Software Configuration Guide, Cisco IOS Release 15.2(3)E and Later (Catalyst 3750-X and 3560-X Switches)
Bias-Free Language
The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
Configuring IEEE
802.1Q and Layer 2 Protocol Tunneling
Finding Feature
Information
Your software release
may not support all the features documented in this module. For the latest
caveats and feature information, see Bug Search Tool and the release notes for
your platform and software release. To find information about the features
documented in this module, and to see a list of the releases in which each
feature is supported, see the feature information table at the end of this
module.
Use Cisco Feature
Navigator to find information about platform support and Cisco software image
support. To access Cisco Feature Navigator, go to
http://www.cisco.com/go/cfn.
An account on Cisco.com is not required.
Prerequisites for Configuring Tunneling
The following sections list prerequisites and considerations for configuring IEEE 802.1Q and Layer 2 protocol tunneling.
IEEE 802.1Q
Tunneling
Although IEEE 802.1Q
tunneling works well for Layer 2 packet switching, there are incompatibilities
between some Layer 2 features and Layer 3 switching.
A tunnel port
cannot be a routed port.
IP routing is not
supported on a VLAN that includes IEEE 802.1Q ports. Packets received from a
tunnel port are forwarded based only on Layer 2 information. If routing is
enabled on a
switch virtual interface (SVI) that includes
tunnel ports, untagged IP packets received from the tunnel port are recognized
and routed by the
switch. Customers can access the Internet
through its native VLAN. If this access is not needed, you should not configure
SVIs on VLANs that include tunnel ports.
Fallback bridging
is not supported on tunnel ports. Because all IEEE 802.1Q-tagged packets
received from a tunnel port are treated as non-IP packets, if fallback bridging
is enabled on VLANs that have tunnel ports configured, IP packets would be
improperly bridged across VLANs. Therefore, you must not enable fallback
bridging on VLANs with tunnel ports.
Tunnel ports do
not support IP access control lists (ACLs).
Layer 3 quality of
service (QoS) ACLs and other QoS features related to Layer 3 information are
not supported on tunnel ports. MAC-based QoS is supported on tunnel ports.
EtherChannel port
groups are compatible with tunnel ports as long as the IEEE 802.1Q
configuration is consistent within an EtherChannel port group.
Port Aggregation
Protocol (PAgP), Link Aggregation Control Protocol (LACP), and UniDirectional
Link Detection (UDLD) are supported on IEEE 802.1Q tunnel ports.
Dynamic Trunking
Protocol (DTP) is not compatible with IEEE 802.1Q tunneling because you must
manually configure asymmetric links with tunnel ports and trunk ports.
VLAN Trunking
Protocol (VTP) does not work between devices that are connected by an
asymmetrical link or devices that communicate through a tunnel.
Loopback detection
is supported on IEEE 802.1Q tunnel ports.
When a port is
configured as an IEEE 802.1Q tunnel port, spanning-tree bridge protocol data
unit (BPDU) filtering is automatically enabled on the interface. Cisco
Discovery Protocol (CDP) and the Layer Link Discovery Protocol (LLDP) are
automatically disabled on the interface.
Layer 2 Protocol
Tunneling
The
switch
supports tunneling of CDP, STP, including multiple STP (MSTP), and VTP.
Protocol tunneling is disabled by default but can be enabled for the individual
protocols on IEEE 802.1Q tunnel ports or access ports.
The
switch
does not support Layer 2 protocol tunneling on ports with switchport mode
dynamic auto or dynamic desirable.
DTP is not
compatible with layer 2 protocol tunneling.
The edge
switches
on the outbound side of the service-provider network restore the proper Layer 2
protocol and MAC address information and forward the packets to all tunnel and
access ports in the same metro VLAN.
For
interoperability with third-party vendor
switches,
the
switch
supports a Layer 2 protocol-tunnel bypass feature. Bypass mode transparently
forwards control PDUs to vendor
switches
that have different ways of controlling protocol tunneling. When Layer 2
protocol tunneling is enabled on ingress ports on a
switch,
egress trunk ports forward the tunneled packets with a special encapsulation.
If you also enable Layer 2 protocol tunneling on the egress trunk port, this
behavior is bypassed, and the
switch
forwards control PDUs without any processing or modification.
