Fabric Interconnect Components Alarms
Following table shows the description of the supported alarms for Fabric Interconnect components.
Name | MO | Severity | Explanation | Recommended Action |
---|---|---|---|---|
PeerFirmwareOutOfSync | network.element | Info | This alarm is triggered when there is a discrepancy in the firmware version between peer fabric interconnects, indicating that they are not synchronized. |
|
fpgaUpgrade | network.Element | Critical | This alarm occurs when you update to Infrastructure Release 4.1(3) or a later version on Cisco UCS 6400 Series Fabric Interconnects, you may notice a specific message on one or both Fabric Interconnects, depending on the original factory-shipped code for the device. There is no production risk involved. However, it's important to note that the security level may be slightly lower. | To enhance the security of your Field-Programmable Gate Array (FPGA), execute the 'activate secure-fpga' command on the target device through your console's Command Line Interface (CLI). For more information, see Intersight Help Center. |
NetworkSwitchEvacuated |
network.Element |
Info |
This alarm is triggered when the Fabric Interconnect is evacuated. For example, Evacuation enabled for DomainName/switch-B. |
Disable the Fabric Evacuation on the Fabric Interconnect for the alarm to get cleared. |
SwitchFanModuleInoperable | equipment.FanModule | Critical | This alarm occurs if a fan module is not operational. It can occur when one or more fans in a fan module are not operational. |
|
SwitchFanInoperable | equipment.Fan | Critical | This alarm occurs if a fan is not operational. |
|
SwitchFanPoweredOff | equipment.Fan | Critical | This alarm occurs if a fan is shutdown. |
|
SwitchPsuInoperable | equipment.Psu | Critical | This alarm occurs if a Power Supply is not operational. |
|
SwitchPsuPoweredOff | equipment.Psu | Critical | This alarm occurs if a Power Supply is powered off either due to higher than expected power or due to higher than expected temperatures, or because of the failure of a fan. |
|
VlanPortCountThreshold | network.VlanPortInfo | Warning | This alarm typically occurs when the total number of configured VLANs in the Cisco UCS instance has exceeded 90% of the allowed maximum number of configured VLANs on the Fabric Interconnect. |
|
VlanPortCountExceeded | network.VlanPortInfo | Critical | This alarm typically occurs when the total number of configured VLANs in the Cisco UCS instance has exceeded the allowed maximum number of configured VLANs on the Fabric Interconnect. |
|
SwitchDisconnected | network.Element | Critical | This alarm typically occurs when device cannot connect to Intersight. It can occur when a power cable is disconnected or input voltage is incorrect. |
|
SwitchInoperable | network.Element | Critical | This alarm typically occurs when the device connector reports that the connectivity state of this switch is down. |
|
SwitchEvacuated | network.Element | Info | This alarm typically occurs when the switch is evacuated. |
|
SwitchThermalError | network.Element | Warning | This alarm occurs when the temperature of a Fabric Interconnect exceeds a critical threshold value. |
|
EtherTransceiverNotPresent |
network.Element | Info |
When a switch port is not in an unconfigured state, an SFP is required for its operation. This alarm is raised to indicate that the either SFP is faulty or missing from a configured port. |
If you see this fault, insert a supported SFP into the port on the Fabric Interconnect. Refer to the documentation on the Cisco website for a list of supported SFPs. |
EtherPortLinkDown |
network.Element | Warning |
This alarm occurs when a Fabric Interconnect port is in link-down state. This state impacts the traffic destined for the port. |
|
FcPcLinkDown |
network.Element | Warning |
This fault occurs when a Fabric Interconnect port channel is in link-down state. This state impacts the traffic destined for the port channel. |
|
FcPortLinkDown |
network.Element | Warning |
This fault occurs when a Fabric Interconnect port is in link-down state. This state impacts the traffic destined for the port. |
|
FcTransceiverNotPresent |
network.Element | Info |
When a switch port is not in an unconfigured state, an SFP is required for its operation. This alarm is raised to indicate that the SFP is missing from a configured port. |
If you see this fault, insert a supported SFP into the port on the Fabric Interconnect. Refer to the documentation on the Cisco website for a list of supported SFPs. |