Note The maximum power setting varies according to individual country regulations.
Operating frequency
802.11a
5.15 to 5.25 GHz in the UNII 1 band* 5.25 to 5.35 GHz in the UNII 2 band* 5.470 to 5.725 GHz in the European band 5.725 to 5.825 GHz in the UNII 3 band* *Depending on the regulatory domain in which the client adapter is used
802.11b/g
2.400 to 2.497 GHz (depending on the regulatory domain in which the client adapter is used)
Usable channels
802.11a
5170 to 5320 MHz, 5500 to 5700 MHz, and 5745 to 5805 MHz
Indoor (typical) Outdoor (typical) 500 ft (152 m) @ 6 Mbps 950 ft (290 m) @ 6 Mbps 400 ft (122 m) @ 18 Mbps 800 ft (244 m) @ 18 Mbps 90 ft (27 m) @ 54 Mbps 170 ft (52 m) @ 54 Mbps
Note The above range numbers assume that the client adapter is being used at maximum transmit power with a Cisco Aironet 1232AG Access Point with a 3.5-dBi dipole antenna. Different range characteristics are likely when using the client adapter with a different access point or a Cisco Aironet 1200 Series Access Point with a different antenna.
802.11b/g
Indoor (typical) Outdoor (typical) 410 ft (125 m) @ 1 Mbps 700 ft (213 m) @ 1 Mbps 300 ft (91 m) @ 6 Mbps 650 ft (198 m) @ 6 Mbps 220 ft (67 m) @ 11 Mbps 490 ft (149 m) @ 11 Mbps 180 ft (55 m) @ 18 Mbps 400 ft (122 m) @ 18 Mbps 90 ft (27 m) @ 54 Mbps 110 ft (34 m) @ 54 Mbps
Note The above range numbers assume that the client adapter is being used at maximum transmit power with a Cisco Aironet 1232AG Access Point with a 2.2-dBi dipole antenna. Different range characteristics are likely when using the client adapter with a different access point or a Cisco Aironet 1200 Series Access Point with a different antenna.
1-dBi dual-band 2.4/5-GHz antenna, permanently attached by 6.6-ft (2-m) cable
Power Specifications
Operational voltage
3.3 V (± 0.3 V)
Receive current steady state
802.11a
318 mA maximum
802.11b
327 mA maximum
802.11g
282 mA maximum
Transmit current steady state
802.11a
554 mA maximum
802.11b
539 mA maximum
802.11g
530 mA maximum
Sleep mode steady state
203 mA average
Safety and Regulatory Compliance Specifications
Safety
Designed to meet:
•UL 60950
•CSA 22.2 No. 60950
•IEC 60950 Second Ed., including Amendments 1-4 with all national deviations
•EN 60950 Second Ed., including Amendments 1-4
EMI and susceptibility
FCC Part 15.107 & 15.109 Class B ICES-003 Class B (Canada) VCCI (Japan) EN 301.489-1 and EN-301.489-17 (Europe)
Radio approvals
FCC Part 15.247 FCC Part 15.401-15.407 Canada RSS-210 Europe EN-300.328, EN-301.893 ARIB STD-33, ARIB STD-66, ARIB STD-T71 (Japan) AS 4268.2 (Australia) AS/NZS 3548 (Australia and New Zealand)