Server Specifications
This appendix lists the physical, environmental, and power specifications for the server.
Physical Specifications
The following table lists the physical specifications for the server versions.
Description |
Specification |
Height |
1.7 in. (43.2 mm) |
Width |
16.9 in. (429.0 mm) |
Depth (length) |
Server only: 29.5 in. (740.3 mm) Server with slide rail: 31.0 in (787.4 mm) |
Weight |
Maximum: 37.5 lb. (17.0 Kg) Minimum: 29.0 lb. (13.2 Kg) |
Environmental Specifications
The following table lists the environmental requirements and specifications for the server.
Description |
Specification |
||
Temperature, Operating |
10° C to 35° C (50° F to 95° F) with no direct sunlight Derate the maximum temperature by 1°C per every 300 meters of altitude above sea level.
|
||
Temperature, non-operating (when the server is stored or transported) |
Below -40° C or above 65° C (below -40° F or above 149° F) Maximum rate of change (operating and non-operating) 20° C/hr (36° F/hr) |
||
Extended Operating Temperature |
5° C to 40° C (41° F to 104° F) with no direct sunlight Maximum allowable operating temperature derated 1° C/175 m (1° F/319 ft) above 950 m (3117 ft) 5° C to 45° C (41° F to 113° F) with no direct sunlight Maximum allowable operating temperature derated 1° C/125 m (1° F/228 ft) above 950 m (3117 ft) System performance may be impacted when operating in the extended operating temperature range. Operation above 40° C is limited to less than 1% of annual operating hours. Hardware configuration limits apply to extended operating temperature range. |
||
Humidity (RH), operating |
8 to 90% and 24° C (75o F) maximum dew-point temperature, non-condensing environment |
||
Humidity (RH), non-operating (when the server is stored or transported) |
Below 5% or above 95% and 33o C (91o F) maximum dew-point temperature, non-condensing environment |
||
Altitude, operating |
0 to 10,000 feet |
||
Altitude, non-operating (when the server is stored or transported) |
0 to 40,000 feet |
||
Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.8 |
||
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
43 |
Network Interface Card Considerations
This section describes network interface card (NIC) support and considerations for Cisco Application Policy Infrastructure Controller (APIC) APIC M4/L4.
The following supported network interface cards must be inserted to PCIe Riser 01 for Cisco APIC M4/L4.
-
APIC-P-I8D25GF (2 x 10/25G SFP28)
-
APIC-P-ID10GC (2 x 10GBase-T)
-
APIC-PCIE-C25Q-04 (4 × 10/25G SFP28)
The following virtual interface cards are also supported:
-
Cisco VIC 1455 (4 × 10/25G SFP28)
The supported network interface cards have following considerations:
-
10/25GbE ports on Cisco VIC 1455 and APIC-P-I8D25GF can be used as either 10G or 25G ports. All ports must have the same speed.
-
25G connectivity between Cisco Application Centric Infrastructure (ACI) leaf and Cisco APIC M4/L4 must use copper cable when APIC-P-I8D25GF network interface cards are used. For example, Cisco SFP-H25G-CU1M.
-
25G connectivity between the Cisco ACI leaf and Cisco APIC M4/L4 can use either copper or fiber cables when APIC-PCIE-C25Q-04/Cisco VIC 1455 network interface cards are used.
Please see the list of transceiver options: https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/transceiver-modules/datasheet-c78-736950.html.
-
APIC-P-ID10GC supports 10G Base-T connectivity to Cisco APIC leaf nodes.
-
The Cisco VIC 1455 has 4 ports: port-4, port-3, port-2, and port-1, from left to right.
-
Given that the port channel is enabled:
-
Only two vNICs and vHBAs are available for use.
-
Port 0 and 1 are bundled as one port channel and port 2 and 3 are bundled as the other port channel.
-
-
Port 1 and port 2 is one pair, corresponding to eth2-1 on Cisco APIC. Port 3 and port 4 is another pair, corresponding to eth2-2 on Cisco APIC. Only one connection is allowed for each pair. For example, you can connect one cable to either port 1 or port 2, and you can connect another one cable to either port 3 or port 4. Do not connect two cables on any pair.
-
See NIC Mode and NIC Redundancy Settings for additional considerations and more information on NIC modes.
