Server Specifications

Server Specifications

This appendix lists the physical, environmental, and power specifications for the server.

Physical Specifications

The following table lists the physical specifications for the server versions.

Table 1. Physical Specifications

Description

Specification

Height

1.7 in. (43.2 mm)

Width

16.9 in. (429.0 mm)

Depth (length)

Server only: 29.5 in. (740.3 mm)

Server with slide rail: 31.0 in (787.4 mm)

Weight

Maximum: 37.5 lb. (17.0 Kg)

Minimum: 29.0 lb. (13.2 Kg)

Environmental Specifications

The following table lists the environmental requirements and specifications for the server.

Table 2. Physical Specifications

Description

Specification

Temperature, Operating

50 to 95°F (10 to 35°C) with no direct sunlight.

Derate the maximum temperature by 1°C per every 305 meters of altitude above sea level.

Temperature, non-operating

(when the server is stored or transported)

–40 to 149°F (–40 to 65°C)

Humidity (RH), operating

10 to 90%

Humidity (RH), non-operating

(when the server is stored or transported)

5 to 93%

Altitude, operating

0 to 10,000 feet

Altitude, non-operating

(when the server is stored or transported)

0 to 40,000 feet

Sound power level

Measure A-weighted per ISO7779 LwAd (Bels)

Operation at 73°F (23°C)

5.5

Sound pressure level

Measure A-weighted per ISO7779 LpAm (dBA)

Operation at 73°F (23°C)

40

Cisco Virtual Interface Card (VIC) Considerations

This section describes VIC card support and special considerations for this server.


Note


If you use the Cisco Card NIC mode, you must also make a VIC Slot setting that matches where your VIC is installed. The options are Riser1, Riser2, and Flex-LOM. See NIC Mode and NIC Redundancy Settings for more information about NIC modes.
Table 3. VIC Support and Considerations in This Server

VIC

How Many Supported in Server

Slots That Support VICs

Primary Slot For Cisco UCS Manager Integration

Primary Slot For Cisco Card NIC Mode

Minimum Cisco IMC Firmware

Cisco VIC 1455

APIC-PCIE-C25Q-04

2 PCIe

PCIe 1

PCIe 2

PCIe 1

PCIe 1

4.0(1)

The Cisco VIC 1455 has 4 ports: port-1, port-2, port-3, and port-4, from left to right. Given that the port channel is enabled:

  • Only two vNICs and vHBAs are available for use.

  • Port 0 and 1 are bundled as one port channel and port 2 and 3 are bundled as the other port channel.

This VIC supports 10/25-Gigabit with the following restrictions:

  • All ports must have the same speed.

  • Port 1 and port 2 is one pair, corresponding to eth2-1 on APIC. Port 3 and port 4 is another pair, corresponding to eth2-2 on APIC. Only one connection is allowed for each pair. For example, you can connect one cable to either port 1 or port 2, and you can connect another one cable to either port 3 or port 4. Do not connect two cables on any pair.

  • APIC-PCIE-IQ10GC or UCSC-PCIE-IQ10GC should always be installed in PCIE slot 1 for APIC M3/L3.

  • APIC-PCIE-IQ10GC or UCSC-PCIE-IQ10GC can use any ports or any pair of ports to connect to a leaf node.

  • APIC-PCIE-IQ10GC or UCSC-PCIE-IQ10GC have port numbering in the order | eth2-4 | eth2-3 | eth2-2 | eth2-1 | and the numbering on chassis is not valid.

  • From Release 4.2(5) the UCSC-PCIE-IQ10GC Intel X710 Quad Port 10GBase-T network interface card is supported for 10GBast-T connectivity to Cisco ACI leaf nodes.

Power Specifications

Table 4. M3 System Load Estimates

System Workload Factor

50%

75%

100%

Maximum Input Power

409.91 W

409.91 W

409.91 W

Input Power

268.24 W

338.59 W

409.91 W

Idle Input Power

129.18 W

129.18 W

129.18 W

Input Current

1.13 A

1.43 A

1.72 A

Air Flow

31.69 cfm

40 cfm

48.43 cfm

Cooling

915.28 BTU/hr.

1155.31 BTU/hr.

1398.68 BTU/hr.

Table 5. L3 System Load Estimates

System Workload Factor

50%

75%

100%

Maximum Input Power

429.85 W

429.85 W

429.85 W

Input Power

280.83 W

355 W

429.85 W

Idle Input Power

134.26 W

134.26 W

134.26 W

Input Current

1.19 A

1.5 A

1.81 A

Air Flow

33.18 cfm

41.94 cfm

50.78 cfm

Cooling

958.22 BTU/hr.

1211.31 BTU/hr.

1466.71 BTU/hr.


Note


Do not mix power supply types or wattages in the server. Both power supplies must be identical.

