Table Of Contents
Connector and Cable Specifications
Connector Specifications
10/100 and 10/100/1000 Ports
100BASE-FX Ports
SFP Module Ports
XENPAK Module Ports (Catalyst 3750G-16TD Switch)
Console Port
Cable and Adapter Specifications
SFP Module Cable Specifications
Two Twisted-Pair Cable Pinouts
Four Twisted-Pair Cable Pinouts for 10/100 Ports
Identifying a Crossover Cable
Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports
Crossover Cable and Adapter Pinouts
Connector and Cable Specifications
This appendix describes the Catalyst 3750 switch ports and the cables and adapters that you use to connect the switch to other devices. This appendix includes these sections:
•
"Connector Specifications" section
•
"Cable and Adapter Specifications" section
Connector Specifications
These sections describe the connectors used with the Catalyst 3750 switches:
•
"10/100 and 10/100/1000 Ports" section
•
"100BASE-FX Ports" section
•
"SFP Module Ports" section
•
"XENPAK Module Ports (Catalyst 3750G-16TD Switch)" section
•
"Console Port" section
10/100 and 10/100/1000 Ports
The 10/100 and 10/100/1000 Ethernet ports on Catalyst 3750 switches use standard RJ-45 connectors and Ethernet pinouts with internal crossovers. Figure B-2 and Figure B-1 show the pinouts.
Figure B-1 10/100 Port Pinouts
Figure B-2 10/100/1000 Port Pinouts
100BASE-FX Ports
The 100BASE-FX ports use MT-RJ connectors, as shown in Figure B-3. The 100BASE-FX ports use 50/125- or 62.5/125-micron multimode fiber-optic cabling.
You can connect a 100BASE-FX port to an SC or ST port on a target device by using one of the MT-RJ fiber-optic patch cables listed in Table B-1. Use the Cisco part numbers in Table B-1 to order the patch cables that you need.
Figure B-3 MT-RJ Connector
Table B-1 MT-RJ Patch Cables for 100BASE-FX Connections
Type
|
Cisco Part Number
|
1-meter, MT-RJ-to-SC multimode cable
|
CAB-MTRJ-SC-MM-1M
|
3-meter, MT-RJ-to-SC multimode cable
|
CAB-MTRJ-SC-MM-3M
|
5-meter, MT-RJ-to-SC multimode cable
|
CAB-MTRJ-SC-MM-5M
|
1-meter, MT-RJ-to-ST multimode cable
|
CAB-MTRJ-ST-MM-1M
|
3-meter, MT-RJ-to-ST multimode cable
|
CAB-MTRJ-ST-MM-3M
|
5-meter, MT-RJ-to-ST multimode cable
|
CAB-MTRJ-ST-MM-5M
|
SFP Module Ports
The Catalyst 3750 switch uses SFP modules for fiber-optic and copper uplink ports. See the Catalyst 3750 release notes for a list of supported SFP modules.
Figure B-4 Fiber-Optic SFP Module LC Connector
Figure B-5 Copper SFP Module RJ-45 Connector
XENPAK Module Ports (Catalyst 3750G-16TD Switch)
The Catalyst 3750G-16TD switch uses XENPAK modules for 10-Gigabit fiber-optic connections to networks. See the Catalyst 3750 release notes for a list of supported XENPAK modules. Fiber-optic XENPAK modules use SC connectors, as shown in Figure B-6.
Figure B-6 Fiber-Optic XENPAK Module SC Connector
Table B-2 lists the XENPAK modules that the Catalyst 3750G-16TD switch supports.
Table B-2 Catalyst 3750G-16TD Switch Supported XENPAK Modules
XENPAK
|
Wavelength
|
Connector and Cable Type
|
Maximum Distance
|
C3-XENPAK-10GB-LR
|
1310 nm
|
SC, SMF
|
6.2 miles (10 km)
|
XENPAK-10GB-ER
|
1550 nm
|
SC, SMF
|
24.85 miles (40 km)
|
C3-XENPAK-10GB-SR
|
850 nm
|
SC; FDDI1 grade MMF SC; OM3 MMF
|
85.3 feet (26 m) 984.25 feet (300 m)
|
For more information about XENPAK modules, see your XENPAK module documentation.
Note
The 10-Gigabit Ethernet XENPAK modules are referred to as 10-Gigabit Ethernet module ports in the software documentation.
Console Port
The console port uses an 8-pin RJ-45 connector, which is described in Table B-4 and Table B-5. The supplied RJ-45-to-DB-9 adapter cable is used to connect the console port of the switch to a console PC. You need to provide a RJ-45-to-DB-25 female DTE adapter if you want to connect the switch console port to a terminal. You can order a kit (part number ACS-DSBUASYN=) containing that adapter from Cisco. For console port and adapter pinout information, see Table B-4 and Table B-5.
Cable and Adapter Specifications
These sections describe the cables and adapters used with Catalyst 3750 switches:
•
SFP Module Cable Specifications
•
Two Twisted-Pair Cable Pinouts
•
Four Twisted-Pair Cable Pinouts for 10/100 Ports
•
Identifying a Crossover Cable
•
Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports
•
Crossover Cable and Adapter Pinouts
SFP Module Cable Specifications
Table B-3 lists the cable specifications for the fiber-optic SFP module connections. Each port must match the wave-length specifications on the other end of the cable, and for reliable communications, the cable must not exceed the required cable length. Copper 1000BASE-T SFP transceivers use standard four twisted-pair, Category 5 or greater cable at lengths up to 328 feet (100 meters).
