- Preface
- New and Changed Information for this Release
- Overview
- Configuring Fibre Channel Interfaces
- Configuring Fibre Channel Domain Parameters
- Configuring N Port Virtualization
- Configuring FCoE NPV
- Configuring VSAN Trunking
- Configuring SAN Port Channels
- Configuring and Managing VSANs
- Configuring and Managing Zones
- Distributing Device Alias Services
- Configuring Fibre Channel Routing Services and Protocols
- Managing FLOGI, Name Server, FDMI, and RSCN Databases
- Discovering SCSI Targets
- Advanced Fibre Channel Features
- Configuring FC-SP and DHCHAP
- Configuring Port Security
- Configuring Fabric Binding
- Configuring Fabric Configuration Servers
- Configuring Port Tracking
- Fibre Channel Slow Drain Device Detection and Congestion Avoidance- An Overview
- Index
- Information About Domain Parameters
- Fibre Channel Domains
- Domain Restarts
- Restarting a Domain
- Domain Manager Fast Restart
- Enabling Domain Manager Fast Restart
- Switch Priority
- Configuring Switch Priority
- About fcdomain Initiation
- Disabling or Reenabling fcdomains
- Configuring Fabric Names
- Incoming RCFs
- Rejecting Incoming RCFs
- Autoreconfiguring Merged Fabrics
- Enabling Autoreconfiguration
- Domain IDs
- Domain IDs - Guidelines
- Configuring Static or Preferred Domain IDs
- Allowed Domain ID Lists
- Configuring Allowed Domain ID Lists
- CFS Distribution of Allowed Domain ID Lists
- Enabling Distribution
- Locking the Fabric
- Committing Changes
- Discarding Changes
- Clearing a Fabric Lock
- Displaying CFS Distribution Status
- Displaying Pending Changes
- Displaying Session Status
- Contiguous Domain ID Assignments
- Enabling Contiguous Domain ID Assignments
- FC IDs
- Verifying the fcdomain Configuration
- Default Settings for Fibre Channel Domains
- Fibre Channel Domains
Configuring Fibre Channel Domain Parameters
This chapter describes how to configure Fibre Channel domain parameters.
This chapter includes the following sections:
Information About Domain Parameters
The Fibre Channel domain (fcdomain) feature performs principal switch selection, domain ID distribution, FC ID allocation, and fabric reconfiguration functions as described in the FC-SW-2 standards. The domains are configured on a per-VSAN basis. If you do not configure a domain ID, the local switch uses a random ID.
Caution | Changes to fcdomain parameters should not be performed on a daily basis. These changes should be made by an administrator or individual who is completely familiar with switch operations. |
When you change the configuration, be sure to save the running configuration. The next time you reboot the switch, the saved configuration is used. If you do not save the configuration, the previously saved startup configuration is used.
- Fibre Channel Domains
- Domain IDs
- FC IDs
- Verifying the fcdomain Configuration
- Default Settings for Fibre Channel Domains
Fibre Channel Domains
The fcdomain has four phases:
-
Principal switch selection—This phase guarantees the selection of a unique principal switch across the fabric.
-
Domain ID distribution—This phase guarantees that each switch in the fabric obtains a unique domain ID.
-
FC ID allocation—This phase guarantees a unique FC ID assignment to each device attached to the corresponding switch in the fabric.
-
Fabric reconfiguration—This phase guarantees a resynchronization of all switches in the fabric to ensure they simultaneously restart a new principal switch selection phase.
The following figure shows an example fcdomain configuration.
- Domain Restarts
- Restarting a Domain
- Domain Manager Fast Restart
- Enabling Domain Manager Fast Restart
- Switch Priority
- Configuring Switch Priority
- About fcdomain Initiation
- Disabling or Reenabling fcdomains
- Configuring Fabric Names
- Incoming RCFs
- Rejecting Incoming RCFs
- Autoreconfiguring Merged Fabrics
- Enabling Autoreconfiguration
Domain Restarts
Fibre Channel domains can be started disruptively or nondisruptively. If you perform a disruptive restart, reconfigure fabric (RCF) frames are sent to other switches in the fabric and data traffic is disrupted on all the switches in the VSAN (including remotely segmented ISLs). If you perform a nondisruptive restart, build fabric (BF) frames are sent to other switches in the fabric and data traffic is disrupted only on the switch.
