Table A-1 RPS 2300 Environmental and Physical Specifications  

Environmental Ranges

Operating temperature

23-113°F (-5 to 45°C)

Storage temperature

-40-158°F (-40 to 70°C)

Relative humidity

Operating and nonoperating: 0 to 95% (noncondensing)

Operating altitude

Up to 10,000 ft. (3000 m)

Storage altitude

Up to 15,000 ft. (4570 m)

Physical Specifications

Dimensions (H x W x D)

 

Without power supply modules

1.75 x 17.5 x 17.15 in.
(4.5 x 44.5 x 43.6 cm)
10.8 lb. (4.9 kg)

With one C3K-PWR-1150W AC power supply module

1.75 x 17.5 x 20.6 in.
(4.5 x 44.5 x 52.4.6 cm)
16.4 lb. (7.4 kg)

With two C3K-PWR-1150W AC power supply modules

1.75 x 17.5 x 20.6 in.
(4.5 x 44.5 x 52.4.6 cm)
22 lb. (10 kg)

With one C3K-PWR-750W AC power supply module

1.75 x 1.75 x 17.15 in.
(4.5 x 44.5 x 43.6 cm)
14.7 lb. (6.7 kg)

With two C3K-PWR-750W AC power supply modules

1.75 x 1.75 x 17.15 in.
(4.5 x 44.5 x 43.6 cm)
18.6 lb. (8.5 kg)


Table A-2 AC-Power Supply Specifications

Description
C3K-PWR-1150WAC
C3K-PWR-750WAC

Maximum output power

1150 W

750 W

Input voltage range and frequency

115-240 VAC
50-60 Hz

100-240 VAC
50-60 Hz

Input current

12-6 A

10-5 A

Output ratings

12 V @ 25 A
-52 V @16.4 A

12 V @ 25 A
-52 V @ 8.7 A

Total input BTU

4600 Btus per hour, 1350 W

3000 Btus per hour, 880 W

Power supply
input receptacles


IEC60320-C13


IEC60320-C13

Power cord rating

15 A

15 A


Table A-3 DC-Output Power Supply Specifications  

RPS 2300 Power Supply Configuration
DC Output Power
 
12 VDC (W)

-52 VDC (W)

1 x C3K-PWR-750WAC

252W (21 A)

416W (8 A)

2 x C3K-PWR-750WAC

540W (45 A)

832W (16 A)

1 x C3K-PWR-1150WAC

252W (21 A)

800W (15.4 A)

2 x C3K-PWR-1150WAC

540 W (45 A)

1600 W (30.8 A)

Note The maximum 12V power per RPS port is 300W. The maximum -52V power per RPS port is 800W.


Table A-4 RPS 2300 Heat Dissipation Specifications

RPS 2300 Power Supply Configuration
Heat Dissipation Specification
 
No Load (Btus per hour)
Full Load (Btus per hour)

1 x C3K-PWR-750WAC

198

724

2 x C3K-PWR-750WAC

198

1299

1 x C3K-PWR-1150WAC

198

1056

2 x C3K-PWR-1150WAC

221

1963


Table A-5 RPS 2300 Safety Approvals

Safety
EMC

UL 60950-1 First Edition

FCC Part 15 Class A

CAN/CSA 22.2 No. 60950-1 First Edition

EN 55022 (CISPR22)

TUV/GS to EN 60950-1 First Edition

EN 55024 (CISPR24)

IEC 60950-1/EN 60950-1

VCCI Class A

AS/NZS 60950.1

AS/NZS CISPR22 Class A

CE Marking

CE

CLEI code

MIC

CCC approval pending

GOST

NOM approval pending