Examples of Common Server Management Tasks
The examples in this chapter show how to use the Cisco IMC XML API to perform common server management tasks. Each example shows the XML API request followed by the response from Cisco IMC.
This chapter includes the following examples:
-
Using Cisco IMC LDAP User Credentials to Establish XML API Session Cookie
-
Retrieving Current Running Firmware Versions of Server Components
-
Using the inHierarchical Option to Retrieve Configured Boot Order Table
-
Configuring EFI as the Second Boot Device in Boot Order Table
-
Removing Floppy Disk Drive as a Boot Device From the Boot Order List
-
Configuring Boot Order to HDD, CDROM, FDD, PXE, and EFI Without Rebooting the Host
-
Using inHierarchical Option to Change and Retrieve SNMP Configuration of Trap Receivers
-
Using Platform-Default to Configure BIOS Parameters to Default Values
-
Using Non-Interactive HUU to Update Firmware on all C-Series Server Components
-
Retrieving MAC Address of Individual Ports of Network Controllers
-
Retrieving LSI Storage Adapter Summary Properties Installed on C-Series Server
-
Retrieving LSI Storage Adapter Detailed Properties Installed on C-Series Server
-
Retrieving Details of All Virtual Drives Configured in LSI Adapters
-
Retrieving Details of Physical Disks Usage by Virtual Drives
-
Setting up ID 11 Cisco IMC User With Username and Password and Enabling Login Access to this User
-
Generating Temporary Authentication Tokens and Launching the KVM
-
Triggering Snapshot based on Parameters Provided with Request
-
Configuring BIOS Parameters Across Various Platforms Using a Master XML Request
-
Configuring Network Port Speed and Duplex With Auto-negotiation in Disabled State
Using Cisco IMC LDAP User Credentials to Establish XML API Session Cookie
Request:
<aaaLogin inName='admin' inPassword='cisco@123'/>
Response:
<aaaLogin cookie="" response="yes" outCookie="1461753405/e60c76e8-3175-1175-8002-4cc92474a254"
outRefreshPeriod="600" outPriv="admin"
outSessionId="17" outVersion="3.0(0.149)">
</aaaLogin>
Retrieving Cisco IMC User Sessions
Request:
<configResolveClass cookie='1385080136/1a887a90-ebb9-1bb9-8007-130bcc74a254'
classId='aaaSession' inHierarchical='true'>
</configResolveClass>"
Response:
<configResolveClass cookie="1385080136/1a887a90-ebb9-1bb9-8007-130bcc74a254"
response="yes" classId="aaaSession">
<outConfigs>
<aaaSession host="10.10.10.10" id="18" ui="shell" user="admin"
dn="sys/user-ext/term-18" ></aaaSession>
<aaaSession host="10.10.10.10" id="17" ui="web" user="admin"
dn="sys/user-ext/term-17" ></aaaSession>
<aaaSession host="N/A" id="15" ui="serial" user="admin"
dn="sys/user-ext/term-15" ></aaaSession>
<aaaSession host="10.10.10.10" id="9" ui="web" user="admin"
dn="sys/user-ext/term-9" >
</aaaSession>
</outConfigs>
</configResolveClass>
Note |
UI type indicates serial when you connect directly to the server through the serial port using either a KVM dongle (DB9), or the serial port (RJ-45) at the rear of the chassis. |
Retrieving Server Summary Information and Host Power State
Request:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="false" classId="computeRackUnit"/>
Response:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388" response="yes"
classId="computeRackUnit"/>
<outConfig>
<computeRackUnit dn="sys/rack-unit-1" adminPower="policy" availableMemory="49152"
model="R250-2480805W" memorySpeed="1067" name="UCS C250 M2" numOfAdaptors="1"
numOfCores="8" numOfCoresEnabled="8" numOfCpus="2" numOfEthHostIfs="8"
numOfFcHostIfs="2" numOfThreads="16" operPower="on"
originalUuid="100DC440-0EBC-11DF-3B97-8843E1C2615E" presence="equipped" serverId="1"
serial="PGS140601CS" totalMemory="49152" usrLbl="Cisco C250 Server"
uuid="100DC440-0EBC-11DF-3B97-8843E1C2615E" vendor="Cisco Systems Inc"
cimcResetReason="graceful-reboot />
</outConfig>
</configResolveClass>
Retrieving Current Running Firmware Versions of Server Components
Request:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="false" classId="firmwareRunning"/>
Response:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388" response="yes"
classId="firmwareRunning">
<outConfigs>
<firmwareRunning dn="sys/rack-unit-1/bios/fw-boot-loader" deployment="boot-loader"
type="blade-bios" version="CxxMx.1.5.1c.0 (Build Date: 01/31/2013)" >
<firmwareRunning dn="sys/rack-unit-1/mgmt/fw-boot-loader" deployment="boot-loader"
type="blade-controller" version="1.5(0.59).24"
<firmwareRunning dn="sys/rack-unit-1/mgmt/fw-system"
deployment="system" type="blade-controller" version="1.5(1b)" >
<firmwareRunning dn="sys/rack-unit-1/board/storage-SAS-SLOT-4/fw-boot-loader"
deployment="boot-loader" type="storage-controller"
version="4.31.00_4.12.05.00_0x05180000" >
<firmwareRunning dn="sys/rack-unit-1/board/storage-SAS-SLOT-4/fw-system"
deployment="system" type="storage-controller" version="2.130.364-2185" >
</firmwareRunning>
</outConfigs>
</configResolveClass>
Retrieving Backup Firmware Version Installed on Cisco IMC
Request:
<configResolveDn cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="false" dn="sys/rack-unit-1/mgmt/fw-updatable"/>
Response:
<configResolveDn cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388" response="yes"
dn="sys/rack-unit-1/mgmt/fw-updatable">
<outConfig>
<firmwareUpdatable dn="sys/rack-unit-1/mgmt/fw-updatable" adminState="triggered"
deployment="backup" operState="ready" version="1.5(0.73)" protocol="none"
remoteServer="" remotePath="" user="" pwd="" progress="Success"
type="blade-controller">
</outConfig>
</configResolveDn>
Activating Firmware Backup Image on Cisco IMC
Request:
<configConfMo cookie='1369391866/63bd7c70-dd74-1d74-8002-233362a70344'
dn='sys/rack-unit-1/mgmt/fw-boot-def/bootunit-combined'>
<inConfig>
<firmwareBootUnit dn='sys/rack-unit-1/mgmt/fw-boot-def/bootunit-combined'
adminState='trigger' image='backup' resetOnActivate='yes' />
</inConfig>
</configConfMo>
Response:
<configConfMocookie="1369391866/63bd7c70-dd74-1d74-8002-233362a70344" response="yes"
dn="sys/rack-unit-1/mgmt/fw-boot-def/bootunit-combined">
<outConfig>
<firmwareBootUnit dn="sys/rack-unit-1/mgmt/fw-boot-def/bootunit-combined" adminState="triggered"
image="running" resetOnActivate="no" type="combined" version="1.5(1f)"
status="modified">
</firmwareBootUnit>
</outConfig>
</configConfMo>
Using the inHierarchical Option to Retrieve Configured Boot Order Table
Request:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="true" classId="lsbootDef">
Response:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
response="yes"
classId="lsbootDef">
<outConfig>
<lsbootDef dn="sys/rack-unit-1/boot-policy" name="boot-policy"
purpose="operational" rebootOnUpdate="no" >
<lsbootVirtualMedia access="read-only" order="3"
type="virtual-media" rn="vm-read-only" />
<lsbootVirtualMedia access="read-write" order="5"
type="virtual-media" rn="vm-read-write"/>
<lsbootLan rn="lan-read-only" access="read-only" order="2"
prot="pxe" type="lan" />
<lsbootStorage rn="storage-read-write" access="read-write" order="1"
type="storage" >
<lsbootLocalStorage rn="local-storage" />
</lsbootStorage>
<lsbootEfi rn="efi-read-only" access="read-only" order="4"
type="efi" />
</lsbootDef>
</outConfig>
</configResolveClass>
Retrieving Power Supply Unit Details on Server
Request:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="false" classId="equipmentPsu">
Response:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
response="yes"
classId="equipmentPsu">
<outConfig>
<equipmentPsu id="1" model="UCSC-PSU-450W" operability="operable" power="on"
presence="equipped" serial="DCB1621010X" thermal="ok"
vendor="Cisco Systems Inc" voltage="unknown" dn="sys/rack-unit-1/psu-1" >
<equipmentPsu id="2" model="" operability="unknown" power="off"
presence="missing" serial="" thermal="unknown" vendor=""
voltage="unknown" dn="sys/rack-unit-1/psu-2" >
</outConfig>
</configResolveClass>
Retrieving Details of Fan Object Identified by DN
Request:
<configResolveDn cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="false" dn="sys/rack-unit-1/fan-module-1-2/fan-2"/>
Response:
<configResolveDn cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
response="yes"
dn="sys/rack-unit-1/fan-module-1-2/fan-2"/>
<outConfig>
<equipmentFan id="2" model="" module="2" operability="operable" power="on"
presence="equipped" serial="" thermal="not-supported" tray="1" vendor=""
voltage="not-supported" dn="sys/rack-unit-1/fan-module-1-2/fan-2"/>
</outConfig>
</configResolveDn>
Retrieving SNMP Configuration Details
Request:
<configResolveClass cookie="1313086522/c7c08988-aa3e-1a3e-8005-5e61c2e14388"
inHierarchical="false" classId="commSnmp"/>
Response:
<configResolveClass cookie="1362107065/43d02d50-d6d4-16d4-8009-c979e5e53d50"
response="yes"
classId="commSnmp">
<outConfigs>
<commSnmp dn="sys/svc-ext/snmp-svc" descr="SNMP Service" name="snmp" adminState="enabled"
port="161" proto="udp" community="" trapCommunity="public" com2Sec="disabled"
sysContact="who@where" sysLocation="unknown"/>
</outConfigs>
</configResolveClass>
Retrieving Status of Local Hard Disk on Server
Request:
<configResolveDn cookie="1313146313/b38e04a0-aa4c-1a4c-8008-cdac38e14388"
inHierarchical="false" dn="sys/rack-unit-1/board/disk-4"/>
Response:
<configResolveDn cookie="1313146313/b38e04a0-aa4c-1a4c-8008-cdac38e14388"
response="yes"
dn="sys/rack-unit-1/board/disk-4">
<outConfig>
<storageLocalDiskSlotEp id="4" operability="operable" presence="equipped"
dn="sys/rack-unit-1/board/disk-4"/>
</outConfig>
</configResolveDn>
Power Cycling the Server
Request:
<configConfMo cookie="1313084260/40ea8058-aa3e-1a3e-8004-5e61c2e14388"
inHierarchical="false" dn="sys/rack-unit-1" >
<inConfig>
<computeRackUnit adminPower="cycle-immediate" dn="sys/rack-unit-1">
</computeRackUnit>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313084260/40ea8058-aa3e-1a3e-8004-5e61c2e14388"
response="yes" dn="sys/rack-unit-1" >
<outConfig>
<computeRackUnit dn="sys/rack-unit-1" adminPower="policy" availableMemory="49152"
model="R250-2480805W" memorySpeed="1067" name="UCS C250 M2" numOfAdaptors="1"
numOfCores="8" numOfCoresEnabled="8" numOfCpus="2" numOfEthHostIfs="0"
numOfFcHostIfs="0" numOfThreads="16" operPower="off"
originalUuid="100DC440-0EBC-11DF-3B97-8843E1C2615E" presence="equipped" serverId="1"
serial="PGS140601CS" totalMemory="49152" usrLbl="Cisco C210 Server"
uuid="100DC440-0EBC-11DF-3B97-8843E1C2615E" vendor="Cisco Systems Inc"
status="modified"/>
</outConfig>
</configConfMo>
Configuring EFI as the Second Boot Device in Boot Order Table
Request:
<configConfMo cookie="1313090863/ca79ef88-aa3f-1a3f-8006-5e61c2e14388"
inHierarchical="false" dn="sys/rack-unit-1/boot-policy/efi-read-only">
<inConfig>
<lsbootEfi order="2" status="modified"
dn="sys/rack-unit-1/boot-policy/efi-read-only"
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313090863/ca79ef88-aa3f-1a3f-8006-5e61c2e14388"
response="yes" dn="sys/rack-unit-1/boot-policy/efi-read-only" >
<outConfig>
<lsbootEfi dn="sys/rack-unit-1/boot-policy/efi-read-only" access="read-only"
order="2" type="efi" status="modified"/>
</outConfig>
</configConfMo>
Removing Floppy Disk Drive as a Boot Device From the Boot Order List
Request:
<configConfMo cookie="1313092854/412183f8-aa40-1a40-8007-5e61c2e14388"
inHierarchical="true" dn="sys/rack-unit-1/boot-policy/vm-read-write" >
<inConfig>
<lsbootVirtualMedia order="5" access="read-write" status="deleted"
dn="sys/rack-unit-1/boot-policy/vm-read-write"/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313092854/412183f8-aa40-1a40-8007-5e61c2e14388" response="yes"
dn="sys/rack-unit-1/boot-policy/vm-read-write" >
<outConfig>
</outConfig>
</configConfMo>
Configuring Boot Order to HDD, CDROM, FDD, PXE, and EFI Without Rebooting the Host
Request:
<configConfMo cookie="1360205300/79c672f0-d519-1519-8004-30339ee53d50"
inHierarchical="true" dn="sys/rack-unit-1/boot-policy">
<inConfig>
<lsbootDef dn="sys/rack-unit-1/boot-policy" rebootOnUpdate="no">
<lsbootVirtualMedia access="read-only" order="2" type="virtual-media"
rn="vm-read-only"/>
<lsbootVirtualMedia access="read-write" order="3" type="virtual-media"
rn="vm-read-write"/>
<lsbootLan rn="lan-read-only" access="read-only" order="4" prot="pxe" type="lan"/>
<lsbootStorage rn="storage-read-write" access="read-write" order="1" type="storage"
<lsbootLocalStorage rn="local-storage"/> </lsbootStorage>
<lsbootEfi rn="efi-read-only" access="read-only" order="5" type="efi"/>
</lsbootDef>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1360205300/79c672f0-d519-1519-8004-30339ee53d50" response="yes"
dn="sys/rack-unit-1/boot-policy">
<outConfig>
<lsbootDef dn="sys/rack-unit-1/boot-policy" name="boot-policy" purpose="operational"
rebootOnUpdate="no" status="modified">
<lsbootVirtualMedia access="read-only" order="2" type="virtual-media" rn="vm-read-only"
status="modified"/>
<lsbootVirtualMedia access="read-write" order="3" type="virtual-media" rn="vm-read-write"
status="modified"/>
<lsbootLan rn="lan-read-only" access="read-only" order="4" prot="pxe" type="lan"
status="modified"/>
<lsbootStorage rn="storage-read-write" access="read-write" order="1" type="storage"
status="modified">
<lsbootLocalStorage rn="local-storage" status="modified"/>
</lsbootStorage>
<lsbootEfi rn="efi-read-only" access="read-only" order="5" type="efi"
status="modified"/>
</lsbootDef>
</outConfig>
</configConfMo>
Using inHierarchical Option to Change and Retrieve SNMP Configuration of Trap Receivers
Request:
<configConfMo cookie="1362115258/2c1b1380-d6d6-16d6-800b-c979e5e53d50"
inHierarchical="true" dn="sys/svc-ext/snmp-svc">
<inConfig>
<commSnmp dn="sys/svc-ext/snmp-svc" adminState="enabled" community="Top$ecrt"
trapCommunity="Dar$Good" com2Sec="full" sysContact="snmpadmin@cisco"
port='600' sysLocation="San Jose"/>
</inConfig>
Response:
<configConfMo cookie="1398652603/2f9bf4c8-f811-1811-8005-79bdaa4c93a4" response="yes"
dn="sys/svc-ext/snmp-svc">
<outConfig>
<commSnmp dn="sys/svc-ext/snmp-svc" descr="SNMP Service" name="snmp"
adminState="enabled" port="600" proto="udp" community="public"
trapCommunity="public" com2Sec="full" sysContact="testContact"
sysLocation="testLocation" status="modified" >
<commSnmpTrap id="1" adminState="disabled" version="v3"
notificationType="traps" port="162" hostname="0.0.0.0" user="unknown"
rn="snmp-trap-1" status="modified">
</commSnmpTrap>
<commSnmpTrap id="2" adminState="disabled" version="v3">
notificationType="traps" port="162" hostname="0.0.0.0" user="unknown">
rn="snmp-trap-2" status="modified">
</commSnmpTrap>
.
.
.
<commSnmpUser id="15" name=""
securityLevel="" auth="" authPwd="" privacy="" privacyPwd=""
rn="snmpv3-user-15" status="modified"
</commSnmpUser>
</commSnmp>
</outConfig>
Retrieving Select Memory RAS BIOS Token
Request:
<configResolveClass cookie="1313092854/412183f8-aa40-1a40-8007-5e61c2e14388"
inHierarchical="false" classId="biosVfSelectMemoryRASConfiguration"/>
Response:
<configResolveClass cookie="1313092854/412183f8-aa40-1a40-8007-5e61c2e14388" response="yes"
classId="biosVfSelectMemoryRASConfiguration">
<outConfig>
<biosVfSelectMemoryRASConfiguration
dn="sys/rack-unit-1/bios/bios-settings/SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="maximum-performance" >
</biosVfSelectMemoryRASConfiguration>
</outConfig>
</configResolveClass>
Configuring Select Memory RAS BIOS Token for Mirroring Mode
Request:
<configConfMo cookie="1313092854/412183f8-aa40-1a40-8007-5e61c2e14388"
inHierarchical="false" dn="sys/rack-unit-1/bios/bios-settings/SelectMemory-RAS-configuration">
<inConfig>
<biosVfSelectMemoryRASConfiguration
dn="sys/rack-unit-1/bios/bios-settings/SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="mirroring">
</biosVfSelectMemoryRASConfiguration>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313092854/412183f8-aa40-1a40-8007-5e61c2e14388" response="yes"
dn="sys/rack-unit-1/bios/bios-settings/SelectMemory-RAS-configuration">
<outConfig>
<biosVfSelectMemoryRASConfiguration
dn="sys/rack-unit-1/bios/bios-settings/SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="mirroring" status="modified"/>
</outConfig>
</configConfMo>
Note |
After configuring the BIOS tokens, reboot the host for the configured tokens to reflect on the host side. |
Retrieving C240 Server BIOS Token Values
Request:
<configResolveClass cookie="1360207841/1133b530-d51a-151a-8005-30339ee53d50"
inHierarchical="true" classId="biosSettings"/>
Response:
<configResolveClass cookie="1362115258/2c1b1380-d6d6-16d6-800b-c979e5e53d50" response="yes"
classId="biosSettings">
<outConfigs>
<biosSettings dn="sys/rack-unit-1/bios/bios-settings">
<biosVfIntelVTForDirectedIO rn="Intel-VT-for-directed-IO"
vpIntelVTDATSSupport="enabled" vpIntelVTDCoherencySupport="disabled"
vpIntelVTForDirectedIO="enabled"/>
<biosVfSelectMemoryRASConfiguration rn="SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="maximum-performance"/>
<biosVfProcessorC6Report rn="Processor-C6-Report" vpProcessorC6Report="enabled"/>
<biosVfIntelHyperThreadingTech rn="Intel-HyperThreading-Tech"
vpIntelHyperThreadingTech="enabled"/>
<biosVfEnhancedIntelSpeedStepTech rn="Enhanced-Intel-SpeedStep-Tech"
vpEnhancedIntelSpeedStepTech="enabled"/>
<biosVfIntelVirtualizationTechnolog rn="Intel-Virtualization-Technology"
vpIntelVirtualizationTechnology="enabled"/>
<biosVfMemoryMappedIOAbove4GB rn="Memory-mapped-IO-above-4GB"
vpMemoryMappedIOAbove4GB="disabled"/>
<biosVfCPUPerformance rn="CPU-Performance" vpCPUPerformance="enterprise"/>
<biosVfLvDIMMSupport rn="LvDIMM-Support" vpLvDDRMode="performance-mode"/>
<biosVfNUMAOptimized rn="NUMA-optimized" vpNUMAOptimized="enabled"/>
<biosVfConsoleRedirection rn="Console-redirection" vpBaudRate="115200"
vpConsoleRedirection="disabled" vpFlowControl="none" vpTerminalType="vt100"
vpPuttyKeyPad="ESCN" vpRedirectionAfterPOST="Always Enable"/>
<biosVfCoreMultiProcessing rn="Core-MultiProcessing" vpCoreMultiProcessing="all"/>
<biosVfIntelTurboBoostTech rn="Intel-Turbo-Boost-Tech"
vpIntelTurboBoostTech="enabled"/>
<biosVfDirectCacheAccess rn="Direct-Cache-Access" vpDirectCacheAccess="enabled"/>
<biosVfExecuteDisableBit rn="Execute-Disable-Bit" vpExecuteDisableBit="enabled"/>
<biosVfOSBootWatchdogTimer rn="OS-Boot-Watchdog-Timer-Param"
vpOSBootWatchdogTimer="disabled"/>
<biosVfOSBootWatchdogTimerPolicy rn="OS-Boot-Watchdog-Timer-Policy"
vpOSBootWatchdogTimerPolicy="power-off"/>
<biosVfOSBootWatchdogTimerTimeOut rn="OS-Boot-Watchdog-Timer-Time-Out"
vpOSBootWatchdogTimerPolicy="10-minutes"/>
<biosVfHardwarePrefetch rn="Hardware-Prefetch" vpHardwarePrefetch="enabled"/>
<biosVfAdjacentCacheLinePrefetch rn="Adjacent-Cache-Line-Prefetch"
vpAdjacentCacheLinePrefetch="enabled"/>
<biosVfFRB2Enable rn="FRB2-Enable" vpFRB2Enable="enabled"/>
<biosVfProcessorC1E rn="Processor-C1E" vpProcessorC1E="enabled"/>
<biosVfPatrolScrub rn="Patrol-Scrub-Param" vpPatrolScrub="enabled"/>
<biosVfTPMSupport rn="TPM-Support" vpTPMSupport="disabled"/>
<biosVfDCUPrefetch rn="DCU-Prefetch" vpStreamerPrefetch="enabled"
vpIPPrefetch="enabled"/>
<biosVfCPUPowerManagement rn="CPU-PowerManagement"
vpCPUPowerManagement="energy-efficient"/>
<biosVfCPUFrequencyFloor rn="CPU-FreqFloor" vpCPUFrequencyFloor="disabled"/>
<biosVfCPUEnergyPerformance rn="CPU-EngPerfBias"
vpCPUEnergyPerformance="balanced-performance"/>
<biosVfMemoryInterleave rn="Memory-Interleave" vpChannelInterLeave="auto"
vpRankInterLeave="auto"/>
<biosVfDemandScrub rn="Demand-Scrub-Param" vpDemandScrub="enabled"/>
<biosVfAltitude rn="Altitude-Param" vpAltitude="300-m"/>
<biosVfDRAMClockThrottling rn="DRAM-Clock-Throttling"
vpDRAMClockThrottling="Balanced"/>
<biosVfASPMSupport rn="ASPM-Support" vpASPMSupport="Disabled"/>
<biosVfVgaPriority rn="VgaPriority" vpVgaPriority="Onboard"/>
<biosVfUSBPortsConfig rn="USB-Ports-Config" vpAllUsbDevices="enabled"
vpUsbPortRear="enabled" vpUsbPortFront="enabled" vpUsbPortInternal="enabled"
vpUsbPortKVM="enabled" vpUsbPortVMedia="enabled" vpUsbPortSDCard="enabled"/>
<biosVfQPIConfig rn="QPI-Config" vpQPILinkFrequency="auto"/>
<biosVfLegacyUSBSupport rn="LegacyUSB-Support" vpLegacyUSBSupport="enabled"/>
<biosVfUCSMBootOrderRuleControl rn="Boot-Order-Rules"
vpUCSMBootOrderRule="Loose"/>
<biosVfPCIOptionROMs rn="PCI-OptionROMs" vpPCIOptionROMs="Enabled"/>
<biosVfLOMPortOptionROM rn="LOMPort-OptionROM" vpLOMPortsAllState="Enabled"
vpLOMPort0State="Enabled" vpLOMPort1State="Enabled" vpLOMPort2State="Enabled"
vpLOMPort3State="Enabled"/>
<biosVfPCISlotOptionROMEnable rn="PCI-Slot-OptionROM-Enable"
vpSlot1State="Enabled" vpSlot2State="Enabled" vpSlot3State="Enabled"
vpSlot4State="Enabled" vpSlot5State="Enabled" vpSlot6State="Enabled"
vpSlot7State="Enabled" vpSlot1LinkSpeed="GEN3" vpSlot2LinkSpeed="GEN3"
vpSlot3LinkSpeed="GEN3" vpSlot4LinkSpeed="GEN3" vpSlot5LinkSpeed="GEN3"
vpSlot6LinkSpeed="GEN3" vpSlot7LinkSpeed="GEN3"/>
<biosVfPStateCoordType rn="p-state-coord" vpPStateCoordType="HW ALL"/>
<biosVfDramRefreshRate rn="dram-refresh-rate" vpDramRefreshRate="2x"/>
<biosVfOutOfBandMgmtPort rn="OoB-MgmtPort"
vpOutOfBandMgmtPort="Disabled" >
</biosVfOutOfBandMgmtPort>
</biosSettings>
</outConfigs>
Retrieving Default Values of BIOS Tokens
Request:
<configResolveClass cookie='1307953743/b63ff130-a593-1593-8004-2e4ac2e14388'
classId='biosPlatformDefaults' inHierarchical='true'>
Response:
<configResolveClass cookie="1370842491/23c0a810-dec6-1ec6-8002-1ec9e1a85750"
response="yes" classId="biosPlatformDefaults">
<outConfigs>
<biosPlatformDefaults dn="sys/rack-unit-1/bios/bios-defaults" >
<biosVfIntelVTForDirectedIO rn="Intel-VT-for-directed-IO"
vpIntelVTDATSSupport="enabled"
vpIntelVTDCoherencySupport="disabled"
vpIntelVTForDirectedIO="enabled" >
</biosVfIntelVTForDirectedIO>
<biosVfSelectMemoryRASConfiguration rn="SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="maximum-performance" >
</biosVfSelectMemoryRASConfiguration>
<biosVfProcessorC6Report rn="Processor-C6-Report"
vpProcessorC6Report="enabled" >
</biosVfProcessorC6Report><biosVfIntelHyperThreadingTech rn="Intel-HyperThreading-Tech"
vpIntelHyperThreadingTech="enabled" >
</biosVfIntelHyperThreadingTech>
<biosVfEnhancedIntelSpeedStepTech rn="Enhanced-Intel-SpeedStep-Tech"
vpEnhancedIntelSpeedStepTech="enabled" >
</biosVfEnhancedIntelSpeedStepTech>
<biosVfIntelVirtualizationTechnology rn="Intel-Virtualization-Technology"
vpIntelVirtualizationTechnology="enabled" >
</biosVfIntelVirtualizationTechnology>
.