If you are attempting to resolve a domain ID conflict, you must manually assign domain IDs. A disruptive restart is required to apply most configuration changes, including manually assigned domain IDs. Nondisruptive domain restarts are acceptable only when changing a preferred domain ID into a static one (and the actual domain ID remains the same).
Note | A static domain is specifically configured by the user and may be different from the runtime domain. If the domain IDs are different, the runtime domain ID changes to take on the static domain ID after the next restart, either disruptive or nondisruptive. |
If a VSAN is in interop mode, you cannot disruptively restart the fcdomain for that VSAN.
You can apply most of the configurations to their corresponding runtime values. Each of the following sections provide further details on how the fcdomain parameters are applied to the runtime values.
The fcdomain restart command applies your changes to the runtime settings. Use the disruptive option to apply most of the configurations to their corresponding runtime values, including preferred domain IDs.
Restarting a Domain
You can restart the fabric disruptively or nondisruptively.
1.
configure terminal
2.
fcdomain restart vsan
vsan-id
3.
switch(config)# fcdomain restart disruptive vsan
vsan-id
DETAILED STEPS
Domain Manager Fast Restart
When a principal link fails, the domain manager must select a new principal link. By default, the domain manager starts a build fabric (BF) phase, followed by a principal switch selection phase. Both of these phases involve all the switches in the VSAN, and together take at least 15 seconds to complete. To reduce the time required for the domain manager to select a new principal link, you can enable the domain manager fast restart feature.
When fast restart is enabled and a backup link is available, the domain manager needs only a few milliseconds to select a new principal link to replace the one that failed. Also, the reconfiguration required to select the new principal link only affects the two switches that are directly attached to the failed link, not the entire VSAN. When a backup link is not available, the domain manager reverts to the default behavior and starts a BF phase, followed by a principal switch selection phase. The fast restart feature can be used in any interoperability mode.
Enabling Domain Manager Fast Restart
You can enable the domain manager fast restart feature.
1.
configure terminal
2.
fcdomain optimize fast-restart vsan
vsan-id
3.
no fcdomain optimize fast-restart vsan
vsan-id
DETAILED STEPS
Switch Priority
By default, the configured priority is 128. The valid range to set the priority is between 1 and 254. Priority 1 has the highest priority. Value 255 is accepted from other switches, but cannot be locally configured.
Any new switch cannot become the principal switch when it joins a stable fabric. During the principal switch selection phase, the switch with the highest priority becomes the principal switch. If two switches have the same configured priority, the switch with the lower world-wide name (WWN) becomes the principal switch.
The priority configuration is applied to runtime when the fcdomain is restarted. This configuration is applicable to both disruptive and nondisruptive restarts.
Configuring Switch Priority
You can configure the priority for the principal switch.
1.
configure terminal
2.
fcdomain priority
number
vsan
vsan-id
3.
no fcdomain priority
number
vsan
vsan-id
DETAILED STEPS
About fcdomain Initiation
By default, the fcdomain feature is enabled on each switch. If you disable the fcdomain feature in a switch, that switch can no longer participate with other switches in the fabric. The fcdomain configuration is applied to runtime through a disruptive restart.
Disabling or Reenabling fcdomains
To disable or reenable fcdomains in a single VSAN or a range of VSANs, perform this task:
1. switch# configure terminal
2.
switch(config)# no fcdomain vsan
vsan-id
-
vsan-id
3.
switch(config)# fcdomain vsan
vsan-id
DETAILED STEPS
Command or Action | Purpose |
---|
Configuring Fabric Names
You can set the fabric name value for a disabled fcdomain.
1.
configure terminal
2.
fcdomain fabric-name 20:1:ac:16:5e:0:21:01 vsan
vsan-id
3.
no fcdomain fabric-name 20:1:ac:16:5e:0:21:01 vsan
vsan-id
DETAILED STEPS
Incoming RCFs
You can configure the rcf-reject option on a per-interface, per-VSAN basis. By default, the rcf-reject option is disabled (that is, RCF request frames are not automatically rejected).
The rcf-reject option takes effect immediately.
No fcdomain restart is required.
Note | You do not need to configure the RCF reject option on virtual Fibre Channel interfaces. |
Rejecting Incoming RCFs
You can reject incoming RCF request frames.
