Server Specifications
This appendix lists the physical, environmental, and power specifications for the server.
Physical Specifications
The following table lists the physical specifications for the server versions.
Description |
Specification |
Height |
1.7 in. (43.2 mm) |
Width |
16.9 in. (429.0 mm) |
Depth (length) |
Server only: 29.5 in. (740.3 mm) Server with slide rail: 31.0 in (787.4 mm) |
Weight |
Maximum: 37.5 lb. (17.0 Kg) Minimum: 29.0 lb. (13.2 Kg) |
Environmental Specifications
The following table lists the environmental requirements and specifications for the server.
Description |
Specification |
Temperature, Operating |
50 to 95°F (10 to 35°C) with no direct sunlight. Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level. |
Temperature, non-operating (when the server is stored or transported) |
–40 to 149°F (–40 to 65°C) |
Humidity (RH), operating |
10 to 90% |
Humidity (RH), non-operating (when the server is stored or transported) |
5 to 93% |
Altitude, operating |
0 to 10,000 feet |
Altitude, non-operating (when the server is stored or transported) |
0 to 40,000 feet |
Sound power level Measure A-weighted per ISO7779 LwAd (Bels) Operation at 73°F (23°C) |
5.5 |
Sound pressure level Measure A-weighted per ISO7779 LpAm (dBA) Operation at 73°F (23°C) |
40 |
Cisco Virtual Interface Card (VIC) Considerations
This section describes VIC card support and special considerations for this server.
Note |
If you use the Cisco Card NIC mode, you must also make a VIC Slot setting that matches where your VIC is installed. The options are Riser1, Riser2, and Flex-LOM. See NIC Mode and NIC Redundancy Settings for more information about NIC modes. |
VIC |
How Many Supported in Server |
Slots That Support VICs |
Primary Slot For Cisco UCS Manager Integration |
Primary Slot For Cisco Card NIC Mode |
Minimum Cisco IMC Firmware |
Cisco VIC 1455 APIC-PCIE-C25Q-04 |
2 PCIe |
PCIe 1 PCIe 2 |
PCIe 1 |
PCIe 1 |
4.0(1) |
Note |
This VIC supports 10/25-Gigabit with the following restrictions:
|
Power Specifications
System Workload Factor |
50% |
75% |
100% |
---|---|---|---|
Maximum Input Power |
409.91 W |
409.91 W |
409.91 W |
Input Power |
268.24 W |
338.59 W |
409.91 W |
Idle Input Power |
129.18 W |
129.18 W |
129.18 W |
Input Current |
1.13 A |
1.43 A |
1.72 A |
Air Flow |
31.69 cfm |
40 cfm |
48.43 cfm |
Cooling |
915.28 BTU/hr. |
1155.31 BTU/hr. |
1398.68 BTU/hr. |
System Workload Factor |
50% |
75% |
100% |
---|---|---|---|
Maximum Input Power |
429.85 W |
429.85 W |
429.85 W |
Input Power |
280.83 W |
355 W |
429.85 W |
Idle Input Power |
134.26 W |
134.26 W |
134.26 W |
Input Current |
1.19 A |
1.5 A |
1.81 A |
Air Flow |
33.18 cfm |
41.94 cfm |
50.78 cfm |
Cooling |
958.22 BTU/hr. |
1211.31 BTU/hr. |
1466.71 BTU/hr. |
Note |
Do not mix power supply types or wattages in the server. Both power supplies must be identical. |
You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:
The power specifications for the supported power supply options are listed in the following sections.
770 W AC Power Supply
This section lists the specifications for each 770 W AC power supply (Cisco part number APIC-PSU1-770W).
