Introduction
This document provides a list of board alarms for the Cisco Photonics Local Terminal (PLT). It is organized by board, and provides Cisco PLT alarm names, alarm descriptions, and information on whether the situation causing the alarm is service-affecting. It also states whether the alarm is analog or digital (A/D).
This document covers most major boards in Cisco ONS 15801. Some boards have the same alarms so these boards are grouped together in the same list.
Prerequisites
Requirements
There are no specific prerequisites for this document.
Components Used
This document is not restricted to specific software and hardware versions.
Conventions
For more information on document conventions, see the Cisco Technical Tips Conventions.
Blue Band Amplifier (BBA)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp1A* |
Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasTemp2A |
Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasCurr1A |
Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
LasCurr2A |
Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
InpPwr1A |
Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO NO YES |
|
OutPwr1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold. |
NO NO YES |
|
LasPwr1A |
Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
LasPwr2A |
Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
Las Stat 1D |
Laser Operating Status Off: The pump laser has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
|
Site 1D |
Site type identification Status: Line / Terminal. |
NO |
External Orderwire Interface (EOI)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
IsoPowMon1D |
Circuit Packet Power Supply StatusOff: Power Supply Voltage Low. |
NO |
Input Output Card (IOC)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
GenAnalIn1-8A |
Generic Analog Input (8) Backplane A-IN connector. |
NA |
|
GenDigIn1-32 |
Generic Digital Input (32) Backplane D-IN connector. |
NA |
|
GenDigIn1-20 |
Generic Digital Output (32) Backplane D-OUT connector. |
NA |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
Line Service Modem (LSM-W)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
ELasTemp1A |
East Direction Laser Operating Temperature East Low: Laser Operating Temperature crossed the Low threshold Temp.East High: Laser Operating Temperature crossed the High threshold Temp. |
NO NO |
|
WlasTemp2A |
West Direction Laser Operating Temperature West Low: Laser Operating Temperature crossed the Low threshold Temp. West High: Laser Operating Temperature crossed the High threshold Temp. |
NO NO |
|
ELasCurr1A |
East Direction Laser Operating bias East Curr.: Laser Bias crossed the High threshold High East Curr.: Laser Bias crossed the Low threshold Low. |
NO NO |
|
WLasCurr2A |
West Direction Laser Operating bias West Curr.: Laser Bias crossed the High threshold High West Curr.: Laser Bias crossed the Low threshold Low. |
NO NO |
|
ELasOutPwr1A |
Optical Output power in the East direction East Power: Laser Output Power crossed the Low threshold low East Power: Laser Output Power crossed the High thresholdhigh. |
NO NO |
|
WlasOutPwr2A |
Optical Output power in the West direction West Power: Laser Output Power crossed the Low threshold low West Power: Laser Output Power crossed the High thresholdhigh. |
NO NO |
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
ELosRx 1D |
Loss of Signal on East Receive side On / Off: Optical Supervisory Channel Loss of Optical Signal. |
NO |
|
ELfaRx 1D |
Loss of Frame on East Receive side On / Off: Optical Supervisory Channel Loss of Frame. |
NO |
|
ERaiRx 1D |
Receveid an East Remote Alarm Indication On: OSC RAI. |
NO |
|
EAuxPRx 1D |
Received an East Auxiliary Pattern On: Forced to Receive the Auxiliary Pattern (Test purpose Only). |
NO |
|
EIdle Rx 1D |
Loss of Modulation on East Receive side On / Off: Optical Supervisory Channel Loss of Modulation. |
NO |
|
WLosRx 2D |
Loss of Signal on West Receive side On / Off: Optical Supervisory Channel Loss of Optical Signa.l |
NO |
|
WLfaRx 2D |
Loss of Frame on West Receive side On / Off: Optical Supervisory Channel Loss of Frame. |
NO |
|
WRaiRx 2D |
Receveid a West Remote Alarm Indication On: OSC RAI. |
NO |
|
WAuxPRx 2D |
Received a West Auxiliary Pattern On: Forced to Receive the Auxiliary Pattern(Test purpose Only). |
NO |
|
WIdle Rx 2D |
Loss of Modulation on West Receive side On / Off: Optical Supervisory Channel Loss of Modulation. |
NO |
|
DPR Fail 1D |
Dual port RAM Failure On: DPRAM failure. |
NO |
|
Cfg Fail 1D |
Internal Configuration Failure On: Internal Configuration Failure detected. |
NO |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 2D |
Card yellow led status Severity Minor. |
NO |
|
Led White 3D |
Card yellow ind led status Severity warning. |
NO |
Additional Digital Settings
The information in this section was forced for test purposes only.