1.
configure terminal
2.
fcdomain rcf-reject vsan
vsan-id
3.
no fcdomain rcf-reject vsan
vsan-id
DETAILED STEPS
Autoreconfiguring Merged Fabrics
By default, the autoreconfigure option is disabled. When you join two switches belonging to two different stable fabrics that have overlapping domains, the following situations can occur:
-
If the autoreconfigure option is enabled on both switches, a disruptive reconfiguration phase is started.
-
If the autoreconfigure option is disabled on either or both switches, the links between the two switches become isolated.
The autoreconfigure option takes immediate effect at runtime. You do not need to restart the fcdomain. If a domain is currently isolated due to domain overlap, and you later enable the autoreconfigure option on both switches, the fabric continues to be isolated. If you enabled the autoreconfigure option on both switches before connecting the fabric, a disruptive reconfiguration (RCF) will occur. A disruptive reconfiguration can affect data traffic. You can nondisruptively reconfigure the fcdomain by changing the configured domains on the overlapping links and eliminating the domain overlap.
Enabling Autoreconfiguration
You can enable automatic reconfiguration in a specific VSAN (or range of VSANs).
1.
configure terminal
2.
fcdomain auto-reconfigure vsan
vsan-id
3.
no
fcdomain auto-reconfigure vsan
vsan-id
DETAILED STEPS
Domain IDs
Domain IDs uniquely identify a switch in a VSAN. A switch may have different domain IDs in different VSANs. The domain ID is part of the overall FC ID.
- Domain IDs - Guidelines
- Configuring Static or Preferred Domain IDs
- Allowed Domain ID Lists
- Configuring Allowed Domain ID Lists
- CFS Distribution of Allowed Domain ID Lists
- Enabling Distribution
- Locking the Fabric
- Committing Changes
- Discarding Changes
- Clearing a Fabric Lock
- Displaying CFS Distribution Status
- Displaying Pending Changes
- Displaying Session Status
- Contiguous Domain ID Assignments
- Enabling Contiguous Domain ID Assignments
Domain IDs - Guidelines
The configured domain ID can be preferred or static. By default, the configured domain ID is 0 (zero) and the configured type is preferred.
Note | The 0 (zero) value can be configured only if you use the preferred option. |
If you do not configure a domain ID, the local switch sends a random ID in its request. We recommend that you use static domain IDs.
When a subordinate switch requests a domain, the following process takes place (see the figure below):
-
The local switch sends a configured domain ID request to the principal switch.
-
The principal switch assigns the requested domain ID if available. Otherwise, it assigns another available domain ID.
The operation of a subordinate switch changes based on three factors:
-
The allowed domain ID lists
-
The configured domain ID
-
The domain ID that the principal switch has assigned to the requesting switch
In specific situations, the changes are as follows:
-
When the received domain ID is not within the allowed list, the requested domain ID becomes the runtime domain ID and all interfaces on that VSAN are isolated.
-
When the assigned and requested domain IDs are the same, the preferred and static options are not relevant, and the assigned domain ID becomes the runtime domain ID.
-
When the assigned and requested domain IDs are different, the following cases apply:
-
If the configured type is static, the assigned domain ID is discarded, all local interfaces are isolated, and the local switch assigns itself the configured domain ID, which becomes the runtime domain ID.
-
If the configured type is preferred, the local switch accepts the domain ID assigned by the principal switch and the assigned domain ID becomes the runtime domain ID.
-
If you change the configured domain ID, the change is only accepted if the new domain ID is included in all the allowed domain ID lists currently configured in the VSAN. Alternatively, you can also configure zero-preferred domain ID.
Caution | You must enter the fcdomain restart command if you want to apply the configured domain changes to the runtime domain. |
Note | If you have configured an allow domain ID list, the domain IDs that you add must be in that range for the VSAN. |
Configuring Static or Preferred Domain IDs
You can specify a static or preferred domain ID.
1.
configure terminal
2.
fcdomain domain
domain-id
static vsan
vsan-id
3.
no fcdomain domain
domain-id
static vsan
vsan-id
4.
fcdomain domain
domain-id
preferred
vsan
vsan-id
5.
no fcdomain domain
domain-id
preferred
vsan
vsan-id
DETAILED STEPS
Allowed Domain ID Lists
By default, the valid range for an assigned domain ID list is from 1 to 239. You can specify a list of ranges to be in the allowed domain ID list and separate each range with a comma. The principal switch assigns domain IDs that are available in the locally configured allowed domain list.
Use allowed domain ID lists to design your VSANs with nonoverlapping domain IDs. This helps you in the future if you need to implement IVR without the NAT feature.
