
        Step 1Server# show cimc [detail]  

        Displays Cisco IMC properties.

         

        This example displays Cisco IMC properties:

        Server# show cimc detail
        Cisco IMC:
            Firmware Version: 2.0(8.122)
            Current Time: Wed Dec  9 23:14:28 2015
            Boot-loader Version: 2.0(8.122).36
            Local Time: Wed Dec  9 23:14:28 2015 UTC +0000
            Timezone: UTC
            Reset Reason: graceful-reboot (This provides the last Cisco IMC reboot reason.)
        
        Server#  
        

        Viewing CPU Properties

        Before You Begin

        The server must be powered on, or the properties will not display.

        Procedure
           Command or ActionPurpose
          Step 1Server# scope chassis  

          Enters chassis command mode.

           
          Step 2Server /chassis # show cpu [detail]  

          Displays CPU properties.

           

          This example displays CPU properties:

          Server# scope chassis
          Server /chassis # show cpu
          Name         Cores    Version                                            
          ------------ -------- -------------------------------------------------- 
          CPU1         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
          CPU2         4        Intel(R) Xeon(R) CPU           E5520  @ 2.27GHz    
          
          Server /chassis #  
          

          Viewing Memory Properties

          Before You Begin

          The server must be powered on, or the properties will not display.

          Procedure
             Command or ActionPurpose
            Step 1Server# scope chassis  

            Enters chassis command mode.

             
            Step 2Server /chassis # show dimm [detail]  

            Displays memory properties.

             
            Step 3Server /chassis # show dimm-summary  

            Displays DIMM summary information.

             

            This example displays memory properties:

            Server# scope chassis
            Server /chassis # show dimm
            Name                 Capacity        Channel Speed (MHz) Channel Type    
            -------------------- --------------- ------------------- --------------- 
            DIMM_A1              2048 MB         1067                Other           
            DIMM_A2              2048 MB         1067                Other           
            DIMM_B1              2048 MB         1067                Other           
            DIMM_B2              2048 MB         1067                Other           
            DIMM_C1              Not Installed   Unknown             Other           
            DIMM_C2              Not Installed   Unknown             Other           
            DIMM_D1              2048 MB         1067                Other           
            DIMM_D2              2048 MB         1067                Other           
            DIMM_E1              2048 MB         1067                Other           
            DIMM_E2              2048 MB         1067                Other           
            DIMM_F1              Not Installed   Unknown             Other           
            DIMM_F2              Not Installed   Unknown             Other           
            
            Server /chassis # 
            

            This example displays detailed information about memory properties:

            Server# scope chassis
            Server /chassis # show dimm detail
            Name DIMM_A1:
                Capacity: 2048 MB
                Channel Speed (MHz): 1067
                Channel Type: Other
                Memory Type Detail: Synchronous
                Bank Locator: NODE 0 CHANNEL 0 DIMM 0
                Visibility: Yes
                Operability: Operable
                Manufacturer: 0x802C
                Part Number: 18JSF25672PY-1G1D1
                Serial Number: 0xDA415F3F
                Asset Tag: Unknown
                Data Width: 64 bits
            Name DIMM_A2:
                Capacity: 2048 MB
            --More--   
            
            Server /chassis # 
            

            This example displays DIMM summary information:

            Server# scope chassis
            Server /chassis # show dimm-summary
            DIMM Summary:
                Memory Speed: 1067 MHz
                Total Memory: 16384 MB
                Effective Memory: 16384 MB
                Redundant Memory: 0 MB
                Failed Memory: 0 MB
                Ignored Memory: 0 MB
                Number of Ignored Dimms: 0
                Number of Failed Dimms: 0
                Memory RAS possible: Memory configuration can support mirroring
                Memory Configuration: Maximum Performance
            
            Server /chassis # 
            

            Viewing Power Supply Properties

            Before You Begin

            The server must be powered on, or the properties will not display.

            Procedure
               Command or ActionPurpose
              Step 1Server# scope chassis  

              Enters chassis command mode.

               
              Step 2Server /chassis # show psu [detail]  

              Displays power supply properties.

               

              This example displays power supply properties:

              Server# scope chassis
              Server /chassis # show psu
              Name       In. Power (Watts)    Out. Power (Watts)   Firmware  Status     
              ---------- -------------------- -------------------- -------- ---------- 
              PSU1       74                   650                  R0E      Present    
              PSU2       83                   650                  R0E      Present    
              
              Server /chassis #  
              

              Note


              Input Power and Maximum Output Power options are available only for some C-Series servers.


              Viewing Storage Properties

              Viewing Storage Adapter Properties

              Before You Begin

              The server must be powered on, or the properties will not display.

              Procedure
                 Command or ActionPurpose
                Step 1Server# scope chassis  

                Enters the chassis command mode.

