May 19, 2004
Products Affected
|
Product |
Comments |
|---|---|
|
Cisco MeetingPlace Server 8112 (M3) |
5.1.0x |
Problem Description
The Cisco MeetingPlace Server might restart itself if a failed outdial coincides with an internal consistency check. This internal consistency check only occurs when the conference processor software is in an idle state.
Problem Symptoms
All callers will be disconnected from their conferences when the system restarts.
Workaround/Solution
WORKAROUND:
None
SOLUTION:
A 5.1.0ab cpserver hot fix is available. Contact Cisco MeetingPlace Support (TAC) to apply this hot fix. 5.1.0z cptester must also be applied if it has not been previously installed.
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.