Revised January 31, 2002
October 16, 2000
Products Affected
|
Product |
Comments |
|---|---|
|
IGX-UXM |
Observed only on UXM with E1 or T1 IMA enabled |
|
IGX-UXME |
Observed only on UXME with E1 or T1 IMA enabled |
Problem Description
A trunk failure may result when an Inverse Multiplexing over ATM (IMA) Universal Switching Module (UXM) or Universal Switching Module Enhanced (UXME) clock source or a clock path switches across, or on, an IMA UXM trunk
Background
Each IGX-8400 and BPX-8600 in a WAN Switch network uses a single clock source. This clock source may be derived from a trunk or a line that is connected locally, or one that is connected to a remote node. Also, the clock may be derived from an internal oscillator, or an external clock source, connected to the WAN Switch External Clock input connector
Problem Symptoms
The most common symptom is observed in the event log. Use the display log command and look for IMA or Physical Line failures:
Info Clock switch to oscillator of SCC 03/22/99 10:38:00 Major TRK 14.1 Loss of Cell 03/22/99 10:37:59 Major PHYSLN 14.1 Loss of Cell 03/22/99 10:37:59
In extreme cases, depending on network topology, nodes may be unreachable for up to several minutes. This can be observed using the dsplog or dspalms commands. Below is example output from the dsplog command indicating a communication break:
Minor Comm Break with igx1 03/22/99 10:38:10
Workaround/Solution
Workaround
Inhibit clocking over UXM or UXME IMA trunks by configuring the trunks' Pass Sync parameter to No using the cnftrk slot.port command. Do not configure any IMA trunks as a clock source. This is the recommended resolution if trunks other than IMA trunks are available for passing clock synchronization.
Solution
The solution requires the UXM/UXME firmware version A.A.E or later, and an upgraded System Clock Module of hardware version D or later. The assembly number version of the IGX-SCM cabling is 73-3341-02. Revision X or later of the 73- level is needed, as seen below in the dsppwr command output:
node1 TN StrataCom IGX 8420 9.2.20 May 5 1999 07:31 GMT
Power Supply Status Cabinet Temperature
Monitor Rev AS, Ser # 435857 - Status: Active 27 80
AC Supply Status C 60 | | 140 F
A 1 Present OK e | | a
B 1 Present OK n 50 |--| 122 h
C 1 Empty t | | r
D 2 Empty i 40 | | 104 e
E 2 Empty g | | n
F 2 Empty r 30 | | 86 h
a | | e
d 20 | | 68 i
e `--'' t
Last Command: dsppwr
Note: In the underlined, bolded "AS" above, the second letter indicates that the IGX-SCM 73- level hardware revision is "S". The appropriate revision is "X" or later. In this example, the IGX-SCM cabling should be replaced if the symptoms and conditions discussed in this Field Notice appear. Also note that this SCM hardware revision is required only for networks with UXMs or UXMEs using IMA functionality. Additionally, the IGX-8400 must be powered down to replace the IGX-SCM; therefore, do not recommend replacing this component without first knowing if the firmware is revision A.A.E or later, and whether there are other clocking problems in the network
DDTS
To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.
|
DDTS |
Description |
|---|---|
|
CSCdm18601 |
UXM IMA with T1 backcard logs trunk failures upon clock switch of node |
|
CSCdk56755 |
UXM, IMA Inverse Mux Failure, cannot pass sync |
Physical Replacement of Parts
Submit a return material authorization (RMA) to order any quantities of IGX-SCM= cabling.
For More Information
If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:
Receive Email Notification For New Field Notices
Product Alert Tool - Set up a profile to receive email updates about reliability, safety, network security, and end-of-sale issues for the Cisco products you specify.