If you configure an allowed list on one switch in the fabric, we recommend that you configure the same list in all other switches in the fabric to ensure consistency or use CFS to distribute the configuration.
Configuring Allowed Domain ID Lists
You can configure the allowed domain ID list.
1.
configure terminal
2.
fcdomain allowed
domain-id range
vsan
vsan-id
3.
no
fcdomain allowed
domain-id range
vsan
vsan-id
DETAILED STEPS
CFS Distribution of Allowed Domain ID Lists
You can enable the distribution of the allowed domain ID list configuration information to all Cisco SAN switches in the fabric using the Cisco Fabric Services (CFS) infrastructure. This feature allows you to synchronize the configuration across the fabric from the console of a single switch. Because the same configuration is distributed to the entire VSAN, you can avoid a possible misconfiguration and the possibility that two switches in the same VSAN have configured incompatible allowed domains.
Use CFS to distribute the allowed domain ID list to ensure consistency in the allowed domain ID lists on all switches in the VSAN.
Note | We recommend configuring the allowed domain ID list and committing it on the principal switch. |
For additional information, refer to Using Cisco Fabric Services in the System Management Configuration Guide for your device.
Enabling Distribution
You can enable (or disable) allowed domain ID list configuration distribution.
CFS distribution of allowed domain ID lists is disabled by default. You must enable distribution on all switches to which you want to distribute the allowed domain ID lists.
1.
configure terminal
2.
fcdomain distribute
3.
no fcdomain distribute
DETAILED STEPS
Locking the Fabric
The first action that modifies the existing configuration creates the pending configuration and locks the feature in the fabric. After you lock the fabric, the following conditions apply:
-
No other user can make any configuration changes to this feature.
-
A pending configuration is created by copying the active configuration. Subsequent modifications are made to the pending configuration and remain there until you commit the changes to the active configuration (and other switches in the fabric) or discard them.
Committing Changes
You can commit pending domain configuration changes and release the lock.
To apply the pending domain configuration changes to other SAN switches in the VSAN, you must commit the changes. The pending configuration changes are distributed and, on a successful commit, the configuration changes are applied to the active configuration in the SAN switches throughout the VSAN and the fabric lock is released.
1.
configure terminal
2.
fcdomain commit vsan
vsan-id
DETAILED STEPS
Command or Action | Purpose |
---|
Discarding Changes
You can discard pending domain configuration changes and release the lock.
At any time, you can discard the pending changes to the domain configuration and release the fabric lock. If you discard (abort) the pending changes, the configuration remains unaffected and the lock is released.
1.
configure terminal
2.
fcdomain abort vsan
vsan-id
DETAILED STEPS
Command or Action | Purpose |
---|
Clearing a Fabric Lock
If you have performed a domain configuration task and have not released the lock by either committing or discarding the changes, an administrator can release the lock from any switch in the fabric. If the administrator performs this task, your pending changes are discarded and the fabric lock is released.
The pending changes are only available in the volatile directory and are discarded if the switch is restarted.
To release a fabric lock, enter the clear fcdomain session vsan command in EXEC mode using a login ID that has administrative privileges:
switch# clear fcdomain session vsan 10
Displaying CFS Distribution Status
You can display the status of CFS distribution for allowed domain ID lists by using the show fcdomain status command:
switch# show fcdomain status
CFS distribution is enabled
Displaying Pending Changes
You can display the pending configuration changes by using the show fcdomain pending command:
switch# show fcdomain pending vsan 10
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
You can display the differences between the pending configuration and the current configuration by using the show fcdomain pending-diff command:
switch# show fcdomain pending-diff vsan 10
Current Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 24,100.
[User] configured allowed domain IDs: 1-239.
Pending Configured Allowed Domains
----------------------------------
VSAN 10
Assigned or unallowed domain IDs: 1-9,24,100,231-239.
[User] configured allowed domain IDs: 10-230.
Displaying Session Status
You can display the status of the distribution session by using the show fcdomain session-status vsan command:
switch# show fcdomain session-status vsan 1
Last Action: Distribution Enable
Result: Success
Contiguous Domain ID Assignments
By default, the contiguous domain assignment is disabled. When a subordinate switch requests the principal switch for two or more domains and the domains are not contiguous, the following situations can occur:
-
If the contiguous domain assignment is enabled in the principal switch, the principal switch locates contiguous domains and assigns them to the subordinate switches. If contiguous domains are not available, the switch software rejects this request.
