Release Notes for Cisco Catalyst Blade Switch 3120 for HP, Cisco IOS Release 12.2(52)SE
Revised November 2, 2009
Cisco IOS Release 12.2(52)SE runs on the Cisco Catalyst Blade Switch 3120 for HP switches. These switches support stacking through Cisco StackWise Plus technology. Unless otherwise noted, the term switch refers to a standalone switch and to a switch stack.
These release notes include important information about Cisco IOS Release 12.2(52)SE and later and any limitations, restrictions, and caveats that apply to it. Verify that these release notes are correct for your switch:
•If you are installing a new switch, see the Cisco IOS release label on the rear panel of your switch.
•If your switch is on, use the show version privileged EXEC command. See the "Finding the Software Version and Feature Set" section.
•If you are upgrading to a new release, see the software upgrade filename for the software version. See the "Deciding Which Files to Use" section.
You can download the switch software from this site (registered Cisco.com users with a login password):
http://tools.cisco.com/support/downloads/go/Redirect.x?mdfid=268438038
This software release is part of a special release of Cisco IOS software that is not released on the same maintenance cycle that is used for other platforms. As maintenance releases and future software releases become available, they will be posted to Cisco.com in the Cisco IOS software area.
For the complete list of the Cisco Catalyst Blade Switch 3120 for HP documentation, see the "Related Documentation" section.
Note References in this document to the CBS3120G-S and CBS3120X-S switches also apply to the CBS3125G-S and CBS3125X-S switches, respectively.
Contents
These sections provide information about this release:
•Upgrading the Switch Software
•Minimum Cisco IOS Release for Major Features
•Obtaining Documentation and Submitting a Service Request
System Requirements
The system requirements are described in these sections:
•Device Manager System Requirements
•Cisco Network Assistant Compatibility
Hardware Supported
Table 1 lists the hardware supported on this release.
Table 1 Cisco Catalyst Blade Switch 3120 for HP Supported Hardware
Switch Hardware Description Supported by Minimum Cisco IOS ReleaseCBS3120G-S and CBS3120X-S
•18 internal Gigabit Ethernet 1000BASE-X downlink ports that connect to the blade enclosure.
•4 Gigabit Ethernet (RJ-45) uplink ports
•4 RJ-45 SFP module slots1 / 2 10-Gigabit Ethernet X2 module slots
•1 Ethernet management port (Fa0) used only for switch module management traffic
Cisco IOS Release 12.2(40)EX1
Cisco X2 transceiver modules (supported only on the CBS3120X-S model)
X2-10GB-SR V02 or later
X2-10GB-CX4 V03 or later
X2-10GB-LRM V03 or later
X2-10GB-LX4 V03 or later10 Gigabit Ethernet X2 ZR optical modules
Cisco IOS Release 12.2(40)EX1
Cisco IOS Release 12.2(50)SE
Cisco TwinGig Converter Module
Dual SFP2 X2 converter module to allow the switch to support SFP Gigabit Ethernet modules
Cisco IOS Release 12.2(40)EX1
SFP modules
1000BASE-LX/LH
1000BASE-SX
1000BASE-TSFP-10G-SR
SFP-10G-LRCisco IOS Release 12.2(40)EX1
Cisco IOS Release 12.2(50)SE
1 X2 module supported only on the CBS3120X-S model
2 SFP = small form-factor pluggable
Caution The Cisco Catalyst Blade Switch 3120 for HP switch modules do not support switch stacks with other types of blades switches as members. Combining the Cisco Catalyst Blade Switch 3120 for HP with other types of blade switches in a switch stack might cause the switch to work improperly or to fail.
Device Manager System Requirements
These sections describe the hardware and software requirements for using the device manager:
Hardware Requirements
Table 2 lists the minimum hardware requirements for running the device manager.
Table 2 Minimum Hardware Requirements
Processor Speed DRAM Number of Colors Resolution Font Size233 MHz minimum1
512 MB2
256
1024 x 768
Small
1 We recommend 1 GHz.
2 We recommend 1-GB DRAM.
Software Requirements
These are the supported operating systems and browsers for the device manager:
•Windows 2000, XP, Vista, and Windows Server 2003.
•Internet Explorer 5.5, 6.0, 7.0, Firefox 1.5, 2.0 or later.
The device manager verifies the browser version when starting a session, and it does not require a plug-in.
Cisco Network Assistant Compatibility
Cisco IOS 12.2(40)EX1 and later is only compatible with Cisco Network Assistant 5.3 and later. You can download Network Assistant from this URL:
http://www.cisco.com/pcgi-bin/tablebuild.pl/NetworkAssistant
For more information about Cisco Network Assistant, see the Release Notes for Cisco Network Assistant on Cisco.com.
Upgrading the Switch Software
These are the procedures for downloading software. Before downloading software, read this section for important information:
•Finding the Software Version and Feature Set
•Upgrading a Switch by Using the Device Manager or Network Assistant
•Upgrading a Switch by Using the CLI
•Recovering from a Software Failure
Finding the Software Version and Feature Set
The Cisco IOS image is stored as a bin file in a directory that is named with the Cisco IOS release. A subdirectory contains the files needed for web management. The image is stored on the system board flash device (flash:).
You can use the show version privileged EXEC command to see the software version that is running on your switch. The second line of the display shows the version.
Note Although the show version output always shows the software image running on the switch, the model name shown at the end of this display is the factory configuration (IP base feature set or IP services feature set) and does not change if you upgrade the software license.
You can also use the dir filesystem: privileged EXEC command to see the directory names of other software images that you might have stored in flash memory.
Deciding Which Files to Use
The upgrade procedures in these release notes describe how to perform the upgrade by using a combined tar file. This file contains the Cisco IOS image file and the files needed for the embedded device manager. You must use the combined tar file to upgrade the switch through the device manager. To upgrade the switch through the command-line interface (CLI), use the tar file and the archive download-sw privileged EXEC command.
Table 3 lists the filenames for this software release.
Note To use the IPv6 routing and IPv6 ACL features on the Cisco Catalyst Blade Switch 3120 for HP, you must purchase the IP services software license from Cisco.
The universal software images support multiple feature sets. Use the software activation feature to deploy a software license and to enable a specific feature set. For information about software activation, see the Cisco Software Activation for HP document on Cisco.com:
http://www.cisco.com/en/US/products/ps6748/products_installation_and_configuration_guides_list.html
Archiving Software Images
Before upgrading your switch software, make sure that you have archived copies of the current Cisco IOS release and the Cisco IOS release from which you are upgrading. You should keep these archived images until you have upgraded all devices in the network to the new Cisco IOS image and until you have verified that the new Cisco IOS image works properly in your network.
Cisco routinely removes old Cisco IOS versions from Cisco.com. See Product Bulletin 2863 for more information:
http://www.cisco.com/en/US/products/sw/iosswrel/ps5187/prod_bulletin0900aecd80281c0e.html
You can copy the bin software image file on the flash memory to the appropriate TFTP directory on a host by using the copy flash: tftp: privileged EXEC command.
Note Although you can copy any file on the flash memory to the TFTP server, it is time-consuming to copy all of the HTML files in the tar file. We recommend that you download the tar file from Cisco.com and archive it on an internal host in your network.