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
EMst 1D |
East Transmission Master Status On: Forced to Transmit the Master Clock. |
NO |
|
WMst 2D |
West Transmission Master Status On: Forced to Transmit the Master Clock. |
NO |
|
ERaiTx1D |
Received an East Remote Alarm Indication On: OSC RAI. |
NO |
|
WRaiTx2D |
Received a West Remote Alarm Indication On: OSC RAI. |
NO |
|
EAuxPTx 1D |
East Transmission of Auxiliary Pattern On: Forced to Transmit the Auxiliary Pattern. |
NO |
|
WAuxPTx 2D |
West Transmission of Auxiliary Pattern On: Forced to Transmit the Auxiliary Pattern. |
NO |
Optical Add Drop Multiplexer (OADM)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp 1 |
BGF1 Operating Temperature High Temp: BGF Operating Temperature crossed the Degrade High threshold Low Temp: BGF Operating Temperature crossed the Degrade Low threshold. |
NO NO |
|
LasTemp 2 |
BGF2 Operating Temperature High Temp: BGF Operating Temperature crossed the Degrade High threshold Low Temp: BGF Operating Temperature crossed the Degrade Low threshold. |
NO NO |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
Pre-Line amplifier (PRE-L)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp1A |
Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasCurr1A |
Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
InpPwr1A |
Optical Input Power Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO YES |
|
OutPwrRed1A |
Optical Output Power (Red Band) Power Fail: Optical Output Power crossed the Fail Low threshold Power Deg: Optical Output Power crossed the Degrade Low threshold. |
YES NO |
|
OutPwrBlue1A |
Optical Output Power (Blue Band) Power Fail: Optical Output Power crossed the Fail Low threshold Power Deg: Optical Output Power crossed the Degrade Low threshold. |
YES NO |
|
LasPwr 1A |
Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Service Affecting Power Deg: Laser Power crossed the Degrade Low threshold. |
YES NO |
|
Las Stat 1D |
Laser Operating Status Off: The pump laser has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
Red Band Amplifier (RBA)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp1A |
Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasTemp2A |
Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasCurr1A |
Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
LasCurr2A |
Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
InpPwr1A |
Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO NO YES |
|
OutPwr1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold. |
NO NO YES |
|
LasPwr1A |
Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
LasPwr2A |
Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
Las Stat 1D |
Laser Operating Status Off: The pump laser has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
|
Site 1D |
Site type identification Status: Line / Terminal. |
NO |
Receive Transponder 2.5 Gbps (RXT-DM-M, RXT-DM-N)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasCur 1A |
Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold. |
NO NO |
|
InpPwr 1A |
Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold. |
NO NO |
|
OutPwr 1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold. |
NO NO |
|
LasPwr 1A |
Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
NO NO |
|
modin stat 1D |
Loss of Input Signal Modulation On: Loss of Input Signal Modulation. |
YES |
|
los status 1 |
Loss of Input Electrical Signal On: Loss of Electrical Signal. |
YES |
|
ipoin stat 1 |
Optical Safety Input Signal On: Optical Safety Input Signal Active. |
NO |
|
ipoin stat 1 |
Optical Safety Output Signal On: Optical Safety Output Signal Active. |
NO |
|
ipoin stat 1 |
External Safety Control On: External Optical Safety Control Active. |
YES |
|
pinlowstat 1 |
Loss of Optical Input Power On: Loss of Optical Input Power. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
Transmit Power Amplifier (TPA) - Blue Band
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp1A |
Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasTemp2A |
Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasCurr1A |
Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
LasCurr2A |
Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
InpPwr1A |
Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO NO YES |
|
OutPwr1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold. |
NO NO YES |
|
LasPwr1A |
Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
LasPwr2A |
Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
Las Stat 1D |
Laser Operating Status Off: The pump laser has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
|
Site 1D |
Site type identification Status: Line / Terminal. |
NO |
Transmit Power Amplifier (TPA) - Red Band
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp1A |
Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasTemp2A |
Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasCurr1A |
Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
LasCurr2A |
Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
InpPwr1A |
Optical Input Power High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO NO YES |
|
OutPwr1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold. |
NO NO YES |
|
LasPwr1A |
Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
LasPwr2A |
Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
YES NO NO |
|
Las Stat 1D |
Laser Operating Status Off: The pump laser has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
|
Site 1D |
Site type identification Status: Line / Terminal. |
NO |
Wavelength Converter Module 2.5 & 10 Gbps (WCM-EM-M)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp 1A |
Transponder Laser Operating Temperature Low Temp: Laser Operating Temperature crossed the Fail Low threshold High Temp: Laser Operating Temperature crossed the Fail High threshold. |
YES YES |
|
LasCur 1A |
Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold. |
NO NO |
|
InpPwr 1A |
Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold. |
NO NO |
|
OutPwr 1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold. |
NO NO |
|
LasPwr 1A |
Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
NO NO |
|
modin stat 1D |
Loss of Input Signal Modulation On: Loss of Input Signal Modulation. Note: Not available on 10Gbps cards. |
YES |
|
modout stat 1D |
Output Modulation Failure On: Loss of Output Modulation. |
YES |
|
los status 1 |
Loss of Input Electrical Signal On: Loss of Electrical Signal. Note: Not available on 10Gbps cards without B1 Mon. |
YES |
|
ipoin stat 1 |
Optical Safety Input Signal On: Optical Safety Input Signal Active. |
NO |
|
ipout stat 1 |
Optical Safety Output Signal On: Optical Safety Output Signal Active. |
NO |
|
opin stat 1 |
External Safety Control On: External Optical Safety Control Active. |
NO |
|
pinlowstat 1 |
Loss of Optical Input Power On: Loss of Optical Input Power. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
Add Drop Amplifier (ADA)
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp 1A |
Pump Laser 1 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasTemp 2A |
Pump Laser 2 Operating Temperature High Temp: Laser Operating Temperature crossed the High threshold Low Temp: Laser Operating Temperature crossed the Low threshold. |
NO NO |
|
LasCurr 1A |
Pump Laser 1 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
LasCurr 2A |
Pump Laser 2 Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold Low: Laser Bias crossed the Degrade Low threshold. |
NO NO NO |
|
InpPwr 1A |
Optical Input Power 1 High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO NO YES |
|
InpPwr 2A |
Optical Input Power 2 High: Optical Input Power crossed the Degrade High threshold Power Deg: Optical Input Power crossed the Degrade Low threshold Power Fail: Optical Input Power crossed the Fail Low threshold. |
NO NO YES |
|
OutPwr 1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold. |
NO NO YES |
|
OutPwr 2A |
Optical Output Power 2 High: Optical Output Power crossed the Degrade High threshold Power Deg: Optical Output Power crossed the Degrade Low threshold Power Fail: Optical Output Power crossed the Fail Low threshold. |
NO NO YES |
|
LasPwr 1A |
Pump Laser 1 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold. |
YES NO |
|
LasPwr 2A |
Pump Laser 2 Operating Power Power Fail: Laser Power crossed the Fail Low threshold Power Deg: Laser Power crossed the Degrade Low threshold. |
YES NO |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
24WD-R Module
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
AwgTemp 1A |
AWG Operating Temperature Low Temp: AWG Operating Temperature crossed the Fail Low threshold LMid Temp: AWG Operating Temperature crossed the Degrade Low threshold HMid Temp: AWG Operating Temperature crossed the Degrade High threshold High Temp: AWG Operating Temperature crossed the Fail High threshold. |
YES NO NO YES |
|
Status Awg 1A |
AWG Operating Temperature Control Status AWG off: AWG Operating Temperature has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
8WD-B Module
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
AwgTemp 1A |
AWG Operating Temperature Low Temp: AWG Operating Temperature crossed the Fail Low threshold LMid Temp: AWG Operating Temperature crossed the Degrade Low threshold HMid Temp: AWG Operating Temperature crossed the Degrade High threshold High Temp: AWG Operating Temperature crossed the Fail High threshold. |
YES NO NO YES |
|
Status Awg 1A |
AWG Operating Temperature Control Status AWG off: AWG Operating Temperature has been shut down. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
SCF Module
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
FanCurrent 1A |
Fan 1 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold. |
NO NO |
|
FanCurrent 2A |
Fan 2 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold. |
NO NO |
|
FanCurrent 3A |
Fan 3 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold. |
NO NO |
|
FanCurrent 4A |