.
.
</biosVfLOMPortOptionROM><biosVfPCISlotOptionROMEnable rn="PCI-Slot-OptionROM-Enable"
vpSlot1State="Enabled"
vpSlot2State="Enabled"
vpSlotMezzState="Enabled"
vpSlot2LinkSpeed="GEN3" >
</biosVfPCISlotOptionROMEnable><biosVfPStateCoordType rn="p-state-coord"
vpPStateCoordType="HW ALL" >
</biosVfPStateCoordType>
<biosVfDramRefreshRate rn="dram-refresh-rate"
vpDramRefreshRate="2x" >
</biosVfDramRefreshRate>
</biosPlatformDefaults>
</outConfigs>
</configResolveClass>
Using Platform-Default to Configure BIOS Parameters to Default Values
Request:
<configConfMo cookie="0000020175/b2909140-0004-1004-8002-cdac38e14388"
inHierarchical="true" dn="sys/rack-unit-1/bios/bios-settings">
<inConfig>
<biosSettings>
<biosVfIntelVTForDirectedIO dn="sys/rack-unit-1/bios/bios-settings/Intel-VT-for-directed-IO"
vpIntelVTDATSSupport="platform-default" vpIntelVTDCoherencySupport="platform-default"
vpIntelVTForDirectedIO="platform-default"/>
<biosVfSelectMemoryRASConfiguration dn="sys/rack-unit-1/bios/bios-settings/SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="platform-default"/>
…..
…..
…..
<biosVfProcessorC6Report dn="sys/rack-unit-1/bios/bios-settings/Processor-C6-Report"
vpSlot2State="platform-default" vpSlotMezzState="platform-default" vpSlot1LinkSpeed="platform-default"
vpSlot2LinkSpeed="platform-default"/>
<biosVfPStateCoordType dn="sys/rack-unit-1/bios/bios-settings/p-state-coord"
vpPStateCoordType="platform-default"/>
</biosSettings>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1347919470/f5335af8-c9ec-19ec-8007-1ec9e1a85750" response="yes"
dn="sys/rack-unit-1/mgmt/fw-updatable" >
<outConfig>
<biosSettings dn="sys/rack-unit-1/bios/bios-settings" status="modified" >
<biosVfIntelVTForDirectedIO rn="Intel-VT-for-directed-IO"
vpIntelVTDATSSupport="enabled" vpIntelVTDCoherencySupport="disabled"
vpIntelVTForDirectedIO="enabled" status="modified" >
</biosVfIntelVTForDirectedIO>
<biosVfSelectMemoryRASConfiguration rn="SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="maximum-performance" status="modified" >
.
.
.
vpSlot1State="enabled" vpSlot2State="enabled" vpSlotMezzState="enabled"
vpSlot1LinkSpeed="GEN3" vpSlot2LinkSpeed="GEN3" status="modified"
</biosVfPCISlotOptionROMEnable>
<biosVfPStateCoordType rn="p-state-coord" vpPStateCoordType="HW_ALL"
status="modified" >
</biosVfPStateCoordType>
</biosSettings>
</outConfig>
</configConfMo>
Note |
The request and response in the preceding example is not the complete output, only a part of it has been included. |
This will set the BIOS parameters such as the Processor, Memory, QPI, PCI, Serial, LOM and PCIe slots configuration settings to platform-default values. Similarly, you can configure the BIOS parameters by changing the platform-default input parameter in the example to what you want to configure.
Setting the Out-Of-Band-Mgmt-Port BIOS Token Value
Request:
<configConfMo cookie="1462352296/f3b4e630-3200-1200-8002-f0fa5ff6083c"
inHierarchical="false" dn="sys/rack-unit-1/bios/bios-settings/OoB-MgmtPort">
<inConfig>
<biosVfOutOfBandMgmtPort dn="sys/rack-unit-1/bios/bios-settings/OoB-MgmtPort" vpOutOfBandMgmtPort="Disabled">
</biosVfOutOfBandMgmtPort>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/bios/bios-settings/OoB-MgmtPort"
cookie="1462352296/f3b4e630-3200-1200-8002-f0fa5ff6083c" response="yes">
<outConfig>
<biosVfOutOfBandMgmtPort dn="sys/rack-unit-1/bios/bios-settings/OoB-MgmtPort"
vpOutOfBandMgmtPort="Disabled" status="modified"/>
</outConfig>
</configConfMo>
Using TFTP to Export Cisco IMC Configuration Data
Request:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false"> dn="sys/export-config"
<inConfig>
<mgmtBackup dn="sys/export-config" adminState="enabled" hostname="198.xx.210.xx"
remoteFile="/tftpserver/c250_config_export.cfg"/>
user='<username>' pwd='<password>' passphrase='passphrase'>
</mgmtBackup>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
response="yes" dn="sys/export-config">
<outConfig>
<mgmtBackup dn="sys/export-config" adminState="disabled" fsmStageDescr="Completed successfully"
fsmRmtInvErrCode="" fsmRmtInvErrDescr="NONE" fsmDescr="export-config" proto="tftp" hostname=""
remoteFile="" user="" pwd="" passphrase="" status="modified"/>
</outConfig>
</configConfMo>
The preceding request launches the export operation, which executes as a background task.
The exported configuration file resembles the following example:
[root]# cat /tftpserver/c250_config_export.cfg
<root><CIMC>
<version>1.4(0.22)</version>
<network>
<hostname>ucs-c250-M2</hostname>
<mode>dedicated</mode>
<redundancy>active-standby</redundancy>
<dns-use-dhcp>no</dns-use-dhcp>
<preferred-dns-server>0.0.0.0</preferred-dns-server>
<alternate-dns-server>0.0.0.0</alternate-dns-server>
<vlan-enabled>no</vlan-enabled>
.
.
.
TFTP used in the preceding example is the default protocol. You can also export the Cisco IMC configuration using the other available protocols such as the ftp, sftp, scp and http. Exporting using the ftp, sftp and scp requires user credentials, as shown in the following example:
Request:
configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" dn="sys/export-config"
<inConfig>
<mgmtBackup dn="sys/export-config" adminState="enabled"
hostname="bxxxa-xxx-fileserver.cisco.com" proto="ftp"
user="username" pwd="password" passphrase='passphrase'
remoteFile="/home/xxxxx/ppapi.xml">
/inConfig>
Response:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388" response="yes">
dn="sys/export-config"
<outConfig>
<mgmtBackup dn="sys/export-config" adminState="disabled"
fsmStageDescr="Completed successfully" fsmRmtInvErrCode=""
fsmRmtInvErrDescr="NONE"
fsmDescr="export-config" proto="ftp" hostname="" remoteFile=""
User="" pwd="" passphrase="" status="modified"/>
</outConfig>
</configConfMo>
Using TFTP to Import Cisco IMC Configuration Data
Request:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" dn="sys/import-config">
<inConfig>
<mgmtImporter dn="sys/import-config" adminState="enabled" hostname="10.10.10.10"
remoteFile="/tftpserver/c250_config_export.cfg" user="user" pwd="password" passphrase="passphrase"/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
response="yes" dn="sys/import-config">
<outConfig>
<mgmtImporter dn="sys/import-config" adminState="disabled" fsmStageDescr="Error"
fsmRmtInvErrCode="" fsmRmtInvErrDescr="NONE" fsmDescr="import-config" proto="tftp" hostname=""
remoteFile="" user="" pwd="" passphrase="" status="modified"/>
</outConfig>
</configConfMo>
The preceding request launches the import operation, which executes as a background task. You can periodically query for the completion status by sending the following requests:
Status request:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" classId="mgmtImporter"/>
Status response before completion:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388" response="yes"
classId="mgmtImporter">
<outConfig>
<mgmtImporter dn="sys/import-config" adminState="enabled"
fsmStageDescr="Applying configuration" fsmRmtInvErrCode=""
fsmRmtInvErrDescr="NONE" fsmDescr="import-config" proto="none" hostname=""
remoteFile="" user="" pwd=""/>
</outConfig>
</configResolveClass>
Repeated status request:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" classId="mgmtImporter"/>
Status response after completion:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388" response="yes"
classId="mgmtImporter">
<outConfig>
<mgmtImporter dn="sys/import-config" adminState="disabled"
fsmStageDescr="Completed successfully" fsmRmtInvErrCode=""
fsmRmtInvErrDescr="NONE" fsmDescr="import-config" proto="none" hostname=""
remoteFile="" user="" pwd=""/>
</outConfig>
</configResolveClass>
Using TFTP to Export Cisco IMC Technical Support Data
Request:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" dn="sys/rack-unit-1/tech-support">
<inConfig>
<sysdebugTechSupportExport dn="sys/rack-unit-1/tech-support" adminState="enabled"
remoteFile="/tftpserver/c250_techsupport_archive.tgz" proto="tftp"
hostname="198.xx.xxx.14"/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388" response="yes"
dn="sys/rack-unit-1/tech-support" >
<outConfig>
<sysdebugTechSupportExport dn="sys/rack-unit-1/tech-support" adminState="disabled"
hostname="198.xx.xxx.14" proto="tftp"
remoteFile="/tftpserver/c250_techsupport_archive.tgz" fsmStageDescr="none"
fsmProgr="0" fsmStatus="nop" status="modified"/>
</outConfig>
</configConfMo>
The preceding request launches the technical support generation, after technical support data is generated, it is uploaded to the remote location. You can periodically query for the completion status by sending the following requests:
Status request:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" classId="sysdebugTechSupportExport"/>
Status response before completion:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388" response="yes"
classId="sysdebugTechSupportExport">
<outConfig>
<sysdebugTechSupportExport dn="sys/rack-unit-1/tech-support" adminState="enabled"
hostname="10.10.10.10" proto="tftp"
remoteFile="/tftpserver/c250_techsupport_archive.tgz"
fsmStageDescr="collecting" fsmProgr="0" fsmStatus="exporting"/>
</outConfig>
</configResolveClass>
Repeated status request:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388"
inHierarchical="false" classId="sysdebugTechSupportExport"/>
Status response after completion:
<configResolveClass cookie="1313118253/2b07f100-aa46-1a46-8008-5e61c2e14388" response="yes"
classId="sysdebugTechSupportExport">
<outConfig>
<sysdebugTechSupportExport dn="sys/rack-unit-1/tech-support" adminState="disabled"
hostname="10.10.10.10" proto="tftp"
remoteFile="/tftpserver/c250_techsupport_archive.tgz"
fsmStageDescr="completed" fsmProgr="100" fsmStatus="success"/>
</outConfig>
</configResolveClass>
The exported technical support file resembles the following example:
[root]# tar tvfz /tftpserver/c250_techsupport_archive.tgz | more
drwxr-xr-x root/root 0 2011-08-11 13:01:10 obfl/
-rw-r--r-- root/root 76910 2011-08-11 13:00:56 obfl/obfl-log.1
-rw-r--r-- root/root 76835 1970-01-01 09:38:26 obfl/obfl-log.2
-rw-r--r-- root/root 76881 2011-08-08 21:20:55 obfl/obfl-log.3
-rw-r--r-- root/root 76916 1969-12-31 16:07:28 obfl/obfl-log.4
-rw-r--r-- root/root 76846 2011-08-03 21:38:49 obfl/obfl-log.5
-rw-r--r-- root/root 14598 2011-08-11 20:49:57 obfl/obfl-log
.
.
.
Retrieving CPU Product ID Details
Request:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
inHierarchical="false" classId="pidCatalogCpu"/>
Response:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
response="yes" classId="pidCatalogCpu"> <outConfigs> <pidCatalogCpu id="1" socketdesignation="CPU1"
description="Intel(R) Xeon(R) E5-2650 2.00GHz 8-core 95W 20MB Cache DDR3 1600MHz" pid="UCS-CPU-E5-2650"
model="Intel(R) Xeon(R) CPU E5-2650 0 @ 2.00GHz" signature="Type 0, Family 6, Model 45, Stepping 7" currentspeed="2000"
operState="Enabled" dn="sys/rack-unit-1/board/pid/pid-cpu-1" ></pidCatalogCpu><pidCatalogCpu id="2" socketdesignation="CPU2"
description="Intel(R) Xeon(R) E5-2650 2.00GHz 8-core 95W 20MB Cache DDR3 1600MHz" pid="UCS-CPU-E5-2650" model="Intel(R) Xeon(R)
CPU E5-2650 0 @ 2.00GHz" signature="Type 0, Family 6, Model 45, Stepping 7" currentspeed="2000" operState="Enabled"
dn="sys/rack-unit-1/board/pid/pid-cpu-2" ></pidCatalogCpu></outConfigs> </configResolveClass>
Retrieving IMM/ Memory Unit Product ID Details
Request:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
inHierarchical="false" classId="pidCatalogDimm"
Response:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
response="yes" classId="pidCatalogDimm"> <outConfigs> <pidCatalogDimm name="DIMM_A1"
description="8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v" pid="UCS-MR-1X082RY-A" mfgid="0xCE00"
manufacturer="Samsung Electronics, Inc." serialnumber="14765DC9 " model="Mx93B1K70DH0-YK0" capacity="8192 MB"
speed="1600" datawidth="64 bits" operability="Operable" dn="sys/rack-unit-1/board/pid/pid-dimm-DIMM_A1" >
</pidCatalogDimm><pidCatalogDimm name="DIMM_B1" description="8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v"
pid="UCS-MR-1X082RY-A" mfgid="0xCE00" manufacturer="Samsung Electronics, Inc." serialnumber="1494DE1A "
model="Mx93B1K70DH0-YK0" capacity="8192 MB" speed="1600" datawidth="64 bits" operability="Operable"
dn="sys/rack-unit-1/board/pid/pid-dimm-DIMM_B1" ></pidCatalogDimm><pidCatalogDimm name="DIMM_E1"
description="8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v" pid="UCS-MR-1X082RY-A" mfgid="0xCE00"
manufacturer="Samsung Electronics, Inc." serialnumber="1474F06F " model="Mx93B1K70DH0-YK0" capacity="8192 MB"
speed="1600" datawidth="64 bits" operability="Operable" dn="sys/rack-unit-1/board/pid/pid-dimm-DIMM_E1" >
</pidCatalogDimm><pidCatalogDimm name="DIMM_F1" description="8GB DDR3-1600-MHz RDIMM/PC3-12800/dual rank/1.35v"
pid="UCS-MR-1X082RY-A" mfgid="0xCE00" manufacturer="Samsung Electronics, Inc." serialnumber="1494D625 "
model="Mx93B1K70DH0-YK0" capacity="8192 MB" speed="1600" datawidth="64 bits" operability="Operable"
dn="sys/rack-unit-1/board/pid/pid-dimm-DIMM_F1" ></pidCatalogDimm></outConfigs> </configResolveClass>
Retrieving HDD Product ID Details
Request:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
inHierarchical="false" classId="pidCatalogHdd"/>
Response:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
response="yes" classId="pidCatalogHdd">
<outConfigs>
<pidCatalogHdd disk="1" controller="SLOT-4" description="300GB 6Gb SAS 10K RPM 2.5"
pid="A03-D300GA2" vendor="SEAGATE" model="ST300MM0006" serialnumber="Z0K01B3K0000C4171HJU"
dn="sys/rack-unit-1/board/pid/pid-hdd-1" >
</pidCatalogHdd>
<pidCatalogHdd disk="2" controller="SLOT-4" description="300GB 6Gb SAS 10K RPM 2.5"
pid="A03-D300GA2" vendor="SEAGATE" model="ST300MM0006" serialnumber="Z0K01GP10000C419ARHL"
dn="sys/rack-unit-1/board/pid/pid-hdd-2" >
</pidCatalogHdd>
</outConfigs>
</configResolveClass>
Retrieving PCI Adapter Product ID Details
Request:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
inHierarchical="false" classId="pidCatalogPCIAdapter"/>
Response:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c" response="yes"
classId="pidCatalogPCIAdapter"> <outConfigs> <pidCatalogPCIAdapter slot="L"
description="Onboard LOM" pid="N/A" vendor="0x8086" device="0x1521" subvendor="0x1137"
subdevice="0x008b" dn="sys/rack-unit-1/board/pid/pid-pciadapter-L" ></pidCatalogPCIAdapter>
<pidCatalogPCIAdapter slot="2" description="Cisco UCS Dual Port 10Gb Ethernet and 4G Fibre Channel CNA SFP+"
pid="UCSC-PCIE-CSC-02" vendor="0x1137" device="0x0042" subvendor="0x1137" subdevice="0x0085"
dn="sys/rack-unit-1/board/pid/pid-pciadapter-2" ></pidCatalogPCIAdapter><pidCatalogPCIAdapter slot="4"
description="LSI 6G MegaRAID SAS 9271-8i card with Supercap (RAID 0,1,5,6; RAID spans 10,50,60) - External mini-SAS connectors"
pid="UCS-RAID9271-8i" vendor="0x1000" device="0x005b" subvendor="0x1000" subdevice="0x9271"
dn="sys/rack-unit-1/board/pid/pid-pciadapter-4" ></pidCatalogPCIAdapter></outConfigs> </configResolveClass>
Retrieving Firmware Update Details
Request:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
inHierarchical="false" classId="firmwareUpdatable"/>
Response:
<configResolveClass cookie="1462354358/4b33a4f4-3201-1201-8004-f0fa5ff6083c"
response="yes" classId="firmwareUpdatable">
<outConfigs>
<firmwareUpdatable dn="sys/rack-unit-1/bios/fw-updatable" description="BIOS firmware version"
adminState="triggered" deployment="primary" operState="ready" version="CxxxMx.3.0.0.3
(Build Date: 03/23/2016)" protocol="none" remoteServer="" remotePath="" user=""
pwd="" progress="None, OK" type="blade-bios" >
</firmwareUpdatable>
<firmwareUpdatable dn="sys/rack-unit-1/mgmt/fw-updatable"
description="Cisco IMC backup firmware version"
adminState="triggered" deployment="backup" operState="ready"
version="66.77(67.1462359966)" protocol="none"
remoteServer="" remotePath="" user="" pwd="" progress="Success"
type="blade-controller" secureBoot="enabled" >
</firmwareUpdatable>
<firmwareUpdatable dn="sys/rack-unit-1/adaptor-2/mgmt/fw-updatable"
description="Cisco VIC adapter backup firmware version" adminState="triggered" deployment="backup"
version="2.1(3a)" protocol="none" remoteServer="" remotePath="" user="" pwd=""
progress="Stage: No operation (0%), Status: Idle, Error: No error" type="adaptor" >
</firmwareUpdatable>
</outConfigs>
</configResolveClass>
Updating Cisco IMC Firmware
Request:
<configConfMo cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/mgmt/fw-updatable">
<inConfig>
<firmwareUpdatable adminState="trigger" dn="sys/rack-unit-1/mgmt/fw-updatable"
protocol="tftp" remoteServer="10.10.10.10" remotePath="update_pkg-rack-colusa1.bin"
type="blade-controller"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/mgmt/fw-updatable"
cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c" response="yes">
<outConfig>
<firmwareUpdatable dn="sys/rack-unit-1/mgmt/fw-updatable"
description="Cisco IMC backup firmware version" adminState="triggered"
deployment="backup" operState="updating" version="3.0(0.167)" protocol="none"
remoteServer="" remotePath="" user="" pwd="" progress="5" type="blade-controller"
secureBoot="enabled" status="modified"/>
</outConfig>
</configConfMo>
Updating BIOS Firmware
Request:
<configConfMo cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/bios/fw-updatable">
<inConfig>
<firmwareUpdatable adminState="trigger" dn="sys/rack-unit-1/bios/fw-updatable"
protocol="tftp" remoteServer="10.10.10.10" remotePath="BIOS-2-0-12-9.cap"
type="blade-bios"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/bios/fw-updatable"
cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c" response="yes">
<outConfig>
<firmwareUpdatable dn="sys/rack-unit-1/bios/fw-updatable"
description="BIOS firmware version" adminState="triggered" deployment="primary"
operState="updating" version="server-name.2.0.12.3.031720160046 " protocol="none"
remoteServer="" remotePath="" user="" pwd="" progress="Image Download (5 %), OK"
type="blade-bios" status="modified"/>
</outConfig>
</configConfMo>
The preceding Cisco IMC and BIOS firmware upgrade examples use tftp as the protocol, similarly you can use other available protocols, such as ftp, sftp, scp and http. When you use the sftp, ftp or scp protocol while updating, username and password has to be specified in the input parameters.