-
If the contiguous domain assignment is disabled in the principal switch, the principal switch assigns the available domains to the subordinate switch.
Enabling Contiguous Domain ID Assignments
You can enable contiguous domains in a specific VSAN (or a range of VSANs).
1.
configure terminal
2.
fcdomain contiguous-allocation vsan
vsan-id
-
vsan-id
3.
no fcdomain contiguous-allocation vsan
vsan-id
DETAILED STEPS
FC IDs
When an N port logs into a SAN switch, it is assigned an FC ID. By default, the persistent FC ID feature is enabled. If this feature is disabled, the following situations can occur:
-
An N port logs into a SAN switch. The WWN of the requesting N port and the assigned FC ID are retained and stored in a volatile cache. The contents of this volatile cache are not saved across reboots.
-
The switch is designed to preserve the binding FC ID to the WWN on a best-effort basis. For example, if one N port disconnects from the switch and its FC ID is requested by another device, this request is granted and the WWN with the initial FC ID association is released.
-
The volatile cache stores up to 4000 entries of WWN to FC ID binding. If this cache is full, a new (more recent) entry overwrites the oldest entry in the cache. In this case, the corresponding WWN to FC ID association for the oldest entry is lost.
-
N ports receive the same FC IDs if disconnected and reconnected to any port within the same switch (as long as it belongs to the same VSAN).
- Persistent FC IDs
- Enabling the Persistent FC ID Feature
- Persistent FC ID Configuration Guidelines
- Configuring Persistent FC IDs
- Unique Area FC IDs for HBAs
- Configuring Unique Area FC IDs for an HBA
- Persistent FC ID Selective Purging
- Purging Persistent FC IDs
Persistent FC IDs
When persistent FC IDs are enabled, the following occurs:
-
The current FC IDs in use in the fcdomain are saved across reboots.
-
The fcdomain automatically populates the database with dynamic entries that the switch has learned about after a device (host or disk) is plugged into a port interface.
Note | If you connect to the switch from an AIX or HP-UX host, be sure to enable the persistent FC ID feature in the VSAN that connects these hosts. |
Note | When persistent FC IDs are enabled, FC IDs cannot be changed after a reboot. FC IDs are enabled by default, but can be disabled for each VSAN. |
A persistent FC ID assigned to an F port can be moved across interfaces and can continue to maintain the same persistent FC ID.
Enabling the Persistent FC ID Feature
You can enable the persistent FC ID feature.
1.
configure terminal
2.
fcdomain fcid persistent vsan
vsan-id
3.
no fcdomain fcid persistent vsan
vsan-id
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. |
Step 2 |
fcdomain fcid persistent vsan
vsan-id
Example: switch(config)# fcdomain fcid persistent vsan 78 |
Activates (default) persistency of FC IDs in the specified VSAN. |
Step 3 |
no fcdomain fcid persistent vsan
vsan-id
Example: switch(config)# no fcdomain fcid persistent vsan 33 |
Disables the FC ID persistency feature in the specified VSAN. |
Persistent FC ID Configuration Guidelines
When the persistent FC ID feature is enabled, you can enter the persistent FC ID submode and add static or dynamic entries in the FC ID database. By default, all added entries are static. Persistent FC IDs are configured on a per-VSAN basis.
When manually configuring a persistent FC ID, follow these requirements:
-
Ensure that the persistent FC ID feature is enabled in the required VSAN.
-
Ensure that the required VSAN is an active VSAN. Persistent FC IDs can only be configured on active VSANs.
-
Verify that the domain part of the FC ID is the same as the runtime domain ID in the required VSAN. If the software detects a domain mismatch, the command is rejected.
-
Verify that the port field of the FC ID is 0 (zero) when configuring an area.
Configuring Persistent FC IDs
You can configure persistent FC IDs.