You can also configure the switch as a TFTP server to copy files from one switch to another without using an external TFTP server by using the tftp-server global configuration command. For more information about the tftp-server command, see the "Basic File Transfer Services Commands" section of the Cisco IOS Configuration Fundamentals Command Reference, Release 12.2, at this URL:
http://www.cisco.com/en/US/docs/ios/12_2/configfun/command/reference/ffun_r.html
Upgrading a Switch by Using the Device Manager or Network Assistant
You can upgrade switch software by using the device manager or Network Assistant. For detailed instructions, click Help.
Note When using the device manager to upgrade your switch, do not use or close your browser session after the upgrade process begins. Wait until after the upgrade process completes.
Upgrading a Switch by Using the CLI
This procedure is for copying the combined tar file to the switch. You copy the file to the switch from a TFTP server and extract the files. You can download an image file and replace or keep the current image.
To download software, follow these steps:
Step 1 Use Table 3 to identify the file that you want to download.
Step 2 Download the software image file. If you have a SmartNet support contract, go to this URL, and log in to download the appropriate files:
http://tools.cisco.com/support/downloads/pub/Redirect.x?mdfid=268438038
To download the universal software image files for a Cisco Catalyst Blade Switch 3120 for HP, click Blade Switches > Cisco Catalyst Blade Switch 3000 Series for HP >. To obtain authorization and to download the cryptographic software files, click Cisco Catalyst Blade Switch 3000 Series for HP Cryptographic Software.
Step 3 Copy the image to the appropriate TFTP directory on the workstation, and make sure that the TFTP server is properly configured.
For more information, see Appendix B in the software configuration guide for this release.
Step 4 Log into the switch through the console port or a Telnet session.
Step 5 (Optional) Ensure that you have IP connectivity to the TFTP server by entering this privileged EXEC command:
Switch# ping tftp-server-address
For more information about assigning an IP address and default gateway to the switch, see the software configuration guide for this release.
Step 6 Download the image file from the TFTP server to the switch. If you are installing the same version of software that is currently on the switch, overwrite the current image by entering this privileged EXEC command:
Switch# archive download-sw /overwrite /reload tftp:[[//location]/directory]/image-name.tarThe /overwrite option overwrites the software image in flash memory with the downloaded one.
The /reload option reloads the system after downloading the image unless the configuration has been changed and not saved.
For //location, specify the IP address of the TFTP server.
For /directory/image-name.tar, specify the directory (optional) and the image to download. Directory and image names are case sensitive.
This example shows how to download an image from a TFTP server at 198.30.20.19 and to overwrite the image on the switch:
Switch# archive download-sw /overwrite tftp://198.30.20.19/cbs31x0-universal-tar.122-40.EX1.tarYou can also download the image file from the TFTP server to the switch and keep the current image by replacing the /overwrite option with the /leave-old-sw option.
Recovering from a Software Failure
For additional recovery procedures, see the "Troubleshooting" chapter in the software configuration guide for this release.
Installation Notes
You can assign IP information to your switch by using these methods:
•The Express Setup program, as described in the switch getting started guide.
•The CLI-based setup program, as described in the switch hardware installation guide.
•The DHCP-based autoconfiguration, as described in the switch software configuration guide.
•Manually assigning an IP address, as described in the switch software configuration guide.
New Features
These sections describe the new supported hardware and the new and updated software features provided in this release:
•"New Hardware Features" section
•"New Software Features" section
New Hardware Features
For a list of all supported hardware, see the "Hardware Supported" section.
New Software Features
•Full QoS support for IPv6 traffic.
•Smart Install to allow a single point of management (director) in a network. You can use Smart Install to provide zero touch image and configuration upgrade of newly deployed switches and image and configuration downloads for any client switches.
•Cisco Medianet to enable intelligent services in the network infrastructure for a wide variety of video applications. One of the services of Medianet is auto provisioning for Cisco Digital Media Players and Cisco IP Video Surveillance cameras through Auto Smartports.
•Support for IP source guard on static hosts.
•RADIUS Change of Authorization (CoA) to change the attributes of a certain session after it is authenticated. When there is a change in policy for a user or user group in AAA, administrators can send the RADIUS CoA packets from the AAA server, such as Cisco Secure ACS to reinitialize authentication, and apply to the new policies.
•IEEE 802.1x User Distribution to allow deployments with multiple VLANs (for a group of users) to improve scalability of the network by load balancing users across different VLANs. Authorized users are assigned to the least populated VLAN in the group, assigned by RADIUS server.
•Support for critical VLAN with multiple-host authentication so that when a port is configured for multi-auth, and an AAA server becomes unreachable, the port is placed in a critical VLAN in order to still permit access to critical resources.
•Customizable web authentication enhancement to allow the creation of user-defined login, success, failure and expire web pages for local web authentication.
•Support for Network Edge Access Topology (NEAT) to change the port host mode and to apply a standard port configuration on the authenticator switch port.
•VLAN-ID based MAC authentication to use the combined VLAN and MAC address information for user authentication to prevent network access from unauthorized VLANs.
•MAC move to allow hosts (including the hosts connected behind an IP phone) to move across ports within the same switch without any restrictions to enable mobility. With MAC move, the switch treats the reappearance of the same MAC address on another port in the same way as a completely new MAC address.
•Support for including a hostname in the option 12 field of DHCPDISCOVER packets. This provides identical configuration files to be sent by using the DHCP protocol.
•DHCP snooping enhancement to support the selection of a fixed string-based format for the circuit-id sub-option of the Option 82 DHCP field.
•Support for VTP version 3 that includes support for configuring extended range VLANs (VLANs 1006 to 4094) in any VTP mode, enhanced authentication (hidden or secret passwords), propagation of other databases in addition to VTP, VTP primary and secondary servers, and the option to turn VTP on or off by port.
•Support for the LLPD-MED MIB and the CISCO-ADMISSION-POLICY-MIB.
•Support for up to 32 10 Gigabit Ethernet DWDM X2 optical modules.
Minimum Cisco IOS Release for Major Features
Table 4 lists the minimum software release (after the first release) required to support the major features of the Catalyst Blade Switch 3120 for HP. Features not listed are supported in all releases.
Limitations and Restrictions
You should review this section before you begin working with the switch. These are known limitations that will not be fixed, and there is not always a workaround. Some features might not work as documented, and some features could be affected by recent changes to the switch hardware or software.
This section contains these limitations:
Cisco IOS Limitations
These limitations apply to the Cisco Catalyst Blade Switch 3120 for HP:
•Cisco X2 Transceiver Modules and SFP Modules
Access Control List
•The Cisco Catalyst 3120 for HP Blade Switch has 964 TCAM entries available for ACLs in the default and routing SDM templates instead of the 1024 entries that are available on the Catalyst 3560 and Catalyst 3750 switches.
There is no workaround. (CSCse33114)
•When a MAC access list is used to block packets from a specific source MAC address, that MAC address is entered in the switch MAC-address table.
The workaround is to block traffic from the specific MAC address by using the mac address-table static mac-addr vlan vlan-id drop global configuration command. (CSCse73823)
Address Resolution Protocol
•The switch might place a port in an error-disabled state due to an Address Resolution Protocol (ARP) rate limit exception even when the ARP traffic on the port is not exceeding the configured limit. This could happen when the burst interval setting is 1 second, the default.