Using Non-Interactive HUU to Update Firmware on all C-Series Server Components
Request:
<configConfMo cookie="0000020175/b2909140-0004-1004-8002-cdac38e14388"
inHierarchical="true" dn='sys/huu/firmwareUpdater'>
<inConfig>
<huuFirmwareUpdater dn='sys/huu/firmwareUpdater' adminState='trigger'
remoteIp='10.xxx.xxx.99' remoteShare='/home/xxxxxx/ucs-Cxxx-huu-1.5.0.67.iso'
mapType='cifs' username='user' password='pwd' stopOnError='yes'
timeOut='25' verifyUpdate='yes' updateComponent='all' />
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/bios/fw-updatable"
cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c" response="yes">
<outConfig>
<firmwareUpdatable dn="sys/rack-unit-1/bios/fw-updatable" description="BIOS firmware version"
adminState="triggered" deployment="primary" operState="updating"
version="server-name.2.0.12.3.031720160046 " protocol="none" remoteServer="" remotePath=""
user="" pwd="" progress="Image Download (5 %), OK" type="blade-bios" status="modified"/>
</outConfig>
</configConfMo>
The preceding example initiates and updates the firmware on all components of the server, you can periodically run the following request to check the status of the update:
Status request:
<configResolveClass cookie="1360030993/e4404760-d4f0-14f0-8004-1ec9e1a85750"
inHierarchical="true" classId="huuFirmwareUpdater">
Response:
<configResolveClass cookie="1360030993/e4404760-d4f0-14f0-8004-1ec9e1a85750" response="yes"
classId="huuFirmwareUpdater">
<outConfigs>
<huuFirmwareUpdater dn="sys/huu/firmwareUpdater" adminState="triggered"
remoteIp="http://10.xxx.xxx.99" remoteSharePath="/home/xxxx/ucs-Cxxx-huu-1.5.0.67.iso"
remoteShareFile="ucs-Cxxx-huu-1.5.0.67.iso" mapType="cifs"username="user"
password="pwd" stopOnError="yes" timeOut="25" verifyUpdate="no" updateComponent="all" >
<huuFirmwareUpdateStatus rn="updateStatus"
overallStatus="CIMC,LOM,PCI,STORAGE update successful. BIOS update in progress."
currentTime="Tue Feb 5 02:48:42 2013" updateStartTime="Tue Feb 5 02:28:06 2013"
updateEndTime="NA" >
<huuUpdateComponentStatus component="CIMC" description="CIMC" slot="NA"
runningVersion="1.5(0.69)" newVersion="1.5(0.67)" macAddr="NA"
vendorId="NA" deviceId="NA" subVendorId="NA" subDeviceId="NA" cntrlId="0"
updateStatus="Completed" errorDescription="NA" verifyStatus="NA"
rn="component-CIMC" >
<huuUpdateComponentStatus component="LOM" description="I350" slot="NA"
runningVersion="1.61-02.12-2.7.111-1.3.98-5.1.01-2.7.111"
newVersion="1.61-02.12-2.7.111-1.3.98-5.1.01-2.7.111" macAddr="5057A8E1C922"
vendorId="8086" deviceId="1521" subVendorId="1137" subDeviceId="008A"
cntrlId="0" updateStatus="Completed" errorDescription="NA"
verifyStatus="NA" rn="component-LOM" >
<huuUpdateComponentStatus component="STORAGE" description="2008M-8i" slot="M"
runningVersion="2.130.364-2185" newVersion="2.130.364-2185" macAddr="NA"
vendorId="NA" deviceId="NA" subVendorId="NA" subDeviceId="NA" cntrlId="0"
updateStatus="Completed" errorDescription="NA" verifyStatus="NA"
rn="component-STORAGE" >
<huuUpdateComponentStatus component="PCI" description="UCS VIC 1225" slot="1"
runningVersion="2.1(1.110)-uboot-2.1(1.110)" newVersion="2.1(1.108)-uboot-2.1(1.108)"
macAddr="0200544D474D" vendorId="1137" deviceId="0042" subVendorId="1137"
subDeviceId="0085" cntrlId="0" updateStatus="Completed" errorDescription="NA"
verifyStatus="NA" rn="component-PCI" >
<huuUpdateComponentStatus component="BIOS" description="BIOS" slot="NA"
runningVersion="CxxxMx.1.5.1c.0.013120130456"
newVersion="CxxxMx.1.5.1b.0.012720130527" macAddr="NA" vendorId="NA" deviceId="NA"
subVendorId="NA" subDeviceId="NA" cntrlId="0" updateStatus="InProgress"
errorDescription="NA" verifyStatus="NA" rn="component-BIOS" >
</huuFirmwareUpdateStatus>
</huuFirmwareUpdater>
</outConfigs>
</configResolveClass>
Note |
You can choose a specific components in the updateComponent ' ' parameter to update the firmware only for that component. |
Using TFTP to Import VIC Adapter Configuration Data
Request:
<configConfMo cookie="cookiecutter" inHierarchical="true"
dn="sys/rack-unit-1/adaptor-MLOM/import-config">
<inConfig>
<adaptorCfgImporter dn="sys/rack-unit-1/adaptor-MLOM/import-config"
adminState="trigger" proto="tftp" hostname="10.10.10.10" remoteFile="tftpapi.xml"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-MLOM/import-config"
cookie="0000008008/5c0d9f7e-0002-1002-8003-ac7c7d74a254" response="yes">
<outConfig>
<adaptorCfgImporter dn="sys/rack-unit-1/adaptor-MLOM/import-config"
adminState="triggered" descr="import-config" proto="none" hostname="" remoteFile=""
user="" pwd="" progress="Done" status="modified"/>
</outConfig>
</configConfMo>
Using TFTP to Update VIC Firmware
Request:
<configConfMo cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable">
<inConfig>
<firmwareUpdatable adminState="trigger" dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable"
protocol="tftp" remoteServer="10.10.10.10" remotePath="cruzfw1.bin" type="adaptor"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable"
cookie="0000286104/a1778199-0042-1042-8003-7e573e8f835c" response="yes">
<outConfig>
<firmwareUpdatable dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable"
description="Cisco VIC adapter backup firmware version" adminState="triggered"
deployment="backup" operState="Idle" version="4.1(1d)" protocol="none" remoteServer=""
remotePath="" user="" pwd="" progress="Stage: No operation (0%), Status: Idle, Error: No error"
type="adaptor" status="modified"/>
</outConfig>
</configConfMo>
The preceding example initiates and updates the firmware on VIC, you can periodically run the following request to check the status of the update:
Status request:
<configResolveDn cookie="1350860496/b80c15e8-cc99-1c99-8011-1fc9e1a85750"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable"/>
Status response after completion:
<configResolveDn cookie="1350860496/b80c15e8-cc99-1c99-8011-1fc9e1a85750" response="yes"
dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable">
<outConfig>
<firmwareUpdatable dn="sys/rack-unit-1/adaptor-1/mgmt/fw-updatable" adminState="triggered"
deployment="backup" version="2.x(0.xxx)" protocol="tftp" remoteServer="" remotePath=""
user="" pwd="" progress="Successful" type="adaptor" >
</firmwareUpdatable>
</outConfig>
</configResolveDn>
Configuring VIC Adapter Parameters
Request:
<configConfMo cookie="0000356151/3380bf82-0053-1053-8004-7e573e8f835c" inHierarchical="true" dn="sys/rack-unit-1/adaptor-1">
<inConfig>
<adaptorUnit id="1" description="SL1-PP-System" adminState="adaptor-reset-default" dn="sys/rack-unit-1/adaptor-1">
<adaptorGenProfile dn="sys/rack-unit-1/adaptor-1/general" fipMode="enabled" vntagMode="enabled" numOfVMFexIfs="10"/>
</adaptorUnit>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1" cookie="0000356151/3380bf82-0053-1053-8004-7e573e8f835c"
response="yes">
<outConfig>
<adaptorUnit id="1" model="UCSC-MLOM-C10T-02" pciAddr="1" pciSlot="1" presence="equipped"
serial="FCH19267ENR" description="SL1-PP-System" adminState="policy" cimcManagementEnabled="no"
vendor="Cisco Systems Inc" dn="sys/rack-unit-1/adaptor-1" status="modified">
<adaptorGenProfile rn="general" pciSlot="1" productName="UCS VIC 1227T" model="UCSC-MLOM-C10T-02"
serial="FCH19267ENR" revision="2" fipMode="Enabled" vntagMode="Enabled" lldp="Enabled"
iscsiBootSupported="True" usnicSupported="True" configurationPending="yes" numOfVMFexIfs="10"
vendorId="V01" vendor="Cisco Systems Inc" status="modified"/>
<mgmtController rn="mgmt" model="UCSC-MLOM-C10T-02" serial="FCH19267ENR" subject="adaptor"
vendor="Cisco Systems Inc" status="modified">
<firmwareRunning rn="fw-boot-loader" description="Cisco VIC adapter currently running boot loader firmware version"
deployment="boot-loader" type="adaptor" version="4.0(5b)" status="modified"/>
<firmwareRunning rn="fw-system" description="Cisco VIC adapter currently running firmware version"
deployment="system" type="adaptor" version="4.1(1.47)" status="modified"/>
<firmwareUpdatable rn="fw-updatable" description="Cisco VIC adapter backup firmware version"
adminState="triggered" deployment="backup" operState="Idle" version="4.1(1d)" protocol="none"
remoteServer="" remotePath="" user="" pwd="" progress="Stage: No operation (0%), Status: Idle,
Error: No error" type="adaptor" status="modified"/>
<firmwareBootDefinition rn="fw-boot-def" type="adaptor" status="modified">
<firmwareBootUnit rn="bootunit-combined" description="Cisco VIC adapter startup firmware version"
adminState="triggered" image="running" resetOnActivate="no" type="combined" version="4.1(1.47)" status="modified"/>
</firmwareBootDefinition>
</mgmtController>
<adaptorExtEthIf portId="0" ifType="physical" linkState="down" mac="18:8B:9D:72:93:46"
transport="CE" adminSpeed="10Gbps" operSpeed="-" rn="ext-eth-0" status="modified">
<adaptorConnectorInfo rn="connector-info" present="N/A" supported="N/A" type="N/A"
vendor="N/A" partNumber="N/A" partRevision="N/A" status="modified"/>
<adaptorLinkTraining rn="link-training" linkTraining="n/a" status="modified"/>
<adaptorPortProfiles rn="port-profiles" portProfilesCount="0" portProfilesName="" status="modified"/>
</adaptorExtEthIf>
<adaptorExtEthIf portId="1" ifType="physical" linkState="down" mac="18:8B:9D:72:93:47"
transport="CE" adminSpeed="10Gbps" operSpeed="-" rn="ext-eth-1" status="modified">
<adaptorConnectorInfo rn="connector-info" present="N/A" supported="N/A" type="N/A"
vendor="N/A" partNumber="N/A" partRevision="N/A" status="modified"/>
<adaptorLinkTraining rn="link-training" linkTraining="n/a" status="modified"/>
<adaptorPortProfiles rn="port-profiles" portProfilesCount="0" portProfilesName="" status="modified"/>
</adaptorExtEthIf>
<adaptorHostEthIf name="eth0" cdn="VIC-1-eth0" ifType="virtual" mac="18:8B:9D:72:93:52" mtu="1500"
pxeBoot="disabled" iscsiBoot="disabled" usnicCount="0" uplinkPort="0" classOfService="N/A"
channelNumber="1" portProfile="" rn="host-eth-eth0" status="modified">
<adaptorEthGenProfile rn="general" vmq="disabled" arfs="disabled" uplinkFailover="Disabled"
uplinkFailbackTimeout="5" order="ANY" trustedClassOfService="disabled" rateLimit="N/A" vlan="N/A"
vlanMode="N/A" status="modified"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5" ringSize="1" status="modified"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled" status="modified"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="512" status="modified"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled" status="modified"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled" status="modified"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256" status="modified"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="enabled" status="modified"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled" status="modified"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125"
count="8" mode="MSIx" status="modified"/>
</adaptorHostEthIf>
<adaptorHostEthIf name="eth1" cdn="VIC-1-eth1" ifType="virtual" mac="18:8B:9D:72:93:53"
mtu="1500" pxeBoot="disabled" iscsiBoot="disabled" usnicCount="0" uplinkPort="1" classOfService="N/A"
channelNumber="2" portProfile="" rn="host-eth-eth1" status="modified">
<adaptorEthGenProfile rn="general" vmq="disabled" arfs="disabled" uplinkFailover="Disabled"
uplinkFailbackTimeout="5" order="ANY" trustedClassOfService="disabled" rateLimit="N/A" vlan="N/A"
vlanMode="N/A" status="modified"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5" ringSize="1" status="modified"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled" status="modified"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="512" status="modified"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled" status="modified"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled" status="modified"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256" status="modified"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="enabled" status="modified"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled" status="modified"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125"
count="8" mode="MSIx" status="modified"/>
</adaptorHostEthIf>
<adaptorHostFcIf name="fc0" ifType="virtual" wwnn="10:00:18:8B:9D:72:93:54"
wwpn="20:00:18:8B:9D:72:93:54" uplinkPort="0" sanBoot="disabled" channelNumber="3" portProfile=""
adminPersistentBindings="policy" rn="host-fc-fc0" status="modified">
<adaptorFcGenProfile rn="general" mac="18:8B:9D:72:93:54" order="ANY" classOfService="N/A"
rateLimit="N/A" vlan="NONE" persistentLunBind="disabled" maxDataFieldSize="2112" status="modified"/>
<adaptorFcErrorRecoveryProfile rn="fc-err-rec" errorDetectTimeout="2000" fcpErrorRecovery="disabled"
linkDownTimeout="30000" portDownIoRetryCount="8" portDownTimeout="10000" resourceAllocationTimeout="10000"
ioTimeoutRetry="5" status="modified"/>
<adaptorFcInterruptProfile rn="fc-int" mode="MSIx" status="modified"/>
<adaptorFcPortFLogiProfile rn="fc-port-flogi" retries="INFINITE" timeout="2000" status="modified"/>
<adaptorFcPortPLogiProfile rn="fc-port-plogi" retries="8" timeout="2000" status="modified"/>
<adaptorFcPortProfile rn="fc-port" ioThrottleCount="512" lunsPerTarget="256" lunQueueDepth="20" status="modified"/>
<adaptorFcRecvQueueProfile rn="fc-rcv-q" ringSize="64" status="modified"/>
<adaptorFcWorkQueueProfile rn="fc-work-q" ringSize="64" status="modified"/>
<adaptorFcCdbWorkQueueProfile rn="fc-cdb-work-q" count="1" ringSize="512" status="modified"/>
</adaptorHostFcIf>
<adaptorHostFcIf name="fc1" ifType="virtual" wwnn="10:00:18:8B:9D:72:93:55" wwpn="20:00:18:8B:9D:72:93:55"
uplinkPort="1" sanBoot="disabled" channelNumber="4" portProfile="" adminPersistentBindings="policy"
rn="host-fc-fc1" status="modified">
<adaptorFcGenProfile rn="general" mac="18:8B:9D:72:93:55" order="ANY" classOfService="N/A"
rateLimit="N/A" vlan="NONE" persistentLunBind="disabled" maxDataFieldSize="2112" status="modified"/>
<adaptorFcErrorRecoveryProfile rn="fc-err-rec" errorDetectTimeout="2000" fcpErrorRecovery="disabled"
linkDownTimeout="30000" portDownIoRetryCount="8" portDownTimeout="10000" resourceAllocationTimeout="10000"
ioTimeoutRetry="5" status="modified"/>
<adaptorFcInterruptProfile rn="fc-int" mode="MSIx" status="modified"/>
<adaptorFcPortFLogiProfile rn="fc-port-flogi" retries="INFINITE" timeout="2000" status="modified"/>
<adaptorFcPortPLogiProfile rn="fc-port-plogi" retries="8" timeout="2000" status="modified"/>
<adaptorFcPortProfile rn="fc-port" ioThrottleCount="512" lunsPerTarget="256" lunQueueDepth="20" status="modified"/>
<adaptorFcRecvQueueProfile rn="fc-rcv-q" ringSize="64" status="modified"/>
<adaptorFcWorkQueueProfile rn="fc-work-q" ringSize="64" status="modified"/>
<adaptorFcCdbWorkQueueProfile rn="fc-cdb-work-q" count="1" ringSize="512" status="modified"/>
</adaptorHostFcIf>
<adaptorVMFexEthIf name="pts0" ifType="virtual" mtu="1500" uplinkPort="0" classOfService="N/A"
pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled" uplinkFailbackTimeout="5"
rn="vmfex-eth-pts0" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts0" trustedClassOfService="disabled" pciOrder="19"
completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN" coalescingTime="125"
interruptCount="6" interruptMode="MSI" largeReceive="enabled" tcpRxChecksum="enabled" tcpSegment="enabled"
tcpTxChecksum="enabled" receiveQueueCount="4" receiveQueueRingSize="512" receiveSideScaling="enabled"
receiveSideScalingIpV4Hash="enabled" receiveSideScalingTCPIpV4Hash="enabled"
receiveSideScalingIpV6Hash="enabled" receiveSideScalingTCPIpV6Hash="enabled"
receiveSideScalingExtIpV6Hash="disabled" receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1"
transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts1" ifType="virtual" mtu="1500" uplinkPort="1" classOfService="N/A"
pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled" uplinkFailbackTimeout="5"
rn="vmfex-eth-pts1" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts1" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts2" ifType="virtual" mtu="1500" uplinkPort="0" classOfService="N/A"
pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled" uplinkFailbackTimeout="5"
rn="vmfex-eth-pts2" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts2" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4" receiveQueueRingSize="512"
receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled" receiveSideScalingTCPIpV4Hash="enabled"
receiveSideScalingIpV6Hash="enabled" receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts3" ifType="virtual" mtu="1500" uplinkPort="1" classOfService="N/A"
pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled" uplinkFailbackTimeout="5"
rn="vmfex-eth-pts3" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts3" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts4" ifType="virtual" mtu="1500" uplinkPort="0"
classOfService="N/A" pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled"
uplinkFailbackTimeout="5" rn="vmfex-eth-pts4" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts4" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4" receiveQueueRingSize="512"
receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled" receiveSideScalingTCPIpV4Hash="enabled"
receiveSideScalingIpV6Hash="enabled" receiveSideScalingTCPIpV6Hash="enabled"
receiveSideScalingExtIpV6Hash="disabled" receiveSideScalingExtTCPIpV6Hash="disabled"
transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts5" ifType="virtual" mtu="1500" uplinkPort="1"
classOfService="N/A" pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled"
uplinkFailbackTimeout="5" rn="vmfex-eth-pts5" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts5" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts6" ifType="virtual" mtu="1500" uplinkPort="0"
classOfService="N/A" pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled"
uplinkFailbackTimeout="5" rn="vmfex-eth-pts6" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts6" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts7" ifType="virtual" mtu="1500" uplinkPort="1" classOfService="N/A"
pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled" uplinkFailbackTimeout="5"
rn="vmfex-eth-pts7" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts7" trustedClassOfService="disabled"
pciOrder="19" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts8" ifType="virtual" mtu="1500" uplinkPort="0"
classOfService="N/A" pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled"
uplinkFailbackTimeout="5" rn="vmfex-eth-pts8" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts8" trustedClassOfService="disabled"
pciOrder="20" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorVMFexEthIf name="pts9" ifType="virtual" mtu="1500" uplinkPort="1"
classOfService="N/A" pxeBoot="disabled" vlan="N/A" vlanMode="N/A" uplinkFailover="Enabled"
uplinkFailbackTimeout="5" rn="vmfex-eth-pts9" status="modified">
<adaptorVMFexEthProfile rn="vmfexprofile" name="pts9" trustedClassOfService="disabled"
pciOrder="20" completionQueueCount="5" completionQueueRingSize="1" coalescingType="MIN"
coalescingTime="125" interruptCount="6" interruptMode="MSI" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled" receiveQueueCount="4"
receiveQueueRingSize="512" receiveSideScaling="enabled" receiveSideScalingIpV4Hash="enabled"
receiveSideScalingTCPIpV4Hash="enabled" receiveSideScalingIpV6Hash="enabled"
receiveSideScalingTCPIpV6Hash="enabled" receiveSideScalingExtIpV6Hash="disabled"
receiveSideScalingExtTCPIpV6Hash="disabled" transmitQueueCount="1" transmitQueueRingSize="256" status="modified"/>
</adaptorVMFexEthIf>
<adaptorCfgImporter rn="import-config" adminState="triggered" descr="import-config"
proto="none" hostname="" remoteFile="" user="" pwd="" progress="Done" status="modified"/>
<adaptorCfgBackup rn="export-config" adminState="triggered" descr="export-config"
proto="none" hostname="" remoteFile="" user="" pwd="" progress="Done" status="modified"/>
</adaptorUnit>
</outConfig>
</configConfMo>
Retrieving VIC Adapter General Profile Details
Request:
<configResolveClass cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
inHierarchical="true" classId="adaptorGenProfile"/>
Response:
<configResolveClass cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
response="yes" classId="adaptorGenProfile">
<outConfigs>
<adaptorGenProfile dn="sys/rack-unit-1/adaptor-1/general" pciSlot="1"
productName="UCS VIC 1227T" model="UCSC-MLOM-C10T-02" serial="FCH19267ENR"
revision="2" fipMode="Enabled" vntagMode="Enabled" lldp="Enabled"
iscsiBootSupported="True" usnicSupported="True" configurationPending="yes"
numOfVMFexIfs="10" vendorId="V01" vendor="Cisco Systems Inc"/>
</outConfigs>
</configResolveClass>
Retrieving VIC Adapter Uplink Port Details
Request:
<configResolveClass cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
inHierarchical="true" classId="adaptorExtEthIf"/>
Response:
<configResolveClass cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
response="yes" classId="adaptorExtEthIf">
<outConfigs>
<adaptorExtEthIf portId="0" ifType="physical" linkState="down"
mac="18:8B:9D:72:93:46" transport="CE" adminSpeed="10Gbps"
operSpeed="-" dn="sys/rack-unit-1/adaptor-1/ext-eth-0">
<adaptorConnectorInfo rn="connector-info" present="N/A" supported="N/A" type="N/A"
vendor="N/A" partNumber="N/A" partRevision="N/A"/>
<adaptorLinkTraining rn="link-training" linkTraining="n/a"/>
<adaptorPortProfiles rn="port-profiles" portProfilesCount="0" portProfilesName=""/>
</adaptorExtEthIf>
<adaptorExtEthIf portId="1" ifType="physical" linkState="down" mac="18:8B:9D:72:93:47"
transport="CE" adminSpeed="10Gbps" operSpeed="-" dn="sys/rack-unit-1/adaptor-1/ext-eth-1">
<adaptorConnectorInfo rn="connector-info" present="N/A" supported="N/A" type="N/A"
vendor="N/A" partNumber="N/A" partRevision="N/A"/>
<adaptorLinkTraining rn="link-training" linkTraining="n/a"/>
<adaptorPortProfiles rn="port-profiles" portProfilesCount="0" portProfilesName=""/>
</adaptorExtEthIf>
</outConfigs>
</configResolveClass>
Setting Uplink Port Speed of a VIC Adapter
Request:
<configConfMo cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/ext-eth-0">
<inConfig>
<adaptorExtEthIf portId="0" adminSpeed="10Gbps" dn="sys/rack-unit-1/adaptor-1/ext-eth-0"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/ext-eth-0"
cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c" response="yes">
<outConfig>
<adaptorExtEthIf portId="0" ifType="physical" linkState="down" mac="18:8B:9D:72:93:46"
transport="CE" adminSpeed="10Gbps" operSpeed="-"
dn="sys/rack-unit-1/adaptor-1/ext-eth-0" status="modified">
<adaptorConnectorInfo rn="connector-info" present="N/A" supported="N/A" type="N/A"
vendor="N/A" partNumber="N/A" partRevision="N/A" status="modified"/>
<adaptorLinkTraining rn="link-training" linkTraining="n/a" status="modified"/>
<adaptorPortProfiles rn="port-profiles" portProfilesCount="0" portProfilesName="" status="modified"/>
</adaptorExtEthIf>
</outConfig>
</configConfMo>
Note |
Configuring the speed of an uplink port is supported only for the Cisco UCS VIC1225T Virtual Interface Cards. |
Retrieving Adapter Ethernet Interface Details
Request:
<configResolveClass cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
inHierarchical="true" classId="adaptorHostEthIf"/>
Response:
<configResolveClass cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
response="yes" classId="adaptorHostEthIf">
<outConfigs>
<adaptorHostEthIf name="eth0" cdn="VIC-1-eth0" ifType="virtual"
mac="18:8B:9D:72:93:52" mtu="1500" pxeBoot="disabled" iscsiBoot="disabled"
usnicCount="0" uplinkPort="0" classOfService="N/A" channelNumber="1" portProfile=""
dn="sys/rack-unit-1/adaptor-1/host-eth-eth0">
<adaptorEthGenProfile rn="general" vmq="disabled" arfs="disabled"
uplinkFailover="Disabled" uplinkFailbackTimeout="5" order="ANY" trustedClassOfService="disabled"
rateLimit="N/A" vlan="N/A" vlanMode="N/A"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5" ringSize="1"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="512"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125" count="8" mode="MSIx"/>
</adaptorHostEthIf>
<adaptorHostEthIf name="eth1" cdn="VIC-1-eth1" ifType="virtual" mac="18:8B:9D:72:93:53" mtu="1500"
pxeBoot="disabled" iscsiBoot="disabled" usnicCount="0" uplinkPort="1" classOfService="N/A" channelNumber="2"
portProfile="" dn="sys/rack-unit-1/adaptor-1/host-eth-eth1">
<adaptorEthGenProfile rn="general" vmq="disabled" arfs="disabled" uplinkFailover="Disabled"
uplinkFailbackTimeout="5" order="ANY" trustedClassOfService="disabled" rateLimit="N/A" vlan="N/A" vlanMode="N/A"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5" ringSize="1"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="512"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125" count="8" mode="MSIx"/>
</adaptorHostEthIf>
</outConfigs>
</configResolveClass>
Creating Adapter Ethernet Interface
Request:
<configConfMo cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2">
<inConfig>
<adaptorHostEthIf name="eth2" mac="AUTO" mtu="1500" pxeBoot="disabled" uplinkPort="0"
classOfService="0" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2" status="created">
<adaptorEthGenProfile rn="general" order="ANY" trustedClassOfService="disabled"
rateLimit="OFF" vlan="NONE" vlanMode="TRUNK"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="enabled"
tcpRxChecksum="enabled" tcpSegment="enabled" tcpTxChecksum="enabled"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="512"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125" count="8" mode="MSIx"/>
</adaptorHostEthIf>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/host-eth-eth2"
cookie="0000357041/1800a4e5-0054-1054-8005-7e573e8f835c" response="yes">
<outConfig>
<adaptorHostEthIf name="eth2" cdn="VIC-1-eth2" ifType="virtual"
mac="18:8B:9D:72:93:56" mtu="1500" pxeBoot="disabled" iscsiBoot="disabled"
usnicCount="0" uplinkPort="0" classOfService="0" channelNumber="N/A" portProfile="N/A"
dn="sys/rack-unit-1/adaptor-1/host-eth-eth2" status="created">
<adaptorEthGenProfile rn="general" vmq="disabled" arfs="disabled" uplinkFailover="N/A"
uplinkFailbackTimeout="N/A" order="ANY" trustedClassOfService="disabled" rateLimit="OFF"
vlan="NONE" vlanMode="TRUNK" status="created"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5" ringSize="1" status="created"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="enabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled" status="created"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="512" status="created"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled"
status="created"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled"
tcpHash="disabled" status="created"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256" status="created"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="enabled"
status="created"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled" status="created"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125"
count="8" mode="MSIx" status="created"/>
</adaptorHostEthIf>
</out Config>
</configConfMo>
Modifying Properties of Ethernet Interface
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2">
<inConfig>
<adaptorHostEthIf name="eth2" mac="AUTO" mtu="2222" pxeBoot="enabled"
uplinkPort="0" classOfService="2" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2">
<adaptorEthGenProfile rn="general" order="ANY" trustedClassOfService="disabled"
rateLimit="OFF" vlan="NONE" vlanMode="TRUNK"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="disabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="256"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="disabled"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125" count="8" mode="MSIx"/>
</adaptorHostEthIf>
</inConfig>
</configConfMo>
Response: The highlighted changes should be done, verify the changes in the Cisco IMC or Web user interface.