1.
configure terminal
2.
fcdomain fcid database
3.
vsan
vsan-id
wwn 33:e8:00:05:30:00:16:df fcid
fcid
4.
vsan
vsan-id
wwn 11:22:11:22:33:44:33:44 fcid
fcid
dynamic
5.
vsan
vsan-id
wwn 11:22:11:22:33:44:33:44 fcid
fcid
area
DETAILED STEPS
Command or Action | Purpose | |||
---|---|---|---|---|
Step 1 | configure terminal
Example: switch# configure terminal switch(config)# |
Enters global configuration mode. | ||
Step 2 |
fcdomain fcid database
Example: switch(config)# fcdomain fcid database |
Enters FC ID database configuration submode. | ||
Step 3 |
vsan
vsan-id
wwn 33:e8:00:05:30:00:16:df fcid
fcid
Example: switch(config-fcid-db)# vsan 26 wwn 33:e8:00:05:30:00:16:df fcid 4 |
Configures a device WWN (33:e8:00:05:30:00:16:df) with the FC ID 0x070128 in the specified VSAN.
| ||
Step 4 |
vsan
vsan-id
wwn 11:22:11:22:33:44:33:44 fcid
fcid
dynamic
Example: switch(config-fcid-db)# vsan 13 wwn 11:22:11:22:33:44:33:44 fcid 6 dynamic |
Configures a device WWN (11:22:11:22:33:44:33:44) with the FC ID 0x070123 in the specified VSAN in dynamic mode. | ||
Step 5 |
vsan
vsan-id
wwn 11:22:11:22:33:44:33:44 fcid
fcid
area
Example: switch(config-fcid-db)# vsan 88 wwn 11:22:11:22:33:44:33:44 fcid 4 area |
Configures a device WWN (11:22:11:22:33:44:33:44) with the FC IDs 0x070100 through 0x701FF in the specified VSAN.
|
Unique Area FC IDs for HBAs
Note | Read this section only if the Host Bus Adapter (HBA) port and the storage port are connected to the same switch. |
Some HBA ports require a different area ID than for the storage ports when they are both connected to the same switch. For example, if the storage port FC ID is 0x6f7704, the area for this port is 77. In this case, the HBA port’s area can be anything other than 77. The HBA port’s FC ID must be manually configured to be different from the storage port’s FC ID.
Cisco SAN switches facilitate this requirement with the FC ID persistence feature. You can use this feature to preassign an FC ID with a different area to either the storage port or the HBA port.
Configuring Unique Area FC IDs for an HBA
You can configure a different area ID for the HBA port.
The following task uses an example configuration with a switch domain of 111(6f hex). The server connects to the switch over FCoE. The HBA port connects to interface vfc20 and the storage port connects to interface fc2/3 on the same switch.
Step 1 |
Obtain the port WWN (Port Name field) ID of the HBA using the show flogi database command.
switch# show flogi database ----------------------------------------------------------------- INTERFACE VSAN FCID PORT NAME NODE NAME ------------------------------------------------------------------ vfc20 3 0x6f7703 50:05:08:b2:00:71:c8:c2 50:05:08:b2:00:71:c8:c0 fc2/3 3 0x6f7704 50:06:0e:80:03:29:61:0f 50:06:0e:80:03:29:61:0f
| ||
Step 2 |
Shut down the HBA interface in the
SAN switch.
switch# configure terminal switch(config)# interface vfc 20 switch(config-if)# shutdown switch(config-if)# end | ||
Step 3 |
Verify that the FC ID feature is enabled using the show fcdomain vsan command.
switch# show fcdomain vsan 1 ... Local switch configuration information: State: Enabled FCID persistence: Disabled If this feature is disabled, continue to the next step to enable the persistent FC ID. If this feature is already enabled, skip to the following step. | ||
Step 4 |
Enable the persistent FC ID feature in the
SAN switch.
switch# configure terminal switch(config)# fcdomain fcid persistent vsan 1 switch(config)# end | ||
Step 5 |
Assign a new FC ID with a different area allocation. In this example, replace 77 with ee.
switch# configure terminal switch(config)# fcdomain fcid database switch(config-fcid-db)# vsan 3 wwn 50:05:08:b2:00:71:c8:c2 fcid 0x6fee00 area | ||
Step 6 |
Enable the HBA interface in the
SAN switch.
switch# configure terminal switch(config)# interface vfc 20 switch(config-if)# no shutdown switch(config-if)# end | ||
Step 7 |
Verify the pWWN ID of the HBA by using the show flogi database command.
switch# show flogi database ------------------------------------------------------------------ INTERFACE VSAN FCID PORT NAME NODE NAME ------------------------------------------------------------------ vfc20 3 0x6fee00 50:05:08:b2:00:71:c8:c2 50:05:08:b2:00:71:c8:c0 fc2/3 3 0x6f7704 50:06:0e:80:03:29:61:0f 50:06:0e:80:03:29:61:0f
|
Persistent FC ID Selective Purging
Persistent FC IDs can be purged selectively. Static entries and FC IDs currently in use cannot be deleted. The table below identifies the FC ID entries that are deleted or retained when persistent FC IDs are purged.