The
switch
supports PAgP, LACP, and UDLD tunneling for emulated point-to-point network
topologies. Protocol tunneling is disabled by default but can be enabled for
the individual protocols on IEEE 802.1Q tunnel ports or on access ports.
If you enable PAgP
or LACP tunneling, we recommend that you also enable UDLD on the interface for
faster link-failure detection.
Loopback detection
is not supported on Layer 2 protocol tunneling of PAgP, LACP, or UDLD packets.
EtherChannel port
groups are compatible with tunnel ports when the IEEE 802.1Q configuration is
consistent within an EtherChannel port group.
If an encapsulated
PDU (with the proprietary destination MAC address) is received from a tunnel
port or an access port with Layer 2 tunneling enabled, the tunnel port is shut
down to prevent loops. The port also shuts down when a configured shutdown
threshold for the protocol is reached. You can manually reenable the port (by
entering a
shutdown and a
no shutdown
command sequence). If errdisable recovery is enabled, the operation is retried
after a specified time interval.
Only decapsulated
PDUs are forwarded to the customer network. The spanning-tree instance running
on the service-provider network does not forward BPDUs to tunnel ports. CDP
packets are not forwarded from tunnel ports.
When protocol
tunneling is enabled on an interface, you can set a per-protocol, per-port,
shutdown threshold for the PDUs generated by the customer network. If the limit
is exceeded, the port shuts down. You can also limit BPDU rate by using QoS
ACLs and policy maps on a tunnel port.
When protocol
tunneling is enabled on an interface, you can set a per-protocol, per-port,
drop threshold for the PDUs generated by the customer network. If the limit is
exceeded, the port drops PDUs until the rate at which it receives them is below
the drop threshold.
Because tunneled
PDUs (especially STP BPDUs) must be delivered to all remote sites so that the
customer virtual network operates properly, you can give PDUs higher priority
within the service-provider network than data packets received from the same
tunnel port. By default, the PDUs use the same CoS value as data packets.
Layer 2 Tunneling
for EtherChannels
To configure Layer 2
point-to-point tunneling to facilitate the automatic creation of EtherChannels,
you need to configure both the SP (service-provider) edge switch and the
customer
switch.
Information about Tunneling
IEEE 802.1Q and
Layer 2 Protocol Overview
Virtual private
networks (VPNs) provide enterprise-scale connectivity on a shared
infrastructure, often Ethernet-based, with the same security, prioritization,
reliability, and manageability requirements of private networks. Tunneling is a
feature designed for service providers who carry traffic of multiple customers
across their networks and are required to maintain the VLAN and Layer 2
protocol configurations of each customer without impacting the traffic of other
customers.
For complete syntax
and usage information for the commands used in this chapter, see the command
reference for this release.
IEEE 802.1Q
Tunneling
Business customers of
service providers often have specific requirements for VLAN IDs and the number
of VLANs to be supported. The VLAN ranges required by different customers in
the same service-provider network might overlap, and traffic of customers
through the infrastructure might be mixed. Assigning a unique range of VLAN IDs
to each customer would restrict customer configurations and could easily exceed
the VLAN limit (4096) of the IEEE 802.1Q specification.
Using the IEEE 802.1Q
tunneling feature, service providers can use a single VLAN to support customers
who have multiple VLANs. Customer VLAN IDs are preserved, and traffic from
different customers is segregated within the service-provider network, even
when they appear to be in the same VLAN. Using IEEE 802.1Q tunneling expands
VLAN space by using a VLAN-in-VLAN hierarchy and retagging the tagged packets.
A port configured to support IEEE 802.1Q tunneling is called a tunnel port.
When you configure tunneling, you assign a tunnel port to a VLAN ID that is
dedicated to tunneling. Each customer requires a separate service-provider VLAN
ID, but that VLAN ID supports all of the customer’s VLANs.
Customer traffic
tagged in the normal way with appropriate VLAN IDs comes from an IEEE 802.1Q
trunk port on the customer device and into a tunnel port on the
service-provider edge
switch.
The link between the customer device and the edge
switch
is asymmetric because one end is configured as an IEEE 802.1Q trunk port, and
the other end is configured as a tunnel port. You assign the tunnel port
interface to an access VLAN ID that is unique to each customer.