The workaround is to set the burst interval to more than 1 second. We recommend setting the burst interval to 3 seconds even if you are not experiencing this problem. (CSCse06827))
Cisco X2 Transceiver Modules and SFP Modules
•Cisco X2-10GB-LR transceiver modules with a version identification number lower than V03 might show intermittent frame check sequence (FCS) errors or be ejected from the switch during periods of operational shock greater than 50 g. There is no workaround. (CSCse14048)
•Cisco X2-10GB-CX4 transceiver modules with a version identification number lower than V03 might be difficult to insert because of a dimensional tolerance discrepancy. The workaround is to use modules with a version identification number of V03 or later. (CSCsg28558)
•Switches with the Cisco X2-10GB-LX4 transceiver modules with a version identification number before V03 might intermittently fail. The workaround is to use Cisco X2-10GB-LX4 transceiver modules with a version identification number of V03 or later. (CSCsh60076)
•Cisco GLC-GE-100FX SFP modules with a serial number between OPC0926xxxx and OPC0945xxxx might show intermittent module not valid, data, status, link-flapping, and FCS errors. The workaround is to use modules with serial numbers that are not in the specified range. (CSCsh59585)
•When switches are installed closely together and the uplink ports of adjacent switches are in use, you might have problems accessing the SFP module bale-clasp latch to remove the SFP module or the SFP cable (Ethernet or fiber). Use one of these workarounds:
–Allow space between the switches when installing them.
–In a switch stack, plan the SFP module and cable installation so that uplinks in adjacent stack members are not all in use.
–Use a long, small screwdriver to access the latch, and then remove the SFP module and cable. (CSCsd57938)
•When a Cisco X2-10GB-CX4 transceiver module is in the X2 transceiver module port and you enter the show controllers ethernet-controller tengigabitethernet privileged EXEC command, the command displays some fields as unspecified. This is the expected behavior based on IEEE 802.3ae. (CSCsd47344)
•The far-end fault optional facility is not supported on the GLC-GE-100FX SFP module. The workaround is to configure aggressive UDLD. (CSCsh70244).
Configuration
•If a half-duplex port running at 10 Mb/s receives frames with Inter-Packet Gap (IPG) that do not conform to Ethernet specifications, the switch might stop sending packets.
There is no workaround. (CSCec74610)
•When an excessive number (more than 100 packets per second) of Address Resolution Protocol (ARP) packets are sent to a Network Admission Control (NAC) Layer 2 IP-configured member port, a switch might display a message similar to this:
PLATFORM_RPC-3-MSG_THROTTLED: RPC Msg Dropped by throttle mechanism: type 0, class 51, max_msg 128, total throttled 984323
-Traceback= 6625EC 5DB4C0 5DAA98 55CA80 A2F2E0 A268D8
No workaround is necessary. Under normal conditions, the switch generates this notification when snooping the next ARP packet. (CSCse47548)
•When there is a VLAN with protected ports configured in fallback bridge group, packets might not be forwarded between the protected ports.
The workaround is to not configure VLANs with protected ports as part of a fallback bridge group. (CSCsg40322)
When a switch port configuration is set at 10 Mb/s half duplex, sometimes the port does not send in one direction until the port traffic is stopped and then restarted. You can detect the condition by using the show controller ethernet-controller or the show interfaces privileged EXEC commands.
The workaround is to stop the traffic in the direction in which it is not being forwarded, and then restart it after 2 seconds. You can also use the shutdown interface configuration command followed by the no shutdown command on the interface. (CSCsh04301)
•When line rate traffic is passing through a dynamic port, and you enter the switchport access vlan dynamic interface configuration command for a range of ports, the VLANs might not be assigned correctly. One or more VLANs with a null ID appears in the MAC address table instead.
The workaround is to enter the switchport access vlan dynamic interface configuration command separately on each port.(CSCsi26392)
EtherChannel
•In an EtherChannel running Link Aggregation Control Protocol (LACP), the ports might be put in the suspended or error-disabled state after a stack partitions or a member switch reloads. This occurs when
–The EtherChannel is a cross-stack EtherChannel with a switch stack at one or both ends.
–The switch stack partitions because a member reloads. The EtherChannel is divided between the two partitioned stacks, each with a stack master.
The EtherChannel ports are put in the suspended state because each partitioned stack sends LACP packets with different LACP Link Aggregation IDs (the system IDs are different). The ports that receive the packets detect the incompatibility and shut down some of the ports. Use one of these workarounds for ports in this error-disabled state:
–Enable the switch to recover from the error-disabled state.
–Enter the shutdown and the no shutdown interface configuration commands to enable the port.
The EtherChannel ports are put in the error-disabled state because the switches in the partitioned stacks send STP BPDUs. The switch or stack at the other end of the EtherChannel receiving the multiple BPDUs with different source MAC addresses detects an EtherChannel misconfiguration.
After the partitioned stacks merge, ports in the suspended state should automatically recover. (CSCse33842)
•When a switch stack is configured with a cross-stack EtherChannel, it might transmit duplicate packets across the EtherChannel when a physical port in the EtherChannel has a link-up or link-down event. This can occur for a few milliseconds while the switch stack adjusts the EtherChannel for the new set of active physical ports and can happen when the cross-stack EtherChannel is configured with either mode ON or LACP. This problem might not occur with all link-up or link-down events.
No workaround is necessary. The problem corrects itself after the link-up or link-down event. (CSCse75508)
•The switch might display tracebacks similar to this example when an EtherChannel interface port-channel type changes from Layer 2 to Layer 3 or the reverse:
15:50:11: %COMMON_FIB-4-FIBNULLHWIDB: Missing hwidb for fibhwidb Port-channel1 (ifindex 1632) -Traceback= A585C B881B8 B891CC 2F4F70 5550E8 564EAC 851338 84AF0C 4CEB50 859DF4 A7BF28 A98260 882658 879A58
There is no workaround. (CSCsh12472)
IEEE 802.1x Authentication
•If a supplicant using a Marvel Yukon network interface card (NIC) is connected to an IEEE 802.1x-authorized port in multihost mode, the extra MAC address of 0c00.0000.0000 appears in the MAC address table.
Use one of these workarounds (CSCsd90495):
–Configure the port for single-host mode to prevent the extra MAC address from appearing in the MAC address table.
–Replace the NIC with a new card.
•When MAC authentication bypass is configured to use Extensible Authentication Protocol (EAP) for authorization and critical authentication is configured to assign a critical port to an access VLAN:
–If the connected device is supposed to be unauthorized, the connected device might be authorized on the VLAN that is assigned to the critical port instead of to a guest VLAN.
–If the device is supposed to be authorized, it is authorized on the VLAN that is assigned to the critical port.
Use one of these workarounds (CSCse04534):
–Configure MAC authentication bypass to not use EAP.
–Define your network access profiles to not use MAC authentication bypass. For more information, see the Cisco Access Control Server (ACS) documentation.
•When IEEE 802.1x authentication with VLAN assignment is enabled, a CPUHOG message might appear if the switch is authenticating supplicants in a switch stack.
The workaround is not use the VLAN assignment option. (CSCse22791)
Multicasting
•Multicast packets with a time-to-live (TTL) value of 0 or 1 are flooded in the incoming VLAN when all of these conditions are met:
–Multicast routing is enabled in the VLAN.
–The source IP address of the packet belongs to the directly connected network.
–The TTL value is either 0 or 1.