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/host-eth-eth2"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
<adaptorHostEthIf name="eth2" cdn="VIC-1-eth2" ifType="virtual" mac="18:8B:9D:72:93:56"
mtu="2222" pxeBoot="enabled" iscsiBoot="disabled" usnicCount="0" uplinkPort="0"
classOfService="2" channelNumber="N/A" portProfile="N/A" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2"
status="modified">
<adaptorEthGenProfile rn="general" vmq="disabled" arfs="disabled" uplinkFailover="N/A"
uplinkFailbackTimeout="N/A" order="ANY" trustedClassOfService="disabled" rateLimit="OFF"
vlan="NONE" vlanMode="TRUNK" status="modified"/>
<adaptorEthCompQueueProfile rn="eth-comp-q" count="5" ringSize="1" status="modified"/>
<adaptorEthOffloadProfile rn="eth-offload" largeReceive="disabled" tcpRxChecksum="enabled"
tcpSegment="enabled" tcpTxChecksum="enabled" status="modified"/>
<adaptorEthRecvQueueProfile rn="eth-rcv-q" count="4" ringSize="256" status="modified"/>
<adaptorIpV4RssHashProfile rn="ipv4-rss-hash" ipHash="enabled" tcpHash="enabled" status="modified"/>
<adaptorExtIpV6RssHashProfile rn="ext-ipv6-rss-hash" ipHash="disabled" tcpHash="disabled" status="modified"/>
<adaptorEthWorkQueueProfile rn="eth-work-q" count="1" ringSize="256" status="modified"/>
<adaptorIpV6RssHashProfile rn="ipv6-rss-hash" ipHash="enabled" tcpHash="disabled" status="modified"/>
<adaptorRssProfile rn="rss" receiveSideScaling="enabled" status="modified"/>
<adaptorEthInterruptProfile rn="eth-int" coalescingType="MIN" coalescingTime="125" count="8"
mode="MSIx" status="modified"/>
</adaptorHostEthIf>
</outConfig>
</configConfMo>
Deleting Ethernet Interface
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2">
<inConfig>
<adaptorHostEthIf name="eth2" mac="AUTO" mtu="2222" pxeBoot="enabled"
uplinkPort="0" classOfService="2" dn="sys/rack-unit-1/adaptor-1/host-eth-eth2" status="deleted"/>
</inConfig>
</configConfMo>
This deletes the chosen ethernet interface.
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/host-eth-eth2"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
</outConfig>
</configConfMo>
Retrieving Adapter Fibre Channel Interface Details
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" classId="adaptorHostFcIf"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="adaptorHostFcIf">
<outConfigs>
<adaptorHostFcIf name="fc0" ifType="virtual" wwnn="10:00:18:8B:9D:72:93:54"
wwpn="20:00:18:8B:9D:72:93:54" uplinkPort="0" sanBoot="disabled" channelNumber="N/A"
portProfile="N/A" adminPersistentBindings="policy" dn="sys/rack-unit-1/adaptor-1/host-fc-fc0">
<adaptorFcGenProfile rn="general" mac="18:8B:9D:72:93:54" order="ANY" classOfService="3"
rateLimit="OFF" vlan="NONE" persistentLunBind="disabled" maxDataFieldSize="2112"/>
<adaptorFcErrorRecoveryProfile rn="fc-err-rec" errorDetectTimeout="2000"
fcpErrorRecovery="disabled" linkDownTimeout="30000" portDownIoRetryCount="8"
portDownTimeout="10000" resourceAllocationTimeout="10000" ioTimeoutRetry="5"/>
<adaptorFcInterruptProfile rn="fc-int" mode="MSIx"/>
<adaptorFcPortFLogiProfile rn="fc-port-flogi" retries="INFINITE" timeout="2000"/>
<adaptorFcPortPLogiProfile rn="fc-port-plogi" retries="8" timeout="2000"/>
<adaptorFcPortProfile rn="fc-port" ioThrottleCount="512" lunsPerTarget="256" lunQueueDepth="20"/>
<adaptorFcRecvQueueProfile rn="fc-rcv-q" ringSize="64"/>
<adaptorFcWorkQueueProfile rn="fc-work-q" ringSize="64"/>
<adaptorFcCdbWorkQueueProfile rn="fc-cdb-work-q" count="1" ringSize="512"/>
</adaptorHostFcIf>
<adaptorHostFcIf name="fc1" ifType="virtual" wwnn="10:00:18:8B:9D:72:93:55"
wwpn="20:00:18:8B:9D:72:93:55" uplinkPort="1" sanBoot="disabled" channelNumber="N/A"
portProfile="N/A" adminPersistentBindings="policy"
dn="sys/rack-unit-1/adaptor-1/host-fc-fc1">
<adaptorFcGenProfile rn="general" mac="18:8B:9D:72:93:55" order="ANY" classOfService="3" rateLimit="OFF"
vlan="NONE" persistentLunBind="disabled" maxDataFieldSize="2112"/>
<adaptorFcErrorRecoveryProfile rn="fc-err-rec" errorDetectTimeout="2000" fcpErrorRecovery="disabled"
linkDownTimeout="30000" portDownIoRetryCount="8" portDownTimeout="10000" resourceAllocationTimeout="10000" ioTimeoutRetry="5"/>
<adaptorFcInterruptProfile rn="fc-int" mode="MSIx"/>
<adaptorFcPortFLogiProfile rn="fc-port-flogi" retries="INFINITE" timeout="2000"/>
<adaptorFcPortPLogiProfile rn="fc-port-plogi" retries="8" timeout="2000"/>
<adaptorFcPortProfile rn="fc-port" ioThrottleCount="512" lunsPerTarget="256" lunQueueDepth="20"/>
<adaptorFcRecvQueueProfile rn="fc-rcv-q" ringSize="64"/>
<adaptorFcWorkQueueProfile rn="fc-work-q" ringSize="64"/>
<adaptorFcCdbWorkQueueProfile rn="fc-cdb-work-q" count="1" ringSize="512"/>
</adaptorHostFcIf>
</outConfigs>
</configResolveClass>
Creating Boot Entry for a Fibre Channel Interface
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/adaptor-1/host-fc-fc0/fcboot-0">
<inConfig>
<adaptorFcBootTable dn="sys/rack-unit-1/adaptor-1/host-fc-fc0/fcboot-0"
targetWwpn="20:11:22:33:44:55:66:78" bootLun="1" status="created"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/host-fc-fc0/fcboot-0"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
<adaptorFcBootTable index="0" targetWwpn="20:11:22:33:44:55:66:78" bootLun="1"
dn="sys/rack-unit-1/adaptor-1/host-fc-fc0/fcboot-0" status="created"/>
</outConfig>
</configConfMo>
Configuring HUU for One-Time Boot
Request:
<configConfMo cookie='1342064443/ba6bccf0-c499-1499-8002-134c9ee53d50'
inHierarchical='false' dn='sys/rack-unit-1/boot-one-time' >
<inConfig>
<oneTimeBootDevice device='huu' dn='sys/rack-unit-1/boot-one-time'>
</oneTimeBootDevice>
</inConfig>
</configConfMo>
You can verify this in the user interface. Similar to this example, you can also set SCU and HV as one-time boot devices.
Mounting Share to the VMedia with Username
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="false" dn="sys/svc-ext/vmedia-svc/vmmap-WIN7">
<inConfig>
<commVMediaMap map="nfs" dn="sys/svc-ext/vmedia-svc/vmmap-WIN7"
volumeName="WIN7" remoteShare="10.10.10.10:/nfs" remoteFile="sl1huu.iso"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/svc-ext/vmedia-svc/vmmap-WIN7"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
<commVMediaMap volumeName="WIN7" map="nfs" remoteShare="10.10.10.10:/nfs"
remoteFile="sl1huu.iso" mountOptions="nolock,noexec,soft,timeo=100,retry=2,rsize=3072,wsize=3072"
mappingStatus="ERROR: mounting 10.10.10.10:/nfs failed: Permission denied " password=""
dn="sys/svc-ext/vmedia-svc/vmmap-WIN7" status="created"/>
</outConfig>
</configConfMo>
Mounting Share to the VMedia Without the Username
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
dn="sys/svc-ext/vmedia-svc/vmmap-Win12" inHierarchical="false">
<inConfig>
<commVMediaMap dn="sys/svc-ext/vmedia-svc/vmmap-Win12" map="www"
mountOptions="username=,password=" remoteFile="en_windows_server_2012_x64_dvd_915478.iso"
remoteShare="http://10.10.10.10/" status="created" volumeName="Win12"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/svc-ext/vmedia-svc/vmmap-Win12"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
<commVMediaMap volumeName="Win12" map="www" remoteShare="http://10.10.10.10/"
remoteFile="en_windows_server_2012_x64_dvd_915478.iso" mountOptions="noauto,
username=,password=" mappingStatus="ERROR: mount.httpfs2: HEAD: reply didn't contain Content-Length! "
password="" dn="sys/svc-ext/vmedia-svc/vmmap-Win12" status="created"/>
</outConfig>
</configConfMo>
Setting Remotesyslog Primary Server
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="false" dn="sys/svc-ext/syslog/client-primary">
<inConfig>
<commSyslogClient name="primary" adminState="enabled"
hostname="10.xxx.196.xxx" port="900" dn="sys/svc-ext/syslog/client-primary"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/svc-ext/syslog/client-primary"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
<commSyslogClient adminState="enabled" hostname="10.xxx.196.xxx"
name="primary" port="900" adminAction="no-op"
dn="sys/svc-ext/syslog/client-primary" status="modified"/>
</outConfig>
</configConfMo>
Setting Remotesyslog Secondary Server
Request:
<configConfMo cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="false" dn="sys/svc-ext/syslog/client-secondary">
<inConfig>
<commSyslogClient name="secondary" adminState="enabled"
hostname="10.xxx.195.xxx"
port="900" dn="sys/svc-ext/syslog/client-secondary"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/svc-ext/syslog/client-secondary"
cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c" response="yes">
<outConfig>
<commSyslogClient adminState="enabled" hostname="10.xxx.195.xxx"
name="secondary" port="900" adminAction="no-op"
dn="sys/svc-ext/syslog/client-secondary" status="modified"/>
</outConfig>
</configConfMo>
Retrieving Syslog Client-Server Details
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="false" classId="commSyslogClient"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="commSyslogClient">
<outConfigs>
<commSyslogClient adminState="enabled" hostname="10.xxx.196.xxx" name="primary"
port="900" adminAction="no-op" dn="sys/svc-ext/syslog/client-primary"/>
<commSyslogClient adminState="enabled" hostname="10.xxx.195.xxx" name="secondary"
port="900" adminAction="no-op" dn="sys/svc-ext/syslog/client-secondary"/>
</outConfigs>
</configResolveClass>
Retrieving LOM MAC Address Support Details
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
classId="networkAdapterUnit" inHierarchical="false"/>
Response:
<configResolveClass cookie="1270945253/00566da0-83eb-13eb-8002-98219ee53d50" response="yes"
classId="networkAdaptorUnit">
<outConfigs>
<networkAdaptorUnit slot="1" model="Broadcom 57712-S" numIntf="2"
dn="sys/rack-unit-1/network-adaptor-1" > </networkAdaptorUnit>
<networkAdaptorUnit slot="2" model="Broadcom 57711 1" numIntf="2"
dn="sys/rack-unit-1/network-adaptor-2" > </networkAdaptorUnit>
<networkAdaptorUnit slot="L" model="Intel Onboard 1Gbps Ethernet Adapter" numIntf="2"
dn="sys/rack-unit-1/network-adaptor-L" >
</networkAdaptorUnit>
</outConfigs></configResolveClass>
Retrieving MAC Address of Individual Ports of Network Controllers
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" classId="networkAdapterEthIf"/>
Response:
<configResolveClass cookie='1347541314/e95cea30-c994-1994-80ac-0877e1a85750'response="yes"
dn="sys/rack-unit-1/network-adaptor-1">
<outConfigs>
<networkAdaptorEthIf id="1" mac="00:10:18:bf:62:0c" linkStateAtPOST="Down"
dn="sys/rack-unit-1/network-adaptor-1/eth-1" > </networkAdaptorEthIf>
<networkAdaptorEthIf id="2" mac="00:10:18:bf:62:0e" linkStateAtPOST="Down"
dn="sys/rack-unit-1/network-adaptor-1/eth-2" >
</networkAdaptorEthIf>
</outConfigs></configResolveClass>
Retrieving LOM MAC Address of Individual Ports
Request:
<configResolveDn cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" dn="sys/rack-unit-1/network-adapter-L"/>
Response:
<configResolveDn cookie="1270945253/00566da0-83eb-13eb-8002-98219ee53d50" response="yes"
dn="sys/rack-unit-1/network-adaptor-L/eth-1">
<outConfig>
<networkAdaptorEthIf id="1" mac="50:3D:E5:9E:21:9C" linkStateAtPOST="Up"
dn="sys/rack-unit-1/network-adaptor-L/eth-1" >
</networkAdaptorEthIf>
</outConfig>
</configResolveDn>
Retrieving LSI Storage Adapter Summary Properties Installed on C-Series Server
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" classId="storageController"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="storageController">
<outConfigs>
<storageController id="SLOT-MEZZ" pciSlot="SLOT-MEZZ"
presence="equipped" raidSupport="yes" serial="FCH1901JBUX" type="SAS"
vendor="LSI Logic" selfEncryptEnabled="yes" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ">
<storageControllerProps rn="controller-props" pciSlot="SLOT-MEZZ" health="Good"
controllerStatus="Optimal" batteryStatus="Optimal" bbuPresent="true" raidChipTempCentigrade="49"
backendPortCount="8" memorySize="1024 MB" cacheMemorySize="820 MB" virtualDriveCount="1"
degradedVirtualDriveCount="0" offlineVirtualDriveCount="0" physicalDriveCount="15"
criticalPhysicalDriveCount="0" failedPhysicalDriveCount="0" memoryCorrectableErrors="0"
memoryUncorrectableErrors="0" bootDrive="none" bootDriveIsPhysicalDrive="false" supportsRaid0="true"
supportsRaid1="true" supportsRaid5="true" supportsRaid6="true" supportsRaid00="true"
supportsRaid10="true" supportsRaid50="true" supportsRaid60="true" supportsRaid1e="false"
supportsRaid1erlq0="true" supportsRaid1e0rlq0="true" supportsRaidsrl03="true"
dateOfManufacture="2015-01-26" revision="03" prebootCliVersion="01.07-05:#%0000" webBiosVersion="N/A"
nvdataVersion="3.1511.00-0011" bootBlockVersion="3.07.00.00-0003" bootVersion="N/A" nvramPresent="true"
serialDebuggerPresent="true" flashPresent="true" sasAddress0="5188b9d724504b7f" sasAddress1="5188b9d724503a7f"
sasAddress2="0000000000000000" sasAddress3="0000000000000000" sasAddress4="0000000000000000"
sasAddress5="0000000000000000" sasAddress6="0000000000000000" sasAddress7="0000000000000000"
serial="FCH1901JBUX" firmwarePackageBuild="24.12.1-0018" ttyLogStatus="Complete (total size 426675 bytes)"/>
<storageControllerHealth rn="controller-health" id="SLOT-MEZZ" health="Good"/>
<generatedStorageControllerKeyId rn="gen-key-id" generatedKeyId="UCSC-RAID_FCH1901JBUX_c7984572"/>
<suggestedStorageControllerSecurityKey rn="suggested-sec-key" suggestedSecurityKey="itXTMdShfbG6nyXddEoWZjMGd4BV2Ruh"/>
<selfEncryptStorageController rn="ctr-self-encrypt" keyId="test1234" securityKey="Security key"
existingSecurityKey="Existing security key" adminAction="no-op"/>
<storageRaidBattery rn="raid-battery" batteryType="TMM-C SuperCap" health="Good" batteryStatus="Optimal"
batteryPresent="true" chargingState="N/A" temperature="30 degrees C" temperatureHigh="false" designVoltage="9.500 V"
voltage="9.547 V" current="0.000 A" learnMode="Auto" learnCycleStatus="Successful" learnCycleRequested="false"
nextLearnCycle="1970-01-28 22:50" designCapacity="288 Joules" manufacturer="LSI" dateOfManufacture="2014-09-28"
serialNumber="14609" firmwareVersion="6536-03A" adminAction="no-op"/>
<storageVirtualDriveCreatorUsingUnusedPhysicalDrive rn="virtual-drive-create"
description="Create a new virtual drive from unused physical drive(s) available in the rack server.
Children objects of this object, lists all currently available unused physical drives."
minRequiredPhysicalDrives="RAID 0 at least 1 physical drive, RAID 1 at least 2 physical drives,
RAID 5 at least 3 physical drives, RAID 6 at least 3 physical drives, RAID 10 at least 4 physical drives,
RAID 50 or RAID 60 at least 6 physical drives" virtualDriveName="" raidLevel="" size=""
driveGroup="[span1_pd_id1,span1_pd_id2,span1_pd_id3...,span1_pd_idN]
[span2_pd_id1,span2_pd_id2,span2_pd_id3...,span2_pd_idN]..." writePolicy="" stripSize=""
readPolicy="" cachePolicy="" accessPolicy="" diskCachePolicy="" createdVirtualDriveDn=""
operStatus="" adminAction="no-op" adminState="triggered">
<storageUnusedLocalDisk id="3" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-3"/>
<storageUnusedLocalDisk id="4" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-4"/>
<storageUnusedLocalDisk id="5" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-5"/>
<storageUnusedLocalDisk id="6" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-6"/>
<storageUnusedLocalDisk id="8" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-8"/>
<storageUnusedLocalDisk id="9" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-9"/>
<storageUnusedLocalDisk id="10" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-10"/>
<storageUnusedLocalDisk id="11" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-11"/>
<storageUnusedLocalDisk id="12" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-12"/>
<storageUnusedLocalDisk id="13" pdStatus="Unconfigured Good" coercedSize="3814697 MB"
health="Good" mediaType="HDD" vendor="SEAGATE" rn="pd-13"/>
</storageVirtualDriveCreatorUsingUnusedPhysicalDrive>
<storageVirtualDriveCreatorUsingVirtualDriveGroup rn="virtual-drive-carve"
description="Create a new virtual drive from an existing virtual drive, with available physical drive group space.
Children objects of this object, lists all virtual drives with available drive group space."