Packets coming from
the customer trunk port into the tunnel port on the service-provider edge
switch
are normally IEEE 802.1Q-tagged with the appropriate VLAN ID. The tagged
packets remain intact inside the
switch
and when they exit the trunk port into the service-provider network, they are
encapsulated with another layer of an IEEE 802.1Q tag (called the metro tag)
that contains the VLAN ID that is unique to the customer. The original customer
IEEE 802.1Q tag is preserved in the encapsulated packet. Therefore, packets
entering the service-provider network are double-tagged, with the outer (metro)
tag containing the customer’s access VLAN ID, and the inner VLAN ID being that
of the incoming traffic.
When the double-tagged
packet enters another trunk port in a service-provider core
switch,
the outer tag is stripped as the
switch
processes the packet. When the packet exits another trunk port on the same core
switch,
the same metro tag is again added to the packet.
When the packet enters
the trunk port of the service-provider egress
switch,
the outer tag is again stripped as the
switch
internally processes the packet. However, the metro tag is not added when the
packet is sent out the tunnel port on the edge
switch
into the customer network. The packet is sent as a normal IEEE 802.1Q-tagged
frame to preserve the original VLAN numbers in the customer network.
In the above network
figure, Customer A was assigned VLAN 30, and Customer B was assigned VLAN 40.
Packets entering the edge
switch
tunnel ports with IEEE 802.1Q tags are double-tagged when they enter the
service-provider network, with the outer tag containing VLAN ID 30 or 40,
appropriately, and the inner tag containing the original VLAN number, for
example, VLAN 100. Even if both Customers A and B have VLAN 100 in their
networks, the traffic remains segregated within the service-provider network
because the outer tag is different. Each customer controls its own VLAN
numbering space, which is independent of the VLAN numbering space used by other
customers and the VLAN numbering space used by the service-provider network.
At the outbound tunnel
port, the original VLAN numbers on the customer’s network are recovered. It is
possible to have multiple levels of tunneling and tagging, but the
switch
supports only one level in this release.
If traffic coming from
a customer network is not tagged (native VLAN frames), these packets are
bridged or routed as normal packets. All packets entering the service-provider
network through a tunnel port on an edge
switch
are treated as untagged packets, whether they are untagged or already tagged
with IEEE 802.1Q headers. The packets are encapsulated with the metro tag VLAN
ID (set to the access VLAN of the tunnel port) when they are sent through the
service-provider network on an IEEE 802.1Q trunk port. The priority field on
the metro tag is set to the interface class of service (CoS) priority
configured on the tunnel port. (The default is zero if none is configured.)
On
switches,
because 802.1Q tunneling is configured on a per-port basis, it does not matter
whether the
switch
is a standalone
switch
or a stack member. All configuration is done on the stack master.
IEEE 802.1Q Tunneling Configuration Guidelines
When you configure IEEE 802.1Q tunneling, you should always use an asymmetrical link between the customer device and the edge
switch, with the customer device port configured as an IEEE 802.1Q trunk port and the edge switch port configured as a tunnel port.
Assign tunnel ports only to VLANs that are used for tunneling.
Configuration requirements for native VLANs and for and maximum transmission units (MTUs) are explained in these next sections.
Native VLANs
When configuring IEEE
802.1Q tunneling on an edge
switch,
you must use IEEE 802.1Q trunk ports for sending packets into the
service-provider network. However, packets going through the core of the
service-provider network can be carried through IEEE 802.1Q trunks, ISL trunks,
or nontrunking links. When IEEE 802.1Q trunks are used in these core
switches,
the native VLANs of the IEEE 802.1Q trunks must not match any native VLAN of
the nontrunking (tunneling) port on the same
switch
because traffic on the native VLAN would not be tagged on the IEEE 802.1Q
sending trunk port.
In the following
network figure, VLAN 40 is configured as the native VLAN for the IEEE 802.1Q
trunk port from Customer X at the ingress edge
switch
in the service-provider network (Switch
B).
Switch
A of Customer X sends a tagged packet on VLAN 30 to the ingress tunnel port of
Switch
B in the service-provider network, which belongs to access VLAN 40. Because the
access VLAN of the tunnel port (VLAN 40) is the same as the native VLAN of the
edge
switch
trunk port (VLAN 40), the metro tag is not added to tagged packets received
from the tunnel port. The packet carries only the VLAN 30 tag through the
service-provider network to the trunk port of the egress-edgeswitch
(Switch
C) and is misdirected through the egress
switch
tunnel port to Customer Y.
