Server Specifications

Server Specifications

This appendix lists the physical, environmental, and power specifications for the server.

Physical Specifications

The following table lists the physical specifications for the server versions.

Table 1. Physical Specifications

Description

Specification

Height

1.7 in. (43.2 mm)

Width

16.9 in. (429.0 mm)

Depth (length)

Server only: 29.5 in. (740.3 mm)

Server with slide rail: 31.0 in (787.4 mm)

Weight

Maximum: 37.5 lb. (17.0 Kg)

Minimum: 29.0 lb. (13.2 Kg)

Environmental Specifications

The following table lists the environmental requirements and specifications for the server.

Table 2. Physical Specifications

Description

Specification

Temperature, Operating

10° C to 35° C (50° F to 95° F) with no direct sunlight

Derate the maximum temperature by 1°C per every 300 meters of altitude above sea level.

Note

 

Although the ASHRAE guidelines define multiple classes with different operating ranges, the recommended temperature and humidity operating range is the same for each class. The recommended temperature and humidity ranges are:

  • Operating Temperature: 64.4°F to 80.6°F (18°C to 27°C)

For general information, see the Cisco Unified Computing System Site Planning Guide: Data Center Power and Cooling.

Temperature, non-operating

(when the server is stored or transported)

Below -40° C or above 65° C (below -40° F or above 149° F)

Maximum rate of change (operating and non-operating) 20° C/hr (36° F/hr)

Extended Operating Temperature

5° C to 40° C (41° F to 104° F) with no direct sunlight

Maximum allowable operating temperature derated

1° C/175 m (1° F/319 ft) above 950 m (3117 ft)

5° C to 45° C (41° F to 113° F) with no direct sunlight

Maximum allowable operating temperature derated

1° C/125 m (1° F/228 ft) above 950 m (3117 ft)

System performance may be impacted when operating in the

extended operating temperature range.

Operation above 40° C is limited to less than 1% of annual

operating hours.

Hardware configuration limits apply to extended operating temperature range.

Humidity (RH), operating

8 to 90% and 24° C (75o F) maximum dew-point temperature, non-condensing environment

Humidity (RH), non-operating

(when the server is stored or transported)

Below 5% or above 95% and 33o C (91o F) maximum dew-point temperature, non-condensing environment

Altitude, operating

0 to 10,000 feet

Altitude, non-operating

(when the server is stored or transported)

0 to 40,000 feet

Sound power level

Measure A-weighted per ISO7779 LwAd (Bels)

Operation at 73°F (23°C)

5.8

Sound pressure level

Measure A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

43

Network Interface Card Considerations

This section describes network interface card (NIC) support and considerations for Cisco Application Policy Infrastructure Controller (APIC) APIC M4/L4.

The following supported network interface cards must be inserted to PCIe Riser 01 for Cisco APIC M4/L4.

  • APIC-P-I8D25GF (2 x 10/25G SFP28)

  • APIC-P-ID10GC (2 x 10GBase-T)

  • APIC-PCIE-C25Q-04 (4 × 10/25G SFP28)

The following virtual interface cards are also supported:

  • Cisco VIC 1455 (4 × 10/25G SFP28)

The supported network interface cards have following considerations:

  • 10/25GbE ports on Cisco VIC 1455 and APIC-P-I8D25GF can be used as either 10G or 25G ports. All ports must have the same speed.

  • 25G connectivity between Cisco Application Centric Infrastructure (ACI) leaf and Cisco APIC M4/L4 must use copper cable when APIC-P-I8D25GF network interface cards are used. For example, Cisco SFP-H25G-CU1M.

  • 25G connectivity between the Cisco ACI leaf and Cisco APIC M4/L4 can use either copper or fiber cables when APIC-PCIE-C25Q-04/Cisco VIC 1455 network interface cards are used.

    Please see the list of transceiver options: https://www.cisco.com/c/en/us/products/collateral/interfaces-modules/transceiver-modules/datasheet-c78-736950.html.

  • APIC-P-ID10GC supports 10G Base-T connectivity to Cisco APIC leaf nodes.

  • The Cisco VIC 1455 has 4 ports: port-4, port-3, port-2, and port-1, from left to right.

    • Given that the port channel is enabled:

      • Only two vNICs and vHBAs are available for use.

      • Port 0 and 1 are bundled as one port channel and port 2 and 3 are bundled as the other port channel.

    • Port 1 and port 2 is one pair, corresponding to eth2-1 on Cisco APIC. Port 3 and port 4 is another pair, corresponding to eth2-2 on Cisco APIC. Only one connection is allowed for each pair. For example, you can connect one cable to either port 1 or port 2, and you can connect another one cable to either port 3 or port 4. Do not connect two cables on any pair.

See NIC Mode and NIC Redundancy Settings for additional considerations and more information on NIC modes.

