May 19, 2004
Products Affected
|
Product |
Comments |
|---|---|
|
Cisco MeetingPlace Server 8112 (M3) |
R5.0.2q and R5.1.0x |
Problem Description
Minor alarm for "0x5244e - DB server connected task not current" is caused by a harmless race condition.
01/23 07:33:54 INFO 0x52455 0/9, "dbcurr.cc", 175 (0x5, 0, 0x3f33, 0)
DB server unable to put currency, status 5, dbn 0
01/23 07:33:54 MIN 0x5244e 0/9, "dbtasks.cc", 614 (0, 0, 0, 0)
DB server connected task not current code 0
Problem Symptoms
System manager gets an unnecessary alarm.
Workaround/Solution
WORKAROUND:
None
SOLUTION:
Downgrade alarm 0x5244e to a warning. Fixed in db hot fix 5.0.2v and above, and, 5.1.0aa and above. Contact Cisco MeetingPlace Support (TAC) to apply the hot fix.
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.