                 
                Step 2Server /chassis # show storageadapter [slot] [detail]  

                Displays installed storage cards.

                Note   

                This command displays all MegaRAID controllers on the server that can be managed through Cisco IMC. If an installed controller or storage device is not displayed, then it cannot be managed through Cisco IMC.

                 
                Step 3Server /chassis # scope storageadapter slot  

                Enters command mode for an installed storage card.

                 
                Step 4Server /chassis/storageadapter # show bbu [detail]  

                Displays battery backup unit information for the storage card.

                 
                Step 5Server /chassis/storageadapter # show capabilites [detail]  

                Displays RAID levels supported by the storage card.

                 
                Step 6Server /chassis/storageadapter # show error-counters [detail]  

                Displays number of errors seen by the storage card.

                 
                Step 7Server /chassis/storageadapter # show firmware-versions [detail]  

                Displays firmware version information for the storage card.

                 
                Step 8Server /chassis/storageadapter # show hw-config [detail]  

                Displays hardware information for the storage card.

                 
                Step 9Server /chassis/storageadapter # show mfg-data [detail]  

                Displays manufacturer data for the storage card.

                 
                Step 10Server /chassis/storageadapter # show pci-info [detail]  

                Displays adapter PCI information for the storage card.

                 
                Step 11Server /chassis/storageadapter # show running-firmware-images [detail]  

                Displays running firmware information for the storage card.

                 
                Step 12Server /chassis/storageadapter # show settings [detail]  

                Displays adapter firmware settings for the storage card.

                 
                Step 13Server /chassis/storageadapter # show startup-firmware-images [detail]  

                Displays firmware images to be activated on startup for the storage card.

                 

                This example displays storage properties:

                Server# scope chassis
                Server /chassis # show storageadapter
                PCI Slot Product Name                       Serial Number  Firmware Package Build    
                -------- ---------------------------------- -------------- ------------------------- 
                SAS      LSI MegaRAID SAS 9260-8i           SV93404392     12.12.0-0038                      
                
                          Product ID     Battery Status Cache Memory Size 
                     ---- -------------- -------------- -------------- 
                          LSI Logic      fully charged  0 MB           
                
                Server /chassis #             
                

                This example displays battery backup unit information for the storage card named SAS:

                Server# scope chassis
                Server /chassis # scope storageadapter SAS
                Server /chassis/storageadapter # show bbu
                Controller Battery Type Battery Present Voltage    Current    Charge Charging State 
                ---------- ------------ --------------- ---------- ---------- ------ -------------- 
                SAS        iBBU         true            4.051 V    0.000 A    100%   fully charged  
                
                Server /chassis/storageadapter #             
                

                Viewing the Flexible Flash Controller Properties

                Before You Begin
                • Cisco Flexible Flash must be supported by your platform.

                Procedure
                   Command or ActionPurpose
                  Step 1Server# scope chassis  

                  Enters the chassis command mode.

                   
                  Step 2Server /chassis # show flexflash [detail]  

                  (Optional) Displays the available Cisco Flexible Flash controllers.

                   
                  Step 3Server /chassis # scope flexflash index  

                  Enters the Cisco Flexible Flash controller command mode for the specified controller. At this time, the only permissible index value is FlexFlash-0.

                   
                  Step 4Server /chassis/flexflash # show operational-profile [detail] 

                  Displays the operational profile properties.

                   

                  This example displays the properties of the flash controller:

                  Server# scope chassis
                  Server /chassis # show flexflash
                  Controller   Product Name     Has Error  Firmware Version  Vendor   Internal State
                  ------------ ---------------- ---------- ----------------- -------- ---------------
                  FlexFlash-0  Cisco FlexFlash  No         1.2 build 247     Cypress  Connected    
                  
                  Server /chassis # scope flexflash FlexFlash-0
                  Server /chassis # show operational-profile
                  Primary Member Slot  I/O Error Threshold  Host Accessible VDs  
                  -------------------- -------------------- -------------------- 
                  slot1                100                  SCU Drivers  
                  
                  Server /chassis/flexflash #
                  

                  Viewing Physical Drive Properties

                  Procedure
                     Command or ActionPurpose
                    Step 1Server# scope chassis  

                    Enters the chassis command mode.

                     
                    Step 2Server /chassis # scope storageadapter slot  

                    Enters command mode for an installed storage card.

                     
                    Step 3Server /chassis/storageadapter # show physical-drive [drive-number] [detail]  

                    Displays physical drive information for the storage card.

                     
                    Step 4Server /chassis/storageadapter # show physical-drive-count [detail]  

                    Displays the number of physical drives on the storage card.

                     
                    Step 5Server /chassis/storageadapter # scope physical-drive drive-number  

                    Enters command mode for the specified physical drive.