These are some ways to solve this problem:
Use ISL trunks between core
switchesin
the service-provider network. Although customer interfaces connected to edge
switches
must be IEEE 802.1Q trunks, we recommend using ISL trunks for connecting
switches
in the core layer.
Use the
vlan dot1q tag native global configuration
command to configure the edge
switches
so that all packets going out an IEEE 802.1Q trunk, including the native VLAN,
are tagged. If the
switches
is configured to tag native VLAN packets on all IEEE 802.1Q trunks, the
switches
accepts untagged packets, but sends only tagged packets.
Ensure that the native VLAN ID on the edge
switches
trunk port is not within the customer VLAN range. For example, if the trunk
port carries traffic of VLANs 100 to 200, assign the native VLAN a number
outside that range.
System MTU
The default system MTU
for traffic on the
switch
is 1500 bytes.
You can configure Fast
Ethernet ports on the
switch
members in the mixed hardware
switch
stack to support frames larger than 1500 bytes by using the system mtu global configuration command.
You can configure
10-Gigabit and Gigabit Ethernet ports to support frames larger than 1500 bytes
by using the system mtu
jumbo global configuration command.
The system MTU and
system jumbo MTU values do not include the IEEE 802.1Q header. Because the IEEE
802.1Q tunneling feature increases the frame size by 4 bytes when the metro tag
is added, you must configure all
switches
in the service-provider network to be able to process maximum frames by adding
4 bytes to the system MTU and system jumbo MTU sizes.
For example, the
switch
supports a maximum frame size of 1496 bytes with one of these configurations:
The
switch
has a system jumbo MTU value of 1500 bytes, and the switchport mode dot1q tunnel interface
configuration command is configured on a 10-Gigabit or Gigabit Ethernet
switch
port.
The
switch
member has a system MTU value of 1500 bytes, and the
switchport mode dot1q
tunnel interface configuration command is configured on a Fast
Ethernet port of the member.
Default IEEE 802.1Q Tunneling Configuration
By default, IEEE 802.1Q tunneling is disabled because the default switchport mode is dynamic auto. Tagging of IEEE 802.1Q
native VLAN packets on all IEEE 802.1Q trunk ports is also disabled.
Layer 2 Protocol
Tunneling Overview
Customers at different
sites connected across a service-provider network need to use various Layer 2
protocols to scale their topologies to include all remote sites, as well as the
local sites. STP must run properly, and every VLAN should build a proper
spanning tree that includes the local site and all remote sites across the
service-provider network. Cisco Discovery Protocol (CDP) must discover
neighboring Cisco devices from local and remote sites. VLAN Trunking Protocol
(VTP) must provide consistent VLAN configuration throughout all sites in the
customer network.
When protocol
tunneling is enabled, edge
switches
on the inbound side of the service-provider network encapsulate Layer 2
protocol packets with a special MAC address and send them across the
service-provider network. Core
switches
in the network do not process these packets but forward them as normal packets.
Layer 2 protocol data units (PDUs) for CDP, STP, or VTP cross the
service-provider network and are delivered to customer
switches
on the outbound side of the service-provider network. Identical packets are
received by all customer ports on the same VLANs with these results:
Users on each of a
customer’s sites can properly run STP, and every VLAN can build a correct
spanning tree based on parameters from all sites and not just from the local
site.
CDP discovers and
shows information about the other Cisco devices connected through the
service-provider network.
VTP provides
consistent VLAN configuration throughout the customer network, propagating to
all
switches
through the service provider.
Note
To provide
interoperability with third-party vendors, you can use the Layer 2
protocol-tunnel bypass feature. Bypass mode transparently forwards control PDUs
to vendor
switches
that have different ways of controlling protocol tunneling. You implement
bypass mode by enabling Layer 2 protocol tunneling on the egress trunk port.
When Layer 2 protocol tunneling is enabled on the trunk port, the encapsulated
tunnel MAC address is removed and the protocol packets have their normal MAC
address.
Layer 2 protocol
tunneling can be used independently or can enhance IEEE 802.1Q tunneling. If
protocol tunneling is not enabled on IEEE 802.1Q tunneling ports, remoteswitches
at the receiving end of the service-provider network do not receive the PDUs
and cannot properly run STP, CDP, and VTP. When protocol tunneling is enabled,
Layer 2 protocols within each customer’s network are totally separate from
those running within the service-provider network. Customer
switches
on different sites that send traffic through the service-provider network with
IEEE 802.1Q tunneling achieve complete knowledge of the customer’s VLAN. If
IEEE 802.1Q tunneling is not used, you can still enable Layer 2 protocol
tunneling by connecting to the customer
switch
through access ports and by enabling tunneling on the service-provider access
port.