The workaround is to not generate multicast packets with a TTL value of 0 or 1, or disable multicast routing in the VLAN. (CSCeh21660)
•Multicast packets denied by the multicast boundary access list are flooded in the incoming VLAN when all of these conditions are met:
–Multicast routing is enabled in the VLAN.
–The source IP address of the multicast packet belongs to a directly connected network.
–The packet is denied by the IP multicast boundary access-list configured on the VLAN.
There is no workaround. (CSCei08359)
•Reverse path forwarding (RPF) failed multicast traffic might cause a flood of Protocol Independent Multicast (PIM) messages in the VLAN when a packet source IP address is not reachable.
The workaround is to not send RPF-failed multicast traffic, or make sure that the source IP address of the RPF-failed packet is reachable. (CSCsd28944)
•If the clear ip mroute privileged EXEC command is used when multicast packets are present, it might cause temporary flooding of incoming multicast traffic in the VLAN.
There is no workaround. (CSCsd45753)
•When you configure the ip igmp max-groups number and ip igmp max-groups action replace interface configuration commands and the number of reports exceed the configured max-groups value, the number of groups might temporarily exceed the configured max-groups value. No workaround is necessary because the problem corrects itself when the rate or number of IGMP reports are reduced. (CSCse27757)
•When you configure the IGMP snooping throttle limit by using the ip igmp max-groups number interface configuration on a port-channel interface, the groups learned on the port-channel might exceed the configured throttle limit number when all of these conditions are true:
–The port-channel is configured with member ports across different switches in the stack.
–One of the member switches reloads.
–The member switch that is reloading has a high rate of IP IGMP joins arriving on the port-channel member port.
The workaround is to disable the IGMP snooping throttle limit by using the no ip igmp max-groups number interface configuration command and then to reconfigure the same limit again. (CSCse39909)
Quality of Service (QoS)
•When QoS is enabled and the egress port receives pause frames at the line rate, the port cannot send packets.
There is no workaround. (CSCeh18677)
•Egress shaped round robin (SRR) sharing weights do not work properly with system jumbo MTU frames.
There is no workaround. (CSCsc63334)
•In a hierarchical policy map, if the VLAN-level policy map is attached to a VLAN interface and the name of the interface-level policy map is the same as that for another VLAN-level policy map, the switch rejects the configuration, and the VLAN-level policy map is removed from the interface.
The workaround is to use a different name for the interface-level policy map. (CSCsd84001)
•If the ingress queue has low buffer settings and the switch sends multiple data streams of system jumbo MTU frames at the same time at the line rate, the frames are dropped at the ingress.
There is no workaround. (CSCsd72001)
•When you use the srr-queue bandwidth limit interface configuration command to limit port bandwidth, packets that are less than 256 bytes can cause inaccurate port bandwidth readings. The accuracy is improved when the packet size is greater than 512 bytes. There is no workaround. (CSCsg79627)
•If QoS is enabled on a switch and the switch has a high volume of incoming packets with a maximum transmission unit (MTU) size greater than 1512 bytes, the switch might reload.
Use one of these workarounds:
– Use the default buffer size.
– Use the mls qos queue-set output qset-id buffers allocation1 ... allocation4 global configuration command to allocate the buffer size. The buffer space for each queue must be at least 10 percent. (CSCsx69718)
RADIUS
RADIUS change of authorization (COA) reauthorization is not supported on the critical auth VLAN.
There is no workaround. (CSCta05071)
Routing
•The switch stack might reload if the switch runs with this configuration for several hours, depleting the switch memory and causing the switch to fail:
–The switch has 400 Open Shortest Path First (OSPF) neighbors.
–The switch has thousands of OSPF routes.
The workaround is to reduce the number of OSPF neighbors to 200 or less. (CSCse65252)
•When the PBR is enabled and QoS is enabled with DSCP settings, the CPU utilization might be high if traffic is sent to unknown destinations.
The workaround is to not send traffic to unknown destinations. (CSCse97660)
SPAN and RSPAN
•When egress SPAN is running on a 10-Gigabit Ethernet port, only about 12 percent of the egress traffic is monitored.
There is no workaround. This is a hardware limitation. (CSCei10129)
•When the logging event-spanning-tree interface configuration command is configured and logging to the console is enabled, a topology change might generate a large number of logging messages, causing high CPU utilization. CPU utilization can increase with the number of spanning-tree instances and the number of interfaces configured with the logging event-spanning-tree interface configuration command. This condition adversely affects how the switch operates and could cause problems such as STP convergence delay.
High CPU utilization can also occur with other conditions, such as when debug messages are logged at a high rate to the console.
Use one of these workarounds (CSCsg91027):
–Disable logging to the console.
–Rate-limit logging messages to the console.
–Remove the logging event spanning-tree interface configuration command from the interfaces.
•The far-end fault optional facility is not supported on the GLC-GE-100FX SFP module.
The workaround is to configure aggressive UDLD. (CSCsh70244).
VLANs
When the domain is authorized in the guest VLAN on a member switch port without link loss and an Extensible Authentication Protocol over LAN (EAPOL) is sent to an IEEE 802.1x supplicant to authenticate, the authentication fails. This problem happens intermittently with certain stacking configurations and only occurs on the member switches.
The workaround is to enter the shut and no shut interface configuration commands on the port to reset the authentication status. (CSCsf98557)
Stacking
•When using the logging console global configuration command, low-level messages appear on both the stack master and the stack member consoles.
The workaround is to use the logging monitor global configuration command to set the severity level to block the low-level messages on the stack member consoles. (CSCsd79037)
•If a new member switch joins a switch stack within 30 seconds of a command to copy the switch configuration to the running configuration of the stack master, the new member might not get the latest running configuration and might not operate properly.
The workaround is to reboot the new member switch. Use the remote command all show run privileged EXEC command to compare the running configurations of the stack members. (CSCsf31301)
•When the flash memory of a stack member is almost full, it might take longer to start up than other member switches. This might cause that switch to miss the stack-master election window. As a result, the switch might fail to become the stack master even though it has the highest priority.
The workaround is to delete files in the flash memory to create more free space. (CSCsg30073)
•The error message %DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND might appear for a switch stack under these conditions:
–IEEE 802.1 is enabled.
–A supplicant is authenticated on at least one port.
–A new member joins a switch stack.
You can use one of these workarounds:
–Enter the shutdown and the no shutdown interface configuration commands to reset the port.
–Remove and reconfigure the VLAN. (CSCsi26444)
•When you use the switch renumber global configuration command to renumber a member switch in a switch stack and then reload the switch, the internal server-facing ports do not have the required default of spanning-tree portfast enabled.
The workaround is to apply the switch provision configuration before you reboot the switch. Enter both the switch current-stack-member-number renumber new-stack-member-number and the switch stack-member-number provision type global configuration commands, and reload the switch. (CSCsl63862)
•If you enter the show tech-support privileged EXEC command after you enter the remote command {all | stack-member-number} privileged EXEC command, the complete output does not appear.
The workaround is to use the session stack-member-number privileged EXEC command. (CSCsz38090)
Device Manager Limitations
•When you are prompted to accept the security certificate and you click No, you only see a blank screen, and the device manager does not start.
The workaround is to click Yes when you are prompted to accept the certificate. (CSCef45718)
•If you launch the device manager from a Firefox web browser, an invalid certificate alert appears. If you launch the device manager from an Internet Explorer 7.0 browser, a certificate error appears.