sharedVirtualDriveId="" virtualDriveName="" size="" writePolicy="" stripSize="" readPolicy=""
cachePolicy="" accessPolicy="" diskCachePolicy="" createdVirtualDriveDn="" operStatus="" adminState="triggered"/>
<storageLocalDisk id="1" pdStatus="Online" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1C0VN0000K5486L16" driveState="Online"
online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-1">
<storageLocalDiskProps rn="general-props" physicalDrive="1" pdStatus="Online" health="Good"
enclosureDeviceId="24" deviceId="15" sequenceNumber="2" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b407b5" sasAddress1="5000c50089b407b6"
physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="2" pdStatus="Online" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023"
driveFirmware="0004" driveSerialNumber="S1Z1C0Y90000K5486G13" driveState="Online" online="true"
dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-2">
<storageLocalDiskProps rn="general-props" physicalDrive="2" pdStatus="Online" health="Good"
enclosureDeviceId="24" deviceId="16" sequenceNumber="2" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089b4002d" sasAddress1="5000c50089b4002e" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="3" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1C0ST0000K5486KJF" driveState="Unconfigured Good"
online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-3">
<storageLocalDiskProps rn="general-props" physicalDrive="3" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="17" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b40c5d"
sasAddress1="5000c50089b40c5e" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="4" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1C0XW0000K5486FYZ"
driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached"
enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0"
locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-4">
<storageLocalDiskProps rn="general-props" physicalDrive="4" pdStatus="Unconfigured Good" health="Good"
enclosureDeviceId="24" deviceId="10" sequenceNumber="1" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b4015d"
sasAddress1="5000c50089b4015e" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="5" pdStatus="Unconfigured Good" health="Good"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD"
coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1C0LG0000K5486KZG" driveState="Unconfigured Good" online="true"
dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-5">
<storageLocalDiskProps rn="general-props" physicalDrive="5" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="13" sequenceNumber="1" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b42465"
sasAddress1="5000c50089b42466" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="6" pdStatus="Unconfigured Good" health="Good"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB"
vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1C0RB0000K5486KXG"
driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached"
enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0"
locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" rn="pd-6">
<storageLocalDiskProps rn="general-props" physicalDrive="6" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="20" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b41215"
sasAddress1="5000c50089b41216" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="7" pdStatus="JBOD" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0063"
driveFirmware="0004" driveSerialNumber="Z1Z8MRC70000R540WM1C" driveState="JBOD" online="true"
dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="yes"
fdeEnabled="yes" secured="yes" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-7">
<storageLocalDiskProps rn="general-props" physicalDrive="7" pdStatus="JBOD" health="Good"
enclosureDeviceId="24" deviceId="26" sequenceNumber="4" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c5008390f455"
sasAddress1="5000c5008390f456" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="8" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z19MEK0000K5474R7B" driveState="Unconfigured Good"
online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached"
enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0"
locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" rn="pd-8">
<storageLocalDiskProps rn="general-props" physicalDrive="8" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="18" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a49f75"
sasAddress1="5000c50089a49f76" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="9" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1AXG20000K5486GFD"
driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached"
enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0"
locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" rn="pd-9">
<storageLocalDiskProps rn="general-props" physicalDrive="9" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="19" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a54ed5"
sasAddress1="5000c50089a54ed6" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="10" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1AE7C0000K5488N1T"
driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off"
fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-10">
<storageLocalDiskProps rn="general-props" physicalDrive="10" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="23" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c5008996c641"
sasAddress1="5000c5008996c642" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="11" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z19LR20000K5474R6W"
driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off"
fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-11">
<storageLocalDiskProps rn="general-props" physicalDrive="11" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="22" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD"
blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a4f409"
sasAddress1="5000c50089a4f40a" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="12" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z192230000K5486HLT"
driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off"
fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-12">
<storageLocalDiskProps rn="general-props" physicalDrive="12" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="21" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c5008996eb51"
sasAddress1="5000c5008996eb52" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="13" pdStatus="Unconfigured Good" health="Good"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD"
coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1B0ME0000K548AJYA" driveState="Unconfigured Good" online="true"
dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-13">
<storageLocalDiskProps rn="general-props" physicalDrive="13" pdStatus="Unconfigured Good"
health="Good" enclosureDeviceId="24" deviceId="12" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c500899670a1"
sasAddress1="5000c500899670a2" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="14" pdStatus="JBOD" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB"
vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z19MLC0000K5473FAP"
driveState="JBOD" online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached"
enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0"
locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" rn="pd-14">
<storageLocalDiskProps rn="general-props" physicalDrive="14" pdStatus="JBOD" health="Good"
enclosureDeviceId="24" deviceId="14" sequenceNumber="2" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089a4916d" sasAddress1="5000c50089a4916e" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation in progress"
progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageLocalDisk id="21" pdStatus="JBOD" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023"
driveFirmware="0004" driveSerialNumber="S1Z19LY80000K5487ZHM" driveState="JBOD" online="true"
dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" rn="pd-21">
<storageLocalDiskProps rn="general-props" physicalDrive="21" pdStatus="JBOD" health="Good"
enclosureDeviceId="24" deviceId="11" sequenceNumber="2" mediaErrorCount="0" otherErrorCount="0"
predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a4d9c9"
sasAddress1="5000c50089a4d9ca" physicalBlockSize="512"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageLocalDisk>
<storageVirtualDrive id="0" name="RAID1_12" raidLevel="RAID 1" size="3814697 MB"
vdStatus="Optimal" health="Good" bootDrive="false" stripSize="256k" drivesPerSpan="2"
spanDepth="1" accessPolicy="read-write" cachePolicy="direct-io" readPolicy="no-read-ahead"
requestedWriteCachePolicy="write-through" currentWriteCachePolicy="write-through" diskCachePolicy="unchanged"
allowBackgroundInit="true" autoSnapshot="false" autoDeleteOldest="true" driveState="Optimal"
fdeCapable="no" fdeEnabled="no" adminAction="no-op" hotspareAction="no-op" targetId="0"
physicalDrivesList="Physical drives to be used for virtual drive reconstruction. pd_id1,pd_id2,...pd_idN" rn="vd-0">
<storageLocalDiskUsage startingBlock="0" numberOfBlocks="7812499456" virtualDrive="0"
physicalDrive="1" state="online" span="0" rn="pd-1"/>
<storageLocalDiskUsage startingBlock="0" numberOfBlocks="7812499456" virtualDrive="0"
physicalDrive="2" state="online" span="0" rn="pd-2"/>
<storageOperation rn="storage-operation" lropInProgress="false"
currentLrop="No operation in progress" progressPercent="0" elapsedSeconds="0"/>
</storageVirtualDrive>
<firmwareRunning rn="fw-boot-loader" description="LSI Storage controller currently running boot
loader firmware version" deployment="boot-loader" type="storage-controller" version="6.30.03.0_4.17.08.00_0xC6130201"/>
<firmwareRunning rn="fw-system" description="LSI Storage controller currently running firmware version"
deployment="system" type="storage-controller" version="4.620.00-6084"/>
<firmwareBootDefinition rn="fw-boot-def" type="storage-controller">
<firmwareBootUnit rn="bootunit-combined" description="LSI Storage controller startup BIOS firmware version"
adminState="triggered" image="running" resetOnActivate="no" type="combined" version="6.30.03.0_4.17.08.00_0xC6130201"/>
</firmwareBootDefinition>
<storageControllerSettings rn="controller-settings" pciSlot="SLOT-MEZZ" predictiveFailPollInterval="300 sec"
rebuildRate="30 %" patrolReadRate="30 %" consistencyCheckRate="30 %" reconstructionRate="30 %"
cacheFlushInterval="4 sec" spinupDriveCount="4" spinupDelay="6 sec" physDriveCoercionMode="1 GB" clusterEnable="false"
batteryWarning="true" eccBucketLeakRate="1440 min" exposeEnclosureDevices="true" maintainPdFailHistory="false"
enableCopybackOnSmart="true" enableCopybackToSsdOnSmartError="true" ncqStatus="enabled" enableJbod="true"
spinDownUnconfigured="true" enableSsdPatrolRead="false" autoEnhancedImport="true"/>
</storageController>
</outConfigs>
</configResolveClass>
Retrieving LSI Storage Adapter Detailed Properties Installed on C-Series Server
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" classId="storageControllerProps"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="storageControllerProps">
<outConfigs>
<storageControllerProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/controller-props"
pciSlot="SLOT-MEZZ" health="Good" controllerStatus="Optimal" batteryStatus="Optimal"
bbuPresent="true" raidChipTempCentigrade="49" backendPortCount="8"
memorySize="1024 MB" cacheMemorySize="820 MB" virtualDriveCount="1"
degradedVirtualDriveCount="0" offlineVirtualDriveCount="0" physicalDriveCount="15"
criticalPhysicalDriveCount="0" failedPhysicalDriveCount="0" memoryCorrectableErrors="0"
memoryUncorrectableErrors="0" bootDrive="none" bootDriveIsPhysicalDrive="false"
supportsRaid0="true" supportsRaid1="true" supportsRaid5="true" supportsRaid6="true"
supportsRaid00="true" supportsRaid10="true" supportsRaid50="true" supportsRaid60="true"
supportsRaid1e="false" supportsRaid1erlq0="true" supportsRaid1e0rlq0="true"
supportsRaidsrl03="true" dateOfManufacture="2015-01-26" revision="03" prebootCliVersion="01.07-05:#%0000"
webBiosVersion="N/A" nvdataVersion="3.1511.00-0011" bootBlockVersion="3.07.00.00-0003" bootVersion="N/A"
nvramPresent="true" serialDebuggerPresent="true" flashPresent="true" sasAddress0="5188b9d724504b7f"
sasAddress1="5188b9d724503a7f" sasAddress2="0000000000000000" sasAddress3="0000000000000000"
sasAddress4="0000000000000000" sasAddress5="0000000000000000" sasAddress6="0000000000000000"
sasAddress7="0000000000000000" serial="FCH1901JBUX" firmwarePackageBuild="24.12.1-0018"
ttyLogStatus="Complete (total size 426675 bytes)"/>
</outConfigs>
</configResolveClass>
Retrieving LSI Storage Adapter Details of RAID Battery
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" classId="storageRaidBattery"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="storageRaidBattery">
<outConfigs>
<storageRaidBattery dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/raid-battery"
batteryType="TMM-C SuperCap" health="Good" batteryStatus="Optimal"
batteryPresent="true" chargingState="N/A" temperature="30 degrees C" temperatureHigh="false"
designVoltage="9.500 V" voltage="9.547 V" current="0.000 A" learnMode="Auto"
learnCycleStatus="Successful" learnCycleRequested="false" nextLearnCycle="1970-01-28 22:50"
designCapacity="288 Joules" manufacturer="LSI" dateOfManufacture="2014-09-28"
serialNumber="14609" firmwareVersion="6536-03A" adminAction="no-op"/>
</outConfigs>
</configResolveClass>
Retrieving Summary Information of Local Disks (HDD)
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="false" classId="storageLocalDisk"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="storageLocalDisk">
<outConfigs>
<storageLocalDisk id="1" pdStatus="Online" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z1C0VN0000K5486L16" driveState="Online"
online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-1"/>
<storageLocalDisk id="2" pdStatus="Online" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023"
driveFirmware="0004" driveSerialNumber="S1Z1C0Y90000K5486G13" driveState="Online" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-2"/>
<storageLocalDisk id="3" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1C0ST0000K5486KJF" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-3"/>
<storageLocalDisk id="4" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1C0XW0000K5486FYZ" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-4"/>
<storageLocalDisk id="5" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1C0LG0000K5486KZG" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-5"/>
<storageLocalDisk id="6" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1C0RB0000K5486KXG" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-6"/>
<storageLocalDisk id="7" pdStatus="JBOD" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0063" driveFirmware="0004"
driveSerialNumber="Z1Z8MRC70000R540WM1C" driveState="JBOD" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="yes" fdeEnabled="yes" secured="yes" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-7"/>
<storageLocalDisk id="8" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z19MEK0000K5474R7B" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-8"/>
<storageLocalDisk id="9" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1AXG20000K5486GFD" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-9"/>
<storageLocalDisk id="10" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1AE7C0000K5488N1T" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-10"/>
<storageLocalDisk id="11" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z19LR20000K5474R6W" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-11"/>
<storageLocalDisk id="12" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE"
productId="ST4000NM0023" driveFirmware="0004" driveSerialNumber="S1Z192230000K5486HLT" driveState="Unconfigured Good"
online="true" dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no"
secured="no" locked="no" foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-12"/>
<storageLocalDisk id="13" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z1B0ME0000K548AJYA" driveState="Unconfigured Good" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no" foreignLocked="no"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-13"/>
<storageLocalDisk id="14" pdStatus="JBOD" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023" driveFirmware="0004"
driveSerialNumber="S1Z19MLC0000K5473FAP" driveState="JBOD" online="true" dedicatedHotSpareForVDId=""
enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000" enclosureSASAddress0="5188b9d724504b7e"
enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no" fdeEnabled="no" secured="no" locked="no"
foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-14"/>
<storageLocalDisk id="21" pdStatus="JBOD" health="Good" predictiveFailureCount="0" linkSpeed="12.0 Gb/s"
interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0023"
driveFirmware="0004" driveSerialNumber="S1Z19LY80000K5487ZHM" driveState="JBOD" online="true"
dedicatedHotSpareForVDId="" enclosureAssociation="Expander Attached" enclosureLogicalId="500e004aaaee0000"
enclosureSASAddress0="5188b9d724504b7e" enclosureSASAddress1="0x0" locatorLEDStatus="off" fdeCapable="no"
fdeEnabled="no" secured="no" locked="no" foreignLocked="no" adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-21"/>
</outConfigs>
</configResolveClass>
Retrieving Detailed Information of Local Disks (HDD)
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="false" classId="storageLocalDiskProps"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="storageLocalDiskProps">
<outConfigs>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-1/general-props"
physicalDrive="1" pdStatus="Online" health="Good" enclosureDeviceId="24" deviceId="15" sequenceNumber="2"
mediaErrorCount="0" otherErrorCount="0" predictiveFailureCount="0"
linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b407b5"
sasAddress1="5000c50089b407b6" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-2/general-props"
physicalDrive="2" pdStatus="Online" health="Good" enclosureDeviceId="24" deviceId="16" sequenceNumber="2"
mediaErrorCount="0" otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b4002d" sasAddress1="5000c50089b4002e"
physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-3/general-props" physicalDrive="3"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="17" sequenceNumber="1"
mediaErrorCount="0" otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089b40c5d"
sasAddress1="5000c50089b40c5e" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-4/general-props" physicalDrive="4"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="10" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089b4015d" sasAddress1="5000c50089b4015e" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-5/general-props" physicalDrive="5"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="13" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089b42465" sasAddress1="5000c50089b42466" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-6/general-props" physicalDrive="6"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="20" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089b41215" sasAddress1="5000c50089b41216" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-7/general-props" physicalDrive="7"
pdStatus="JBOD" health="Good" enclosureDeviceId="24" deviceId="26" sequenceNumber="4" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD"
blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c5008390f455" sasAddress1="5000c5008390f456"
physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-8/general-props" physicalDrive="8"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="18" sequenceNumber="1"
mediaErrorCount="0" otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS"
mediaType="HDD" blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB"
nonCoercedSize="3814935 MB" coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a49f75"
sasAddress1="5000c50089a49f76" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-9/general-props" physicalDrive="9"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="19" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089a54ed5" sasAddress1="5000c50089a54ed6" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-10/general-props" physicalDrive="10"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="23" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c5008996c641" sasAddress1="5000c5008996c642" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-11/general-props" physicalDrive="11"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="22" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c50089a4f409" sasAddress1="5000c50089a4f40a" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-12/general-props" physicalDrive="12"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="21" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c5008996eb51" sasAddress1="5000c5008996eb52" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-13/general-props" physicalDrive="13"
pdStatus="Unconfigured Good" health="Good" enclosureDeviceId="24" deviceId="12" sequenceNumber="1" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD" blockSize="512"
blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB" coercedSize="3814697 MB"
powerState="active" sasAddress0="5000c500899670a1" sasAddress1="5000c500899670a2" physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-14/general-props" physicalDrive="14"
pdStatus="JBOD" health="Good" enclosureDeviceId="24" deviceId="14" sequenceNumber="2" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD"
blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a4916d" sasAddress1="5000c50089a4916e"
physicalBlockSize="512"/>
<storageLocalDiskProps dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/pd-21/general-props" physicalDrive="21"
pdStatus="JBOD" health="Good" enclosureDeviceId="24" deviceId="11" sequenceNumber="2" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="12.0 Gb/s" interfaceType="SAS" mediaType="HDD"
blockSize="512" blockCount="7814037168" bootDrive="false" rawSize="3815447 MB" nonCoercedSize="3814935 MB"
coercedSize="3814697 MB" powerState="active" sasAddress0="5000c50089a4d9c9" sasAddress1="5000c50089a4d9ca"
physicalBlockSize="512"/>
</outConfigs>
</configResolveClass>
Retrieving Details of All Virtual Drives Configured in LSI Adapters
Request:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
inHierarchical="true" classId="storageVirtualDrive"/>
Response:
<configResolveClass cookie="0000360672/c2450e1c-0054-1054-8006-7e573e8f835c"
response="yes" classId="storageVirtualDrive">
<outConfigs>
<storageVirtualDrive id="0" name="RAID1_12" raidLevel="RAID 1" size="3814697 MB"
vdStatus="Optimal" health="Good" bootDrive="false" stripSize="256k"
drivesPerSpan="2" spanDepth="1" accessPolicy="read-write" cachePolicy="direct-io"
readPolicy="no-read-ahead" requestedWriteCachePolicy="write-through"
currentWriteCachePolicy="write-through" diskCachePolicy="unchanged"
allowBackgroundInit="true" autoSnapshot="false" autoDeleteOldest="true"
driveState="Optimal" fdeCapable="no" fdeEnabled="no" adminAction="no-op"
hotspareAction="no-op" targetId="0" physicalDrivesList="Physical drives to be
used for virtual drive reconstruction. pd_id1,pd_id2,...pd_idN"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-MEZZ/vd-0">
<storageLocalDiskUsage startingBlock="0" numberOfBlocks="7812499456" virtualDrive="0"
physicalDrive="1" state="online" span="0" rn="pd-1"/>
<storageLocalDiskUsage startingBlock="0" numberOfBlocks="7812499456" virtualDrive="0"
physicalDrive="2" state="online" span="0" rn="pd-2"/>
<storageOperation rn="storage-operation" lropInProgress="false" currentLrop="No operation
in progress" progressPercent="0" elapsedSeconds="0"/>
</storageVirtualDrive>
</outConfigs>
</configResolveClass>
Retrieving Details of Physical Disks Usage by Virtual Drives
Request:
<configResolveClass cookie="1362107110/46742048-d6d4-16d4-8006-4a45b42d542c"
inHierarchical="false" classId="storageLocalDiskUsage"/>
Response:
<configResolveClass cookie="1362107110/46742048-d6d4-16d4-8006-4a45b42d542c" response="yes"
classId="storageLocalDiskUsage">
<outConfigs>
<storageLocalDiskUsage startingBlock="0" numberOfBlocks="209715200"
virtualDrive="10" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-10/pd-5"/>
<storageLocalDiskUsage startingBlock="209715200" numberOfBlocks="25165824"
virtualDrive="11" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-11/pd-5"/>
<storageLocalDiskUsage startingBlock="234881024" numberOfBlocks="25165824"
virtualDrive="12" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-12/pd-5"/>
<storageLocalDiskUsage startingBlock="260046848" numberOfBlocks="25625088"
virtualDrive="13" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-13/pd-5"/>
<storageLocalDiskUsage startingBlock="285671936" numberOfBlocks="25165824"
virtualDrive="14" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-14/pd-5"/>
<storageLocalDiskUsage startingBlock="310837760" numberOfBlocks="25165824"
virtualDrive="15" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-15/pd-5"/>
<storageLocalDiskUsage startingBlock="336003584" numberOfBlocks="25165824"
virtualDrive="16" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-16/pd-5"/>
<storageLocalDiskUsage startingBlock="361169408" numberOfBlocks="614530560"
virtualDrive="17" physicalDrive="5" state="online" span="0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-3/vd-17/pd-5"/>
</outConfigs>
Retrieving Storage Controller Security Key
Request:
<configResolveClass cookie="1440536380/580cdbeb-1e29-1e29-8002-1ca31e1b0ff4"
inHierarchical="false" classId="generatedStorageControllerKeyId"/>
Response:
<configResolveClass cookie="1440536380/580cdbeb-1e29-1e29-8002-1ca31e1b0ff4"
response="yes" classId="generatedStorageControllerKeyId">
<outConfigs>
<generatedStorageControllerKeyId
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/gen-key-id"
generatedKeyId="UCSC-MRAID12G_SV44108637_1d6f954e"/>
</outConfigs>
</configResolveClass>
Retrieving Suggested Storage Controller Security Key
Request:
<configResolveClass cookie="1440536380/580cdbeb-1e29-1e29-8002-1ca31e1b0ff4"
inHierarchical="false" classId="suggestedStorageControllerSecurityKey"/>
Response:
<configResolveClass cookie="1440536380/580cdbeb-1e29-1e29-8002-1ca31e1b0ff4" response="yes"
classId="suggestedStorageControllerSecurityKey">
<outConfigs>
<suggestedStorageControllerSecurityKey
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/suggested-sec-key"
suggestedSecurityKey="UPMMOqnwhlGfN@gC6Cs5HqXLUPMMOqnw"/>
</outConfigs>
</configResolveClass>
Retrieving Self-encrypted Storage Controller Details
Request:
<configResolveClass cookie="1440546768/5d6cc751-1e2c-1e2c-8002-a4f07b6138b8"
inHierarchical="false" classId="selfEncryptStorageController"/>
Response:
<configResolveClass cookie="1440546768/5d6cc751-1e2c-1e2c-8002-a4f07b6138b8"
response="yes" classId="selfEncryptStorageController">
<outConfigs>
<selfEncryptStorageController dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt"
keyId="UCSC-MRAID12G_FHH18250010_1cad8d50" securityKey="Security key"
existingSecurityKey="Existing security key" adminAction="no-op" adminSubAction="no-op"/>
</outConfigs>
</configResolveClass>
Enabling Self-encryption on Controllers
Request:
<configConfMo cookie="1443656333/506a0432-2100-1100-8004-6ca2cdf9eca0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt" inHierarchical="false">
<inConfig>
<selfEncryptStorageController adminAction="enable-self-encrypt" keyId="TestKeyId"
securityKey="TestSecurityKey" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt">
</selfEncryptStorageController>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1444870328/8c41b3e1-221a-121a-811c-deabcdf9eca0" response="yes"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA">
<outConfigs>
<storageController id="SLOT-HBA" model="Cisco 12G SAS Modular Raid Controller"
pciSlot="SLOT-HBA" presence="equipped" raidSupport="yes" serial="SV44104119"
type="SAS" vendor="LSI Logic" selfEncryptEnabled="yes"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA"/>
</outConfigs>
</configConfMo>
Disabling Self-encryption on Controllers
Request:
<configConfMo cookie="1444871687/cc606a82-221a-121a-811f-deabcdf9eca0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt" inHierarchical="false">
<inConfig>
<selfEncryptStorageController adminAction="disable-self-encrypt"
existingSecurityKey="TestSecurityKey"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt">
</selfEncryptStorageController>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1444870328/8c41b3e1-221a-121a-811c-deabcdf9eca0"
response="yes" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA">
<outConfigs>
<storageController id="SLOT-HBA" model="Cisco 12G SAS Modular Raid Controller"
pciSlot="SLOT-HBA" presence="equipped" raidSupport="yes" serial="SV44104119"
type="SAS" vendor="LSI Logic" selfEncryptEnabled="No" adminAction="no-op"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA"/>
</outConfigs>
</configConfMo>
Enabling Self-encryption on Physical Drives
Request:
<configConfMo cookie="1444963230/52790541-2230-1230-8195-deabcdf9eca0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-3" inHierarchical="false">
<inConfig>
<storageLocalDisk adminAction="enable-self-encrypt"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-3">
</storageLocalDisk>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1444963230/52790541-2230-1230-8195-deabcdf9eca0"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-3" inHierarchical="false">
<outConfigs>
<storageLocalDisk id="3" pdStatus="JBOD" health="Good" predictiveFailureCount="0"
linkSpeed="6.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB"
vendor="SEAGATE" productId="ST4000NM0063" driveFirmware="0004"
driveSerialNumber="Z1Z8MRC70000R540WM1C" driveState="JBOD" online="true"
dedicatedHotSpareForVDId="" locatorLEDStatus="off" fdeCapable="yes" fdeEnabled="yes"
secured="yes" locked="no" foreignLocked="no" adminAction="no-op"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-3"/>
</outConfigs>
</configConfMo>
Creating Secured Virtual Drive Group
Request:
<configConfMo cookie="1443751990/88100a71-2116-1116-8060-deabcdf9eca0"
inHierarchical="false" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/virtual-drive-create">
<inConfig>
<storageVirtualDriveCreatorUsingUnusedPhysicalDrive adminAction="enable-self-encrypt"
virtualDriveName="1" raidLevel="1" size="600MB" driveGroup="[4,3]" writePolicy="write-through"
adminState="trigger"/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1443751990/88100a71-2116-1116-8060-deabcdf9eca0" inHierarchical="false"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/virtual-drive-create">
<outConfigs>
<storageVirtualDrive id="0" name="1" raidLevel="RAID 1" size="600 MB" vdStatus="Optimal"
health="Good" bootDrive="false" stripSize="64k" drivesPerSpan="2" spanDepth="1"
accessPolicy="read-write" cachePolicy="direct-io" readPolicy="no-read-ahead"
requestedWriteCachePolicy="write-through" currentWriteCachePolicy="write-through"
diskCachePolicy="unchanged" allowBackgroundInit="true" autoSnapshot="false"
autoDeleteOldest="true" driveState="Optimal" fdeCapable="yes" fdeEnabled="yes"
adminAction="no-op" targetId="0"
physicalDrivesList="Physical drives to be used for virtual drive reconstruction.
pd_id1,pd_id2,...pd_idN" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/vd-0"/>
</outConfigs>
</configConfMo>
Unlocking Secure Drives on Controllers
If you want to import secure drives to a controller from other controllers, you must first unlock these secure drive that you want import. The following XML API request helps you to unlock drives:
Request:
<configConfMo cookie="1445440951/5715265f-229f-129f-8004-c6efa42fa074"
inHierarchical="false" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt" >
<inConfig>
<selfEncryptStorageController
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt"
securityKey="t" adminAction="unlock-secured-drives"/>
</inConfig>
</configConfMo>
Response:
Run a configResolveClass with class ID storageLocalDisk and verify that Locked is set to no and fdeCapable, fdeEnabled, Secured and ForeignLocked are yes.