Description |
Specification |
AC Input Voltage |
Nominal range: 100–120 VAC, 200–240 VAC (Range: 90–132 VAC, 180–264 VAC) |
AC Input Frequency |
Nominal range: 50 to 60Hz (Range: 47–63 Hz) |
Maximum AC Input current |
9.5 A at 100 VAC 4.5 A at 208 VAC |
Maximum input volt-amperes |
950 VA at 100 VAC |
Maximum inrush current |
15 A (sub-cycle duration) |
Maximum hold-up time |
12 ms at 770 W |
Maximum output power per PSU |
770 W |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
Climate Savers Platinum Efficiency (80Plus Platinum certified) |
Form factor |
RSP2 |
Input connector |
IEC320 C14 |
1050 W DC Power Supply
This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV2-1050DC).
Description |
Specification |
DC Input Voltage |
Nominal range: -48 to -60 VDC (Range: -40 to -72 VDC) |
Maximum DC input current |
32 A at -40 VDC |
Maximum input wattage |
1234 W |
Maximum inrush current |
35 A (sub-cycle duration) |
Maximum hold-up time |
5 ms at 100% load (1050 W main and 36 W standby) |
Maximum output power per PSU |
1050 W on 12 VDC main power 36 W on 12 VDC standby power |
Power supply output voltage |
12 VDC |
Power supply standby voltage |
12 VDC |
Efficiency rating |
≥ 92% at 50% load |
Form factor |
RSP2 |
Input connector |
Fixed 3-wire block |
Power Cord Specifications
Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.
Note |
Only the approved power cords or jumper power cords listed below are supported. |
Description |
Length (Feet) |
Length (Meters) |
CAB-48DC-40A-8AWG DC power cord, -48 VDC, 40 A, 8 AWG Three-socket Mini-Fit connector to three-wire |
11.7 |
3.5 |
CAB-C13-C14-AC AC power cord, 10 A; C13 to C14, recessed receptacle |
9.8 |
3.0 |
CAB-250V-10A-AR AC power cord, 250 V, 10 A Argentina |
8.2 |
2.5 |
CAB-C13-C14-2M-JP AC Power Cord, C13 to C14 Japan PSE Mark |
6.6 |
2.0 |
CAB-9K10A-EU AC Power Cord, 250 V, 10 A; CEE 7/7 Plug Europe |
8.2 |
2.5 |
CAB-250V-10A-IS AC Power Cord, 250 V, 10 A Israel |
8.2 |
2.5 |
CAB-250V-10A-CN AC power cord, 250 V, 10 A PR China |
8.2 |
2.5 |
CAB-ACTW AC power cord, 250 V, 10 A Taiwan |
7.5 |
2.3 |
CAB-C13-CBN AC cabinet jumper power cord, 250, 10 A, C13 to C14 |
2.2 |
0.68 |
CAB-C13-C14-2M AC cabinet jumper power cord, 250 V, 10 A, C13 to C14 |
6.6 |
2.0 |
CAB-9K10A-AU AC power cord, 250 V, 10 A, 3112 plug, Australia |
8.2 |
2.5 |
CAB-N5K6A-NA AC power cord, 200/240 V, 6 A, North America |
8.2 |
2.5 |
CAB-250V-10A-ID AC power Cord, 250 V, 10 A, India |
8.2 |
2.5 |
CAB-9K10A-SW AC power cord, 250 V, 10 A, MP232 plug Switzerland |
8.2 |
2.5 |
CAB-250V-10A-BR AC power Cord, 250 V, 10 A Brazil |
8.2 |
2.5 |
CAB-9K10A-UK AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug United Kingdom |
8.2 |
2.5 |
CAB-9K12A-NA AC power cord, 125 V, 13 A, NEMA 5-15 plug North America |
8.2 |
2.5 |
CAB-AC-L620-C13 AC power cord, NEMA L6-20 to C13 connectors |
6.6 |
2.0 |
CAB-9K10A-IT AC power cord, 250 V, 10 A, CEI 23-16/VII plug Italy |
8.2 |
2.5 |
R2XX-DMYMPWRCORD No power cord; PID option for ordering server with no power cord |
NA |
NA |