NE-NOT-AUTH-ACCESS
Default Severity: Major (MJ)
Logical Object: Standing
Resource Type: NE
The NE-NOT-AUTH-ACCESS alarm is raised when a XR device has:
-
More than one syslog (configuration) logging or telemetry destination entries.
Clear the NE-NOT-AUTH-ACCESS alarm
The alarm clears when the incorrect Cisco Optical Site Manager syslog (configuration) entries are removed.
Follow these steps to clear the alarm:
Procedure
|
Step 1 |
Run the show run command to display the currently active configuration. |
|
Step 2 |
Check the command output for multiple Cisco Optical Site Manager logging and model-driven telemetry server entries that use port 7514. The example output highlights the multiple Cisco Optical Site Manager logging and model-driven telemetry in the command output in bold.
|
|
Step 3 |
Run the no logging command to remove the incorrect configuration. Example:
|
|
Step 4 |
Run the no telemetry model-driven to remove the incorrect configuration for model-driven telemetry. Example:
|
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/c/en/us/support/index.html for more information or call Cisco TAC (1 800 553-2447).