Guest

Cisco ONS 15800 Series DWDM Platforms

ONS 15801 Board Alarms

Document ID: 18927



Contents

Introduction
Prerequisites
      Requirements
      Components Used
      Conventions
Blue Band Amplifier (BBA)
External Orderwire Interface (EOI)
Input Output Card (IOC)
Line Service Modem (LSM-W)
Additional Digital Settings
Optical Add Drop Multiplexer (OADM)
Pre-Line amplifier (PRE-L)
Red Band Amplifier (RBA)
Receive Transponder 2.5 Gbps (RXT-DM-M, RXT-DM-N)
Transmit Power Amplifier (TPA) - Blue Band
Transmit Power Amplifier (TPA) - Red Band
Wavelength Converter Module 2.5 & 10 Gbps (WCM-EM-M)
Add Drop Amplifier (ADA)
24WD-R Module
8WD-B Module
SCF Module
Additional Monitored BAY Digital Value
LEM & WCM - 10Gbps Module
Additional Monitored Digital Value
LEM & WCM - 622Mbps Module & LEM 2.5 Gbps Module
Related Information

Introduction

This document provides a list of board alarms for the Cisco Photonics Local Terminal (PLT). It is organized by board, and provides Cisco PLT alarm names, alarm descriptions, and information on whether the situation causing the alarm is service-affecting. It also states whether the alarm is analog or digital (A/D).

This document covers most major boards in Cisco ONS 15801. Some boards have the same alarms so these boards are grouped together in the same list.

Prerequisites

Requirements

There are no specific prerequisites for this document.

Components Used

This document is not restricted to specific software and hardware versions.

Conventions

For more information on document conventions, see the Cisco Technical Tips Conventions.

Blue Band Amplifier (BBA)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp1A*

Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasTemp2A

Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasCurr1A

Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

LasCurr2A

Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

InpPwr1A

Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

NO

YES

OutPwr1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold.

NO

NO

YES

LasPwr1A

Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

LasPwr2A

Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

Las Stat 1D

Laser Operating Status Off: The pump laser has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Site 1D

Site type identification Status: Line / Terminal.

NO

External Orderwire Interface (EOI)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

IsoPowMon1D

Circuit Packet Power Supply StatusOff: Power Supply Voltage Low.

NO

Input Output Card (IOC)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

GenAnalIn1-8A

Generic Analog Input (8) Backplane A-IN connector.

NA

GenDigIn1-32

Generic Digital Input (32) Backplane D-IN connector.

NA

GenDigIn1-20

Generic Digital Output (32) Backplane D-OUT connector.

NA

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or major.

NO

Led Yellow 1D

Card yellow led status Severity Minor

NO

Led White 1D

Card yellow ind led status Severity warning

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

NO

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Line Service Modem (LSM-W)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

ELasTemp1A

East Direction Laser Operating Temperature East Low: Laser Operating Temperature crossed the Low threshold Temp.East High: Laser Operating Temperature crossed the High threshold Temp.

NO

NO

WlasTemp2A

West Direction Laser Operating Temperature West Low: Laser Operating Temperature crossed the Low threshold Temp. West High: Laser Operating Temperature crossed the High threshold Temp.

NO

NO

ELasCurr1A

East Direction Laser Operating bias East Curr.: Laser Bias crossed the High threshold High East Curr.: Laser Bias crossed the Low threshold Low.

NO

NO

WLasCurr2A

West Direction Laser Operating bias West Curr.: Laser Bias crossed the High threshold High West Curr.: Laser Bias crossed the Low threshold Low.

NO

NO

ELasOutPwr1A

Optical Output power in the East direction East Power: Laser Output Power crossed the Low threshold low East Power: Laser Output Power crossed the High thresholdhigh.

NO

NO

WlasOutPwr2A

Optical Output power in the West direction West Power: Laser Output Power crossed the Low threshold low West Power: Laser Output Power crossed the High thresholdhigh.

NO

NO

Cisco PLT Alarm Name

Alarm Description

Service Affecting

ELosRx 1D

Loss of Signal on East Receive side On / Off: Optical Supervisory Channel Loss of Optical Signal.

NO

ELfaRx 1D

Loss of Frame on East Receive side On / Off: Optical Supervisory Channel Loss of Frame.

NO

ERaiRx 1D

Receveid an East Remote Alarm Indication On: OSC RAI.