For example, in the
following figure (Layer 2 Protocol Tunneling), Customer X has four
switches
in the same VLAN, that are connected through the service-provider network. If
the network does not tunnel PDUs,
switches
on the far ends of the network cannot properly run STP, CDP, and VTP. For
example, STP for a VLAN on a
switch
in Customer X, Site 1, will build a spanning tree on theswitches
at that site without considering convergence parameters based on Customer X’s
switch
in Site 2. This could result in the topology shown in the Layer 2 Network
Topology without Proper Convergence figure.
In an SP network, you
can use Layer 2 protocol tunneling to enhance the creation of EtherChannels by
emulating a point-to-point network topology. When you enable protocol tunneling
(PAgP or LACP) on the SP
switch,
remote customer
switches
receive the PDUs and can negotiate the automatic creation of EtherChannels.
For example, in the
following figure (Layer 2 Protocol Tunneling for EtherChannels), Customer A has
two
switches
in the same VLAN that are connected through the SP network. When the network
tunnels PDUs,
switches
on the far ends of the network can negotiate the automatic creation of
EtherChannels without needing dedicated lines.
Layer 2 Protocol
Tunneling on Ports
You can enable Layer 2
protocol tunneling (by protocol) on the ports that are connected to the
customer in the edge
switches
of the service-provider network. The service-provider edge
switches
connected to the customer
switch
perform the tunneling process. Edge
switch
tunnel ports are connected to customer IEEE 802.1Q trunk ports. Edge
switch
access ports are connected to customer access ports. The edge
switches
connected to the customer
switch
perform the tunneling process.
You can enable Layer 2
protocol tunneling on ports that are configured as access ports or tunnel
ports. You cannot enable Layer 2 protocol tunneling on ports configured in
either
switchport mode dynamic
auto mode (the default mode) or
switchport mode dynamic
desirable mode.
The
switch
supports Layer 2 protocol tunneling for CDP, STP, and VTP. For emulated
point-to-point network topologies, it also supports PAgP, LACP, and UDLD
protocols. The
switch
does not support Layer 2 protocol tunneling for LLDP.
Note
PAgP, LACP, and UDLD
protocol tunneling is only intended to emulate a point-to-point topology. An
erroneous configuration that sends tunneled packets to many ports could lead to
a network failure.
When the Layer 2 PDUs
that entered the service-provider inbound edge
switch
through a Layer 2 protocol-enabled port exit through the trunk port into the
service-provider network, the
switch
overwrites the customer PDU-destination MAC address with a well-known Cisco
proprietary multicast address (01-00-0c-cd-cd-d0). If IEEE 802.1Q tunneling is
enabled, packets are also double-tagged; the outer tag is the customer metro
tag, and the inner tag is the customer’s VLAN tag. The core
switches
ignore the inner tags and forward the packet to all trunk ports in the same
metro VLAN. The edge
switches
on the outbound side restore the proper Layer 2 protocol and MAC address
information and forward the packets to all tunnel or access ports in the same
metro VLAN. Therefore, the Layer 2 PDUs remain intact and are delivered across
the service-provider infrastructure to the other side of the customer network.
See the Layer 2
Protocol Tunneling figure in
Layer 2 Protocol Tunneling Overview,
with Customer X and Customer Y in access VLANs 30 and 40, respectively.
Asymmetric links connect the customers in Site 1 to edge
switches
in the service-provider network. The Layer 2 PDUs (for example, BPDUs) coming
into
Switch
B from Customer Y in Site 1 are forwarded to the infrastructure as
double-tagged packets with the well-known MAC address as the destination MAC
address. These double-tagged packets have the metro VLAN tag of 40, as well as
an inner VLAN tag (for example, VLAN 100). When the double-tagged packets enter
Switch
D, the outer VLAN tag 40 is removed, the well-known MAC address is replaced
with the respective Layer 2 protocol MAC address, and the packet is sent to
Customer Y on Site 2 as a single-tagged frame in VLAN 100.