The workaround when using Firefox is to either temporarily or permanently accept the certificate. If you temporarily accept the certificate, close and then reopen the Firefox browser window. If you permanently accept the certificate, delete the certificate, and then close and restart Firefox:
–If you are using Firefox version 1.5, choose Tools > Options > Advanced > Security > View Certificates > Web Sites, select the certificate, and click Delete.
–If you are using Firefox version 2.0, choose Tools > Options > Advanced > Encryption > View Certificates > Web Sites, select the certificate, and click Delete.
The workaround when using Internet Explorer is to click Click here for Options in the warning message, and click Display Blocked Content. Close the browser window, and launch a new session. (CSCsk80229)
Important Notes
These sections describe the important notes related to this software release:
Cisco IOS Notes
These notes apply to Cisco IOS software:
•If the switch requests information from the Cisco Secure Access Control Server (ACS) and the message exchange times out because the server does not respond, a message similar to this appears:
00:02:57: %RADIUS-4-RADIUS_DEAD: RADIUS server 172.20.246.206:1645,1646 is not responding.If this message appears, make sure that there is network connectivity between the switch and the ACS. You should also make sure that the switch has been properly configured as an AAA client on the ACS.
•If the switch has interfaces with automatic QoS for voice over IP (VoIP) configured and you upgrade the switch software to Cisco IOS Release 12.2(40)EX1 or later, when you enter the auto qos voip cisco-phone interface configuration command on another interface, you might see this message:
AutoQoS Error: ciscophone input service policy was not properly appliedpolicy map AutoQoS-Police-CiscoPhone not configuredIf this happens, enter the no auto qos voip cisco-phone interface command on all interfaces with this configuration to delete it. Then enter the auto qos voip cisco-phone command on each of these interfaces to reapply the configuration.
Device Manager Notes
These notes apply to the device manager:
•You cannot create and manage switch clusters through the device manager. To create and manage switch clusters, use the CLI or Cisco Network Assistant.
•We recommend this browser setting to reduce the time needed to display the device manager from Microsoft Internet Explorer.
From Microsoft Internet Explorer:
1. Choose Tools > Internet Options.
2. Click Settings in the "Temporary Internet files" area.
3. From the Settings window, choose Automatically.
4. Click OK.
5. Click OK to exit the Internet Options window.
•The HTTP server interface must be enabled to display the device manager. By default, the HTTP server is enabled on the switch. Use the show running-config privileged EXEC command to see if the HTTP server is enabled or disabled.
Beginning in privileged EXEC mode, follow these steps to configure the HTTP server interface:
•The device manager uses the HTTP protocol (the default is port 80) and the default method of authentication (the enable password) to communicate with the switch through any of its Ethernet ports and to allow switch management from a standard web browser.
If you change the HTTP port, you must include the new port number when you enter the IP address in the browser Location or Address field (for example, http://10.1.126.45:184 where 184 is the new HTTP port number). You should write down the port number through which you are connected. Use care when changing the switch IP information.
If you are not using the default method of authentication (the enable password), you need to configure the HTTP server interface with the method of authentication used on the switch.
Beginning in privileged EXEC mode, follow these steps to configure the HTTP server interface:
If you use Internet Explorer Version 5.5 and select a URL with a nonstandard port at the end of the address (for example, www.cisco.com:84), you must enter http:// as the URL prefix. Otherwise, you cannot launch the device manager.
Open Caveats
•CSCsy85676
When you configure an ACL and enter the access-group interface configuration command to apply it to an interface for web authentication, the output from the show epm session ip-address or show ip access_list interface interface-id privileged EXEC command does not show any web authentication filter ID.
There is no workaround.
•CSCsz18634
On a switch running Cisco IOS release 12.2(46)SE, the output of the show interfaces privileged EXEC command shows 0 packets for port channel input and output rates.
The workaround is to reload the switch by entering the reload privileged EXEC command.
•CSCtb08823
SNMP requests on the stpxRSTPPortRoleTable object only return information for the stack master.
There is no workaround.
•CSCtb25230
When a switch stack is configured with DHCP snooping enabled on the host VLAN, hosts connected to the stack master receive bootp packets, but the a packet might not be forwarded to the end hosts connected to stack member switches. The behavior depends on which interface in the stack received the packet.
The workaround is to disable DHCP snooping for the affected VLAN.
•CSCtb88425
If you press the MODE button to enter Express Setup setup mode after the switch has received an IP address dynamically through DHCP, HTTP authentication with the default username and password cisco/cisco fails.
Use one of these workarounds:
–Downgrade the image to 12.2(46)SE where there is no HTTP authentication.
–Use the console to perform initial configuration.
•CSCtc02635
On switches running Cisco IOS release 12.2(50)SE3 running MAC authentication bypass with multidomain authentication (MDA, IP phones connected to a port might not be able to regain network connectivity in the VOICE domain if the session times out and all RADIUS servers are unreachable.
There is no workaround.
Resolved Caveats
•CSCsi52914
When you are configuring a SPAN session, this message might erroneously appear even when two source sessions are not configured:
% Platform can support a maximum of 2 source sessions
The workaround is to reboot the switch stack.
•CSCsi65551
In certain situations during master switch failover, a VLAN that has been error disabled on a port might be re-enabled after the master switch failover, even though the port has not been configured for automatic recovery.
There is no workaround.
•CSCsi73653
After a stack-master failover, switch ports in the stack cannot detect new devices. This only affects new devices connected to the switch ports. Devices that were connected to active ports before the failover remain in a trusted state.
There is no workaround.
•CSCsj22678
A delay can occur when you remove an access control list (ACL) from a switch stack under these conditions:
–A QoS, per-port policy map is attached to a large number of SVIs in the stack.
–A per-VLAN QoS, per-port policer policy map is attached to a large number of switched virtual interfaces (SVIs) in the stack.
–The ACL to be removed is being used by the policy map.
–There are three or more switches in the stack.
The delay can increase, up to 30 minutes, depending on the number of SVIs that are attached to the policy map. The delay does not affect the operation of the policy-map. However, either of these workarounds will reduce the length of the delay:
–Remove the access control entries (ACEs) from the destination ACL, leaving the ACL empty. (The effect is the same as removing the ACL itself.)
–Detach the affected policy-maps from all the attached VLANs and SVIs, remove the ACL from the policy-maps, and then reattach the policy-maps back to the original SVIs.
•CSCsk19926
Traffic is not received on a member port in a switch stack under these conditions:
–The port is in a cross-stack EtherChannel.
–One or more of the master switch Cisco TwinGig Converter Module ports are in the cross-stack EtherChannel.
–This member switch has been reloaded.
The workaround is to enter the shutdown and no shutdown interface configuration commands on the affected interface or to reload the entire stack instead of a single member switch.
•CSCsl49153
You might receive a traceback message when you use the no interface port-channel global configuration command to delete interfaces from an EtherChannel that has port channels on multiple stack members.
The workaround is to save the configuration and to reload the stack.
•CSCso15367
The CLI output for the StackWise Plus port 2 shows the output for the StackWise Plus port 1 and vice versa.
There is no workaround.
•CSCsw68528
On switches running Cisco IOS Release 12.2(44)SE or 12.2(46)SE, when you enter the show mvr interface interface-id members privileged EXEC command to see status of an MVR port, an MVR member port that is not connected always shows as ACTIVE.