Power Specifications
System Workload Factor |
50% |
75% |
100% |
---|---|---|---|
Maximum Input Power |
409.91 W |
409.91 W |
409.91 W |
Input Power |
268.24 W |
338.59 W |
409.91 W |
Idle Input Power |
129.18 W |
129.18 W |
129.18 W |
Input Current |
1.13 A |
1.43 A |
1.72 A |
Air Flow |
31.69 cfm |
40 cfm |
48.43 cfm |
Cooling |
915.28 BTU/hr. |
1155.31 BTU/hr. |
1398.68 BTU/hr. |
System Workload Factor |
50% |
75% |
100% |
---|---|---|---|
Maximum Input Power |
429.85 W |
429.85 W |
429.85 W |
Input Power |
280.83 W |
355 W |
429.85 W |
Idle Input Power |
134.26 W |
134.26 W |
134.26 W |
Input Current |
1.19 A |
1.5 A |
1.81 A |
Air Flow |
33.18 cfm |
41.94 cfm |
50.78 cfm |
Cooling |
958.22 BTU/hr. |
1211.31 BTU/hr. |
1466.71 BTU/hr. |
![]() Note |
Do not mix power supply types or wattages in the server. Both power supplies must be identical. |
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
1600 W AC Power Supply
This section lists the specifications for each 1600 W AC power supply (Cisco part number APIC-PSU1-1600W).
Description |
Specification |
AC Input Voltage |
Nominal range: 200–240 VAC (Range: 180–264 VAC) |
AC Input Frequency |
Nominal range: 50 to 60Hz (Range: 47–63 Hz) |
Maximum AC Input current |
9.5 A at 200 VAC |
Maximum input volt-amperes |
1250 VA at 200 VAC |
Maximum inrush current |
30 A 35° C |
Maximum hold-up time |
80 ms at 1600 W |
Maximum output power per PSU |
1600 W at 200-240 VAC |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
Climate Savers Platinum Efficiency (80Plus Platinum certified) |
Form factor |
RSP2 |
Input connector |
IEC320 C14 |
1050 W DC Power Supply
This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV2-1050DC).
Description |
Specification |
DC Input Voltage |
Nominal range: -48 to -60 VDC (Range: -40 to -72 VDC) |
Maximum DC input current |
32 A at -40 VDC |
Maximum input wattage |
1234 W |
Maximum inrush current |
35 A (sub-cycle duration) |
Maximum hold-up time |
5 ms at 100% load (1050 W main and 36 W standby) |
Maximum output power per PSU |
1050 W on 12 VDC main power 36 W on 12 VDC standby power |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
≥ 92% at 50% load |
Form factor |
RSP2 |
Input connector |
Fixed 3-wire block |
Power Cord Specifications
Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.
![]() Note |
Only the approved power cords or jumper power cords listed below are supported. |
Description |
Length (Feet) |
Length (Meters) |
CAB-48DC-40A-8AWG DC power cord, -48 VDC, 40 A, 8 AWG Three-socket Mini-Fit connector to three-wire |
11.7 |
3.5 |
CAB-C13-C14-AC AC power cord, 10 A; C13 to C14, recessed receptacle |
9.8 |
3.0 |
CAB-250V-10A-AR AC power cord, 250 V, 10 A Argentina |
8.2 |
2.5 |
CAB-C13-C14-2M-JP AC Power Cord, C13 to C14 Japan PSE Mark |
6.6 |
2.0 |
CAB-9K10A-EU AC Power Cord, 250 V, 10 A; CEE 7/7 Plug Europe |
8.2 |
2.5 |
CAB-250V-10A-IS AC Power Cord, 250 V, 10 A Israel |
8.2 |
2.5 |
CAB-250V-10A-CN AC power cord, 250 V, 10 A PR China |
8.2 |
2.5 |
CAB-ACTW AC power cord, 250 V, 10 A Taiwan |
7.5 |
2.3 |
CAB-C13-CBN AC cabinet jumper power cord, 250, 10 A, C13 to C14 |
2.2 |
0.68 |
CAB-C13-C14-2M AC cabinet jumper power cord, 250 V, 10 A, C13 to C14 |
6.6 |
2.0 |
CAB-9K10A-AU AC power cord, 250 V, 10 A, 3112 plug, Australia |
8.2 |
2.5 |
CAB-N5K6A-NA AC power cord, 200/240 V, 6 A, North America |
8.2 |
2.5 |
CAB-250V-10A-ID AC power Cord, 250 V, 10 A, India |
8.2 |
2.5 |
CAB-9K10A-SW AC power cord, 250 V, 10 A, MP232 plug Switzerland |
8.2 |
2.5 |
CAB-250V-10A-BR AC power Cord, 250 V, 10 A Brazil |
8.2 |
2.5 |
CAB-9K10A-UK AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug United Kingdom |
8.2 |
2.5 |
CAB-9K12A-NA AC power cord, 125 V, 13 A, NEMA 5-15 plug North America |
8.2 |
2.5 |
CAB-AC-L620-C13 AC power cord, NEMA L6-20 to C13 connectors |
6.6 |
2.0 |
CAB-9K10A-IT AC power cord, 250 V, 10 A, CEI 23-16/VII plug Italy |
8.2 |
2.5 |
R2XX-DMYMPWRCORD No power cord; PID option for ordering server with no power cord |
NA |
NA |