You can also enable
Layer 2 protocol tunneling on access ports on the edge
switch
connected to access or trunk ports on the customer
switch.
In this case, the encapsulation and decapsulation process is the same as
described in the previous paragraph, except that the packets are not
double-tagged in the service-provider network. The single tag is the
customer-specific access VLAN tag.
In
switch
stacks, Layer 2 protocol tunneling configuration is distributed among all stack
members. Each stack member that receives an ingress packet on a local port
encapsulates or decapsulates the packet and forwards it to the appropriate
destination port. On a single
switch,
ingress Layer 2 protocol-tunneled traffic is sent across all local ports in the
same VLAN on which Layer 2 protocol tunneling is enabled. In a stack, packets
received by a Layer 2 protocol-tunneled port are distributed to all ports in
the stack that are configured for Layer 2 protocol tunneling and are in the
same VLAN. All Layer 2 protocol tunneling configuration is handled by the stack
master and distributed to all stack members.
Default Layer 2 Protocol Tunneling Configuration
The following table shows the default Layer 2 protocol tunneling configuration.
If a CoS value is configured on the interface, that value is used to set the BPDU CoS value for Layer 2 protocol tunneling.
If no CoS value is configured at the interface level, the default value for CoS marking of L2 protocol tunneling BPDUs is
5. This does not apply to data traffic.
How to Configure Tunneling
Configuring an IEEE
802.1Q Tunneling Port
SUMMARY STEPS
enable
configure terminal
interface interface-id
switchport access vlan vlan-id
switchport mode dot1q-tunnel
exit
vlan dot1q tag native
end
Use one of the
following:
show dot1q-tunnel
show running-config
interface
show vlan dot1q tag native
copy running-config
startup-config
DETAILED STEPS
Command or Action
Purpose
Step 1
enable
Example:
Switch> enable
Enables
privileged EXEC mode. Enter your password if prompted.
Step 2
configure terminal
Example:
Switch# configure terminal
Enters the global
configuration mode.
Step 3
interface interface-id
Example:
Switch(config)# interface gigabitethernet2/0/1
Enters interface
configuration mode for the interface to be configured as a tunnel port. This
should be the edge port in the service-provider network that connects to the
customer
switch. Valid interfaces include physical
interfaces and port-channel logical interfaces (port channels 1 to 48).
Step 4
switchport access vlan vlan-id
Example:
Switch(config-if)# switchport access vlan 2
Specifies the
default VLAN, which is used if the interface stops trunking. This VLAN ID is
specific to the particular customer.
Step 5
switchport mode dot1q-tunnel
Example:
Switch(config-if)# switchport mode dot1q-tunnel
Sets the
interface as an IEEE 802.1Q tunnel port.
Note
Use
the no switchport mode
dot1q-tunnel
interface configuration command to return the
port to the default state of dynamic desirable.
Step 6
exit
Example:
Switch(config-if)# exit
Returns to
privileged EXEC mode.
Step 7
vlan dot1q tag native
Example:
Switch(config)# vlan dot1q tag native
(Optional) Sets
the
switch to enable tagging of native VLAN
packets on all IEEE 802.1Q trunk ports. When not set, and a customer VLAN ID is
the same as the native VLAN, the trunk port does not apply a metro tag, and
packets could be sent to the wrong destination.
Note
Use
the no vlan dot1q tag
native global configuration command to disable tagging of native
VLAN packets.
Step 8
end
Example:
Switch(config)# end
Returns to
privileged EXEC mode.
Step 9
Use one of the
following:
show dot1q-tunnel
show running-config
interface
Example:
Switch# show dot1q-tunnel
or
Switch# show running-config interface
Displays the
ports configured for IEEE 802.1Q tunneling.
Displays the
ports that are in tunnel mode.
Step 10
show vlan dot1q tag native
Example:
Switch# show vlan dot1q native
Displays IEEE
802.1Q native VLAN tagging status.
Step 11
copy running-config
startup-config
Example:
Switch# copy running-config startup-config
(Optional) Saves your entries
in the configuration file.
Enables protocol
tunneling for the desired protocol. If no keyword is entered, tunneling is
enabled for all three Layer 2 protocols.
Note
Use
theno l2protocol-tunnel [cdp |
lldp |
point-to-point |
stp |
vtp ] interface configuration command to disable
protocol tunneling for one of the Layer 2 protocols or for all three.