The workaround is to use the show mvr interface interface-id or the show mvr members privileged EXEC command. These command outputs show the correct status of an MVR port.
•CSCsw69015
When you enter the mvr vlan vlan-id global configuration command to create an MVR VLAN and enable MVR on the switch by entering the mvr global configuration command, if you enter the show mvr interface interface-id members privileged EXEC command, the output shows the MVR groups on the interface. However, if you enable MVR first and then create the MVR VLAN, the MVR groups are not displayed correctly.
•CSCsw69335
In a stacked environment, IP ACLs are not applied to interfaces on member switches unless IP routing is enabled.
The workaround when applying IP ACLs to stack member interfaces is to enable IP routing on the stack master by entering the ip routing global configuration command.
•CSCsw72527
When a switch sends an ARP request to find the MAC address of the default gateway, the switch sends the request in the wrong VLAN. An ARP entry associating the MAC address with the wrong VLAN is added to the table.
The workaround is to use the no arp arpa global configuration command in all VLANs with IDs lower than the ID of the correct VLAN.
•CSCsw96933
A switch running Cisco IOS Release 12.2(46)SE might lose packets for up to 30 seconds when a link fails. This occurs in some multiple spanning-tree (MST) topologies.
There is no workaround.
•CSCsx71632
When VLAN-based quality of service (QoS) is enabled and then disabled on an interface by entering the mls qos vlan-based interface configuration command followed by the no version of the command, the port policy is not applied properly and could result in undefined behavior for packets matching the port policy.
The workaround is to remove the port policy by entering the no service-policy input policy-map-name interface configuration command and then reapply it to the interface.
•CSCsx78068
If you enable 802.1Q native VLAN tagging by entering the vlan dot1q tag native global configuration command and then change the native VLAN ID on an ingress trunk port by entering the switchport trunk native vlan vlan-id interface command, untagged traffic is forwarded instead of being dropped.
The workaround is to use one of these methods:
–Enter a shutdown followed by a no shutdown interface configuration command on the trunk port.
–Disable and then reenable native VLAN tagging by entering the no vlan dot1q tag native global configuration command followed by the vlan dot1q tag native command.
•CSCsy90265
If you repeatedly enter the show tech-support privileged EXEC command, the switch might leak memory and, in some cases, shut down.
The workaround is to reload the switch to clear the memory after repeated use of the show tech-support command.
•CSCsz66428
When flow control is enabled on a port-channel interface and you enter the flowcontrol receive on interface configuration command, the bundle is not enabled after the switch restarts. The command appears in the port-channel interface running configuration but does not appear in the switch running configuration. A message such as this appears:
%EC-5-CANNOT_BUNDLE2: Gi0/27 is not compatible with Po1 and will be suspended (flow control receive of Gi0/27 is on, Po1 is off)%EC-5-CANNOT_BUNDLE2: Gi0/28 is not compatible with Po1 and will be suspended (flow control receive of Gi0/28 is on, Po1 is off)Use one of these workarounds:
–To manually configure the port-channel interface, enter the flowcontrol receive on interface configuration command.
–To add the flow-control configuration to the interface after the switch restarts, use an EEM script similar to this:
event manager applet Add_flowcontrol_on_restartevent syslog pattern SYS-5-RESTARTaction 1 cli command "en"action 2 cli command "conf t"action 3 cli command "inter port 1"action 4 cli command "flowcontrol receive on"For action 3, specify the port-channel interface.
•CSCsz72234
In a VPN routing/forwarding (VRF) instance, a port channel is configured, and the default route is in the global routing table. If a link shuts down while the other links remain up, the port channel might not forward traffic.
Use one of these workarounds:
–Enter the shutdown interface configuration command, and then enter the no shutdown interface command.
–In the VRF instance, configure the links in the port channel as Layer 2 access links, and configure a switch virtual interface (SVI).
•CSCsz88857
When an interface on the stack master is a member of an EtherChannel and the channel group number is removed before a master switch changeover, you can not use the same group number when you recreate the EtherChannel after the changeover.
These are possible workarounds:
–Reload the switches in the EtherChannel into the channel group that you were not able to create.
–Use a new channel group number to bundle the physical interfaces in an EtherChannel.
–Reconfigure the EtherChannel before the master switch changeover.
•CSCta53893
If the host is in multiple-authentication (multiauth) mode and you configure the fallback authentication process as IEEE 802.1x or MAc authentication bypass, the per-user ACL does not work when the port uses web authentication as the fallback method and then uses 802.1x or MAC authentication bypass as the fallback method.
The workaround is to restart the switch.
•CSCta57846
The switch unexpectedly reloads when copying a configuration file from a remote server or from flash memory containing logging file flash:
The workaround is to enter the logging file flash:filename global configuration command to configure logging to flash instead of copying to flash.
•CSCta78502
When you have configured a login banner by entering the banner login c message c global configuration command and the switch reloads, the output of banner is missing a carriage return, making the format incorrect.
There is no workaround.
•CSCta80514
When you enable MAC address learning on a VLAN and then change the interface configuration (such as adding the VLAN to the list of VLANs allowed on a trunk), MAC address learning is not disabled on the interface. If you disable MAC address learning on the switch, high CPU utilization occurs when the local forwarding manager tries to ut does not learn MAC addresses.
There is no workaround.
•CSCtb77378
When you use IEEE 802.1x authentication with web authentication and an HTTP page opens, the switch redirects the user to an HTTP login page, not a HTTPS login page.
The workaround is to remove the custom banner.
•CSCtb84303
In a switch stack, when the SNMP vlan change (vmMembershipEntry) MIB is sent to a member switch other than the stack master, line protocol and notification flapping occurs.
There is no workaround.
•CSCtb97439
When remote neighbors change, the LLDP MIB does not properly update the remote neighbors.
The workaround is to clear the LLDP table by entering the clear lldp table privileged EXEC command.
Documentation Updates
•Updates to the Software Documentation
•Updates to the Switch Getting Started Guide
•Updates to the Switch Getting Started Guide
•Updates for the System Message Guide
Updates to the Software Documentation
•The switch does not support ISL trunking.
Update to the "Configuring IEEE 802.1x Port-Based Authentication" Chapter
Common Session ID
Authentication manager uses a single session ID (referred to as a common session ID) for a client no matter which authentication method is used. This ID is used for all reporting purposes, such as the show commands and MIBs. The session ID appears with all per-session syslog messages.
The session ID includes:
•The IP address of the Network Access Device (NAD)
•A monotonically increasing unique 32 bit integer
•The session start time stamp (a 32 bit integer)
This example shows how the session ID appears in the output of the show authentication command. The session ID in this example is 160000050000000B288508E5:
Switch# show authentication sessions
Interface MAC Address Method Domain Status Session IDFa4/0/4 0000.0000.0203 mab DATA Authz Success 160000050000000B288508E5This is an example of how the session ID appears in the syslog output. The session ID in this example is also160000050000000B288508E5:
1w0d: %AUTHMGR-5-START: Starting 'mab' for client (0000.0000.0203) on Interface Fa4/0/4 AuditSessionID 160000050000000B288508E51w0d: %MAB-5-SUCCESS: Authentication successful for client (0000.0000.0203) on Interface Fa4/0/4 AuditSessionID 160000050000000B288508E51w0d: %AUTHMGR-7-RESULT: Authentication result 'success' from 'mab' for client (0000.0000.0203) on Interface Fa4/0/4 AuditSessionID 160000050000000B288508E5The session ID is used by the NAD, the AAA server, and other report-analyzing applications to identify the client. The ID appears automatically. No configuration is required.