Fan 4 Operating Current Current Hi: Fan Operating Current crossed the High threshold Current Lo: Fan Operating Current crossed the Low threshold. |
NO NO |
|
DC Conv 1A |
Fan Power Supply Voltage Power DC Hi: Fan Power Supply Voltage crossed the High threshold Power DC Lo: Fan Power Supply Voltage crossed the Low threshold. |
NO NO |
|
Bat Ctrl 1A |
Back-plane Power Supply Voltage Level Battery Hi: Back-plane Power Supply Voltage crossed the High threshold Battery Lo: Back-plane Power Supply Voltage crossed the Low threshold. |
NO NO |
|
Bat status 1D |
Battery A Status Bat low Battery Voltage Level Low. |
NO |
|
Bat status 2D |
Battery B Status Bat low Battery Voltage Level Low. |
NO |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
Additional Monitored BAY Digital Value
|
Led Fan 1 |
Fan 1 Led Status Severity Minor. |
NO |
|
Led Fan 2 |
Fan 2 Led Status Severity Minor. |
NO |
|
Led Fan 3 |
Fan 3 Led Status Severity Minor. |
NO |
|
Led Fan 4 |
Fan 4 Led Status Severity Minor. |
NO |
|
Led B-Crit 1 |
BAY Critical led status Severity Critical. |
NO |
|
Led B-Maj 1 |
BAY Major led status Severity Major. |
NO |
|
Led B-Min 1 |
BAY Minor led status Severity Minor. |
NO |
|
Led B-Pow 1 |
BAY Power led status Severity Critical/Major. |
NO |
|
Rel B-Crit 1 |
Bay Critical alarm Relay contact status Backplane RM connector.. |
YES |
|
Rel B-Maj 1 |
Bay Major alarm Relay contact status Backplane RM connector. |
YES |
|
Rel B-Min 1 |
Bay Minor alarm Relay contact status Backplane RM connector. |
NO |
|
Rel B-Pow 1 |
Bay Power alarm Relay contact status Backplane RM connector. |
NO |
LEM & WCM - 10Gbps Module
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp 1A |
Transponder Laser Operating Temperature Low Temp: Laser Operating Temperature crossed the Fail Low threshold High Temp: Laser Operating Temperature crossed the Fail High threshold. |
YES YES |
|
LasCur 1A |
Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold. |
NO NO |
|
InpPwr 1A |
Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold. |
NO NO |
|
OutPwr 1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold. |
NO NO |
|
LasPwr 1A |
Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
NO NO |
|
modout stat 1D |
Output Modulation Failure On: Loss of Output Modulation. |
YES |
|
los status 1 |
Loss of Input Electrical Signal On: Loss of Electrical Signal. Note: Not available on 10Gbps cards without B1 Mon. |
YES |
|
ipoin stat 1 |
Optical Safety Input Signal On: Optical Safety Input Signal Active. |
NO |
|
ipout stat 1 |
Optical Safety Output Signal On: Optical Safety Output Signal Active. |
NO |
|
opin stat 1 |
External Safety Control On: External Optical Safety Control Active. |
YES |
|
pinlowstat 1 |
Loss of Optical Input Power On: Loss of Optical Input Power. |
YES |
Additional Monitored Digital Value
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
LEM & WCM - 622Mbps Module & LEM 2.5 Gbps Module
|
Cisco PLT Alarm Name |
Alarm Description |
Service Affecting |
|---|---|---|
|
LasTemp 1A |
Transponder Laser Operating Temperature Low Temp: Laser Operating Temperature crossed the Fail Low threshold High Temp: Laser Operating Temperature crossed the Fail High threshold. |
YES YES |
|
LasCur 1A |
Transponder Laser Operating Bias Degrade: Laser Bias crossed the Degrade High threshold Fail: Laser Bias crossed the Fail High threshold. |
NO NO |
|
InpPwr 1A |
Optical Input Power Power low: Optical Input Power crossed the Fail Low threshold Power high: Optical Input Power crossed the Fail High threshold. |
NO NO |
|
OutPwr 1A |
Optical Output Power High: Optical Output Power crossed the Degrade High threshold Low: Optical Output Power crossed the Degrade Low threshold. |
NO NO |
|
LasPwr 1A |
Transponder Laser Operating Power Power Low: Laser Power crossed the Degrade Low threshold High: Laser Power crossed the Degrade High threshold. |
NO NO |
|
modout stat 1D |
Output Modulation Failure On: Loss of Output Modulation. |
YES |
|
los status 1 |
Loss of Input Electrical Signal On: Loss of Electrical Signal. Note: Not available on 10Gbps cards without B1 Mon. |
YES |
|
ipoin stat 1 |
Optical Safety Input Signal On: Optical Safety Input Signal Active. |
NO |
|
ipout stat 1 |
Optical Safety Output Signal On: Optical Safety Output Signal Active. |
NO |
|
opin stat 1 |
External Safety Control On: External Optical Safety Control Active. |
YES |
|
pinlowstat 1 |
Loss of Optical Input Power On: Loss of Optical Input Power. |
YES |
|
Cisco PLT Variable Name |
Variable Description |
Service Affecting |
|---|---|---|
|
Led Red 1D |
Card red led status Severity Critical or Major. |
NO |
|
Led Yellow 1D |
Card yellow led status Severity Minor. |
NO |
|
Led White 1D |
Card yellow ind led status Severity warning. |
NO |
|
Rel. Major 1D |
Card major alarm Relay contact status Backplane ALM connector. |
YES |
|
Rel. Minor 1D |
Card minor alarm Relay contact status Backplane ALM connector. |
NO |
|
Rel. LasOffD |
Monitor of the optical protection function (laser shutdown) Backplane OP-I/O connector. |
YES |
Related Information