(Optional)
Configures the threshold for packets-per-second accepted for encapsulation. The
interface is disabled if the configured threshold is exceeded. If no protocol
option is specified, the threshold applies to each of the tunneled Layer 2
protocol types. The range is 1 to 4096. The default is to have no threshold
configured.
Note
If you also
set a drop threshold on this interface, the
shutdown-threshold value must be greater than or
equal to the
drop-threshold value.
Note
Use the
no l2protocol-tunnel shutdown-threshold [
packet_second_rate_value |
cdp |
lldp |
point-to-point |
stp |
vtp ]
and the
no l2protocol-tunnel
drop-threshold [
packet_second_rate_value |
cdp |
lldp |
point-to-point |stp |
vtp ] commands to return the shutdown and drop
thresholds to the default settings.
(Optional)
Configures the threshold for packets-per-second accepted for encapsulation. The
interface drops packets if the configured threshold is exceeded. If no protocol
option is specified, the threshold applies to each of the tunneled Layer 2
protocol types. The range is 1 to 4096. The default is to have no threshold
configured.
Note
If you also
set a shutdown threshold on this interface, the
drop-threshold value must be less than or equal to
the
shutdown-threshold value.
Note
Use the
no l2protocol-tunnel shutdown-threshold [cdp |
lldp |
point-to-point |
stp |
vtp ]
and the
no l2protocol-tunnel
drop-threshold [cdp |
stp |
vtp ] commands to return the shutdown and drop
thresholds to the default settings.
Step 8
exit
Example:
Switch# exit
Returns to
global configuration mode.
Step 9
errdisable recovery cause l2ptguard
Example:
Switch(config)# errdisable recovery cause l2ptguard
(Optional)
Configures the recovery mechanism from a Layer 2 maximum-rate error so that the
interface is reenabled and can try again. Errdisable recovery is disabled by
default; when enabled, the default time interval is 300 seconds.
Step 10
l2protocol-tunnel cos
value
Example:
Switch(config)# l2protocol-tunnel cos value 7
(Optional)
Configures the CoS value for all tunneled Layer 2 PDUs. The range is 0 to 7;
the default is the default CoS value for the interface. If none is configured,
the default is 5.
Step 11
end
Example:
Switch(config)# end
Returns to
privileged EXEC mode.
Step 12
show l2protocol
Example:
Switch# show l2protocol
Displays the
Layer 2 tunnel ports on the
switch,
including the protocols configured, the thresholds, and the counters.
Step 13
copy running-config
startup-config
Example:
Switch# copy running-config startup-config
(Optional) Saves your entries
in the configuration file.
Configuring the SP
Edge Switch
Before you begin
For EtherChannels, you need
to configure both the SP (service-provider) edge
switches and the customer
switches for Layer 2 protocol tunneling.
(Optional)
Enables point-to-point protocol tunneling for the desired protocol. If no
keyword is entered, tunneling is enabled for all three protocols.
Note
To avoid a
network failure, make sure that the network is a point-to-point topology before
you enable tunneling for PAgP, LACP, or UDLD packets.
Note
Use the
no l2protocol-tunnel
[point-to-point
[pagp |
lacp |
udld ]]
interface configuration command to disable point-to-point
protocol tunneling for one of the Layer 2 protocols or for all three.
Step 6
l2protocol-tunnel
shutdown-threshold [point-to-point [pagp |
lacp |
udld ]]
value
(Optional)
Configures the threshold for packets-per-second accepted for encapsulation. The
interface is disabled if the configured threshold is exceeded. If no protocol
option is specified, the threshold applies to each of the tunneled Layer 2
protocol types. The range is 1 to 4096. The default is to have no threshold
configured.
Note
If you also
set a drop threshold on this interface, the
shutdown-threshold value must be greater than or
equal to the
drop-threshold value.
Note
Use the
no l2protocol-tunnel
shutdown-threshold [point-to-point [pagp |
lacp |
udld ]]
and the
no l2protocol-tunnel
drop-threshold [[point-to-point [pagp | lacp |
udld ]]
commands to return the shutdown and drop thresholds to
the default settings.
Step 7
l2protocol-tunnel
drop-threshold [point-to-point [pagp |
lacp |
udld ]]
value
(Optional)
Configures the threshold for packets-per-second accepted for encapsulation. The
interface drops packets if the configured threshold is exceeded. If no protocol
option is specified, the threshold applies to each of the tunneled Layer 2
protocol types. The range is 1 to 4096. The default is to have no threshold
configured.