Update to the "Configuring Embedded Event Manager" Chapter
Embedded Event Manager 3.2
Embedded Event Manager (EEM) is a distributed and customized approach to event detection and recovery offered directly in a Cisco IOS device. EEM offers the ability to monitor events and take informational, corrective, or any desired EEM action when the monitored events occur or when a threshold is reached. An EEM policy is an entity that defines an event and the actions to be taken when that event occurs.
EEM 3.2 is supported in Cisco IOS Release 12.2(52)SE and later releases, and introduced many new features.
EEM 3.2 introduces the following new event detectors:
•Neighbor Discovery—Neighbor Discovery event detector provides the ability to publish a policy to respond to automatic neighbor detection when:
–a Cisco Discovery Protocol (CDP) cache entry is added, deletedn or updated.
–a Link Layer Discovery Protocol (LLDP) cache entry is added, deleted, or updated.
–an interface link status changes.
–an interface line status changes.
•Identity—Identity event detector generates an event when AAA authorization and authentication is successful, when failure occurs, or after normal user traffic on the port is allowed to flow.
•Mac-Address-Table—Mac-Address-Table event detector generates an event when a MAC address is learned in the MAC address table.
Note The Mac-Address-Table event detector is supported only on switch platforms and can be used only on Layer 2 interfaces where MAC addresses are learned. Layer 3 interfaces do not learn addresses and routers do not usually support the mac-address-table infrastructure needed to notify EEM of a learned MAC address.
EEM 3.2 also introduces new CLI commands to support the applets to work with the new event detectors.
For further details about EEM 3.2 features, see the Embedded Event Manager 3.2 document.
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_3.2.html
For the complete EEM document set, see these documents:
•Embedded Event Manager Overview
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_overview.html
•Writing Embedded Event Manager Policies Using the Cisco IOS CLI
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_policy_cli.html
•Writing Embedded Event Manager Policies Using Tcl
http://www.cisco.com/en/US/docs/ios/netmgmt/configuration/guide/nm_eem_policy_tcl.html
Updates to the Switch Getting Started Guide
When you launch Express Setup, you are prompted for the switch password. Enter the default password, cisco. The switch ignores text in the username field. Before you complete and exit Express Setup, you must change the password from the default password, cisco.
Updates for the System Message Guide
These messages were added:
Error Message DOT1X-5-FAIL: Authentication failed for client ([chars]) on Interface [chars] AuditSessionID [chars]Explanation The authentication was unsuccessful. The first [chars] is the client ID, the second [chars] is the interface, and the third [chars] is the session ID.
Recommended Action No action is required.
Error Message DOT1X-4-MEM_UNAVAIL: Memory was not available to perform the 802.1X action. AuditSessionID [chars]Explanation The system memory is not sufficient to perform the IEEE 802.1x authentication. [chars] is the session ID.
Recommended Action Reduce other system activity to reduce memory demands.
Error Message DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on Interface [chars] AuditSessionID [chars]Explanation Authentication was successful. The first [chars] is the client ID, the second [chars] is the interface, and the third [chars] is the session ID.
Recommended Action No action is required.
Error Message DOT1X_SWITCH-5-ERR_ADDING_ADDRESS: Unable to add address [enet] on [chars] AuditSessionID [chars]Explanation The client MAC address could not be added to the MAC address table because the hardware memory is full or the address is a secure address on another port. This message might appear if IEEE 802.1x is enabled. [enet] is the client MAC address, the first [chars] is the interface, and the second [chars] is the session ID.
Recommended Action If the hardware memory is full, remove some of the dynamic MAC addresses. If the client address is on another port, remove it from that port.
Error Message DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a primary VLAN to an IEEE 802.1x port, which is not allowed. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Use a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid secondary VLAN [dec] to PVLAN host 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a nonsecondary VLAN to a private VLAN host IEEE 802.1x port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the mode of the port so that it is no longer a PVLAN host port or use a valid secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_PRIMARY_VLAN_NOT_FOUND: Attempt to assign VLAN [dec], whose primary VLAN does not exist or is shutdown, to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a private VLAN whose primary VLAN does not exist or is shut down. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Make sure the primary VLAN exists and is not shut down. Verify that the private VLAN is associated with a primary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SEC_VLAN_INVALID: Attempt to assign secondary VLAN [dec] to non-PVLAN host 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a secondary VLAN to a port that is not a private VLAN host port, which is not allowed. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the mode of the port so that it is configured as a private VLAN host port, or use a different VLAN that is not configured as a secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SPAN_DST_PORT: Attempt to assign VLAN [dec] to 802.1x port [chars], which is configured as a SPAN destination AuditSessionID [chars]Explanation An attempt was made to assign a VLAN to an IEEE 802.1x port that is configured as a Switched Port Analyzer (SPAN) destination port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change the SPAN configuration so that the port is no longer a SPAN destination port, or change the configuration so that no VLAN is assigned.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_MDA_INACTIVE: Multi-Domain Authentication cannot activate because Data and Voice VLANs are the same on port AuditSessionID [chars]Explanation Multi-Domain Authentication (MDA) host mode cannot start if the configured data VLAN on a port is the same as the voice VLAN. [chars] is the port session ID.
Recommended Action Change either the voice VLAN or the access VLAN on the interface so that they are not the same. MDA then starts.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_VVLAN: Data VLAN [dec] on port [chars] cannot be equivalent to the Voice VLAN AuditSessionID [chars]Explanation An attempt was made to assign a data VLAN to an IEEE 802.1x port that is the same as the voice VLAN. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Change either the voice VLAN or the IEEE 802.1x-assigned VLAN on the interface so that they are not the same.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INTERNAL: Attempt to assign internal VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is used internally and cannot be assigned to this port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Explanation Assign a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INVALID: Attempt to assign invalid VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is out of range. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Update the configuration to use a valid VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND: Attempt to assign non-existent or shutdown VLAN [chars] to 802.1x port [chars] AuditSessionID [chars]Explanation An attempt was made to assign a VLAN to an IEEE 802.1x port, but the VLAN was not found in the VLAN Trunking Protocol (VTP) database. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action Make sure the VLAN exists and is not shutdown or use another VLAN.
These messages have been deleted:
Error Message DOT1X-4-MEM_UNAVAIL: Memory was not available to perform the 802.1X action.Explanation The system memory is not sufficient to perform the IEEE 802.1x authentication.
Recommended Action Reduce other system activity to reduce memory demands.
Error Message DOT1X-5-SUCCESS: Authentication successful for client ([chars]) on Interface [chars]Explanation Authentication was successful. [chars] is the interface.
Recommended Action No action is required.
Error Message DOT1X_SWITCH-5-ERR_ADDING_ADDRESS: Unable to add address [enet] on [chars]Explanation The client MAC address could not be added to the MAC address table because the hardware memory is full or the address is a secure address on another port. This message might appear if IEEE 802.1x is enabled. [enet] is the client MAC address, and [chars] is the interface.
Recommended Action If the hardware memory is full, remove some of the dynamic MAC addresses. If the client address is on another port, remove it from that port.
