May 17, 2004
Products Affected
|
Product |
Comments |
|||
|---|---|---|---|---|
|
Cisco MeetingPlace Server 8112 (M3) |
Versions: 5.0.2q, 5.1.0x, and 5.1.1b |
|||
Problem Description
Server restarts with Hardware watchdog timeout after T1 Blue alarms.
09/23 07:50:58 MAJ 0xb007a 0/3, "HWFAULT", 0 (0xe, 0x3, 0xffffffff, 0)
Blue Alarm detected on this T1 span ([14], card 3, [-1], span 0)
09/23 07:53:35 MIN 0x300c5 0/8, "vuisession.cc", 2491 (0x17c, 0x17c, 0x7c0003a, 0x1a0001d)
Bad Session Num. Did the trunks get swapped with calls on them? ...
MAJ 070035 1 Sep 23 08:29 Sep 23 08:29 0 SW MODULE=2 Hardware watchdog timeout
Problem Symptoms
Meeting attendees will get dropped when the server restarts.
Workaround/Solution
WORKAROUND:
None
SOLUTION:
A vui hot fix is available in 5.0.2ab and 5.1.1d. Contact the Cisco Technical Assistance Center to apply this hot fix.
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.