You can get more specific power information for your exact server configuration by using the Cisco UCS Power Calculator:

http://ucspowercalc.cisco.com

The power specifications for the supported power supply options are listed in the following sections.

770 W AC Power Supply

This section lists the specifications for each 770 W AC power supply (Cisco part number APIC-PSU1-770W).

Table 6. 770 W AC Specifications

Description

Specification

AC Input Voltage

Nominal range: 100–120 VAC, 200–240 VAC

(Range: 90–132 VAC, 180–264 VAC)

AC Input Frequency

Nominal range: 50 to 60Hz

(Range: 47–63 Hz)

Maximum AC Input current

9.5 A at 100 VAC

4.5 A at 208 VAC

Maximum input volt-amperes

950 VA at 100 VAC

Maximum inrush current

15 A (sub-cycle duration)

Maximum hold-up time

12 ms at 770 W

Maximum output power per PSU

770 W

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

Climate Savers Platinum Efficiency (80Plus Platinum certified)

Form factor

RSP2

Input connector

IEC320 C14

1050 W DC Power Supply

This section lists the specifications for each 1050 W DC power supply (Cisco part number UCSC-PSUV2-1050DC).

Table 7. 1050 W DC Specifications

Description

Specification

DC Input Voltage

Nominal range: -48 to -60 VDC

(Range: -40 to -72 VDC)

Maximum DC input current

32 A at -40 VDC

Maximum input wattage

1234 W

Maximum inrush current

35 A (sub-cycle duration)

Maximum hold-up time

5 ms at 100% load (1050 W main and 36 W standby)

Maximum output power per PSU

1050 W on 12 VDC main power

36 W on 12 VDC standby power

Power supply output voltage

12 VDC

Power supply standby voltage

12 VDC

Efficiency rating

≥ 92% at 50% load

Form factor

RSP2

Input connector

Fixed 3-wire block

Power Cord Specifications

Each power supply in the server has a power cord. Standard power cords or jumper power cords are available for connection to the server. The shorter jumper power cords, for use in racks, are available as an optional alternative to the standard power cords.


Note


Only the approved power cords or jumper power cords listed below are supported.


Table 8. Supported Power Cords

Description

Length (Feet)

Length (Meters)

CAB-48DC-40A-8AWG

DC power cord, -48 VDC, 40 A, 8 AWG

Three-socket Mini-Fit connector to three-wire

11.7

3.5

CAB-C13-C14-AC

AC power cord, 10 A; C13 to C14, recessed receptacle

9.8

3.0

CAB-250V-10A-AR

AC power cord, 250 V, 10 A

Argentina

8.2

2.5

CAB-C13-C14-2M-JP

AC Power Cord, C13 to C14

Japan PSE Mark

6.6

2.0

CAB-9K10A-EU

AC Power Cord, 250 V, 10 A; CEE 7/7 Plug

Europe

8.2

2.5

CAB-250V-10A-IS

AC Power Cord, 250 V, 10 A

Israel

8.2

2.5

CAB-250V-10A-CN

AC power cord, 250 V, 10 A

PR China

8.2

2.5

CAB-ACTW

AC power cord, 250 V, 10 A

Taiwan

7.5

2.3

CAB-C13-CBN

AC cabinet jumper power cord, 250, 10 A,

C13 to C14

2.2

0.68

CAB-C13-C14-2M

AC cabinet jumper power cord, 250 V, 10 A,

C13 to C14

6.6

2.0

CAB-9K10A-AU

AC power cord, 250 V, 10 A, 3112 plug,

Australia

8.2

2.5

CAB-N5K6A-NA

AC power cord, 200/240 V, 6 A,

North America

8.2

2.5

CAB-250V-10A-ID

AC power Cord, 250 V, 10 A,

India

8.2

2.5

CAB-9K10A-SW

AC power cord, 250 V, 10 A, MP232 plug

Switzerland

8.2

2.5

CAB-250V-10A-BR

AC power Cord, 250 V, 10 A

Brazil

8.2

2.5

CAB-9K10A-UK

AC power cord, 250 V, 10 A (13 A fuse), BS1363 plug

United Kingdom

8.2

2.5

CAB-9K12A-NA

AC power cord, 125 V, 13 A, NEMA 5-15 plug

North America

8.2

2.5

CAB-AC-L620-C13

AC power cord, NEMA L6-20 to C13 connectors

6.6

2.0

CAB-9K10A-IT

AC power cord, 250 V, 10 A, CEI 23-16/VII plug

Italy

8.2

2.5

R2XX-DMYMPWRCORD

No power cord; PID option for ordering server with no power cord

NA