Error Message DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign a primary VLAN to an IEEE 802.1x port, which is not allowed. [dec] is the VLAN, and [chars] is the port.
Recommended Action Use a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid secondary VLAN [dec] to PVLAN host 802.1x port [chars]Explanation An attempt was made to assign a nonsecondary VLAN to a private VLAN host IEEE 802.1x port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the mode of the port so that it is no longer a private VLAN host port, or use a valid secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_PRIMARY_VLAN_NOT_FOUND: Attempt to assign VLAN [dec], whose primary VLAN does not exist or is shutdown, to 802.1x port [chars]Explanation An attempt was made to assign a private VLAN whose primary VLAN does not exist or is shut down. [dec] is the VLAN, and [chars] is the port.
Recommended Action Make sure the primary VLAN exists and is not shut down. Verify that the private VLAN is associated with a primary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SEC_VLAN_INVALID: Attempt to assign secondary VLAN [dec] to non-PVLAN host 802.1x port [chars]Explanation An attempt was made to assign a secondary VLAN to a port that is not a private VLAN host port, which is not allowed. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the mode of the port so that it is configured as a private VLAN host port, or use a different VLAN that is not configured as a secondary VLAN.
Error Message DOT1X_SWITCH-5-ERR_SPAN_DST_PORT: Attempt to assign VLAN [dec] to 802.1x port [chars], which is configured as a SPAN destinationExplanation An attempt was made to assign a VLAN to an IEEE 802.1x port that is configured as a Switched Port Analyzer (SPAN) destination port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the SPAN configuration so that the port is no longer a SPAN destination port, or change the configuration so that no VLAN is assigned.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_MDA_INACTIVE: Multi-Domain Authentication cannot activate because Data and Voice VLANs are the same on port [chars]Recommended Action Multi-Domain Authentication (MDA) host mode cannot start if the configured data VLAN on a port is the same as the voice VLAN. [chars] is the port.
Recommended Action Change either the voice VLAN or the access VLAN on the interface so that they are not the same. MDA then starts.
Error Message DOT1X_SWITCH-5-ERR_VLAN_EQ_VVLAN: Data VLAN [dec] on port [chars] cannot be equivalent to the Voice VLAN.Explanation An attempt was made to assign a data VLAN to an IEEE 802.1x port that is the same as the voice VLAN. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change either the voice VLAN or the IEEE 802.1x-assigned VLAN on the interface so that they are not the same.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INTERNAL: Attempt to assign internal VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is used internally and cannot be assigned to this port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Assign a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_INVALID: Attempt to assign invalid VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is out of range. [dec] is the VLAN, and [chars] is the port.
Recommended Action Update the configuration to use a valid VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_NOT_FOUND: Attempt to assign non-existent or shutdown VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign a VLAN to an IEEE 802.1x port, but the VLAN was not found in the VLAN Trunking Protocol (VTP) database. [dec] is the VLAN, and [chars] is the port.
Recommended Action Make sure that the VLAN exists and is not shut down, or use another VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_ON_ROUTED_PORT: Dot1x cannot assign a VLAN [dec] to a routed port [chars]Explanation An attempt was made to assign a VLAN to a supplicant on a routed port, which is not allowed. [dec] is the VLAN ID and [chars] is the port.
Recommended Action Either disable the VLAN assignment, or change the port type to a nonrouted port.
Error Message DOT1X_SWITCH-5-ERR_VLAN_PROMISC_PORT: Attempt to assign VLAN [dec] to promiscuous 802.1x port [chars]Explanation An attempt was made to assign a VLAN to a promiscuous IEEE 802.1x port, which is not allowed. [dec] is the VLAN, and [chars] is the port.
Recommended Action Change the port mode so that it is no longer a promiscuous port, or change the configuration so that no VLAN is assigned.
Error Message DOT1X_SWITCH-5-ERR_VLAN_RESERVED: Attempt to assign reserved VLAN [dec] to 802.1x port [chars]Explanation An attempt was made to assign an invalid VLAN to an IEEE 802.1x port. The VLAN specified is a reserved VLAN and cannot be assigned to this port. [dec] is the VLAN, and [chars] is the port.
Recommended Action Assign a different VLAN.
Error Message DOT1X_SWITCH-5-ERR_VLAN_RSPAN: Attempt to assign RSPAN VLAN [dec] to 802.1x port [chars]. 802.1x is incompatible with RSPANExplanation This message means that remote SPAN should not be enabled on a VLAN with IEEE 802.1x-enabled. [dec] is the VLAN, and [chars] is the port.
Recommended Action Either disable remote SPAN configuration on the VLAN, or disable IEEE 802.1x on all the ports in this VLAN.
Related Documentation
These documents provide complete information about the Cisco Catalyst 3120 for HP Blade Switch and are available from this Cisco.com site:
http://www.cisco.com/en/US/products/ps6748/tsd_products_support_series_home.html
•Cisco Catalyst Blade Switch 3000 Series for HP Getting Started Guide
•Regulatory Compliance and Safety Information for the Cisco Catalyst Blade Switch 3000 Series for HP
•Release Notes for the Cisco Catalyst Blade Switch 3120 for HP
Note Before you install, configure, or upgrade the switch module, see the release notes on Cisco.com for the latest information.
•Cisco Catalyst Blade Switch 3120 for HP Software Configuration Guide
•Cisco Catalyst Blade Switch 3120 for HP Command Reference
•Cisco Catalyst Blade Switch 3120 for HP System Message Guide
•Cisco Software Activation Document for HP
•These compatibility matrix documents are available from this Cisco.com site:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
–Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix
–Cisco Small Form-Factor Pluggable Modules Compatibility Matrix
–Compatibility Matrix for 1000BASE-T Small Form-Factor Pluggable Modules
For other information about related products, see these documents on Cisco.com:
•Getting Started with Cisco Network Assistant
•Release Notes for Cisco Network Assistant
•Network Admission Control Software Configuration Guide
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What's New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.
This document is to be used in conjunction with the documents listed in the "Related Documentation" section.
CCDE, CCENT, CCSI, Cisco Eos, Cisco HealthPresence, Cisco IronPort, the Cisco logo, Cisco Lumin, Cisco Nexus, Cisco Nurse Connect, Cisco Pulse, Cisco StackPower, Cisco StadiumVision, Cisco TelePresence, Cisco Unified Computing System, Cisco WebEx, DCE, Flip Channels, Flip for Good, Flip Mino, Flipshare (Design), Flip Ultra, Flip Video, Flip Video (Design), Instant Broadband, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn, Cisco Capital, Cisco Capital (Design), Cisco:Financed (Stylized), Cisco Store, and Flip Gift Card are service marks; and Access Registrar, Aironet, AllTouch, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, Continuum, EtherFast, EtherSwitch, Event Center, Explorer, Fast Step, Follow Me Browsing, FormShare, GainMaker, GigaDrive, HomeLink, iLYNX, Internet Quotient, IOS, iPhone, iQuick Study, IronPort, the IronPort logo, Laser Link, LightStream, Linksys, MediaTone, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, Network Registrar, PCNow, PIX, PowerKEY, PowerPanels, PowerTV, PowerTV (Design), PowerVu, Prisma, ProConnect, ROSA, ScriptShare, SenderBase, SMARTnet, Spectrum Expert, StackWise, The Fastest Way to Increase Your Internet Quotient, TransPath, WebEx, and the WebEx logo are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.