NO

EAuxPRx 1D

Received an East Auxiliary Pattern On: Forced to Receive the Auxiliary Pattern (Test purpose Only).

NO

EIdle Rx 1D

Loss of Modulation on East Receive side On / Off: Optical Supervisory Channel Loss of Modulation.

NO

WLosRx 2D

Loss of Signal on West Receive side On / Off: Optical Supervisory Channel Loss of Optical Signa.l

NO

WLfaRx 2D

Loss of Frame on West Receive side On / Off: Optical Supervisory Channel Loss of Frame.

NO

WRaiRx 2D

Receveid a West Remote Alarm Indication On: OSC RAI.

NO

WAuxPRx 2D

Received a West Auxiliary Pattern On: Forced to Receive the Auxiliary Pattern(Test purpose Only).

NO

WIdle Rx 2D

Loss of Modulation on West Receive side On / Off: Optical Supervisory Channel Loss of Modulation.

NO

DPR Fail 1D

Dual port RAM Failure On: DPRAM failure.

NO

Cfg Fail 1D

Internal Configuration Failure On: Internal Configuration Failure detected.

NO

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 2D

Card yellow led status Severity Minor.

NO

Led White 3D

Card yellow ind led status Severity warning.

NO

Additional Digital Settings

The information in this section was forced for test purposes only.

Cisco PLT Variable Name

Variable Description

Service Affecting

EMst 1D

East Transmission Master Status On: Forced to Transmit the Master Clock.

NO

WMst 2D

West Transmission Master Status On: Forced to Transmit the Master Clock.

NO

ERaiTx1D

Received an East Remote Alarm Indication On: OSC RAI.

NO

WRaiTx2D

Received a West Remote Alarm Indication On: OSC RAI.

NO

EAuxPTx 1D

East Transmission of Auxiliary Pattern On: Forced to Transmit the Auxiliary Pattern.

NO

WAuxPTx 2D

West Transmission of Auxiliary Pattern On: Forced to Transmit the Auxiliary Pattern.

NO

Optical Add Drop Multiplexer (OADM)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp 1

BGF1 Operating Temperature High Temp: BGF Operating Temperature crossed the Degrade High threshold Low Temp: BGF Operating Temperature crossed the Degrade Low threshold.

NO

NO

LasTemp 2

BGF2 Operating Temperature High Temp: BGF Operating Temperature crossed the Degrade High threshold Low Temp: BGF Operating Temperature crossed the Degrade Low threshold.

NO

NO

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Pre-Line amplifier (PRE-L)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp1A

Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasCurr1A

Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

InpPwr1A

Optical Input Power Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

YES

OutPwrRed1A

Optical Output Power (Red Band) Power Fail: Optical Output Power crossed the Fail Low threshold Power Deg: Optical Output Power crossed the Degrade Low threshold.

YES

NO

OutPwrBlue1A

Optical Output Power (Blue Band) Power Fail: Optical Output Power crossed the Fail Low threshold Power Deg: Optical Output Power crossed the Degrade Low threshold.

YES

NO

LasPwr 1A

Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Service Affecting Power Deg: Laser Power crossed the Degrade Low threshold.

YES

NO

Las Stat 1D

Laser Operating Status Off: The pump laser has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Red Band Amplifier (RBA)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp1A

Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasTemp2A

Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasCurr1A

Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

LasCurr2A

Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

InpPwr1A

Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

NO

YES

OutPwr1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold.

NO

NO

YES

LasPwr1A

Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

LasPwr2A

Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

Las Stat 1D

Laser Operating Status Off: The pump laser has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Site 1D

Site type identification Status: Line / Terminal.

NO

Receive Transponder 2.5 Gbps (RXT-DM-M, RXT-DM-N)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasCur 1A

Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold.

NO

NO

InpPwr 1A

Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold.

NO

NO

OutPwr 1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold.

NO

NO

LasPwr 1A

Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

NO

NO

modin stat 1D

Loss of Input Signal Modulation On: Loss of Input Signal Modulation.

YES

los status 1

Loss of Input Electrical Signal On: Loss of Electrical Signal.

YES

ipoin stat 1

Optical Safety Input Signal On: Optical Safety Input Signal Active.

NO

ipoin stat 1

Optical Safety Output Signal On: Optical Safety Output Signal Active.

NO

ipoin stat 1

External Safety Control On: External Optical Safety Control Active.