Erasing Data on Secure Unconfigured Good Drives
Request:
<configConfMo cookie="1440644344/0ffb96f5-1e43-1e43-8002-a4f07b6138b8"
inHierarchical="false" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-4">
<inConfig>
<storageLocalDisk adminAction="disable-self-encrypt"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-4">
</storageLocalDisk>
</inConfig>
</configConfMo>
Response:
<outConfig>
<storageLocalDisk id="3" pdStatus="Unconfigured Good" health="Good" predictiveFailureCount="0"
linkSpeed="6.0 Gb/s" interfaceType="SAS" mediaType="HDD" coercedSize="3814697 MB"
vendor="SEAGATE" productId="ST4000NM0063" driveFirmware="0004"
driveSerialNumber="Z1Z8MRC70000R540WM1C" driveState="Unconfigured Good"
online="true" dedicatedHotSpareForVDId="" locatorLEDStatus="off"
fdeCapable="yes" fdeEnabled="yes"secured="yes" locked="no" foreignLocked="no"
adminAction="no-op" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-3"
status="modified" >
</storageLocalDisk>
</outConfig>
Erasing Data on Secure Foreign Drives
Request:
<configConfMo cookie="1440644344/0ffb96f5-1e43-1e43-8002-a4f07b6138b8"
inHierarchical="false" dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-4">
<inConfig>
<storageLocalDisk adminAction="disable-sed-foreign-drives"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-4">
</storageLocalDisk>
</inConfig>
</configConfMo>
Response:
<outConfig>
<storageLocalDisk id="3" pdStatus="Foreign Configuration" health="Moderate Fault"
predictiveFailureCount="0" linkSpeed="6.0 Gb/s" interfaceType="SAS" mediaType="HDD"
coercedSize="3814697 MB" vendor="SEAGATE" productId="ST4000NM0063" driveFirmware="0004"
driveSerialNumber="Z1Z8MRC70000R540WM1C" driveState="Foreign Configuration" online="true"
dedicatedHotSpareForVDId="" locatorLEDStatus="off" fdeCapable="yes" fdeEnabled="yes"
secured="yes" locked="yes" foreignLocked="yes" adminAction="no-op"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/pd-3" status="modified" >
</storageLocalDisk>
</outConfig>
Modifying the Controller Key ID
Request:
<configConfMo cookie ='1450387768/f9532d76-271e-171e-8002-deabcdf9eca0' inHierarchical='false'
dn='sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt'>
<inConfig>
<selfEncryptStorageController adminAction='modify-self-encrypt' keyId='TestKeyChange'
dn='sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt'/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1450387768/f9532d76-271e-171e-8002-deabcdf9eca0" response="yes"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt">
<outConfig>
<selfEncryptStorageController dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt"
keyId="TestKeyChange" securityKey="Security key" existingSecurityKey="Existing security key"
adminAction="no-op" status="modified" >
</selfEncryptStorageController>
</outConfig>
</configConfMo>
Modifying the Controller Security Key
Request:
<configConfMo cookie ='1450387768/f9532d76-271e-171e-8002-deabcdf9eca0' inHierarchical='false'
dn='sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt'>
<inConfig>
<selfEncryptStorageController adminAction='modify-self-encrypt'
securityKey='TestSecurityChange' existingSecurityKey='TestSecurity'
dn='sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt'/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1450387768/f9532d76-271e-171e-8002-deabcdf9eca0" response="yes"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt">
<outConfig>
<selfEncryptStorageController dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt"
keyId="TestKeyChange" securityKey="Security key" existingSecurityKey="Existing security key"
adminAction="no-op" status="modified" >
</selfEncryptStorageController>
</outConfig>
</configConfMo>
Modifying Controller Security Key and the Key ID
Request:
<configConfMo cookie ='1450387768/f9532d76-271e-171e-8002-deabcdf9eca0' inHierarchical='false'
dn='sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt'>
<inConfig>
<selfEncryptStorageController adminAction='modify-self-encrypt' keyId='TestKeyChange'
securityKey='TestSecurityChange' existingSecurityKey='TestSecurity'
dn='sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt'/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1450387768/f9532d76-271e-171e-8002-deabcdf9eca0" response="yes"
dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt">
<outConfig>
<selfEncryptStorageController dn="sys/rack-unit-1/board/storage-SAS-SLOT-HBA/ctr-self-encrypt"
keyId="TestKeyChange" securityKey="Security key" existingSecurityKey="Existing security key"
adminAction="no-op" status="modified" >
</selfEncryptStorageController>
</outConfig>
</configConfMo>
Retrieving Network Time Protocol (NTP) Properties
Request:
<configResolveClass cookie='1357785728/200df7e0-d2e6-12e6-8004-3e02e2a85750'
classId='commNtpProvider' inHierarchical='false'>
Response:
<configResolveClass cookie="1357785728/200df7e0-d2e6-12e6-8004-3e02e2a85750"
response="yes" classId="commNtpProvider">
<outConfigs>
<commNtpProvider dn="sys/svc-ext/ntp-svc" description="Network Time Protocol"
ntpEnable="no" ntpServer1="0. pool.ntp.org" ntpServer2="1.pool.ntp.org"
ntpServer3="2.pool.ntp.org" ntpServer4="3.pool.ntp.org" >
</commNtpProvider>
</outConfigs>
Configuring Network Time Protocol (NTP) Properties
Request:
<configConfMo cookie="1360482215/f33512f0-d559-1559-8007-30339ee53d50"
dn="sys/svc-ext/ntp-svc">
<inConfig>
<commNtpProvider dn="sys/svc-ext/ntp-svc" ntpEnable="yes" ntpServer1="172.29.xxx.187"
ntpServer2="ntpserver.cisco.com" ntpServer3="ntp.globalcomp.net"
ntpServer4="170.xx.198.25"/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1360482215/f33512f0-d559-1559-8007-30339ee53d50"
response="yes" dn="sys/svc-ext/ntp-svc" >
<outConfig>
<commNtpProvider dn="sys/svc-ext/ntp-svc" description="Network Time Protocol"
ntpEnable="yes" ntpServer1="172.xx.xxx.187" ntpServer2="ntpserver.cisco.com"
ntpServer3="ntp.globalcomp.net" ntpServer4="170.xx.198.25"
status="modified"/>
</outConfig>
</configConfMo>
Retrieving all Cisco IMC Users
Request:
<configResolveClass cookie="1360213362/5a499e50-d51b-151b-8008-30339ee53d50"
inHierarchical="false" classId="aaaUser"/>
Response:
<configResolveClass cookie="1360213362/5a499e50-d51b-151b-8008-30339ee53d50"
response="yes" classId="aaaUser">
<outConfigs>
<aaaUser id="1" accountStatus="active" name="admin" priv="admin" pwd="" dn="sys/user-ext/user-1"/>
<aaaUser id="2" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-2"/>
<aaaUser id="3" accountStatus="active" name="server.monitor" priv="read-only" pwd=""
dn="sys/user-ext/user-3"/>
<aaaUser id="4" accountStatus="active" name="acme" priv="user" pwd="" dn="sys/user-ext/user-4"/>
<aaaUser id="5" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-5"/>
<aaaUser id="6" accountStatus="active" name="msgDept" priv="admin" pwd=""
dn="sys/user-ext/user-6"/>
<aaaUser id="7" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-7"/>
<aaaUser id="8" accountStatus="inactive" name="john_srvadmin" priv="admin" pwd=""
dn="sys/user-ext/user-8"/>
<aaaUser id="9" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-9"/>
<aaaUser id="10" accountStatus="inactive" name="qa.manager-dept" priv="read-only" pwd=""
dn="sys/user-ext/user-10"/>
<aaaUser id="11" accountStatus="inactive" name="" priv="" pwd=""
dn="sys/user-ext/user-11"/>
<aaaUser id="12" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-12"/>
<aaaUser id="13" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-13"/>
<aaaUser id="14" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-14"/>
<aaaUser id="15" accountStatus="inactive" name="" priv="" pwd="" dn="sys/user-ext/user-15"/>
</outConfigs>
Setting up ID 11 Cisco IMC User With Username and Password and Enabling Login Access to this User
Request:
<configConfMo cookie="1360213362/5a499e50-d51b-151b-8008-30339ee53d50"
inHierarchical="false" dn="sys/user-ext/user-11">
<inConfig>
<aaaUser id="11" accountStatus="active" name="master.work" priv="admin"
pwd="password" dn="sys/user-ext/user-11"/>
</inConfig>
Response:
<configConfMo cookie="1360213362/5a499e50-d51b-151b-8008-30339ee53d50" response="yes"
dn="sys/user-ext/user-11">
<outConfig>
<aaaUser id="11" accountStatus="active" name="master.work"
priv="admin" pwd="" dn="sys/user-ext/user-11" status="modified"/>
</outConfig>
</configConfMo>
Configuring User ID 3, Deactivating this User and Changing the
Password
Request:
<configConfMo cookie="1360213362/5a499e50-d51b-151b-8008-30339ee53d50"
inHierarchical="false" dn="sys/user-ext/user-3">
<inConfig>
<aaaUser id="3" accountStatus="inactive" name="server.monitor" priv="user"
pwd="Game(hang#" dn="sys/user-ext/user-3"/>
</inConfig>
</configConfMo>
Response:
<configConfMo cookie="1360213362/5a499e50-d51b-151b-8008-30339ee53d50" response="yes"
dn="sys/user-ext/user-3" >
<outConfig>
<aaaUser id="3" accountStatus="inactive" name="server.monitor" priv="user"
pwd="" dn="sys/user-ext/user-3" status="modified"/>
</outConfig>
Disabling or Enabling Strong Password
Enabling Strong Password
Request:
<configConfMo cookie="1438173516/dd4b406b-1c03-1c03-8002-a3209f054ef4"
dn="sys/user-ext/policy" inHierarchical="false">
<inConfig>
<aaaUserPolicy userPasswordPolicy="enabled" dn="sys/user-ext/policy"/>
</inConfig>
</configConfMo>
Disabling Strong Password
Request:
<configConfMo cookie="1438173516/dd4b406b-1c03-1c03-8002-a3209f054ef4"
dn="sys/user-ext/policy" inHierarchical="false">
<inConfig>
<aaaUserPolicy userPasswordPolicy="disabled" dn="sys/user-ext/policy"/>
</inConfig>
</configConfMo>
Retrieving Memory Unit Statistics
Request:
<configResolveClass cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false' classId='memoryUnitEnvStats'>
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="memoryUnitEnvStats">
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58"
response="yes" classId="memoryUnitEnvStats">
<outConfigs>
<memoryUnitEnvStats dn="sys/rack-unit-1/board/memarray-1/mem-9/dimm-env-stats"
id="9" description="CPU1_B0_DIMM_1" temperature="16.0" timeCollected="2013-2-5T19:33:41">
</memoryUnitEnvStats>
<memoryUnitEnvStats dn="sys/rack-unit-1/board/memarray-1/mem-13/dimm-env-stats"
id="13" description="CPU1_B1_DIMM_1" temperature="18.0" timeCollected="2013-2-5T19:33:42">
</memoryUnitEnvStats>
</outConfigs>
</configResolveClass>
Retrieving Specific DIMM Memory Unit Statistics
Request:
<configResolveDn cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false' dn='sys/rack-unit-1/board/memarray-1/mem-45/dimm-env-stats' >
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="memoryUnitEnvStats">
<outConfigs>
<memoryUnitEnvStats dn="sys/rack-unit-1/board/memarray-1/mem-9/dimm-env-stats"
id="9" description="CPU1_B0_DIMM_1" temperature="16.0" timeCollected="2013-2-5T19:33:41"
</memoryUnitEnvStats>
</outConfigs>
</configResolveClass>
Retrieving Processor Environment Statistics
Request:
<configResolveClass cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false' classId='processorEnvStats'>
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="processorEnvStats">
<outConfigs>
<processorEnvStats dn="sys/rack-unit-1/board/cpu-1/env-stats"
id="1" description="P1_TEMP_SENS" temperature="36.0" timeCollected="2013-2-9T19:40:37">
</processorEnvStats>
<processorEnvStats dn="sys/rack-unit-1/board/cpu-2/env-stats"
id="2" description="P2_TEMP_SENS" temperature="35.0" timeCollected="2013-2-9T19:40:37">
</processorEnvStats>
</outConfigs>
</configResolveClass>
Retrieving Specific DIMM Processor Environment Statistics
Request:
<configResolveDn cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false' dn='sys/rack-unit-1/board/cpu-2/env-stats' >
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="processorEnvStats">
<outConfigs>
<processorEnvStats dn="sys/rack-unit-1/board/cpu-1/env-stats"
id="1" description="P1_TEMP_SENS" temperature="36.0" timeCollected="2012-11-29T19:40:37">
</processorEnvStats>
<processorEnvStats dn="sys/rack-unit-1/board/cpu-2/env-stats"
id="2" description="P2_TEMP_SENS" temperature="35.0" timeCollected="2012-11-29T19:40:37">
</processorEnvStats>
</outConfigs>
</configResolveClass>
Retrieving Motherboard Temperature Statistics
Request:
<configResolveClass cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
classId='computeRackUnitMbTempStats' inHierarchical='false'>
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="computeRackUnitMbTempStats">
<outConfigs>
<computeRackUnitMbTempStats dn="sys/rack-unit-1/board/temp-stats" ambientTemp="18.0"
frontTemp="18.0" ioh1Temp="46.0" ioh2Temp="53.0"
rearTemp="32.0" timeCollected="2013-2-9T19:41:29" >
</computeRackUnitMbTempStats>
</outConfigs>
</configResolveClass>
Retrieving Specific DIMM Motherboard Temperature Statistics
Request:
<configResolveDn cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false'dn='sys/rack-unit-1/board/temp-stats' >
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="computeRackUnitMbTempStats">
<outConfigs>
<computeRackUnitMbTempStats dn="sys/rack-unit-1/board/temp-stats"
ambientTemp="18.0" frontTemp="18.0" ioh1Temp="46.0" ioh2Temp="53.0" rearTemp="32.0"
timeCollected="2013-2-9T19:41:29" >
</computeRackUnitMbTempStats>
</outConfigs>
</configResolveClass>
Retrieving Motherboard Power Statistics
Request:
<configResolveClass cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
classId='computeMbPowerStats' inHierarchical='false'>
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="computeMbPowerStats">
<outConfigs>
<computeMbPowerStats dn="sys/rack-unit-1/board/power-stats"
consumedPower="280" inputCurrent="" inputVoltage="" timeCollected="2012-11-29T19:49:49" >
</computeMbPowerStats>
</outConfigs>
</configResolveClass>
Retrieving Specific DIMM Motherboard Power Statistics
Request:
<configResolveDn cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false'dn='sys/rack-unit-1/board/power-stats'>
Response:
<configResolveClass cookie="1354217286/484b4498-cfa7-1fa7-8002-aab825098d58" response="yes"
classId="computeMbPowerStats">
<outConfigs>
<computeMbPowerStats dn="sys/rack-unit-1/board/power-stats"
consumedPower="280" inputCurrent="" inputVoltage="" timeCollected="2013-2-9T19:49:49">
</computeMbPowerStats>
</outConfigs>
</configResolveClass>
Retrieving iSCSI Parameters
Request:
<configResolveDn cookie='1350453563/f8f69e20-cc3a-1c3a-8003-6cdd29114ca4'
inHierarchical='false' dn='sys/rack-unit-1/adaptor-1/host-eth-adad/ethiscsi'>
Response:
<configResolveClass cookie="1350515994/821a1d18-cc49-1c49-8007-6cdd29114ca4" response="yes"
classId="adaptorEthISCSIProfile">
<outConfigs>
<adaptorEthISCSIProfile dn="sys/rack-unit-1/adaptor-2/host-eth-eth0/ethiscsi"
linkupTimeout="15" linkBusyRetryCount="15" ipVer="IPv4" dhcpId="" dhcpTimeout="60"
dhcpNetworkSettings="enabled" dhcpISCSI="enabled" initiatorName="test" initiatorTCPTimeout="15"
primaryTargetName="test.com" primaryTargetIPAddress="192.xxx.1.1" primaryTargetPort="3260"
primaryTargetBootLun="0">
</adaptorEthISCSIProfile>
</outConfigs>
</configResolveClass>
Removing iSCSI Boot
Request:
<configConfMo cookie='1350517826/ef4dd140-cc49-1c49-8008-6cdd29114ca4'
inHierarchical='false' dn='sys/rack-unit-1/adaptor-2/host-eth-eth1/ethiscsi' >
<inConfig>
<adaptorEthISCSIProfile linkupTimeout='85' linkBusyRetryCount='135' dhcpId='vendrocisco'
dhcpTimeout='88' dhcpNetworkSettings='enabled' dhcpISCSI='enabled' status='removed'
dn='sys/rack-unit-1/adaptor-2/host-eth-eth1/ethiscsi'>
</adaptorEthISCSIProfile>
</inConfig>
</configConfMo>
Response: Verify that the iSCSI boot is disabled in the web user interface or CLI.
<configConfMo cookie="1350517826/ef4dd140-cc49-1c49-8008-6cdd29114ca4" "response="yes"
dn="sys/rack-unit-1/adaptor-2/host-eth-eth1/ethiscsi">
<outConfig>
</outConfig>
</configConfMo>
Retrieving Fault Objects Identified by Cisco IMC
Request:
<configResolveClass cookie="1360461607/26daf980-d555-1555-8004-0834b6fdd0d0"
inHierarchical="false" classId="faultInst">
Response:
<configResolveClass cookie="1360461607/26daf980-d555-1555-8004-0834b6fdd0d0" response="yes"
classId="faultInst">
<outConfigs>
<faultInst ack="yes" cause="powerproblem" code="F0883"
created="Sat Feb 9 00:30:40 2013"
descr="Power supply 4 is in a degraded state, or has bad input voltage"
affectedDN="sys/rack-unit-1/psu-4" highestSeverity="critical" id="167773192"
lastTransition="Sat Feb 9 00:24:08 2013" lc="flapping" occur="16" origSeverity="cleared"
prevSeverity="cleared" rule="fltEquipmentPsuInputError" severity="critical"
tags="server" type="server" dn="sys/rack-unit-1/fault-F0883"/>
<faultInst ack="yes" cause="psuRedundancyFail" code="F0743"
created="Sat Feb 9 00:30:40 2013"
descr="Power Supply redundancy is lost : Reseat or replace Power Supply "
affectedDN="sys/rack-unit-1/psu" highestSeverity="critical" id="352321544"
lastTransition="Sat Feb 9 00:24:08 2013" lc="flapping" occur="16" origSeverity="cleared"
prevSeverity="cleared" rule="fltPowerChassisMemberChassisPsuRedundanceFailure"
severity="major" tags="server" type="server" dn="sys/rack-unit-1/fault-F0743"/>
<faultInst ack="yes" cause="equipmentDegraded" code="F0969"
created="Fri Feb 8 23:57:44 2013" descr="Storage Raid Battery 11 Degraded:
please check the battery or the storage controller"
affectedDN="sys/rack-unit-1/board/storage-SAS-SLOT-SAS/raid-battery-11"
highestSeverity="critical" id="3539995392" lastTransition="Fri Feb 8 23:11:08 2013"
lc="flapping" occur="2" origSeverity="cleared" prevSeverity="cleared"
rule="fltStorageRaidBatteryDegraded" severity="major" tags="storage" type="server"
dn="sys/rack-unit-1/fault-F0969"/>
<faultInst ack="yes" cause="equipmentInoperable" code="F0531"
created="Fri Feb 8 23:57:44 2013"
descr="Storage Raid Battery 11 is inoperable: Check Controller battery"
affectedDN="sys/rack-unit-1/board/storage-SAS-SLOT-SAS/raid-battery-11"
highestSeverity="critical" id="3539995392" lastTransition="Fri Feb 8 23:11:08 2013"
lc="flapping" occur="2" origSeverity="cleared" prevSeverity="cleared"
rule="fltStorageRaidBatteryInoperable" severity="major" tags="storage"
type="server" dn="sys/rack-unit-1/fault-F0531"/>
</outConfigs>
</configResolveClass>
Generating Temporary Authentication Tokens and Launching the KVM
Launching the KVM console using the XML APIs include the following:
-
Retrieving a session cookie.
-
Generating temporary authentication tokens.
-
Accessing the URL to download the JNLP file using the tokens.
-
Launching the KVM.
Request for obtaining authentication tokens:
<aaaGetComputeAuthTokens cookie="1363034734/412ce290-d7ac-17ac-8006-c979e5e53d50" />'
Response for obtaining authentication tokens:
<aaaGetComputeAuthTokens cookie="1363034734/412ce290-d7ac-17ac-8006-c979e5e53d50"
outTokens="1957747793,424238335" response="yes">
</aaaGetComputeAuthTokens>
To access the URL, use the tokens in the tkn1 and tkn2 parts of the following URL within 60 seconds of generation:
javaws http://<Cisco IMC IP address>/kvm.jnlp?cimcAddr=<Cisco IMC IP address>&tkn1=1957747793&tkn2=424238335
Download the JNLP file from the URL and launch it to start a KVM session.
Retrieving usNIC Device Parameters
Request:
<configResolveClass cookie='1301262014/6a0d66ca-3b1a-49e1-b5d4-334749717158'
classId='adaptorEthUSNICProfile' inHierarchical='true'>
Response:
<configResolveClass cookie="1369708188/0a09aa88-ddbe-1dbe-8003-1fc9e1a85750"
response="yes" classId="adaptorEthUSNICProfile">
<outConfigs>
<adaptorEthUSNICProfile dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
usnicCount="1" transmitQueueCount="2" transmitQueueRingSize="256"
receiveQueueCount="2" receiveQueueRingSize="512"
completionQueueCount="4" interruptCount="4" coalescingType="MIN"
coalescingTime="125" classOfService="0" tcpSegment="disabled"
largeReceive="disabled" tcpTxChecksum="disabled"
tcpRxChecksum="disabled" >
</adaptorEthUSNICProfile>
</outConfigs>
</configResolveClass>
Creating Ethernet Interface usNIC Profiles
Request:
<configConfMo cookie="1364563172/1f244b38-d910-1910-8002-02249ee53d50"
dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic">
<inConfig>
<adaptorEthUSNICProfile dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
usnicCount="3"/>
</inConfig>
</configConfMo>"
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
cookie="1364563172/1f244b38-d910-1910-8002-02249ee53d50" response="yes">
<outConfig>
<adaptorEthUSNICProfile dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
usnicCount="3" transmitQueueCount="2" transmitQueueRingSize="256"
receiveQueueCount="2" receiveQueueRingSize="512" completionQueueCount="4"
interruptCount="4" coalescingType="MIN" coalescingTime="125"
classOfService="0" tcpSegment="disabled" largeReceive="disabled"
tcpTxChecksum="disabled" tcpRxChecksum="disabled" status="modified">
</adaptorEthUSNICProfile>
</outConfig>
</configConfMo>
Modifying Ethernet Interface usNIC Profiles
Request:
<configConfMo cookie="1364563172/1f244b38-d910-1910-8002-02249ee53d50"
dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic">
<inConfig>
<adaptorEthUSNICProfile dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
transmitQueueCount="9"
transmitQueueRingSize="3024" receiveQueueCount="11" receiveQueueRingSize="4024"
completionQueueCount="12"
interruptCount="13" coalescingType="IDLE" coalescingTime="1400" classOfService="5"
tcpSegment="enabled"
largeReceive="enabled" tcpTxChecksum="enabled" tcpRxChecksum="enabled"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
cookie="1364563172/1f244b38-d910-1910-8002-02249ee53d50" response="yes">
<outConfig>
<adaptorEthUSNICProfile dn="sys/rack-unit-1/adaptor-1/host-eth-eth0/ethusnic"
usnicCount="3" transmitQueueCount="9" transmitQueueRingSize="3024"
receiveQueueCount="11" receiveQueueRingSize="4024"
completionQueueCount="12" interruptCount="13" coalescingType="IDLE"
coalescingTime="1400" classOfService="5"
tcpSegment="enabled" largeReceive="enabled" tcpTxChecksum="enabled"
tcpRxChecksum="enabled" status="modified"/>
</outConfig>
</configConfMo>
Retrieving LDAP Server Details
Request:
<configResolveClass cookie="1370404868/3f5f79b8-de60-1e60-8002-1ec9e1a85750"
response="yes" classId="aaaLdap">
Response:
<outConfigs>
<aaaLdap dn="sys/ldap-ext" adminState="enabled" basedn="1.2.3.4"
domain="tfb.com" filter="sAMAccountName" attribute="CiscoAvPair"
timeout="1800" encryption="disabled" locateDirectoryUsingDNS="yes"
dnsDomainSource="extracted-domain" dnsSearchDomain="" dnsSearchForest=""
ldapServer1="172.26.53.36" ldapServerPort1="636"
ldapServer2="0.0.0.0" ldapServerPort2="636"
ldapServer3="ServThree.com" ldapServerPort3="9636"
ldapServer4="myfinance.com" ldapServerPort4="3269"
ldapServer5="199.22.44.253" ldapServerPort5="9269"
ldapServer6="" ldapServerPort6="3269"
bindMethod="login-credentials" bindDn="someDn" password=""
groupAuth="enabled" groupAttribute="memberOf">
<aaaLdapRoleGroup id="1" name="" domain="" role="admin" rn="rolegroup-1" >
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="2" name="" domain="" role="user" rn="rolegroup-2" >
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="3" name="" domain="" role="read-only" rn="rolegroup-3">
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="4" name="" domain="" role="" rn="rolegroup-4" >
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="5" name="" domain="" role="" rn="rolegroup-5" >
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="6" name="" domain="" role="" rn="rolegroup-6" >
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="7" name="" domain="" role="" rn="rolegroup-7" >
</aaaLdapRoleGroup>
<aaaLdapRoleGroup id="8" name="" domain="" role="" rn="rolegroup-8" >
</aaaLdapRoleGroup>
</aaaLdap>
</outConfigs>
Configuring LDAP Server IP Address and Port Numbers
Request:
<configConfMo cookie="1351062607/c6c74fd8-ccc8-1cc8-8005-1ec9e1a85750"
inHierarchical="true" dn="sys/ldap-ext">
<inConfig>
<aaaLdap dn="sys/ldap-ext" adminState="disabled" basedn="" domain="tfb.com"
