Alarms

This chapter provides description, severity, and troubleshooting procedure for each commonly encountered alarm in Cisco Optical Site Manager.

NE-NOT-AUTH-ACCESS

Default Severity: Major (MJ)

Logical Object: Standing

Resource Type: NE

The NE-NOT-AUTH-ACCESS alarm is raised when a XR device has:

  • More than one syslog (configuration) logging or telemetry destination entries.

Clear the NE-NOT-AUTH-ACCESS alarm

The alarm clears when the incorrect Cisco Optical Site Manager syslog (configuration) entries are removed.

Follow these steps to clear the alarm:

Procedure


Step 1

Run the show run command to display the currently active configuration.

Step 2

Check the command output for multiple Cisco Optical Site Manager logging and model-driven telemetry server entries that use port 7514.

The example output highlights the multiple Cisco Optical Site Manager logging and model-driven telemetry in the command output in bold.

RP/0/RP0/CPU0:1014-txp-246#show run          
!! Building configuration...
!! IOS XR Configuration 25.3.1.39I
!! Last configuration change at Mon Sep  8 11:57:24 2025 by cisco
!
hostname 1014
logging 10.1.1.1 vrf default severity all port 7514 source-address 10.1.1.1
logging 10.1.1.11 vrf default severity all port 7514 source-address 10.1.1.11
service timestamps log datetime localtime msec show-timezone year
username cisco
 group root-lr
 group cisco-support
 secret 10 $6$/25p40lFhVIP640.$nyB6.WUJUj2HlEGFwITSFs1l.M9cd40fVq9bk8ENHeGRzPUU56kUXqIWByEDluxNgHa3mmU8WTPlV2KFoc.UA1
!
grpc
!
telemetry model-driven
 include empty values
 destination-group COSM-DESTINATION
  address-family ipv4 10.1.1.1 port 7514
   encoding json
   protocol udp
  !
  destination 10.1.1.1 port 7514
   encoding json
   protocol udp
telemetry model-driven
 include empty values
 destination-group COSM-DESTINATION
  address-family ipv4 10.1.1.11 port 7514
   encoding json
   protocol udp
  !
  destination 10.1.1.11 port 7514
   encoding json
   protocol udp
  !
 !
 sensor-group COSM-FPD-GROUP
  sensor-path Cisco-IOS-XR-show-fpd-loc-ng-oper:show-fpd/locations/location/fpds/fpd/fpd-info-detail/status
 !

Step 3

Run the no logging command to remove the incorrect configuration.

Example:

RP/0/RP0/CPU0:1014(config)#no logging 10.1.1.11 vrf default severity all port 7514 source-address 10.1.1.11

Step 4

Run the no telemetry model-driven to remove the incorrect configuration for model-driven telemetry.

Example:

RP/0/RP0/CPU0(config):1014#no telemetry model-driven destination-group COSM-DESTINATION address-family ipv4 10.1.1.11 port 7514
no telemetry model-driven destination-group COSM-DESTINATION destination 10.1.1.11 port 7514

If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).

SYSBOOT

Default Severity: Major (MJ), Service-Affecting (SA)

Logical Object: NE

The System Reboot alarm indicates that new software is booting on the control card. No action is required to clear the alarm. The alarm clears when all cards finish rebooting the new software. The reboot takes up to 30 minutes. However, if several line cards are present on the nodes in the network or if the line cards reboot many times, the alarm clears before all the line cards reboot completely.

If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).


Note


SYSBOOT is an informational alarm. It only requires troubleshooting if it does not clear.


RAMAN-CALIBRATION-FAILED

Default Severity: Minor (MN), Non-Service-Affecting (NSA)

Logical Object: OTS

The RAMAN-CALIBRATION-FAILED alarm is raised on the EDRA-1-xx, EDRA-2-xx, and RAMAN-CTP cards when automatic Raman pump calibration is failed and will not run again. The alarm indicates insufficient Raman Amplification by customer fibre. The Raman calibration can also fail due to the setup issues that include:
  • Wrong patch-cords or cabling

  • Incorrect ANS

  • Missing communication channel between nodes.

Clear the RAMAN-CALIBRATION-FAILED Alarm

SUMMARY STEPS

  1. Use optical time domain reflectometer (OTDR) to identity any excess loss between the Raman card LINE-RX port and the customer fibre. After the inspection, a new Raman Calibration is triggered and if the physical problem is fixed, the alarm will clear.
  2. If the alarm is caused by a set-up problem, re-verify all node installation steps and manually trigger a Raman Calibration.

DETAILED STEPS


Step 1

Use optical time domain reflectometer (OTDR) to identity any excess loss between the Raman card LINE-RX port and the customer fibre. After the inspection, a new Raman Calibration is triggered and if the physical problem is fixed, the alarm will clear.

Step 2

If the alarm is caused by a set-up problem, re-verify all node installation steps and manually trigger a Raman Calibration.

If the condition does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).