YES

pinlowstat 1

Loss of Optical Input Power On: Loss of Optical Input Power.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Transmit Power Amplifier (TPA) - Blue Band

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp1A

Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasTemp2A

Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasCurr1A

Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

LasCurr2A

Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

InpPwr1A

Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

NO

YES

OutPwr1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold.

NO

NO

YES

LasPwr1A

Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

LasPwr2A

Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

Las Stat 1D

Laser Operating Status Off: The pump laser has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Site 1D

Site type identification Status: Line / Terminal.

NO

Transmit Power Amplifier (TPA) - Red Band

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp1A

Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasTemp2A

Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasCurr1A

Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

LasCurr2A

Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

InpPwr1A

Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

NO

YES

OutPwr1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold.

NO

NO

YES

LasPwr1A

Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

LasPwr2A

Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

YES

NO

NO

Las Stat 1D

Laser Operating Status Off: The pump laser has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Site 1D

Site type identification Status: Line / Terminal.

NO

Wavelength Converter Module 2.5 & 10 Gbps (WCM-EM-M)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp 1A

Transponder Laser Operating Temperature Low Temp: Laser Operating Temperature crossed the Fail Low threshold High Temp: Laser Operating Temperature crossed the Fail High threshold.

YES

YES

LasCur 1A

Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold.

NO

NO

InpPwr 1A

Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold.

NO

NO

OutPwr 1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold.

NO

NO

LasPwr 1A

Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

NO

NO

modin stat 1D

Loss of Input Signal Modulation On: Loss of Input Signal Modulation.

Note: Not available on 10Gbps cards.

YES

modout stat 1D

Output Modulation Failure On: Loss of Output Modulation.

YES

los status 1

Loss of Input Electrical Signal On: Loss of Electrical Signal.

Note: Not available on 10Gbps cards without B1 Mon.

YES

ipoin stat 1

Optical Safety Input Signal On: Optical Safety Input Signal Active.

NO

ipout stat 1

Optical Safety Output Signal On: Optical Safety Output Signal Active.

NO

opin stat 1

External Safety Control On: External Optical Safety Control Active.

NO

pinlowstat 1

Loss of Optical Input Power On: Loss of Optical Input Power.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

Add Drop Amplifier (ADA)

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp 1A

Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasTemp 2A

Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold.

NO

NO

LasCurr 1A

Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

LasCurr 2A

Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold.

NO

NO

NO

InpPwr 1A

Optical Input Power 1 High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

NO

YES

InpPwr 2A

Optical Input Power 2 High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold.

NO

NO

YES

OutPwr 1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold.

NO

NO

YES

OutPwr 2A

Optical Output Power 2 High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold.

NO

NO

YES

LasPwr 1A

Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold.

YES

NO

LasPwr 2A

Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold.

YES

NO

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

24WD-R Module

Cisco PLT Alarm Name

Alarm Description

Service Affecting

AwgTemp 1A

AWG Operating Temperature Low Temp: AWG Operating Temperature crossed the Fail Low threshold LMid Temp: AWG Operating Temperature crossed the Degrade Low threshold HMid Temp: AWG Operating Temperature crossed the Degrade High threshold High Temp: AWG Operating Temperature crossed the Fail High threshold.

YES

NO

NO

YES

Status Awg 1A

AWG Operating Temperature Control Status AWG off: AWG Operating Temperature has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

8WD-B Module

Cisco PLT Alarm Name

Alarm Description

Service Affecting

AwgTemp 1A

AWG Operating Temperature Low Temp: AWG Operating Temperature crossed the Fail Low threshold LMid Temp: AWG Operating Temperature crossed the Degrade Low threshold HMid Temp: AWG Operating Temperature crossed the Degrade High threshold High Temp: AWG Operating Temperature crossed the Fail High threshold.

YES

NO

NO

YES

Status Awg 1A

AWG Operating Temperature Control Status AWG off: AWG Operating Temperature has been shut down.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

SCF Module

Cisco PLT Alarm Name

Alarm Description

Service Affecting

FanCurrent 1A

Fan 1 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold.

NO

NO

FanCurrent 2A

Fan 2 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold.

NO

NO

FanCurrent 3A

Fan 3 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold.

NO

NO

FanCurrent 4A

Fan 4 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold.

NO

NO

DC Conv 1A

Fan Power Supply Voltage Power DC Hi: Fan Power Supply Voltage crossed the High threshold Power DC Lo: Fan Power Supply Voltage crossed the Low threshold.