Table B-3 Fiber-Optic SFP Module Port Cabling Specifications
SFP Module
|
Wavelength (nanometers)
|
Fiber Type
|
Core Size/Cladding Size (micron)
|
Modal Bandwidth (MHz/km) 1
|
Cable Distance
|
100BASE-BX (GLC-FE-100BX-D GLC-FE-100BX-U)
|
1310 TX 1550 RX
|
SMF
|
G.6522
|
—
|
32,810 feet (10 km)
|
100BASE-FX (GLC-GE-100FX)
|
1310
|
MMF
|
50/125 62.5/125
|
500 500
|
6,562 feet (2 km) 6,562 feet (2 km)
|
100BASE-FX (GLC-FE-100FX)
|
1310
|
MMF
|
50/125 62.5/125
|
500 500
|
6,562 feet (2 km) 6,562 feet (2 km)
|
100BASE-LX (100BASE-LX10)
|
1310
|
SMF
|
G.6522
|
—
|
32,810 feet (10 km)
|
1000BASE-BX10-D (GLC-BX-D)
|
1490 TX 1310 RX
|
SMF
|
G.6522
|
—
|
32,810 feet (10 km)
|
1000BASE-BX10-U (GLC-BX-U)
|
1310 TX 1490 RX
|
SMF
|
G.6522
|
—
|
32,810 feet (10 km)
|
1000BASE-SX (GLC-SX-MM)
|
850
|
MMF
|
62.5/125 62.5/125 50/125 50/125
|
160 200 400 500
|
722 feet (220 m) 902 feet (275 m) 1640 feet (500 m) 1804 feet (550 m)
|
1000BASE-LX/LH (GLC-LH-SM)
|
1310
|
MMF3
SMF
|
62.5/125 50/125 50/125 G.6522
|
500 400 500 —
|
1804 feet (550 m) 1804 feet (550 m) 1804 feet (550 m) 32,810 feet (10 km)
|
1000BASE-ZX (GLC-ZX-SM
|
1550
|
SMF
|
G.6522
|
—
|
43.4 to 62 miles (70 to 100 km)4
|
CWDM
|
1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610
|
SMF
|
G.6522
|
—
|
62 miles (100 km)
|
Two Twisted-Pair Cable Pinouts
Figure B-7 and Figure B-8 show the schematics of two twisted-pair cables for 10/100 ports.
Figure B-7 Two Twisted-Pair Straight-Through Cable Schematic
Figure B-8 Two Twisted-Pair Crossover Cable Schematic
Four Twisted-Pair Cable Pinouts for 10/100 Ports
Figure B-9 and Figure B-10 show the schematics of four twisted-pair cables for 10/100/1000 ports.
Figure B-9 Four Twisted-Pair Straight-Through Cable Schematic for 10/100/1000 Ports
Figure B-10 Four Twisted-Pair Crossover Cable Schematic for 10/100/1000 Ports
Identifying a Crossover Cable
To identify a crossover cable, compare the two modular ends of the cable. Hold the cable ends side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should be a different color from the wire connected to the pin on the inside of the right plug. (See Figure B-11.)
Figure B-11 Identifying a Crossover Cable
Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports
Figure B-12 and Figure B-13 show the schematics of four twisted-pair cables for 10/100/1000 ports on Catalyst 3750 switches.
Figure B-12 Four Twisted-Pair Straight-Through Cable Schematic for 10/100/1000 Ports
Figure B-13 Four Twisted-Pair Crossover Cable Schematics for 10/100/1000 and 1000BASE-T SFP Module Ports
Crossover Cable and Adapter Pinouts
This section describes the adapter pinouts.
Table B-4 lists the pinouts for the console port, the RJ-45-to-DB-9 adapter cable, and the console device.
Table B-4 Console Port Signaling Using a DB-9 Adapter
Switch Console Port (DTE)
|
RJ-45-to-DB-9 Terminal Adapter
|
Console Device
|
Signal
|
DB-9 Pin
|
Signal
|
RTS
|
8
|
CTS
|
DTR
|
6
|
DSR
|
TxD
|
2
|
RxD
|
GND
|
5
|
GND
|
GND
|
5
|
GND
|
RxD
|
3
|
TxD
|
DSR
|
4
|
DTR
|
CTS
|
7
|
RTS
|
Table B-5 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the console device.
Note
The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can order a kit (part number ACS-DSBUASYN=) containing this adapter from Cisco.
Table B-5 Console Port Signaling Using a DB-25 Adapter
Switch Console Port (DTE)
|
RJ-45-to-DB-25 Terminal Adapter
|
Console Device
|
Signal
|
DB-25 Pin
|
Signal
|
RTS
|
5
|
CTS
|
DTR
|
6
|
DSR
|
TxD
|
3
|
RxD
|
GND
|
7
|
GND
|
GND
|
7
|
GND
|
RxD
|
2
|
TxD
|
DSR
|
20
|
DTR
|
CTS
|
4
|
RTS
|