Cisco Redundant Power System 2300 Hardware Installation Guide, January 2007
Technical Specifications

Table Of Contents

Technical Specifications


Technical Specifications


This appendix includes the technical specifications and agency approvals for the RPS 2300.

Table A-1 RPS 2300 Environmental and Physical Specifications  

Environmental Ranges

Operating temperature

23-113°F (-5 to 45°C)

Storage temperature

-40-158°F (-40 to 70°C)

Relative humidity

Operating and nonoperating: 0 to 95% (noncondensing)

Operating altitude

Up to 10,000 ft. (3000 m)

Storage altitude

Up to 15,000 ft. (4570 m)

Physical Specifications

Dimensions (H x W x D)

 

Without power supply modules

1.75 x 17.5 x 17.15 in.
(4.5 x 44.5 x 43.6 cm)
10.8 lb. (4.9 kg)

With one C3K-PWR-1150W AC power supply module

1.75 x 17.5 x 20.6 in.
(4.5 x 44.5 x 52.4.6 cm)
16.4 lb. (7.4 kg)

With two C3K-PWR-1150W AC power supply modules

1.75 x 17.5 x 20.6 in.
(4.5 x 44.5 x 52.4.6 cm)
22 lb. (10 kg)

With one C3K-PWR-750W AC power supply module

1.75 x 1.75 x 17.15 in.
(4.5 x 44.5 x 43.6 cm)
14.7 lb. (6.7 kg)

With two C3K-PWR-750W AC power supply modules

1.75 x 1.75 x 17.15 in.
(4.5 x 44.5 x 43.6 cm)
18.6 lb. (8.5 kg)


Table A-2 AC-Power Supply Specifications

Description
C3K-PWR-1150WAC
C3K-PWR-750WAC

Maximum output power

1150 W

750 W

Input voltage range and frequency

115-240 VAC
50-60 Hz

100-240 VAC
50-60 Hz

Input current

12-6 A

10-5 A

Output ratings

12 V @ 25 A
-52 V @16.4 A

12 V @ 25 A
-52 V @ 8.7 A

Total input BTU

4600 Btus per hour, 1350 W

3000 Btus per hour, 880 W

Power supply
input receptacles


IEC60320-C13


IEC60320-C13

Power cord rating

15 A

15 A


Table A-3 DC-Output Power Supply Specifications  

RPS 2300 Power Supply Configuration
DC Output Power
 
12 VDC (W)

-52 VDC (W)

1 x C3K-PWR-750WAC

252W (21 A)

416W (8 A)

2 x C3K-PWR-750WAC

540W (45 A)

832W (16 A)

1 x C3K-PWR-1150WAC

252W (21 A)

800W (15.4 A)

2 x C3K-PWR-1150WAC

540 W (45 A)

1600 W (30.8 A)

Note The maximum 12V power per RPS port is 300W. The maximum -52V power per RPS port is 800W.


Table A-4 RPS 2300 Heat Dissipation Specifications

RPS 2300 Power Supply Configuration
Heat Dissipation Specification
 
No Load (Btus per hour)
Full Load (Btus per hour)

1 x C3K-PWR-750WAC

198

724

2 x C3K-PWR-750WAC

198

1299

1 x C3K-PWR-1150WAC

198

1056

2 x C3K-PWR-1150WAC

221

1963


Table A-5 RPS 2300 Safety Approvals

Safety
EMC

UL 60950-1 First Edition

FCC Part 15 Class A

CAN/CSA 22.2 No. 60950-1 First Edition

EN 55022 (CISPR22)

TUV/GS to EN 60950-1 First Edition

EN 55024 (CISPR24)

IEC 60950-1/EN 60950-1

VCCI Class A

AS/NZS 60950.1

AS/NZS CISPR22 Class A

CE Marking

CE

CLEI code

MIC

CCC approval pending

GOST

NOM approval pending

China EMC Certifications