                     
                    Step 6Server /chassis/storageadapter/physical-drive # show general [detail]  

                    Displays general information about the specified physical drive.

                     
                    Step 7Server /chassis/storageadapter/physical-drive # show inquiry-data [detail]  

                    Displays inquiry data about the specified physical drive.

                     
                    Step 8Server /chassis/storageadapter/physical-drive # show status [detail]  

                    Displays status information about the specified physical drive.

                     

                    This example displays general information about physical drive number 1 on the storage card named SAS:

                    Server# scope chassis
                    Server /chassis # scope storageadapter SAS
                    Server /chassis/storageadapter # scope physical-drive 1
                    Server /chassis/storageadapter/physical-drive # show general
                    Slot Number 1:
                        Controller: SAS
                        Enclosure Device ID: 27
                        Device ID: 34
                        Sequence Number: 2
                        Media Error Count: 0
                        Other Error Count: 0
                        Predictive Failure Count: 0
                        Link Speed: 6.0 Gb/s
                        Interface Type: SAS
                        Media Type: HDD
                        Block Size: 512
                        Block Count: 585937500
                        Raw Size: 286102 MB
                        Non Coerced Size: 285590 MB
                        Coerced Size: 285568 MB
                        SAS Address 0: 500000e112693fa2
                        SAS Address 1: 
                        Connected Port 0: 
                        Connected Port 1: 
                        Connected Port 2: 
                        Connected Port 3: 
                        Connected Port 4: 
                        Connected Port 5: 
                        Connected Port 6: 
                        Connected Port 7: 
                        Power State: powersave
                    
                    Server /chassis/storageadapter/physical-drive #             
                    

                    This example displays inquiry data about physical drive number 1 on the storage card named SAS:

                    Server# scope chassis
                    Server /chassis # scope storageadapter SAS
                    Server /chassis/storageadapter # scope physical-drive 1
                    Server /chassis/storageadapter/physical-drive # show inquiry-data
                    Slot Number 1:
                        Controller: SAS
                        Product ID: MBD2300RC
                        Drive Firmware: 5701
                        Drive Serial Number: D010P9A0016D
                    
                    Server /chassis/storageadapter/physical-drive #             
                    

                    This example displays status information about physical drive number 1 on the storage card named SAS:

                    Server# scope chassis
                    Server /chassis # scope storageadapter SAS
                    Server /chassis/storageadapter # scope physical-drive 1
                    Server /chassis/storageadapter/physical-drive # show inquiry-data
                    Slot Number 1:
                        Controller: SAS
                        State: online
                        Online: true
                        Fault: false
                    
                    Server /chassis/storageadapter/physical-drive #             
                    

                    Viewing Virtual Drive Properties

                    Procedure
                       Command or ActionPurpose
                      Step 1Server# scope chassis  

                      Enters the chassis command mode.

                       
                      Step 2Server /chassis # scope storageadapter slot  

                      Enters command mode for an installed storage card.

                       
                      Step 3Server /chassis/storageadapter # show virtual-drive [drive-number] [detail]  

                      Displays virtual drive information for the storage card.

                       
                      Step 4Server /chassis/storageadapter # show virtual-drive-count [detail]  

                      Displays the number of virtual drives configured on the storage card.

                       
                      Step 5Server /chassis/storageadapter # scope virtual-drive drive-number  

                      Enters command mode for the specified virtual drive.

                       
                      Step 6Server /chassis/storageadapter/virtual-drive # show physical-drive [detail]  

                      Displays physical drive information about the specified virtual drive.

                       

                      This example displays information about virtual drives on the storage card named SAS:

                      Server# scope chassis
                      Server /chassis # scope storageadapter SAS
                      Server /chassis/storageadapter # show virtual-drive
                      Virtual Drive  Status          Name                     Size       RAID Level 
                      -------------- --------------- ------------------------ ---------- ---------- 
                      0              Optimal         SLES1SP1beta5            30720 MB   RAID 0     
                      1              Optimal         RHEL5.5                  30720 MB   RAID 0     
                      2              Optimal         W2K8R2_DC                30720 MB   RAID 0     
                      3              Optimal         VD_3                     30720 MB   RAID 0     
                      4              Optimal         ESX4.0u2                 30720 MB   RAID 0     
                      5              Optimal         VMs                      285568 MB  RAID 0     
                      6              Optimal         RHEL6-35GB               35840 MB   RAID 0     
                      7              Optimal         OS_Ins_Test_DR           158720 MB  RAID 0     
                      8              Optimal                                  285568 MB  RAID 1        
                      
                      Server /chassis/storageadapter #             
                      

                      This example displays physical drive information about virtual drive number 1 on the storage card named SAS:

                      Server# scope chassis
                      Server /chassis # scope storageadapter SAS
                      Server /chassis/storageadapter # scope virtual-drive 1
                      Server /chassis/storageadapter/virtual-drive # show physical-drive
                      Span  Physical Drive Status     Starting Block Number Of Blocks 
                      ----- -------------- ---------- -------------- ---------------- 
                      0     12             online     62914560       62914560         
                      
                      Server /chassis/storageadapter/virtual-drive #             
                      

                      Viewing Nvidia GPU Card Information

                      These commands are not available on all UCS C-series servers.