Persistent FC ID state |
Persistent Usage State |
Action |
---|---|---|
Static |
In use |
Not deleted |
Static |
Not in use |
Not deleted |
Dynamic |
In use |
Not deleted |
Dynamic |
Not in use |
Deleted |
Purging Persistent FC IDs
You can purge persistent FC IDs.
1.
purge fcdomain fcid vsan
vsan-id
2.
purge fcdomain fcid vsan
vsan-id
-
vsan-id
DETAILED STEPS
Command or Action | Purpose | |
---|---|---|
Step 1 |
purge fcdomain fcid vsan
vsan-id
Example: switch# purge fcdomain fcid vsan 667 |
Purges all dynamic and unused FC IDs in the specified VSAN. |
Step 2 |
purge fcdomain fcid vsan
vsan-id
-
vsan-id
Example: switch# purge fcdomain fcid vsan 50-100 |
Purges dynamic and unused FC IDs in the specified VSAN range. |
Verifying the fcdomain Configuration
Note | If the fcdomain feature is disabled, the runtime fabric name in the display is the same as the configured fabric name. |
This example shows how to display information about fcdomain configurations:
switch# show fcdomain vsan 2
Use the show fcdomain domain-list command to display the list of domain IDs of all switches belonging to a specified VSAN. This list provides the WWN of the switches owning each domain ID. The next example uses the following values:
-
A switch with WWN of 20:01:00:05:30:00:47:df is the principal switch and has domain 200.
-
A switch with WWN of 20:01:00:0d:ec:08:60:c1 is the local switch (the one where you typed the CLI command to show the domain-list) and has domain 99.
-
The IVR manager obtained virtual domain 97 using 20:01:00:05:30:00:47:df as the WWN for a virtual switch.
switch# show fcdomain domain-list vsan 76
Number of domains: 3
Domain ID WWN
--------- -----------------------
0xc8(200) 20:01:00:05:30:00:47:df [Principal]
0x63(99) 20:01:00:0d:ec:08:60:c1 [Local]
0x61(97) 50:00:53:0f:ff:f0:10:06 [Virtual (IVR)]
Use the show fcdomain allowed vsan command to display the list of allowed domain IDs configured on this switch..
switch# show fcdomain allowed vsan 1
Assigned or unallowed domain IDs: 1-96,100,111-239.
[Interoperability Mode 1] allowed domain IDs: 97-127.
[User] configured allowed domain IDs: 50-110.
Ensure that the requested domain ID passes the switch software checks, if interop 1 mode is required in this switch.
The following example shows how to display all existing, persistent FC IDs for a specified VSAN. You can also specify the unused option to view only persistent FC IDs that are still not in use.
switch# show fcdomain fcid persistent vsan 1000
The following example shows how to display frame and other fcdomain statistics for a specified VSAN or SAN port channel:
switch# show fcdomain statistics vsan 1
VSAN Statistics
Number of Principal Switch Selections: 5
Number of times Local Switch was Principal: 0
Number of 'Build Fabric's: 3
Number of 'Fabric Reconfigurations': 0
The following example shows how to display FC ID allocation statistics including a list of assigned and free FC IDs:
switch# show fcdomain address-allocation vsan 1
The following example shows how to display the valid address allocation cache. The cache is used by the principal switch to reassign the FC IDs for a device (disk or host) that exited and reentered the fabric. In the cache content, VSAN refers to the VSAN that contains the device, WWN refers to the device that owned the FC IDs, and mask refers to a single or entire area of FC IDs.
switch# show fcdomain address-allocation cache
Default Settings for Fibre Channel Domains
The following table lists the default settings for all fcdomain parameters.
Parameters |
Default |
---|---|
fcdomain feature |
Enabled |
Configured domain ID |
0 (zero) |
Configured domain |
Preferred |
auto-reconfigure option |
Disabled |
contiguous-allocation option |
Disabled |
Priority |
128 |
Allowed list |
1 to 239 |
Fabric name |
20:01:00:05:30:00:28:df |
rcf-reject |
Disabled |
Persistent FC ID |
Enabled |
Allowed domain ID list configuration distribution |
Disabled |