Technical Specifications

Provides router, port, cabling specifications, and power adapters for the device.

Router Specifications

The following information lists the operational limits of the Cisco IR807. Operating the router outside of the limits specified is not supported.

Table 1. Physical Characteristics

Description

Design Specification

Dimensions (H x W x D)

(height x width x depth x) are 1.85" x 5.07" x 4.50" (4.69 x 12.85 x 11.43 cm).

Table 2. Environmental Operating Ranges

Description

Design Specification

Operating Temperature and Altitude

-40° to 140°F (-40° to 60°C) in a sealed NEMA cabinet with no airflow

-40° to 158°F (-40° to 70°C) in a vented cabinet with 40 lfm of air

-40° to 167°F (-40° to 75°C) in a forced air enclosure with 200 lfm of air

(type tested at +85C for 16 hours)

NOTE: This product has been safety certified up to 60C maximum ambient.

-500 to 5,000 feet. Derate max operating temperature 1.5°C per 1000 feet. 10,000 ft maximum

Operating Altitude

13,800 ft. (4206m)

Humidity

5% — 95% non-condensing

Table 3. Environmental Tests

Description

Design Specification

Vibration

IEC 61850-3, IEEE 1613

Shock

Half Sine (operating)

Duration = <2 ms

Velocity = 2.39 m/s

Number of shocks: A series of 6 shocks, one on each side.

IEEE 1613 and IEC61850-3

NUP T2 shock testing, non-NEBS 3396

Table 4. Certifications

Description

Design Specification

Standard Safety Certifications

UL 60950-1, 2nd edition

CAN/CSA C22.2 No. 60950-1, 2nd edition

EN 60950-1, 2nd edition

CB to IEC 60950-1, 2nd edition with all group differences and national deviations

EMC Emissions

EN55022/CISPR22, CFR 47 Part 15, ICES003, VCCI-V-3, AS/NZS CISPR22, CNS13438, EN300- 386, EN61000-3-2, EN61000-3-3, and EN55032/CISPR32

EMC Immunity

EN55024/CISPR24, (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11), EN55035/CISPR35, and EN300-386

Cellular Radio

EN 301 908-1, EN 301 908-2, EN 301 511, and EN 301 908-13

Compliance

IP30 compliant when vertical and cables downward.

Radio Immunity

EN301 489-1, EN 303 413, EN 301 489-19, EN 301 489-52, and EN 62311

Table 5. Transportation/Storage Conditions

Description

Design Specification

Temperature

-40 to +85°C (–40 to +185°F)

Humidity

10 – 95%

Altitude

4570 m (15,000 ft)

Table 6. Router DC Power Adapter

Description

Design Specification

Input Voltage

Nominal voltage: 12V to 48V DC

Absolute: 9.6 to 60V DC input

Maximum Power Consumption

10 Watts

Table 7. Country Marks

Description

Design Specification

Country marks

FCC, CE, BSMI, IC

Table 8. Hazardous Locations

Description

Design Specification

Hazardous Locations

  • ANSI/ISA 12.12.01 (Gas groups A-D)
  • CSA 22.2 No 213 (Gas groups A-D)
  • UL/CSA 60079-0, -15 (Class I, Zone 2, Gas groups IIC)
  • IEC 60079-0, -15 IECEx test report
  • EN 60079-0, -15 ATEX certification (Class I, Zone 2, Gas groups IIC)