                      Before You Begin

                      The server must be powered on to view information on the Nvidia GPU cards.

                      Procedure
                         Command or ActionPurpose
                        Step 1Server# scope chassis  

                        Enters the chassis command mode.

                         
                        Step 2Server /chassis # show gpu 

                        Displays the available Nvidia GPU cards on the system.

                         
                        Step 3Server /chassis # scope gpu slot-number 

                        Enters the GPU card command mode. Specify the slot number of the GPU card.

                         
                        Step 4Server /chassis/gpu # show gpu-list 

                        Displays temperature information on the GPU cards.

                         

                        This example shows how to view the temperature information of the available GPU cards on the system:

                        Server # scope chassis
                        Server /chassis # show gpu
                        
                        Slot       Product Name         Num of GPUs
                        ----       ------------         -----------
                        5          Nvidia GRID K2 @ BD     2
                        
                        Server /chassis # scope gpu 5
                        Server /chassis/gpu # show gpu-list
                        
                        GPU ID       Temperature
                        ------       -----------
                        0             32
                        1             33
                        
                        Server /chassis/gpu # 

                        Viewing PCI Adapter Properties

                        Before You Begin

                        The server must be powered on, or the properties will not display.

                        Procedure
                           Command or ActionPurpose
                          Step 1Server# scope chassis  

                          Enters the chassis command mode.

                           
                          Step 2Server /chassis # show pci-adapter [detail]  

                          Displays PCI adapter properties.

                           

                          This example displays PCI adapter properties:

                          Server# scope chassis
                          Server /chassis # show pci-adapter
                          Slot Vendor ID Device ID  SubVendor ID SubDevice ID  Firmware Version Product Name
                          ---- --------- ---------- ------------ ------------- ---------------- -------------------
                          L    0x8086    0x1521     0x1137        0x008b        0x80000AA5... Intel(R) I350 1 Gbps N...
                          1    0x19a2    0x0710     0x10df        0xe702        4.6.142.10    Emulex OCe11102-FX 2 p...
                          3    0x10de    0x118f     0x10de        0x097f        N/A           Nvidia TESLA K10 P2055...
                          4    0x14e4    0x1639     0x14e4        0x1639        N/A           Broadcom 5709 1 Gbps 2...
                          5    0x10de    0x0ff2     0x10de        0x1012        N/A           Nvidia GRID K1 P2401-502
                          M    0x1000    0x0073     0x1137        0x00b1        N/A           Cisco UCSC RAID SAS 20…
                          
                          Server /chassis # 
                          

                          Viewing Network Related Properties

                          Viewing LOM Properties

                          You can view the MAC addresses of the LAN On Motherboard (LOM) Ethernet ports.

                          Procedure
                             Command or ActionPurpose
                            Step 1Server# scope chassis  

                            Enters the chassis command mode.

                             
                            Step 2Server /chassis # scope network-adapter slot ID  

                            Enters the specific network adapter command mode.

                             
                            Step 3Server /chassis/network-adapter # show mac-list [detail]  

                            Displays the MAC addresses of the LOM ports.

                             

                            This example shows how to display the MAC addresses of the LOM ports:

                            Server# scope chassis
                            Server /chassis # scope network-adapter L
                            Server /chassis/network-adapter # show mac-list
                            Interface ID       MAC Address
                            -------------  --------------------
                            eth0            010000002000
                            eth1            010000002000
                            
                            Server /chassis/network-adapter # 
                            

                            Viewing TPM Properties

                            Before You Begin

                            The server must be powered on, or the properties will not display.

                            Procedure
                               Command or ActionPurpose
                              Step 1Server# scope chassis  

                              Enters the chassis command mode.

                               
                              Step 2Server /chassis # show tpm-inventory  

                              Displays the TPM properties.

                               

                              This example displays the TPM properties:

                              Server# scope chassis
                              Server /chassis # show tpm-inventory
                              
                              Version Presence  Enabled-Status  Active-Status  Ownership  Revision     Model         Vendor      Serial
                              ------- --------  --------------  -------------- ---------- ---------  -------------   --------   -----------
                               A      equipped    disabled       deactivated    unowned      1       UCSX-TPMX-00X   ABC Inc    FCHXXXXXXXX
                              
                              Server /chassis #