Note
If you also
set a shutdown threshold on this interface, the
drop-threshold value must be less than or equal to
the
shutdown-threshold value.
Switch(config)# errdisable recovery cause l2ptguard
(Optional)
Configures the recovery mechanism from a Layer 2 maximum-rate error so that the
interface is reenabled and can try again. Errdisable recovery is disabled by
default; when enabled, the default time interval is 300 seconds.
Step 12
l2protocol-tunnel cos value
Example:
Switch(config)# l2protocol-tunnel cos 2
(Optional)
Configures the CoS value for all tunneled Layer 2 PDUs. The range is 0 to 7;
the default is the default CoS value for the interface. If none is configured,
the default is 5.
Step 13
end
Example:
Switch(config)# end
Returns to
privileged EXEC mode.
Step 14
show l2protocol
Example:
Switch)# show l2protocol
Displays the
Layer 2 tunnel ports on the
switch, including the protocols configured,
the thresholds, and the counters.
Step 15
copy running-config
startup-config
Example:
Switch# copy running-config startup-config
(Optional) Saves your entries
in the configuration file.
Configuring the
Customer
Switch
Before you begin
For EtherChannels,
you need to configure both the SP edge
switch
and the customer
switches
for Layer 2 protocol tunneling.
SUMMARY STEPS
enable
configure terminal
interface interface-id
switchport trunk encapsulation dot1q
switchport mode trunk
udld port
channel-group channel-group-number mode desirable
exit
interface port-channel port-channel
number
shutdown
no shutdown
end
show l2protocol
copy
running-config startup-config
DETAILED STEPS
Command or Action
Purpose
Step 1
enable
Example:
Switch> enable
Enables
privileged EXEC mode. Enter your password if prompted.
Step 2
configure terminal
Example:
Switch# configure terminal
Enters the global
configuration mode.
Step 3
interface interface-id
Example:
Switch(config)# interface gigabitethernet1/0/1
Specifies the
interface connected to the phone, and enters interface configuration mode.
Displays the
Layer 2 tunnel ports on the
switch, including the protocols configured,
the thresholds, and the counters.
Step 14
copy
running-config startup-config
Example:
Switch# copy running-config startup-config
(Optional) Saves
your entries in the configuration file.
Note
Use
the no switchport mode
trunk , the
no udld
enable , and the
no channel group
channel-group-number mode
desirable interface configuration commands to return the
interface to the default settings.
Configuration Examples for IEEE 802.1Q and Layer 2 Protocol Tunneling
Example: Configuring
an IEEE 802.1Q Tunneling Port
The following
example shows how to configure an interface as a tunnel port, enable tagging of
native VLAN packets, and verify the configuration. In this configuration, the VLAN ID
for the customer connected to Gigabit Ethernet interface 7 on stack member 1 is
VLAN 22.
Switch(config)# interface gigabitethernet1/0/7
Switch(config-if)# switchport access vlan 22
% Access VLAN does not exist. Creating vlan 22
Switch(config-if)# switchport mode dot1q-tunnel
Switch(config-if)# exit
Switch(config)# vlan dot1q tag native
Switch(config)# end
Switch# show dot1q-tunnel interface gigabitethernet1/0/7
Port
-----
Gi1/0/1Port
-----
Switch# show vlan dot1q tag native
dot1q native vlan tagging is enabled
Example: Configuring Layer 2 Protocol Tunneling
The following example shows how to configure Layer 2 protocol tunneling for CDP, STP, and VTP and to verify the configuration.
Examples: Configuring the SP Edge and Customer Switches
This example shows how to configure the SP edge switch 1 and edge switch 2. VLANs 17, 18, 19, and 20 are the access VLANs,
Fast Ethernet interfaces 1 and 2 are point-to-point tunnel ports with PAgP and UDLD enabled, the drop threshold is 1000, and
Fast Ethernet interface 3 is a trunk port.
This example shows how to configure the customer switch at Site 1. Fast Ethernet interfaces 1, 2, 3, and 4 are set for IEEE
802.1Q trunking, UDLD is enabled, EtherChannel group 1 is enabled, and the port channel is shut down and then enabled to activate
the EtherChannel configuration.