Cisco Aironet 1300 Series Wireless Outdoor Access Point/Bridge Hardware Installation Guide, OL-5048-06
Access Point Specifications

Table Of Contents

Access Point Specifications


Access Point Specifications


This appendix provides technical specifications for the access point/bridge, power injector, and power module. Table C-1 lists the technical specifications.

Table C-1 Access Point, Power Injector, and Power Module Specifications 

Category
Access Point
Power Injector and Power Module

Size

Integrated antenna configuration:

8.00 in. W x 8.10 in. H 2.62 in. D
(20.32 cm W x 20.57 cm H 6.66 cm D)

Power injector:

4.62 in. W x 4.76 in. H x 1.07 in. D
(11.74 cm W x 12.09 cm H x 2.72 cm D)

Power module:

3.88 in. L x 1.24 in. W x 2.17 in. D
(98.5 mm L x 31.4 mm W x 55.0 mm D)

LEDs

Four LEDs on the back panel: Radio (R), Ethernet (E), Status (S), and Install (I).

One bi-color power LED on the side panel

Connectors

Bottom panel (left to right): Power injector dual-coax ports (two F-type connectors) and two reverse-TNC antenna connectors

Side panel (left to right): Two coaxial uplink F-type connectors, 48-VDC power connector, RJ-45 connector for 100BASE-T Ethernet, and a RJ-45 serial console port connector

Operating temperature

-22 to 131oF (-30 to 55oC)

Power injector:

-22 to 131oF (-30 to 55oC)

Power module:

32 to 104oF (0 to 40oC)

Non-operational temperature

-40 to 185oF (-40 to 85oC)

Power injector:

-40 to 185oF (-40 to 85oC))

Power module:

-40 to 185oF (-40 to 85oC)
(10,000 ft. limit)

Humidity

0 to 90% (condensing)

Power injector:

0 to 90% (non-condensing)

Power module:

0 to 95% (non-condensing)

Operational vibration

SAE J1455

Power injector—SAE J1455

Non-operational vibration

SAE J1455

Power injector—SAE J1455

Environmental testing compliance

The enclosure has been successfully tested and is in compliance with a NEMA 4 enclosure rating.

Weight

2.5 lbs (1.13 kg)

Power injector—0.8 lbs (0.36 kg)
Power module—1.0 lbs (0.5 kg)

Input voltage

48 VDC (nominal)
53 VDC (maximum)

Power injector (nominal):

48 VDC (LR2 power injector)
12 to 40 VDC (LR2T power injector)

Power module:

100 to 240 VAC

Power consumption

13W (typical)

Radio output power

For autonomous access points/bridges:

100, 50, 30, 20, 10, 5, or 1 mW
(at 1, 2, 5.5, and 11 Mbps)

30, 20, 10, 5, or 1 mW
(at 6, 9, 12, 18, 24, 48, and 54 Mbps)

For lightweight access points:

100, 50, 25, 12, 6, 3, 2, or 1 mW
(at 1, 2, 5.5, and 11 Mbps)

30, 15, 8, 4, 2, or 1 mW
(at 6, 9, 12, 18, 24, 48, and 54 Mbps)

(Depending on the regulatory domain in which the access point/bridge is installed)

Power injector:

18W (maximum at 48 VDC) supplied to the access point/bridge through dual-coax cables

Power module:

18W (maximum at 48 VDC)

Frequency

2.400 to 2.497 GHz
(Depending on the regulatory domain in which the access point/bridge is installed)

Modulation

IEEE 802.11b-compliant radio:

Direct Sequence Spread Spectrum (DSSS)
Complementary Code Keying (CCK)

IEEE 802.11g-compliant radio:

Orthogonal Frequency Division Multiplex (OFDM)

Subcarrier modulation

CCK (5.5 Mbps and 11 Mbps)
BPSK (1 Mbps, 6 Mbps and 9 Mbps)
QPSK (2 Mbps, 12 Mbps and 18 Mbps)
16-QAM (24 Mbps and 36 Mbps)
64-QAM (48 Mbps and 54 Mbps)

Data rates

IEEE 802.11b/g-compliant radio:

1, 2, 5.5 and 11 Mbps

6, 9, 12, 18, 24, 48, and 54 Mbps

(Depending on the regulatory domain in which the access point/bridge is installed)

Non-overlapping channels

3

Antenna

Integrated antenna

13-dBi patch array

Some external antennas:

5.2-dBi omnidirectional
12-dBi omnidirectional
9-dBi patch
10-dBi yagi
13.5-dBi yagi
14-dBi sector
21-dBi dish

(Depending on the regulatory region)

Environmental air space

The access point/bridge and power injector provide adequate fire resistance and low smoke-producing characteristics suitable for operation in a building's environmental air space, such as above suspended ceilings, in accordance with Section 300-22(C) of the National Electrical Code (NEC) and Sections 2-128, 12-010(3) and 12-100 of the Canadian Electrical Code, Part 1, C22.1.


Caution The power module is not tested to UL 2043 and should not be placed in a building's air-handling spaces, such as above suspended ceilings.

Safety

UL 60950
UL 2043
CSA C22.2 No. 60950
IEC 60950
EN 60950

Power injector:

UL 2043

Power injector and power module:

UL 60950
CSA C22.2 No. 60950
IEC 60950
EN 60950

Note The power injector and power module must be used in an indoor environment.

Electromagnetic Compatibility (EMC)

FCC Part 15.107 and 15.109 Class B
ICES-003 Class B (Canada)
EN 55022 Class B
EN 55024
EN 60601-1-2:2001
AS/NZS 3548 Class B
VCCI Class B
EN 301.489-1
EN 301.489-17

FCC Part 15.107 and 15.109 Class B
ICES-003 Class B (Canada)
EN 55022 Class B
EN 55024

Radio type approvals

FCC Parts 15.247, 15.205, 15.209
FCC Bulletin OET-65C
Canada RSS-102, and RSS-210
Japan ARIB-STD-33B
Japan ARIB-STD-66
Europe EN 300.328