Power Specifications

Table 3. M4 System Load Estimates

System Workload Factor

50%

75%

100%

Maximum Input Power

409.91 W

409.91 W

409.91 W

Input Power

268.24 W

338.59 W

409.91 W

Idle Input Power

129.18 W

129.18 W

129.18 W

Input Current

1.13 A

1.43 A

1.72 A

Air Flow

31.69 cfm

40 cfm

48.43 cfm

Cooling

915.28 BTU/hr.

1155.31 BTU/hr.

1398.68 BTU/hr.

Table 4. L4 System Load Estimates

System Workload Factor

50%

75%

100%

Maximum Input Power

429.85 W

429.85 W

429.85 W

Input Power

280.83 W

355 W

429.85 W

Idle Input Power

134.26 W

134.26 W

134.26 W

Input Current

1.19 A

1.5 A

1.81 A

Air Flow

33.18 cfm

41.94 cfm

50.78 cfm

Cooling

958.22 BTU/hr.

1211.31 BTU/hr.

1466.71 BTU/hr.


Note


Do not mix power supply types or wattages in the server. Both power supplies must be identical.

You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:

http://ucspowercalc.cisco.com

The power specifications for the supported power supply options are listed in the following sections.

1600 W AC Power Supply

This section lists the specifications for each 1600 W AC power supply (Cisco part number APIC-PSU1-1600W).

Table 5. 1600 W AC Specifications

Description

Specification

AC Input Voltage

Nominal range: 200–240 VAC

(Range: 180–264 VAC)

AC Input Frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC Input current

9.5 A at 200 VAC

Maximum input volt-amperes

1250 VA at 200 VAC

Maximum inrush current

30 A 35° C

Maximum hold-up time

80 ms at 1600 W

Maximum output power per PSU

1600 W at 200-240 VAC

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP2

Input connector

IEC320 C14

1050 W DC Power Supply

This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV2-1050DC).

Table 6. 1050 W DC Specifications

Description

Specification

DC Input Voltage

Nominal range: -48 to -60 VDC

(Range: -40 to -72 VDC)

Maximum DC input current

32 A at -40 VDC

Maximum input wattage

1234 W

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

5 ms at 100% load (1050 W main and 36 W standby)

Maximum output power per PSU

1050 W on 12 VDC main power

36 W on 12 VDC standby power

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

≥ 92% at 50% load

Form factor

RSP2

Input connector

Fixed 3-wire block

Power Cord Specifications

Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.


Note


Only the approved power cords or jumper power cords listed below are supported.


Table 7. Supported Power Cords

Description

Length (Feet)

Length (Meters)

CAB-48DC-40A-8AWG

DC power cord, -48 VDC, 40 A, 8 AWG

Three-socket Mini-Fit connector to three-wire

11.7

3.5

CAB-C13-C14-AC

AC power cord, 10 A; C13 to C14, recessed receptacle

9.8

3.0

CAB-250V-10A-AR

AC power cord, 250 V, 10 A

Argentina

8.2

2.5

CAB-C13-C14-2M-JP

AC Power Cord, C13 to C14

Japan PSE Mark

6.6

2.0

CAB-9K10A-EU

AC Power Cord, 250 V, 10 A; CEE 7/7 Plug

Europe

8.2

2.5

CAB-250V-10A-IS

AC Power Cord, 250 V, 10 A

Israel

8.2

2.5

CAB-250V-10A-CN

AC power cord, 250 V, 10 A

PR China

8.2

2.5

CAB-ACTW

AC power cord, 250 V, 10 A

Taiwan

7.5

2.3

CAB-C13-CBN

AC cabinet jumper power cord, 250, 10 A,

C13 to C14

2.2

0.68

CAB-C13-C14-2M

AC cabinet jumper power cord, 250 V, 10 A,

C13 to C14

6.6

2.0

CAB-9K10A-AU

AC power cord, 250 V, 10 A, 3112 plug,

Australia

8.2

2.5

CAB-N5K6A-NA

AC power cord, 200/240 V, 6 A,

North America

8.2

2.5

CAB-250V-10A-ID

AC power Cord, 250 V, 10 A,

India

8.2

2.5

CAB-9K10A-SW

AC power cord, 250 V, 10 A, MP232 plug

Switzerland

8.2

2.5

CAB-250V-10A-BR

AC power Cord, 250 V, 10 A

Brazil

8.2

2.5

CAB-9K10A-UK

AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug

United Kingdom

8.2

2.5

CAB-9K12A-NA

AC power cord, 125 V, 13 A, NEMA 5-15 plug

North America

8.2

2.5

CAB-AC-L620-C13

AC power cord, NEMA L6-20 to C13 connectors

6.6

2.0

CAB-9K10A-IT

AC power cord, 250 V, 10 A, CEI 23-16/VII plug

Italy

8.2

2.5

R2XX-DMYMPWRCORD

No power cord; PID option for ordering server with no power cord

NA

NA