filter="sAMAccountName" attribute="CiscoAvPair" timeout="60"
encryption="disabled" locateDirectoryUsingDNS="yes"
dnsDomainSource="extracted-domain"
ldapServer1="172.26.53.36" ldapServerPort1="636"
ldapServer2="0.0.0.0" ldapServerPort2="636"
ldapServer3="ServThree.com" ldapServerPort3="9636"
ldapServer4="myfinance.com" ldapServerPort4="3269"
ldapServer5="199.22.44.253" ldapServerPort5="9269"
ldapServer6="" ldapServerPort6="3269"
bindMethod="login-credentials" bindDn="" password=""
groupAuth=disabled" groupAttribute="memberOf">
</inConfig>
Response:
<outConfigs>
<aaaLdap dn="sys/ldap-ext" adminState="disabled" basedn="" domain="tfb.com"
filter="sAMAccountName" attribute="CiscoAvPair" timeout="60"
encryption="disabled" locateDirectoryUsingDNS="yes"
dnsDomainSource="extracted-domain"
ldapServer1="172.26.53.36" ldapServerPort1="636"
ldapServer2="0.0.0.0" ldapServerPort2="636"
ldapServer3="ServThree.com" ldapServerPort3="9636"
ldapServer4="myfinance.com" ldapServerPort4="3269"
ldapServer5="199.22.44.253" ldapServerPort5="9269"
ldapServer6="" ldapServerPort6="3269"
bindMethod="login-credentials" bindDn="someDn" password=""
groupAuth="disabled" groupAttribute="memberOf" status="modified">
<aaaLdapRoleGroup id="1" name="" domain="" role="admin" rn="rolegroup-1" >
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="2" name="" domain="" role="user" rn="rolegroup-2" >
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="3" name="" domain="" role="read-only" rn="rolegroup-3">
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="4" name="" domain="" role="" rn="rolegroup-4" >
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="5" name="" domain="" role="" rn="rolegroup-5" >
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="6" name="" domain="" role="" rn="rolegroup-6" >
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="7" name="" domain="" role="" rn="rolegroup-7" >
status="modified" </aaaLdapRoleGroup>
<aaaLdapRoleGroup id="8" name="" domain="" role="" rn="rolegroup-8" >
status="modified" </aaaLdapRoleGroup>
</aaaLdap>
</outConfigs>
Configuring LDAP Parameters
You can configure LDAP parameters such as, LDAP status, encryption, timeout, domain, base Dn, binding parameters, DNS parameters, group authorization parameters, LDAP role groups and so on. The following example shows configuring LDAP parameters:
Request:
<configConfMo cookie="1351062607/c6c74fd8-ccc8-1cc8-8005-1ec9e1a85750"
inHierarchical="true" dn="sys/ldap-ext">
<inConfig>
<aaaLdap dn="sys/ldap-ext" adminState="enabled" basedn="ExampleDn"
domain="Example.com" filter="MysAMAccountNameYes" attribute="CiscoAviator"
timeout="160" encryption="enabled" locateDirectoryUsingDNS="no"
dnsDomainSource="extracted-domain" dnsSearchDomain="child.cp.com"
dnsSearchForest="cp.com"
ldapServer1="172.26.53.36" ldapServerPort1="636"
ldapServer2="0.0.0.0" ldapServerPort2="636"
ldapServer3="ServThree.com" ldapServerPort3="9636"
ldapServer4="myfinance.com" ldapServerPort4="3269"
ldapServer5="199.22.44.253" ldapServerPort5="9269"
ldapServer6="" ldapServerPort6="3269"
bindMethod="anonymous" bindDn="myexampleDn"
password="magic@#$%(!#&$" groupAuth=enabled"
groupAttribute="memberOfExample">
<aaaLdapRoleGroup id="1" name="name1"
domain="name1.cisco.com" role="user" rn="rolegroup-1"/>
<aaaLdapRoleGroup id="2" name="" domain="" role="read-only"
rn="rolegroup-2"/>
<aaaLdapRoleGroup id="3" name="" domain="" role="admin"
rn="rolegroup-3"/>
<aaaLdapRoleGroup id="4" name="name2"
domain="sjssjsj.djdjdjd.cook.com" role="user" rn="rolegroup-4"/>
<aaaLdapRoleGroup id="5" name="" domain="" role="" rn="rolegroup-5"/>
<aaaLdapRoleGroup id="6" name="" domain="" role="" rn="rolegroup-6"/>
<aaaLdapRoleGroup id="7" name="" domain="domainname.com"
role="admin" rn="rolegroup-7"/>
<aaaLdapRoleGroup id="8" name="" domain="" role="" rn="rolegroup-8"/>
<aaaLdapRoleGroup id="9" name="" domain="" role="" rn="rolegroup-9"/>
<aaaLdapRoleGroup id="10" name="name3"
domain="dorm.ucs.com" role="read-only" rn="rolegroup-10"/>
</aaaLdap>
</inConfig>
</configMo>"
Response:
<configConfMo cookie="1370760204/fb173e00-deb2-1eb2-8002-1ec9e1a85750"
response="yes" dn="sys/ldap-ext" >
<outConfig>
<aaaLdap dn="sys/ldap-ext" adminState="enabled" basedn="ExampleDn"
domain="Example.com" filter="MysAMAccountNameYes" attribute="CiscoAviator"
timeout="160" encryption="enabled" locateDirectoryUsingDNS="yes"
dnsDomainSource="configured-domain" dnsSearchDomain="child.cp.com"
dnsSearchForest="cp.com"
ldapServer1="172.26.53.36" ldapServerPort1="636"
ldapServer2="0.0.0.0" ldapServerPort2="636"
ldapServer3="ServThree.com" ldapServerPort3="9636"
ldapServer4="myfinance.com" ldapServerPort4="3269"
ldapServer5="199.22.44.253" ldapServerPort5="9269"
ldapServer6="" ldapServerPort6="3269"
bindMethod="anonymous" bindDn="myexampleDn" password=""
groupAuth="enabled" groupAttribute="memberOfExample"
status="modified">
<aaaLdapRoleGroup id="1" name="name1"
domain="name1.cisco.com" role="user" rn="rolegroup-1"
status="modified" />
<aaaLdapRoleGroup id="2" name="" domain="" role="read-only"
rn="rolegroup-2" anonymous status="modified"/>
<aaaLdapRoleGroup id="3" name="" domain="" role="admin"
rn="rolegroup-3" status="modified"/>
<aaaLdapRoleGroup id="4" name="name2"
domain="sjssjsj.djdjdjd.cook.com" role="user"
rn="rolegroup-4" status="modified"/>
<aaaLdapRoleGroup id="5" name="" domain="" role="" rn="rolegroup-5"
status="modified"/>
<aaaLdapRoleGroup id="6" name="" domain="" role="" rn="rolegroup-6"
status="modified"/>
<aaaLdapRoleGroup id="7" name="" domain="domainname.com"
role="admin" rn="rolegroup-7" status="modified"/>
<aaaLdapRoleGroup id="8" name="" domain="" role="" rn="rolegroup-8"
status="modified"/>
<aaaLdapRoleGroup id="9" name="" domain="" role="" rn="rolegroup-9"
status="modified"/>
<aaaLdapRoleGroup id="10" name="name3"
domain="dorm.ucs.com" role="read-only"
rn="rolegroup-10" status="modified"/>
</aaaLdap>
</inConfig>
</configMo>"
Querying to Check Cisco IMC for NI-IOD Support
Request
<configResolveClass cookie="1375699222/ef7afa00-e330-1330-8004-22bcaa4c93a4"
inHierarchical="false" classId="iodController"/>
Response
<configResolveClass cookie="1375699222/ef7afa00-e330-1330-8004-22bcaa4c93a4"
response="yes" classId="iodController">
<outConfigs>
<iodController dn="sys/iod"
description="Non-Interactive Offline Diagnostics (IOD)"/>
</outConfigs>
</configResolveClass>
Triggering Snapshot based on Parameters Provided with Request
Request
<configConfMo cookie="1375699222/ef7afa00-e330-1330-8004-22bcaa4c93a4"
inHierarchical="true" dn="sys/iod/snapshotStart">
<inConfig>
<iodSnapshotStart dn="sys/iod/snapshotStart"
adminState="trigger" isoShareIp="10.10.10.10"
isoShare="/home/sriparim/xfer/ucs-cxx-scu-3.1.2.iso"
isoShareType="nfs" username="none" password="none" timeOut="30"
remoteShareIp="10.10.10.10" remoteSharePath="/home/sriparim/xfer"
remoteShareFile="" remoteShareType="scp" remoteShareUsername="root"
remoteSharePassword="topspin123" />
</inConfig>
</configConfMo>
Response
<configConfMo cookie="1375699222/ef7afa00-e330-1330-8004-22bcaa4c93a4"
dn="sys/iod/snapshotStart">
<outConfig>
<iodSnapshotStart dn="sys/iod/snapshotStart" adminState="triggered"
isoShareIp="10.10.10.10" isoSharePath="/home/sriparim/xfer"
isoShareFile="ucs-cxx-scu-3.1.2.iso" isoShareType="nfs"
username="none" password="" remoteShareIp="10.10.10.10"
remoteSharePath="/home/sriparim/xfer" remoteShareFile=""
remoteShareType="scp" remoteShareUsername="root" remoteSharePassword=""
timeOut="30" status="modified" />
</outConfig>
</configConfMo>
Querying Status of Current or Previous Snapshot Operation
Request
<configResolveClass inHierarchical="false"
cookie="1375695710/1e1ff5c8-e330-1330-8002-22bcaa4c93a4"
classId="iodSnapshotStatus"/>
Response: Host Booting
<configResolveClass cookie="1375695710/1e1ff5c8-e330-1330-
8002-22bcaa4c93a4" response="yes" classId="iodSnapshotStatus">
<outConfigs>
<iodSnapshotStatus dn="sys/iod/snapshotStatus" currentStatus=
"SCU (NI-IOD) booting in progress" currentTime="Mon Aug 5 09:46:00 2013 "
startTime="Mon Aug 5 09:46:00 2013 " runningTime="NA"
snapshotReport="yes" remoteShareIp="NA"
remoteSharePath="NA" remoteShareFile="NA" />
</outConfigs>
</configResolveClass>
Response: IOD Tests in Progress
<configResolveClass cookie="1375699222/ef7afa00-e330
-1330-8004-22bcaa4c93a4" response="yes" classId="iodSnapshotStatus">
<outConfigs>
<iodSnapshotStatus dn="sys/iod/snapshotStatus"
currentStatus="SCU Non-interactive IOD tests is in progress"
currentTime="Mon Aug 5 10:48:54 2013
"startTime="Mon Aug 5 10:40:29 2013" runningTime="
0 Hours 8 Minutes 49 Seconds" snapshotReport="yes" remoteShareIp="NA"
remoteSharePath="NA"remoteShareFile="NA" />
</outConfigs>
</configResolveClass>
Response: IOD Tests Completed
<configResolveClass cookie="1375699222/ef7afa00-e330-1330
-8004-22bcaa4c93a4" response="yes" classId="iodSnapshotStatus">
<outConfigs>
<iodSnapshotStatus dn="sys/iod/snapshotStatus" currentStatus="
Snapshot completed on this CIMC" currentTime="Mon Aug 5 11:11:24 2013"
startTime="Mon Aug 5 10:40:29 2013 " runningTime="
0 Hours 31 Minutes 0 Seconds" snapshotReport="yes"
remoteShareIp="10.10.10.10" remoteSharePath="/home/sriparim/xfer"
remoteShareFile="" />
</outConfigs>
</configResolveClass>
Response: No Session in Progress
<configResolveClass cookie="1375710321/850e6910-e333-1333
-8006-22bcaa4c93a4" response="yes" classId="iodSnapshotStatus">
<outConfigs>
<iodSnapshotStatus dn="sys/iod/snapshotStatus"
currentStatus="NI-IOD session not found" currentTime="Sat Jan 3 00:26:05 1970"
startTime="NA" runningTime="NA" snapshotReport="no" remoteShareIp="NA"
remoteSharePath="NA" remoteShareFile="NA" />
</outConfigs>
</configResolveClass>
Retrieving the Existing Fault Events on a Server
Request:
<configResolveClass cookie='1307953743/b63ff130-a593-1593-8004-2e4ac2e14388'
classId='faultInst' inHierarchical='true'>
Response:
<configResolveClass cookie="1373297279/b08308c8-e101-1101
-8007-5afca0114ca4" response="yes" classId="faultInst">
<outConfigs>
<faultInst ack="yes" cause="equipmentDegraded" code="F1008"
created="Sun Jun 30 18:51:36 2013" descr="Storage Virtual Drive 0
Degraded: please check the storage controller, or reseat the storage drive"
affectedDN="sys/rack-unit-1/board/storage-SAS-SLOT-4/vd-0"
highestSeverity="critical" id="3523280896" lastTransition="" lc="flapping"
occur="1" origSeverity="cleared" prevSeverity="cleared"
rule="fltStorageVirtualDriveDegraded" severity="warning" tags="storage"
type="server" dn="sys/rack-unit-1/fault-F1008" >
</faultInst>
</outConfigs>
</configResolveClass>
Retrieving Object and Fault Details of an affectedDn
This retrieves the details of the object and the associated faults.
Request:
<configResolveDn cookie="1374520602/84383130-e21e-121e-8003-5afca0114ca4"
response="yes" dn="sys/rack-unit-1/board/storage-SAS-SLOT-4/pd-16">
Response:
<outConfig>
<storageLocalDisk id="16" pdStatus="Rebuilding" health="Moderate Fault"
predictiveFailureCount="0" linkSpeed="6.0 Gb/s" interfaceType="SATA"
mediaType="HDD" coercedSize="476416 MB" vendor="ATA" productId="ST9500620NS"
driveFirmware="CC02" driveSerialNumber="9XF14F21" driveState="rebuild"
online="false" dn="sys/rack-unit-1/board/storage-SAS-SLOT-4/pd-16" >
<storageLocalDiskProps rn="general-props" physicalDrive="16"
enclosureDeviceId="8" deviceId="12" sequenceNumber="4" mediaErrorCount="0"
otherErrorCount="0" predictiveFailureCount="0" linkSpeed="6.0 Gb/s"
interfaceType="SATA" mediaType="HDD" blockSize="512" blockCount="976773168"
rawSize="476940 MB" nonCoercedSize="476428 MB" coercedSize="476416 MB"
powerState="active" sasAddress0="a44c11a0fc5a009f" sasAddress1="0x0" >
</storageLocalDiskProps>
<faultInst ack="yes" cause="equipment-inoperable" code="F0181"
created="Mon Jul 22 18:48:14 2013" descr="Storage Local disk 16 is inoperable:
reseat or replace the storage drive 16"
affectedDN="sys/rack-unit-1/board/storage-SAS-SLOT-4/pd-16"
highestSeverity="critical" id="3506704384" lastTransition=""
lc="flapping" occur="1" origSeverity="0" prevSeverity="0"
rule="fltStorageLocalDiskInoperable" severity="3" tags="2" type="server"
rn="fault-F0181" >
</faultInst>
</storageLocalDisk>
</outConfig>
</configResolveDn>
Retrieving Fault Details of a Fault Dn
Request:
<configResolveDn cookie="1374520602/84383130-e21e-121e-8003-5afca0114ca4"
dn="sys/rack-unit-1/fan-module-1-1/fan-1/fault-F0395">
Response:
<configResolveDn cookie="1388395900/1c7baee0-eebd-1ebd-808c-1fc9e1a85750"
response="yes" dn="sys/rack-unit-1/fan-module-1-1/fan-1/fault-F0395">
<outConfig>
<faultInst ack="yes" cause="performance-problem" code="F0395"
created="Mon Dec 30 09:35:19 2013" descr="FAN1_TACH1:
Fan speed for fan-1 is lower non critical:Check the air intake to the server"
affectedDN="sys/rack-unit-1/fan-module-1-1/fan-1"
highestSeverity="critical" id="486539524" lastTransition="" lc="flapping"
occur="1" origSeverity="cleared" prevSeverity="cleared"
rule="fltEquipmentFanPerfThresholdNonCritical" severity="minor"
tags="server" type="server"
dn="sys/rack-unit-1/fan-module-1-1/fan-1/fault-F0395" >
</faultInst>
</outConfig>
</configResolveDn>
Configuring BIOS Parameters Across Various Platforms Using a Master XML Request
Using the XML API interface, you can use the master BIOS parameters configuration XML request to configure BIOS parameters across different C-series servers. The BIOS parameters in this master XML request that are not supported on a specific platform are ignored. The supported parameters are configured as specified in the XML request.
Request:
<configConfMo dn="sys/rack-unit-1/bios/bios-settings"
inHierarchical="true" cookie="1379605932/898925a0-e6be-16be-922b-5bfca0114ca4">
<inConfig>
<biosSettings>
<biosVfAdjacentCacheLinePrefetch dn="sys/rack-unit-1
/bios/bios-settings/ Adjacent-Cache-Line-Prefetch"
vpAdjacentCacheLinePrefetch="enabled"/>
<biosVfAltitude dn="sys/rack-unit-1/bios/bios-settings
/Altitude-Param" vpAltitude="900-m"/>
<biosVfASPMSupport dn="sys/rack-unit-1/bios/bios-settings
/ASPM-Support" vpASPMSupport="Disabled"/>
<biosVfAssertNMIOnPERR dn="sys/rack-unit-1/bios/bios-settings
/Assert-NMI-on-PERR" vpAssertNMIOnPERR="enabled"/>
<biosVfAssertNMIOnSERR dn="sys/rack-unit-1/bios/bios-settings
/Assert-NMI-on-SERR" vpAssertNMIOnSERR="enabled"/>
<biosVfBootOptionRetry dn="sys/rack-unit-1/bios/bios-settings
/Boot-option-retry" vpBootOptionRetry="disabled"/>
<biosVfCkeLowPolicy dn="sys/rack-unit-1/bios/bios-settings
/Cke-Low-Policy" vpCkeLowPolicy="auto"/>
<biosVfConsoleRedirection dn="sys/rack-unit-1/bios/bios-settings
/Console-redirection" vpLegacyOSRedirection="disabled"
vpRedirectionAfterPOST="Always Enable" vpPuttyKeyPad="ESCN"
vpTerminalType="vt100-plus" vpFlowControl="none"
vpConsoleRedirection="enabled" vpBaudRate="115200"/>
<biosVfCoreMultiProcessing dn="sys/rack-unit-1/bios/bios-settings
/Core-MultiProcessing" vpCoreMultiProcessing="all"/>
<biosVfCPUEnergyPerformance dn="sys/rack-unit-1/bios/bios-settings
/CPU-EngPerfBias"vpCPUEnergyPerformance="balanced-performance"/>
<biosVfCPUFrequencyFloor dn="sys/rack-unit-1/bios/bios-settings
/CPU-FreqFloor" vpCPUFrequencyFloor="disabled"/>
<biosVfCPUPerformance dn="sys/rack-unit-1/bios/bios-settings
/CPU-Performance" vpCPUPerformance="enterprise"/>
<biosVfCPUPowerManagement dn="sys/rack-unit-1/bios/bios-settings
/CPU-PowerManagement" vpCPUPowerManagement="energy-efficient"/>
<biosVfDCUPrefetch dn="sys/rack-unit-1/bios/bios-settings
/DCU-Prefetch" vpIPPrefetch="enabled"
vpStreamerPrefetch="enabled"/>
<biosVfDemandScrub dn="sys/rack-unit-1/bios/bios-settings
/Demand-Scrub-Param"
vpDemandScrub="enabled"/>
<biosVfDirectCacheAccess dn="sys/rack-unit-1/bios/bios-settings
/Direct-Cache-Access" vpDirectCacheAccess="enabled"/>
<biosVfDRAMClockThrottling dn="sys/rack-unit-1/bios/bios-settings
/DRAM-Clock-Throttling" vpDRAMClockThrottling="Balanced"/>
<biosVfDramRefreshRate dn="sys/rack-unit-1/bios/bios-settings
/dram-refresh-rate" vpDramRefreshRate="Auto"/>
<biosVfEnhancedIntelSpeedStepTech dn="sys/rack-unit-1/bios
/bios-settings/Enhanced-Intel-SpeedStep-Tech"
vpEnhancedIntelSpeedStepTech="enabled"/>
<biosVfExecuteDisableBit dn="sys/rack-unit-1/bios/bios-settings
/Execute-Disable-Bit" vpExecuteDisableBit="enabled"/>
<biosVfFRB2Enable dn="sys/rack-unit-1/bios/bios-settings
/FRB2-Enable" vpFRB2Enable="enabled"/>
<biosVfHardwarePrefetch dn="sys/rack-unit-1/bios/bios-settings
/Hardware-Prefetch" vpHardwarePrefetch="enabled"/>
<biosVfIntelHyperThreadingTech dn="sys/rack-unit-1/bios
/bios-settings/Intel-HyperThreading-Tech"
vpIntelHyperThreadingTech="enabled"/>
<biosVfIntelTurboBoostTech dn="sys/rack-unit-1/bios/bios-settings
/Intel-Turbo-Boost-Tech" vpIntelTurboBoostTech="enabled"/>
<biosVfIntelVirtualizationTechnology dn="sys/rack-unit-1
/bios/bios-settings/Intel-Virtualization-Technology"
vpIntelVirtualizationTechnology="enabled"/>
<biosVfIntelVTForDirectedIO dn="sys/rack-unit-1/bios/bios-settings
/Intel-VT-for-directed-IO" vpIntelVTForDirectedIO="enabled"
vpIntelVTDPassThroughDMASupport="enabled"
vpIntelVTDInterruptRemapping="enabled"
vpIntelVTDCoherencySupport="disabled"
vpIntelVTDATSSupport="enabled"/>
<biosVfIOHResource dn="sys/rack-unit-1/bios/bios-settings
/ioh-resource" vpIOHResource="IOH0 40k IOH1 24k"/>
<biosVfLegacyUSBSupport dn="sys/rack-unit-1/bios
/bios-settings /LegacyUSB-Support" vpLegacyUSBSupport="enabled"/>
<biosVfLOMPortOptionROM dn="sys/rack-unit-1/bios/bios-settings
/LOMPort-OptionROM" vpLOMPort3State="Enabled"
vpLOMPort2State="Enabled" vpLOMPort1State="Enabled"
vpLOMPort0State="Enabled" vpLOMPortsAllState="Enabled"/>
<biosVfLvDIMMSupport dn="sys/rack-unit-1/bios/bios-settings
/LvDIMM-Support" vpLvDDRMode="power-saving-mode"/>
<biosVfMemoryInterleave dn="sys/rack-unit-1/bios/bios-settings
/Memory-Interleave" vpRankInterLeave="auto"
vpChannelInterLeave="auto"/>
<biosVfMemoryMappedIOAbove4GB dn="sys/rack-unit-1/bios/bios-settings/
Memory-mapped-IO-above-4GB" vpMemoryMappedIOAbove4GB="enabled"/>
<biosVfMirroringMode dn="sys/rack-unit-1/bios/bios-settings
/Mirroring-Mode" vpMirroringMode="intra-socket"/>
<biosVfNUMAOptimized dn="sys/rack-unit-1/bios/bios-settings
/NUMA-optimized" vpNUMAOptimized="enabled"/>
<biosVfOnboardNIC dn="sys/rack-unit-1/bios/
bios-settings/Onboard-NIC" vpOnboard10GbitLOM="enabled"
vpOnboardGbitLOM="enabled"/>
<biosVfOnboardStorage dn="sys/rack-unit-1/bios/bios-settings
/Onboard-Storage" vpOnboardSCUStorageSupport="disabled"/>
<biosVfOnboardStorageSWStack dn="sys/rack-unit-1/bios
/bios-settings/ Onboard-SCU-Storage-SWStack"
vpOnboardSCUStorageSWStack="LSI SW RAID"/>
<biosVfOSBootWatchdogTimer dn="sys/rack-unit-1/bios/bios-settings/
OS-Boot-Watchdog-Timer-Param" vpOSBootWatchdogTimer="disabled"/>
<biosVfOSBootWatchdogTimerPolicy dn="sys/rack-unit-1/bios
/bios-settings/ OS-Boot-Watchdog-Timer-Policy"
vpOSBootWatchdogTimerPolicy="power-off"/>
<biosVfOSBootWatchdogTimerTimeout dn="sys/rack-unit-1/bios
/bios-settings/ OS-Boot-Watchdog-Timer-Time-Out"
vpOSBootWatchdogTimerTimeout="10-minutes"/>
<biosVfOutOfBandMgmtPort dn="sys/rack-unit-1/bios/bios-settings
/OoB-MgmtPort" vpOutOfBandMgmtPort="Enabled"/>
<biosVfPackageCStateLimit dn="sys/rack-unit-1/bios/bios-settings/
Package-CState-Limit" vpPackageCStateLimit="c3-state"/>
<biosVfPatrolScrub dn="sys/rack-unit-1/bios/bios-settings
/Patrol-Scrub-Param" vpPatrolScrub="enabled"/>
<biosVfPatrolScrubDuration dn="sys/rack-unit-1/bios/bios-settings/
Patrol-Scrub-Duration" vpPatrolScrubDuration="8"/>
<biosVfPCIOptionROMs dn="sys/rack-unit-1/bios/bios-settings
/PCI-OptionROMs" vpPCIOptionROMs="Legacy Only"/>
<biosVfPCISlotOptionROMEnable dn="sys/rack-unit-1/bios/bios-settings
/PCI-Slot-OptionROM-Enable" vpSlotMezzState="Enabled"
vpSlot7LinkSpeed="GEN3" vpSlot6LinkSpeed="GEN2"
vpSlot5LinkSpeed="GEN2" vpSlot4LinkSpeed="GEN2"
vpSlot3LinkSpeed="GEN2" vpSlot2LinkSpeed="GEN2"
vpSlot1LinkSpeed="GEN2" vpSlot10State="Enabled"
vpSlot9State="Enabled" vpSlot8State="Enabled"
vpSlot7State="Enabled" vpSlot6State="Enabled"
vpSlot5State="Enabled" vpSlot4State="Enabled"
vpSlot3State="Enabled" vpSlot2State="Enabled"
vpSlot1State="Enabled"/>
<biosVfPOSTErrorPause dn="sys/rack-unit-1/bios/bios-settings
/POST-error-pause" vpPOSTErrorPause="disabled"/>
<biosVfProcessorC1E dn="sys/rack-unit-1/bios/bios-settings
/Processor-C1E" vpProcessorC1E="enabled"/>
<biosVfProcessorC3Report dn="sys/rack-unit-1/bios
/bios-settings/Processor-C3-Report" vpProcessorC3Report="enabled"/>
<biosVfProcessorC6Report dn="sys/rack-unit-1/bios/bios-settings
/Processor-C6-Report" vpProcessorC6Report="enabled"/>
<biosVfProcessorCState dn="sys/rack-unit-1/bios/bios-settings
/Processor-C-State" vpProcessorCState="enabled"/>
<biosVfPStateCoordType dn="sys/rack-unit-1/bios
/bios-settings/p-state-coord" vpPStateCoordType="HW ALL"/>
<biosVfQPIConfig dn="sys/rack-unit-1/bios/bios-settings
/QPI-Config" vpQPILinkFrequency="auto"/>
<biosVfSelectMemoryRASConfiguration dn="sys/rack-unit-1/bios
/bios-settings/SelectMemory-RAS-configuration"
vpSelectMemoryRASConfiguration="sparing"/>
<!-- port A supported in Alpine and SM -->
<biosVfSerialPortAEnable dn="sys/rack-unit-1/bios/bios-settings
/Serial-port-A-enable" vpSerialPortAEnable="enabled"/>
<biosVfSparingMode dn="sys/rack-unit-1/bios/bios-settings
/Sparing-Mode" vpSparingMode="rank-sparing"/>
<biosVfSrIov dn="sys/rack-unit-1/bios/bios-settings/sr-iov"
vpSrIov="disabled"/>
<biosVfTPMSupport dn="sys/rack-unit-1/bios/bios-settings
/TPM-Support" vpTPMSupport="disabled"/>
<biosVfUCSMBootOrderRuleControl dn="sys/rack-unit-1/bios
/bios-settings/Boot-Order-Rules" vpUCSMBootOrderRule="Loose"/>
<biosVfUSBBootConfig dn="sys/rack-unit-1/bios/bios-settings
/USB-Boot-Config" vpMakeDeviceNonBootable="disabled"/>
<biosVfUSBEmulation dn="sys/rack-unit-1/bios/bios-settings
/USBEmulation-Support" vpUSBEmul6064="enabled"/>
<biosVfUSBPortsConfig dn="sys/rack-unit-1/bios/bios-settings
/USB-Ports-Config" vpUsbPortSDCard="enabled"
vpUsbPortVMedia="enabled" vpUsbPortKVM="enabled"
vpUsbPortInternal="enabled" vpUsbPortFront="enabled"
vpUsbPortRear="enabled" vpAllUsbDevices="enabled"/>
<biosVfVgaPriority dn="sys/rack-unit-1/bios/bios-settings
/VgaPriority" vpVgaPriority="Onboard"/>
</biosSettings>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/bios/bios-settings"
cookie="1379605932/898925a0-e6be-16be-922b-5bfca0114ca4" response="yes">
<outConfig>
<biosSettings dn="sys/rack-unit-1/bios/bios-settings" status="modified" >
<biosVfIntelVTForDirectedIO rn="Intel-VT-for-directed-IO"
vpIntelVTDATSSupport="enabled" vpIntelVTDCoherencySupport="disabled"
vpIntelVTForDirectedIO="enabled" status="modified" >
</biosVfIntelVTForDirectedIO><biosVfSelectMemoryRASConfiguration
rn="SelectMemory-RAS-configuration" vpSelectMemoryRASConfiguration=
"maximum-performance" status="modified" >
</biosVfSelectMemoryRASConfiguration>
<biosVfProcessorC6Report rn="Processor-C6-Report"
vpProcessorC6Report="enabled" status="modified" >
</biosVfProcessorC6Report>
<biosVfIntelHyperThreadingTec rn="Intel-HyperThreading-Tech"
vpIntelHyperThreadingTech="enabled" status="modified" >
</biosVfIntelHyperThreadingTech>
<biosVfEnhancedIntelSpeedStepTech rn="Enhanced-Intel-SpeedStep-Tech"
vpEnhancedIntelSpeedStepTech="enabled" status="modified" >
</biosVfEnhancedIntelSpeedStepTech>
<biosVfIntelVirtualizationTechnology rn="Intel-Virtualization-Technology"
vpIntelVirtualizationTechnology="enabled" status="modified" >
</biosVfIntelVirtualizationTechnology>
<biosVfMemoryMappedIOAbove4GB rn="Memory-mapped-IO-above-4GB"
vpMemoryMappedIOAbove4GB="enabled" status="modified" >
</biosVfMemoryMappedIOAbove4GB>
<biosVfCPUPerformance rn="CPU-Performance" vpCPUPerformance="enterprise"
status="modified" ></biosVfCPUPerformance>
<biosVfLvDIMMSupport rn="LvDIMM-Support" vpLvDDRMode="power-saving-mode"
status="modified" >
.
