Device Configuration Guide for Cisco Security MARS, Release 6.x
eEye REM Devices

Table Of Contents

eEye REM 1.0

Configure eEye REM to Generate Required Data

Add and Configure the eEye REM Device in MARS


eEye REM 1.0


To configure MARS to pull this REM data, you must perform three tasks:

1. Configure eEye REM to correlate the required data, ensuring that the data is current.

2. Add the eEye REM server to MARS using the web interface.

3. Schedule the interval at which the eEye REM server data is pulled by MARS.

This chapter contains the following topics:

Configure eEye REM to Generate Required Data

Add and Configure the eEye REM Device in MARS

Configure eEye REM to Generate Required Data

To configure eEye REM to provide the correct data to MARS, follow these steps:


Step 1 Run command svrnetcn at the DOS prompt on the host where eEye REM 1.0 is installed.

Step 2 In the SQL Server Network Utility dialog box, enable TCP/IP by moving TCP/IP from the Disabled Protocols list to Enabled Protocols list.

Step 3 Click Apply.


Add and Configure the eEye REM Device in MARS

To add the eEye REM device in MARS, follow these steps:


Step 1 Select Admin > System Setup > Security and Monitor Devices > Add.

Step 2 Select Add SW Security apps on a new host or Add SW security apps on existing host from the Device Type list.

Step 3 Enter the device name and IP addresses if adding a new host.

Step 4 Click Apply.

Step 5 Click the Reporting Applications tab.

Step 6 From the Select Application list, select eEye REM 1.0.

Step 7 Click Add.

Step 8 Enter the following information:

Database Name—The name for this database.

Access Port—The default access port is 1433.

Login—The login information for the database.

Password—The password information for the database.

Step 9 Click Submit.

Step 10 Click Apply.

Once you activate this device (click Activate in the web interface), you must define the schedule at which MARS should pull data from it. For more information, see Scheduling Topology Updates, page 1-18.