NO

NO

Bat Ctrl 1A

Back-plane Power Supply Voltage Level Battery Hi: Back-plane Power Supply Voltage crossed the High threshold Battery Lo: Back-plane Power Supply Voltage crossed the Low threshold.

NO

NO

Bat status 1D

Battery A Status Bat low Battery Voltage Level Low.

NO

Bat status 2D

Battery B Status Bat low Battery Voltage Level Low.

NO

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Additional Monitored BAY Digital Value

Led Fan 1

Fan 1 Led Status Severity Minor.

NO

Led Fan 2

Fan 2 Led Status Severity Minor.

NO

Led Fan 3

Fan 3 Led Status Severity Minor.

NO

Led Fan 4

Fan 4 Led Status Severity Minor.

NO

Led B-Crit 1

BAY Critical led status Severity Critical.

NO

Led B-Maj 1

BAY Major led status Severity Major.

NO

Led B-Min 1

BAY Minor led status Severity Minor.

NO

Led B-Pow 1

BAY Power led status Severity Critical/Major.

NO

Rel B-Crit 1

Bay Critical alarm Relay contact status Backplane RM connector..

YES

Rel B-Maj 1

Bay Major alarm Relay contact status Backplane RM connector.

YES

Rel B-Min 1

Bay Minor alarm Relay contact status Backplane RM connector.

NO

Rel B-Pow 1

Bay Power alarm Relay contact status Backplane RM connector.

NO

LEM & WCM - 10Gbps Module

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp 1A

Transponder Laser Operating Temperature Low Temp: Laser Operating Temperature crossed the Fail Low threshold High Temp: Laser Operating Temperature crossed the Fail High threshold.

YES

YES

LasCur 1A

Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold.

NO

NO

InpPwr 1A

Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold.

NO

NO

OutPwr 1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold.

NO

NO

LasPwr 1A

Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

NO

NO

modout stat 1D

Output Modulation Failure On: Loss of Output Modulation.

YES

los status 1

Loss of Input Electrical Signal On: Loss of Electrical Signal.

Note: Not available on 10Gbps cards without B1 Mon.

YES

ipoin stat 1

Optical Safety Input Signal On: Optical Safety Input Signal Active.

NO

ipout stat 1

Optical Safety Output Signal On: Optical Safety Output Signal Active.

NO

opin stat 1

External Safety Control On: External Optical Safety Control Active.

YES

pinlowstat 1

Loss of Optical Input Power On: Loss of Optical Input Power.

YES

Additional Monitored Digital Value

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES

LEM & WCM - 622Mbps Module & LEM 2.5 Gbps Module

Cisco PLT Alarm Name

Alarm Description

Service Affecting

LasTemp 1A

Transponder Laser Operating Temperature Low Temp: Laser Operating Temperature crossed the Fail Low threshold High Temp: Laser Operating Temperature crossed the Fail High threshold.

YES

YES

LasCur 1A

Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold.

NO

NO

InpPwr 1A

Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold.

NO

NO

OutPwr 1A

Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold.

NO

NO

LasPwr 1A

Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold.

NO

NO

modout stat 1D

Output Modulation Failure On: Loss of Output Modulation.

YES

los status 1

Loss of Input Electrical Signal On: Loss of Electrical Signal.

Note: Not available on 10Gbps cards without B1 Mon.

YES

ipoin stat 1

Optical Safety Input Signal On: Optical Safety Input Signal Active.

NO

ipout stat 1

Optical Safety Output Signal On: Optical Safety Output Signal Active.

NO

opin stat 1

External Safety Control On: External Optical Safety Control Active.

YES

pinlowstat 1

Loss of Optical Input Power On: Loss of Optical Input Power.

YES

Cisco PLT Variable Name

Variable Description

Service Affecting

Led Red 1D

Card red led status Severity Critical or Major.

NO

Led Yellow 1D

Card yellow led status Severity Minor.

NO

Led White 1D

Card yellow ind led status Severity warning.

NO

Rel. Major 1D

Card major alarm Relay contact status Backplane ALM connector.

YES

Rel. Minor 1D

Card minor alarm Relay contact status Backplane ALM connector.

NO

Rel. LasOffD

Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector.

YES


Related Information



Updated: Sep 16, 2005 Document ID: 18927