.
.
<biosVfUSBPortsConfig rn="USB-Ports-Config" vpAllUsbDevices="enabled"
vpUsbPortRear="enabled" vpUsbPortFront="enabled"
vpUsbPortInternal="enabled" vpUsbPortKVM="enabled"
vpUsbPortVMedia="enabled" status="modified" >
</biosVfUSBPortsConfig>
<biosVfQPIConfig rn="QPI-Config" vpQPILinkFrequency="auto"
status="modified" > </biosVfQPIConfig>
<biosVfOnboardStorage rn="Onboard-Storage" vpOnboardSCUStorageSupport="disabled"
status="modified" ></biosVfOnboardStorage>
<biosVfLegacyUSBSupport rn="LegacyUSB-Support" vpLegacyUSBSupport="enabled"
status="modified" ></biosVfLegacyUSBSupport>
<biosVfUSBEmulation rn="USBEmulation-Support" vpUSBEmul6064="enabled"
status="modified" ></biosVfUSBEmulation>
<biosVfUCSMBootOrderRuleControl rn="Boot-Order-Rules" vpUCSMBootOrderRule="Loose"
status="modified" > </biosVfUCSMBootOrderRuleControl>
<biosVfPCIOptionROMs rn="PCI-OptionROMs" vpPCIOptionROMs="Legacy Only"
status="modified" ></biosVfPCIOptionROMs>
<biosVfLOMPortOptionROM rn="LOMPort-OptionROM" vpLOMPortsAllState="Enabled"
vpLOMPort0State="Enabled" vpLOMPort1State="Enabled" status="modified" >
</biosVfLOMPortOptionROM>
<biosVfPCISlotOptionROMEnable rn="PCI-Slot-OptionROM-Enable"
vpSlot1State="Enabled" vpSlot2State="Enabled" vpSlot3State="Enabled"
vpSlot4State="Enabled" vpSlot5State="Enabled" vpSlot1LinkSpeed="GEN2"
vpSlot2LinkSpeed="GEN2" vpSlot3LinkSpeed="GEN2" vpSlot4LinkSpeed="GEN2"
vpSlot5LinkSpeed="GEN2" status="modified" >
</biosVfPCISlotOptionROMEnable><biosVfPStateCoordType
rn="p-state-coord" vpPStateCoordType="HW ALL" status="modified" >
</biosVfPStateCoordType><biosVfDramRefreshRate rn="dram-refresh-rate"
vpDramRefreshRate="Auto" status="modified" >
</biosVfDramRefreshRate>
<biosVfOutOfBandMgmtPort rn="OoB-MgmtPort" vpOutOfBandMgmtPort="Enabled"
status="modified" >
</biosVfOutOfBandMgmtPort>
</biosSettings>
</outConfig>
</configConfMo>
Retrieving TPM Information
Request:
<configResolveClass cookie='1382189754/215a42c8-e918-1918-8003-dafea0114ca4'
classId='equipmentTpm' inHierarchical='true'> </configResolveClass>"
Response:
<configResolveClass cookie="1383875054/8504b1f8-eaa0-1aa0-8005-140197ebfab0"
response="yes" classId="equipmentTpm">
<outConfigs>
<equipmentTpm dn="sys/rack-unit-1/board/tpm" presence="equipped"
enabledStatus="enabled" activeStatus="activated" ownership="unowned"
tpmRevision="1" model="UCSX-TPM1-001" vendor="Cisco Systems Inc"
serial="FCH1526749E" version="A" >
</equipmentTpm>
</outConfigs>
</configResolveClass>
Retrieving PCI Slot Information
Request:
<configResolveClass cookie='1307953743/b63ff130-a593-1593-8004-2e4ac2e14388'
classId='pciEquipSlot' inHierarchical='true'>
</configResolveClass>"
Response:
<configResolveClass cookie="0987076388/a17ea2c8-81bd-11bd-8003-4c40daf6083c" response="yes"
classId="pciEquipSlot">
<outConfigs>
<pciEquipSlot controllerReported="L" hostReported="NOTINCP-0" id="L"
macLeft="NOTINCP-00:00:00:00:00:00" macRight="NOTINCP-00:00:00:00:00:00"
model="Intel(R) I350 1 Gbps Network Controller" serial="NOTINCP-"
smbiosId="L" vendor="0x8086" version="0x80000B16-1.997.9"
dn="sys/rack-unit-1/equipped-slot-L">
</pciEquipSlot>
<pciEquipSlot controllerReported="HBA"
hostReported="NOTINCP-0" id="HBA" macLeft="NOTINCP-00:00:00:00:00:00"
macRight="NOTINCP-00:00:00:00:00:00" model="Cisco 12G SAS Modular Raid
Controller" serial="NOTINCP-" smbiosId="HBA" vendor="0x1000" version="N/A"
dn="sys/rack-unit-1/equipped-slot-HBA">
</pciEquipSlot>
</outConfigs>
</configResolveClass>
Retrieving DIMM Blacklisting Status
Request:
<configResolveClass
cookie="0987076388/a17ea2c8-81bd-11bd-8003-4c40daf6083c"
inHierarchical="false" classId="equipmentIndicatorLed"/>
Response:
<configResolveClass
cookie="0987076388/a17ea2c8-81bd-11bd-8003-4c40daf6083c" response="yes"
classId="equipmentIndicatorLed">
<outConfigs>
<equipmentIndicatorLed color="green" id="1" name="LED_PSU_STATUS"
operState="on" dn="sys/rack-unit-1/indicator-led-1">
</equipmentIndicatorLed><equipmentIndicatorLed color="green" id="2"
name="LED_TEMP_STATUS" operState="on" dn="sys/rack-unit-1/indicator-led-2">
</equipmentIndicatorLed><equipmentIndicatorLed color="green" id="3"
name="LED_FAN_STATUS" operState="on" dn="sys/rack-unit-1/indicator-led-3">
</equipmentIndicatorLed><equipmentIndicatorLed color="green" id="4"
name="LED_HLTH_STATUS" operState="on" dn="sys/rack-unit-1/indicator-led-4">
</equipmentIndicatorLed><equipmentIndicatorLed color="blue" id="5"
name="FP_ID_LED" operState="off" dn="sys/rack-unit-1/indicator-led-5">
</equipmentIndicatorLed><equipmentIndicatorLed color="green" id="0"
name="OVERALL_DIMM_STATUS" operState="on"
dn="sys/rack-unit-1/indicator-led-0">
</equipmentIndicatorLed>
</outConfigs>
</configResolveClass>
Retrieving Network Settings
Request:
<configResolveClass cookie="1428279919/7887a3d3-1303-1303-8002-4a791e1b0ff4"
inHierarchical="false" classId="mgmtIf"/>
Response:
<configResolveClass cookie="1428279919/7887a3d3-1303-1303-8002-4a791e1b0ff4"
response="yes" classId="mgmtIf">
<outConfigs>
<mgmtIf dn="sys/rack-unit-1/mgmt/if-1" description="Management Interface Network Settings" id="1"
extEnabled="yes" extIp="10.10.10.10" extMask="255.255.255.0" extGw="10.10.10.10"
ifType="physical" mac="F4:0F:1B:1E:79:4A" hostname="Unknown" dhcpEnable="no"
dnsUsingDhcp="no" ddnsEnable="yes" ddnsDomain="" dnsPreferred="72.163.128.140"
dnsAlternate="171.70.168.183" nicMode="dedicated" vicSlot="flex-lom" nicRedundancy="none"
vlanEnable="no" vlanId="1" vlanPriority="0" portProfile="" v6extEnabled="no"
v6extIp="::" v6extGw="::" v6prefix="64" v6linkLocal="::" v6SlaacIp="::"
v6dhcpEnable="no" v6dnsUsingDhcp="no" v6dnsPreferred="::"
v6dnsAlternate="::" subject="blade" autoNeg="disabled" adminNetSpeed="100Mbps"
adminDuplex="full" operNetSpeed="100Mbps" operDuplex="full"/>
</outConfigs>
</configResolveClass>
Enabling Auto-Negotiation
Request:
<configConfMo cookie="1439377526/06f404d9-1d1c-1d1c-8002-a2209f054ef4" inHierarchical="false">
<inConfig>
<mgmtIf dn="sys/rack-unit-1/mgmt/if-1" nicMode="dedicated" autoNeg="enabled"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="" cookie="1439377526/06f404d9-1d1c-1d1c-8002-a2209f054ef4"
response="yes">
<outConfig>
<mgmtIf
dn="sys/rack-unit-1/mgmt/if-1" description="Management Interface Network Settings"
id="1" extEnabled="yes" extIp="10.10.10.10" extMask="255.255.255.0"
extGw="10.10.10.10" ifType="physical" mac="F4:4E:05:9F:20:A2" hostname="Cxxx-FCH1841V1AZ"
dhcpEnable="no" dnsUsingDhcp="no" ddnsEnable="yes" ddnsDomain="" dnsPreferred="0.0.0.0"
dnsAlternate="0.0.0.0" nicMode="dedicated" vicSlot="flex-lom" nicRedundancy="none"
vlanEnable="no" vlanId="1" vlanPriority="0" portProfile="" v6extEnabled="no"
v6extIp="::" v6extGw="::" v6prefix="64" v6linkLocal="::" v6SlaacIp="::"
v6dhcpEnable="no" v6dnsUsingDhcp="no" v6dnsPreferred="::" v6dnsAlternate="::"
subject="blade" autoNeg="enabled" adminNetSpeed="auto" adminDuplex="auto"
operNetSpeed=“1Gbps" operDuplex=”full" status="modified"/>
</outConfig>
</configConfMo>
Disabling Auto-Negotiation
Request:
<configConfMo cookie="1439377526/06f404d9-1d1c-1d1c-8002-a2209f054ef4" inHierarchical="false">
<inConfig>
<mgmtIf dn="sys/rack-unit-1/mgmt/if-1" nicMode="dedicated" autoNeg="disabled"/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="" cookie="1439377526/06f404d9-1d1c-1d1c-8002-a2209f054ef4"
response="yes">
<outConfig>
<mgmtIf
dn="sys/rack-unit-1/mgmt/if-1" description="Management Interface Network Settings"
id="1" extEnabled="yes" extIp="10.10.10.10" extMask="255.255.255.0"
extGw="10.10.10.10" ifType="physical" mac="F4:4E:05:9F:20:A2" hostname="Cxxx-FCH1841V1AZ"
dhcpEnable="no" dnsUsingDhcp="no" ddnsEnable="yes" ddnsDomain="" dnsPreferred="0.0.0.0"
dnsAlternate="0.0.0.0" nicMode="dedicated" vicSlot="flex-lom" nicRedundancy="none"
vlanEnable="no" vlanId="1" vlanPriority="0" portProfile="" v6extEnabled="no"
v6extIp="::" v6extGw="::" v6prefix="64" v6linkLocal="::" v6SlaacIp="::"
v6dhcpEnable="no" v6dnsUsingDhcp="no" v6dnsPreferred="::" v6dnsAlternate="::"
subject="blade" autoNeg="disabled" adminNetSpeed="100Mbps"
adminDuplex="full" operNetSpeed="100Mbps" operDuplex="full"
status="modified"/>
</outConfig>
</configConfMo>
Configuring Network Port Speed and Duplex With Auto-negotiation in Disabled State
Request:
<configConfMo cookie="1439377526/06f404d9-1d1c-1d1c-8002-a2209f054ef4"
inHierarchical="false">
<inConfig>
<mgmtIf dn="sys/rack-unit-1/mgmt/if-1" nicMode="dedicated" autoNeg=”disabled”
adminNetSpeed=“10Mbps” adminDuplex=“half”/>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="" cookie="1439377526/06f404d9-1d1c-1d1c-8002-a2209f054ef4"
response="yes">
<outConfig>
<mgmtIf
dn="sys/rack-unit-1/mgmt/if-1" description="Management Interface Network Settings"
id="1" extEnabled="yes" extIp="10.10.10.10" extMask="255.255.255.0"
extGw="10.10.10.10" ifType="physical" mac="F4:4E:05:9F:20:A2" hostname="Cxxx-FCH1841V1AZ"
dhcpEnable="no" dnsUsingDhcp="no" ddnsEnable="yes" ddnsDomain="" dnsPreferred="0.0.0.0"
dnsAlternate="0.0.0.0" nicMode="dedicated" vicSlot="flex-lom" nicRedundancy="none"
vlanEnable="no" vlanId="1" vlanPriority="0" portProfile="" v6extEnabled="no" v6extIp="::"
v6extGw="::" v6prefix="64" v6linkLocal="::" v6SlaacIp="::" v6dhcpEnable="no"
v6dnsUsingDhcp="no" v6dnsPreferred="::" v6dnsAlternate="::" subject="blade"
autoNeg="enabled" adminNetSpeed=”10Mbps" adminDuplex=”half"
operNetSpeed=“10Mbps" operDuplex=”half" status="modified"/>
</outConfig>
</configConfMo>
Configuring Network Settings to Enable DDNS
Request:
<configConfMo cookie='0987076803/ba395308-81bd-11bd-8004-4c40daf6083c'
dn='sys/rack-unit-1/mgmt/if-1'>
<inConfig>
<mgmtIf dn='sys/rack-unit-1/mgmt/if-1' ddnsDomain='www.cisco.com'/>
</inConfig>
</configConfMo>
Response:
This enables the DDNS.
<configConfMo dn="sys/rack-unit-1/mgmt/if-1"
cookie="1398652603/2f9bf4c8-f811-1811-8005-79bdaa4c93a4" response="yes">
<outConfig>
<mgmtIf dn="sys/rack-unit-1/mgmt/if-1" description="Management Interface
Network Settings" id="1" extEnabled="yes" extIp="10.10.10.10"
extMask="255.255.255.128" extGw="10.10.10.10" ifType="physical"
mac="A4:93:4C:AA:BD:79" hostname="ucs-Cxxx-mx" dhcpEnable="no"
dnsUsingDhcp="no" ddnsEnable="no" ddnsDomain="www.cisco.com"
dnsPreferred="0.0.0.0" dnsAlternate="0.0.0.0" nicMode="shared_lom"
nicRedundancy="active-active" vlanEnable="no" vlanId="1" vlanPriority="0"
portProfile="test" v6extEnabled="no" v6extIp="::"
v6extGw="::"v6prefix="64" v6linkLocal="::" v6dhcpEnable="no"
v6dnsUsingDhcp="no" v6dnsPreferred="::" v6dnsAlternate="::"
subject="blade" status="modified">
</mgmtIf>
</outConfig>
</configConfMo>
Creating PXE Boot Device
Request:
<configConfMo cookie='1390349461/f5c79390-f083-1083-8005-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootPxe name='pxe_slot1_port1' slot='1' port='1'
state='Enabled' dn='sys/rack-unit-1/boot-precision/pxe-pxe_slot1_port1'
rn='pxe-pxe_slot1_port1'/>
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390349461/f5c79390-f083-1083-8005-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision" name="boot-precision"
purpose="operational" rebootOnUpdate="no" bootMode="Legacy" status="modified" >
<lsbootVMedia name="kvm-fdd" type="VMEDIA" subtype="kvm-mapped-dvd" access=
"read-only-local" order="1" state="Enabled" rn="vm-kvm-fdd"
status="modified" >
</lsbootVMedia>
<lsbootPxe name="pxe" type="PXE" slot='1' port='1' order="2" state="Enabled"
rn="pxe-pxe" status="modified" >
</lsbootPxe>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Deleting PXE Boot Device
Request:
<configConfMo cookie='1390433433/82e32da8-f097-1097-8005-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootPxe name='PXE9' slot='9' port='' order='3' state='Enabled'
status='deleted' />
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390433433/82e32da8-f097-1097-8005-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision" name="boot-precision"
purpose="operational" rebootOnUpdate="no" bootMode="Legacy" reapply="no"
status="modified" >
<lsbootPxe name="PXE1" type="PXE" slot="9" order="2" state="Enabled" rn="pxe-PXE1"
status="modified">
<lsbootVMedia name="kvm-fdd" type="VMEDIA" subtype="kvm-mapped-dvd" access= "read-only-local"
order="1" state="Enabled" rn="vm-kvm-fdd" status="modified">
</lsbootPxe>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Modifying PXE Boot Device
Request:
<configConfMo cookie='1390882671/1b905748-f100-1100-8006-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootPxe name='pxe_slot1_port1' slot='2' port='1'
state='Enabled' dn='sys/rack-unit-1/boot-precision/pxe-pxe_slot1_port1'
order='1'
rn='pxe-pxe_slot1_port1' />
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390882671/1b905748-f100-1100-8006-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" reapply="no" status="modified" >
<lsbootVMedia name="kvm-fdd" type="VMEDIA" subtype="kvm-mapped-dvd"
access= "read-only-local" order="1" state="Enabled" rn="vm-kvm-fdd"
status="modified" >
</lsbootVMedia>
<lsbootPxe name="pxe_slot1_port1" type="PXE" slot="1"
port="1" order="1" state="Enabled" rn="pxe-pxe_slot1_port1"
status="modified">
</lsbootPxe>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Creating ISCSI Boot Device
Request:
<configConfMo cookie='1390443548/ddc28938-f099-1099-8007-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootIscsi name='myISCSIfist-device' slot='1' port='1'
order='4' state='Enabled'
dn='sys/rack-unit-1/boot-precision/iscsi-myISCSIfist-device'
rn='iscsi-myISCSIfist-device' />
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390443548/ddc28938-f099-1099-8007-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" status="modified" >
<lsbootPxe name="PXE5" type="PXE" slot="9" order="1" state="Disabled"
rn="pxe-PXE5" status="modified" >
</lsbootPxe>
<lsbootPxe name="PXE1" type="PXE" slot="9" order="2" state="Enabled"
rn="pxe-PXE1" status="modified" >
</lsbootPxe>
<lsbootIscsi name="Iscsi" type="ISCSI" order="3" state="Disabled"
rn="iscsi-Iscsi" status="modified" >
</lsbootIscsi>
<lsbootIscsi name="myISCSIfist-device" type="ISCSI" slot="1"
port="1" order="4" state="Enabled" rn="iscsi-myISCSIfist-device"
status="modified" >
</lsbootIscsi>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Deleting ISCSI Boot Device
Request:
<configConfMo cookie='1390451709/c43d08b0-f09b-109b-800a-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootIscsi name='iscsi105' slot='3' port='6' order='1'
state='Enabled' status='removed'/>
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390451709/c43d08b0-f09b-109b-800a-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" status="modified" >
<lsbootIscsi name="iscsi105" type="ISCSI" slot="3" port="6" order="1"
state="Enabled" rn="iscsi-iscsi105" status="modified">
</lsbootIscsi>
<lsbootIscsi name="iscsi101" type="ISCSI" slot="3"
port="6" order="2" state="Enabled" rn="iscsi-iscsi101"
status="modified">
</lsbootIscsi>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Modifying ISCSI Boot Device
Request:
<configConfMo cookie='1390451709/c43d08b0-f09b-109b-800a-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootIscsi name='iscsi109' slot='100' port='100' order='1'
state='Disabled'/>
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390451709/c43d08b0-f09b-109b-800a-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" status="modified" >
<lsbootIscsi name="iscsi106" type="ISCSI" slot="3" port="6" order="1"
state="Enabled" rn="iscsi-iscsi106" status="modified">
</lsbootIscsi>
<lsbootIscsi name="iscsi105" type="ISCSI" slot="3" port="6" order="2"
state="Enabled" rn="iscsi-iscsi105" status="modified" >
</lsbootIscsi>
<lsbootIscsi name="iscsi109" type="ISCSI" slot="1" port="9" order="3"
state="Disabled" rn="iscsi-iscsi109" status="modified">
</lsbootIscsi>
<lsbootIscsi name="iscsi101" type="ISCSI" slot="3" port="6" order="4"
state="Enabled" rn="iscsi-iscsi101" status="modified">
</lsbootIscsi>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Creating SAN Boot Device
Request:
<configConfMo cookie='1390514059/489111c0-f0aa-10aa-800b-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootSan name='mysanboot3' slot='100' lun='100'
order='1' state='Enabled' dn='sys/rack-unit-1/boot-precision/san- mysanboot3'
rn='san-mysanboot3'/>
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390514059/489111c0-f0aa-10aa-800b-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" status="modified" >
<lsbootSan name="mysanboot3" type="SAN" slot="100"
lun="100" order="1" state="Enabled" rn="san-mysanboot3"
status="modified">
</lsbootSan>
<lsbootSan name="mysanboot" type="SAN" order="2" state="Disabled"
rn="san-mysanboot" status="modified">
</lsbootSan>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Deleting SAN Boot Device
Request:
<configConfMo cookie='1390535353/3dc6e2b0-f0af-10af-8002-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootSan name='san16' slot='1' lun='9'
order='1' state='Enabled' status='removed'/>
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390535353/3dc6e2b0-f0af-10af-8002-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" status="modified" >
<lsbootPxe name="pxe" type="PXE" slot="1" port="1" order="4"
state="Enabled" rn="pxe-pxe" status="modified">
</lsbootPxe>
<lsbootHdd name="myhdd" type="LOCALHDD" slot="1" lun="3" order="5"
state="Enabled" rn="hdd-myhdd" status="modified">
</lsbootHdd>
<lsbootSan name="san16" type="SAN" slot="1" lun="9" order="1"
state="Enabled" rn="san-san16" status="modified">
</lsbootSan>
<lsbootSan name="san10" type="SAN" slot="1" lun="9" order="2"
state="Disabled" rn="san-san10" status="modified">
</lsbootSan>
<lsbootSan name="san9" type="SAN" slot="1" lun="9" order="3"
state="Enabled" rn="san-san9" status="modified">
</lsbootSan>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Modifying SAN Boot Device
Request:
<configConfMo cookie='1390535353/3dc6e2b0-f0af-10af-8002-93536d0df730'
dn='sys/rack-unit-1/boot-precision' inHierarchical='true'>
<inConfig>
<lsbootDevPrecision dn='sys/rack-unit-1/boot-precision' rebootOnUpdate='no'
status='modified'>
<lsbootSan name='san9' slot='99' lun='99' order='1'
state='Disabled' />
</lsbootDevPrecision>
</inConfig>
</configConfMo>
Response:
<configConfMo dn="sys/rack-unit-1/boot-precision"
cookie="1390535353/3dc6e2b0-f0af-10af-8002-93536d0df730" response="yes">
<outConfig>
<lsbootDevPrecision dn="sys/rack-unit-1/boot-precision"
name="boot-precision" purpose="operational" rebootOnUpdate="no"
bootMode="Legacy" status="modified" >
<lsbootSan name="san9" type="SAN" slot="1" lun="9"
order="1" state="Enabled" rn="san-san9" status="modified" >
</lsbootSan>
</lsbootDevPrecision>
</outConfig>
</configConfMo>
Retrieving a System Generated Password for the User
Request:
<configResolveClass cookie="0000257903/822c9ad3-003c-103c-800a-d06f72ebfab0"
response="yes" classId="generateRandomPassword">
<outConfigs>
Response:
<outConfigs>
<generateRandomPassword dn="sys/user-ext/generate-random-pwd" password="yS!7_DF7"/>
</outConfigs>
</configResolveClass>